Correction Comments
Setbacks: Section 24-67(c) requires a site plan showing setbacks. The shows setback lines but does not call out the location of projecting elements like porches. Please provide a site
plan showing setbacks from all new elements to property lines.
Side Walls Length: Section 24-172(c)(1) requires that second floor side walls be no longer than 35 feet in length without an architectural offset in the wall. A second floor side wall
exceeds 35 feet in length. Please revise plans accordingly.
Front Yard Projections: Section 24-83(b) limits front yard projections into front yard setbacks, including roof overhangs, to 48”. Please show that this requirement is being met or revise
plans accordingly.
Mechanical Equipment: Section 24-83(c) prohibits A/C and other mechanical equipment within the 5 foot side yard setback when adjacent to the living area of the neighboring property.
Please show that this requirement is being met or revise plans accordingly.
Shade Trees: Section 24-172(c)(4) requires 2 shade trees to be located on the property as part of the Old Atlantic Beach Design Standards. One of the trees must be located within the
front yard. This is the area within 20 feet of the property line along the street. The second tree can be located anywhere else on the lot. See Section 23-33(f)(f) for a list of approved
shade tree species.
Derek W. Reeves
Planner
dreeves@coab.us