Loading...
1580 W Park Ter ROOF20-0008 Metal ri' ' " ROOF NON SHINGLE PERMIT PERMIT NUMBER =. � CITY OF ATLANTIC BEACH ROOF20-0008 800 SEMINOLE ROAD ISSUED: 3/4/2020 ° ATLANTIC BEACH, FL 32233 EXPIRES: 8/31/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1580 W PARK TER ROOF NON SHINGLE METAL ROOF $50212.00 TYPE OF REAL ESTATE ! ZONING: ( BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 171943 0000 SELVA MARINA UNIT 02 COMPANY: ADDRESS: CITY: STATE: ZIP: THORNE METAL SYSTEMS 2072 BELLE GROVE TRAC ORANGE PARK FL 32003 INC OWNER: ADDRESS: CITY: STATE: ZIP: PHILLIPS DAVID B 1580 PARK TER W ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $284.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $142.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.39 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.26 TOTAL:$436.65 Issued Date: 3/4/2020 1 of 2 0 IAAPrit ROOF NON SHINGLE PERMIT PERMIT NUMBER .; n) CITY OF ATLANTIC BEACH ROOF20-0008 800 SEMINOLE ROAD ISSUED: 3/4/2020 oit Y.V~ ATLANTIC BEACH, FL 32233 EXPIRES: 8/31/2020 I Issued Date:3/4/2020 2 of 2 ,5.A.N-,7� City of Atlantic Beach APPLICATION NUMBER r4 9, Building Department (To be aned by the Building Department.) 800 Seminole Road h ©TI ZO _O R j Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 -7 7 �oj;jo V E-mail: building-dept@coab.us Date routed: C G City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: (SQL Fk( Zlc. ( E2 V ,..!,,,sgart.7nt review required Yes No ' wilding Applicant: I i--(O21\DE MLS AL Scfs-rein. Planning &Zoning Tree Administrator Project: M F'YPc L. ROO F Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Ri proved. ['Denied. nNot applicable (Circle one.) Comments: BUILDIN� PLANNING &ZONING 3/2/.PC) Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. Denie . n pp ❑ Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Feb 10 20,07:38p Miles Phillips 9043724901 p.1 S '"%' Building Permit Appliication i Updated 10/9/18 ,' ' 111111:,,/ City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY ~ IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us / Job Address: 1580 PARK TER WEST _ Permit Number: K(�n-7F 2 a 1 C�008 Legal Description 27-6 16-2S-29E,SELVA MARINA UNII2 LOT 9 BLK 3 RE# 171943-0000 Valuation of Work(Replacement Cost)$50212.00 Heated/Cooled SF Non-Heated/Cooled • Class of Work: LXNew ❑Addition DAlteration iRepair IlMove EDemo DPool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial /SResidential • If an existing structure,is a fire sprinkler system inTh,lled?: DYes ENo • Will tree{s)be removed in association with proposec proiect? DYes(must submit separate Tree Removal Permit) DNo Describe in detail the type of work to be performed: REMOVE EXISTING SHINGLES AND INSTALL NEW METAL ROOF WITH PEEL AND STICK UNDERLAYMENT Florida Product Approval# 23953.3 _ for multiple products use product approval form Property Owner Information Name DAVID PHILLIPS Address 1580 PARK TER WEST City ATLANTIC BEACH _ state FL zip 32233 Phone 61C" - 6 t (R E-Mail EL 1c oc) cc- c7.s1.,. - —V_ Owner or Agent(IfAgent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company THORNE METAL SYSTEMS, INC. _ Qualifying Agent 64-/v/Pr Cl 7-1.70 e_. Address 1635 FARM WAY,SUITE 406 City MIDDLEBURG State FL Zip 32068 Office Phone G34.284.4153 Job Site Contact Number State Certification/Registration# CCC1325824 E-Mail CTHORNE@THORNEMETALSYSTEMS.COM W Architect Name&Phone# Engineer's Name&Phone# �-i r co Workers Compensation Insurer BUILDERS MUTUAL INSURANCE OR Exempt = Expiration Date 07-10-2020 4 I Q 6 Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation ha Z h- in c: commenced prior to the issuance of a permit and that all weird:will be performed to meet the standards of all the laws regulating J Ca W construction in this jurisdiction. I understand that a separate I;ermit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, 0 6 I- WELLS,POOLS, FURNACES, BOILERS,HEATERS,TANKS,and All: CONDITIONERS,etc. NOTICE:In addition to the requirements of this' G1 0 0 permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and cc a 0: y there may be additional permits required from other governmental entities such as water management districts,state agencies,or 0 Q federal agencies. u- o2Oa9i = OWNER'S AFFIDAVIT: I certify that all the foregoing informa�?icn is accurate and that all work will be doneein campI ante withik' Q r. applicable laws regulating construction and zoning. lL LL © UJ W WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENdiVIENfMA W } °' `= m r.. , � o, n n RESULT IN YOUR PAYING TWICE FOR IMPFI,OVEMENTSTO YOUR(P PERTY. l YOU I U cWn w y TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE 5 cc `-`' RECORD 1 • • ..TICE OF COMMENCEM/IENT. m LU {Sig .._u .f Owner or Agent) (� (Sigr lure of Contractor) Signed and sworn to(or affiiimed)befor me.thi ,6day of Sign,yd and sworn to(or affirme`I) before me this, day of re h ,?0 (fib v�1R ' 110` 4r 'er.` , 9.0;i) ,by ez 0ci r43�• r 4=:rR'r.Fc TONIGINDLESPERGER Signet -of .tart')/' (Signature of '. a• .•_ " MY CO MM ISS I ON#uG 353178 MINIMA.A.DOUGHERTY ��.' EXP IR ES:October 6,2023 1 1 : c56'; ��:'r„- • . . : MY COMA�IlSS10N t(3G 305043 'Peosdartal* ogytiuiDaundetyntersl 1,Personally Known 0' :a; *' I 2023 I J .d ( I Produced Identificati `-.1 e1 Dons:June �' rraouc.eo,aentrrrcatron '?01�,,..���.6grdedTlruNatsYPrrbiCUlldNM11Ms Type of Identification: i-'-1(Z-l a, -77 -i.(4 (- C.7 Type of Identification: _ Doc # 2020026731 , OR BK 19092 Page 493, Number Pages: 1 , Recorded 02/03/2020 02 : 34 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10. 00 Jan 31 20,07:22a Miles Phillips 9043724901 p.2 /ermy 71 /eocJdv—0QDk" OTICE OF COMMENCEMENT OFFICE COPY State of F'<xida Tax Folio No. County of Duval To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated it this NOTICE OF COMMENCEMENT. Legal Description of property being improved:27-616-2S-29E SELVA MARINA UNIT 2 LOT 9 BLK 3 Address of property being improved: 1580 PARK TER WEST,.ATLANTIC BEACH,FL 32233 General description of improvements: REMOVE SHINGLES AND INSTALL NEW METAL ROOF(WITH PEEL&STICK UNDERLAYMENT) Owner: DAVID PHILLIPS Address:15.30 PARK TER WEST.ATLANTIC BEACH,FL 32233 Owner's interest in site of the improvement: SINGLE FAMILY Fee Simple Titleholder(if other than owner): Name: Contractor.THORNE METAL SYSTEMS,INC. Address: 1635 FARM WAY,SUITE 406,MIDDLEFJURG, FL 32068 Telephone No.: (904)264-4353 Fax No:(904)284-4366 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: , Name of person within the State of Florida,other than himse f,designated by owner upon whom notices or other documents may be served:Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year a di'�erent date is specified): ! c$ 'r' NYGQmumgtreiffGG3S31t8 :�� .: rte-------- w EXPIRES:Oaober6,2O3 I THIS SPACE FOR RECORDER'S USE ONLY OWNER- ''. 'IV, °c' ecnd67 Ttvu Hoary Paticunaewrtters Signed: Date: r ✓1.2C Before rni!this f llZO2 the County of Duval,State Of Florida,has personallyapIP • d '_ l' 111 i Notary P%.blic at Lar: ,State•• Florida,a'''uval. Mytonvrissionexpires: IerIII Personally Known: CC,_ or Produced Identification: •'i 17—1(c Z— -C.4 (7 OFFICE COPY • _ •• , I . • _ u• . ._.• ►• -H Standing seam panel was fastened over min.22GA,Grade 33 B-deck @ max.5'o.c.with clip using corrosion resistant(2)#14-10 Dekfast screws per clip through 4"x 5"x 16GA bearing plate and rigid insulation into deck;fastener should be of sufficient length to penetrate min.%"through the deck. Tite-Loc Plus AR sliding clip:2 fasteners per clip,Clip Tab:4.313"wide,50ksi,22GA G90 Coated Steel;Clip Base:2.5"wide,50ksi,18GA G90 coated steel.MSA"Quick Stick HT"40 mil peel&stick or approved equal. Installed over insulation board as per manufacturer's install guidelines.Insulation board:2"min.-4"max.thickness to comply w/ FBC 2017.Slope%:12 or greater in accordance w/FBC 2017. Rib Height:2" **Design Pressure: Clip Spacing: -56.0 PSF @ 48"o.c. -186.4 PSF @ 6"o.c. FL#23953 Tite-Loc Plus: 18"x 24GA Panel over 22GA Metal B-Deck Non-HVHZ Standing seam panel was fastened over min.22GA,Grade 33 B-deck @ max.5'o.c.with clip using corrosion resistant(2)#14-10 Dekfast screws per clip through 4"x 5"x 16GA bearing plate and rigid insulation into deck;fastener should be of sufficient length to penetrate min.'/"through the deck. Tite-Loc Plus AR sliding clip:2 fasteners per clip,Clip Tab:4.313"wide,50ksi,22GA G90 Coated Steel;Clip Base:2.5"wide,50ksi,18GA G90 coated steel.MSA"Quick Stick HT"40 mil peel&stick or approved equal. Installed over insulation board as per manufacturer's install guidelines.Insulation board:2"min.-4"max.thickness to comply w/ FBC 2017.Slope'A:12 or greater in accordance w/FBC 2017.Rib Height:2" **Design Pressure: Clip Spacing: -30.0 PSF @ 48"o.c. -78.5 PSF @ 6"o.c. FL#23953 Tite-Loc Plus: 16"x 0.032"Aluminum over min.19/32"APA Plywood Non-HVHZ Standing seam panel was fastened over min. 19/32"APA rated plywood for new and existing constructions with clip using corrosion resistant(2)#10-12 pancake head type A wood screws per clip into deck;fastener should be of sufficient length to penetrate min.3/16"through the deck. Tite-Loc Plus AR sliding clip:2 fasteners per clip,Clip Tab:4.313"wide,50ksi,22GA G90 Coated Steel;Clip Base:2.5"wide,50ksi,18GA G90 coated steel.'A:12 or greater in accordance w/FBC 2017. **Design Pressure: Clip Spacing: -61.1 PSF @ 24"o.c. -74.1 PSF @ 12"o.c. FL#23953 Edge-Loc 1.0:0.032" nom. 16"coverage Aluminum over 1 2" min.Plywood Non-HVHZ The panel was fastened thru top layer of underlayment members into 15/32"4 ply-CDX plywood attached to framing supports using 8D x 2-1/2"coated ring shank nails spaced @ 6"o.c.Panel fastener:Corrosion resistant#10x15 Pancake Head screws starting 12"from panel end spaced 16"o.c.One#10x15 PH screw secured male and female leg overlap 3"from each end Underlayments applied:H.T. ProQuick(adhesive backed)single layer between adjacent sheets.Fire barrier;single layer of Versashield 5"overlap between adjacent panels. **Design Pressure: -52.5 PSF FL#23953 Large Precision Tile Panel:14.5"x 0.032"Aluminum Non-HVHZ The panel was fastened thru the top layer of underlayment membrane into 5/8"plywood attached to 2 x 10 wood structural framing supports using 8D x 2-1/2"long ring shank nails fastened using corrosion resistant(2)#10-13 x 1"long GP concealor screws. Fasteners located at pre-punched fastener holes @ 12-7/8"o.c.on the top nail flange for each panel.A layer of self- adhering Waterproof Membrane was on top of the plywood sheathing substrate. **Design Pressure: Fastener Spacing: -202 PSF 12.875"o.c. FL#23953 Large Precision Tile Panel: 14.5"x 24GA Steel Non-HVHZ The panel was fastened thru the top layer of underlayment membrane into 5/8"plywood attached to 2 x 10 wood structural framing supports using 8D x 2-1/2"long ring shank nails fastened using corrosion resistant(2)#10-13 x 1"long GP concealor screws.Fasteners located at pre-punched fastener holes @ 12-7/8"o.c.on the top nail flange for each panel.A layer of self- adhering Waterproof Membrane was on top of the plywood sheathing substrate. **Design Pressure: Fastener Spacing: -248 PSF 12.875"o.c. **DESIGN PRESSURE INCLUDES A SAFETY MARGIN OF 2:1 a OFFICE COPY FL 23953 Edge-Loc 1.0 .032" Aluminum Page 33 of 43 k 4 o 1 n 129 1/2" TEST FIXTURE 4 c o J 1 1 r '8 SI o jW 2 3 7Z ty V{2O� O I N iV 0.o ooA ki Of N W O 1:40 Z ^ w g W K O S v O Ey z 7 24" 2x12 #2 SOUTHERN 4 YELLOW PINE TEST iv rm. DECK o w o a • ILaa TEST DECK ELEVATION N.T.S. A;7►,,,,w i, ::,,aBetterTogether. "Fest sample complies with these details Deviations arc noted g O Iteport E1977 01450-18 N Dade 03/10/2015 Vei died lid Alan Rulc OI W at a (FORMER FL 17810) t. s, iANS 52 3/4" 76 3/4" I t ANCHORAGE AND ATTACHMENT NOTES: PLYWOOD SHEATHING TO STRUCTURAL SUPPORT FRAME. CORNER AND FIELD SPECIMENS: 1T I IT r SD x 2-1/4" GALVANIZED RING SHANK COMMON NAILS AT 6" O.C. q q 0 1 R 1 I SHEATHING FELT PAPER. g PERIMETER AND SEAMS; 0.120" x 1 1/4" GALVANIZED ANNULAR RING SHANK ROOFING v I I NAILS WITH 32ga. TIN CAPS SPACED 6" O.C. ` i :' I I INTERMEDIATE ROWS; 0.120" x 1 1/4" GALVANIZED ANNULAR RING SHANK ROOFING I I NAILS WITH 32ga. TIN CAPS SPACED 12" O.C. STAGGERED _ I I A 4' OVERLAP WAS USED WHEN LAYING ADJACENT SHEETS OF FELT PAPER. 5 i I I 5^� I 11 I I VAPOR AND MOISTURE BARRIER. IYHU I I U. SINGLE LAYER OF HT PRO OUIK—STICK MEMBRANE WAS SELF ADHERED TO THE n o m I I .61_1_1 FELT PAPER. A 4" OVERLAP WAS USED BETWEEN ADJACENT SHEETS. 0 . r FIRE BARRIER. 1' 1 II I vii R EACH SHEET OF VERSASHIELD WAS CUT TO THE REQUIRED SIZE AND LAID LOOSELY 4• I 0 II I p p c OVER THE OUIK—STICK HT MEMBRANE. A 5" OVERLAP WAS USED WHEN LAYING44(11 OVERLAP I II 1.. 12" I ADJACENT SHEETS OF VERSASHIELD. ii �� I I I I n — n T—tr. -m—rr n j W 1— I I II 40 R 0 1.1 0 fl .' or. 41 U. I I O le 0 H 0 .��� ,. o o I I I I I ���S z _ILL__ 0 IA /��� cLia •—H_.II 4 •��a+�.. VERSASHIELD g gTIN CAPS WITH — k——I6" FELT PAPER HT PRO OUIK STICK W O ROOF NAILS Z 2 z 4 SHEATHING SYSTEM ELEVATION N.T.S. O N O , 111 1 C.' I. Iii:-;, ;BetterTogether. Test.ample complies wnh these details Deviations are noted g 3 Report+r 61977.01-45048 N Date 03/10/2015 Vcntied Iic Alan Rule 1 n 11- Page Page 35 of 43 (FORMER FL 17810) • FIELD SPECIMEN 0 it.) 0.032" ALUMINUM PANELS i .. 20" COIL WIDTH 1 16" COVERAGE ON 1/2" PLYWOOD ,-- #10 x 1-1/2" PANCAKE TYP, 0.032" HEAD SCREWS 12" FROM ENDS ALUMINUM PANEL 1 q 120" AND 16' ON CENTER / Y7 ii1 SEAM - / L r VERSASHIELD :;>• HT PRO QUK-STICK , A -.1P-. \ 30/ FELT PAPER o• no- 1/2" PLYWOOD 5 ) , / / SHEATHING g „Ai : ‘1111 16" TYP. FIELD INSTALLATION a ZW a i N.T.S nS g ' ® / ' \ X10 X 1-1/2" PANCAKE HEAD SCREW a / 3" FROM EACH PANEL END ONLY , \ a4I / TYP. 0.032' 2,I ALUMINUM PANEL W o i U :,.....--:i r---------------1. 4---..J In_____ \ 5 z_ ' - . --L-. J VERSASHIELD 3 3 J r - - ` �' HT PRO OUK-STICK frIN RIMETER • COVERAGE \ 16" I 301 FELT PAPER o z E PANEL FASTENERS 1/2" PLYWOOD o W HE X CREWS-1/2" PANCAKE r/ P \ \ / / SHEATHING Intertek i a HEAD SCREWS AT 3" O.C. e la a Hu:i,l=tgBetterTogether. PANEL ELEVATION Nit peviaUonawenulcrl O FELD SPECIMEN Report h E1977.01.450-18 Date 03/10/2015 Venfie i Hh Alan Rule 1 pi w Page 36 of 43 (FORMER FL 17810) ••i 0.032" ALUMINUM PANELS CO R N E S P E C I IV E N g . 20" COIL WIDTH _ I a 16" COVERAGE ON 1/2" PLYWOOD / -- #10 a 1-1/2" PANCAKE TYP. 0.032' HEAD SCREWS 6" FROM ENDS / \ ALUMINUM PANEL *.- 120 AND 6" ON CENTER / [ \ 1 e's •. - ....141 I W • PANEL ____ __,..,.../11L ' SEAM ::MEIMIN .1 VERSASHIELD ! • 11•111111111111111: HT PRO QUIK-STICK r.- v moi: �� \ 30 FELT PAPER o r. 1/2" PLYWOOD 4 - SHEATHING J 4 i T TYP, CORNER INSTALLATION g \ ..1 I 2 ' • ...... N.T.S. - I a ga i p ; , / #10 X 1-1/2" PANCAKE HEAD SCREW p j' FROM EACH PANEL END ONLY \ § P I ' / TYP. 0.032" I 1 ALUMINUM PANEL w 1 I L- I , -J -'.fir lb s - � ' HT PRO QUIK-STICK N < 16' \ 30# FELT PAPER o W PERIMETER F PANEL FASTENERS COVERAGE O it #110 X 1-1/2" PANCAKE 1/2" PLYWOOD 'ELY.' HEAD SCREWS AT 3" O.C. \ / SHEATHING il�tertek yty ' II I :,BetterTegether. PANEL ELEVATION N.T.S. PANEL END DETAIL rCsl,ampiccomplies with these details Dcv,anons me notal g o CORNER SPECIMEN Report n E1977.01-450-I8 Date 03/16,2115 Vcniicd fIq Alan Rule W Page 37 of 43