Loading...
1756 Live Oak Ln Insulation / Evaluation AMERICA INSULATOR LLC Spray Foam Insulation Builders Statement Vet" Ic e FlomeS BUILDER / HOMEOWNER LOT# SUBDIVISION n oo, c Loln1 e_ JOB ADDRESS LOCATION THICKNESS R-VALUF OPEN CELL CLOSED CELL ROOFLINE b . C /ES0207 �`1 ❑ KNEEWALLS I,. 0 c ❑ UNDERFLOOR ❑ ❑ CRAWLSPACE ❑ ❑ HEADER BANDS ❑ ❑ WALLS _ ❑ ❑ American Insulators, LLC ' c8 SPRAY FOAM INSTALLED BY (COMPANY NAME) DATE INSTALLED SPRAY FOAM INSTALLER NAME (PRINT) SIGNATURE s E .." Q . C � I 1 �oovv. FOAM MANUFACTURER FOAM ITEM # PC - 3) 5 gR v ) Bosner FOAM MANUFACTURER FOAM ITEM # 6935 Distribution Avenue South • Jacksonville, Florida 32256 • Phone (904) 268-4588 • Fax (904) 268-6501 ' .._ ICC ESEVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 Reissued August 2019 This report is subject to renewal August 2020. www.icc-es.org (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE 3.0 DESCRIPTION PROTECTION 3.1 General: Section: 07 21 00—Thermal Insulation SucrasealTM 0.5 spray foam insulation is a two- REPORT HOLDER: component, open cell, one-to-one-by-volume spray- applied polyurethane foam system with a nominal density SES FOAM of 0.5 pcf (8.0 kg/m3). The insulation's liquid components are supplied in nominally 55-gallon drums, labeled as "A" EVALUATION SUBJECT: component or "B" component. The insulation components have a shelf life of six months when stored in unopened SUCRASEALTM 0.5 AND SES FOAM 0.5 LB SPRAY: containers at temperatures between 70°F (21°C) and 90°F SPRAY-APPLIED POLYURETHANE FOAM PLASTIC (32°C). INSULATION The attributes of the insulation have been verified as conforming to the provisions of ICC 700-2008 Section 1.0 EVALUATION SCOPE 703.2.1.1.1(c) as an air impermeable insulation. Note that 1.1 Compliance with the following codes: decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific • 2012 and 2009 International Building Code®(IBC) provisions that may be contingent upon meeting specific • 2012 and 2009 International Residential Code®(IRC) conditions, and the verification of those conditions is outside the scope of this report. These codes or standards • 2012 and 2009 International Energy Conservation often provide supplemental information as guidance. Code®(I ECC) 3.2 Surface-burning Characteristics: ■ Other Codes(see Section 8.0) At a maximum thickness of 4 inches (102 mm) and a Properties evaluated: nominal density of 0.5 pcf, the insulation has a flame- • Surface-burning characteristics spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84. ■ Physical properties Thicknesses for wall cavities and ceiling cavities are not • Thermal resistance (R-values) limited when the insulation is covered with a minimum 1/2-inch-thick (12.7 mm) gypsum board installed in • Air permeability accordance with the applicable code. • Exterior walls in Types I-IV construction 3.3 Thermal Resistance(R-values): 1.2 Evaluation to the following green standard: The insulation has thermal resistance (R-values)at a mean • 2008 ICC 700 National Green Building Standard (ICC temperature of 75°F(24°C)as shown in Table 1. 700-2008) 3.4 Air Permeability: Attributes verified: The insulation, at a minimum thickness of 3 inches • See Section 3.1 (76 mm), is considered air-impermeable in accordance with IRC Section R202, based on testing in accordance 2.0 USES with ASTM E283. SucrasealTM 0.5 spray polyurethane foam plastic insulation 3.5 DC 315 Coating: is used as a nonstructural thermal insulating material in DC 315 Coating is manufactured by International Fireproof buildings of Type I, II, Ill, IV and V (IBC) construction, and Technology, Inc. / Paint to Protect Inc. (ESR-3702), and is in dwellings built under the IRC. The insulation is for use in a water-based intumescent coating supplied in 5-gallon wall cavities and floor/ceiling assemblies, and in attics and (19 L) pails and 55-gallon (208 L) drums and has a shelf crawl spaces when installed as described in Section 4.4. life of six months when stored in a factory-sealed container Under the IRC, the insulation may be used as air- at temperatures between 50°F(10°C)and 80°F(27°C). impermeable insulation when installed as described in Section 3.4. SES Foam 0.5 lb Spray is identical to 3.6 FireShell®F10E: SucrasealTy 0.5. Wherever SucrasealT"" 0.5 is mentioned, FireShell® F10E is manufactured by TPR2 Corporation the same property applies to SES Foam 0.5 lb Spray. (ESR-3997), and is a water-based coating supplied in ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as �� to any finding or other matter in this report,or as to any product covered by the report. . _ 5-gallon (19 L)pails and 55-gallon(208L)drums and has a minimum thickness of 20.0 mils (0.51 mm) wet film shelf life of one year when stored in a factory-sealed thickness [14 mils (0.36 mm) dry film thickness] with a container at temperatures between 45°F (7.2°C) and 90°F minimum application rate of 1.25 gal/100 ft2. The coating (35°C). must be applied over the SucrasealT" 0.5 insulation in 4.0 INSTALLATION accordance with the coating manufacturer's published instructions and this report. Surfaces to be coated must be 4.1 General: dry, clean and free of dirt, loose debris and other Sucrasealm 0.5 spray insulation must be installed in substances that could interfere with adhesion of the accordance with the manufacturer's published installation coating. The coating is applied in one or more coats with instructions and this report. A copy of the manufacturer's brush, roller or airless spray equipment. published installation instructions must be available at all 4.4 Attics and Crawl Spaces: times on the jobsite during installation. 4.4.1 Application with a Prescriptive Ignition Barrier: 4.2 Application: When SucrasealTm 0.5 spray is installed within attics and The insulation is spray-applied at the jobsite using a crawl spaces, where entry is made only for service of volumetric positive displacement pump as identified in the utilities, an ignition barrier must be installed in accordance SucrasealTm 0.5 spray application manual. The insulation with IBC Section 2603.4.1.6 or IRC Section R316.5.3 or components must be stored at temperatures between R316.5.4, as applicable, except when the installation is in 70°F (21°C) and 90°F (32°C) for several days before accordance with Section 4.4.2 or Section 4.4.3. The application. The insulation must not be used in areas that ignition barrier must be consistent with the requirements have maximum in-service temperatures greater than 180°F for the type of construction required by the applicable (82°C). The insulation must not be used in electrical outlet code, and must be installed in a manner so that the foam or junction boxes or in contact with water (e.g., rain, plastic insulation is not exposed. SucrasealTN 0.5 spray condensation, ice, snow) or soil. The substrate must be insulation at a minimum thickness of 3 inches (76 mm) free of moisture, frost or ice, loose scales, rust, oil, grease may be installed in unvented attics in accordance with or other surface contaminants. The insulation can be 2012 IRC Section R806.5 (2009 IRC Section R806.4), as installed in one pass to the maximum thickness. The applicable. spray-applied foam insulation must be protected from 4.4.2 Application without a Prescriptive Ignition weather during and after installation. Barrier: Where the spray-applied insulation is installed in 4.3 Thermal Barrier: accordance with this section or Section 4.4.3, the following 4.3.1 Application with a Prescriptive Thermal Barrier: conditions apply: SucrasealTm 0.5 spray insulation must be separated from a) Entry to the attic or crawl space is to service utilities, the interior of the building by an approved thermal barrier and no storage is permitted. of /2-inch-thick (12.7 mm) gypsum wallboard or an equivalent 15-minute thermal barrier complying with, and b) There are no interconnected attic or crawl space installed in accordance with, IBC Section 2603.4 or IRC areas. Section R316.4, as applicable, except when the installation c) Air in the attic or crawl space is not circulated to other is in accordance with Section 4.3.2.Within an attic or crawl parts of the building. space, installation must be in accordance with Section 4.4. d) Attic ventilation is provided when required by IBC 4.3.2 Application without a Prescriptive Thermal Section 1203.2 or IRC Section R806, except when Barrier: The prescriptive 15-minute thermal barrier may be air-impermeable insulation is permitted in unvented omitted when installation is in accordance with this section. attics in accordance with 2012 IRC Section R806.5 or The insulation and coating may be spray-applied to the 2009 IRC Section R806.4. Under-floor (crawl space) interior facing of walls and the underside of roof sheathing ventilation is provided when required by IBC Section or roof rafters, and in crawl spaces, and may be left 1203.3 or IRC Section R408.1,as applicable. exposed as an interior finish without a prescribed 15-minute thermal barrier or prescribed ignition barrier e) Combustion air is provided in accordance with when the installation is in accordance with either Sections International Mechanical Code®Section 701. 4.3.2.1 or 4.3.2.2. In attics, the insulation may be spray-applied to the 4.3.2.1 Application with DC 315 Coating: The thickness underside of roof sheathing or roof rafters, and/or vertical of the foam plastic applied to the underside of roof surfaces, and in crawl spaces the insulation may be spray- sheathing and to vertical wall surfaces must not exceed applied to the underside of floors and/or vertical surfaces 111/2 inches (292 mm). The foam plastic must be covered as described in this section. The thickness of the foam on all surfaces with DC 315 Coating (ESR-3702) at a plastic applied to the underside of the top of the space minimum thickness of 18.0 mils (0.47 mm) wet film must not exceed 12 inches(305 mm). The thickness of the thickness [12 mils (0.30 mm) dry film thickness] with a foam plastic applied to vertical surfaces must not exceed minimum application rate of 1.12 gal/100 ft2. The coating 111/2 inches (292 mm). The foam plastic may be installed must be applied over the SucrasealTm 0.5 insulation in without a covering or coating. The insulation may be accordance with the coating manufacturer's published installed in unvented attics in accordance with 2012 IRC instructions and this report. Surfaces to be coated must be Section R806.5 (2009 IRC Section R806.4). The ignition dry, clean and free of dirt, loose debris and other barrier in accordance with IBC Section 2603.4.1.6 or IRC substances that could interfere with adhesion of the Section R316.5.3 may be omitted. coating. The coating is applied in one or more coats with 4.4.3 Use on Attic Floors: SucrasealTM' 0.5 spray brush, roller or airless spray equipment. insulation may be installed exposed at a maximum 4.3.2.2 Application with FireShell®F10E: The thickness thickness of 111/2 inches (292 mm) between joists in attic of the foam plastic applied to the underside of roof floors. The ignition barrier in accordance with IBC Section sheathing and to vertical wall surfaces must not exceed 2603.4.1.6 or IRC Section R316.5.3 may be omitted. The 111/2 inches (292 mm). The foam plastic must be covered insulation must be separated from the interior of the 4.5 Exterior Walls of Type I, II, III and IV Construction: 6.5 Report of fire propagation testing in accordance with 4.5.1 General: When used on walls of Type I, II, Ill and IV NFPA 285. exterior wall construction, the SucrasealTM 0.5 spray- 6.6 Engineering evaluation extending NFPA 285 testing applied foam insulation must comply with Section to various exterior wall constructions. 2603.5 of the IBC and this section. The potential heat 7.0 IDENTIFICATION of SucrasealT"" 0.5 spray-applied foam insulation is 466 Btu/ft2 (5.26 MJ/m2) per inch of thickness when tested 7.1 Components of the SucrasealT"^ 0.5 spray in accordance with NFPA 259. polyurethane foam plastic insulation are identified with the manufacturer's name (SES Foam) and address; 4.5.2 Specific Wall Assemblies: Wall assemblies must the date of manufacture or the lot number;the product be as described in Table 2. trade name(SucrasealT"" 0.5); the mixing instructions; 5.0 CONDITIONS OF USE the density; the flame-spread and smoke-developed The SucrasealT"" 0.5 spray polyurethane foam plastic indices; and the evaluation report number (ESR- insulation described in this report complies with, or is a 3375). suitable alternative to what is specified in, those codes International Fireproof Technology, Inc. / Paint to listed in Section 1.0 of this report, subject to the following Protect Inc., DC 315 Coating is labeled with the conditions: manufacturer's name and address; the product name; 5.1 The insulation must be installed in accordance with the date of manufacture, the shelf life or expiration the manufacturer's published installation instructions, date; the manufacturer's instructions for application this evaluation report and the applicable code. If there and evaluation report number(ESR-3702). are any conflicts between the manufacturer's TPR2 Corporation Fireshell F10E coatings and published installation instructions and this report, this Blazelok TBX coating is labeled with the report governs. manufacturer's name and address; the product name; the date of manufacture, the shelf life or expiration 5.2 The insulation must be separated from the interior of date; the manufacturer's instructions for application the building by an approved 15-minute thermal and evaluation report number(ESR-3997). barrier, as described in Section 4.3.1, except when the installation is in accordance with Section 4.3.2. 7.2 The report holder's contact information is the Installation in an attic or crawl space must be as following: described in Section 4.4. SES FOAM 5.3 The insulation must not exceed the thicknesses noted 4008 LOUETTA ROAD,#538 in Sections 3.2,4.3, and 4.4. SPRING,TEXAS 773884405 (713)239-0252 5.4 The insulation must be protected from exposure to the www.sesfoam.com weather during and after application. 8.0 OTHER CODES 5.5 The insulation must be applied by contractors certified by SES Foam. In addition to the codes referenced in Section 1.0, the products in the report were evaluated for compliance with 5.6 Use of the insulation in areas where the probability of the requirements of the following codes: termite infestation is "very heavy" must be in accordance with 2012 IBC Section 2603.9 (2009 IBC • 2006 International Building Code® Section 2603.8)or IRC Section R318.4, as applicable. • 2006 International Residential Code® 5.7 Jobsite certification and labeling of the insulation must • 2006 International Energy Conservation Code® comply with IRC Sections N1101.4 and N1101.4.1 The products comply with the above mentioned codes as and IECC Sections R303.1.1 and 303.1.1.1, as described in Sections 2.0 through 7.0 of this report, with applicable. revisions as noted below: 5.8 When use is on exterior wall of buildings of Type I, II, • Application with and without a Prescriptive Thermal III or IV construction, construction must be as Barrier: See Section 4.3, except the approved thermal described in Section 4.5 and Table 2. barrier must be installed in accordance with Section 5.9 A vapor retarder must be installed in accordance with R314.4 of the 2006 IRC. the requirements of the applicable code. • Application with a Prescriptive Ignition Barrier: See 5.10 Sucrasealrm 0.5 spray polyurethane foam plastic Section 4.4.1, except an ignition barrier must be insulation is produced in St. Louis, Missouri, under a installed in accordance with Section R314.5.3 or quality-control program with inspections by ICC-ES. R314.5.4 of the 2006 IRC. 6.0 EVIDENCE SUBMITTED ■ Application without a Prescriptive Ignition Barrier: 6.1 Data in accordance with the ICC-ES Acceptance See Section 4.4.2, except that combustion air is Criteria for Spray-applied Foam Plastic Insulation provided in accordance with Sections 701 and 703 of (AC377), dated April 2016, including reports of tests the 2006 IECC. in accordance with Appendix X of AC377. ■ Protection against Termites: See Section 5.6, except 6.2 Reports of room corner fire-testing in accordance with use of the insulation in areas where the probability of NFPA 286. termite infestation if"very heavy" must be in accordance with Section R320.5 of the 2006 IRC. 6.3 Report of air permeance testing in accordance with • Jobsite Certification and Labeling: See Section 5.7, ASTM E283. except jobsite certification and labeling must comply 6.4 Report of potential heat testing in accordance with with Sections 102.1.1 and 102.1.1.1, as applicable, of NFPA 259. the 2006 IECC. TABLE 1—THERMAL RESISTANCE(R-VALUES'2) THICKNESS(inches) R-VALUE(°F•ft2•h/Btu) 1 4.0 2 7.6 3 11 3.5 13 4 15 5 19 6 22 7 26 8 30 9 33 10 37 11 41 12 44 For SI: 1 inch=25.4 mm,1°F•ft2•h/Btu=0.176 110K•m2/W. 1R-values are calculated based on tested K values at 1-and 3.5-inch thicknesses. 2R-values greater than 10 are rounded to the nearest whole number. TABLE 2—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WALL COMPONENT MATERIALS 1 –Concrete wall 2–Concrete Masonry wall Base wall system–Use either 3–1 layer of 5/8-inch thick Type X gypsum wallboard installed on the interior side of minimum 3-5/8 inch 1,2,or 3 deep minimum 20 gauge thick steel studs spaced a maximum of 24-inch on center. Lateral bracing installed minimum every 4 ft.vertically or as required.Wall stud cavities shall be filled at each floor line with minimum 4 lb/ft3 mineral-fiber insulation friction fit between steel wall studs. Resilient Channel–For use 1 –None with Base Wall System 3 above 2–Double leg"hat"shaped steel resilient channel installed perpendicular to the wall studs(interior side –Use either 1 or 2 only)and spaced a maximum of 24-inches on center between steel studs and Type X gypsum wallboard. Entire perimeter of window opening to be framed with resilient channel. Perimeter Fire Barrier System Perimeter fire barrier system complying with Section 715.4 of the 2012 IBC shall be installed to fill the void between the edge of the concrete floor slab and the interior surface of the exterior wall assembly. Full wall stud cavity depth or less of SucraSealTM 0.5 spray-applied foam plastic insulation applied using Wall Stud Cavity Insulation exterior gypsum sheathing as the substrate and covering the width of the cavity and the inside of the steel wall stud framing flange. Exterior sheathing–For Base5/8-inch thick Type X exterior type gypsum sheathing complying with ASTM C1177. Wall System 3 above 1–Any non-combustible exterior wall covering material Exterior Wall Covering–Use 2–Any non-combustible exterior wall covering system with a combustible WRB that has successfully been either 1,2,or 3 tested in accordance with NFPA 285. (see Note 1 below) 3–Metal Composite Material(MCM)Mitsubishi Plastic Composites America,Inc.,Alpolic/fr wall panels (see ICC-ES ESR-2653)or Alcoa Architectural Products Reynobond FR 6-mm panels(see ICC-ES ESR- 3435)where there is no exterior insulation in the cavity behind the panels. Flashing of window,door and As an option,flash around window,door and other exterior penetrations with limited amounts of maximum other exterior wall penetrations. 12-inch wide acrylic,asphalt or butyl-based flashing tape or liquid applied membrane material. For SI: 1 inch=25.4 mm;1 pcf=16.0 kg/m3. Note 3:Exterior wall coverings shall be installed in accordance with the manufacturer's installation requirements and must comply with the applicable provisions of IBC Chapter 14 and IRC Chapter 7. ES ° Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3702 Reissued February 2019 Revised June 2019 This report is subject to renewal February 2021. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 09 00 00—FINISHES life of 2 years when stored in factory-sealed containers at Section: 09 96 43—Fire-Retardant Coatings temperatures between 50°and 80°F(10 and 27°C). REPORT HOLDER: DTM Bonding Primer is a waterborne, acrylic emulsion, bonding primer manufactured by Sherwin-Williams. The INTERNATIONAL FIREPROOF TECHNOLOGY INC. primer is supplied in 1- and 5-gallon (3.8 and 18.9 L) containers, and has a shelf life of three (3) years when EVALUATION SUBJECT: stored in factory-sealed containers at temperatures between 50°and 100°F(10 and 38°C). DC315 INTUMESCENT COATING 3.2 Vapor Retarder: 1.0 EVALUATION SCOPE When a minimum thickness of 18 mils WFT [0.018 inch (0.46 mm)] of DC315 is apllied to a minimum thickness of Compliance with the following codes: 2 inches (50.8 mm)of open-cell spray-applied foam plastic • 2018, 2015, 2012, 2009 and 2006 International Building insulation, the assembly has a vapor permeance greater Code®(IBC) than 1 and less than 10 perms (5.7x10 kg/Pa-s-m2) when tested in accordance with ASTM E96 procedure A • 2018, 2015, 2012, 2009 and 2006 International (dessicant method), and qualifies as a Class III vapor Residential Code®(IRC) retarder, Properties evaluated: 3.3 Surface Burning Characteristics: • Application without a prescriptive thermal barrier When tested in accordance with ASTM E84/UL 723, at a • thickness of 13 mils WFT [0.013 inch (0.33 mm)], DC315 Application without a prescriptive ignition barrier has a flame spread index of 25 or less and a smoke- • Physical properties developed index of 450 or less. The DC315 coated foam • Surface burning characteristics assemblies listed in Table 1 were tested in accordance with NFPA 286 and comply with the acceptance criteria of • Water vapor transmission 2018 IBC Section 803.1.1.1 (2015, 2012 and 2009 IBC 2.0 USES Section 803.1.2.1 and 2006 IBC Section 803.2.1) and 2018, 2015, 2012 and 2009 IRC R302.9.4 (2006 IRC DC315 is a liquid-applied coating intended for application Section R315.4)and is permitted to be used where a Class over the surface of spray-applied foam plastic insulation A classification in accordance with ASTM E 84 or UL 723 complying with ICC-ES Acceptance Criteria for Spray- is required by 2018 IBC Section 803.13 (2015 IBC Section applied Foam Plastic Insulation (AC377). The coated 803.11, 2012 and 2009 IBC Section 803.9 and 2006 IBC assembly may be left exposed to the interior of the building Section 803.5). without the application of a code-prescribed thermal barrier 4.0 DESIGN AND INSTALLATION when installed as described in Sectoin 4.2 of this report. The DC315 coating may be used in attic and crawl spaces 4.1 Installation–General: as described in Section 4.3 of this report. DC315 must be applied in accordance with the 3.0 DESCRIPTION manufacturer's published application instructions and this 3.1 General: report. A copy of the instructions must be available on the job site at all times. DC315 is a single-component, water-based, liquid-applied DC315 must be mechanically mixed prior to application. intumescent coating and are available in white, ice gray, The coating is applied to the required thickness using dark gray and charcoal black. The coating is supplied in spray equipment, a brush or a roller having a medium nap. 5-gallon (19 L) pails and 55 gallon (208 L) drums, and has Surfaces to be coated must be inspected in accordance a shelf life of one (1) year when stored in factory-sealed with the manufacturer's published installation instructions containers at temperatures between 50° and 80°F (10 and and must be dry, clean, and free of dirt, loose debris and 27°C). other substances that could interfere with the adhesion of DC315 Primer is a liquid-applied primer, manufactured the coating. The coating must not be applied when the by International Fireproof Technology, Inc., and is supplied ambient or surface temperature is below 50°F (10°C) or in 1- and 5-gallon (3.8 and 18.9 L) pails, and has a shelf above 90°F (32° C) and relative humidity of more than ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i S, to any finding or other matter in this report,or as to any product covered by the report. � �. 85%. The manufacturer must be consulted for specific 5.1 Application must comply with this report, the application conditions. manufacturer's published installation instructions, and 4.2 Application without a Prescriptive Thermal the applicable code. A copy of the installation Barrier: instructions must be on the job site during application of the coating. In the event of a conflict, this report The DC315 coating may be applied over spray-applied and the code govern. foam plastic insulations listed in Table 1 without covering 5.2 The application of additional interior finishes over the the coated assembly with the thermal barrier prescribed in DC315 coating is limited to interior/exterior satin latex IBC Section 2603.4 and IRC Section R316.4 (2006 IRC Section R314.4). paint applied at an average wet film thickness of 8.0 mils (0.20 mm) or interior/exterior coating The DTM Bonding Primer, when used as part of the consisting of 30% silicon alkyd having a VOC (less assemblies listed in Table 1, must be installed in exempt solvents) of no more than 340 g/L (2.8 lb/gal) accordance with the manufacturer's published installation and a volume solids content of 62% applied at a instructions. maximum average wet film thickness of 8 mils (0.20 4.3 Application without a Prescriptive Ignition Barrier: mm). The use of either of the two interior finishes in conjunction with a vapor retardant coating is outside 4.3.1 General: Where spray-applied foam plastic the scope of this report. insulations listed in Tabe 2 are installed in attics and crawl 5.3 Recognition in this report is for the specific spaces without the ignition barrier prescribed in IBC assemblies and spray-applied foam plastic insulations Section 2603.4.1.6 and 2018, 2015, 2012 and 2009 IRC Sections R316.5.3 and R316.5.4 (2006 IRC Sections described in Tables 1 and 2. The spray-applied foam R314.5.3 and R314.5.4) the installation must be in plastic insulation must be installed in accordance with accordance with Sections 4.3.2 and 4.3.3, and the the requirements set forth in the specific ICC-ES following conditions apply: evaluation report noted. For spray-applied foam plastic insulation that is not covered in an ICC-ES a. Entry to the attic or crawl space is only to service evaluation report, the evaluation is limited as noted in utilities, and no storage is permitted. Tables 1 and 2, Footnote 3. b. There are no interconnected attic or crawl space 5.4 The coating is manufactured in Taoyuan, Taiwan and areas. Irvine, California, under a quality control program with c. Air in the attic or crawl space is not circulated to other inspections by ICC-ES. parts of the building. 6.0 EVIDENCE SUBMITTED d. Attic ventilation is provided when required by 2018 6.1 Data in accordance with the ICC-ES Acceptance IBC Section 1202.2 (2015, 2012, 2009 and 2006 IBC Criteria for Fire-Protective Coatings Applied to Spray- Section 1203.2) or IRC Section R806, except when applied Foam Plastic Insulation Installed without a air-impermeable insulation is permitted in unvented Code-prescribed Thermal Barrier (AC456), dated attics in accordance with the 2018 IBC Section 1202.3 October 2015(Editorially revised July 2018), including (2015 IBC Section 1203.3) or 2018, 2015 and 2012 room corner fire testing in accordance with NFPA IRC Section R806.5(2009 IRC Section R806.4). 286. e. Under-floor (crawl space) ventilation is provided when 6.2 Report of testing in accordance with ASTM E84 (UL required by 2018 IBC Section 1202.4 [2015 IBC 723). Section 1203.4 (2012, 2009 and 2006 IBC Section 1203.3)or IRC Section R408.1,as applicable. 6.3 Report of vapor permeance test in accordance with ASTM E96(Dessicant method). f. Combustion air is provided in accordance with IMC 6.4 Report of testing in accordance with Appendix X of (International Mechnical Code®)Section 701. AC377. 4.3.2 In attics and crawl spaces: In attics, the insulation 7.0 IDENTIFICATION may be spray-applied to the underside of roof sheathing or roof rafters, and/or vertical surfaces; and in crawl spaces, 7.1 All containers of DC315 coating must be labeled with the insulation may be spray-applied to the underside of the manufacturer's name (International Fireproof floors and/or vertical surfaces provided the assembly Technology Inc.) and address; the product name; the conforms to one of the assemblies described in Table 2. date of manufacture, the shelf life or expiration date; 4.3.3 Use on Attic Floors: The insulation may be the manufacturer's instructions for application, and installed between and over the joists in attic floor at the the evaluation report number(ESR 3702). maximum thickness set forth in Table 2. The insulation The spray-applied foam plastic insulations must be must be separated from the interior of the building by an labeled in accordance with the applicable evaluation approved thermal barrier. An ignition barrier prescribed in report(see Table 1). IBC Section 2603.4.1.6 and 2018, 2015, 2012 and 2009 7.2 The report holder's contact information is the IRC Sections R316.5.3 and R316.5.4 (2006 IRC Sections following: R314.5.3 and R314.5.4) may be omitted. 5.0 CONDITIONS OF USE INTERNATIONAL FIREPROOF TECHNOLOGY INC. 17528 VON KARMAN AVENUE The DC315 coating described in this report complies with, IRVINE, CALIFORNIA 92614 or is a suitable alternative to what is specified in, those (949)975-8588 codes listed in Section 1.0 of this report, subject to the www.painttoprotect.com following conditions: ptp@painttoprotect.com TABLE 1—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER(TESTED IN ACCORDANCE WITH NFPA 286) MAXIMUM DC315 COATING MINIMUM MAXIMUM MINIMUM THEORETICAL INSULATION INSULATION THICKNESS(in.) COMPANY NAME PRODUCT NAME THICKNESS(in.) (Overhead THICKNESS, APPLICATION (Vertical Surfaces) (Applied to all Foam RATE OF Surfaces) Surfaces) COATING2 Accella Polyurethane Bayseal CC X , 9 mils DFT Systems (ESR-2072) 51/2 91/2 14 mils WFT 0.88 gal/100 ft2 Accella Polyurethane Bayseal CC XP5,/2 9,/2 9 mils DFT 0.88 gal/100 ft2 Systems (ESR-2072) 14 mils WFT Accella Polyurethane Bayseal OC8,/2 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane Bayseal OC HY6,/2 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane Bayseal OCX9 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane EcoBay CC7,/4 71/4 12 mils DFT 1.13 gal/100 ft2 Systems (See Note 3) 18 mils WFT Accella Polyurethane Foamsulate 2108 12 13 mils DFT 1.25 gal/100 ft2 Systems (See Note 3) 20 mils WFT Accella Polyurethane Foamsulate 2205,/2 91/2 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane Foamsulate 506,/2 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane Foamsulate 50 N-IB 9 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane NatureSeal OCX 9 14 9 mils DFT 0.88 ga1/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane NeXGeN 2.0 12 mils DFT 8 10 1.13 gal/100 ft2 Systems (See Note 3) 18 mils WFT Accella Polyurethane QuadFoam®2.05,/2 91/2 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane QuadFoam®5008,/2 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane QuadFoam®500 OC $,/2 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane Sealtite CC+ 5,/2 91/2 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Accella Polyurethane Sealtite OC+ 8'/2 14 9 mils DFT 0.88 gal/100 ft2 Systems (See Note 3) 14 mils WFT Acme Urethanes WC 50 8 14 12 mils DFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT Barnhardt Manufacturing 12-008 9 mils DFT Company dba NCFI 8 14 0.88 gal/100 ft2 Polyurethanes (See Note 3) 14 mils WFT Barnhardt Manufacturing InsulBloc® , 9 mils DFT Company dba NCFI (ESR-1615) 51/2 91/2 14 mils WET 0.88 gal/100 ft2 Polyurethanes Barnhardt Manufacturing InsulStar® , 9 mils DFT Company dba NCFI (ESR-1615) 51/2 91/2 14 mils WET 0.88 gal/100 ft2 Polyurethanes Barnhardt Manufacturing Sealite OCX 12 mils DFT z Company dba NCFI (See Note 3) 10 14 18 mils WET 1.13 gal/100 ft Polyurethanes - , __ BASF Corporation ENERTITE®G 8'/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-3102) 14 mils WFT _ BASF Corporation ENERTITE®NM 81/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-3102) 14 mils WFT BASF Corporation SPRAYTITE 158 5,/2 9,/2 9 mils DFT 0.88 gal/100 ft2 (ESR-2642) 14 mils WFT BASF Corporation SPRAYTITE 178 5'/2 111/2 14 mils DFT 1.25 gal/100 ft2 (ESR-2642) 20 mils WFT BASF Corporation SPRAYTITE 81205 5,/2 9,/2 9 mils DFT 0.88 gal/100 ft2 (ESR-2642) 14 mils WFT BASF Corporation SPRAYTITE 81206 5'/2 111/2 14 mils DFT 1.25 gal/100 ft2 (ESR-2642) 20 mils WFT BASF Corporation SPRAYTITE SP 5,/2 9,/2 9 mils DFT 0.88 gal/100 ft2 (ESR-2642) 14 mils WFT BASF Corporation WALLTITE 200 5'/2 111/2 14 mils DFT 1.25 gal/100 ft2 (ESR-2642) 20 mils WFT BASF Corporation WALLTITE HP+ 5'/2 111/2 14 mils DFT 1.25 gal/100 ft2 (ESR-2642) 20 mils WFT BASF Corporation WALLTITE US 51/2 111/2 14 mils DFT 1.25 gal/100 ft2 (ESR-2642) 20 mils WFT MAXIMUM DC315 COATING MINIMUM INSULATION INSULATION MAXIMUM THICKNESS(in.) MINIMUM THEORETICAL COMPANY NAME PRODUCT NAME THICKNESS(in.) (Overhead THICKNESS APPLICATION (Vertical Surfaces) Surfaces) (Applied to all Foam RATE OF Surfaces) COATING2 BASF Corporation WALLTITE USN 51/2 11,/2 14 mils DFT 1.25 gal/100 ft2 (ESR-2642) 20 mils WFT Carlisle Spray Foam Foamsulate 508,/2 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam Foamsulate 50 HY8,/2 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam Foamsulate 708,/2 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam Foamsulate Closed Cell5,/2 9l/z 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam Foamsulate HFO5,/z 9'/2 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam Foamsulate OCX9 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam SealTite D7 Closed Cell7,/4 71/4 12 mils DFT 1.13 gal/100 ft2 Insulation (See Note 3) 18 mils WFT Carlisle Spray Foam SealTite D7 One Zero 9 mils DFT Insulation Closed Cell 51/2 91/2 14 mils WFT 0.88 gel/100 ft2 (See Note 3) Carlisle Spray Foam SealTite D7 Open Cell9 mils DFT ft2 Insulation (See Note 3) 8/z 14 14 mils WFT 0.88 gal/100 Carlisle Spray Foam SealTite PRO Closed 9 mils DFT Insulation Cell 51/2 91 /2 14 mils WFT 0.88 gal/100 ft2 (See Note 3) Carlisle Spray Foam SealTite PRO High Yield8,/2 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam SealTite PRO No Mix8,/2 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam SealTite PRO No Trim 218,/2 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam SealTite PRO OCX9 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT Carlisle Spray Foam SealTite PRO One Zero 9 mils DFT Insulation Closed Cell 51/2 9 h 14 mils WFT 0.88 gel/100 ft2 (See Note 3) Carlisle Spray Foam SealTite PRO Open Cell8,/2 14 9 mils DFT 0.88 gal/100 ft2 Insulation (See Note 3) 14 mils WFT CertainTeed Certaspray X OC 5'/, 14 13 mils DFT 1.25 gal/100 ft2 (See Note 3) 20 mils WFT Tiger Foam®E-84 Fire- Commercial Thermal Rated SPF Class 1 Spray3,/z 3,/z 13 mils DFT 1.25 gal/100 ft2 Solutions, Inc. Foam System 20 mils WFT (ESR-3183) Creative Polymer Solutions Air Lok 170 5'/2 9'/2 13 mils DFT 1.19 gal/100 ft2 (See Note 3) 19 mils WFT _ Creative Polymer Solutions Airl Lok 45 8 14 12 mils DFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT Touch N'Foam DAP Foam,Inc. Professional Class I FR 3,/2 31/2 13 mils DFT 1.25 gal/100 ft2 Spray Foam System 20 mils WFT (ESR-3758) Touch N'Seal Class I FR 13 mils DFT DAP Foam, Inc. Spray Foam System 31/2 31/2 20 mils WFT 1.25 gal/100 ft2 (ESR-3758) Demilec(USA)Inc. Agribalance® 71/2 11,/2 12 mils DET 1.13 gal/100 ft2 (ESR-2600) 18 mils WFT Demilec(USA)Inc. Demilec APX®2.0 51/4 14 13 mils DFT 1.25 gal/100 ft2 (ESR-3703) 20 mils WFT Demilec(USA)Inc. Demilec APX^' 8 10 13 mils DFT 1.25 gal/100 ft2 (ESR-3470) 20 mils WFT Demilec(USA)Inc. Demilec Heatlok®HFO 7'/2 111/2 9 mils DFT 0.88 gal/100 ft2 (ESR-4073) 14 mils WFT Demilec(USA)Inc. Demilec Heatlok®XT-s 71/2 11,/2 9 mils DFT 0.88 gal/100 ft2 (ESR-3824) 14 mils WFT Demilec(USA)Inc. Demilec Heatlok®XT-w 71/2 11,/2 12 mils DFT 1.13 gal/100 ft2 (ESR-3883) 18 mils WFT Demilec SEALECTION® 12 mils DFT Demilec(USA)Inc. 500 71/2 11 /2 18 mils WET 1.13 gal/100 ft2 (ESR-1172) _ Demilec(USA)Inc. HEATLOK SOY®200 PLUS 7,/2 111/2 12 mils DFT 1.13 al/100 ft2 (ESR-3210) 18 mils WFT g MAXIMUM DC315 COATING MINIMUM MAXIMUM MINIMUM THEORETICAL INSULATION INSULATION THICKNESS(in.) , COMPANY NAME PRODUCT NAME THICKNESS(in.) (Overhead THICKNESS APPLICATION (Vertical Surfaces) (Applied to all Foam RATE OF Surfaces) Surfaces) COATING Demilec(USA)Inc. Heatlok®Eco 51/2 91/2 14 mils DFT 1.38 gal/100 ft2 (ESR-3198) 22 mils WFT Demilec(USA)Inc. Sealection NM 71/2 111/2 12 mils DFT 1.13 gal/100 ft2 (ESR-2668) 18 mils WFT Elastochem Specialty Elastochem® 12 mils DFT z Chemicals, Inc. Insulthane®Extreme 71/4 71/4 18 mils WFT 1.13 gal/100 ft (ESR-3809) Elastochem Specialty Insulthane , , 9 mils DFT ft2 Chemicals,Inc. (See Note 3) 5/z 9/2 14 mils WFT 0.88 gal/100 EnergyOne America EOA 2000 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT EnergyOne America EOA 500 81/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-3686) 14 mils WFT Gaco Western F1850 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Gaco Western Gaco 183M 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Gaco Western GACO F1880 9 12 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Gaco Western Gaco Firestop2 F5001 18 18 12 mils DFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT Gaco Western Gaco Green 052N 111/4 111/4 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Gaco Western GacoEZSpray F4500 81/2 14 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT General Coatings Ultrathane 050 13 mils DFT ft2 Manufacturing Corp. (See Note 3) 8 10 20mils WFT 1.25 gal/100 DTM Bonding Primer 3 mils DFT/4 mils General Coatings Ultra-Thane 230 5,/2 71/2 WET 0.25 g /100 ft2 Manufacturing Corp. (ESR-3033) DC315 1.139 a1/100 ft2 12 mils DFT/18 mils WFT Guardian Energy Foam It Green , 13 mils DFT ft2 Technologies (See Note 3) 3/2 3/2 20mils WFT 1.25 gal/100 Henry Company Permax 1.8 11,/4 11,/4 14 mils DFT 1.31 gal/100 ft2 (See Note 3) 21 mils WFT Henry Company Permax 2.OX 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (ESR-3647) 14 mils WFT Henry Company Permax 2.OX Fast 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (ESR-3647) 14 mils WFT Huntsman International, CertaSpray CC51/2 9,/2 9 mils DFT 0.88 gal/100 ft2 LLC (ESR-3758) 14 mils WFT ICP Adhesives&Sealants, Handi-Foam E-84 Class 13 mils DFT z Inc. 1(A)Spray Foam System 31/2 31/2 20mils WFT 1.25 gal/100 ft (ESR-2717) Icynene, Inc. Classic 81/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-1826) 14 mils WFT Icynene, Inc. Classic Plus 8,/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-1826) 14 mils WFT Icynene,Inc. Classic Ultra 8,/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-1826) 14 mils WFT Icynene, Inc. Classic Ultra Select 8,/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-1826) 14 mils WFT Icynene,Inc. Icynene MD-C-200 6 10 14 mils DFT 1.38 gal/100 ft2 (ESR-3199) 22 mils WFT Icynene,Inc. Icynene ProSeal 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (ESR-3500) 14 mils WFT Icynene,Inc. Icynene ProSeal LE 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (ESR-3500) 14 mils WFT Icynene,Inc. ProSeal HFO 5/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Icynene,Inc. ProSeal Max HFC 6 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Icynene-LaPolla,Inc. Foam-Lok FL 450 8,/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-4242) 14 mils WFT Icynene-Lapolla,Inc. Prime Gold 81/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-4323) 14 mils WFT Johns Manville JM Corbond III 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT MAXIMUM DC315 COATING MINIMUM INSULATION INSULATION MAXIMUM MINIMUM THEORETICAL THICKNESS(in.) THICKNESS(in.) THICKNESS' APPLICATION COMPANY NAME PRODUCT NAME (Overhead (Vertical Surfaces) Surfaces) (Applied to all Foam RATE OF 2 Surfaces) COATING Johns Manville JM Corbond MCS'~ 71/4 91/4 14 mils DFT 1.38 gal/100 ft2 (ESR-3159) 22 mils WFT Johns Manville JM Corbond oc 71/2 111/2 12 mils DFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT Johns Manville JM Corbond ocx SPF 9 14 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Johns Manville JM MCS+ 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT LaPolla Industries,Inc. Foam-Lok FL2000 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (ESR-2629) 14 mils WFT LaPolla Industries,Inc. Foam-Lok FL500 81/2 14 9 mils DFT 0.88 gal/100 ft2 (ESR-2847) 14 mils WFT LaPolla Industries,Inc. Lapolla FL 2000 4G 51/2 91/2 9 mils DET 0.88 gal/100 ft2 (See Note 3) 14 mils WFT LaPolla Industries,Inc. Lapolla Foam-Lok FL 750 81/2 14 9 mils DET 0.88 gal/100 ft2 (ESR-4322) 14 mils WFT Natural Polymers,LLC Natural-Therm-0.5 IB 91/2 14/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Natural Polymers,LLC Natural-Therm-0.50 PCF 91/2 14/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Natural Polymers,LLC Natural-Therm-2.0 IBS 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Natural Polymers,LLC Natural-Therm-2.0 IBW 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Natural Polymers,LLC Natural-Therm~Light 91/2 141/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Natural Polymers,LLC Natural-Therm."ZERO 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Nu-Wool Company Nu-Seal 0.59,/2 14,/2 9 mils DFT 0.88 gal/100 ft2 Incorporated (See Note 3) 14 mils WFT Nu-Wool Company Nu-Seal 2.0 W51/2 14 9 mils DFT 0.88 gal/100 ft2 Incorporated (See Note 3) 14 mils WFT Polygreen Solutions GreenSeal 44 8 14 12 mils DFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT Preferred Solutions,Inc. Staycell0 302 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Profoam ProSeal 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (ESR-3835) 14 mils WFT Purinova Sp.Z.O.O. Purinova PURIOS 500 8 14 12 mils DFT 1.13 gal/100 ft2 (ESR-4165) 18 mils WFT RHH Foam Systems Versi-Foam Class I 31/2 31/2 13 mils DFT 1.25 gal/100 ft2 (See Note 3) 20 mils WFT Rhino Linings Corporation ThermalGuard CC2 51/2 91/2 9 mils DET 0.88 gal/100 ft2 (ESR-2100) 14 mils WFT Rhino Linings Corporation ThermalGuard OC.5 71/2 11,/2 13 mils DFT 1.13 gal/100 ft2 (ESR-2100) 18 mils WFT SES Foam Nexseal 2.0 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT SES Foam Nexseal 2.0 LE 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT SES Foam SES 2.0 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT SES Foam SES 2.0 LE 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT SES Foam SES Foam 0.5 lb 81/2 14 9 mils DET 0.88 gal/100 ft2 (ESR-3375) 14 mils WFT SES Foam Sucraseal~0.5 9 14 9 mils DFT 0.88 gal/100 ft2 (ESR-3375) 14 mils WFT Specialty Prodcuts,Inc. Envelo-Seal•~0.5 OC9,/2 141/2 9 mils DFT 0.88 gal/100 ft2 (S.P.I) (See Note 3) 14 mils WFT Specialty Prodcuts,Inc. Envelo-Seal•~2.0 IBW 5/2 14 9 mils DFT 0.88 gal/100 ft2 (S.P.I) (See Note 3) 14 mils WFT Sustainable Polymer 0.5 OC81/2 14 9 mils DFT 0.88 gal/100 ft2 Products (See Note 3) 14 mils WFT Sustainable Polymer 0.5 OCX9 14 9 mils DFT 0.88 gal/100 ft2 Products (See Note 3) 14 mils WFT Sustainable Polymer 2.0 CC51/2 91/2 9 mils DFT 0.88 gal/100 ft2 Products (See Note 3) 14 mils WFT SWD Urethane Quik-Shield 100X 7 11 12 mils DFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT MAXIMUM DC315 COATING MINIMUM MAXIMUM MINIMUM THEORETICAL INSULATION INSULATION THICKNESS(in.) , COMPANY NAME PRODUCT NAME THICKNESS(in.) (Overhead THICKNESS APPLICATION (Vertical Surfaces) (Applied to all Foam RATE OF Surfaces) Surfaces) COATING2 SWD Urethane Quik Shield 104 8 14 12 mils OFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT SWD Urethane Quik-Shield 106 111/4 111/4 15 mils OFT 1.50 gal/100 ft2 (See Note 3) 24 mils WFT SWD Urethane Quik-Shield 108 81/2 14 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT SWD Urethane Quik-Shield 112 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT The Dow Chemical FROTH-PAKTh131/2 31/2 14 mils DFT 1.25 gal/100 ft2 Company (ESR-3228) 20 mils WFT STYROFOAM TM Spray The Dow Chemical Polyurethane Foam91/2 91/2 15 mils DFT 1.38 gal/100 ft2 Company CM2045 22 mils WFT (ESR-2670) The Spray Market SPM-200 71/2 111/2 9 mils DFT 0.88 gal/100 ft2 (ESR-4195) 14 mils WFT Thermoseal 2000 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Thermoseal Thermoseal CCX 71/2 111/2 9 mils DFT 0.88 gal/100 ft2 (ESR-4137) 14 mils WFT Thermoseal TS 5G 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Thermoseal TS One 51/2 91/2 13 mils DFT 1.25 gal/100 ft2 (See Note 3) 20 mils WFT Thermoseal TS360 81/2 14 13 mils DFT 1.25 gal/100 ft2 (See Note 3) 20 mils WFT Thermoseal TS500 12 mils DFT 8 14 1.13 gal/100 ft2 (See Note 3) 18 mils WFT Thermoseal TS800 8 14 12 mils DFT 1.13 gal/100 ft2 (See Note 3) 18 mils WFT Universal Polymers UPC 50081/2 14 12 mils DFT 1.13 gal/100 ft2 Corporation (ESR-3803) 18 mils WFT Urethane Technology UTC 7040-0.551/2 143/4 14 mils DFT 1.25 gal/100 ft2 Company, Inc. (ESR-3244) 20 mils WFT Urethane Technology UTC 7041-0.551/2 143/4 14 mils DFT 1.25 gal/100 ft2 Company,Inc. (ESR-3244) 20 mils WFT Volatile Free, Inc. VFI-714 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT Volatile Free,Inc. VFI-716 81/2 14 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT XtremeSeal,LLC XtremeSeal 0.4 LX 81/2 14 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT XtremeSeal,LLC XtremeSeal 0.5 LX 81/2 14 9 mils DET 0.88 gal/100 ft2 (See Note 3) 14 mils WFT XtremeSeal,LLC XtremeSeal 2.0 LE 51/2 91/2 9 mils DFT 0.88 gal/100 ft2 (See Note 3) 14 mils WFT For SI: 1 inch=25.4 mm;1 mil=0.0254 mm; 1 gallon=3.38 L;1 ft2=0.93 m2. Notes: 1DFT=Dry Film Thickness;WFT=Wet Film Thickness 2As reported in the manufacturer's application instructions. Actual application rate, based upon specific project conditions, must be in accordance with the manufacturer's application instructions. 3Recognition is limited to the NFPA 286 test data for the coated assembly described.Evaluation for compliance of the spray foam insulation with other applicable requirements of AC377 and the IBC and IRC are outside the scope of the report. TABLE 2-USE OF INSULATION WITHOUT A PRESCRIPTIVE IGNITION BARRIER (TESTED IN ACCORDANCE WITH APPENDIX X OF AC377) MAXIMUM DC315 COATING MINIMUM MAXIMUM THICKNESS(in.) MINIMUM THEORETICAL INSULATION INSULATION THICKNESS(in.) (Underside of Roof ' APPLICATION THICKNESS'COMPANY NAME PRODUCT NAME (Vertical Surfaces Sheathing and/or THICK(ApplieN toallRATE OF and Attic Floors) Rafters,Underside Foam Surfaces) COATING2 of Floors) Accella Polyurethane Bayseal OC , 1 3 mils DFT Systems (See Note 3) 9/2 111/2 4 mils WFT 0.25 gal/100 ft2 Accella Polyurethane Foamsulate 50 12 12 3 mils DFT 0.25 gal/100 ft2 Systems (See Note 3) 4 mils WFT Accella Polyurethane Foamsulate 50 HY91/z 11'/2 3 mils DFT 0.25 gal/100 ft2 Systems (See Note 3) 4 mils WFT Accella Polyurethane QuadFoam®50091/z 11'/2 3 mils DFT 0.25 gal/100 ft2 Systems (See Note 3) 4 mils WFT Accella Polyurethane Sealtite OC+ 14 14 3 mils DFT 0.25 ga1/100 ft2 Systems (See Note 3) 4 mils WFT Acme Urethanes WC-50 8 14 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT BASF Corporation ENERTITE®G 111/2 151/2 3 mils DET 0.25 gal/100 ft2 (ESR-3102) 4 mils WFT BASF Corporation ENERTITE®NM 111/2 151/2 3 mils DFT 0.25 gal/100 ft2 (ESR-3102) 4 mils WFT BASF Corporation SPRAYTITE 158 51/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT BASF Corporation SPRAYTITE 178 51/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT BASF Corporation SPRAYTITE 81205 51/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT BASF Corporation SPRAYTITE 81206 51/2 11 /2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT BASF Corporation SPRAYTITE SP 51/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT _ BASF Corporation WALLTITE HP+ 51/2 11 /2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT BASF Corporation WALLTITE US 51/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT BASF Corporation WALLTITE US-N 51/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2642) 4 mils WFT Carlisle Spray Foam Foamsulate 50 12 12 3 mils DFT 0.25 gal/100 ft2 Insulation (See Note 3) 4 mils WFT Carlisle Spray Foam Foamsulate 70 14 14 3 mils DFT 0.25 gal/100 ft2 Insulation (See Note 3) 4 mils WFT Carlisle Spray Foam SealTite PRO No Mix 12 12 3 mils DFT 0.25 gal/100 ft2 Insulation (See Note 3) 4 mils WFT Carlisle Spray Foam SealTite PRO No Trim 21 14 14 3 mils DFT 0.25 gal/100 ft2 Insulation (See Note 3) 4 mils WFT Creative Polymer Solutions Air Lok 170 51/2 91/2 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Creative Polymer Solutions Airl Lok 45 8 14 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Demilec(USA)Inc. Agribalance® 71/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2600) 4 mils WFT Demilec SEALECTION® Demilec(USA)Inc. 500 71/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-1172) 4 mils WFT Demilec(USA)Inc. Heatlok®Eco 111/2 111/2 3 mils DFT 0.25 gal/100 ft2 (ESR-3198) 4 mils WFT Gaco Western Gaco Green 052N 111/, 111/, 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Gaco Western GacoEZSpray F4500 12 16 3 mils DFT 0.25 ga1/100 ft2 (See Note 3) 4 mils WFT General Coatings Ultrathane 050 6 8 3 mils DFT 0.25 gal/100 ft2 Manufacturing Corp. (See Note 3) 4 mils WFT General Coatings Ultra-Thane 23071/2 111/2 3 mils DFT 0.25 gal/100 ft2 Manufacturing Corp. (ESR-3033) 4 mils WFT Icynene,Inc. Classic 51/2 14 3 mils DFT 0.25 gal/100 ft2 (ESR-1826) 4 mils WFT Icynene, Inc. Classic Plus 8 14 3 mils DFT 0.25 gal/100 ft2 (ESR-1826) 4 mils WFT Icynene,Inc. Classic Ultra 51/2 14 3 mils DFT 0.25 gal/100 ft2 (ESR-1826) 4 mils WFT Icynene, Inc. I Classic Ultra Select I 51/2 I 14 I 3 mils DFT I 0.25 gal/100 ft2 MAXIMUM DC315 COATING MINIMUM MAXIMUM THICKNESS(in.) MINIMUM THEORETICAL INSULATION INSULATION THICKNESS(in.) (Underside of Roof , COMPANY NAME PRODUCT NAME (Vertical Surfaces Sheathing and/or THICKNESS APPLICATION and Attic Floors) Rafters,Underside (Applied to all RATE OFZ of Floors) Foam Surfaces) COATING (ESR-1826) 4 mils WFT Icynene, Inc. Icynene MD-C-200 8 14 3 mils DFT 0.25 gal/100 ft2 (ESR-3199) 4 mils WFT Icynene,Inc. Icynene ProSeal 8 14 3 mils DFT 0.25 gal/100 ft2 (ESR-3500) 4 mils WFT Icynene,Inc. Icynene ProSeal LE 8 14 3 mils DFT 0.25 gal/100 ft2 (ESR-3500) 4 mils WFT Icynene-LaPolla,Inc. Foam-Lok FL 450 5'/2 14 3 mils DFT 0.25 gal/100 ft2 (ESR-4242) 4 mils WFT Icynene-LaPolla,Inc. Prime Gold 5'/2 14 3 mils DFT 0.25 gal/100 ft2 (ESR-4323) 4 mils WFT Johns Manville JM Corbond III 7'/2 91/2 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Johns Manville JM MCS+ 7/2 9,/2 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT LaPolla Industries, Inc. Foam-Lok FL500 5'/2 11,/2 3 mils DFT 0.25 gal/100 ft2 (ESR-2847) 4 mils WFT Natural Polymers,LLC Natural-Therm" HFO 7,/2 11,/2 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Natural Polymers,LLC Natural-Therm"' ZERO 71/2 11,/2 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Polygreen Solutions GreenSeal 44 8 14 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Purinova Sp.z.o.o. Purinova PURIOS 500 8 14 3 mils DFT 0.25 gal/100 ft2 (ESR-4165) 4 mils WFT Rhino Linings Corporation ThermalGuard OC.5 8 12 3 mils DFT 0.25 gal/100 ft2 (ESR-2100) 4 mils WFT Rhino Linings Corporation ThermalGuard 1.0 8 12 3 mils DFT 0.25 ga1/100 ft2 (See Note 3) 4 mils WFT SES Foam SES Foam 0.5 lb 9'/2 11,/2 3 mils DFT 0.25 gal/100 ft2 (ESR-3375) 4 mils WFT Sustainable Polymer 0.5 OC HY9,/2 111/2 3 mils DFT 0.25 gal/100 ft2 Products (See Note 3) 4 mils WFT SWD Urethane Quik-Shield 108 8 12 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT Universal Polymers UPC 5008,/2 14 4 mils DFT 0.38 gal/100 ft2 Corporation (ESR-3803) 6 mils WFT Urethane Technology UTC 7040-0.55,/2 143/4 3 mils DFT 0.25 gal/100 ft2 Company, Inc. (ESR-3244) 4 mils WFT Urethane Technology UTC 7041-0.551/2 143/4 3 mils DFT 0.25 gal/100 ft2 Company, Inc. (ESR-3244) 4 mils WFT XtremeSeal,LLC XtremeSeal 0.4 LX 8 12 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT XtremeSeal,LLC XtremeSeal 0.5 LX 9'/2 11,/2 3 mils DFT 0.25 gal/100 ft2 (See Note 3) 4 mils WFT For SI: 1 inch=25.4 mm; 1 mil=0.0254 mm;1 gallon=3.38 L;1 ft2=0.93 m2. Notes: 'DFT=Dry Film Thickness;WFT=Wet Film Thickness 2As reported in the manufacturer's application instructions. Actual application rate, based upon specific project conditions, must be in accordance with the manufacturer's application instructions. 3Recognition is limited to the NFPA 286 test data for the coated assembly described.Evaluation for compliance of the spray foam insulation with other applicable requirements of AC377 and the IBC and IRC are outside the scope of the report.