Loading...
1411 HIBISCUS ST - ROW20-0005 RIGHT OF WAY PERMIT PERMIT NUMBER Jqr Y" ROW20-0005 a _ CITY OF ATLANTIC BEACH o'r ISSUED: 2/13/2020 800 SEMINOLE ROAD ATLANTIC BEACH. FL 32233 EXPIRES: 5/13/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1411 HIBISCUS ST RIGHT OF WAY SINGLE OR TWO COMCAST- 140' COAX & 2 $0,00 FAMILY RIGHT OF WAY BORES TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: I GROUP: 171072 0000 ATLANTIC BEACH SEC H COMPANY: ADDRESS: CITY: STATE: ZIP: COMCAST5934 RICHARD ST JACKSONVILLE FL 32216 COMMUNICATIONS OWNER: ADDRESS: CITY: STATE: ZIP: 1411 HIBISCUS ST LLC 399 BEACH AVE ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. Issued Date: 2/13/2020 1 of 2 i''''r<r RIGHT OF WAY PERMIT PERMIT NUMBER s CITY OF ATLANTIC BEACH ROW20-0005 ,� v 800 SEMINOLE ROAD ISSUED: 2/13/2020 �rn �? ATLANTIC BEACH. FL 32233 EXPIRES: 5/13/2020 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 4 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. S PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date:2/13/2020 2 of 2 w� rwr� ri�;irJ City of Atlantic Beach ��i V t APPLICATION NUMBER '� Building Department FEB (To be assigned by the Building Department.) 800 Seminole Road D 0 s ��- /�C • 2 Atlantic Beach, Florida 32233-54 (fib li3 �U Phone(904)247-5826 • Fax(904 -5845 / ' oIi 0 E-mail: building-dept@coab.us Date routed: Z Cc? LC) City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 4 1 ,----A l r�( S GU s,.. -(- Department review required Yes No `.� Building Applicant: d (�/��. Ptd T Planning &Zoning Tree Administrator Project: 14 0 �« � C Z Boe ssgu,glic���n-_rs==> �ublic U iliti Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Other Agency Review or Permit Required of Permit Verified By Date Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [/pproved. I IDenied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b Dater--/2.„40 TREE ADMIN. Second Review: I Approved as revised. I 'Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I 'Approved as revised. Denied. Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach APPLICATION NUMBER .i r •a Building Department (To be assigned by the Building Department.) 800 Seminole Road O L/3 hC Atlantic Beach, Florida 32233-5445 l�J Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: Z (0 tE0 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM c. Property Address: ( 4 1. SCO c7 ( Department review required Yes No Building Applicant: L-LO (1/\C INS T Planning &Zoning /� 2 Tree Administrator • Project: 14 0 Cc)f-w- Z Bce eu' . '' 'ublic Utiliti- Public Safety Fire Services Review fee $ 26" °� Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI TION STATUS Reviewing Department First Review: I Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: � c. e: 2-0 —7.a TREE ADMIN. Second Review: ❑Approved as revised. nDenied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I /Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 1-,.; RIGHT-OF-WAY/EASEMENT PERMIT 141 CSW Z Permit#Issued by the City of Atlantic Beach O 0 O C) 3 PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 1411 HIBISCUS ST, ATLANTIC BEACH, FL Phone 405-314-9079 Permittee AFG/COMCAST Email SANDERS@FIBERCOREGROUP.COM Requesting Permission to Construct PROPOSED UG CATV FACILITIES 140' COAX, 2 BORES Location(Reference to Cross-Street)W 14TH ST, VIOLET ST • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,` — both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient op ton, alteration or relocation of all,or any portion of said street or easement as determined by the DirectUPf Pubia020 Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed '_ under the supervision of (Project Superintendent) with Company Name Phone • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again i edia el pon completion. Date 02-/C/7-'0 Zfl Pet rhittee(si ed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVALF The f re oing instrument knowledged this 1 day of �\ U ,20 ), by %ha& \ �� ,who pe rally appeared before me and printed name of Pe 'tt )acknot he/she signed '• trument voluntaril for the purpose expressed in it. _ Personally Known ,/�) Signature of Notary Publi State o Flo ` a _ ihA�red Identification(Type) Q/4 .��rn "'• MALLORY DAVIS "•� Notary Public State of Florida •! Commission N GG 301923 " My Comm.Expires Feb 14,2023 PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: 2 10 -- Z Application#: �(,t] 20 - goes- Project QQsProject Address: 1 '4 ( \b\ s-cos l Check Box Check APPLICATION TRACKING COMMENTS to Add Box to Comment Print Underground Avoid damage to underground water and sewer utilities. Verify vertical and Water Sewer horizontal location of utilities. Hand dig if necessary. If field coordination is Utilities needed, call 247-5878. Meter Boxes Ensure all meter boxes, sewer cleanouts and valve covers are set to grade Sewer 0 0 Cleanout and visible. A sewer cleanout must be installed at the property line. Cleanout must be RT1 Sewer covered with an RT1 concrete box with metal lid. Cleanout to be set to grade ❑ 0 Cleanout and visible. A reduced pressure zone backflow preventer must be installed if irrigation will RPZ Backflow be provided or if there is a private well on the property. Backflow preventer ❑ ❑ must be tested by a certified tester and a copy of the results sent to Public Utilities. Plans note the building will be unsprinkled. If plans change, any fire line Sensus installed must be metered with a Sensus touch-read meter in a properly sized Touch-Read vault and an appropriate backflow preventer installed. Backflow preventer 0 0 Meter must be tested by a certified tester and a copy of the results sent to Public Utilities. Fire Sprinkler If fire sprinkler system is provided, call 247-5878 for backflow requirements. Requirement Backlow At a minimum,will require a double check backflow preventer. 0 0 Fire Line Fire lines must be metered with a Sensus touch-read meter. Meters larger ❑ ❑ Meter than 2" must be installed in a vault as noted in JEA specifications. Utility Map See attached Utility Map. Disconnect &Cap Disconnect and cap water and sewer lines. 0 0 Inspection MUST call the Inspection Line at 247-5814 to request an inspection of the Prior disconnected and capped water and sewer lines PRIOR to demolition. ❑ ❑ Utility All water & sewer utility connections must be inspected prior to cover up. Inspections Please call the inspection line at 247-5814 to schedule inspections 24 hours in 0 ❑ advance. System All fees must be paid for water&sewer connections before meters will be set. Development Please call the finance department customer service line 247-5816 to 0 0 Fees coordinate payment of fees. 0 0 r ,.g n 9 �e RD �f �4 .'� r "a w5 ;w i v, ON N. I • V ' Itittit ,3 . . . , ..,,,,...... , ,.. .. . ...criiiiiiitatit. ; , . ,. , .. .i 1 a; 1 1 1 t '4006 ,t.� 70 : w J r-. ws,. .01,'-`- 1 '-' rir 1" r,i I,1,,,v• • :, A 43 $ '`� :. v y PV FT9l P�'J l r3"; A .'' b`'r1 i ',,,:::;,...:4`,..;,!:.7(.14?'.;,',; I �i�.C'k`k!1i- s 14TH ST W n $ .F . , " M -�.i=:7SJ S 1•A3-LLi-t�_.�-'='t".Z=_:i::IC _ -rt"f-fE'�-1.-1. ..Z:_r t7- - -=-L=-�:Z L _:� IC_114 1__ - 1.11,41 0 1. at } y Lip i so ''.,,.•.,,, 13 f{ u ' v. t' ,.., a 342 '"1, si j 6 F COMCAST PERMIT REQUEST FOR 1411 HIBISCUS ST,ATLANTIC BEACH, FL 32233 HOLMES COUNTY BANTA COUNTY JACKSON ROSA COUNTY COUNTY OKALOO'S1 COUNTY W,1LTp1 WASHNOTON THESE PLANS WERE PREPARED UNDER THE COUNTY ICVLEON .,....zsimiti RESPONSIBLE CHARGE OF COMCAST AND BAY ARE EXEMPT FROM THE SIGNING AND SEALING COUNTY LA WWAKUL -TAYLOR REQUIREMENTS PRESCRIBED IN DUES SECTION 471 OF THE FLORIDA STATUTES COUNTY FRANKLIN caNrr i!irlii MUNI"' niFIACIL, COUNTY C o� 2 °D PRY v .TrD 9 NYRYirNY B��I.INWERK. r MANNA" ... O ATM SoILt'"Ttrosolhalm"'"''S v "" .�0 t 4 IN..... ,. COUNTY Levy Rd lnvestrr_. „MEN.01..,.., r .r.., CITRUS COUNTY RARERCOUNTY n... RARER COUNTY Generation ♦ .r.. * 'PEA"NO°Selr � igeration Co.,Inc 9 �'�'q pOiAb 19,,, ,,,,,..... "'.... "" COWRY PASCO F P t • AIN tl� .n.A.r.� COUNTY • 1 t ' i `.iw11Mp�9 C PUl! 06CE°U. .S' BREVARD �.._ .---_-, ti mob....IN COUNTY COUNTY COUNTY :1 W14th Si Y .,.A INDIAN RIVER O. ! •. M .."1.....A>y 1 COURY �.F_'..T,r C i B[0 MANNIEE NAMES UNEECHKUEE . .L ii _... •••,,. + COUNTY COUNTY BAHT • LUCE - - + 4 9 NIONLANOS COUNTY Ovalti WAVY 9.WO,.S OEBOTO COUNTY - E O ..'" OU 9-. SARASOTA CORNY MARTIN1J . + MACES • , CHARLOTTE COUNTY COUNTY VICINITY MAP mon 1411 HIBISCUS ST,ATLANTIC BEACH,FL 32233 c°um couHry Rose C01 # 9 JOB NUMBER: 105000262738 RI^' BOIEW 1 PROJECT TOTALS cw.ty ° r° c°unr PROPOSED AERIAL FOOTAGE 0• PROPOSED AERIAL RISER FOOTAGE 25 .HONES JOB SITE: PROPOSED UG CATV/FIBER 140' COW,' a cowYDE 1411 HIBISCUS ST, TOTAL FOOTAGE 165' ATLANTIC_BEACH,FL 32233 TOTAL PROPOSED BORES 2 i 1 TOTAL PROPOSED BORE PITS 1 N CO St © POLE ©A"�T PROPOSED UG CATV!FIBER CITY OF ATLANTIC BEACH STREET GNT –SA—SIL— PROPOSEp AERUL—A----.--A-- X woo USAGE POLE Y PEDESTAL FACILITIES IN DUVAL COUNTY,FLORIDA W E �tR —E—E— PROPOSED TRENCH• X WOOD POLE ❑PEpEBTAL RIGHT-OF-WAY VICEDTY VEw CRA: ATLANTIC BEA. PERMIT .ILA1 -- — PROPOSED BOREB—OS—DR— ® TRANSE°RINER POLE )=( ptAERT 5934 RICHARD ST WATER —WATER GAS —,.c—‘,' O RISER POLE SHEET NO 1 OFD COUNT, RENAL JACKSONVILLE,FLORIDA 3221E1 SLS —SEWER RENT OP WAY ••— •• KXI'KE SORE PR N Harr°xue STATE ROMAUR — — — s _ O DATE: 02.01-1020 DRAW FRIER CORE ORO, NOTES ALL PROPOSED CONSTRUCTION WILL BE PER ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY THE CITY OF ATLANTIC BEACH SPECIFICATIONS AS WILL BE RESTORED TO ORIGINAL OR BETTER ALL UTILITIES LOCATED BY WELL AS ALL NECESSARY SAFETY CODES. CONDITION BY GRADING AND RE-SODDING.SOD ALL VISUAL INSPECTION,TO BE VERIFIED BY LOCATES AREAS DISTURBED BY CONSTRUCTION WITH ALL PROPOSED CATV WILL BE WITHIN THE CITY OF BERMUDA SOD."ALL CRACKED SIDEWALK IS TO BE EOT REPRESENTS EDGE OF ATLANTIC BEACH RIGHT-OF-WAY. REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF TRAVEL NOT TRUE EDGE OF WORK COMPLETION." PAVEMENT ALL PROPOSED UNDERGROUND CATV WILL BE E/P REPRESENTS THE TRUE BURIED A MINIMUM OF 36"DEEP EXCEPT ROAD BORES WORK OPERATIONS ARE TO BE MINDFUL NOT TO EDGE OF PAVEMENT 60"DEEP AND DRIVEWAY BORES AT 60"DEEP. DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EOD REPRESENTS THE EDGE EQUIPMENT.ANY DAMAGE INCLUDING TRACK MARKS OF DIRT ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL BE REPAIRED OR REPLACED BY THE HAND DIG TRENCHES 36"DEEP WILL USE CITY APPROVED DIRECTIONAL BORE CONTRACTOR. ACROSS DIRT ROAD MACHINE,AS WELL AS COUNTY APPROVED CONDUIT. CONSTRUCTION NOTES ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 11'BEYOND THE EDGE OF PAVEMENT. IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND THE RIGHT-OF-WAY AND EASEMENTS.THE A MINIMUM OF 11'BEYOND THE EDGE OF PAVEMENT. PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK ALL PROPOSED BORES WILL BE IN A(4'X4'X4')PIT THROUGH FIELD VERIFICATION OF THE AND WILL USE(2)2"HDPE CONDUIT AT 48"DEPTH LOCATION OF THE EXISTING UTILITIES IN USING A 5 1/4"DRILL HEAD. CASE OF OPEN EXCAVATION.VERIFICATION MAY BE PERFORMED DURING THE ALL PROPOSED AERIAL WILL BE.700"DIAMETER AND PERMITTEES WORK.IN THE CASE OF WILL BE LASHED TO.250"STEEL STRAND CABLE DIRECTIONAL DRILLING,VERIFICATION SHALL USING.125"STANDARD GALVANIZED LASHING WIRE. TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT. ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0" THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS AVOID CONTACT WITH DETECTION WILL HAVE MINIMUM MID-SPAN HEIGHT OF 16'-0" EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL RIGHT OF WAY -•---•�-------- LOCATES WILL BE REQUIRED IN ALL PROPOSED NOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT SED AERIAL —A UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO AND GROUND PENETRATION RADAR(GPR). PROPOSED TRENCH CONSTRUCTION. THE EXCAVATOR SHALL BE HELD LIABLE FOR BURIED POWER DAMAGES CAUSED TO CITY'S/COUNTIES/ An, ART - NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE STATE INFRASTRURE AND THE EXISTING FACILITIES OF THE OTHER UTILITY STORM SEWER - sR R- ER- MADE PRIOR TO CONSTRUCTION. WATER —WRIER_WAhR_ COMPANIES FENCE CO �� —_.. c0 CONCRETE POLE p YAULT PROPOSED AERIAL b UG CAN/FIBER M CC CITY OF ATLANTIC BEACH a aEE• icHT L—E—E— PROPosEO AERI,u—A- -A �( JOINT USAGE POLE Y ANCHOR FACILITIES IN DUVAL COUNTY,FLORIDA W �� E RIGHTOFWAY E—E—E— PROPOSED - x WOOD POE ❑PEOEBT yas,Ruc o""o.Ea cov .LAWnc.E"cH PERMIT PROPOSED BORE —Be—De—Be— ® TRANSFORMER POLE CULVERT SHEET No: 2 0, DOLS, owr,L 5934 RICHARD ST WATER —WATER— GAS RR ® RISER POLE Nor To SGLE BTATE: FLORIDA S JACKSONVILLE,FLORIDA 32216 SEWER —SEWER— RIGHT OF WAY —A-- 0 AXEDA'BORE PR GATE SEWW.vam EUWN: FIBER coRE ORouP I i ! 1411 HIBISCUS ST, I I :. I ..� , ATLANTIC BEACH, FL 32233 W •;�;. E 400 i ,~ I 1 OF 1 I 1-1 ! s I ii I ! 11 I II. IL� ! 248Dl a a I 490 w w I blb I sr '15' '20' 15' I 1411 1 , 15'' .M END PROJECT h I 248 ' w w ' PROPOSED UG a $ Z5 I z I CAN/FIBER FACILITIES % r w LL PROPOSED 0 511 1 COMCAST VAULT 9'EOP w i, STA:01+E0 BORE PIT 4'X4'%4' brc I GPS COORDINATES POWER RISERIO'EOPI ' ( ) i 1 I' N 30.335008 RUNLINE 8'EOP , JI e W-81.419772 WATER T EOP -- i' 01+00__100' iir ) • I ..—.---- - ---- .--. — • r —R/W r Vi Olw ow �� °^^ EOP 10'LANE « WL14TH ST L— 40' —a _ —� 10'LANE ---- •-----•— //�-- - ----�RIW-------7 ® . F..—.. ..-------� I JI, �1 I 3=10 I 1390 480 I BEGIN PROJECT ,15' 20'! 15' ' PROPOSED UG , 1 290 I JI, I CAN/FIBER FACILITIES ' ' 1 282 STA:00+00 , GPS COORDINATES Z w , 111 "IZ N 30.334699 5 D IW-81.419375 I -,e ';'-. 0. , ?IIb I L `I I 11 y I 1386 JJJJ,„ ID 34.9 , 1285 N I I ,o5I 1369 m j 1 n : r IjU 1270 ; I I £ g 1225 1336 1334 1 i 111II N © CONCRETE POLE g VAULT PROPOSED AERIAL&UG CAN/FIBER CO MCC !ll/�y/1'3� CITY OF ATLANTIC BEACH S1REET DONT —S.- -0.- r'Ra'OS O AeRiu—a - X ,OIs,VBWE POLE ‘11F w+ONOR FACILITIES IN DUVAL COUNTY,FLORIDA W ® E Illi III ILllll�J.� RIGHT OF-WAY `+`" —F—E—E— PRorosEO rRENCN.— X WOOD POE P®EsrAL�y MT AllANT� „C„ PERMIT PRoroSEDBORE —Oe—Oe—OB— ® TRANSFgiMERPOLE = OULvcN, 5934 RICHARD ST WA-Eli —WATER OAS o RISER POLE weer. 3OFR COMM DA'. BCALE'. NOT TO PL'YE RATE: FLORIDAS JACKSONVILLE,FLORIDA 32216 SEWER —SEWER— MONT OP WAY —• -- 0 AM..BORE PIT BATE: O,M-]0!0 OAAWN: PIM COM BROM I 1 1411 HIBISCUS ST,ATLANTIC BEACH, FL 32233 & CROSS SECTION _ 50' L 25' —I 25' 15' J I 15' ..- 0 -10' —I— 10' II 1 011 0" — • • 24" { < 36" < 36"— < 48" I 48"- 60" I 8. _ 60"— 1 W W W W wi CC g 0 o: O. N © CONCRETE POLE [2 BAJA./ PROPOSED AERIALS UG CAN/FIBER COl!11 �e+ CITY OF ATLANTIC BEACH sTREE*JON. sAi—sA—ea— cRocosEo o s-—a-- ^ ^ )( JOINT Ua oe POLE Y MC/LORAL FACILITES IN DUVAL COUNTY,FLORIDA W ® E \\`!� ILII ILII Illi • I lw RIGHT-OF-WAY =owEH —E—E—E— aROPoseD TRENCH—�—� X WOOD POLE ❑PeOPST L mews WWTwn Erre. ATLANTIC REACH PERMIT FIBER PRowaSE0BORE —DB--MP—DB— ® TRANSFORMER POLE = CUBE,.i 5934 RICHARD ST WATER —WATER— OBE ® RISER POLE SCFE*Ca .oFe TATE sum NOT TO WALE TRATE PLOf11M S JACKSONVILLE,FLORIDA 32216 SEWED —SEWER— wog OPwAv --- 0 ♦....BORE PIT DATEmmaco duvet: FIBER CORW E CRO 3 1411 HIBISCUS ST,ATLANTIC BEACH, FL 32233 0 DIRECTIONAL ROAD BORE DETAIL FOR W 14TH ST 50' — - 25' — 25' 15' I 15' U 10, - 10' .- ENTRY I RECEIVE BORE BORE PIT . 40._ (4'X4'X4') SFE ►t4►0'4►4►4►4►4►����f•�������f•�����1♦4►4►4►���4►4►��•4►4►����4►�4►•'►�4►�4 0" 24" I� 24.F 60'DEPTH 36" ,0 36"--48"60n SI,,. (2)-2"HDPE CONDUIj W/5 1/4"DRILL HEAD /1"1 8" _ //, lV lV lV l/•7l,\Zl7\Z1\Z !V/\/ ",/Ir CJO" I a. cc I m m N , _.. _.._. PHONE __.. © CONCRETE POLE M VAULT PROPOSED AERIAL 8 UG CATV/FIBER COWil (1(11 St CITY OF ATLANTIC BEACH STREET LIGHT —SE—&L—BSL— PROPOSED AERIAL—A--A— x JOINT USAGE POLE Y ANCHOR FACILITIES IN DUVAL COUNTY,FLORIDA W ® E ILII TUI ILII RIGHT-OF-WAY PS HE—E—E— PROPOSEDTRENCH—�—�u _ �( WOOD POLE ❑PEDESTAL A CNV: *IAN*IL'AC."PERMIT FIBER PROPOSED BORE —OS�OS.—OB— ® TRANSFORMER POLE �j CULVERT MEET NO SOF! COUNTY. DIWAL 5934 RICHARD ST WA ER —WATER— GAS ® RISER POLE SCALE NOT To SCALE STATE: FLORIDA S JACKSONVILLE,FLORIDA 32216 SEWER —SEWER-- ROHE OF WAY —^----•— 0 <x%,BORE PIT SETS 0.14020 DRAWN: PEER CORE GROUP ROAD WORK END AHEAD i ROAD WORK I 4G; A a a b + U • 1 LP A B rAVEn LENGTH.UR \\\%/////WORK AREA/ ' SEE TAKE x //�//////// END ' ROAD ROADWORK, WORK �// — DEVICE SPA...TAPER DEVICE SPACWbTANGENT 60D• AHEAD SEE TABLE I SEE TAKE I SPEEDING FINES MISLED TABLE 1I PBFaENT Taper Length-Shoulder 1/3L(R) Table I ae1l - NOM (mvhl r 17 17 Device Spacing SNd SIP& Shia. e•x.Distance Eldrhwen Dem.(ft) Type l or Type II 25' 22 35. 17 Speed Cones or DISTANCE BETWEEN SIGNS aapta Tubular Markers or Weibel 37 40 50' t0 Lei Panels or33' 56' 6r 97 SPACED(FT.1 speed Tiler I TnpvTaper TaTangent NY 77 Yr 107 A B 10 Gon or less 200 200 25 20 50 23 S0 b' 110 167 167 IS i,we 350 360 3002 es 25 so so to 57 132 107 207 50 MO or gwAs' 600 500 505070 25 50 60 100 66' 147 tar 227 •250 beyond the ROAD WORK MEAD sIgn or Medway 60' 160' 207 0'21L WS between signs whichever A Ina 85' 173 217 200 70' lar 233' 260' r IW,s,,ahoutder wdh. GENERAL NOTES DURATION NOTES ll,2,kwgmNMoulder 1pernrue SYMBOLS 1 Signs and chenneliz,ng deuces may be omitted if all of the V//A Work Ares 1.When lour or mom work vechicles enter the through traffic lanes in a one hour following conditions am met: w.width°Hotel Moosbrn pet period or less(excluding establishing and terminating the work arae),the advanced . Work operations am 60 minutes or less. (oomovOp•vse end unpaved ) FLAGGER sign shell be substituted for the WORKERS signfor location of loggers b. Vehicles(1 the work area have high-Intensity, • Chem,00zmg Device(see Index 102-600) and FLAGGER signs,see index no 102-603. rotating. flashing,oscillating,or strobe lights •a Posted speed set(mM) nD., 2.SHOULDER work sign may be used es an alternate to the WORKER symbol sign only °�mting ty Work Zone Sign on the side ethers the shoulder work G being performed, �2 lade Identllkltbn ii,Direction of Trem/k 3 When a side road intersects the highway within the TTC eons,additional TTC CONDITIONS devices shell be placed in accordance with other application TC2 indexes. 4.For general TC2 requirements end additional information,refer to Index 102-600 WHERE ANY VEHICLE.EQUIPMENT.WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER THAN 15'BUT NOT CLOSER THAN TO THE EDGE OF TRAVEL WAY. DESCRIPTION: LAST FY 2019-20 INDEX SHEET REVISION TWO—LANE,TWO—WAY, WORK ON SHOULDER 011/01/17 STANDARD PLANS 102-602 6of 8 © 0 ROAD WORK AHEAD • SLAP SPACER I C B A ., a a a 4— j ■ q- D _ D •_I woRrc A - © 5p ROAD A B C I svncER 0 60P WO AHEARKD ROAD ESP I-EN V © TO-LANE, O-WAY I SPAt.E I C B A WORK WTW AHEAD a a a a41. 4) a 77////// AK_ _BUFFER SPACE TOP. AREA a a a Speed Dist. D D D (mote) f21 //�� 25 155 rtrr Qcry me 3o zoo pN�145575 35 zoo A D B D C I BUFFER SPACE 40 305 45 360 50 425 OAD 55 4es AHWORK D © MULTILANE 80 570 65 645 DISTANCE BETWEEN SIGNS GENERAL NOTES Speed 5p00050 071 1. This Index does not apply to limited access realities. (mphl A 'B c SYMBOLS 40501555 200 200 200 2. When a side road Intersects the highway within the TTC zone.additional BC devices 45 350 350 350 shall be pieced in accordance with applicable TCZ Indexes. 50 or Greeter 500 500 500 3. Traffic volume or complexity of the roadway may dictate additional devices,signs. ® W... flagmen and/or a traffic control officer. 4. The buffer space may be omitted if there are no sight obstructions to vehicles 01 —/—svo approaching the Flegger/Om'cer for distance equal to the bullar space. 1J 00000 5. A Flogger may be substituted fora traffic control officer and the BE PREPARED TO STOP sign may be * hem Coowom� omitted,fitted,when the following conditions are met: a.Speed limit is 45 mph or less /50e n...eo0.00,/5.000r rr.mr b.No sight obstructions to vehicles approaching the Flogger/Officer fore distance equal to the buffer space. CONDITIONS C.vehicles In the work area have hgh-ntenseay,mating,hashing.oscillating,or strobe PLANNED CLOSURE NOT lights operating. EXCEEDING 5 ANNUTES 6. On undivided highways the median 540 as shown are to be omitted, 7 For general TCZ requirements and additional Information refer to Index 002-600 DESCRIPTION: ' LAST FY 2019-20 INDEX SHEET REVISION "D STANDARD PLANS TEMPORARY ROAD CLOSURE 5 MINUTES OR LESS 7OF8 � • • 102-625 THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION 2019-2020 102-600 INDEX AND APPLY TO 1411 HIBISCUS ST, ATLANTIC BEACH, FL 32233 • STANDARD PLANS INDEX NO 102-602 (TWO-LANE, TWO-WAY, WORK ON SHOULDER) • STANDARD PLANS INDEX NO 102-625 (TEMPORARY ROAD CLOSURE 5 MINUTES OR LESS)) N �0[ LJ Ll CO:S © CONCRETE POLE y ANCHNAM,OR PROPOSED AERIAL&CO CAN/FIBER CITY OF ATLANTIC BEACH SIRGI T LIcwT —st—%2—sA— PROPOSED AERIAL—'--A—'� X JOINT USAGE POLE Y Arw,�oR FACILITIES IN DUVAL COUNTY,FLORIDA W E RIGHT-OF-WAY ::,r. —E—E—E— PROPOSED TRENCH- - X WOOD POLE 0POUT.TRAFFIC CONTROL RULESST GTV. ATLANTIC BEACH PERMIT PROPOSED BORE —DB—A•DS—I`R— ® TRANSFORMER POLE JJ CULVERT BMEET NO BDG. COUNTY. 5934 RICHARD ST WATER —WA MR OAF —PM 0 RISER POLE SCALE NOTFLORIDATO.GA.E STATE s JACKSONVILLE,FLORIDA 32216 SEWER —SEWER- RIORT OF WAV -----'-- 0 .so.BORE PIT DATE, 02:01DRAWN: AWN CORE GROW