Loading...
583 Coastal Oak Ln ROW19-0045 Comcast :.S'.. RIGHT OF WAY PERMIT PERMIT NUMBER °- ' ROW19-0045 ; �j CITY OF ATLANTIC BEACH ISSUED: 12/31/2019 800 SEMINOLE ROAD ATLANTIC BEACH. FL 32233 EXPIRES: 3/30/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 583 COASTAL OAK LN RIGHT OF WAY SINGLE OR TWO UG CATV- COM CAST $0.00 FAMILY RIGHT OF WAY TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 169505 1735 ATLANTIC BEACH COUNTRY CLUB UNIT 02 COMPANY: ADDRESS: CITY: STATE: ZIP: COMCAST OWNER: I ADDRESS: CITY: STATE: ZIP: PROCOIN LLC 2529 BAY POINTE CT WESTON FL 33327 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells, Inc.,Republic Services,Donovan Dumpsters, Phillips Containers,JDog/Dennis Junk Removal,All American Roll Off,WCA Waste Corporation). Container cannot be placed on City right-of-way. Issued Date: 12/31/2019 1 of 2 rS"'`'% RIGHT OF WAY PERMIT PERMIT NUMBER ". '# ;, ;T,-;:iii,,,, }r , i ROW19-0045 CITY OF ATLANTIC BEACH ISSUED: 12/31/2019 800 SEMINOLE ROAD oi.119'.• ATLANTIC BEACH. FL 32233 EXPIRES: 3/30/2020 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 4 PUBLIC WORKS OTHER PUBLIC WORKS CONDITION INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 5 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 6 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL I Notes: 7 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. I DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date: 12/31/2019 2 of 2 '!� Revision Request/Correction to Comments **ALL INFORMATION .:}rfid0"---' HIGHLIGHTED IN ''' 1 City of Atlantic Beach Building Department GRAY IS REQUIRED. i 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: OVJ ( l -oo4S X Revision to Issued Permit OR ,_ Corrections to Comments Date: 1 I C/ ClZ r Project Address: D COQ4Q( 0 CZ,:` Contractor/Contact Name: cs:.) AA°.P& l Contact Phone: '3 z..0 --Z9. Z-q 7 ( Email: . Description of Proposed Revision/Corrections: kPc- u 02t` I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Will proposed revision/corrections add additional square footage to original submittal? C No ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? ❑No ❑*yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) /Approved Approved [ I Denied I Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments ` Department Review Required: Building , :‘, i'2m,w�� Planning&Zoning Reviewed By Tree Administrator CeEi'�l'E ,P. . is Works /-/C blic tilitie JAN 10 2020 -,22 (-) ,., Pu.lic Safety Date Fire Services BY: Updated 10/17/18 Revision Request/Correction to Comments **ALL INFORMATION 0,%*,Ali, HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. v 800 Seminole Rd, Atlantic Beach, FL 32233 o fi'r Phone: (904) 247-5826 Email: Building-Dept@coab.usPERMIT#:RCM l -0v4E. Revision to Issued Permit OR A. Corrections to Comments Date: 1 k C) 0 r Project Address: ' LOQ Z i"Q,( 0 GL Contractor/Contact Name: 0 (VAC Pk& t Contact Phone: 3ZG `"Zci Z-49 7 ( Email: Description of Proposed Revision/Corrections: C )ct-( K LL3c2 � I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Will proposed revision/corrections add additional square footage to original submittal? ❑No ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? ❑No ❑*yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: 7 (Office Use Only) Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ 25-SSI Revision/Plan Review Comments Department Review Required: Building _- t -*"....i.: :::— Planning&Zoning Reviewed By Tree Administrator P. • lc Works ubli tilitie" /-1(0 – ze Pu•I is Safety Date Fire Services Updated 10/17/18 t, q ir4 ▪S "" RIGHT-OF-WAY / EASEMENT PERMIT Roc ) /rPermit# Issued by the City of Atlantic Beach t q - 004S PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 583 COASTAL OAK LN ATLANTIC BEACH FL 32233 phone 405-314-9079 Permittee AFG ON BEHALF OF COMCAST Email SANDERS@FIBERCOREGROUP.COM Requesting Permission to Construct PROPOSED UG CATV FACILITIES, 304' COAX FOR REPAIR Location(Reference to Cross-Street)COASTAL OAK LN & MARITIME OAK DR • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction, repair, improvement,maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation-Standards and be performed under the supervision of (Project Superintendent) with Company Name Phone • All materials and equipment shall be subject to inspection by the Director of Public Wo4P. 1 0 2020 • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent,survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder, and the holder will, at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Publ. orks shall be notified twenty-four(24)hours prior to starting work and again i 'atel completion. ] Date f ' r O o'0 Permittee(si ned ' presence of Notary Public) STATE OF FLORIDA, COUNTY OF DUVAL The foregoing instrument was acknowledged this (J day of -00(\A) Q.(1/4-( ,20 10 , by D00/i c-e\t;'O i ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. 2d149 Personally Known SigItature of tary Pub 1 , tate o ��F�� t?' luced Identification(Type) "F"L 0C_ I �'A N Notary Public.State of Florida ,,.—„ Commission#GG 38797 �w`' My comm.expires Oct.16.2020 PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: /— /Co — 20 Application#: 2OL) / / '4 5- Project Project Address: 5- 6),q-57-4-C Dj9, . LJ ) Check Box Check APPLICATION TRACKING COMMENTS to Add / Box to Comment Print Underground Avoid damage to underground water and sewer utilities. Verify vertical and Water Sewer horizontal location of utilities. Hand dig if necessary. If field coordination is m Ci Utilities needed, call 247-5878. Meter Sewer Boxes Ensure all meter boxes, sewer cleanouts and valve covers are set to grade 0 0 Cleanout and visible. A sewer cleanout must be installed at the property line. Cleanout must be RT1 Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade 0 0 Cleanout and visible. A reduced pressure zone backflow preventer must be installed if irrigation will RPZ Backflow be provided or if there is a private well on the property. Backflow preventer ❑ must be tested by a certified tester and a copy of the results sent to Public Utilities. Plans note the building will be unsprinkled. If plans change, any fire line Sensus installed must be metered with a Sensus touch-read meter in a properly sized Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer 0 0 Meter must be tested by a certified tester and a copy of the results sent to Public Utilities. Fire Sprinkler If fire sprinkler system is provided, call 247-5878 for backflow requirements. Backflow 0 0 At a minimum, will require a double check backflow preventer. Requirement Fire Line Fire lines must be metered with a Sensus touch-read meter. Meters larger Meter than 2" must be installed in a vault as noted in JEA specifications. ❑ ❑ Utility Map See attached Utility Map. Disconnect &Cap Disconnect and cap water and sewer lines. 0 0 Inspection MUST call the Inspection Line at 247-5814 to request an inspection of the Prior disconnected and capped water and sewer lines PRIOR to demolition. ❑ ❑ Utility All water& sewer utility connections must be inspected prior to cover up. Inspections Please call the inspection line at 247-5814 to schedule inspections 24 hours in ❑ 0 advance. System All fees must be paid for water& sewer connections before meters will be set. Development Please call the finance department customer service line 247-5816 to 0 0 Fees coordinate payment of fees. 0 0 .... - -. ‘,.., *-1'. • .00000,00„:00e, ,,,-' ..,.,•,..-.-....,,,, ,..,4, ''',.'''''' . . .L,,,.....,' ..„...., ...., .....„.....„ - \ s....,...5.,.......,-, . . . . . i— ' ' 414° 10,A '''''‘4'.•S ,•• ..• . •••, ,I- :••• . 1•,,, .., •Allk401‘.4 , • -• '•'• A__-- _ . _-.-... cs ': ,- - t,4 •1, .- -- -••;-- ' '4 r ..,:!.... ,,..1...!...0.,....., :• ,i . ,., fig ii et w' 46 — ,. ''''''''•••,", 1 -'.-' ',:dit-, ...,,-' ' 4. ,*44 11115"''it ., •'' .,..'Z''''',,,',.,::.' WO , .... ,i• - w w w w w w rairmilis • - '- -,' ,%if r_ ...,..-,,,-..-,'74,,: -..',, =_•••11•4* . id , • 1 - ,H• i • t 1' . , -,,,,• -.. • . .,• ...•,c. A crt.:,..„ _ o -- , 4,...f . ir rib 5-4 ''''-!,„,,,"-- • ,J / / 4. 4 ••,‘ --4 ,.'4„.,3 .,1 4''''r "' -,.',,,„,...,. ,. ' •,,,,,,. ., 1 • 4•1 . _.,,0 -., —. --- CP -4 1 ,,., r• ; -.' -- I / .,...' .*1 . • .,.. . ..., . k 0- / •.: , .4• . C9 ' • / .".;----:,--. ",',-''''-".--...-:'.-.',•:,---..," --•'.. - -177-7„ - *." -7--- --'"-- - -., Alrfr .. 4k. i'7• ."'" litliit.amext.it , # ,,.,.',4,.0..• ' . .,, ..._. . , .....„ „, ; il i ,i.,":-`-'--= 14'.* a '_,.---..,0 s-r.-,..., -_;--.” , -,-', - •--.., ..1 -...„._ • i --,'-; .- ,, . • , _ ' .. . H H „ ' _ ,„,,. , , ,, „ .,. •c,,,,-.A.--.el'''. - .. ..,. . . '.4-,,r.,4.-.',.'.''' . .•.,-.---.- - ',...,. . .-............:-_,,.,' '......; 1.,......,.- .-., 0 , . 11 ..; .,. ;..:44aL , , .... .. ... .,,. . . ............. , . ..... . . ,, . ..„...:- .. , IL, .. . . . i ..,,,"( ',.--. .- :S... S . /-,,,,,-.„,. _ . ,.._, 4....0,. ; ,„..3.-. .,.,.,..,-,...„,.-,.......,.-7,,,,,.. „.,.-.,:.-i„,.!,-.!,-...,,,..-:,-.,-„-.L.,..i,.r -,...---,.*.,. ,,"2•7 .....-: „...... .,, .,' •.('''','i' -.''''' ''''t,i:rA.%.4 . . '-,,..;,''':.-',,,-*`ii''''.7"•-,,•,-"-'""t"7"•144.41'"4- -•-•''''*'..-- 7 ... ....,.... „:„.., , /r • ' . ' :.,. • ' ''' ..,' '4'.',Ik'',:p 4....,...4..',',''S[''',.,..*,.''''''.'.;--.T!-',C'1,'"I'''II.-,,'","'-' '' '' ' '- 4 Iii -' 1 .,. --, '-''',.---' -,- '';'- ' - :.'r •Ye--,4-,'"-_,'-',--",:-:-,,'-, ,,:,;;;;47, :!,--,,,..,,,,T4.,%,.c., -:',,, ' '' ,-. , ' •- :,...,.'--- -..,7,....-...,,, 44` .- -,,,i'nec.,,,,;,;."•:-.k,'-',-"-,-'''•, ,,'.:;P41.-:`",','..,,,-;•.i...J-,..-,,,:.,„,,,.....,,, ,,_.:: - ' -',:-.'',;.- '-'• . '-':. -.'„''., s.-.t.ii---0,;'-i-i;--flPItzsi,:::::::",r)'::'?'Vi: "z;7::-.-''=.'; :- - _ --.4,:-., :' .-,..,,`;--,,,..:-;'''' '-:-----1-1•7''''''''''''''"'—'-`-'4'•.' '''' ..,t''. ' , -. --...:-',,-: ' '2' 10 , ',1 4, . 1, 4". -, --_....,-,... --.:.- .,--T- - , .4 . I 3 --- ._ ''-' $1.- - ,., ...' . ' . . . ..,_ . ...... .... . • . . .. ,... \ , - ''-3,1).0dtkr,._ — i 4 Gindlesperger,Toni From: Gindlesperger,Toni Sent: Friday,January 10, 2020 8:16 AM To: 'Misty McElroy' Subject: RE: COAB PERMIT REQUEST - 583 COASTAL OAK LN ATLANTIC BEACH FL 32233 Good Morning, Either way would be fine. We would need a revision form r Jo copies of everything brought in to the office. Or two copies of everything and a note that the original permit (. eled. Thank you, Toni Gindlesperger Building Permit Technician City of Atlantic Beach 904-247-5800 ext 9 BUILDING-DEPT@COAB.US From: Misty McElroy [mailto:misty@fibercoregroup.com] Sent:Thursday,January 9, 2020 3:43 PM To:Jennifer Sanders<sanders@fibercoregroup.com> Cc: Gindlesperger,Toni <tgin@coab.us>; Building, Dept<Bui'ding-Dept@coab.us>; David McElroy <david@fibercoregroup.com> Subject: Re: COAB PERMIT REQUEST- 583 COASTAL OAK !N ATLANTIC BEACH FL 32233 Hello, We are just checking back in with you on this. Do }ou think a revision on this permit would be an option? Thank you, Misty McElroy Director of Operations Cell (32o) 292-4971 On Tue, Jan 7, 2020 at 7:14 AM Jennifer Sanders <sanc ers@fibercoregroup.com> wrote: Good morning Toni. Comcast has changed the route for this approved permit slightly. This is a customer- affecting repair. Do you need a new application delivered to your office? Or are the attached plans sufficient? Thank you for your help, Jennifer Sanders,Project Manager (405)314-9079 cell On Thu,Jan 2, 2020 at 8:02 AM Misty McElroy<misty@fibercoregroup.com>wrote: Hello Toni, Can you please assist me with an ETA on this permit approval? Thank you, Misty McElroy I Director of Operations Cell (320) 292-4971 On Wed, Dec 18, 2019 at 7:15 AM Jennifer Sanders <sanders(c,fibercoregroup.com> wrote: Good morning Toni. This permit request will be hand delivered to your office today. The work is for customer-affecting repair work. If there is any way it can be expedited, that would be great. Please let me know if you have any questions. Have a great day. Jennifer Sanders,Project Manager (405)314-9079 cell 2 COMCAST PERMIT REQUEST FOR 583 COASTAL OAK LN, ATLANTIC BEACH, FL 32233 THESE PLANS WERE PREPARED UNDER THE RESPONSIBLE CHARGE OF COMCAST AND ARE EXEMPT FROM Tl�-IE SIGNING AND SEALING REQUIREMENT"S PRESCRIBED IN SECTION 471 OF THE FLORIDA STATUTES ESCAMBIAHOLMES PROPOSED AERIAL FOOTAGE 0' PROPOSED UG CATV/FIBER 304' TOTAL FOOTAGE COUNTY SANTA TOTAL PROPOSED BORES JACKSON TOTAL PROPOSED PEDS 3 TOTAL PROPOSED BORE PITS ROSA g h COUNTY COUNTY r FIBER WA'T'ER COUNTY OKALOO } t COUNTY TRANSFORMER POLE RISER POLE j� CULVERT NASSAU COUNTY WALTON WASHINGTO GADSDEN —SEWER----- RIGHT OF WAY ---------- COUNTY BORE PIT COUNTY COUNTY COUNTY LEON HAMILTON COUNTY MADISON COUNTY C t,'i '21131 11 .��L G.aF �p MS..,��•m>x. +MM'S ^nxr.> "'''azse ZSk. `Y CALHOUN" COUNTY OatsYY ®vi.. COUNTY LEON LEONEE SUWANN SUWANBAKER COUNTY COUNTY LIBERTY WAKULLA COUNTY VICINITY MAP COUNTY COUNTY 001X^ TAYLOR COUNTY �I � N GULF COUNTY u JOB NUMBER: JB0000238723 COUNTY LAFAYETT CLAY FRANKLIN COUNTY n"rr COUNTY COON sr LINTY couHrr ouu,r ALACHUA COUNTY JOB SITE: 583 COASTAL OAK LN, ATLANTIC BEA 'H FL 32233 Iv wE 5834 RICHARD ST U-1 JACKSONVILLE, FLORIDA 32296 PROJECT TOTALS PROPOSED AERIAL FOOTAGE 0' PROPOSED UG CATV/FIBER 304' TOTAL FOOTAGE 304' TOTAL PROPOSED BORES 4 TOTAL PROPOSED PEDS 3 TOTAL PROPOSED BORE PITS 1 g h PEDESTAL COUNTY r FIBER WA'T'ER - —WATER } t COUNTY TRANSFORMER POLE RISER POLE j� CULVERT VICINITY VIEW CITY: ATLANTIC BEACH SHEETNO: 1OF9 COUNTY: DUVAL SEWER —SEWER----- RIGHT OF WAY ---------- 04'X4'X4 BORE PIT BEGIN���- �� _ � �'�,� END C t,'i '21131 11 .��L G.aF �p MS..,��•m>x. +MM'S ^nxr.> "'''azse ZSk. `Y OatsYY ®vi.. h VICINITY MAP 583 COASTAL OAK LN, ATLANTIC BEACH, FL 32233 �I � N JOB NUMBER: JB0000238723 JOB SITE: 583 COASTAL OAK LN, ATLANTIC BEA 'H FL 32233 Iv wE 5834 RICHARD ST U-1 JACKSONVILLE, FLORIDA 32296 PROJECT TOTALS PROPOSED AERIAL FOOTAGE 0' PROPOSED UG CATV/FIBER 304' TOTAL FOOTAGE 304' TOTAL PROPOSED BORES 4 TOTAL PROPOSED PEDS 3 TOTAL PROPOSED BORE PITS 1 DIXIE PUTNAM COUNTY COUNTY FLAGLEF COUNTY LEVY COUNTY MARION COUNTY VOLUSIA COUNTY POLK OSCEOLA COUNTY COUNTY BREVARD COUNTY INDIAN RIVER COUNTY MANATEE HARDEE OKEECHOBEE COUNTY COUNTY OUNTY SAINT LUCIE 7_1HIGHLANDS COUNTY DESOTO COUNTY SARASOTA COUNTY COUNTY MARTIN COUNTY CHARLOTTE GLADES COUNTY COUNTY PALM HENDRY BEACH LEE COUNTY COUNTY COUNTY JAN 10 2020 as a •a.,! S C BORWARD COLLIERCOUNTY COUNTY MON COUNTY MIAMI-DADE� COUNTY TTY OF ATLANTIC BEACH LAKE CITRUS COUNTY COUNTY SEMINOI SUMTER COUNTY OUNTY SOWER HERNANDO PROPOSED TRENCH ----- COUNTY ORANGE PEDESTAL COUNTY PASCO FIBER WA'T'ER - —WATER PROPOSED BORE —DE—DU----CB---.,.. COUNTY POLK OSCEOLA COUNTY COUNTY BREVARD COUNTY INDIAN RIVER COUNTY MANATEE HARDEE OKEECHOBEE COUNTY COUNTY OUNTY SAINT LUCIE 7_1HIGHLANDS COUNTY DESOTO COUNTY SARASOTA COUNTY COUNTY MARTIN COUNTY CHARLOTTE GLADES COUNTY COUNTY PALM HENDRY BEACH LEE COUNTY COUNTY COUNTY JAN 10 2020 as a •a.,! S C BORWARD COLLIERCOUNTY COUNTY MON COUNTY MIAMI-DADE� COUNTY TTY OF ATLANTIC BEACH STREETLIGHT —SIL—S/L—SIL— - PROPOSED AERIAL —AP ---- © —A— X CONCRETE POLE JOINT USAGE POLE [V VAULT Y ANCHOR PROPOSED AERIAL & UG CAN/ FIBER FACILITIES IN DUVAL COUNTY, FLORIDA RIGHT-OF-WAY SOWER —E—E—— E PROPOSED TRENCH ----- X WOOD POLE PEDESTAL PERMIT FIBER WA'T'ER - —WATER PROPOSED BORE —DE—DU----CB---.,.. ® O TRANSFORMER POLE RISER POLE j� CULVERT VICINITY VIEW CITY: ATLANTIC BEACH SHEETNO: 1OF9 COUNTY: DUVAL SEWER —SEWER----- RIGHT OF WAY ---------- 04'X4'X4 BORE PIT SCALE: NOT TO SCALE STATE: FLORIDA DATE: 01-032019 DRAWN: FIBER CORE GROUP NOTES ALL PROPOSED CONSTRUCTION WILL BE PER THE CITY OF ATLANTIC BEACH SPECIFICATIONS AS WELL AS ALL NECESSARY SAFETY CODES. ALL PROPOSED CATV WILL BE WITHIN THE CITY OF ATLANTIC BEACH RIGHT-OF-WAY. ALL PROPOSED UNDERGROUND GMTV WILL BE BURIED A MINIMUM OF 36" DEEP EXCEPT ROAD BORES 60" DEEP AND DRIVEWAY BORES AT' 60" DEEP. ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL AS COUNTY APF 'ROVED CONDUIT. ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 17' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE= OF PAVEMENT. ALL PROPOSED BORES WILL BE IN /h (4'X4'X4') PIT AND WILL USE (2)2" HDPE CONDUIT AT 48" DEPTH USING A 5 1/4" DRILL HEAD. ALL PROPOSED AERIAL WILL BE .700" DIAMETER AND WILL BE LASHED TO .250" STEEL STRAND CABLE USING .125" STANDARD GALVANIZED LASHING WIRE. ALL PROPOSED AERIAL CAN CROSSING ROADWAYS WILL HAVE MINIMUM MID -SPAN HEIGHT OF 17'-0" ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE MINIMUM MID -SPAN HEI()HT OF 16-0" LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 41I'3 HRS PRIOR TO CONSTRUCTION. NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION. ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADING AND RE -SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION." WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR. CONSTRUCTION NOTES IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THE CASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT. THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT BE LIMITED TO -"SOFT DIG" -EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/ STATE INFRASTRURE AND THE EXISTING FACILITIES OF THE OTHER UTILITY COMPANIES IN w 'CITY OF ATLANTIC BEACH STREETLIGHT - - - POWER -E -E -E-- E C(0 K -D) RIGHT-OF-WAY FIBER 5934 RICHARD ST PERMIT WATER WATER 5 JACKSONVILLE, FLC;RIDA 32216 SEWER -SEWER----- ALL UTILITIES LOCATED BY VISUAL INSPECTION, TO BE VERIFIED BY LOCATES EOT REPRESENTS EDGE OF TRAVEL NOT TRUE EDGE OF PAVEMENT E/P REPRESENTS THE TRUE EDGE OF PAVEMENT EOD REPRESENTS THE EDGE OF DIRT HAND DIG TRENCHES 36" DEEP ACROSS DIRT ROAD RIGHT OF WAY PROPOSED AERIAL PROPOSEDTRENCH BURIED POWER ATB'f -- ATLT AT&T - GA.S ---,AAS- -GAS GAS STORM SEWER -SEWER SEWER-. WATER -WATER WATER - FENCE COAX - - - - © CONCRETE POLE QV VAULT PROPOSED AERIAL -AA A- X JOINT USAGE POLE Y ANCHOR PROPOSED TRENCH -- X WOOD POLE PEDESTA PROPOSED BORE -DB -DB -DB- ® TRANSFORMER POLE CULVEF - OR RISER POLE RIGHT OF WAY -------- O 4'X4'X4' BORE PIT PROPOSED AERIAL & UG CAN / FIBER FACILITIES IN DUVAL COUNTY, FLORIDA SHEET NO: 2 OF 9 SCALE: NOT TO SCALE DATE: 01-032019 CITY: ATLANTIC BEACH COUNTY: DUVAL STATE: FLORIDA DRAWN: FIBER CORE GROUP I M rr BEGIN PROJECT PROPOSED PED CAN FIBER FACILITIES c c STA: 00+00 GPS COORDINATES I Li N 30.343334 583 COASTAL OAK LN, ATLANTIC BEACH, FL 3223� 1 OF 1 BORE PIT (4'X4X4') WATER 6' BOC –COAX 12' BOC POWER 17'BOC /r-RUNLINE 12' BOC W -81.409663 In N w E: kcb.0e( 5934 RICHARD ST s JACKSONVILLE, FLOF 32216 24, I 16 v_ 6 4 1678 10' LANE BOC BOC ---rMWcOSTEL OAK LN 10 D/\A 10, LAN DNV DIA I o, LANE 2, CURB BOC Dl\N END PROJECT P — -- — -- PROPOSED PED C L CAN/ FIBER FACILITIES STA: 3+04 GPS COORDjqINATES N 30.343184 W -81.408862 CITY OF ATLANTIC BEACH RIGHT-OF-WAY PERMIT 1", 'Nkr," 71"fl --- -S/L-S/L-SIL - POWER -E -E -E - FIBER WATER -WATER SEWER --SEINER PROPOSEDAERIAL _SEWER 594 PROPOSEDAERIAL -A-A-A- PROPOSEDTRENCH PROPOSEDBORE -DB-DB-DB- RIGHT OF WAY © CONCRETE POLE [0 VAULT X JOINT USAGE POLE Y ANCHOR X WOOD POLE [] PEDESTA X TRANSFORMER POLE � CULVEF OR RISER POLE 0 4'X4'X4' BORE PIT ATER BOC 'TNq e0c c ST–, OC of\N to) 51 .'0 PROPOSED AERIAL & UG CATV / FIBER FACILITIES IN DUVAL COUNTY, FLOIDA PLAN VIFVV-1 CITY: ATLANTIC BEACH SHEET NO: 3 OF 9 DuvAL SCALE: NOT TO SCALE STATE: FLORIDA DATE: 0"3-2019 DRAWN: FIBER CORE GROUP 583 COASTAL OAK LN, ATLANTIC BEACH, FL 32233 CROSS SECTION DETAIL FOR COASTAL OAK LN 1 1 �- 1 64' 1 32' 32' 20' I 20' � 1 U 12' 12' 1 1 0" 12' 2�� 24 < 241, 36" 36" 1T 48" I 12' K 1 481 - U 6' 60" 1 OOU I U m m m m Uc° O °D °0 IW— O Luw Z S' O 0 U Z n0 D a0 W O CL O x CL N f �OMM/ O CONCRETE POLE (( 1} ca �`� 2�1'0 OF ATLANTIC BEACH D AERIAL —AA—A— STR EIT LIIGHTON S/L SJl —S/L— PROPOSE X JOINT USAGE POLE VAULT Y ANCHOR PROPOSED AERIAL FACILITIES IN & UG CRN / FIBER DUVAL COUNTY, FLOIDA W E } \y/uCITY RIGHT-OF-WAY POVe'ER—E—E—E— PROPOSED TRENCH X WOOD POLE Q PEDESTAL CROSS SECTION-A CIN: ATLANTIC BEACH 5934 RICHARD ST PERMIT FIBER PROPOSEDSORE—DB—DB--D6-- WATER —WATER --- -- - M ® TRANSFORMER RISE RISER POLE POLE =� CULVERT SHEET NO: 40F9 COUNTY: DUVAL SCALE: TO NOT TO SCALE STATE: FLORIDA Cs ,JACKSONVILLE, FLORIDA 32216 SEWER —SEWER RIGHT OF WAY—'-------- O 4' BORE PIT DATE: Ot-0 DRAWN: FIBER CORE GROUP i I I COASTAL OAK LN ATLANTIC BEACH, FL 32233 � 583 C o DIRECTIONAL ROAD BORE DETAIL FOR COASTAL OAK LN -64' U O ED O m _ (C CONCRETE POLE ❑V VAULT PROPOSED AERIAL & UG CATV / FIBER CITY OF ATLANTIC BEACH PROPOSED AERIAL — A -A -. STREETLIGHT —SIL—S/L—SIL— X JOINT USAGE POLE Y ANCHOR FACILITIES IN DUVAL COUNTY, FLOIDA w E U. V.J 1J ;(Q Io RIGHT-OF-WAY POWER E----E--E— PROPOSED TRENCH X WOOD POLE PEDESTAL ROAD BORE CITY: ATLANTIC BEACH PROPOSED BORE—QB—DB—DB--- ® TRANSFORMER POLE �j CULVERT FIBER SHEET NO: SOF9 COUNTY: DUVAL 5934 fICHARC,ST PERMIT WATER —WATER O RISER POLE SCALE: NOT TO SCALE STATE: FLORIDA JACKSONVILLE=, FLORIDA 32216 SEWER —SEWER RIGHT OF WAY —"—'— — 0 4'X4'X4'BOREPIT DATE: 01-03-2019 DRAWN: FIBER CORE GROUP 583 COASTAL OAK LN, ATLANTIC BEACH, FL 32233 DRIVE WAY BORE DETAIL ENTRY BORE \ RECEIVE VARIES BORE 0" DRIVEWAY 0I ---�I 21f 211 -----24" ---24" 60" DEPTH 36" 3611 -.48" --481 If (2) - 2" HDPE CONDUIT W/ 5 1/4" DRILL HEAD IN w E Caccc� 5934 RICHARD ST s JACKSONVILLE, FLORIDA ----- -- --- - © CONCRETE POLE []V VAULT PROPOSED AERIAL & UG CATV / FIBER CITY OF ATLANTIC BEACH STREETLIGHT --SIL—SIL—SIL— PROPOSEDAERtAL —A A—A— x JOINT USAGE POLE Y ANCHOR FACILITIES IN DUVAL COUNTY, FLOIDA RIGHT-OF-WAY POWER—E—E—E-- PROPOSED TRENCH — x WOOD POLE 0 PEDESTAL FIBER PROPOSED BORE—DB—DB—DB— ® TRANSFORMER POLE j� CULVERT DRIVEWAY BORE CIN: ATLANTIC BEACH PERMIT WATER —WATERSHEET NO: 6OF9 COUNTY: DUVAL - -- - - ® RISER POLE SCALE: NOT TO SCALE STATE: FLORIDA 32216 SEWER--SEWER RIGHT OFWAY ----------- O 4'X4'X4'BOREPIT DATE: 01-03-2019 DRAWN: FIBER CORE GROUP END ROAD WORK I A 5AHEAD x . SPEEDING FINES DOUBLED wHPREBEENTERS / DISTANCE BETWEEN SIGNS speed SPACING (FT) A B 40 mph or less 200 200 45 mph 350 350 50 mph or greater 500 500 ' 250' beyond the ROAD WORK AHEAD sign or midway between signs whichever is less B • TAPER LENGTH= 1/3L WORK AREA SEE TABLE 11 DEVICE SPACING -TAPER DEVICE SPACING -TANGENT SEE TABLE SEE TABLE SYMBOLS ® Work Area Device Spacing Channelizing Device (see Index 102-600) ��}•,, L}+ Work Zone Sign Speed Lane Identification - Direction of Traffic B • TAPER LENGTH= 1/3L WORK AREA SEE TABLE 11 DEVICE SPACING -TAPER DEVICE SPACING -TANGENT SEE TABLE SEE TABLE ROAD WORK AHEAD A a END ROAD WORK GENERAL NOTES DURATION NOTES 1. Signs and channelizing devices may be omitted if all of the 1. IINhen four or more work vechicles enter the through traffic lanes in a one hour following conditions are met ,Oeriod or less (exsiuding cstablishing and terminating the work area), the advanced a. Work operations are 60 minutes or less. FLAGGER sign shaft be substituted forthe WORKERS sign. for location of flaggers b. Vehicles in the work area have high-intensity, and FLA GGER signs, see index no. 102-603. rotating, flashing, oscillating, or strobe lights 2. iHOULDER work sign may be used as an alternate to the WORKER symbol sign only operating. on the side whers the shoulder work is being performed. 3. il'Vhen a side road intersects the highway within the TTC zoos, additional TTC tievices shall be placed in accordance with other application TCZ indexes. 4. 1"or general TCZ requirements and additional information, refer to Index 102-600. TABLE 11 Taper Length - Shoulder Table I speed (mph) 8' Shldr. Device Spacing 12' Shldr Notes Max. Distance Between Devices (ft.) Speed Cones or Type / or Type It (mph} 30' 40' 50' 60' Barricades or Vertical 40' 72' 90' 107' Tubular Markers Panels or Drums 150' Taper I Tangent Taper Tangent 25 25 50 25 50 30 to 45 25 50 30 50 50 to 70 25 1 50 50 100 ROAD WORK AHEAD A a END ROAD WORK GENERAL NOTES DURATION NOTES 1. Signs and channelizing devices may be omitted if all of the 1. IINhen four or more work vechicles enter the through traffic lanes in a one hour following conditions are met ,Oeriod or less (exsiuding cstablishing and terminating the work area), the advanced a. Work operations are 60 minutes or less. FLAGGER sign shaft be substituted forthe WORKERS sign. for location of flaggers b. Vehicles in the work area have high-intensity, and FLA GGER signs, see index no. 102-603. rotating, flashing, oscillating, or strobe lights 2. iHOULDER work sign may be used as an alternate to the WORKER symbol sign only operating. on the side whers the shoulder work is being performed. 3. il'Vhen a side road intersects the highway within the TTC zoos, additional TTC tievices shall be placed in accordance with other application TCZ indexes. 4. 1"or general TCZ requirements and additional information, refer to Index 102-600. TABLE 11 Taper Length - Shoulder speed (mph) 8' Shldr. 113L (ft.) 10' Shldr 12' Shldr Notes 25' 28' 35' 42' L 60S2 30' 40' 50' 60' 35' 55' 68' 82' 40' 72' 90' 107' 45' 120' 150' 180' L= wS 50' 133' 16T 200' 55' 147' 183' 220' 60' 160' 200' 240' 65' 173' 217' 260' 70' 187' 233' 280' B' minimum shoulder width. 1131= length of shoulder taper in feet w = width of total shoulder in feet (combined paved and unpaved width) s = posted speed limit (mph) CONDITIONS WHERE ANY VEHICLE, EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER THAN 15' BUT NOT CLOSER THAN 2' TO THE EDGE OF TRAVEL WAY. DESCRIPTION: - ' LAST FY 2019-20 INDEXREVISIOSHEET 01110117 FEMI STANDARD PLANS TWO-LANE, TWO-WAY, WORK ON SHOULDER 902-602 7 OF 9 BUFFER SPACE B Co aNE, TWO-WAY SYMBOLS ® Wak Area D Wxkzone Sign 45 Ragger 50 or Greater Trefic Cartrol 075cer C=:> Lane Identification i Drection of Trafflc BUFFER SPACE speed Dist. (mph) (ft) 25 155 30 200 35 250 40 305 45 360 50 425 55 495 60 570 65 645 DISTANCE BETWEEN SIGNS Speed (mph) 40 or/ess spa-ing (R.) 45 a2002OO !20-0 50 or Greater D BUFFER SPACE C B A 1 41 �V 4 10 A — B C BUFFER SPACE OA<1 BE ARK PREPAftfO aHEAo TO &TOP<* MULTILANE GENERAL NOTES 1. This index does not apply to limited access facilities. 2. When a side road intersects the highway within the TTC zone, additional ttc devices shall be placed in accordance with applicable TCZ Indexes. 3. Traffic volume or complexity of the roadway may dictate additional devices, signs, flagmen andlor a traffic control officer. 4. The buffer space may be omitted if there are no sight obstructions to vehicles approaching the Flagger/Officer for distance equal to the bufferspace. 5. A Flagger may be substituted for a traffic control officer and the BE PREPARED TO STOP sign may be omitted, when the following conditions are met: a. Speed limit is 45 mph or less b. No sight obstructions to vehicles approaching the Flagger/Officer for a distance equal to the buffer space. c. vehicles in the work area have high-intenseity, mating, flashing, oscillating, orstrobe lights operating. 6. On undivided highways the median sign as shown are to be omitted. 7. For general TCZ requirements and addifional information refer to Index 102-600. CONDITIONS PLANNED CLOSURE NOT EXCEEDING 5 MINUTES LAST FY 2099-20 INDEX SHEET REVISION STANDARD PLANS TEMPORARY ROAD CLOSURE 5 MINUTES OR LESS f 1 "' 902-625 & OF 9 THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION 2()1 9-2020 102-600 INDEX AND APPLY TO 583 CC )ASTAL OAK LN, ATLANTIC BEACH, FL 32233 • STANDAFV PLANS INDEX NO 102-602 (TKIO-LANE, TWO-WAY, WORK ON SHOULDER) • STANDARD PLANS INDEX NO 102-625 (TEMPORARY ROAD CLOSURE 5 MINUTES OR LESS) N C W E 111 CONCRETE POLE VAULT PROPOSED AERIAL & UG CATV / FIBER CITY OF ATLANTIC BEACH STREETLIGHT -SIL-SIL-SIL- PROPOSED AERIAL -A -A -A- X JOINT USAGE POLE Y ANCHOR FACILITIES IN DUVAL COUNTY, FLOIDA 'O'vl'ER-E-E-E-- PROPOSED --------- WOOD POLE TRAFFIC CONTROLRULES-01 a RIGHT-OF-WAY X ❑ PEDESTAL CITY: ATLANTIC BEACH ?'f `= .. 59:4 RICHARD ST �.-iQER - PROPOSED BORE -DB -DB -DB- Z TRANSFORMER POLE 17:1 CULVERT PERMIT -. SHEET NO: 9 WATER OF9 COUNTY: DUVAL -WATER - - --- - �R RISER POLE J'ACKSONVILLE,FLORIDA.3�G1�1 SCALE: NOT TO SCALE STATE: FLORIDA >EWEp ..,___._ r .u____-_...._. RIGHT OF WAY ---"--- O 4'X4'X4'BORE PIT DATE: 0113-2019 DRAWN: FIBER CORE GROUP