ABBQ Plan Review Report 10.16.2019Permit Number: COMM17-0016
Site Address: 461 ATLANTIC BLVD
City, State Zip Code: Atlantic Beach, Fl 32233
Applied: 9/1/2017 Approved: 5/22/2018
Issued: 5/25/2018
Parent Permit:
Parent Project:
Applicant: <NONE>
Owner: ATLANTIC BEACH YARD REAL ESTATE LLC
Contractor: <NONE>
Description: construct single-story commercial restaurant - ABBQ
Finaled:
Status: ISSUED
Details:
11/21/2017. New permit application received; River City Contracting has taken over permit.
ABBQ
ATLANTIC BEACH BARBECUE
LIST OF REVIEWS
SENT DATE RETURNED
DATE DUE DATE TYPE CONTACT STATUS REMARKS
Review Group: 1ST REVIEW
10/27/2017 10/27/2017 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
NEW G001, G101, M102 - SENT TO ALL DEPT.'S
GEOTECH REPORT - SENT TO BUILDING
10/27/2017 11/6/2017 11/6/2017 ZONING Brian Broedell NOT APPLICABLE
TO DEPARTMENT
Notes:
10/27/2017 11/19/2017 11/6/2017 BUILDING Building DENIED
Notes:
Response to plan review comments is not from contractor of record and not complete.
Requested accurate contact information for contractor to continue plan review process.
Response to plan review comments is not from contractor of record and not complete.
Requested accurate contact information for contractor to continue plan review process.
10/27/2017 3/15/2018 11/6/2017 PUBLIC WORKS Public Works NOT APPLICABLE
TO DEPARTMENT Received 10/30/17
Notes:
10/27/2017 3/15/2018 11/6/2017 PUBLIC UTILITIES Public Utilities NOT APPLICABLE
TO DEPARTMENT Received 10/30/17
Notes:
Printed: Wednesday, 16 October, 2019 1 of 8
Permit Reviews
City of Atlantic Beach
10/27/2017 12/5/2017 11/6/2017 FIRE Fire DENIED
Notes:
See attached comments from JFRD. Per Hardy Padgett, Fire cannot approve this application until they receive a set of Civil Plans that have been fully
approved (by all departments) at COAB. Emailed comments to contractor 12/7/17 (alan@rivercity-contractors.com) - GM
5/25/2018 5/31/2018 6/4/2018 ZONING Brian Broedell APPROVED
Notes:
5/25/2018 5/25/2018 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
2 COPIES OF SITE PLAN
5/25/2018 2/28/2019 6/4/2018 BUILDING Building APPROVED
Notes:
Review Group: 2ND REVIEW
8/9/2018 8/9/2018 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
NEW SET OF DRAWINGS
CHANGE IN FINISHES, WOOD TRUSS SYSTEM, ENERGY CALCULATIONS
8/9/2018 8/30/2018 8/23/2018 ZONING Derek Reeves APPROVED
Notes:
8/9/2018 10/26/2018 8/23/2018 BUILDING Building APPROVED
W/CONDITIONS
Notes:
Still need truss engineering, store front, and Fla Product Approval
AND items from original approval
8/9/2018 8/10/2018 8/23/2018 PUBLIC WORKS Public Works NOT APPLICABLE
TO DEPARTMENT
Notes:
8/9/2018 8/13/2018 8/23/2018 PUBLIC UTILITIES Public Utilities NOT APPLICABLE
TO DEPARTMENT
Notes:
8/9/2018 9/5/2018 8/23/2018 FIRE Fire APPROVED
Notes:
contractor brought in approved drawings from JFRD, routed to Bldg. for review
Printed: Wednesday, 16 October, 2019 2 of 8
Permit Reviews
City of Atlantic Beach
Review Group: 3RD REVIEW
2/9/2018 2/9/2018 SUBMITTAL
COMPLETENESS Jennifer Johnston APPROVED
Notes:
receive response to comments dated 9/8/17, routed to Bldg., P&Z, PW, PU, & JFRD
2/12/18 - emailed JFRD for pickup
2/9/2018 3/15/2018 2/19/2018 ZONING Derek Reeves DENIED
Notes:
Parking: The proposed shared parking agreement has not been finalized and submitted. Provide a reference to the shared parking agreement in a
parking calculations table in the plans.
Seating: Parking discussions (see comment 1) have focused on a seating count of 150 seats. The plans submitted show far more than 150 seats. Note
that outside seating and bar seating are included in these calculations. It also appears that there are booths in the middle of the restaurant, but it is
unclear how many there are and what the seating capacity is for them. Please revise plans to show seating counts for the booths and so that the seating
count matches the parking provided.
Retaining Wall: A retaining wall is shown on page A001. Please provide details for retaining wall including height. Note that retaining wall height is
limited to 4 feet and that fences attached to the wall are considered part of the wall subject to the 4 foot height.
Tree Removal: An affidavit of no regulated tree removal was submitted with the revised submittal per a previous comment. It appears that several trees
exist on the site near the locations of proposed trees. Please confirm that no trees will be removed.
Landscape Buffer: Section 24-171(g)(1) requires a continuous line of shrubs in the 10 foot landscape buffer along Atlantic Boulevard. The shrubs must be
at least 2 feet tall. Please revise accordingly.
VUA Buffer: Section 24-177(d)(1)(b) requires a continuous line of shrubs between vehicle use areas and streets. The shrubs must be at least 3 feet tall.
The parking along Atlantic Boulevard is lacking this buffer.
2/9/2018 3/14/2018 2/19/2018 BUILDING Dan Arlington DENIED
Notes:
1. Please submit Florida Product Approval Sheets, per FAC 9B-72.
2. Please submit manufacturer’s data sheets and installation instructions for store-front windows and doors, barbecue and wood-burning appliances,
and any other cooking appliances not located under the type I hood, per FBC-M, Chapter 9.
3. Please submit steel bar joist engineering, signed off by EOR, as meeting his design.
4. The roof layout does not appear to provide the minimum separation between intake and exhaust vents, per FBC-M401.4.
5. Separate permits are required for MEPs, fuel gas, roofing, commercial hoods, and fire suppression systems.
6. Several commercial projects in this area have discovered unsuitable soils and buried trash on those sites. Soil tests and reports will be required if the
same is discovered on this site.
7. Rigid and spray foam plastic insulation are shown on drawings. Please submit documents showing the thermal and ignition barriers required by FBC-
B, Chapter 26, or ESRs for the specific foam products used.
8. Revised documents may generate additional comments.
2/9/2018 3/15/2018 2/19/2018 PUBLIC WORKS Public Works DENIED Received 2/12/18
Notes:
2/9/2018 3/16/2018 2/19/2018 PUBLIC UTILITIES Public Utilities NOT APPLICABLE
TO DEPARTMENT Received 2/12/18
Notes:
Printed: Wednesday, 16 October, 2019 3 of 8
Permit Reviews
City of Atlantic Beach
Review Group: 4TH REVIEW
3/1/2018 3/1/2018 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
George Harlow @ Baker and Klein spoke with Hardy Padgett at COJ Fire and was told they denied the last review because they needed a fire flow test.
George emailed this to myself and Hardy for review. I emailed Hardy a new routing sheet for this review and asked him to send it back signed as
approve if it passes review.
5/22/18 - added Building, P&Z, PW, & PU to 4th review group as correction comments received applied to other departments' comments
3/1/2018 3/2/2018 3/12/2018 FIRE Fire APPROVED
Notes:
Approved by COJ Fire (Padgett) 3/2/18. See Attached approval.
5/22/2018 5/24/2018 6/1/2018 BUILDING Building APPROVED
W/CONDITIONS
Notes:
5/22/2018 5/22/2018 6/1/2018 PUBLIC WORKS Public Works APPROVED
W/CONDITIONS
Notes:
See Conditions of Approval that will be printed on Permit.
5/22/2018 5/22/2018 6/1/2018 PUBLIC UTILITIES Public Utilities APPROVED
W/CONDITIONS
Notes:
See Conditions of Approval that will be printed on Permit.
5/22/2018 5/24/2018 6/1/2018 ZONING Derek Reeves APPROVED
W/CONDITIONS
Notes:
Seating count is limited to 150 seats. A revised life safety plan was submitted that meets the seating count but other pages were not updated.
The retaining wall and fencing cannot be connected.
Shrubs along Atlantic Blvd need to be extended to the west.
Shrubs along the VUA need to be extended towards the east.
Review Group: AUTO
9/1/2017 9/1/2017 SUBMITTAL
COMPLETENESS Jennifer Johnston APPROVED
Notes:
Printed: Wednesday, 16 October, 2019 4 of 8
Permit Reviews
City of Atlantic Beach
9/1/2017 10/12/2017 9/11/2017 BUILDING Building DENIED
Notes:
Correction Comments:
Application is disapproved for the following issues:
1. Parking and loading spaces appear to be inadequate for 176 occupants. Please review COAB Land Development Regulations, Section 24-161 and
show how parking and loading complies with COAB Regulations.
2. Please submit Florida Product Approval Sheets, per FAC 9B-72.
3. Please provide the approved set of plans, stamped by the Fire Marshal’s Office and a final approval from the private provider plans examiner.
4. Please submit manufacturer’s data sheets and installation instructions for store-front windows and doors, barbecue and wood-burning appliances,
and any other cooking appliances not located under the type I hood, per FBC-M, Chapter 9.
5. Please submit steel bar joist engineering, signed off by EOR, as meeting his design.
6. The roof layout does not appear to provide the minimum separation between intake and exhaust vents, per FBC-M401.4.
7. Separate permits are required for MEPs, fuel gas, roofing, commercial hoods, and fire suppression systems.
8. Several commercial projects in this area have discovered unsuitable soils and buried trash on those sites. Soil tests and reports will be required if the
same is discovered on this site.
9. Rigid and spray foam plastic insulation are shown on drawings. Please submit documents showing the thermal and ignition barriers required by FBC-
B, Chapter 26, or ESRs for the specific foam products used.
10. Revised documents may generate additional comments.
Correction Comments:
Application is disapproved for the following issues:
1. Parking and loading spaces appear to be inadequate for 176 occupants. Please review COAB Land Development Regulations, Section 24-161 and
show how parking and loading complies with COAB Regulations.
2. Please submit Florida Product Approval Sheets, per FAC 9B-72.
3. Please provide the approved set of plans, stamped by the Fire Marshal’s Office and a final approval from the private provider plans examiner.
4. Please submit manufacturer’s data sheets and installation instructions for store-front windows and doors, barbecue and wood-burning appliances,
and any other cooking appliances not located under the type I hood, per FBC-M, Chapter 9.
5. Please submit steel bar joist engineering, signed off by EOR, as meeting his design.
6. The roof layout does not appear to provide the minimum separation between intake and exhaust vents, per FBC-M401.4.
7. Separate permits are required for MEPs, fuel gas, roofing, commercial hoods, and fire suppression systems.
8. Several commercial projects in this area have discovered unsuitable soils and buried trash on those sites. Soil tests and reports will be required if the
same is discovered on this site.
9. Rigid and spray foam plastic insulation are shown on drawings. Please submit documents showing the thermal and ignition barriers required by FBC-
B, Chapter 26, or ESRs for the specific foam products used.
10. Revised documents may generate additional comments.
9/1/2017 9/29/2017 9/11/2017 FIRE Fire DENIED
Notes:
see attached comments from JFRD
9/1/2017 9/8/2017 9/11/2017 ZONING Brian Broedell DENIED
Notes:
Rear setbacks and side setbacks.
Dumpster screening.
Fence heights.
Tree Removal.
Loading Zone.
Dimensions for ADA parking spot.
Bathroom setbacks.
Not enough parking spaces.
Irrigation Plan.
Landscaping Plan insufficient.
Shared Parking.
Printed: Wednesday, 16 October, 2019 5 of 8
Permit Reviews
City of Atlantic Beach
9/1/2017 3/15/2018 9/11/2017 PUBLIC WORKS Public Works DENIED Received 9/27/17
Notes:
Provide impervious surface calculations for entire lot (existing and post construction).
Maximum driveway width within the City right-of-way is 20'.
Provide a detailed plan of water retention area and how water runoff gets to water retention areas and then to street.
Documentation shows impervious areas are over the 70% allowed by City code.
See Conditions of Approval that will be printed on Permit.
See Attachment - Letter emailed to Contractor.
9/1/2017 3/16/2018 9/11/2017 PUBLIC UTILITIES Public Utilities DENIED Received 9/27/17
Notes:
See Attachment - Letter and Plan Corrections per Sheet Number C-001 and Sheet Number C-120 emailed to Contractor.
See Conditions of Approval that will be printed on Permit.
See Attachment - New Water/Sewer Tap Request.
Review Group: REVISION
12/7/2018 12/7/2018 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
TRUSS ENGINEERING
12/7/2018 2/28/2019 12/21/2018 BUILDING Building APPROVED
Notes:
1/10/2019 1/10/2019 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
FURNISHED METAL AND PVC ROOFING
STUCCO, STORE FRONT DATA
1/10/2019 2/28/2019 1/25/2019 BUILDING Building APPROVED
Notes:
1/25/2019 1/25/2019 SUBMITTAL
COMPLETENESS Jennifer Johnston APPROVED
Notes:
received roof panel report for porch & metal roofing - routed to Bldg.
1/25/2019 2/28/2019 2/8/2019 BUILDING Building APPROVED
Notes:
3/6/2019 3/6/2019 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
MECH DUCT SIZE CHANGES
Printed: Wednesday, 16 October, 2019 6 of 8
Permit Reviews
City of Atlantic Beach
MOVED TO ACRS18-0506
3/6/2019 3/12/2019 3/20/2019 BUILDING Building APPROVED
Notes:
Per D. Arlingtons request and approval, MJones signed off on revision.
3/15/2019 3/15/2019 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
STRUCTURAL ATTACHMENT ENGINEERING
3/15/2019 3/22/2019 3/29/2019 BUILDING Building APPROVED
Notes:
letter from engineer.
4/29/2019 4/29/2019 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
APPROVED LIFE SAFETY PLAN FROM FIRE
G101
4/29/2019 5/14/2019 5/13/2019 BUILDING Building APPROVED
Notes:
4/29/2019 4/29/2019 5/13/2019 FIRE Fire APPROVED
Notes:
BROUGHT IN BY CONTRACTOR
6/11/2019 6/11/2019 SUBMITTAL
COMPLETENESS Permit Tech APPROVED
Notes:
OHM DESCRIPTION
OFFICE COPY
6/11/2019 10/3/2019 6/25/2019 BUILDING Building APPROVED
Notes:
OHM DESCRIPTION
10/3/2019 10/3/2019 SUBMITTAL
COMPLETENESS Jennifer Johnston APPROVED
Notes:
received revised final survey/as-builts - routed to Bldg., P&Z, PW, & PU
10/3/2019 10/17/2019 ZONING Zoning
Notes:
Printed: Wednesday, 16 October, 2019 7 of 8
Permit Reviews
City of Atlantic Beach
10/3/2019 10/9/2019 10/17/2019 BUILDING Building APPROVED CO Inspection
Notes:
Survey approved.
CO inspection disapproved.
CERTIFICATE OF OCCUPANCY INSPECTION
1. (3) Unpermitted sheds, refrigeration equipment, and extension cords used for permanent wiring in
the West side yard.
Three issues:
A. Extension cords used for permanent wiring are a Safety and Fire Hazard and must be removed immediately, per IPMC 605.4 and NEC 400.8.
Permanent building wiring can be installed by a licensed electrical contractor. Electrical permit required.
B. Refrigeration equipment has not been approved or permitted in the 5-foot west side yard.
Please submit approval documents from Fire Marshal’s Office, Department of Hotels and Restaurants, and COAB Zoning Department. Food storage
outside of the building must be approved by the Department of Hotels and Restaurants.
C. (3) sheds have not been approved or permitted in the 5-foot west side yard. If location is approved by Zoning, please submit engineering and tie-
down documents and apply for building permit. Sheds must be approved by Zoning, permitted, and anchored to resist wind loads. See Zoning
comments.
10/3/2019 10/17/2019 PUBLIC WORKS Public Works
Notes:
10/3/2019 10/17/2019 PUBLIC UTILITIES Public Utilities
Notes:
Printed: Wednesday, 16 October, 2019 8 of 8
Permit Reviews