Loading...
1853 Beach Ave RES20-0032 Garage Door 11Up.rj, RESIDENTIAL PERMIT PERMIT NUMBER vi CITY OF ATLANTIC BEACH RES20-0032 800 SEMINOLE ROAD ISSUED: 2/13/2020 \'�`J;11yr EXPIRES: 8/11/2020 ATLANTIC BEACH, FL 32233 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1853 BEACH AVE RESIDENTIAL GARAGE DOOR $3500.00 WINDOWS/DOORS TYPE OF I REAL ESTATE 1BUILDING USE I ZONING: i SUBDIVISION: CONSTRUCTION: NUMBER: I GROUP: 169723 1110 THE NAUTILUS CONDOMINIUM COMPANY: ADDRESS: CITY: STATE: ZIP: OVERHEAD DOOR CO. OF 6884 N PHILIPS PARKWAY DR JACKSONVILLE FL 32256 JAX OWNER: ADDRESS: CITY: , STATE: ZIP: KONOPASEK JAMES L 1853 BEACH AVE ATLANTIC BEACH FL 32233-5938 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS I Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT 1 BUILDING PERMIT 455-0000-322-1000 0 $70.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $35.00 I STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.28 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.85 Issued Date:2/13/2020 1 of 2 Yt �,'?i, RESIDENTIAL PERMIT PERMIT NUMBER s. CITY OF ATLANTIC BEACH RES20-0032 800 SEMINOLE ROAD ISSUED: 2/13/2020 �';��� ATLANTIC BEACH. FL 32233 EXPIRES: 8/11/2020 WORK WITHOUT PERMIT 455-0000-322-1000 0 $180.00 TOTAL:$292.13 Issued Date:2/13/2020 2 of 2 ;'1, City of Atlantic Beach APPLICATION NUMBER Building Department (To be assi ned by the Building Department.) -� `i 800 Seminole Road � ` �^� 'yam r', Atlantic Beach, Florida 32233-5445 t \ ESZO_ 003 Phone(904)247-5826 • Fax(904)247-5845 -�� 11 �r E-mail: building-dept@coab.us Date routed: Z fr) // z. CD City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: t -553 l? cAc 4Des • • 'lent review required Yes No :uildinq Applicant: U�f EAQ DQO(Z -lanning &Zoning Tree Administrator Project: �� Pt`ACj C-- D002_, Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: I l4proved. r Denied. Not applicable (Circle one.) Comments: roc Q ,b,i �' -Pee- odve S (,•43 C BUILDIN C' t PLANNING &ZONING Reviewed by: 1 ' l Date:2////2 a 20 TREE ADMIN. Second Review: I lApproved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. I INot applicable Comments: Reviewed by: Date: Revised 05/19/2017 rS`-kBuilding Permit Application OFFICE COPY Updated 10/9/18 City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY ▪ ini19', IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us j� 7 Job Address: / .5I D ( ucJ4 �(1�t Permit Number: 1\ ---,s Z_� _ 00 3z. Legal Description P.J 4z. 4 2-49421/4.5- t( RE# fGq 72-3-I/(D Valuation of Work(Replacement Cost)$ 3 3 O0 Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New ❑Addition ❑Alteration Elr<pair ❑Move ODemo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial PR(sidential • If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No • Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) 14+ 0 Describe in detail the type of work to be performed: Orrocipe rgy1_I"l rcp`4_e H1.- joor„s Florida Product Approval #I FL 7‘42..4?Y for multiple products use product approval form Property Owner Information Name I ."', O I1Q pt„S 4 Address (S�3 L au • City 'o kA,4L1 r State M. Zip 22233 Phone E-Mail j KO vi0 Q yA O� 1M Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) -.- .r- Contractor Information CI4 1 i/C W Npi Name of Company otos‘ trC Odor`6O. T C Qualifying ent 1►IG/WJaV 1 0 t Address fty fitfitlp, f*Wk Of. µj. City Sax Q State lY• Zip Z22a Cl) Office Phone ff Dy'g4V-IGS.') Job Site Contact Number (1f 7 - (O a J T Q Z State Certification/Registration# E-Mail R.14. e p f t Icor . Cah 0 Z 2 Architect Name& Phone# c W O CI Engineer's Name&Phone# 0 00p o Q Workers Compensation Insurer S�A`IL /(lGO'A y �P , OR Exempt❑ Expiration Date q-!G.'lV cl U C � Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installeioqqz 0 commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regiOr�,ti O� Q construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING SIL�I� N1.1).WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE: In addition to the requirerr e Ah w permit,there may be additional restrictions applicable to this property that may be found in the public records of this cqa , ix W there may be additional permits required from other governmental entities such as water management districts,state ageigne ,om federal agencies. Ww 5 a Wo iiiOWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance wiMMla�_ N Q applicable laws regulating construction and zoning. W j WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT M4' °C RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE REC0f2DING;YOUR NOTICE OF COMMENCEMENT. ig jail , - 11:________( ol-0->rflx ' ' (Signature of Owner or Agent) (Signature of Contractor) r . Si d sw n o(. affirm: before r thi/ day of ' ed and sworn to(or a fir -•)be ore me his .g d.y of re K , .y i � . •.,_• - �/ _ by �� I4!.* / I f ` N, Noaycery i2 ,„�) ;.� .*,. TONI GINS ESI ;;gatIfof ack) MYCOMMISSIPL; 353178 Vw g Ero0m1sio2n 292750 "" •'•;,moi, EXPIRES:October 6,2023 'ersonally K . [ 1•afkJnat3gngecbTAno ficibbry Public Underwriters [ ]Produced Identification ••000 -. o- • • �3 / /� Type of Identification: Type of Identification: W G93 0 ` 75-8 - 690c- ! 2 -C NOTICE OF COMMENCEMENT State of F(6(. Tax Folio No. _ County of To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated/i'n tljis NOTICE OF COMMENCEMENT. Legal Description of property being improved: B/pc 72 2_ - 9.0Cos— Address of property being improved: UJ_3 13e&di (/C. C( Pa Ge4ct e/h- 322 3? General description of improvements: n e(,0 fOOr 1 badr fur 6&rrl e.- Owner: N((. 44, 1143 CohJo A sOG, Address: (D s� IJ�o`�L a'UG Owner's interest in site of the improvement: Fee Simple Titleholder(if other than owner): Name: /q p I'_ Contractor: v tier It calO ue Ca. 7-aG kfah V��l lkG • / Address: ' / ()Wig Potr(Cc..1G l D,;1G IVJna C ccob(/i'(1 f(4. 3 2 2 (o Telephone No.: '0 Y a(ps (G l 7 Fax No: q0 7 o. c( Surety(if any) y� Address: Amount of Bond$ Telephone No: Fax No: .-- Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: nK0 ko 7 s,0 /46,-1 /� - Address: (�5 ca cL GCu[ ii 9icC cif • 4-176)-G � 1•j Telephone No: 17Gp'1.is() Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) Name: L>�� Address: Telephone No: � Fax No: C) Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER ff Signed: Date: ' ) J �G Before me this Cy23. dayof F-2 Cu.C'- ` a0 Jin the Countyof Duval,State Doc#2020034887,OR BK 19103 Page 1922, b —*- Number *- Of FI rida s personally appeared 3p n1.2— —�`• Number Pa es: 1 P JENNIFERJOHNSTON 9 Notary Public at Large,State of Flo( a,Count : ` :_ Recorded 02/13/2020 10:15 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL My commission expires: R�! • MY COMMISSION#GG 042984 • w EXPIRES.Outuber 27,2020 COUNTY Personally Known: •.:{ie-I1n9eQiGriters RECORDING $10.00 Produced Identification: FL. DLt`i�9a`,S t s.! " OFFICE COPY Rick Ward From: Jim Konopasek <jlkono@yahoo.com> Sent: Tuesday, February 4, 2020 6:43 AM To: Rick Ward Subject: Re: door installation 1853 beach avenue Atlantic beach Rick, You may need the following info: "Nautilus Condominium Association of Atlantic Beach" 4 permanent resident Units 1851, 1853, 1855, 1857 Although this is a Florida condominium, what most inspectors are not aware of is that a condo with 4 or less residents is exempt from many of the condo codes exclusive to condos with more than 4 residents. Do all garage doors require a permit,or just condos. We might be exempt. We are replacing the door roll down portion with exact same. What might also play into this is, the garage is"common area" with no communication access to any of the dwellings. There are three accesses to the garage: 1) the front west roll down 2)the rear east double French doors 3) the south open to the weather stairway with no means for closure Your guys were told by the inspector(Rick Bell) that he was putting a stop work tag on my front door. No such notice was placed nor was I contacted. Jim Konopasek 904-476-6550 On Monday, February 3, 2020, 3:28 PM, Rick Ward <rick@ohdjax.com>wrote: PICKING UP A PERMIT TOMORROW From:Jim Konopasek<jlkono@yahoo.com> Sent: Monday, February 3, 2020 2:32 PM To: Rick Ward <rick@ohdjax.com> Subject: Re: door installation 1853 beach avenue Atlantic beach hi Rick, I just by chance ran into your guys as I was coming home. I didn't find any notice tag left from the inspector. Please keep me posted,thanks. Jim Konopasek 1 OFFICE COPY The Genuine. The Original. ' ' DO k_ e, oss ---- wslt. Installation Instructions for ROLLING SERVICE DOOR Model 610 Stormtite Models 620,625 _ =- Stormtite"' AP Model 627—_ This installation manual provides the owner or service person �� ! information required to install,troubleshoot and maintain a Rolling ���� Service Door. -- 'i Contents Warnings&Safety Information 2 _� Key Drawing 3 � Door Installation Data Sheet 4 Pre-Installation Checks&Tasks 5 = Installation 6-12 — –____ Warranty 13 READ COMPLETE INSTRUCTIONS BEFORE INSTALLING DOORS. This document also refers to the following other documents or specifications; Expansion Anchor Requirements 307390 Installation Instructions,Cast Gear Drive Chain Hoist 308042 Chain Hoist Assemblies and Operation 300951 Horizontally spliced hood installation tips PIB 10403 300922-0011 Rev M 10/05/2016 www.overheaddoor.com 02016 Overhead Door Corporation Key Drawing Rolling Service Door with parts. Right hand door is illustrated. In a left hand door the barrel and both brackets are reversed. Guides for masonry jambs shown. Interior Hood Support Barrel When Required Tension End Assembly Drive End Bracket Bracket Tension / Hood Wheel Drive Sprocket IV \t, I / V ? ), 1 P, .,;,,i ii,,,J --7-4'----=. . • , . ‘t,.-. . , ____, N. V ,.. _ �l _- DRIVE END TENSION ENCS _ . �. Warning Decals k.,..__ `` 5 feet from floor Angle Guide Assembly Shown — Curtain Assembly . t', a . Bottom Bar --"A 1' `r- h ;0 Please note that components and component locations are shown here for REFERENCE ONLY. Your unit installation and component locations may be different. 3 300922-0011 Rev M 10/05/2016 www.overheaddoor.com ©2016 Overhead Door Corporation • . STEP 2 LINTEL INSTALLATION • If lintel baffle is required,install baffle using 1/4"fasteners suitable for the wall material(wood,masonry,steel). Install per Figure 9 with brush aligned 1"above top of guide middle angle. STEP 3 HEADER J IDENTIFY HEADPLATE BRACKETS Right Hand Drive shown;Left Hand Drive is opposite. See Figure 10. STEP 4 Fig 9 GEAR DRIVE HEADPLATE: JAMB NOTE:Install gear hoist mounting bolts in headplate ATTHIS TIME;see Overhead Door instructions 308042. STEP 5 IDENTIFY BARREL ASSEMBLY DRIVE END Right hand drive shown in Figure 11;left hand drive is opposite. HEADPLATE BRACKET Look for an"R"for right hand drive or an"L"for left hand drive stamped on the end of TENSION END DRIVE END the drive shaft. BRACKET BRACKET SPRING CONFIGURATION—See Figure 12. WELDED Ns ON . • Left hand drive configuration has end of spring pinned to barrel near tension end. STOP IDENTIFIED • Right hand drive counterbalance has end of spring pinned to barrel several feet 0 I BY BOLTED-IN from tension end. ouTSIDE �� BEARING INSIDE • At tension end of barrel the bearing assembly may be pinned to the barrel as Fig 10 shown in Figure 12,or the bearing assembly may be welded into end of barrel. BARREL ASSEMBLY A WARNING TENSION END DRIVE END BEARING WELD Counterbalance damage could allow curtain to close rapidly which could , 1111*— 1� KEYWAY result in death or serious injury.To avoid counter balance damage,the drive �� -� v' FIg 11 headplate must be usedwith the drive shaft of the barrel assembly. r IV ROTATING SHAFT RIGID DRIVE SHAFT WITH PINHOLE OR KEYWAY TOWARDS CENTER — TENSION OF PIPE DRIVE SHAFT SHAFT 0 RIGHT HAND DRIVE 0 0 3/8"PINS SEVERAL DRIVE j INCHES SHAFT TENSION SHAFT LEFT HAND DRIVE 0 ° Fig 12 3/8"PINS 7 300922-0011 Rev M 10/05/2016 www.overheaddoor.com ©2016 Overhead Door Corporation STEP 9 INSTALLATION OF CURTAIN See Figure 15 ROPE �, ...1 • The Sling Method is recommended because rolling the curtain onto the barrel assembly on the floor can cause rr✓�r� ' curtain damage. _ -�Jam'' '-10.1°.*' r iso. • Sling Method requires flared guide angles to be removed at this time. \ ;.. • Suspend the curtain below the barrel on two or more slings or ropes rated for the weight of the curtain shown -� ; .►�1 Iia • .-4 on the"Installation Data"sheet. . �1. a y� '`1f.1 Fasten the top slat to sling/rope and rotate the barrel to bring the Top Slat into place. - • Center the curtain between the headplate brackets with pinned tension wheel against the headplate. r ``A� • If the barrel has rings,hold the top slat on the rings and make holes in the top slat aligned with holes in rings. Use drill/driver to attach top slat to rings with 3/8"round head Torx screws and washers provided. Set the drill/ -- , Fig 15 driver clutch to minimum torque required to drive screws. DO NOT USE IMPACT WRENCH because it will strip 5/16"flat washer the screw threads in rings. See Figure 17. sns x u2"long-_ c, • If the barrel has studs,the top slat will have slots to attach to barrel. Hook curtain over studs and fasten with round head screw /Y�/ p ,=, Two clam 5/16"round head screws and washers and TWO clamp washers provided. See Figure 16. r washers required Weld stud �� ''V—= J l ‘` },f\ 4/ Fig 16 \ 9 A WARNING Curtain to ring Rapidly closing curtain could result in death or serious injury. Use slings/ropes and locking pliers on both salt-tap 3/8"X 5/8bolt, Torx T45 drive guides to keep curtain in the open position until spring tension is applied to the barrel assembly. ai6°Flat Washer STEP 10 - •-1._ COMPLETE CURTAIN INSTALLATION 1r • Coil curtain completely onto barrel. /' max. max • If guides are flared,then bolt middle and outside angles to the wall angles as shown in Fig 5 on page 5. The guide gap must be set as shown in Fig 6 on page 5.Find the GUIDE GAP dimension on the"DOOR Fig 7 INSTALLATION DATA"sheet,see Fig 2 on page 4. • Place locking pliers on LH&RH guides at 2 to 3 inches below the top of the guides as shown in Fig 18. • Create enough slack in the sling/rope so the curtain can be lowered into the guides and rest on thett _ locking pliers. - 4 I i iiiNg'. III) � I r ‘,N Guide Locking Pliers Fig 18 9 300922-0011 Rev M 10/05/2016 www.overheaddoor.corn ©2016 Overhead Door Corporation f OFFICE COPY 8 I I 6I 5I 4 D NOTES I 3 I 12.THE SPECIFICATIONS FOR THE BOLT USED FOR THE ®PENSIONS 1. DESIGNED AND TESTED IN ACCORDANCE WITH FLORIDA BLDG CODE AND INTERNATIONAL BLDG CODE. Z-GUIDE TO ATTACH THE GUIDE TO THE CONCRETE JAMB 13.CHART OF WIND LOCH CLEARANCE °A'� �' pp // // PROFESSIONAL ENGINEER'S SEAL PROVIDED ONLY FOR VERIFICATION OF WIND LOAD ARE FOR POWERS R BOLT(P/N 607692-XXX%. MAX OPENING WIDTH CLEARANCE TENSILE 32084/3 H 00101 J REVISE SE PEA ER 1)aOJIp 145, CONSTRUCTION DETAILS. THE HILTI QUICK BOLT P/N 608983-X%XX)MAY BE 2.SPACING IS THE CENTER TO CENTER DIMENSION. SUBSTITUTED TO ACHI EQUIVALENT WINDLOAD RATING BY W< _ 15' 0.625 w0x1 X REVISE PER EA J.INDICATES SLAT FREQUENCY IN WHICH WINDLOCKS OCCUR. USING THE FOLLOWING S POWERUTION CHART AND THE SAME UP TO 20' 4.DELETED. SPACING AS THE POWERS BOLT. 0.875 `\ \\\\, NUS /i ' 5.WALL ANGLES MAY BE WELDED TO STEEL JAMBS.PLUG WELDS N THE WALL ANGLE UP TO 40' 1.875 \\\\\,A 8.8 POWERS POWER BOLT MILLI KWIK BOLT J Y�4'f"- SLOTS THE THICKNESS OF THE ANGLE OR FILLET WELD AT THE HEEL AND TOE OF THE WALL ANGLE (3000 CONCRETE) (3000 PSI CONCRETE) UP TO 40. 1.875 ' D 2 LONG AT EACH SPECIFIED BOLT LOCATION.TO HOLD 1HE LOADS LISTED IN THE GUIDE TABLE. DIAMETER EMBED DIAMETER EMBED • N0.e1737 \. 6.•E•GUIDE DOORS HAVE THREE WALL FASTENER LENGTHS,THEY ARE: D 3/8"DN(GRADE 2)= 1•LONG WALL BOLT 3/8' 2 3/e" 2-1/2• * ' 3/8 DA(GRADE 5) - 1-1/z LONG WALL BOLT 3/8• 2-1/Y 3/e• 2-1/2• -qq7'AJJ a OF 1/2 DN_ 1-I/z•LONG WALL BOLT 1/2" 2-1/2" l/2" 2-3/4• :�•.!"tpq CA'''W r" � 8.ASTM A-36,GUIDE ANGLE MATERIAL. I/2• J• 1/2• 3-1/2" ��77j��JJq A` 0... 9. DOORS AT 5'-9•WIDE WILL HAVE NO WINOBAR. 1/2• S" 1/2• 5• 77j71111111\\ 5/e• 4• s/e• ♦• 10.REFERENCE F-265 SLAT DRAWING 307210 11. DOOR OPENINGS 18'-e AND LESS USE SLATS 22 Go JOHN E.SCATES PE DOOR OPENINGS DYER 18'-4•USE SLATS 20 Go 3121 FAIRGIE —' CARROLLTON.TETRAS 75007 MOMENT "E"—GUIDE "Z"—GUIDE FL PE/51737 k I WH FL # 742-R4 - WH .I I• + E MH---{ I E Digitalysigned byJohn E.ScatesP.E. WT 1.11.1..191 �_ I J 1 Date:2017.0928135909 0500' rr y WT� I iii _ Swv r_ �_ C PARALLEL ' 1 MV WV 1. •� FORNORCE l M�l- I OV t MT OV —rt } +- 1 NORMAL SECTION "0-0" i i"X I T Z� x-- G /...A) FORCE E AND Z GUIDES SHOWN +If__ -OMH +I Zr-OT •A' •0) T ..11_,._ J TENSION T �OH--� �'----OH—� WHEEL I _ E—GUIDE Z—GUIDE NOTES MEAOPUTE I WIND PRESSURE WIND PRESSURE --I UIDE DOOR OPENING WIDTH 5'-9• 10'-9• 15' 20' 25' 30' 35' 40' 9'-3" 15' 20' 25' 30' 35' 40' B I • WALLHORIZONTAL WN 2-1/2 3 3-1)2 3-1/2 4 4 4 4 2-1/2 3-1)2 3-1/2 4 4 5 5 WALL VERTICAL WV 3 3 2- 2 3 3 3 3 3 3 2- 2 3 3 3 3 3 8 WALL THICKNESS wT 3/18 3/16 1 5/16 3/8 3/(8 1/2 1/2 3/18 1 5/16 3/8 3//8 1/2 1//2 (SEECHAAIRNT•A' I I 30`0• MMIDDLE HVERTICAL AN 2 2-2/2 3 2 2-1/2 2-1/2 2-1/2 2-1/2 2 2/2 3 2 2-1/2 2-1/2 2-1/2 2-1/2 MAX.DOOR •• HEIGHT OUTSIDE® OH© 2-1/2 3 3-1/2 3-1/2 4 4 4 4 OUTSIDE VERTICAL CV J 4 4 4 4 4 4 4 3-1/24 J-4/2 4 4 4 44 OUTSIDE THICKNESS OT 3/18 1/4 1/4 1/4 1/4 1/4 5/16 5/16 1/4 1/4 1/4 1/4 1/4 1/16 5/4 18 v����� I E E i-354 2-1 4 2-1 4 2-1 4 2-1/2 2-1(2 2-1/2 2-1/2 1-I.(2 2-1/2 2-3/4 3-1 4 3-1 4 4-1/4 4-1/4 -g• .B. 5 5 2-1 4 1-5 8 1-13 18 1-13 16 1-7/13 1-7 B 2 2 1-5(8 1-13 16 1-13/16 1- 8 1-7 B 2 2 V V 15 18 1-3 18 1-1 4 1-1 4 1-S 16 1-5 ]6 1-3/8 1-3/8 1-31/16 I-1 1-1 16 1-3 8 1-3/6 O G 2-1 4 2-3 4 2-13 18 Z-118 2-�6 2-7/8 3 3 2-3 4 2-13 18 2-13 18 2-7,8 2- 8 3 3 BABOTTOM SECTION "A—A" X X NONE 1-1 8 1-1 4 ' 1-1 2 1-7 8 1-77yB 2-]B 2-3 8 1-1 8 1-1 4 1-1 2 1-7 8 1-7 8 2-3 8 2-3 8 WEAIHERSRTIP Z Z NONE 15 16 15 18 15 16 15 16 15 18 15 16 1S`/18 15 16 15 16 15 16 15 16 15 16 15 16 15 16 40'0• WALL BOLT SIZE 3/8 3 8 1 2 1 2 1/2 132 1 2 1/g 3 6 1 2 1 2 1 2 5 8 5 5 MAX DOOR OPENING WIDTH WALL BOLT GRADE 2 2 2 5 5 5 5 5 NA NA NA NA NA NA NA 8 WALL BOLT EMBED N/A N/A N/A N/A N/A N/A N/A N/A 2-1 2• 3 3 5 4• 4• WALL BOLT SPACING 1 36 1e 1e 18 16 14 12 10 18 II e is 8 B 7 22 ASSEMBLY BOLT SIZE 3/B 3/B 1/2 1/2 1/2 1/2 5/8 5/8 3/8 1/2 1/2 1/2 1/2 5/8 5/8 ASSEMBLY BOLT GRADE 2 2 5 5 5 5 5 5 2 5 3.16 ASSEMBLY BOLT SPACING 38 18 18 18 13 105 5 I 5 I5 A tee WINDLOCK FREQUENCY 0 10 9 1e 10 17 15 11 12 11 2 C MOMENT 2 2 2 2 2 2 1 2 2 2 2 2 2 1 3 274 1637 ' 4193 8173 7549 9979 12309, 14912 1131 4126 6080 7380 9776 11994 14552 A _ NORMAL 102 168 270 360 450 540 6.30 720 167 270 360 450 540 630 720 2 5/8" CA ���� PARALLEL _ 0 386 1033 1514 1767 2412 2612 3244 250 1033 1514 7787 2412 2642 3244 1.78 2.74 i i THE ORAR'RIOS NC ALL OTHER WFORINACN CONTAINED HERON ARE THE CONFDD/IIAL ANC PROPRIETARY PROPERTY OF 0I161CM DOORUARPORATON 000 ITS AFFILIATED COMPANIES. TH6 DRAWINGA O INFORIMIION,RI WHOLE OR IN PART.WY ROI BE COPIED IN ANY MANNER OR DISCLOSED 10 ANYONE 111X0,11 THE PRIOR ARDEN CONSENT Of MIO01U•D DOOR DORPOPATXRL NO DISCLOSURE OF i NO Of THIS ORATING OR INfORMARU•I IS ICING(U TO OPERATE AS A UCUISE 011 NRIOWZAI ON TO USE IT FOR NO PURPOSE WNW At SPECIFIC WRITTEN mow OF MAIM DOOR CORPORA110N. 933 I 1 N/) 1O HOLE FINISH WINDLOAD, s/e• �� WHOLE NUMBERS: 0.25 'IR •T• ...... % t .1 N/A • N.WOLji 11/19/02 e10/811/620J621,F-265. SLAT DETAIL F-265 ALT. WINDLOCK DETAIL `""m"°" OX *'03 UNIT OF ""�" +38/-38 PSF(DESIGN) .XXX !.010 MEASURE N/A JD FAR 1/24/03 "'m., ANGLES: * •s' A�D—308094 8 I I 6 I 5 I REF DWG USED ORES: !Z N/A I 2 DM WpLS 1/24/03 100 N/A 1 1• 1 7 1J I 2560 King Arthur Blvd Ste 124-54 Lewisville TX 75056 John E. Scates, Professional Engineer office (972)492-9500 September 28, 2017 Overhead Door Corp. 2501 S State Hwy 121 Bus, Suite 200 Lewisville, TX 75067 Re: Series 610, 620, 625 rolling doors FL 742 To Whom It May Concern: To the best of my knowledge, the products listed in FL 742 conform to the requirements of the 6th Edition (2017) of the Florida Building Code. As requested by Overhead Door Corporation, I have confirmed the wind load door designs shown on the drawings listed below. I have reviewed the independent tests by Architectural Testing Inc., the rational engineering analysis, and the product drawings. I have concluded that the door designs are in compliance with the 6th Edition (2017) Florida Building Code. This evaluation was built upon a foundation of 22 actual door tests that were used to validate the engineering calculation methods at various known points. Using these calculation methods, the door configurations listed on the drawings were then designed within the allowable limits established by the actual door tests. Static pressure tests were conducted in accordance with ASTM E-330-2002 and ANSI/DASMA 108-2002 (and 108-2012). Impact testing was conducted in accordance with TAS 201-94 and TAS 203-94. Specific sizes and limits are as shown on the drawings. I certify that I meet the requirements of "independence" as detailed in Florida Statutes, as it relates to Overhead Door Corporation. FL 742 Drawings Static Pressure products: 308082 Rev.J Windload, Series 610/611, C187 slat. Limitations: 26 psf Design, Maximum door width 20', Maximum door height 30' 308083 Rev. J Windload, Series 610/611, C187 slat. Limitations: 31 psf Design, Maximum door width 20', Maximum door height 30' 308084 Rev.J Windload,Series 610/611, C187 slat. Limitations: 36 psf Design, Maximum door width 20', Maximum door height 30' 308085 Rev. J Windload, Series 610/611, C187 slat. Limitations: 41 psf Design, Maximum door width 20', Maximum door height 30' 308086 Rev.J Windload, Series 610/611, C187 slat. Limitations: 50 psf Design, Maximum door width 20', Maximum door height 30' 308087 Rev. J Windload, Series 610/611, C275 slat. Limitations: 26 psf Design, Maximum door width 40', Maximum door height 30' 308088 Rev. J Windload, Series 610/611, C275 slat. Limitations: 31 psf Design, Maximum door width 40', Maximum door height 30' 308089 Rev. J Wind load, Series 610/611, C275 slat. Limitations: 36 psf Design, Maximum door width 40', Maximum door height 30' 308090 Rev.J Windload, Series 610/611, C275 slat. Limitations: 41 psf Design, Maximum door width 40', Maximum door height 30' 308091 Rev. J Windload, Series 610/611, C275 slat, Limitations: 50 psf Design, Maximum door width 35', Maximum door height 30' 308092 Rev. K Wind load, Series 610/611/620/621, F265 slat. Limitations: 26 psf Design, Maximum door width 40', Maximum door height 30' 308093 Rev. K Windload, Series 610/611/620/621, F265 slat. Limitations: 31 psf Design, Maximum door width 40', Maximum door height 30' 308094 Rev. K Windload, Series 610/611/620/621, F265 slat. Limitations: 36 psf Design, Maximum door width 40', Maximum door height 30' 2