1855 Beach Ave ROOF20-0014 Shingle/Mod Roof %'1'�''±„,, ROOF NON SHINGLE PERMIT PERMIT NUMBER
�, CITY OF ATLANTIC BEACH ROOF20-0014
V 800 SEMINOLE ROAD ISSUED: 3/4/2020
01:19r ATLANTIC BEACH. FL 32233 EXPIRES: 8/31/2020
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
1855 BEACH AVE ROOF NON SHINGLE SHINGLE AND MOD. ROOF $8816.00
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
169723 1115 THE NAUTILUS
CONDOMINIUM
COMPANY: ADDRESS: CITY: STATE: ZIP:
LOCKHART
CONSTRUCTION & 5380 TIMBERLINE DRIVE JACKSONVILLE FL 32277
ROOFING SERVICES
OWNER: ADDRESS: CITY: STATE: ZIP:
MATHEWS DONNA 3292 FM 1699 AVERY TX 75554
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $95.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $47.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.14
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
Issued Date: 3/4/2020 1 of 2
,-;1\_,,,,,--„, ROOF NON SHINGLE PERMIT PERMIT NUMBER
J
''' CITY OF ATLANTIC BEACH ROOF20-0014
ISSUED: 3/4/2020
800 SEMINOLE ROAD
1 ATLANTIC BEACH. FL 32233 EXPIRES: 8/31/2020
TOTAL: $146.64
Issued Date:3/4/2020 2 of 2
(4i
City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
s 800 Seminole Road ROOF 0ZO—00
0(
j.. Atlantic Beach, Florida 32233-5445 l// `-r
WI Phone(904)247-5826 • Fax(904)247-5845 Cor 3 �� E-mail: building-dept@coab.us Date routed: Z Z lO / z
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: ( EADJ J e)G.ACA-( D artment review required Ye No
� -Planning I- oc K k�� ( CO t�`C Planning &Zoning
Tree Administrator
Project: S K( ikDGLe1V\_0 Public Works
Public Utilities
Roo F Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: [qApproved. ❑Denied. Not applicable
(Circle one.) Comments:
BUILDI '.
PLANNING &ZONING Reviewed by: rri Date: Sly/v�O
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. I 'Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. I (Denied. Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
Building Permit Application OFFICE COPS } �,O:nara. 1�+
City of Atlantic Beach Building OepdRihlM "ALL INFORMATION
HIGHLIGHTED IN GRAY
At
800 Seminole,' Road, Atlantic Beach, FE 32233
IS REQUIRED,
.‘1‘..,_1;7.:._,..:,.._.
% :'
Phone: (904) 247-5826 Email: Bulic;,ing--Deot@coak.us
Jobmidnisr. 16435 Bach hren.r4_ .;yviaLi,$iagyit 3a73S Permit Number: C�OF Z0- 00�z-
li,ept Delacrlption t,(-.,7's .Z'4f~ T ,f�pre,«.t.a C�.,A..M...,E.n. (�_µr,•„)ytk. i 9'.i -1cc't NEI IAA - ltd
ValueidonolWork(ReptacemeestCost)$ S.gli." Heated/Cooled SF Non•Neated,Kooled
• Class of Work: C New °Addition OAJteratIon CSIRepair •=1Niove `-1r rrno ❑Pool OWlndow/Door
• Use of exlsnng/proposed structure(s): DConwnerclal feReskdential
• If an existing structure, =s a fire sprinkler system installed?' Oyes k7No
• Will ttrsjst be removed Inas ;.-!at-on yi:tl proposed aroiec ? r.Yet(mot submit s.ic)rata ''te asmrn•Ai Per flit' Giblo
Describe in detail the type of work to be performed0
.-40h60f Mal/ raeluat 4,4 et Sh.n jcd rcap,..5 er S:1? P'"L , 4 f,rrrti-f-Hoer b.ri...*,rt .,Il . ..� Q = J f
v . 04 -F= M
Florida Product Approval erL 1001-.1' -1-1s-2-1‘• Lf(f)4 .-J.1 -PL2-- 4I3'.i��pk'Arc., ire' '' �•cdUt?approw0m' ( r10 0
Prey Owner Information 00:117- Z
0 m O
Name 4_ - Address : FH ' 0 U O] U
a
H ErO
City A.c. y State T S .Zp 193 % Phone
Li.,
O Q
Owner a Agent Of Agent,Power of Attorney or Agency Letter Required? -__ U cn
Contractor infer CC `Z g w
Name of Company 1,t.r+ ?_(Neto.•r,an,.Q.atz,nri Se.4.ce%,Luc- Qualifying Agent Zn.rete% L.a►wreo :tet fiord it. O rr W
Address(3 t i.,. .,<v..!,& .-1"e Ot( tc,;r.-4. a _ state R. Zip 3A•Ti7 0 e cc m
Office Phone '-/c•'. art 4• 31''5 Job Site Contact Number i'," 3°,,, EZtra
7. w p w
State Certifkarion/Registration 1 t'ar_L,La.Z.Vi it F-Mall L.Zh I.c roe-i_2_(AI r : ea.(.j,T}. t"I I
Architect Name&Phone a 5�� cc us
Engineers Name&Phone tt Cc5
Workers Compensation insurer OA Exempt 16 Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has
commenced prior to the issuance of a prrmt and that all work will be performed to meet the standards of aN the laws regutating
construction m this tuns ectlon.I understand that a separate permit must be secured for ELECTRICAL WORK,PLt1MbING,SIGNS,
WELLS,POOLS,FURNACES,801LERS, HEATERS.TANKS.and AIA CONDITiONE RS,etc. NOTICE:In addition to the requirements of this
permit there may be adat anal restrictions applicable to this property that may be found in the public records of this county,and
there ma^r be additional permits required from other governmental entitles such as water rttarlagement districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT. i certify that all the foregoing Information is accurate and tl'at all work will be done in compliance with a=
applicable Laws regulating COnstruttinn rm-1 zoning
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO ' :T. , FI, •• *,IN* , CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RE t ORDI t, •,f. ' 0 ICE OF COMMENCEMENT. I 1 4000
-,
I:,!� a ) (Sljnature at Gur,racaorl
1 ojdndworr.toI '!I
� �� R •r ? . eforemetha� dayof Sigm • swornto(aaffirmed)beforerouethh_dafto!
y3e2-v ,b, • Fra 'r, oi"i,a ___ __. _ .by
7 /n
I n 3... t i A t/ICK/Lernvl o niiv,
1o^a ( I Srgnmxe of Notary)
3, 10,q_.
0 , ,.,„„;-r 11 of Noeary?
1 �3 3 c� (
1 o; x o n m,'^".v m�'
1 0 u k • , ono is I I Personally Knower OR
I Z :c' ..u d Ideraltcatiorl Id
i Produced •ntlfkation
I E 'A -# .I Identification FL/0 a t y f -1--,,,, hoe of Identification: ..
I '2D N V p
,, O :
N b
1 J W
•'_ __4
NOTICE OF COMMENCEMENT OFFICE COPY
Permit No. A0 "" 001/ Tax Folio No.
State of Florida County of Duval
To whom it may concern:
The undersigned hereby informs you that improvements will be made to certain real property,and in accordance
with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT.
Legal description of property being improved: 09-2S-29E
The Nautilus Condominiums
Dwelling Unit 1855 O/R 7004-2341
Address of property being improved: 1855 Beach Avenue
Atlantic Beach,FL 32233
General description of improvements: remove and replace roofing
Owner Donna Matthews
Address 3292 FM 1699,Avery,TX 75554
/� cy Contractor Lockhart Construction and Roofing Services LLC
f) � iAddress 5380 Timberline Drive.Jacksonville,FL 32277
(1 (/ Phone No. (904)994-3865 Fax No.
Surety(if any)
Address Amount of bond$
Phone No. Fax No.
Name and address of any person making a loan for the construction of the improvements:
Name
Address
Phone No. Fax No.
Name of person within the State of Florida,other than himself or herself,designated by owner upon whom notices or other
documents may be served:
Name
Address
Phone No. Fax No.
In addition to himself or herself,owner designates the following person to receive a copy of the Lienor's Notice as provided in
Section 713.06(2)(b),Florida Statutes. (Fill in at Owner's option.)
Name
Address
Phone No. Fax No.
Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different
date is specified):
THIS SPACE FOR RECORDER'S USE ONLY dip • NER
Date: i + 'Nd
Doc#2020044240,OR BK 19116 Page 648, Signed: � �4 ;;y .,,,�:
Number Pages:1 Before me this , 't d. of Y. /a✓«A. O ��`
Recorded 02/25/2020 03:08 PM, in the County of D r^V AL-- ,State of Florida,ha personally appeared g•!.°�jO•..;t�#
RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL 'Slli�r�6 1 '7. Tari G 5. herein by ro
COUNTY (� `."...<7_, ,
RECORDING $10.00 im�e�f/herself d affirms that all statements and declarations herein are o
'ue 3n a c ra e. c 3 3
3 c rn
S.3 . -
r.
.,T..o,m
.a+.v = ',' -1
n'i i C,a O
Nota y Public at Large,State of if- ,County of-DMA//fig-- 'a-c''D
Myjommission expires: ? ' O V-a'3-3 �,
BErsonally known _ or n CO-"
Produced identification PLe74-tir3rt '2 _ `" P.-,
CertainTeed
FLINTLI4STIC
Application Handbook - Third Edition
An educational program
for professional roofing contractors
FLINTL AST1C•
APPL?C4T7ON SPECIALIST
•
•
i - -
. 45
OFFICE COPY
REVIEWED FOR CODE COMPLIANCE CertainTeed
CITY OF ATLANTIC BEACH SAINT-GOBAIN
SEE PERMITS FOR ADDITIONAL
REQUIREMENTS�yAND CONDITIONS
REVIEWED BY: / '). DATE:_3/ y/?--()
All roofs shall have an overflow system adjacent to drains or scuppers to
collect and direct water of/ the roof should one or more water collection
device fail. Overflows are required by most local building codes and should
be incorporated into any roof design.
Substrate Preparation
All surfaces to which the Flintlastic modified bitumen is to be installed must
be smooth, dry, free from dust or debris, free from settling or distortion, and
free from cracks, knotholes, or other defects.
Primer
Concrete decks must be properly primed with suitable asphalt primer
(meeting ASTM D-41) and the primer must be thoroughly dry.
FlintPrime SA, water-based primer is recommended when installing
self-adhering systems.
Metal flashings must also be primed with a suitable asphalt primer for
metal, and primer must be thoroughly dry and any solvents evaporated
prior to application of membrane flashing.
Base Sheet Application
In new construction or re-roofing applications, an appropriate CertainTeed
base sheet must be installed over the substrate. Unless otherwise
specified, base sheet must be overlapped min. 4" at endlaps and 2" at
sidelaps. For mechanical attachment of the base ply on insulated steel
substrates, the base sheet at a minimum may be fastened with approved
fasteners 12" o.c. on 4" side laps and 18" o.c. in two staggered rows in the
field of the sheet 12" in from the edge.
For nailable substrates, base sheet must be mechanically fastened in
accordance with NRCA standards (fasteners placed every 9" o.c. at
sidelaps and every 18"
o.c. in two staggered
rows in the field of the
sheet; the two stag-
gered rows are placed
12" from each sidelap). "
For non-nailable sur-
faces, spot mopping
with hot asphalt at the
minimum rate of one
12" circle every 24" o.c.
gy
in all directions, using
appropriate type
asphalt at the
11
Roof Relief Vents
If roof relief vents are deemed appropriate they should be of a suitable type
with minimum 4" flange and weather resistant hood, spaced 20' from roof
edge perimeter arid every 40' o.c. thereafter.
Proper Tools
To the professional roofer, the importance
of proper tools is understood. However,
I
here's a brief recap of the ideal tools for
applying Flintlastic modified bitumen:
• For torch applications, a U.L. listed
torch designed specifically for the
application of modified bitumen h
membrane with U.L. listed high-pressure
hose, and U.L. listed regulator. Use an
appropriate length field torch for applying
the field roof membrane, and a "detail" torch for accomplishing
flashing details.
• Propane tank with pressure gauge.
• At least one ABC type fire extinguisher, fully charged (min. 20 lbs.) per
each operating torch and the appropriate number of fire extinguishers at
the kettle area if hot asphalt is used.
• For hot asphalt applications, appropriate asphalt heating, handling and
application equipment. Mop size should be not less than 32 ounces.
• For self-adhering applications, 18" wide, 2"- 4" diameter industrial steel
roller for pressing membrane into place; long-handled (standing) roller
with 1/8"-1/4" nap for applying primer (1/8" nap for smooth surfaces,
1/4' nap for more porous surfaces); caulk gun for applying beads of
FlintBond adhesive; hand-held hot air welding gun such as the Leister
Triac'" (1 10 volt power required) or Primus Sievert PNS-4'" Hot Air Kit;
seam probing tool to check for small voids.
• A roofer's hooked blade knife (the hooked blade is ideal for cutting the
membrane).
• A roofer's trowel with beveled edges and rounded tip (allows smoothing
of details without cutting or marking the membrane); trowels that allow
adequate room between the roofer's gloved fingers and the warm
membrane are the best.
Proper Attire
- Long pants and long sleeved shirts.
17
• Leather work shoes with synthetic or smooth leather soles.
• Leather work gloves that adequately shield the wrist area. Refer also
to the "Safety" section on page 53 for information regarding proper
work attire.
Roof Layout
As with most types of roof installations, Flintlastic modified bitumen
roof installation begins at the low point of the roof with successive rolls
installed so that no laps are against the flow of water. When membrane
is applied with hot asphalt, where roof slope is 1" per foot or less, sidelaps
are installed perpendicular to the direction of the roof slope. In situations
where the roof slope exceeds 1" per foot, rolls are installed with the
sidelaps running parallel to the slope direction. APP modified membranes
can be installed with sidelaps perpendicular to the slope where roof slope is
2" per foot or less (over 2" install sidelaps parallel to roof slope direction).
Additionally, where roof slope exceeds 1" per foot for SBS modified and
self-adhering membranes or 2" per foot for APP modified "back-nailing"
of membrane is required. Refer to the General Recommendations section
of the CertainTeed Commercial Roof Systems Manual for back-nailing
guidelines.
Endlaps are to be staggered. In multi-ply applications, membrane sidelaps
must also be staggered.
. . J4,w!$.1
sp
t Z Whig - _� ....._...,. ... ,#. 1p 4.
� AAn:3'ApartC?
l
7 t
•
t ; it .��.
Base F S llast1C 1 7•.11d5:h 14t4;:'��d ~ Rasa? Fiwtrte} tK,h�e21+18A
SheoTt Ft/WON$+eget Bill.Proitn Cap Sine/ Sheet B LAt*e4'Cap Stw
In multi-ply systems,stagger sidelaps from Stagger field sidelaps from
ir„terply and base sheet sidelaps base sheet sidelaps
Warning: Flintlastic Modified Bitumen application may require the use of
hot asphalt and/or an open flame roofing torch. Improper application
practices may cause physical injury to the applicator or damage to the
property. Refer to the current CertainTeed Commercial Roof Systems
Manual for further information.
18
7
A.,
field
epx :
ewn data Ile kniew
/
/
inhorrtihe:.,
/ --" A, ` Atadrugedyar. ....
\ //
ii
jt+g4+4'dsradtsct'
' sr to thr:nree naTiri:;
..' � Naierspaang:
•. Fw polyester.Fintlastir.membranes
Pleader Shed: •SBS 8 SA 1'-3"slope:3711G.
S"minimum '�.. :...,:: • " .'� s3slope:lb'az.
lap beyond field/. -APP 2'-3"slope:3
thuds en bdh . 7./ 7 ac
sides of the ridge ,.3"slope:1 b'au
6,d Lip :/.
termin.ted ... � For all fiber glass membranes:
at the nailer /./ sit'slope:8'o.c.
Back Nailing Diagram
Basic Application: Flintlastic APP Modified Bitumen
Prepare the substrate as described on page 10. Flintlastic APP modified
bitumen must be applied using a professional roofer's torch. Use of
hand-held roofing torches is recommended and affords the most control.
If multiple burner torching machines are utilized care must be taken to
assure uniform heat application and to avoid overheating of the membrane.
Begin membrane application by -4-M H '- c1.'
unrolling the roll and aligning the f *, �� ,- -.'' `�,�, �.
sidelaps. Re-roll the roll halfway. ,, ,; ,''''r, .
t/y
Standing on the unrolled portion to -
prevent shifting, begin torching the }
exposed polyethylene side of the ,
rolled portion. Walk forward as l'�`''::
you torch, pushing the heated coil , `'" • -
forward and into place with your boot. ctz,1 • x
Position and align the roll
19
' Proper torching procedure involves passing the torch flame in an L" pattern
across the coiled portion of the roll and up the sidelap area. As subsequent
rolls are installed, heat is applied both to the roll and the exposed laps of
the membrane being overlapped onto. As it is heated, the roil becomes
shiny and the polyethylene film melts away. Adequate heat is confirmed
when a uniform flow of melted bitumen compound flows evenly in a
1/4"-1/2" uniform bead that oozes from the applied membrane's edges.
Be sure to heat the entire roll evenly, not just the lap areas, with extra
concentration at the laps. Once at the end of the roll, re-roll the untorched
half, pulling back to beyond the starting point as much as possible, and
repeat the torching procedure.
+►
Nis" rte}
. itis
__ 3 =1. 44 --':-
illy
341
Sidelap
r
_ ,;,r
.... , ,
...,....,
tit. � p, „ __... ,
..,..„„...,„:.,_
„..,,, ,,, ,....„
...,_,8.: __.,,,
Uniform Bitumen
-a it, . a
Flow 1/4”
- 1/7"
Proper torching, in an "L" pattern,assures uniform 1/4"-112.. compound
and flow at laps and adequate heat across the coil
Trim the lower outside corner of the roll at an angle as shown. Overlap
subsequent rolls 3" at sidelaps (or as specified, min. 3") and 6' at endlaps.
Sidelap lines are generally indicated for the applicators' convenience.
20
. .
't:Xtt
3° .
Sidelap \\
.A ss
Overlap Flintlastic STA sidelaps a minimum of 3"
Trim the upper outside corner of the subsequent rolls as shown. All trimmed
corners will be covered with the subsequent rolls.
.:,-0,40.-ri,,,f.'''':. ' • IS:),.. : ' .
-''..\ ''' ''4aS
•
C5‘..... `` .� -1 •
Sym
.
Endlap cuts are made at an angle as shown
21
Material Handling and Storage
• Store rolls upright on pallet in dry area.
• Store indoors in a ventilated area. 'E '
• Keep rolls protected from exposure to heat, sun,
cold and moisture.
• Do not double stack pallets.
• Do not store rolls on their sides.
• Use care in the handling of the rolls.
0• Do not overload the roof. Stagger the rolls across R
the roof. Avoid excessive weight in a concentrated
area. f
Weather Precautions
Do not attempt application if weather conditions and
substrate are not dry.
Do not attempt application if ice, frost, moisture or snow is present.
Rolls can be installed in cold weather if conditions are dry, the rolls have
not been allowed to freeze and proper cold weather handling and storage
procedures are followed. Store rolls in a heated area until just prior to use
and do not proceed with installation if rolls have been allowed to freeze or
weather conditions are unsuitable.
In extremely warm weather, use caution when walking on freshly installed
material to avoid "tracking" warm asphalt; when torch applying smooth
APP membrane in very warm weather the installer may want to utilize a roll
puller and work from front side of the roll (as is the standard torch method
for SBS membranes) to avoid tracking.
Roof Slope and Drainage
The roof surface that is to receive the roof membrane shall have slope to
water collection devices. A drainage calculation determining the quantity of
water that will fall on the roof and how it is to be taken off the roof is a part
of good roof design. Model building codes and good roofing practice have
established a minimum slope for roofs at 1/4":12 running inches. Codes also
recognize the challenges to meet this criterion in reroofing of existing
buildings. All roof areas shall be designed and installed to drain without
holding water on the roof surface. Water collection on the roof surface can
be detrimental to the roof membrane and may void an existing warranty.
Water should not pond in drain sumps or any other collection area that is
covered in roof membrane. Limited and minor areas of ponding may be
accepted by CertainTeed under the terms of the warranty; however,
sacrificial surfacing may be required to maintain the warranty.
10