183 Seminole Rd ACRS20-0021 MECHANICAL RESIDENTIAL HVAC PERMIT NUMBER r . *At PERMIT ACRS20-0021 Ammo!o ISSUED: 1/22/2020 ,��, CITY OF ATLANTIC BEACH EXPIRES: 7/20/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 183 SEMINOLE RD MECHANICAL RESIDENTIAL HVAC- 1 A/C, 1 AHU, 2 TON $8300.00 HVAC TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 170606 0000 SALTAIR SEC 01 COMPANY: ADDRESS: CITY: STATE: ZIP: HAMMOND AIR 3412 GALILEE RD JACKSONVILLE FL 32207 CONDITIONING INC OWNER: ADDRESS: CITY: STATE: ZIP: BERMAN HANNAH S ET AL 183 SEMINOLE RD ATLANTIC BEACH FL 32233-4140 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT AC AND REFRIGERATION 455-0000-322-1000 2 $16.00 AIR DUCT SYSTEM 455-0000-322-1000 80 $20.00 FURNACES AND HEATING 455-0000-322-1000 2400 $24.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.38 Issued Date: 1/22/2020 1 of 2 (p...0 MECHANICAL RESIDENTIAL HVAC PERMIT NUMBER ( 0% ACRS20-0021 ,. 0 PERMIT ulyr ISSUED: 1/22/2020 r. a r: , CITY OF ATLANTIC BEACH EXPIRES: 7/20/2020 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.25 WORK WITHOUT PERMIT 455-0000-322-1000 0 $110.00 TOTAL: $230.63 Issued Date: 1/22/2020 2 of 2 Mechanical Permit Application '=ALL INFORMATION ( '''' ' ' HIGHLIGHTED IN ,. City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-3826 Email: Building-Dept@coab.us PERMIT#: l {J- 002\ em JOB ADDRESS: r6 C L.'s`.r,. f".1‘4\Oa -N3t..\,1 PROJECT VALUE$ r;CCJ, °C' r NEW AIR CONDITIONING& HEATING SYSTEM INSTALLATION AR/#(REQU/R D) IteC j;(o 0 Air andling Equipment Only 0 Condenser OnlyAir Handling Unit& Condenser Air Con itioning: Unit Quantity I Tons per Unit - Heat: Unit Quantity l BTUs per Unit 2.`{,tiacrc Seer Rating(REQUIRED) ; '" , , Duct Sy�tems: Total CFM L)() (—]REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED) ❑Air Handling Equipment Only 0 Condenser Only CI Air Handling Unit& Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: 1Unit Quantity BTU's Per Unit Seer Rating(REQUIRED) Duct Syterns: Total CFM 1 ❑FIRE PRVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Comme cial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) EFIRE PL4CES fl MISCELLANEOUS: Prefabr Gated Fireplace (Qty) Automobile Lifts Gas Piping Outlets Boilers BTUs Elevators/Escalators GALL 0ER GAS PIPING Heat Exchanger Quant' of Outlets Pumps # Vente Wall Furnaces Refrigerator Condenser BTUs #Waterj Heaters Solar Collection Systems Tanks (gallons) Wells ■OTHER: Permit becdmes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation constructionsor the performance of construction. Owner Nartte: _�"1 i��N�� rt�.oN Phone Number: /0`1,---2.4 i0.O'S"w: Mechanical Company: LI A(hYr ,ot.Jb At r C A"rc...a: Office Phone: reT ,S'"(,q` Fax 3oj r`(DOE>t Co.Address: 3111. �7' w\• t,e. ,01%.4 City: K 1\ State Ti..-- Zip:31.1c1 License Holder: 14PON'telVsr.C. State Certification/Registration# L' U1-1c ‘,EU Notarized$Ignature of License Holder � %'1? The foregoing instrument was acknowledged before me this ' ) day of Jurrvct.,c ,20 ./,' , in the State of Florida, County of 1 U.1 i - [ � Signature of Notary Public'----4-64,.---..-,6",. L.-„ 1. } ♦►t`Y r 1 NANCY JANE DEMPSEY 44A:14 'r'�� ., Commission i GG 301072 ['-rPersonally Known OR[ } Produced Identification 0. E keo Fetxusry 12,2023 Type of Identification: -- '''r,„,‘,"" 11.0d Nub4Q Kola YS+nkos Updated 10/9/18 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project fume: 183 Seminole Remodel Builder Name: Street: 1 183 Seminole Rd Permit Office: Duval City,Stas,Zip: Atlantic Beach,FL,32233 Permit Number: Owner. Jurisdiction, Design Location: FL,Jacksonville County Duval(Florida Climate Zone 2) 1. New construction or existing Existing(Projecte 9. Wall Types(1161.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 820.00 ft' b.Frame-Wood,Exterior R=19.0 341.33 ft' 3, Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 3 d.N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types (1227.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 1227.00 ft' 6. Conditigned floor area above grade(ft') 1227 b.N/A R= ft' Conditidned floor area below grade(ft') 0 c.N/A R= ft2 11.Ducts R ft' 7. Windows(148.5 sqft.) Description Area a.Sup.Attic,Rot:Attic,AH:Main 6 110 a. U-Fa or: Dbl,U=0.35 84.50 ft' SHG : SHGC=0.25 b. U-Factor: Dbl,U=0.32 64.00 ft' 12.Cooling systems kBtu/hr Efficiency SHG SHGC=0.19 a.Central Unit 24.0 SEER:15.30 c. U-Fa or. N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a.Electric Heat Pump 24.0 HSPF:8,70 I SHGC. Area Weighted Average Overhang Depth: 1.167 ft. Area Weighted Average SHGC 0.224 14.Hot water systems 8. Floor Types (1227.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.940 a.Slab-On-Grade Edge Insulation R=0.0 1227.00 ft' b Conservation features b.N/A R= ft' None c.N/A R= ft' 15.Credits CF,Pstat Total Proposed Modified Loads: 38.52 PASS Glass/Floor Area: 0.121 Total Baseline Loads: 39.80 I hereby certify that the plans and specifications covered by Review of the plans and ��,0e E�TATFO,' this calculation are in compliance with the Florida Energy specifications covered by this = .P .'S.,,0 calculation indicates compliance,` /", -• :° �� f` with the Florida Energy Code. • "'.•, w.,`,•4.- 4 PREPARED BY: M ,, 2019.1 0.16 Before construction is completed w i nee$ ;e: DATE: ' this buildingwill be inspected for cs O 18:55:40 04 00 p Le e ee ewe reiore'"''eoeooe compliance with Section 553.908 k .‘,,,„.546,4, I hereby certify that this building, as designed, is in compliance Florida Statutes. ,tele,; ' .m with the Florida Energy Code. .C'°L)W E19. +o OWNER/AGENT: BUILDING OFFICIAL: -_-- DATE: .. _ DATE: . - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACI-150(R402.4.1.2). 10/16!2019 6.42 PM EnergyGaugeS USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 OFFICE COPY Revision Request/Correction to Comments **ALL HIGHLIGHTED IN ION ' ` ���.: IN 't� City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 f e R`J Z0 - 0 Z st Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: ❑ Revision to Issued Permit OR Corrections to Comments Date:--- 13--(;,,(y Project Address: ) 23 .e rr‘•nc,`n ace i--14‘,,,\,, ,_,,-h ) --? Contractor/Contact Name: 4-k c„ „,,,A 4;(-- Contact Contact Phone: 90y- 3'' –(„ C( s ' Email: -Hp..0,,,,'crO(n; t , ---4 ,..t.1-, 0-,,,--,, l -c',_k-+ Description of Proposed Revision/Corrections: 0 C.A CA— 1 I \-Ai M C10Cif s/ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Will proposed revision/corrections add additional square footage to original submittal? ❑No ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? ❑No C*Yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) [ Approved [ i Denied 1 Not Applicable to Department Permit Fee D - $ II,e, Revision/Plan Review Comments (_e5 ft jaC1– -to pT C/c” Tolo copy 124 VI Soh $ pay �-e€- Department Review Required: Buildin -171,)-- Planning&Zoning eviewed By Tree Administrator Public Works REVISION Public Utilities 2 f 41,2-0 Public Safety BP# ,iC S aO " Col e Fire Services DATE a- / l 2 / ao Updated 10/17/18 SIGNED m REVISION BP# / /2$2o-oo,/ OFFICE COPY DATE 9- / / / 0 SIGNED •-Orr • 144 IT' t?-cr xt_•tt• C-4 114* 6'.73•4•mow_ III������JJJ .. M i • b ,O 4 • tiv '• ‘ crop 0 k t i01 1 ._ ri, 4. . _LI: 4 Li _47), y 1 t- . It, E J ERoon I L 9 !�!�� 0 u x rriL 4 1 0 a \ Vit" ..—irami. toa ' ' rte. ,.Ill 441•1141 TA . i. 4 ice )• t n nill _�-- 1W �� `—__ s � / jr ,-•4112'• i Kral A iw r l' 111 (1) ILI a 8110.143224A I I eipprw. 8 , __ _ ,, _ ,. . . , . _____., . i, O 0 i REF. 1" , Imo.(. I i •1 r....a. 11 ,. t[.t■ n M ' I ';' ' DA of s i; r: .4 { 'I '4 }R�.tvr1a 18 '3 Sem; nole:RA ATLA?.. TrC. 56-14c1-+, PLUSZ=DA 333 ACS Sao- ool r�y,,,a ,. Revision Request/Correction to Comments "ALL INFORMATION J. j HIGHLIGHTED IN boor City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233-` Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: 0 Revision to Issued Permit OR ❑ Corrections to Comments Date: )—3 ) — ( '"I/ Project Address:1 33 J c i'Y i l I --.))4,..?_, CD J Contractor/Contact Name: t'J1 N. I )I6 A).7 /9 I (P., Contact Phone: qby 39-8 (Y`)SLV Email: Description of Proposed Revision/Corrections: \ e-[N( C1 0--0 ae--S I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) JAN 3 1 2020 • Will proposed revision/corrections add additional square footage to original submittal? ❑No ❑ Yes(additional s.f. to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? ❑No ❑*Yes(additional increase in building value:$ )(Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) I Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments Department Review Required: ui gllag— Planning& Zoning Reviewed By Tree Administrator Public Works Public Utilities Public Safety Date Fire Services Updated 10/17/18 .,:l ,r,, Revision Request/Correction to Comments **ALL INFORMATION 4' - ; HIGHLIGHTED IN ;S44'Lw City of Atlantic Beach Building Department GRAY IS REQUIRED. \ 800 Seminole Rd, Atlantic Beach, FL 32233 � =' Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: �� C" �O OOZ 0 Revision to Issued Permit OR E Corrections to Comments Date: )—3 ) — W16/ Project Address:1 3,> S I IV(-n4,?., Eb JJ Contractor/Contact Name: Hi:41N 1 o D A l a Contact Phone: qOu 39',F; (OL)Sj1" Email: Description of Proposed Revision/Corrections: C©8..e_S I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) JAN 3 1 2020 • Will proposed revision/corrections add additional square footage to original submittal? ❑No ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? ❑No ❑*Yes (additional increase in building value:$ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) _ Approved LDenied ❑ Not Applicable to Department Permit Fee D(175-6. 0 Cl.....) Revision/Plan Review Comments leeiVity /2t`!, s ?ra„n 1e7S# /`t.V.QV JJ* / .tvar S'binvett/tti r.. f3osC.v Su: /dors. C/JLt/:o) Department Review Required: itumarthip- : /illy Planning&Zoning Reviewed By Tree Administrator Public Works u Public Utilities a " / "e:10 Public Safety Date Fire Services )04 0 -zi? ‘ ) ac-No LVW -} 2 00 02 SAO Q-Docci ) zoo - 1, 1 r;____ i r\J\r. kCITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING REVIEW COMMENTS Date: 2/4/2020 Permit#: ACRS20-0021 Site Address: 183 SEMINOLE RD Review Status: Denied RE#: 170606 0000 Applicant: HAMMOND AIR CONDITIONING INC Property Owner: BERMAN HANNAH SET AL Email: NANCY.HAMMONDAIR@GMAIL.COM Email: MBERMAN@MEDIASHARECONSULTING.COM Phone: 9046266867 Phone: 9048384962 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. I am sending the review comments that were sent to Bosco Builders after the they submitted hvac documents resulting from the Stop Work Order at 183 Seminole Rd. The request s from that review have not been met by your recent submittal. 2. The duct floor plan layout needs to be on a 8.5X14 inch page as the one submitted was to small to read. 3. The information below is from the original review request form that was sent to Bosco Builders. Correction Comments: 1. Todd, at the time when the permit application was reviewed I was under the impression that replacing the HVAC system would just be a change out. That is not the case now. Energy calculation were submitted but they did not contain a DUCT SYSTEM SUMMARY REPORT and a duct layout floor plan which I customarily get with a new single family home. Because of the complete gutting of this house we should have treated this home that way and even terminated the power and got a temporary power pole. I need from Mr. Hammond 2 copies of the Duct Summary and the 2 copies of the duct layout. The duct summary report is usually generated with the energy calc software. 2. I also need to know why the AHRI number submitted on his hvac permit does not match the number that is recorded on the Manual S. They are supposed to. Building ENERGY CODES Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904)247-5844 Email:mjones@coab.us Building Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 183 Seminole Remodel Builder Name: Street: 183 Seminole Rd Permit Office: Duval City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: Design Location: FL,Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing Existing(Projecte 9. Wall Types(1161.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 820.00 ft2 b.Frame-Wood,Exterior R=19.0 341.33 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1227.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 1227.00 ft2 6. Conditioned floor area above grade(ft2) 1227 b.N/A R= ft2 ft2 Conditioned floor area below grade(ft2) 0 c. R= 11.Ducts R ft2 7. Windows(148.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 275 a. U-Factor: Dbl,U=0.35 84.50 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl,U=0.32 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.19 a.Central Unit 24.0 SEER:15.50 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.167 ft. Area Weighted Average SHGC: 0.224 14.Hot water systems 8. Floor Types (1227.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.940 a.Slab-On-Grade Edge Insulation R=0.0 1227.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits CF,Pstat Total Proposed Modified Loads: 38.39 Glass/Floor Area: 0.121 PASS Total Baseline _oads: 39.80 I hereby certify that the plans and specifications covered by Review of the plans and .•••''GTHE ST,�T••: this calculation are in compliance with the Florida Energy specifications covered by this ?`v�, h _ ,FOS Code. calculation indicates compliancelg..,, with the Florida EnergyCode. 2020.01.30 �ti ,,,�•,,:• �=:� ..,,;;;:�,,��s PREPARED BY: Before construction is completed 1,:L4' _ , w. i 19:58.26 this buildingwill be inspected for j DATE: Wilt,',J4„,,,...rim. P ',.�,' °' °" -05'00' compliance with Section 553.908 a : ;, I hereby certify that this building, as designed, is in compliance , Florida Statutes. �.,,•.�� "y �• `. with the Florida Energy Code. ''•COD wE' ..•• ... OWNER/AGENT: 1 BUILDING OFFICIAL: DATE: . DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 183 Seminole Remodel Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1227 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 270 Street: 183 Seminole Rd Permit Office: Duval Cross Ventilation: County: Duval Jurisdiction: Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233 New/Existing: Existing(Projected) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 1227 9816 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1227 9816 Yes 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 145 ft 0 1227 ft2 ___ 0.3 0.3 0.4 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch �/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1265 ft2 152 ft2 Medium N 0.96 No 0.9 No 20 14 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1227 ft2 N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 0 Blown 1227 ft2 0.11 Wood 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it Ornt To Wall Type Space R.Valye Ft In Ft In Area R-Value Fraction Absor Grnrle% 1 N=>W Exterior Concrete Block-Int Insul Main 5 23 6 8 188.0 ft2 0 0.75 0 2 W=>S Exterior Concrete Block-Int Insul Main 5 39 6 8 316.0 ft2 0 0.75 0 3 E=>N Exterior Concrete Block-Int Insul Main 5 39 6 8 316.0 ft2 0 0.75 0 4 S=>E Exterior Frame-Wood Main 19 23 6 8 188.0 ft2 0.23 0.75 0 5 W=>S Exterior Frame-Wood Main 19 9 7 8 76.7 ft2 0.23 0.75 0 6 E=>N Exterior Frame-Wood Main 19 9 7 8 76.7 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated Main None .38 3 6 8 20 ft2 2 W=>S Insulated Main None .38 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.35 0.25 N 25.5 ft2 1 ft 2 in 2 ft 0 in None None 2 W=>S 2 Vinyl Low-E Double Yes 0.35 0.25 N 18.0 ft2 1 ft 2 in 2 ft 0 in None None 3 W=>S 2 Vinyl Low-E Double Yes 0.35 0.25 N 6.0 ft2 1 ft 2 in 2 ft 0 in None None 4 E=>N 3 Vinyl Low-E Double Yes 0.35 0.25 N 26.0 ft2 1 ft 2 in 2 ft 0 in None None 5 E=>N 3 Vinyl Low-E Double Yes 0.35 0.25 N 9.0 ft2 1 ft 2 in 2 ft 0 in None None 6 S=>E 4 Vinyl Low-E Double Yes 0.32 0.19 N 6.0 ft2 1 ft 2 in 2 ft 0 in None None 7 S=>E 4 Vinyl Low-E Double Yes 0.32 0.19 N 40.0 ft2 1 ft 2 in 2 ft 0 in None None 8 E=>N 6 Vinyl Low-E Double Yes 0.32 0.19 N 18.0 ft2 1 ft 2 in 2 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1145.2 62.87 118.24 .1339 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 24 kBtu/hr 800 cfm 0.75 1 sys#1 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.94 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS --Supply---- Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ft2 Attic 240 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar A r Ma X Jun X Jul X Au X Se Oct Nov Dec Heatin [X Jan ;X Feb 'X1 Mar E Ar f Ma4 Jun 4 Jul 4 Aug4 Sef Oct 'X Nov [X Dec Venting [ Jan Feb X Mar [X Apr [ May [ Jun [ Jul [ Aug [ Sep [X Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(\ND) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Main 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Existing(Projected) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq. ft.) 6. 1227 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.337 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.224 14. Heating system: Capacity 24.0 c)Area 7c. 148.5 a)Split system heat pump HSPF 9.0 b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c) Concrete, raised(R-value) 9c. a) Electric resistance EF 0.94 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. 19.0 e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 1061. 2. Masonry(Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a)Ceiling fans Yes a) Under attic 11a. 0.0 b)Cross ventilation No b)Single assembly 11b. c)Whole house fan No c)Knee walls/skylight walls 11c. d)Multizone cooling credit d)Radiant barrier installed 11d. No e)Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 183 Seminole Rd City/FL Zip: Atlantic Beach, FL 32233 1/30/2020 7:52:22 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 183 Seminole Rd Permit Number: Atlantic Beach,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. ✓ SECTION R401 GENERAL DR401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law(Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. ▪ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal enveldlbe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. ElR402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. ▪ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ▪ R402.4.3 Fenestration air leakagndows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) DR402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes:hot.gn cond'tioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory) All ducts, air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers.shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7) Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Seateo air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manuft air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. nR403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13°C)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight, moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe ❑ shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). O 8403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. O R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. • R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFMNVATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. O R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. O R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ▪ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. D R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. O R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 ElR403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. ❑ R403.11 Portable spas(Mandatory�,e energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS El R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Job Information Builder: Community: Lot: NA Address: 183 Seminole Rd City: Atlantic Beach State: FL Zip: 32233 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2. O PERFORMANCE or ER:METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value. as shown on Form R405-2017(Performance)or R406-2017(ERI),section labeled as infiltration,sub-section ACH50. A Cl-i(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7.000 x 60 _ 9816 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans PASS •Code software calculated When ACH(50)is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: issuing Authority: 1/30/2020 7:52:41 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 183 Seminole Remodel Builder Name: Street: 183 Seminole Rd Permit Office: Duval City,State,Zip: Atlantic Beach,FL,32233 Permit Number: v Owner: Jurisdiction: Design Location: FL,Jacksonville c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors j The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) ; of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations I Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities ' cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls :boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. • Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1/30/2020 7:52 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 Building Input Summary Report PROJECT Title: 183 Seminole Remodel Address type: S Building Type: User Bedrooms: 3 Lot#: Owner: Conditioned Area: 1227 Block/SubDivision: Total Stories: 1 PlatBook: Builder Name: Worst Case: No Street: 183 Seminole Rd Permit Office: Duval Rotate Angle: 270 County: Duval Jurisdiction: Cross Ventilation: City,State,Zip: Atlantic Beach, Family Type: Single-family Whole House Fan: FL,32233 New/Existing: Existing(Projected) Terrain: Suburban Year Construct: 2018 Shielding: Suburban Comment: CLIMATE V /Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INTL_A 32 93 70 75 1281 49 Medium UTILITY V Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh EnergyGauge Default 0.00 0.12 _Natural Gas Therm EnergyGauge Default 0.00 0.68 Fuel Oil Gallon EnergyGauge Default 0.00 1.10 Propane Gallon EnergyGauge Default 0.00 1.40 SURROUNDINGS Shade Trees Adjacent Buildings Ornt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft BLOCKS • VNumber Name Area Volume 1 Block1 1227 9816 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _1 Main 1227 9816 Yes 4 3 Yes Yes Yes 1/30/2020 7:53:10 PM EnergyGauge®/USRCZB v6.1 Page 1 Building Input Summary Report FLOORS (Total Exposed Area = 1227 sq.ft.) V# Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _1 Slab-On-Grade Edge Ins Main 145 0 1227 ft 0.587 --- 0.3 0.3 0.4 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1265 ft2 152 ft2 Medium N 0.96 No 0.9 No 20 14 ATTIC V# Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1227 ft2 N N CEILING (Total Exposed Area = 1227 sq.ft.) V# Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type 1 Under Attic(Unvented) Main 0.0 Blown 1227.0ft2 0.062 0.11 Wood WALLS (Total Exposed Area = 1161 sq.ft.) Note:First wall orientation below is as entered.Actual orientation is modified by the rotate angle(270 degrees)as shown in the"Project"section on page 1. Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below V# Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _1 N=>W Exterior Conc.Blk-Int Ins Main 5.0 23.0 6 8.0 0 188.0 0.132 0 0.75 0% _2 W=>S Exterior Conc.Blk-Int Ins Main 5.0 39.0 6 8.0 0 316.0 0.132 0 0.75 0% _3 E=>N Exterior Conc.Blk-Int Ins Main 5.0 39.0 6 8.0 0 316.0 0.132 0 0.75 0% _4 S=>E Exterior Frame-Wood Main 19.0 23.0 6 8.0 0 188.0 0.071 0.23 0.75 0% _5 W=>S Exterior Frame-Wood Main 19.0 9.0 7 8.0 0 76.7 0.071 0.23 0.75 0% _6 E=>N Exterior Frame-Wood Main 19.0 9.0 7 8.0 0 76.7 0.071 0.23 0.75 0% DOORS (Total Exposed Area = 40 sq.ft.) Width Height ✓# Omt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area _1 N=>W Exterior Insulated Main None 0.38 3.00 0 6.00 8 20.0ft2 2 W=>S Exterior Insulated Main None 0.38 3.00 0 6.00 8 20.0ft2 WINDOWS (Total Exposed Area = 149 sq.ft.) Wall Overhang ✓# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening _1 N=>W 1 Vinyl Low-E Double Yes 0.35 0.25 N N 25.5ft2 1.0 ft 2 in 2.0 ft 0 in None None _2 W=>S 2 Vinyl Low-E Double Yes 0.35 0.25 N N 18.0ft2 1.0 ft 2 in 2.0 ft 0 in None None _3 W=>S 2 Vinyl Low-E Double Yes 0.35 0.25 N N 6.0ft2 1.0 ft 2 in 2.0 ft 0 in None None _4 E=>N 3 Vinyl Low-E Double Yes 0.35 0.25 N N 26.0ft2 1.0 ft 2 in 2.0 ft 0 in None None _5 E=>N 3 Vinyl Low-E Double Yes 0.35 0.25 N N 9.0ft2 1.0 ft 2 in 2.0 ft 0 in None None _6 S=>E 4 Vinyl Low-E Double Yes 0.32 0.19 N N 6.0ft2 1.0 ft 2 in 2.0 ft 0 in None None _7 S=>E 4 Vinyl Low-E Double Yes 0.32 0.19 N N 40.0ft2 1.0 ft 2 in 2.0 ft 0 in None None 8 E=>N 6 Vinyl Low-E Double Yes 0.32 0.19 N N 18.0ft2 1.0 ft 2 in 2.0 ft 0 in None None 1/30/2020 7:53:10 PM EnergyGauge®/USRCZB v6.1 Page 2 Building Input Summary Report INFILTRATION V# Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s) _1 Wholehouse Proposed ACH(50) 0.00036 1145 62.87 118.24 0.1339 7.0 All _ MASS Ma:Type# ype Area Thickness Furniture Fraction Space 1 Default(8 lbs/sq.ft.) 0 ft2 0 ft 0.30 Main HEATING SYSTEM V# System Type Subtype AHRI# Efficiency Capacity ----Geothermal HeatPump---- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split 201663456 HSPF:9.00 24.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM V# System Type Subtype AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split 201663456 SEER:15.5 24.0 800 0.75 sys#1 1 HOT WATER SYSTEM V# System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Main 0.94(0.93) 50.00 gal 60 gal 120 deg Standard =>R-3 100 — Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS Duct Supply Return Air CFM 25 CFM 25 HVAC# V # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 275 ft2 Attic 6.0 240 ft2 Default Leakage Main (Default)(Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: N Cooling []Jan []Feb []Mar []Apr []May [X]Jun [X]Jul [X]Aug [X]Sep []Oct []Nov []Dec Heating [X]Jan [X]Feb [X]Mar []Apr []May []Jun []Jul []Aug []Sep []Oct [X]Nov [X]Dec Venting []Jan []Feb [X]Mar [X]Apr []May []Jun []Jul []Aug []Sep [X]Oct [X]Nov []Dec V/ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 1/30/2020 7:53:10 PM EnergyGauge®/USRCZB v6.1 Page 3 Building Input Summary Report TEMPERATURES(Continued) Hea: AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 65 65 65 65 .33 65 68 68 68 68 68 PM 68 68 68 68 b8 68 68 68 68 68 68 68 HARD WIRED LIGHTING ID Type y Screen Location Total# Quantity# Comp Fl All Other Fl Bulb Type Schedule Watts per bulb 1 Hard-Wired Default Exterior 20 2 HERS2011 60 MISC ELECTRICAL LOADS VD Type Screen Location Item Quantity Catagory Operating Schedule Off Standby _1 Misc Elec Load Simple Default Main 1 1 HERS2011 1 APPLIANCES & LIGHTING SCHEDULES Appliance Schedule: HERS2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Occupancy peak: 400 Btu AM 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.980 0.460 0.270 0.270 0.270 ll %Released: 100 % PM 0.270 0.270 0.270 0.270 0.330 0.610 1.000 1.000 0.930 0.930 0.930 0.930 refrig peak: 0 W AM 0.824 0.804 0.784 0.764 0.744 0.734 0.744 0.754 0.764 0.794 0.814 0.854 %Released: 100 % PM 0.854 0.864 0.884 0.904 0.925 0.945 0.925 0.915 0.904 0.894 0.874 0.854 cWash peak: 0 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 %Released: 30 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 i E-cDry peak' 0 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 % Released: 15 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 dWash peak: 0 W AM 0.139 0.050 0.028 0.024 0.029 0.090 0.169 0.303 0.541 0.594 0.502 0.443 %Released: 60 % PM 0.376 0.396 0.334 0.323 0.344 0.448 0.791 1.000 0.800 0.597 0.383 0.281 E-rOven peak: 0 W AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.400 %Released: 80 % PM 0.457 0.343 0.286 0.400 0.571 1.000 0.857 0.429 0.286 0.229 0.171 0.114 TVs peak: 226 W AM 0.100 0.050 0.050 0.050 0.100 0.200 0.400 0.450 0.400 0.200 0.100 0.100 %Released: 100 % PM 0.050 0.050 0.150 0.450 0.850 1.000 0.950 0.800 0.500 0.250 0.150 0.100 cFan peak: 0 W AM 0.600 0.600 0.600 0.600 0.600 0.600 0.600 0.250 0.250 0.250 0.250 0.250 %Released: 100 % PM 0.250 0.250 0.250 0.250 0.250 0.250 0.550 0.600 0.600 0.600 0.600 0.600 lgts-in peak: 0 W AM 0.160 0.150 0.160 0.180 0.230 0.450 0.420 0.260 0.190 0.160 0.120 0.110 %Released: 100 % PM 0.160 0.170 0.250 0.270 0.340 0.550 0.600 0.880 1.000 0.880 0.510 0.280 lgts-out peak: 43 W AM 1.000 1.000 1.000 1.000 1.000 0.750 0.750 0.000 0.000 0.000 0.000 0.000 %Released: 0 % PM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.500 0.750 0.750 0.750 1.000 lgts-gar peak: 0 W AM 0.000 0.000 0.000 0.000 0.000 0.500 0.750 1.000 0.750 0.500 0.000 0.000 %Released: 0 % PM 0.000 0.000 0.500 0.500 0.750 1.000 0.750 0.500 0.000 0.000 0.000 0.000 MEL peak: 0 W AM 0.500 0.500 0.500 0.750 0.750 0.850 1.000 1.000 1.000 1.000 0.900 0.900 %Released: 90 % PM 0.900 0.900 1.000 1.000 1.000 1.000 1.000 1.000 1.000 0.850 0.750 0.750 1/30/2020 7:53:10 PM EnergyGauge®/USRCZB v6.1 Page 4 Residential Equipment Selection Summary EnergyGauge 183 Seminole Remodel 1/30/2020 183 Seminole Rd Block 1, Heating Systeml, Cooling Systeml Atlantic Beach, FL Conditions Outdoor Winter Dry Bulb: 29 F Summer Dry Bulb: 95 F Summer Wet Bulb: 77 F Room Winter Dry Bulb: 70 F Summer Dry Bulb: 75 F RH: 55 % Air Entering Indoor Coil Winter Dry Bulb: 70 F Summer Dry Bulb: 76 F Summer Wet Bulb: 67 F Design Loads (Manual J or equivalent) Heating: 20.851 Sensible Cooling: 17.155 Latent Cooling: 5.954 Air Flow Estimate Heating CFM: 800 Cooling CFM: 800 Equipment Information - Heating Type: Electric Heat Pump Manufacturer: RUUD Nominal Capacity: 24.00 Outdoor Model: RP1524BJ1 AHRI Number: 201663456 Indoor Model: RH1T2417STANJA Equipment Information -Cooling Type: Electric Heat Pump Manufacturer: RUUD Speed: Single-Speed Outdoor Model: RP1524BJ1 AHRI Number: 201663456 Indoor Model: RH1T2417STANJA AHRI/Nominal Capacity: 24.00 OEM Capacity at Design Conditions Total Latent Sensible Sens plus excess Latent 25.3 8.9 16.4 17.9 Manual S Compliance-Cooling Cooling-Only Equipment or Cooling Mode of Heat Pump in Condition A Climate Total: Required: 90—115% Actual: 109 % Passes Manual S for Total PASS Latent: Required: 100—150% Actual: 149 % Manual S for Latent PASS Sensible: Required: 90%or more Actual: 104% Manual S for Sensible PASS Heat Pump equipment is sized for cooling. I hereby certify that Prepared by: 2020.01 .30 the equipment selected is in 19:59:14 accordance with ACCA Manual S. Date: I1'1'6 _05'00' Residential Equipment Selection Summary Manual S Heat Pump Supplemental Requirements EnergyGauge 183 Seminole Remodel 1/30/2020 183 Seminole Rd Block 1, Heating System1, Cooling System1 Atlantic Beach, FL Thermal Balance Point Design Temperature 29.0 'F 25 a AHRI Capacity Load at Design T 20.9 Mbtuh II Building Loads ? a Design Load Thermal Balance Point 33.6 °F f 15 AHRI/Nominal Capacity 24.00 Mbtuh OEM Capacity at design T 19.5 Mbtuh a 10 J Supplemental Heat Required * 1.4 Mbtuh (0.4KW) Supplemental Heat Installed 1.5 KW 20 30 40 50 60 % of supplemental requirement 129.5 % Outdoor Ai r tem p erature(F) % Required: 95% - 175% Passes Manual S supplemental heat requirement *The difference between the Manual J building load at design temperature and the Original Equipment Manufacter's published capacity at desigh temperature(ACOA Manual S,Section 2-11) Residential System Sizing Calculation Summary Project Title: 183 Seminole Rd 183 Seminole Remodel Atlantic Beach, FL 32233 1/30/2020 Location for weather data: Jacksonville, FL -Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidity data: Interior RH (50%) Outdoor wet bulb (77F) Humidity difference(49gr.) Winter design temperature(TMY3 99%) 29 F Summer design temperature(TMY3 99%) 95 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 41 F Summer temperature difference 20 F Total heating load calculation 20851 Btuh Total cooling load calculation 23410 Btuh Submitted heating capacity % of caic Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 115.1 24000 Sensible (SHR = 0.75) 103.1 18000 Heat Pump+Auxiliary(0.0kW) 115.1 24000 Latent 100.8 6000 Total (Electric Heat Pump) 102.5 24000 WINTER CALCULATIONS Winter Heating Load(for 1227 sqft) Load component Load ' Window total 149 sqft 2052 Btuh Wausi22.2%t z,angs 11,;, Wall total 973 sqft 4630 Btuh Door total 40 sqft 623 Btuh Ceiling total 1227 sqft 2407 Btuh l .".inag'''s=8H Floor total 1227 sqft 7015 Btuh Infiltration 35 cfm 1579 Btuh i Duct loss 2544 Btuh Subtotal 20851 Btuh I Ductsi122%1 Ventilation 0 cfm 0 Btuh Floors(33.6roi TOTAL HEAT LOSS 20851 Btuh SUMMER CALCULATIONS °00fS`3.0%j Summer Cooling Load (for 1227 sqft) Load component Load Window total 149 sqft 2835 Btuh I ;A;allsi;8.3%i Wall total 973 sqft 1944 Btuh rDo,rs12 %. Door total 40 sqft 471 Btuh Ceilingsi.6.5% Ceiling total 1227 sqft 1526 Btuh Infil.i6.2''.0i - • Floor total 0 Btuh Infiltration 26 cfm 578 Btuh Ducts(16.1%) 'A'indowsi12.1%i Internal gain 8120 Btuh Duct gain 1681 Btuh Sens.Ventilation 0 cfm ' 0 Btuh Blower Load 300 Btuh Blo,•iertI.3%i Total sensible gain 17455 Btuh Latent gain(ducts) 1 2080 Btuh Latent int(12.8°bI Latent gain(infiltration) I 875 Btuh Latent gain(ventilation) 0 Btuh Latent gain(internal/occupants/other) 3000 Btuh Int.Gain(34.7%) Total latent gain 5954 Btuh TOTAL HEAT GAIN I 23410 Btuh EnergyGauge®System Sizing 8th Edition PREPARED BY: 2020.01 .30 DATE: ry ivw 19:59:32 EnergyGauge®/USRCZB v6.1 wwwgetenergyforms.com _05'00' System Sizing Calculations - Summer Residential Load - Whole House Component Details Project Title: 183 Seminole Rd 183 Seminole Remodel Atlantic Beach, FL 32233 1/30/2020 Reference City: Jacksonville, FL Temperature Difference: 20.0F(TMY3 99%) Humidity difference: 49gr. Component Loads for Whole House Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 2 NFRC 0.25,0.35 No No W 1.2ft. 2.0ft. 25.5 0.0 25.5 12 31 792 Btuh 2 2 NFRC 0.25,0.35 No No S 1.2ft. 2.0ft. 18.0 18.0 0.0 12 14 220 Btuh 3 2 NFRC 0.25,0.35 No No S 1.2ft. 2.0ft. 6.0 6.0 0.0 12 14 73 Btuh 4 2 NFRC 0.25,0.35 No No N 1.2ft. 2.0ft. 26.0 0.0 26.0 12 12 318 Btuh 5 2 NFRC 0.25,0.35 No No N 1.2ft. 2.0ft. 9.0 0.0 9.0 12 12 110 Btuh 6 2 NFRC 0.19,0.32 No No E 1.2ft. 2.0ft. 6.0 0.0 6.0 10 25 148 Btuh 7 2 NFRC 0.19,0.32 No No E 1.2ft. 2.0ft. 40.0 0.0 40.0 10 25 987 Btuh 8 2 NFRC 0.19,0.32 No No N 1.2ft. 2.0ft. 18.0 0.0 18.0 10 10 187 Btuh Window Total 149 (sqft) 2835 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Concrete BIk,Hollow-Ext 0.13 5.0/0.0 142.5 2.1 300 Btuh 2 Concrete BIk,Hollow-Ext 0.13 5.0/0.0 272.0 2.1 573 Btuh 3 Concrete BIk.Hollow-Ext 0.13 5.0/0.0 281.0 2.1 592 Btuh 4 Frame-Wood-Ext 0.08 19.0/0.0 142.0 1.7 246 Btuh 5 Frame-Wood-Ext 0.08 19.0/0.0 76.7 1.7 133 Btuh 6 Frame-Wood-Ext 0.08 19.0/0.0 58.7 1.7 102 Btuh Wall Total 973 (sqft) 1944 Btuh Doors Type Area (sqft) HTM Load 1 Insulated-Exterior 20.0 11.8 236 Btuh 2 Insulated-Exterior 20.0 11.8 236 Btuh Door Total 40 (sqft) 471 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Unvented Attic/Light/Shingle 0.048 0.0/20.0 1227.0 1.24 1526 Btuh Ceiling Total 1227 (sqft) 1526 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 1227(ft-perimeter) 0.0 0 Btuh Floor Total 1227.0 (sqft) 0 Btuh Envelope Subtotal: 6776 Btuh Infiltration Type Average ACH Volume(cuft) Wall Ratio CFM= Load Natural 0.16 9816 1 26.3 578 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 7200 8120 Btuh Sensible Envelope Load: 15474 Btuh Duct load Average sealed,Supply(R6.0-Attic),Return(R6.0-Attic) (DGM of 0.109) 1681 Btuh Sensible Load All Zones 17155 Btuh EnergyGauge®/USRCZB v6.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 183 Seminole Rd 183 Seminole Remodel Atlantic Beach, FL 32233 1/30/2020 [r-101.E HOUSE TOTALS Sensible Envelope Load All Zones 15474 Btuh Sensible Duct Load 1681 Btuh Total Sensible Zone Loads 17155 Btuh Sensible ventilation 0 Btuh Blower 300 Btuh Whole House Total sensible gain 17455 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 875 Btuh Latent ventilation gain 0 Btuh Latent duct gain 2080 Btuh Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh Latent other gain 2200 Btuh Latent total gain 5954 Btuh TOTAL GAIN 23410 Btuh EQUIPMENT 1. Central Unit RUUD#RP1524BJ1 24000 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roller Shades(R)) Jbwwb - For Blinds:Assume medium color,half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen:none(N),Full(F)or Half(Y2)) f1Al1UNL J (Ornt-compass orientation) Version 8 EnergyGauge®/USRCZB v6.1 Page 2 System Sizing Calculations - Winter Residential Load - Whole House Component Details Project Title: 183 Seminole Rd 183 Seminole Remodel Atlantic Beach, FL 32233 Building Type: User 1/30/2020 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 41.0 F (TMY3 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 2, NFRC 0.25 Vinyi 0.35 W 25.5 14.3 366 Btuh 2 2, NFRC 0.25 Vinyl 0.35 S 18.0 14.3 258 Btuh 3 2, NFRC 0.25 Vinyl 0.35 S 6.0 14.3 86 Btuh 4 2, NFRC 0.25 Vinyl 0.35 N 26.0 14.3 373 Btuh 5 2, NFRC 0.25 Vinyl 0.35 N 9.0 14.3 129 Btuh 2, NFRC 0.19 Vinyl 0.32 E 6.0 13.1 79 Btuh 7 2, NFRC 0.19 Vinyl 0.32 E 40.0 13.1 525 Btuh 8 2, NFRC 0.19 Vinyl 0.32 N 18.0 13.1 236 Btuh Window Total 148.5(sqft) 2052 Btuh Walls 'Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Conc BIk,Hollow -Ext (0.132) 5.0/0.0 143 5.39 769 Btuh 2 l Conc BIk,Hollow - Ext (0.132) 5.0/0.0 272 5.39 1467 Btuh 3 Conc Blk,Hollow -Ext (0.132) 5.0/0.0 281 5.39 1516 Btuh 4 Frame-Wood - Ext (0.077) 19.0/0.0 142 3.17 450 Btuh 5Frame-Wood - Ext (0.077) 19.0/0.0 77 3.17 243 Btuh 6 I Frame-Wood - Ext (0.077) 19.0/0.0 59 3.17 186 Btuh Wall Total 973(sqft) 4630 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated - Exterior, n (0.380) 20 15.6 312 Btuh 2 Insulated - Exterior, n (0.380) 20 15.6 312 Btuh Door Total 40(sqft) 623Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/UShing (0.048) 0.0/20.0 1227 2.0 2407 Btuh Ceiling Total 1227(sqft) 2407Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 ' Slab On Grade (1.180) 0.0 145.0 ft(perim.) 48.4 7015 Btuh Floor Total 1227 sqft 7015 Btuh Envelope Subtotal: 16728 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.21 9816 1.00 35.0 1579 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Att) (DLM of 0.139) 2544 Btuh All Zones Sensible Subtotal All Zones 20851 Btuh l EnergyGauge®/USRCZB v6.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 183 Seminole Rd 183 Seminole Remodel Atlantic Beach, FL 32233 Building Type: User 1/30/2020 1INHOLE ©USi= TOTALS Subtotal Sensible Heat Loss 20851 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 20851 Btuh EQUIPMENT 1. Electric Heat Pump RUUD#RP1524BJ1 24000 Btuh Perordif Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear or'Tint(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) !� ori Version 8 EnergyGauge®I USRCZB v6.1 Page 2 ri `AN 6•91l2 5' 5.6 11: 13.0' I Ari. , .•1 114' 1'•717 relf ..7 Yr L A MD Eeti A101 air to 111 A' ® _ �' O Y kil �. i um o 4 ciED � _ r• '` \ , o-put 4s 'f i I : ',, Ti:::siza.jots) itc ! CD . [I +q I k 3E7 • •;, ,,tip - Q . QS4C•-X8 1(9`l SO _______ _ . MC. L i . ...'k 5 CD, H •i la' ,... 5.,:i., ',,, ', r ,aFf"'#/#1/"....4(4. 11/ 8 Li) ,,,ii ,-...,„„„,„.. . ,,,.. A , .:. II.a.lke 1.11 1 b. — o o Zd ... ..... •uW-it 107 ," 40IIIIII, c-47------ y r J e f 1 + h I. Vis ' \S\ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 jJ F31 r BUILDING REVIEW COMMENTS Date: 1/28/2020 _ Permit#: RESA19-0021 Site Address: 183 SEMINOLE RD Review Status: RE#: 170606 0000 Applicant: BOSCO BUILDING CONTRACTORS Property Owner: BERMAN HANNAH S ET AL Email: TODD@BOSCOCBC.COM Email: MBERMAN@MEDIASHARECONSULTING.COM Phone: 9042410320 Phone: 9048384962 9044228060 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Todd, at the time when the permit application was reviewed I was under the impression that replacing the HVAC system would just be a change out. That is not the case now. Energy calculation were submitted but they did not contain a DUCT SYSTEM SUMMARY REPORT and a duct layout floor plan which I customarily get with a new single family home. Because of the complete gutting of this house we should have treated this home that way and even terminated the power and got a temporary power pole. I need from Mr. Hammond 2 copies of the Duct Summary and the 2 copies of the duct layout. The duct summary report is usually generated with the energy calc software. 2. I also need to know why the AHRI number submitted on his hvac permit does not match the number that is recorded on the Manual S. They are supposed to. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904)247-5844 Email:mjones@coab.us Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with"clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. ALL Revision Request/Correction to Comments **HIGHLI HIGHLIGHTED ON rS'-�'�r�; HIGHLIGHTED IN J ` City of Atlantic Beach Building Department GRAY IS REQUIRED. n 800 Seminole Rd, Atlantic Beach, FL 32233 '.,- ,_,2).,,; Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT it, RESA19-0021 I I Revision to Issued Permit OR [1 Corrections to Comments Date:1/22/2020 Project Address: 183 Seminole Rd Contractor/Contact Name: Bosco Builders/Hammond Air Contact Phone: 904-398-6488 Email: Description of Proposed Revision/Corrections: JAN 2 2 2020 energy calculations I Bosco Builders/Hammond Air affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) •�Will proposed revision/corrections add additional square footage to original submittal? I ' INo n Yes (additional s.f. to be added: ) • ill proposed revision/corrections add additional increase in building value to original submittal? No n*Yes (additional increase in building value: $ )(Contractor must sign if increase in valuation) *Signature of Contractor/Agent: �� (Office Use Only) Approved IX Denied ❑ Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments ,UC r-rfe?TN 'v m wap W1 it.e.e '/.ed do/GT t !06(f/ael layo&i- •14•004.01 t Review Required: `i�� Building Planning& Zoning Reviewed By Tree Administrator Public Works f- ^ ° Public Utilities - 2- (V Public Safety Date Fire Services Updated10/17/18 Mechanical Permit Application "ALL INFORMATION HIGHLIGHTED IN _. i City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: .- 602.\ JOB ADDRESS: 1 U 3 -' t^r,. ..,,.1 t, -1)r. PROJECT VALUE $ O f))Op,°Q NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED) ,..,p►teco' tcco 0 Air Handling Equipment Only 0 Condenser OnlyAir Handling Unit& Condenser Air Conditioning: Unit Quantity I Tons per Unit 2_ Heat: Unit Quantity I BTUs per Unit Z`{po Seer Rating(REQUIRED) 1 ,.S Duct Systems: Total CFM v (REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION AR/#(REQUIRED) ❑Air Handling Equipment Only O Condenser Only 0 Air Handling Unit& Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating(REQUIRED) Duct Systems: Total CFM ❑FIRE PR VENTION Fire Spr nkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Undergound Fire Main Value (Requires 3 sets of plans) Fire Hoe Cabinets Quantity (Requires 3 sets of plans) Comme cial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) EFIRE PLACES (-'MISCELLANEOUS: Prefabricated Fireplace (Qty) Automobile Lifts Gas Piping Outlets Boilers BTUs Elevators/Escalators (ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps 44 Vented Wall Furnaces Refrigerator Condenser BTUs #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Narjie: _17p)4 JL r r1"*.c Phone Number: g0`e-14 i,-OSLO. I MechanicapCompany: 0in(rYrM a A, r C i�tc_...,:� Office Phone: 2r' -t9`t Fax racas-(DOE Co.Address: S11 1. CT \, let- -.?,c04., City:fpr k ,.1\e State:• Zip:S1a.D1 License Holder: rr ,a.0►,, )40Yre TQD State Certification/Registration# '_G, to.--,,U Notarized Signature of License Holder � �1-41.."6 The foregoing instrument was acknowledged before me this )-)" day of JciINWIy( ,20r,-, in the State of Florida, County of U,; , i- Signature of Notary Public----1 e--.-«- LQ•-�,.-----, onr'44. NANCY JANE DEMPSEY ,.. , Cornmbslon11GG30t012 [-] Personally Known OR [ ] Produced Identification 12,2023 • t2 EarpkesFrrDtuarYType of Identification: '•�,,v,lip U '4'4 mni D.42.4 Hobe'9orvkos Updated 10/9/18 FORM R405-2017 i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 183 Seminole Remodel Builder Name: Street: 183 Seminole Rd Permit Office: Duval City.State,Zip. Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: Design Location: FL.Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing Existing(Projecte 9. Wall Types(1161.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 820.00 ft' b Frame-Wood,Exterior R=19.0 341.33 ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 3 d.N/A R= ft' 10.Ceiling Types (1227.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 1227.00 ft' 6. Conditioned floor area above grade(ft') 1227 b.N/A R= ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft' 11.Ducts R ft' 7. Windows(148.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 110 a. U-Factor. Dbl,U=0.35 84.50 ft' SHGC: SHGC=0.25 b. U-Factor: Dbl,U=0.32 64.00 ft' 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.19 a.Central Unit 24.0 SEER:15.30 c. U-Factor N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a.Electric Heat Pump 24.0 HSPF:8.70 SHGC: Area Weighted Average Overhang Depth: 1.167 ft. Area Weighted Average SHGC 0.224 14.Hot water systems 8. Floor Types (1227,0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.940 a.Slab-On-Grade Edge Insulation R=0.0 1227.00 ft' b Conservation features b.N/A R= ft' None c.N/A R= ft' 15 Credits CF,Pstat Total Proposed Modified Loads: 38.52 PASS Glass/Floor Area: 0.121 A Total Baseline Loads: 39.80 I hereby certify that the plans and specifications covered by Review of the plans and O°'4-(11E ST41, this calculation are in compliance with the Florida Energy specifications covered by this ��°v�.""' ,Fpm Code. calculation indicates compliance o � , .T / with the Florida Energy Code. ,#-� �,, �{G;• PREPARED BY '"` ' .w 2019.10.16 Before construction is completed �_•w "d"�i ` i ?it DATE: h,46' 18:55:40-04'00' this building will be inspected for a c, ie (, it wy www go"n"g°`°''" co., compliance with Section 553.908 ; .`. ova r I hereby certify that this building,as designed, is in compliance Florida Statutes. Nati pmt. ��. 1 with the Florida Energy Code. ''sOv� 1SL , t,,' hC OWNER)AGENT BUILDING OFFICIAL: __ DATE: i DATE: ___. __ _ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACI-150(R402.4.1.2). 10/16/2019 6.42 PM EnergyGaugeAi USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4