1970 Beach Ave ROOF20-0004 roof permit ., 't `''''„ ROOF NON SHINGLE PERMIT PERMIT NUMBER
ROOF20-0004
� V, CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD ISSUED: 1/17/2020
w,
ATLANTIC BEACH, FL 32233 EXPIRES: 7/15/2020
•
MUST CALL INSPECTION PHONE'LINE (904)247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: j DESCRIPTION: VALUE OF WORK:
1970 BEACH AVE ROOF NON SHINGLE waterproofing over roof $5200.00
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
169723 1050 NORTH ATLANTIC
BEACH
COMPANY: ADDRESS: CITY: STATE: ZIP:
SCOTT WATERPROOFING p 0 BOX 1748 ORANGE PARK FL 32067
INC.
OWNER: ADDRESS: i CITY: STATE: ZIP:
HOWARD MARK S ET AL 1970 BEACH AVE ATLANTIC BEACH FL 32233-5952
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $80.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL:$124.00
Issued Date: 1/17/2020 1 of 2
ROOF NON SHINGLE PERMIT PERMIT NUMBER
_. CITY OF ATLANTIC BEACH
ROOF20-0004
L_________//:,
800 SEMINOLE ROAD ISSUED: 1/17/2020
.: 0 EXPIRES: 7/15/2020
ATLANTIC BEACH, FL 32233
Issued Date: 1/17/2020 2 of 2
r.' Up"i Building Permit Application OFFICE COPY
dofedl0/9/18
City of Atlantic Beach Building Department **ALL INFORMATION
j, 800 Seminole Road, Atlantic Beach, FL 32233 r.i.
HIGHLIGHTED IN GRAY
CubsIS REQUIRED.
Phone: (904) 247-5826 Email: Building-Dept@coab.us
f� 3aa33 /
Job Address: tq-70 Of 1-"-11 AOf A-t(w--i t ?ck / FI, Permit Number: PipLCvc0 )4
Legal Description 1",1- 5 I Oq- a5 — a,`I E A1c( 1. t ecak`'►t-/- 3R/RE# 161r7a3— 10S-.0
Valuation of Work(Replacement Cost) $ 5'1200,0 0 Heated/Cooled SF Non-Heated/Cooled
• Class of Work: ['New ❑Addition EAlteration ]p Repair ❑Move ❑Demo ❑Pool ❑Window/Door
• Use of existing/proposed structure(s): ElCommercial AResidential
• If an existing structure, is a fire sprinkler system installed?: ❑Yes ;(No
• Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) No
Describe in detail the type of work to be performed:
it(6(44;`•5o.( 1 .‘,s- 7 t .. 4_ ,,517,- S 11,,,,..v„ e.,,41: .
Florida Product Approval# /1)0/'1 (q-0LIail,09 I. IL`1a'i- R.Iformultipleproductsuseproductapprovalform
Property Owner Information11
Name PI 14 t- Ii0 W 4•.rcl rr Address (q 70 et6-Ck I`,e
City 4�'Iw.t:t t.-th State rL Zip 3 ��33 Phone 9O'-I-6 ('I- `NY'
E-Mail
Owner or Agent (If Agent, Power of Attorney or Agency Letter Required)
Contractor Information
Name of Company 510+4- W��er�a�:y ,T+.0 Qualifying Agent Jo KA
•C • )14-4
Address vt, eo( 17 y g City 0 roof r Pok State Zip -72°17
Office Phone 7o`'I- 7 f•-/- 10 & 7 Job Site Contact Number go'-1- '7o S- 75 a 7
State Certification/Registration# Cti- (31Lc' O E-Mail ' .1vt.4c to Slc-t} 1,„c14•-tp^orf> , /c'iii
Architect Name& Phone#
el
Engineer's Name& Phone# L!
Workers Compensation Insurer A►'voc(i C..,, T.^a.r5J*.4 1;0 (t) • OR Exempt❑ Expiration Date , . N
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or install Z o3,ho g
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws reg .:4 Z
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,Sl N I 0 CI 6
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requiremeAsO t
permit,there may be additional restrictions applicable to this property that may be found in the public records of this cou ,StIc U C
there may be additional permits required from other governmental entities such as water management districts, state agel�i5c� T
federal agencies. 0 < O a
O J u' (L)OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance witkta 1- 2.
Z
applicable laws regulating construction and zoning. 0La
It. ;z
n
lii
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAYt- �a- = a
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTE w
Fid,,; 14
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE cc ur.
RECORDING YOUR NOTICE OF COMMENCEMENT. ) c..: p
1 j
(Signature of Owner or Agent)
(Signature of Contractor)
J � t
signed and sworn to(or affirmed)! before me this/ day of Signed and sworn to(or affirmed) before me this i�- y of
20;�i `, �' • • t. - ,' 'Qnhw�� , 3Db.D ,by 714 SW 126 h1-1
-..._ GINDLE �� gq�a�,�""`)D t 11 MI
f rig ram�iw.�,-
f.P ` MY COMMISSION a9 GG '.178,' tc,1 t� N tory) �� I ; ti'. :''�j atu .•'Il"iv'.#GG 042684
r •+` 6,'2023I,- IT '#` EXPIRES:October 27,2020
;vim•^`• EXPIRES:October =v�'i 'd-
fO`F`�'' Bonded Thtu Notary Pubic Ur>denvtitero .,Ffi,,�Pr Bonded Thru Notary Public Urttlohvritars
I t rei surraily 1/,,,,,,,,API( : - [ ] Personally Known OR —----
[
[ ] Produced Identification /� c� [L}-Produced Identification
Type of Identification: V 1 4-S00-3 :11�0 8 O Type of Identification: S:s-L 6 t k t1,L,t S r L .r)S-'C
OFFICE COPY
1 .�1
Since 1955
GACO WESTERN
GacoFlex S-20
Product Data Sheet
ER
ENERGYPAR
PARTNER
COOL ROOF
RATING COUNCIL.
GACOFLEX S-20
SINGLE COMPONENT SOLVENTLESS
SILICONE COATING
DESCRIPTION: GacoFlex S-20 Series are single component elastomeric waterproofing moisture curing
silicone coatings. GacoFlex S-20 Series are petroleum-free coatings.
Standard specification for liquid applied silicone coating used in spray polyurethane foam
roofing.
USAGE: GacoFlex S-20 is designed as a protective coating for spray-in-place polyurethane foam,
metal, concrete,wood, built-up roofing and most single ply's.
COLOR: S-2000 white, S-2022 medium gray, S-2029 dark gray and S-2048 tan (special order).
1.11111111111111118
APPLIED PRODUCT DATA
WEATHERABILITY: Excellent durability,color stability and chalk resistance.
CHEMICAL
RESISTANCE: Excellent solvent and chemical resistance.
S-2000 Immersed in Water(x)150°F(66°C)
for 1 year per ASTM D-471:
TENSILE: ASTM D-412
Strength: 550 10 psi Strength: 463 psi
(3.79* .07 MPa) (3.19MPa)
Elongation: 150%± 10 Elongation: 125%
Permanent Set At Break: Approx. 1% Permanent Set At Break: 0%
TEAR RESISTANCE: ASTM D-624 DIE C
Lb./In. 21 pli (3.8 kg(f)/cm) 11 pli(2.0 kg(f)/cm)
HARDNESS: ASTM D-2240 55 Shore A 56 Shore A
WATER VAPOR ASTM E-96 5.3 perms
PERMEABILITY: Procedure B at 0.5 mm(20 mils)thickness� 10%
Minimum permeance requirement is 2.5 U.S. perms
www.gaco.com I 800.456.4226 I 800.248.8679
L � '
xEnzinimec
GACO WES I ERN
ADHESION: Excellent adhesion to polyurethane foam.
FLAMMABILITY: ASTM E108 Class A
REFLECTANCE: ASTM C-1549 0.88
S-2000 White
EMITTANCE: ASTM C-1371 0.87
S-2000 White
PACKAGED PRODUCT DATA
COVERAGE: Sq. Ft./Gal./Mil 1524 (37.42 m2/L/.02mm)
SOLIDS: Weight: Method 4041 96.5%± 1%
Fed. Std. 141
Volume: 95% ± 1%
V.O.0 Volatile organic compounds content is 48 grams per liter.
FLASH POINT: ASTM D-56, TCC Above 179°F(82°C)
STORAGE STABILITY: One year from date of manufacture when stored in sealed containers below 75°F(24°C).
CLEANER: GacoFlex T-5135/T-5110 VOC compliant thinner.
APPLICATION
PRIMER: None normally required.
MIXING: Mix before application to assure uniform color and consistency.
APPLICATION: Apply by brush or roller as received. For spray application, use as received. Consult Gaco
Western's Silicone Spray Guide SG-Silicone for more information.
For cold weather application, keep material stored above 65°F (18°C). Recoat time is between 4
to 48 hours. Longer recoat times will result in poor intercoat adhesion and delamination.
CLEAN-UP: Clean spray equipment with GacoFlex T-5135 / T-5110 VOC compliant thinner.
Recirculate through lines and gun until residual GacoFlex is removed.
CURE: Applied coating will cure in 1 to 4 hours depending on temperature and humidity.
CAUTION: GacoFlex S-20 is considered combustible. Keep away from heat, sparks and open flame.
Avoid prolonged breathing of vapors and prolonged or repeated skin contact. Use only
with adequate ventilation.
www.gaco.com I 800.456.4226 I 800.248.8679
G a co Western
SINCE 1 9 5 5
SPRAY GUIDE: GW 6-5 SG-Silicone
August 2013
Supersedes 10/11
GACOFLEX SILICONE COATING
SPRAY GUIDE
This guide covers handling and airless spray application of GacoFlex Silicone single component, silicone
coatings. GacoFlex Silicone polymerizes through chemical reaction with air borne moisture yielding tough,
waterproof, weather-resistant elastomeric films. Airless spray is an effective method of application particularly on
large areas and irregular or vertical surfaces. Air-atomized application is not recommended.
Personnel using this product should familiarize themselves with procedures for personal safety, workplace
precautions, and equipment operation. Refer to Product Data Sheet and Material Safety Data Sheet for product
information. Refer to manufacturer's instructions for spray equipment operation, maintenance and safety.
A. SAFETY EQUIPMENT AND VENTILATION
Some GacoFlex Silicone may contain flammable solvent. Spray application creates finely atomized particles
and vapors, which dictate specific procedures to minimize health and safety risks.
PROTECTIVE EQUIPMENT
• Use supplied air-breathing apparatus with full-face mask or hood during any spray application unless
monitoring demonstrates chemical exposure below OSHA permissible limits.
• A properly fitted respirator(NIOSH/MSHA) is recommended during spray application.
• Chemical protective clothing
• Chemical protective gloves
INDOOR SPRAYING PRECAUTIONS
• Isolate the area to be sprayed from the rest of structure.
• GacoFlex Silicone may contain flammable solvents, which evaporate into the air during application
and cure cycle. Follow Gaco Western Fire and Explosion Prevention instructions found in Gaco
Western Safety and Storage document.
• Spray only in well-ventilated areas.
• Explosion-proof equipment, capable of keeping vapor concentration below the LEL, must be used.
The environment must be monitored to assure compliance.
• Air from spray area must be exhausted outdoors in a manner that prevents return through windows,
doors or intake vents.
• Keep spectators and other personnel away from spray area.
• Be sure to take proper precautions to not spray over unprotected energized lighting or electrical
outlets. Doing so could be a fire hazard. Electrical wiring and conduit can be sprayed on as long as
open energized circuits are protected.
OUTDOOR SPRAYING PRECAUTIONS
• Rope off the area within 150 feet(45.72 meters) of spray area.
• Seal off ventilation intakes within the affected area.
• Use windbreaks, where necessary to confine spray mist and avoid damage to nearby surfaces due to
overspray or drift.
• Keep spectators and personnel away from spray area.
• Be sure to take proper precautions to not spray over unprotected energized lighting or electrical
outlets. Doing so could be a fire hazard. Electrical wiring and conduit can be sprayed on as long as
open energized circuits are protected.
Made in the USA • gaco.com • 800.331.0196
GW 6-5 SG-Silicone
Page 2
B. STORAGE AND HANDLING
STORAGE
• Keep containers tightly closed. Store in a dry, cool place away from heat, sparks, open flames and
moisture.
• For cold weather application, keep material stored above 65°F (18°C).
• Hot weather application will result in shortened pot life. Store materials out of sun and below 80°F
(26°C).
HANDLING
• Each GacoFlex Silicone coating product is unique. Components of various products cannot be
intermixed. Separate products at the jobsite to avoid mixing errors.
• Protect from freezing during shipping and storage.
MIXING
• Settling or separation may occur from storage
• Mix material before using to assure uniform consistency. Use folding blade-type mixer for closed
head drums
• Ground container and equipment to prevent accumulation of static charge
• Place a small amount of GacoFlex T5135 Silicone Solvent or T5110 VOC Compliant Silicone Solvent
on top of mixed material to prevent formation of"skin."
THINNING
• Thinning GacoFlex Silicone is not recommended.
• GacoFlex T5135 or T5110 VOC Compliant Silicone Solvents are recommended to clean equipment.
Only use Gaco Western Silicone Solvents. Other solvents may contain alcohol or other contaminants,
which will adversely affect coating characteristics, resulting in decreased physical properties and
weather resistance or potential damage to spray equipment.
C. SPRAY EQUIPMENT
Airless spray equipment generates very high fluid pressure. Spray equipment must be properly maintained
and operated. Any misuse of spray equipment or accessories (such as over-pressurizing, modified parts, or
worn or damaged parts) can result in serious bodily injury, fire, explosion or property damage. Read and
follow the equipment manufacturer's instructions and recommendations.
AIRLESS SPRAY PUMP
Airless spray pump must have 5,950 psi minimum output pressure rating and adequate delivery volume to
support the spray tip orifice gallons per minute (gpm) rating. High-pressure airless sprayers with a higher
maximum pressure capability will allow the use of spray hose lengths greater than 250 feet(76.2 meters).
Graco®Airless Sprayers:
Part# Name Rated PSI GPM
XM6DH4/ X-70 7,000 1.8
L180C3
Airless sprayers not listed have not been evaluated. The preceding information can be used as a reference
for assembling an alternative equipment system.
SPRAYER SUPPLY
• Transfer pump is preferred to assure positive supply of coating to the airless pump. 5:1 fluid to air
ratio transfer pump of divorced design will supply coating from drums without cavitation and resulting
premature packing wear.
Made in the USA • gaco.com • 800.331.0196
GW 6-5 SG-Silicone
Page 3
AIRLESS SPRAY HOSE
Airless spray hose must be a grounded nylon tube paint hose, rated for use at maximum pressure produced
by the spray pump. Use only electrically grounded hose designed for paint and solvent. Never exceed
maximum working pressure of hose or fittings.
NOTE: To help prevent hose plugging problems, use only a moisture resistant hose when spraying.
• The larger the hose diameter, the less pressure drop will occur between the airless pump and spray gun.
There is 2.5 times less pressure drop with a 'h inch (1.27cm) i.d. hose, compared to 3/8 inch (0.95 cm)
i.d. hose.
• Maximum hose length can be as long as 362 feet (110.3 m), including whip hose. Hose will consist of a
250 ft., 3/4" inch hose and 50 feet of a 1/2" inch hose.
• A whip hose, up to 12 feet in length, and gun swivel, are recommended to control spray and reduce
operator fatigue. In some conditions, the whip hose may cause unsatisfactory spray patterns. Conditions
that may cause this are colder temperatures or too long a spray hose.
• Best performance can be achieved if any fittings that could restrict flow in the pump or spray hose are
replaced. For example, an inline filter.
SPRAY TIP SELECTION
Spray tip selection is based upon the material delivery volume and spray pattern desired.
• The orifice size of a spray tip determines material delivery volume. The larger the orifice, the lower
the pressure output which could result in unsatisfactory spray pattern. The fan width of a spray
tip determines the pattern size. The higher the temp of the product combined with a shorter hose
and more pressure at the rig could all allow for a bigger spray tip and more output.
• Recommended tip size is 0.031"with a 631 tip being ideal for spraying roofs. (Depending on hose
length, roof height, temperature, etc, the tip size could vary from 0.029 to 0.035 (629—635))
• Filters should be removed.
• Spray application rate is typically from 0.75 to 3 gallons per 100 sq. ft., depending on the substrate
and specification. Please see Gaco Western specification for recommended application rates.
FILTERS
• Filters should not be used in the gun or lowers.
SPRAY APPLICATION RATE
• GacoFlex Silicone applied at 1.5 gallons per 100 sq. ft. provides 22 dry mils More coating may be
required, depending on surface texture, as well as air loss, spills and waste. A one-coat application is
typically required for a 22 dry mil spec. Select a spray tip that is within the performance capacity of
the airless spray pump. The larger the spray tip, the greater the pressure drop. Long hose length and
cold material will decrease material delivery volume and fluid pressure at the spray tip
• If the spray pattern has fingers or pulsates, change spray tips to reduce the size of the spray orifice.
This will decrease material delivery volume and increase pressure.
D. APPLICATION
CLIMATIC CONDITIONS
Rain, fog, dew, and frost may react adversely, affecting adhesion and physical properties of coating. Do not
apply if any of these conditions exist or will exist immediately after application. The substrate must be dry,
clean and sound at the time of application.
At temperatures below 65°F, store and maintain material temperature at 65°F or above in the container.
Application is possible with ambient temperatures down to 33°F. At temperatures above 85°F, reduce the
application rate on vertical or irregular sufaces to prevent sags or runs.
DO NOT
• Do not apply if ambient, material or substrate temperatures are below 33°F (0.5°C).
• Do not apply by airless spray when air temperature is within 5°F (2.8°C) of the dew point.
Made in the USA • gaco.com • 800.331.0196
"GW 6-5 SG-Silicone
Page 4
SPRAYING TECHNIQUE
Hold the spray gun perpendicular to the surface at a distance of 12 to 18 inches(30.5 to 45.7 cm). While
triggering the spray gun, move it at a rate to produce the desired coating wet mil thickness without thin spots
or"holidays." Spray technique should include a "half lap" technique where each spray pass is overlapped
50% for uniform coverage. Check applied film thickness using a wet mil gauge.
Use the lowest fluid pressure that will provide a uniform spray pattern without fingering. When greater material
coverage is desired, use a larger spray tip orifice size instead of increasing pressure. Too high of pressure
could cause excessive overspray.
Spraying must be organized to maintain constant material flow through airless spray hoses. Coating viscosity
will increase rapidly in airless spray hoses if the hoses are exposed to direct sun or high temperatures.
Plan the application sequence to provide for best production and limited down time. Rotate spray mechanics
as needed to allow for continuous production. Material must be flushed from equipment when down time
exceeds pot life.
Allow a minimum of 2 hours between coats for cure and solvent evaporation. Refer to Product Data Sheet for
specific information for specific conditions.
CLEAN-UP
• GacoFlex T5135 Silicone Solvent or T5110 VOC Compliant Silicone Solvent is recommended to clean
equipment. Only use Gaco Western Silicone Solvents. Other solvents may contain alcohol or other
contaminants, which will adversely affect coating characteristics, resulting in decreased physical
properties and weather resistance or potential damage to spray equipment.
• Troubleshooting information presented below applies to all Gaco Silicones. Product Data Sheets and
manufacturer's equipment operation manual should be referred to for additional information.
Condition Areas to Check Corrective Action
Poor spray pattern • Too large or worn spray tip ✓ Replace with new or smaller tip
• Low fluid pressure ✓ Increase pump pressure
• Cold material ✓ Warm to above 60°F (16°C)
Pulsating spray pattern • Too large or worn spray tip ✓ Replace with new or smaller tip
• Inadequate material supply ✓ Check suction hose/transfer pump
• Spray pump ball check obstructed ✓ Check and clear
• Inadequate compressed air ✓ Provide more air or use smaller tip
Sags/runs on vertical • Too much material per coat ✓ Reduce application rate per coat
(more coats may be required)
Runs off high on spray foam • Material or substrate too warm ✓ Reduce application rate or wait for
cooler conditions
Foamy or pin holed coating • Wet substrate ✓ Wait for surface to dry
• High humidity near dew point ✓ Wait for acceptable conditions
• Rain/dew on uncured coating ✓ Wait for acceptable conditions
Made in the USA • gaco.com • 800.331.0196
+1 I
MIAMI-DADE COUNTY
MIAM PRODUCT CONTROL SECTION
COUNTY 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Gaco Western LLC
1245 Chapman drive
Waukesha,WI 53186
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GACO WESTERN ROOF COATING SYSTEMS
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city and state of
manufacturing facility,and following statement: "Miami-Dade County Product Control Approved",unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 17-0329.08 and consists of pages 1 through 5.
The submitted documentation was reviewed by Hamley Pacheco,P.E.
MANMADE COUNTY
NOA No.: 18-0424.08
`—
Expiration Date:05/31/23
Approval Date:05/31/18
Page 1 of 5
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Cement-Adhesive-Coatings
Materials: Elastomeric
SCOPE:
This approves GACO WESTERN ROOF COATING SYSTEMS as a roof maintenance coatings
manufactured by Gaco Western LLC, as described in this Notice of Acceptance. This product has been
designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the
Florida Building Code.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials GWI-045-02-01 ASTM D6083/Fed Spec TT-C-555B 07/21/17
Technologies, LLC GWI-042-02-01 ASTM D6694/Fed Spec TT-C-555B 01/09/18
GWI-044-02-01 ASTM D6694/Fed Spec TT-C-555B 01/09/18
GWI-043-02-01 ASTM D6694/Fed Spec TT-C-555B 01/09/18
GW I-046-02-01 ASTM D93, D1644, D1475 & D2196 05/24/17
Underwriters Laboratories R5663 UL 790 02/08/16
Factory Mutual Research 3023644 4470 02/02/07
Corp.
MANUFACTURING LOCATION:
1. Waukesha, WI
NOA No.: 18-0424.08
MWMFOADE COUNTY p
APPROVED Expiration Date:05/31/23
Approval Date: 05/31/18
Page 2 of 5
4
PHYSICAL PROPERTIES OF COMPONENTS
Trade names: A3100R Acrylic Top Coat
Thickness: For application over spray polyurethane foam system apply a base coat at a
minimum rate of 1.13 ga1/100 ft2, an intermediate coat at a minimum rate of 1.13
gal/100 ft2, and a top coat at a minimum rate of 1.13 gal/100 ft2.
For application of a recover coating over an existing acrylic roof apply a base
coat at a minimum rate of 1 gal/100 ft2, and a top coat at a minimum rate of
1 gal/100 ft2.
Specifications: ASTM D 6083
Description: An acrylic white elastomeric quick set coating membrane applied to; spray
polyurethane foam roof systems and a recover of any existing acrylic roof.
Container Size: 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
Trade names: S 1000 Top Coat
Thickness: For application over spray polyurethane foam system apply a base coat at a
minimum rate of 1.1 gal/100 ft and a top coat at a minimum rate of 1.1 gal/100
ft2.
For application of a recover coating over an existing silicone roof apply a base
coat at a minimum rate of 1.1 gal/100 ft2, and a top coat at a minimum rate of
1.1 gaU100 ft2.
Specifications: ASTM D 6694
Description: A single component, air dried, silicone-based rubber elastomeric membrane
coating that is brush,roller or spray-applied. To be applied to spray polyurethane
foam roof systems and as a recover of any existing silicone roof coatings.
Container Size: 5 and 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
NOA No.: 18-0424.08
MIAM_OADECOUNTY Expiration Date:05/31/23
Approval Date: 05/31/18
Page 3 of 5
Trade names: S-2000 Solventless Silicone Basecoat/Top Coat
Thickness: For all applications apply 2 coats; a base coat at a minimum rate of.75 gal/1OO ft
and a top coat at a minimum rate of.75 gal/100 ft2.
• Spray Polyurethane Foam Roof Systems
• Acrylic Coatings(in conjunction with GacoFlex E5320)
• Galvanized Metal Roofs(in conjunction with GacoFlex E5320)
• Smooth Built Up Roof Systems (in conjunction with GacoFlex E5320)
• EPDM Single Ply Roof Systems (in conjunction with GacoFlex E5320)
• PVC Single Ply Roof Systems (in conjunction with GacoFlex E5320)
Specifications: ASTM D 6694
Description: A single component, moisture cured, silicone-based rubber elastomeric
membrane coating that is brush, roller or spray-applied to the roof covers listed
above.
Container Size: 5 and 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
Trade names: S 1600 Base Coat/Top Coat
Thickness: For application over spray polyurethane foam system apply a base coat at a
minimum rate of 1.1 gal/100 ft and a top coat at a minimum rate of 1 gal/100 ft2.
For application of a recover coating over an existing silicone roof apply a base
coat at a minimum rate of 1 gal/100 ft2, and a top coat at a minimum rate of
1 gal/100 ft2.
Specifications: ASTM D 6694
Description: A single component, moisture cured, silicone-based rubber elastomeric
membrane coating that is brush,roller or spray-applied. To be applied to spray
polyurethane foam roof systems, galvanized metal, smooth surfaced built-up
(BUR)roofing,acrylic coating and any existing silicone roof coating..
Container Size: 1, 5 and 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
NOA No.: 18-0424.08
MANMADE COUNTY
Expiration Date: 05/31/23
APPROVED p
Approval Date: 05/31/18
Page 4 of 5
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire rating of this product.
2. GACO WESTERN ROOF COATING SYSTEM shall not be applied in inclement weather
conditions.
3. GACO WESTERN ROOF COATING SYSTEM shall not be applied over asphaltic shingles,
metal shingles, fiber-cement shingles,quarry slate, cement or clay roofing tile, or wood shingles
or shakes.
4. The products listed herein are components of roof assemblies and are approved for use with roof
assemblies that list any of the products listed herein as part of their roof assemblies Notice of
Acceptance. For applications over existing single ply, smooth or granulated BUR systems. Refer
applicable building code for requirements.
5. All products listed herein shall have an unannounced follow-up quality control program from an
approved listing agency. Follow up test results shall be made available to Miami-Dade County
Product Control upon request.
6. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear
the imprint or identifiable marking of the manufacturer's name or logo and following statement:
"Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control
Seal as shown below.
NIAP4 ADE COUNTY
APDAOVED
7. Change in materials,use,or manufacture of any of the products listed herein shall be cause for
termination of this Notice of Acceptance.
8. GACO WESTERN ROOF COATING SYSTEM shall only be applied by a factory trained and
certified applicators.
9. GACO WESTERN ROOF COATING SYSTEM shall be applied in accordance with
manufacturer's published application instructions.
END OF THIS ACCEPTANCE
NOA No.: 18-0424.08
NAP= Expiration Date:05/31/23
Approval Date:05/31/18
Page 5 of 5