Loading...
301 Ahern St ROOF20-0018 TPO -•:1\---v--,-2,,,,1,,, ROOF NON SHINGLE PERMIT PERMIT NUMBER r�,y � � ROOF20-0018 CITY OF ATLANTIC BEACH ).V 800 SEMINOLE ROAD ISSUED: 3/16/2020 %. 'i19 ATLANTIC BEACH. FL 32233 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: f VALUE OF WORK: 301 AHERN ST ROOF NON SHINGLE 60 MIL DURO LAST TPO $10833.00 ROOFING TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 169737 0010 ATLANTIC BEACH COMPANY: ADDRESS: CITY: STATE: ZIP: Energy Roofing Technology 10153 W US HWY 90 LAKE CITY FL 32055 SE, LLC OWNER: ADDRESS: CITY: STATE: ZIP: AHERN TH PROJECT LLC 830 13 A1A N #120 PONTE VEDRA FL 32082 BEACH WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS 1Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT • BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 • STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 Issued Date: 3/16/2020 1 of 2 ,I.A.'r%, ROOF NON SHINGLE PERMIT PERMIT NUMBER iiiCITY OF ATLANTIC BEACH ROOF20-0018 'til =" ISSUED: 3/16/2020 800 SEMINOLE ROAD �-�'' �� ATLANTIC BEACH. FL 32233 EXPIRES: 9/12/2020 TOTAL: $161.86 Issued Date:3/16/2020 2 of 2 �s =� INSPECTIONS REQUIRED FOR BUILDING PERMITS 4 r1 To verify compliance with building codes,inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: fia Date: Initial: Date: Initial: Power Pole Final Plumbing Silt Fence Final Electrical Piers/Stem Walls Final HVAC Underground Plumbing CC Final Underground Electric Final Building* Foundation/Footing *For new living space:When all construction work including electrical,plumbing, mechanical,exterior finish,grading,required paving and landscaping is complete Slab** and the building is ready for occupancy,but before being occupied •"FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION Swimming Pool Steel • Retaining Wall Footing Swimming Pool Safety • Driveway Electrical Grounding&Bonding Sewer(Building Dept) Swimming Pool Final(Bldg) Sewer Tap(Utilities Dept) Swimming Pool Final(PW) Additional inspections may apply to your project if your project Rough Electric* contains these elements: Rough Plumbing/Top Out* Formed Columns/Beams* Rough Mechanical* Masonry Cell Fill •When all rough electric,plumbing,mechanical are complete but before any work is •When forms and reinforcing steel,anchor bolts,sleeves and inserts,and all covered up. electrical,plumbing and mechanical work is in place,but before concrete is poured. House Wrap Structural Steel* Wall Sheathing •When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. Roof Sheathing OTHER: Tie-down Framing Connections OTHER: Rough Framing OTHER: Roofing In Progress OTHER: Window/Door In-Progress OTHER: Insulation Ceiling Insulation Wall Tpo ROcw ikpcs Exterior Lath r Permit Type Stucco Scratch Coat Exterior Siding In-Progress ROOP ZO ~ 00( 8 Brick Flashing&Ties Permit No. Early Power 301 R 14-Sktv &T Gas Rough Job Addres Gas Final* //►► EGZGt{ ©orik�` When all gas piping is complete and wallboard is installed but before gas is attached to any appliance.All outlets must be capped and pipe pressurized at a minimum of IS lbs. Contractor POST THIS CARD WITH PERMITS AND PERMIT Building Department Public Works/Utilities Fire Department DOCUMENTATION IN FRONT OF BUILDING Phone:904-247-5826 Phone:904-247-5834 Phone:904-630-4789 Fax:904-247-5845 Fax:904-247-5843 Fax:904-630-4203 INSPECTION LINE: 904-247-5814 MUST CALL BY/FM PREVIOUS DAY FOR NEXT DAY INSPECTION Construction Hours per City Code:7am-7pm Weekdays,9amn-7pm Weekends r Cash Register Receipt Receipt Number �iAimCity of Atlantic Beach R11998 41 -r DESCRIPTION I ACCOUNT I QTY I PAID PermitTRAK $485.58 ROOF20-0018 Address: 301 AHERN ST APN: 169737 0010 $161.86 BUILDING $105.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN REVIEW $52.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE SURCHARGES $4.36 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ROOF20-0019 Address: 303 AHERN ST APN: 169737 0010 $161.86 BUILDING $105.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN REVIEW $52.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE SURCHARGES $4.36 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ROOF20-0020 Address: 305 AHERN ST APN: 169737 0010 $161.86 BUILDING $105.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN REVIEW $52.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE SURCHARGES $4.36 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R11998 $485.58 Date Paid: Monday, March 16, 2020 Paid By: Energy Roofing Technology SE, LLC Cashier: CT Pay Method: CREDIT CARD 10 Printed: Monday, March 16, 2020 3:49 PM 1 of 1 r JOB COPY As required by Florida Statute 553,842 and Florida Administrative Code 98.72,please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a building permit We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed products.Statewide approved products are listed online tal www.ffondabuilding org Category/Subcategory Manufacturer i Product Description , Approval Numberis) 1.EXTERIOR DOORS il A.SWINGING M (r ►---- ^ 0 B.SLIDING C.SECTIONAL./ROIL UP .. W N D.OTHER -.... Vl ry, JZ _y__. n U Q 0 ._._. 2.WINDOWS __., Q `7 — A.SINGLE/DOUBLE HUNG _„ -- LU 0 B.HORIZONTAL SLIDER tr Ca 1-7- C.CASEMENT � 00o 4 LUTZd0 D.FIXED ► ® 2 e. E.MULLION -----_ _ 0 F.SKYLIGHTS -J fA _ 1 ry. J 0 t• (' 1 G.OTHER ► '_.... _.a ' 3.PANEL WALLA _ Cli Li 0 Ct. C mr i A.SIDING L 4--- - al 1 B.SOFFITS W Co) h tit C.STOREFRONTS / V CC W D.GLASS BLOCK - > - p -- _a- E.OTHER CC 4.ROOFING PRODUCTS — —__...`._._. A.ASPHALT SHINGLES '-"-"r— B.NON-STRUCTURAL METAL - C.ROOFING TILES --.4-81' -- r- 52-43i D.SINGLE PLY ROOF 1 (Po trot,.. £ve eilka,fd TP/)._-"_. 1��- E.OTHER — — 5.STRUCTURAL COMPONENTS r.---A.WOOD CONNECTORS �.� __ "-- -- B.WOOD ANCHORS C.TRUSS PLATES — -T---4 D.INSULATION FORMS -- --- -- .E.LINTELS -—__--- F. -- -- 6.NEW EXTERIOR ___________-- The products listed below did not demonstrate product approval at plan review.I understand that at the time of inspection of these products,the following „cicn mat un.Hunt im avuatale 10 Cha inspector on the)obsite;1)copy of the product approval.zI pa rfnrmance characteristics which the product was tested and certified to comply w' ,3)copy of the applicable manufacturers installation requirements. Further,I understa,d -ii products may have to be removed it approval cannot be demonstrated during Inspection. ill 9 Contractor re* 'gent Signature Date NOTES:_ 7 Doc # 2019206261, OR BK 18922 Page 2256, Number Pages: 1, R Recorded 09/07/2019 12:49 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY t RECORDING $10.00 JOB COPT PREPARED BY AND RETURN TO: JOSEPH J.VAN ROOM,ESQ. VAN ROOY LAW 9471 BAYMEADOWS ROAD,SUITE 103 JACKSONVILLE,FLORIDA 33225566 Permit No. 2 )O 72jo-0 D/r NOTICE OF COMMENCEMENT • STATE OF FLORIDA ) COUNTY OF DUVAL ) The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,the following information is provided in this Notice of Commencement. I. Description of property: Lot 12,AHERN TOWNHOMES,according to the plat thereof as recorded in Plat Book 71,Pages 96 and 97,of the current Public Records of Duval County, Florida. Street Address:301 Ahern Street,Atlantic Beach,Florida 32233 2. General description of improvement:Development and construction ofTownhome Units. 3. Owner information: a. Name and address: Ahem TH Project,LLC 9471 Baymeadows Road,Suite 103 Jacksonville,Florida 32256 b. Interest in property: Owner c. Name and address of fee simple title holder(if other than Owner): 4. Contractor: a. Name and address: Mulligan Contracting,Inc. 533 10"Avenue N. Jacksonville Beach,Florida 32250 Phone(904)838-98.68 Fax: (904)270-0105 5. Surety: a. Name and address: None. b. Amount of bond: None. 6. Lender: a. Name and address: Forum Capital Partners,LLC 9995 Gate Parkway North,Suite 400 Jacksonville,Florida 32246 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served: a. Name and address: None. 8. In addition to himself,Owner designates the following person(s)to receive a copy of the Lienor's Notice: Name and address: Commercial Loan Administrative Solutions,Inc. Attn:Mindy Lemen 3168 U.S.Highway 17,Suite F Fleming Island,Florida 32003 9. Expiration date of Notice of Commencement: (Expiration date is one year from the date of recording unless a different date is specified.) • Ahern TH Project,LLC,a Florida limited liability company By: Atlantic B Invest(' LC,a Florida limi lability comp is Manag By: 'R Johnston, tsMan STATE OF FLORIDA } COUNTY OF DUVAL ) The foregoing instrument was sworn to and subscribed before me thisay of August 2019,by Richard Johnston, as Manager of Atlantic Beach Investors,LLC,a Florida limited liability company,which is the Manager of Ahern TH Project, LLC,a Florida limited liability company,on behalf of the corn ny,who is personally known to me or[J produced as identification. Print ame: [.i c+ a� ty ;m qu9TAZWFKE NOTARY PUBLIC `;tbaudeemfGG180652 State of Florida `?' re Expires February 25,2022 s•.!::,- mata4Tlaevwranwa as I$ 70i0 (L.:v.1/2, City of Atlantic Beach APPLICATION NUMBER # Building Department (To be assigned by the Building Department.) 'iv 800 Seminole Road ROOF ZD—C) lg - Atlantic Beach, Florida 32233-5445 v Phone(904)247-5826 • Fax(904)247-5845 3 /5 /an 7 0111!) E-mail: building-dept@coab.us Date routed: Cr City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 1�� � 7 Department review required Yes No �uilding_� V Applicant: ko®Pi . Planning &Zoning Tree Administrator Project: C C� t V\ 1 L 0(2-0 LS ( Public Works Public Utilities IP 0 Roo F ( i(- Public Safety y Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: %roved. I 'Denied. ['Not applicable (Circle or- Comments: BUILDIN PLANNING &ZONING Reviewed by: Date: i//0/W TREE ADMIN. Second Review: Approved as revised. ❑Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I 'Approved as revised. I (Denied. [Hot applicable Comments: Reviewed by: Date: Revised 05/19/2017 3ai f—''1Lamming Permit Application C p Updated10/9/18 43, _ City of Atlantic Beach Building Department OFFICE COPY**ALL Y**ALL INFORMATION riv800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY -on 0 IS REQUIRED. Phone: (904)QQ247-58261IEmail: Building-Dept@coab.us Job Address:3O3 A ilaiJ S k'.r /14 rl aA)iC M. AFL 32-3 Permit Number: ' \OO- zo - c o t Legal Description 11 "q(o-;I" s -f Ir Nat'l 1 Nan-1 times 1.404--- 12 RE#/6 ?716 - HHS S.— Valuation of Work(Replacement Cost)$14 A3.3. 01, Heated/Cooled SF //d/. 6 Non- fR"f • Class of Work: Blew ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool OW ower U 3 2020 • Use of existing/proposed structure(s): ❑Commercial residential J� • If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No BY: • Will tree(s)be removed in association with proposed project?❑Yes(must submit separate Tree Removal Permit) ❑No Describe in detail the type of work to be performed: , /7i/S-71/3-// /QOD/C ,o/f/Jeal e0A. '71/ViCl/a.7 Florida Product Approval# P2. / 4;9 JY!dA//f(d - '-� for multiple products use product approval form Property Owner Inform tion / / Name /?/ 9,Q// 7:/ 1 Z../-cZ../-c /.3 /I i Address SP .�4 N /ad City 44te yeRd& State f Zip•e„1 e 8%4 Phone ,186-.3li5-/17/ E-Mail , pa4/7e//10D3 u19/nai/•ed/r7 Owner br Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information/ //JJ //t�t ,of Company Liy aQi /60,A7 Quail ing Agent ��Q12q Address /d/5J Li.1. I/u. 9� City . State Zip j4 A6-5 Office Phone 85 - 7J '15h -. Job Site Contact Number 5 . - L'L' State Certification/Registration#e /3,X95 ; E-Mail ge.Pa/d/. (I .4&+19y god ;/1.921.L/1/7'? Architect Name&Phone# 3b-.9& loo Engineer's Name&Phone# //1� / W [J Workers Compensation Insurer .Qi�9F_t1E/'p/ l's�,S'aG'/7* OR Exempt 0 Expiration Date 0 t . N Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or instal Iati6ns.j Z commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulang) Z 2 M construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SI Q 0 1 WELLS,POOLS,FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirement fThi pZ Q permit,there may be additional restrictions applicable to this property that may be found in the public records of this countttd Q U p there may be additional permits required from other governmental entities such as water management districts,state agengles,p] p federal agencies. d Z CC O Z LL OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with(al -� N applicable laws regulating construction and zoning. O Q I Z W WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MA o O a w m RESULT IN YO R PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTI All us S p TO OBTAIN ANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE w U U) ¢ w RECORD YOUR NO F COMMENCEMENT. w w l .1:-/ -,/ C9certLa tic (Signature o wner or Agent) (Siture of ntractor) iif Tedd and w,orn to(or affirmed)before me this day of Signed and sworn to(or affirmed be •re me this] day of 121/ � '' 7_o7.r� y y_/ R_/49,4 ,by /3 '4' , 7yc° ie (Sign. e• otary) S': at re of N=ttary A »_ ,.. ;:.,10011_ NE HRUDA — I ; / ` t P MY COMMISSIION GG 338932 sonally Known OR Personally Known OR , :.r; �����g; EXPIRES:May 27,2023 [ ]Produced Identification [ ]Produced Identification !F,FF,,o": Bonded TMuNotary PubicUnderwrlten Type of Identification: - Type of Identification: ,..":,it., TONI GINDLESPERGER ,, <'= 1.: MY COMMISSION#GG 353178 --:-.W4�'s:` EXPIRES:October 6,2023 "•. OF F,Y?," Bonded Thru Notary Public Underwriters AHERN TH PROTECT LLC Primary Site Address Official Record Book/Page Thai 830-13 A1A N 120 301 AHERN ST 00071-00096 OFFICE C O PY 9421 PONTE VEDRA,FL 32082 Atlantic Beach FL 32233 301 AHERN ST Property Detail Value Summary RE# 169726-1155 Value Description 2019 Certified 2020In.Progress Value Method CAMA CAMA Tax District USD3 Property Use 0000 Vacant Res<20 Acres Total Building Value $0.00 $0.00 #of Buildings 0 Extra Feature Value $0.00 $0.00 For full legal description see Land Value(Market) $230,000.00 $400,000.00 Legal Desc. Land&Legal section below Land Value(Agric.) $0.00 $0.00 Subdivision 07035 AHERN TOWNHOMES Just(Market)Value $230,000.00 $400,000.00 Total Area 3210 Assessed Value $221,500.00 $243,650.00 The sale of this property may result In higher property taxes.For more information go to Save Our Cap Diff/Portability Amt $8,500.00/$0.00 $156,350.00/$0.00 Homes and our Property Tax Estimator.'In Progress'property values,exemptions and of of r Exemptions $0.00 See below supporting information on this page are part of the working tax roll and are subject to change. Certified values listed in the Value Summary are those certified in October,but may include any official Taxable Value $221,500.00 See below , changes made after certification Learn how the PropAppraisers Office values property, Taxable Values and Exemptions-In Progress If there are no exemptions applicable to a taxing authority,the Taxable Value Is the same as the Assessed Value listed above In the Value Summary box. County/Municipal Taxable Value SJRWMD/FIND Taxable Value School Taxable Value No applicable exemptions No applicable exemptions No applicable exemptions Sales History Book/Page Sale Date Sale Price Deed Instrument Type Code yp Qualified/Unqualified Vacant/Improved 00071-00096 5/30/2018 $100.00 PB-Plat Book Unqualified Vacant Extra Features No data found for this section Land&Legal Land Legal LN Code Use Description Zoning Front Depth Category Land Units Land Type Land Value LN Legal Description 1 0100 RES LD 3-7 UNITS PER AC ARG-M 0.00 0.00 Common 1.00 Lot $400,000.00 1 71-96 21-2S-29E I 2 AHERN TOWNHOMES , 3 LOT 12 Buildings No data found for this section 2019 Notice of Prongsl ProngPr party Taxes Notice(TRIM Notice), Taxing District Assessed Value Exemptions Taxable Value Last Year Proposed Rolled-back Gen Govt Beaches $221,500.00 $0.00 $221,500.00 $0.00 $1,805.49 $1,710.33 Public Schools:By State Law $221,500.00 $0.00 $230,000.00 $0.00 $897.46 $873.08 By Local Board $221,500.00 $0.00 $230,000.00 $0.00 $517.04 $485.21 FL Inland Navigation Dist. $221,500.00 $0.00 $221,500.00 $0.00 $7.09 $6,73 Atlantic Beach $221,500.00 $0.00 $221,500.00 $0.00 $715.11 $679.19 Water Mgmt Dist.SJRWMD $221,500.00 $0.00 $221,500.00 $0.00 $53.47 $53.47 Gen Gov Voted $221,500.00 $0.00 $221,500.00 $0.00 $0.00 $0.00 School Board Voted $221,500.00 $0.00 $230,000.00 $0.00 $0.00 $0.00 Urban Service Dist3 $221,500.00 $0.00 $221,500.00 $0.00 $0.00 $0.00 Totals $0.00 $3,995.66 $3,808.01 Description Just Value Assessed Value Exemptions Taxable Value Last Year $0.00 $0.00 $0.00 $0.00 Current Year $230,000.00 $221,500.00 $0.00 $221,500.00 ' 2019 TRIM Property Record Card(PRC) This PRC reflects property details and values at the time of the original mailing of the Notices of Proposed Property Taxes(TRIM Notices)in August. Property Record Card(PRC) The PRC accessed below reflects property details and values at the time of Tax Roll Certification in October of the year listed. 2019 •To obtain a historic Property Record Card(PRC)from the Property Appraiser's Office,submit your request here: More Information ontact Us I Parcel Tax Record I GIS Map I Map this propgrtyon Google Maps I City Fees Record OFFICE COPY As required by Florida Statute 553,842 and Florida Administrative Code 9B-72,please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a building permlt.We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed products.Statewide approved products are listed online®www.florldabullding.org Category/Subcategory Msnuf*ctu er Product Description Approval Ntmtberis) 1.EXTERIOR DOORS A.SWINGING B.SLIDING C.SECTIONAL/ROLL UP D.OTHER — 2,WINDOWS A.SINGLE/DOUBLE HUNG B.HORIZONTAL SLIDER d C.CASEMENT D.FIXEDn---- E.MULLION F.SKYLIGHTS G.OTHER ►--� 3.PANEL WAU. A.SIDING B.SOFFITS C.STOREFRONTS D.GLASS BLOCK E.OTHER —' 4.ROOFING PRODUCTS A.ASPHALT SHINGLES B.NON-STRUCTURAL METAL _ C.ROOFING TILES ` r D.SINGLE PLY ROOF a 1� I eV E.OTHER r 5.STRUCTURAL COMPONENTS A.WOOD CONNECTORS B.WOOD ANCHORS C.TRUSS PLATES D.INSULATION FORMS E.LINTELS F.OTHERS 6.NEW EXTERIOR ENVELOPE PRODUCTS The products listed below did not demonstrate product approval at plan review.I understand that at the time of Inspection of these products,the following inforrneuon rnva t be evelleble to the Inspector on the Jobslte;1)copy of the product approval,2)parfolmence characteristics which the product was tested and certified to comply w' ,3)copy of the applicable manufacturers Installation requirements. Further,I understa d -—products may have to be removed If approval cannot be demonstrated during Inspection. Contractor r 'gent Signature Date NOTES: 7 Doc IF ZU192Ub261, OR BK 1S922 Page 22b6, Number Pages: 1, • Recorded 09/07/2019 12:49 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 . OFFICE COPY PREPARED BY AND RETURN TO: JOSEPH J.VAN ROOY,ESQ. VAN ROOM LAW 9471 BAYMEADOWS ROAD,SUITE 103 JACKSONVILLE,FLORIDA 32256 ,F Permit No. ►►�/O - r NOTICE OF COMMENCEMENT STATE OF FLORIDA ) COUNTY OF DUVAL ) • The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property: Lot 12,AHERN TOWNHOMES,according to the plat thereof as recorded in Plat Book 71,Pages 96 and 97,of the current Public Records of Duval County, Florida. • Street Address:301 Ahern Street,Atlantic Beach,Florida 32233 2: General description of improvement:Development and construction of Townhome Units. 3. Owner information: a. Name and address: Ahem TH Project,LLC 9471 Baymeadows Road,Suite 103 Jacksonville,Florida 32256 . b. Interest in property: Owner c. Name and address of fee simple title holder(if other than Owner): 4. Contractor: a. Name and address: Mulligan Contracting,Inc. 533 10'"Avenue N. Jacksonville Beach,Florida 32250 Phone:(904)838-98.68 Fax: (904)270-0105 • 5. Surety: a. Name and address: None. b. Amount of bond: None. 6: Lender: a. Name and address: Forum Capital Partners,LLC 9995 Gate Parkway North,Suite 400 Jacksonville,Florida 32246 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served: a. Name and address: None. 8. In addition to himself,Owner designates the following person(s)to receive a copy of the Lienor's Notice: Name and address: Commercial Loan Administrative Solutions,Inc. Attn:Mindy Lemen 3168 U.S.Highway 17,Suite F Fleming Island,Florida 32003 9. Expiration date of Notice of Commencement: (Expiration date is one year from the date of recording unless a different date is specified.) • Ahern TH Project,LLC,a Florida limited liability company By:Atlantic B Investo LC,a Florida limit lability comp is Manag By: R Johnston, Is Man STATE OF FLORIDA } • COUNTY OF DUVAL ) The foregoing instrument was sworn to and subscribed before me thisiay of August 2019,by Richard Johnston, as Manager of Atlantic Beach Investors,LLC,a Florida limited liability company,which is the Manager of Ahern TH Project, LLC,a Florida limited liability company,on behalf of the com y,who r I is personally known to me or[J produced as identification. Print ame: cJESTAZAFFKE NOTARY PUBLIC eommlaaion/00180652' State of Florida .4 Expires February 25,2022 arddlin low Fib Isaania106-.'1tS-?Ms OFFICE COF Ahern The roof itself is structurally sloped at 1/4" per foot which meets code. We have installed 2 layers of FR10, which affords us a Class A fire rating through the single-ply manufacturer Durolast. (already inspected with dry-in under framing inspection) We are installing 1.5" of ISO preliminarily attached which is 5 screws per 4X8 board (not required for R value — insulation will be from interior ceiling — purpose is for strictly for sound barrier) Then we are mechanically attaching 60 MIL Durolast We will do a 30" perimeter and then a 60" perimeter all attached with screws 6" on center to meet the uplift codes. The rest of the roof we will be using 5' sheets for the field. Also attached with screws 6" on center We will terminate the membrane using the Durolast 2" Vinyl Drip edge with Skirt OFFICE COPY Certificate of Authorization No. 29824 C R E E 17520 Edinburgh Dr Tampa,FL 33647 I � TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6"EDITION(2017) Manufacturer: Duro-Last Roofing, Inc. Issued October 12, 2018 525 Morley Drive Saginaw, MI 48601 989-737-3043 www.duro-last.com Manufacturing Plants: Saginaw, MI Jackson, MS Sigoumey, IA Quality Assurance: UL LLC(QUA1743) SCOPE Category: Roofing Subcategory: Single Ply Roof System Code Sections: 1504.3.1, 1504.6, 1507.13.2, 1515.1.1, 1515.1.4, 1523.1.1, 1523.6.2 Properties: Wind Resistance, Physical Properties PRODUCT DESCRIPTION Products Specification Description Duro-Last Designer Series ASTM D 4434 Nominal 50-mil thick single-ply roof membrane composed of a Membrane thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. The membranes are available as Rock-Ply®and Shingle-Ply®prefabricated sections or roll goods. Duro-Last Membrane ASTM D 4434 Nominal 40-mil (DL40), 50-mil(DL50),or 60-mil (DL60)thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. The membranes are available as prefabricated sections or roll goods. Duro-Fleece Membrane ASTM D 4434 Nominal 50-mil(DF50),60-mil(DF60),or 80-mil(DF80) thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim and backed with fleece. Duro-Tuff membranes are available in the following colors:White for all thickness, and Blue,Copper,Charcoal, Green, Light Gray, Patina,and Light Tan for DF50 and DF60 only The membranes are available as roll goods. Duro-Fleece Plus Membrane ASTM D 4434 Nominal 50-mil (DFP50) or 60-mil (DFP60) thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim and backed with fleece. The membranes are available as roll goods. Duro-Tuff Membrane ASTM D 4434 Nominal 50-mil(DT50),60-mil(DT60),or 80-mil (DT80)thick single-ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. Duro-Tuff membranes are available in the following colors:White for all thickness,and Blue, Copper, Charcoal,Green,Light Gray, Patina,and Light Tan for DT50 and DT60 only. The membranes are available as roll goods. DLR12001.14 FL16039-R14 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. ' DURO-LAST ROOFING,INC. CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC REFERENCES Entity Report No. Standard Architectural Testing,Inc.(TST1558) B8983.01-106-18 TAS 117(A)(1995) Architectural Testing,Inc.(TST1558) C0713.01-19.18 TAS 114(J)(1995') Certified Testing Laboratories(TST1577) CTLA 107R TAS 114(J)(1995) Certified Testing Laboratories(TST1577) CTLA 1078-A TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-013-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-014-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-018-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-021-02-01 Rev ASTM D 1761 (2006);TAS 117(A)&(B)(1995); 13 FM 4474(2011);TAS 114(D)&(H)(1995) PRI Construction Materials Technologies(TST5878) DLRI-041-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-029-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-030-02-01 FM 4474(B)(2011);TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-041-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-045-02-01 FM 4474(B)(2011);TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-045-02-02 FM 4474(B)(2011);TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-046-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-047-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-053-02-01 ASTM D 4434(2012);ASTM G 155(2005a) PRI Construction Materials Technologies(TST5878) DLRI-055-02-01 ASTM D 4434(2012);ASTM G 155(2005a) PRI Construction Materials Technologies(TST5878) DLRI-058-02-01 FM 4474(B)(2011);TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-063-02-01 FM 4474(B)(2011);TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-068-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-073-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-073-02-02 FM 4474(B)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-077-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-077-02-02 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-079-02-01.1 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-082-02-01 FM 4474(D)(2011);TAS 114(J)(1995) PRI Construction Materials Technologies(TST5878) DLRI-086-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-086-02-02 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-096-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-096-02-02 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-099-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-100-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-113-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-114-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-115-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-119-02-01 TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-119-02-02 TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-120-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-126-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) DLRI-126-02-02 TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-126-02-03 TAS 114(D)(1995) PRI Construction Materials Technologies(TST5878) DLRI-128-02-01 TAS 117(B)(1995) PRI Construction Materials Technologies(TST5878) NGC-034-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) NGC-035-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) NGC-038-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) PRI Construction Materials Technologies(TST5878) NGC-041-02-01 FM 4474(D)(2011);TAS 114(J)(1995); UL 1897(2012) DLR12001.14 FL16039-R14 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. D DUT ROOFING.INC. j't PVC Single-Ply-Ply Roofing Membranes TECHNICAL SERVICES, LLC Entity Report No. Standard Trinity ERD(TST6049) 02733.01.05-1 FM 4470(2012);TAS 114(J)(1995) Trinity ERD(TST6049) 02744.05.06 FM 4470(2012);TAS 114(J)(1995) Trinity ERD(TST6049) D6760.08.07 FM 4470(2012);TAS 114(J)(1995) Trinity ERD(TST6049) 02750.02.08 ASTM D 4434(2012) Trinity ERD(TST6049) 02762.03.05 TAS 114(D,H&J)(1995) Trinity ERD(TST6049) D35210.08.11-R3 ASTM D 4434(2012) Trinity ERD(TST6049) 040260.03.13-1 TAS 110(2000) Trinity ERD(TST6049) D40280.03.13 TAS 110(2000) Trinity ERD(TST6049) D42320.08.12 FM 4474(D)(2012);TAS 114(J)(2011) Trinity ERD(TST6049) 044450.05.13-2 ASTM D 4434(2012) FM Approvals(TST1867) J.I.2M4A8.AM FM 4470(2012) FM Approvals(TST1867) J.I.3Y5A6 AM FM 4470(2012) FM Approvals(TST1867) J.I.1X2A7.AM FM 4470(2012) FM Approvals(TST1867) 4D6A4.AM FM 4470(2012) FM Approvals(TST1867) 3005604 FM 4470(2012) FM Approvals(TST1867) 3006989 FM 4470(2012) FM Approvals(TST1867) 3008342 FM 4470(2012) FM Approvals(TST1867) 3010289 FM 4470(2012) FM Approvals(TST1867) 3010987 FM 4470(2012) FM Approvals(TST1867) 3014929 FM 4470(2012) FM Approvals(TST1867) 3015816 FM 4470(2012) FM Approvals(TST1867) 3023458 FM 4450(1989) FM Approvals(TST1867) 3026128 FM 4470(2012) FM Approvals(TST1867) 3026508 FM 4450(2012) FM Approvals(TST1867) 3032172 FM 4470(2012) FM Approvals(TST1867) 3033314 FM 4470(2012) FM Approvals(TST1867) 3040346 FM 4470(2012) FM Approvals(TST1867) 3044466 FM 4470(2012) FM Approvals(TST1867) 3040741 FM 4470(2012) FM Approvals(TST1867) 3050118 FM 4470(2012) FM Approvals(TST1867) 3054028 FM 4470(2012) FM Approvals(TST1867) 3063970 FM 4470(2012) 'Standard test method has been found equivalent to FM 4474(2004)referenced by the 2017 FBC. DLR12001.14 FL16039-R14 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK ROOFING,INC. PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.4. 4. In the HVHZ,fastener spacing for insulation attachment is determined using a Minimum Characteristic Force (F') of 275 lbf as demonstrated via testing to TAS 105. If the field tested fastener value is below 275 lbf, then insulation attachment shall not be acceptable. 5. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener resistance value and the MDP for the specified roof system. It is permissible for a qualified professional to submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is found less than required. 6. In the HVHZ, if mechanical attachment through the lightweight insulating concrete to the structural deck is proposed, a field fastener withdrawal test shall be conducted in compliance with TAS 105 to determine equivalent or increased attachment densities. Revised fastener densities shall be submitted utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137. 7. For assemblies containing mechanical attachment,the allowable uplift pressure for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. For perimeter and corner roof zones 2 and 3, the attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in these areas. In the HVHZ, calculations shall be conducted in compliance with RAS 117 and/or RAS 137. 8. Reroofing applications shall be examined in accordance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened roof systems, a field withdrawal resistance test(TAS 105 in the HVHZ;ANSI/SPRI FX-1 or TAS 105 in the non-HVHZ)shall be conducted by a qualified professional to ensure the fastener meets the minimum design load requirements of the roof system. For adhered roof systems, a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1-52, ANSI/SPRI IA-1,or TAS 124 in the non-HVHZ)shall be conducted to confirm conformance of the existing to the minimum design loads. 9. For assemblies containing fully adhered or ribbon adhered attachment, or where extrapolation of the roof system is not permitted, the MDP for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16 without augmentation. 10. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 11. The minimum roof slope shall be 1/4:12 for new construction. 12. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. 13. Fasteners applied in rows may impart concentrated loads to structural components of the building. Designers should consider the fastener spacing of the roof system in relation to the spacing of structural supports when selecting a roof system. DLR12001.14 FL16039-R14 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEKDURO-LAST ROOFING,INC. PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. 2018.10.12 �( V GEN •, S• • S • tiP'•��' 15:55:58 No 74021 r *• :* = Wt/,+waM .rvFrvw, • * = -04'00' O • STATE OF .:4 *-.^ , t P ���� R O Zachary R. Priest, P.E. '•,,Ss, •.......•• ���� Florida Registration No.74021 1,/,�0NA� ,,� Organization No.ANE9641 MMO— CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(7 pages) 2) APPENDIX B—Nomenclature and Approved Assemblies(32 pages) DLR12001.14 FL16039-R14 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK PVC DURO-LAST ROOFING,INC. Single-Ply RoofinggMembranes 7411 TECHNICAL SERVICES, LLC APPENDIX A INSTALLATION Note - Refer to the APPROVED ASSEMBLIES section of this report for specific installation details of a selected roof system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Dispensed using application gun for 2 full seconds into 7/16- Dow ENERFOAMN Foam Sealant inch pilot hole drilled to a depth of 2.5-inch;Fasteners installed within 20-40 seconds after dispensing Duro-Bond Plate 1302 3-inch induction welding plate for PVC membranes;welds not Duro-Bond PVC IW Plate permitted at lap seams Duro-Last 3-inch Metal Plates 3-inch x 3-inch square;0.024-inch thick Galvalume steel Duro-Last#14 Concrete Screw Min.1.25-inch penetration into concrete Duro-Last Cleat Plates Min.2 3/8-inch diameter,0.035-inch thick steel plate with cleats Duro-Last Duro-Coated Hex Head Min. 1.25-inch penetration into concrete Screws Duro-Last Fluted Concrete Nail Min. 1.25-inch penetration into concrete #14 screw;Min. 1-inch penetration into No.2 wood truss;Mtn. Duro-Last#14 HD Fastener 3/4-inch penetration through the top rib of the steel deck or through wood deck Duro-Last#15 Extra Heavy Duty Drill #15 screw;Min.3/4-inch penetration through the top rib of the Fasteners&Plates Point Fastener steel deck or through wood deck Duro-Last Auger Fastener Min.2-inch penetration into substrate Duro-Last Auger Plates Mtn.2-inch diameter steel plate Duro-Last Poly-Plate Min.2-inch diameter,0.335-inch thick glass-filed polycarbonate plate with cleats OMG XHD Fastener #15 screw;Min.3/4-inch penetration through the top rib of the steel deck or through wood deck TRUFAST FM-90 Base Sheet Fastener 2.7-inch steel plate with dual grip shanks;Min.1.7-inch penetration into substrate; TRUFAST Twin Loc Coiled Batten Bar 100 ft.long, 1-inch wide,0.040-inch thick Galvulume coil with pre-punched holes 3-inch o.c. TRUFAST DP#12 Fastener #12 screw;Min.3/4-inch penetration through the top rib of the steel deck TRUFAST 3"Metal Insulation Plate Min.3-inch diameter steel plate TRUFAST Twin Loc-Nail Assembled 2.7-inch steel disk with locking staple;Min.1.8-inch penetration Fastener into substrate TRUFAST Twin Loc-Nail Batten Locking staple;Min.1.8-inch penetration into substrate;for use Fastener with TRUFAST Twin Loc Coiled Batten Bar DEXcell FA Glass Mat Roof Board Mtn. 1/4-inch thick gypsum roof board with fiberglass facer; DEXcell Cement Roof Board Min.7/16-inch thick cement roof board with glass mesh; Min.0.5-inch thick;Extruded polystyrene(XPS)with Insulation Duro-Fold Underlayment Board polypropylene facer,Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard EPS Min.0.5-inch, min.1.8 pcf EPS(HVHZ)or min.1.5 pcf EPS (non-HVHZ);Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard EPS Fan Fold Mtn.0.5-inch,min.1.25 pcf EPS board with polymeric film facer(non-HVHZ only); DLR12001.14 FL16039-R14 Page 1 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. GREEKDURO-LAST ROOFING,INC. PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX A Component Product Installation Detail Min.0.5-inch,min.1.8 pcf EPS(HVHZ)or min. 1.5 pcf EPS Duro-Guard EPS Fiberglass Facer(FGF) (non-HVHZ only)with fiberglass facer,Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard XPS Fan Fold Min.0.5-inch thick;Extruded polystyrene(XPS)with polymeric facer,Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO II-A Duro-Last Duro-Guard ISO II-G Duro-Last Duro-Guard ISO II-H Duro-Last Duro-Guard ISO III-A Min.0.5-inch thick;Min.20 psi polyisocyanurate board with Duro-Last Duro-Guard ISO III-G various facers;Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO III-H Duro-Last Duro-Guard ISO IV-A Duro-Last Duro-Guard ISO Foil Insulation—cont'd Duro-Last Duro-Guard ISO HD Min.2-inch thick composite polyisocyanurate board;Adhered Composite boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO HD-A .Min.0.5-inch thick;Min.90 psi polyisocyanurate board with Duro-Last Duro-Guard ISO HD-G coated fiberglass facers;Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO HD-H Georgia-Pacific DensDeck,Dens Deck Min.0.25-inch thick gypsum roof board with fiberglass facer; Prime Min.0.25-inch thick;Min. 150 psi polyisocyanurate with coated JM Invinsa Roof Board fiberglass facers;Adhered boards shall be a maximum 4-ft x 4- ft Min.0.5-inch ASTM C 578 Type IX(HVHZ)or Type II(non- Insulfoam R-Tech Fan Fold HVHZ)Expanded Polystyrene with polymeric facers;Adhered boards shall be a maximum 4 ft x 4 ft USG SECUROCK Gypsum-Fiber Roof Min.0.25-inch thick gypsum roof board with fiber Board reinforcement; Olybond Classic Applied in 3/4 to 1-inch wide ribbons Duro-Grip Board-Max Apply in 3-inch wide ribbons Duro-Grip CR-20 Adhesive Apply in 3/4 to 1-inch wide ribbons Insulation Adhesive Duro-Grip Insta Stik ,Apply in 3/4 to 1-inch wide ribbons Duro-Grip OlyBond 500 Apply in 3/4 to 1-inch wide ribbons Duro-Grip Trufast Apply in 3/4 to 1-inch wide ribbons Duro-Grip WeatherTite One Step Apply in 1/2 to 3/4-inch wide ribbons Duro-Fleece CR-20 Membrane Adhesive Fleeceback products only;Apply in"splatter pattern"at a rate of 8 Ibs/100-ft2 Duro-Fleece Membrane Adhesive Fleeceback products only;Apply in 3/4-inch wide ribbons Membrane Adhesive Barebacked products only;Fully adhere at a combined rate 60- Duro-Last SB IV Adhesive ft2/gal(Apply 120-ft2/gal to both membrane and substrate). Coverage will vary depending on porosity of substrate. DLR12001.14 FL16039-R14 Page 2 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. K ' DURO-LAST ROOFING,INC. CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX A Component Product Installation Detail Fleece backed membranes:Fully adhere at a rate of 100-ft2/gal to substrate only.Coverage will vary depending on porosity of Membrane Adhesive Duro-Last WB II Adhesive substrate. Cont'd Barebacked membranes;Fully adhere at a rate of 140-ft/gal to substrate only.Coverage will vary depending on porosity of substrate. Min.3-inch tab with min. 1.5-inch welded lap seam for adhered Duro-Last Membrane and induction welded systems; Side-laps shall be installed parallel to the direction of the wood trusses for mechanically attached systems over wood decks;Side-laps shall be installed perpendicular to the direction of the steel deck ribs for mechanically attached systems over steel deck; For in-lap Duro-Fleece Plus Membrane attachment,the center of the plate shall be 1 1/4-inch from the Single-Ply tab edge. Membrane Min.4-inch lap for mechanically fastened systems and min. 3- Duro-Tuff Membrane inch lap for adhered systems with min. 1.5-inch welded lap seam;Side-laps shall be installed parallel to the direction of the wood trusses for mechanically attached systems over wood decks; Side-laps shall be installed perpendicular to the Duro-Fleece Membrane direction of the steel deck ribs for mechanically attached systems over steel deck. For mechanically fastened systems; Min. 4-inch end lap; Min. Thermal Barrier GAF Versashield Solo 2-inch side lap; Shall be laid perpendicular to the direction of membrane Vapor Barrier Duro-Last Vapor Barrier Self-adhered to substrate with optional ELASTOCOL STICK primer Duro-Last Fascia Bar Duro-Last Fascia Bar Cover Duro-Last Fascia Duro-Last Snap Coping Duro-Last 2-Piece Metal"T-Edge" Designed by others and installed in accordance with Duro- Edge Systems Last's current,published installation instructions. Duro-Last Drip Edge Duro-Last 2-Piece Compression Edge Duro-Last Vinyl Coated Metal Duro-Last Gravel Stop Duro-Last Versaterm Edge Celcore S-1 Deck is treated by applying a continuous film with a broom prior to placement of the Celcore lightweight concrete Installed over min. 22 ga., 0.5%vented, B-Deck; Slurry coat Celcore MF with HS Rheology Admixture min. 1/8-inch thick; 1-inch thick EPS board (1 lbs/ft3); Min. 2- Cellular Lightweight inch thick top coat: Celcore PVA curing compound applied at Concrete rate of 300 ft2/gal Elastizell with Zell-Crete Fibers Slurry coat min. 1/4-inch thick; Min. 1-inch thick EPS board(1 lbs/ft);Min.2-inch top coat; Cellular Lightweight Concrete DLR12001.14 FL16039-R14 Page 3 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DURO-LAST ROOFING,INC. PVC Single-Ply Roofingg Membranes ranes AO TECHNICAL SERVICES. LLC APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern o 0 5 per 4ftx8ftboard Q (Max. 6.4ft2 contributory area per fastener) o m 1 6 per 4ftx8ftboard Q R (Max. 6ft2 contributory area per fastener) 1 7-4 12 per • 4ftx8ftboard 0 0 (Max.2.67ft2 contributory area per fastener) DLR12001.14 FL16039-R14 Page 4 of 7 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK PVC Single-Ply ROOFING,INC. Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX A • Insulation/Cover Board Fastening Patterns Description Fastening Pattern m N _SII 16 per T© O 0 4ftx8ftboard m I , I 0 0 0 0 0 0 (Max. 2.0ft2 contributory area per fastener) 0 0 0 0 0 0 ..2 4 18 per (®} 0 0 0 0 4 ft x 8 ft board Z. —m - 0 } _0 0 0 0 0 z.4 (Max. 1.78ft2 contributory area per fastener) iR ' 0 0 0 0 0 .:! • 20 per 070 4ftx8ftboard 101 ,. m �' 0 0 O (Max. 1.6ft2 contributory area per fastener' DLR12001.14 FL16039-R14 Page 5 of 7 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. --., CREEKDURO-LAST ROOFING,INC. PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern 0 0 24 per • 5 v 1-- :_ 0 0 4ftx8ftboard 0 0 0 0-1- , 0 0 m ---1 ;--• � -1 0 0 (Max. 1.33ft2 contributory area per fastener) m 1 0 0 0 0 0 0 0 0 32 per o ®— �' 0 0 0 0 0 P I 4 R x 8 ft board m 4 N 0 I--0 0 0 0 0 0 0 -1 0 0 0 0 0 0 0 9 (Max. 1.0ftcontributory area per fastener) DLR12001.14 FL16039-R14 Page 6 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DURO-LAST ROOFING,INC. PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX A Induction Weld Patterns Description Fastening Array Repeated Using the Geometric Grid Shown Below 18 11* le' 1 per 3.00-ft2 - 12' -- ---------- 0 2.. 0 24 0 4 31' @ 1 per 4.00-ft2 —(e3 0 0 • 0 r• 38' 24' 12' 0 1 per 6.00-ft2 0 DLR12001.14 FL16039-R14 Page 7 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DURO-LAST ROOFING, INC. f, PVC Single-Ply Roofingg Membranes ranes TECHNICAL SERVICES, LLC APPENDIX B NOMENCLATURE The following naming conventions are utilized to specify products in the APPROVED ASSEMBLIES section of this report. Refer to the nomenclature below when deciphering the allowable products for use in the selected roof system. Installation requirements shall be as noted in the APPROVED ASSEMBLIES and INSTALLATION section of this report. Name Definition Approved Insulation One or more layers or combinations of roofing insulation listed in this report or approved under rule 61G20-3, such as gypsum, perlite, polyisocyanurate,polystyrene,or wood fiberboard. Insulation shall be preliminarily secured unless otherwise noted. As Tested Information provided to the report user based on the as tested condition of the roof system CR-20 Duro-Fleece CR-20 Membrane Adhesive;For use with DF or DFP All decks shall be designed by others in accordance with FBC requirements. As Tested deck construction details are described as follows: Concrete Deck Min.P'=2,500 psi at 28 days ------------ CWF Deck Min.2.5-inch thick Tectum I cementitious wood fiber panels Min. 22 ga (FY = min.33 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC; 0.5% Vented for LWIC applications only. The following nomenclature is used to further describe the As Tested condition: _ F<#> 1 Number<#>#12-24 HWH self-drilling screws or equivalent fastener at each flute used to secure the deck --I. to the structural supportssMin.1/4-inch penetration _G<#> I. Min.Grade<-#>of Steel Deck - Steel Deck L<#> { Max.span-Of<#>ft P Min.5/8-inch diameter puddle welds at each flute used to secure the deck to the structural supports Deck Detail S<#> 1/4"-14 HWH x7/8"self-drilling screws or equivalent fastener secured<#>-inch o.c.along the panel side laps W 3/4-inch O.D.flat washer used with indicated fastener HVHZ: Min.19/32-inch-thick APA Span-Rated plywood or wood plank for new construction The following nomenclature is used to further describe the As Tested condition: _ -T<#> j Min.<#>-inch thickness of the plywood or wood plank -_ , Max.span of<#> inches Wood Deck 0.113-<#1>/<#2> 0.113-inch x 2-3/8-inch ring shank nails;Secured <#1>of fasteners at all intermediate supports and at the number<#2>of fasteners at the perimeter of each board 8d-<#1>/<#2> 1 8d ring shank nails; Number<#1> of fasteners at all intermediate supports and at the number <#2> of fasteners at the perimeter of each board Hex-<#1>/<#2> 1/4-inch x 2-inch hex wood screws; Number <#1> of fasteners at all intermediate supports and at the . number<#2>of fasteners at the perimeter of each board DD Min. 1/4-inch thickness Georgia-Pacific DensDeck DDP Min.1/4-inch thickness Georgia-Pacific DensDeck Prime DF One ply of any one of the following products: DF50,DF60,or DF80 membranes DLR12001.14 FL16039-R14 Page 1 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. GREE K DURO-LAST ROOFING,INC. PVC Single-Ply Roofingg Membranes ranes NA i TECHNICAL SERVICES. LLC APPENDIX B Name Definition DFP One ply of any one of the following products: DFP50 or DFP60 membranes DG-BM Duro-Grip Board-Max DG-CR Duro-Grip CR-20 DG-IS Duro-Grip Insta Stik DG-OB Duro-Grip OlyBond 500 DG-TF Duro-Grip Trufast DG-OS Duro-Grip WeatherTite One Step DL One ply of any one of the following products: DL40,DL50,or DL60 membranes DL Plates&#15 Fasteners Duro-Last 3"Metal Plates and Duro-Last#15 Extra Heavy Duty Drill Point Fastener for Steel Decks or Wood Decks DL Plates&Fasteners Duro-Last 3"Metal Plates and Duro-Last#14 HD Fastener for Steel Decks or Wood Decks or Duro-Last#14 Concrete Screws for Concrete Decks DT One ply of any one of the following products: DT50,DT60,or DT80 membranes DXF DEXceII FA Glass Mat Roof Board DXC DEXcell Cement Roof Board DuroBond Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate with Duro-Last#14 HD Fastener for Wood Decks or Steel Decks or Duro-Last#14 Concrete Screw for Concrete Decks Duro-Bond#15 Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate and Duro-Last#15 Extra Heavy Duty Drill Point Fastener for Steel Decks or Wood Decks Duro-Grip Ribbon adhered with any one of the following products: Duro-Grip Board-Max,Duro-Grip CR-20,Duro-Grip Insta Stik,Duro-Grip OlyBond 500,or Duro-Grip WeatherTite One Step One or more layers of the following products: Duro-Guard Duro-Guard EPS,Duro-Guard EPS FGF,Duro-Guard ISO II-A, Duro-Guard ISO II-G, Duro-Guard ISO II-H, Duro-Guard ISO III-A, Duro-Guard ISO Ill-H,Duro-Guard ISO IV-A,or Duro-Guard HD Composite Duro-Guard 11 One or more layers of the following products: Duro-Guard EPS,Duro-Guard ISO II-A,Duro-Guard ISO II-G,or Duro-Last Duro-Guard ISO II-H EPS Duro-Guard EPS FGF Duro-Guard EPS Fiberglass Facer(FGF) HD-A Duro-Guard ISO HD-A HD-G Duro-Guard ISO HD-G HD-H Duro-Guard ISO HD-H Il-A Duro-Guard ISO II-A II-G Duro-Guard ISO II-G DLR12001.14 FL16039-R14 Page 2 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEKgURO LAST ROOFING,INC. PVC Single-Ply RoofinggMembranes ranes TECHNICAL SERVICES, LLC APPENDIX B Name Definition Il-H Duro-Guard ISO II-H IIIA Duro-Guard ISO III-A III-G Duro-Guard ISO III-G I/I-H Duro-Guard ISO III-H IV-A Duro-Guard ISO IV-A LW/C Poured-in-place;Cellular Lightweight Concrete with encapsulated insulation board MCRF Minimum Characteristic Resistance Force as determined by TAS 105 for the named fastener in the selected assembly MDP Maximum Design Pressure Where assemblies are used to recover an existing roof, the existing roof shall consist of only one layer of roofing, i.e. recovering a previously Recover recovered roof is not permitted. Recover roofing shall be conducted in compliance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened assemblies, the existing roof insulation thickness may be contributory in meeting the minimum insulation thickness requirements for a given roof system. SB IV Duro-Last SB IV Adhesive;For use with DL,or DT SR USG SECUROCK gypsum-fiber roof board,Min. 1/4-inch thickness WB I1 Duro-Last WB II Adhesive;For use with DF,DFP, DL,or DT, DLR12001.14 FL16039-R14 Page 3 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. ( DURO-LAST ROOFING, INC. CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX B APPROVED ASSEMBLIES The following notes shall be observed when using the roof system tables below. 1. MDPs were calculated using a 2:1 margin of safety per FBC Section 1504.9 and 1523.4. MDP shall exceed-45 psf for use in the HVHZ. 2. Refer to LIMITATIONS and NOMENCLATURE sections of this evaluation when using the table(s)below. Items italicized refer to specific nomenclature used in this report. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected roof system. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated roof system. 5. As Tested information for roof deck construction is provided for information only. The addition of the As Tested deck information does not obviate the requirement for rational design of the roof deck and roof deck attachment in accordance with FBC requirements. 6. Duro-Last Vapor Barrier may be installed direct to deck prior to installing the roof assembly components for following assembly types: C-M-#, C-W-#, G- M-#, LC-M-#, LS-M-#, S-M-#,S-W-#,W-M-#,and W-W-#. Roof System Numbers and Definitions C-A-# Assemblies with All Layers Adhered over Concrete Deck(New or Existing) C-AM-# Assemblies with Adhered Membranes over Insulated Concrete Deck(New, Existing,or Recover) C-M-# Mechanically Fastened Assemblies over Concrete Deck(New,Existing,or Recover) C-W-# Induction Welded Assemblies over Concrete Deck(New,Exiting,or Recover) CW-A-# Assemblies with All Layers Adhered over CWF Deck(New or Existing) CW-M-# Mechanically Fastened Assemblies over CWF Deck(New,Existing,or Recover) G-A-# Assemblies with All Layers Adhered over Gypsum Deck(New or Existing) G-M-# Mechanically Fastened Assemblies over Poured Gypsum Deck(New or Existing) LC-A-# Lightweight Concrete Assemblies with All Layers Adhered over Concrete Deck(New or Existing) LC-M-# Mechanically Attached Lightweight Insulating Concrete Assemblies over Concrete Deck(New or Existing) LS-A-# Lightweight Concrete Assemblies with All Layers Adhered over Steel Deck(New or Existing) LS-M-# Mechanically Attached Lightweight Insulating Concrete Assemblies over Steel Deck(New or Existing) R-A-# Recover Assemblies with All Layers Adhered R-M-# Mechanically Fastened Recover Assemblies R-W-# Induction Welded Recover Assemblies S-A-# Assemblies with All Layers Adhered over Steel Deck(New or Existing) S-AM-# Assemblies with Adhered Assemblies over Steel Deck(New,Existing or Recover) S-M-# Mechanically Fastened Assemblies over Steel Deck(New,Existing,or Recover) S-W-# Induction Welded Assemblies over Steel Deck(New,Existing,or Recover) W-A-# Assemblies with All Layers Adhered over Wood Deck(New or Existing) W-M-# Mechanically Fastened Assemblies over Wood Deck(New or Existing,or Recover) W-W-# Induction Welded Assemblies over Wood Deck(New,Existing,and Recover) DLR12001.14 FL16039-R14 Page 4 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING,INC. GREEK PVC Single-Ply Roofing Membranes 111. TECHNICAL SERVICES. LLC APPENDIX B Assemblies with All Layers Adhered over Concrete Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment (psf) EPS FGF,Il-A, ll-G, Min.0.5-inch Duro-Grip or DG-TF ribbon Il-H,Ill-A,Ill-H, IV A, Duro-Grip or DG-TF ribbon DL,DT,OF or -60 C-A-1 Duro-Guard II adhered 12-inch o.c. HD-A, HD-G,HG-H, adhered 12-inch o.c. DFP WB ll,SB IV,or CR-20 (Urn.9) DDP,or SR Min.1-inch DG-TF OPTIONAL DG-TF DL,DT,DF or -90 C-A-2 III-H ribbon adhered 12-inch DDP,DXC,DXF, ribbon adhered 12 inch o.c. DFP WB II,SB IV,or CR-20 (Lim.9) o.c. HD-A,HD-G,or SR OPTIONAL Min. 1-inch DG-TF DG-TF DL,DT,DF or -97.5 C-A-3 EPS,Il-A,Il-G, ribbon adhered 12-inch DXF or SR ribbon adhered 12-inch o.c. DFP WB II,SB IV,or CR-20 (Lim.9) Il-H,Ill-A,or o.c. Ill-G C-A-4 - - - - DL SB IV -102.5 (Lim.9) OPTIONAL Min. 1-inch DG-TF DG-TF DL,DT,DF or -112.5 C-A-5 EPS,11 A,11-G, ribbon adhered 12-inch o.c. HD-H ribbon adhered 12-inch o.c. DFP WB II, SB IV,or CR-20 (Lim.9) Il-H,Ill-A,or 111-G Min.1-inch C A� EPS,1l A, Il-G, DG-TF OPTIONAL DG-TF DL,DT,DF or WB II,SB IV,or CR-20 -120 II-H,Ill-A,or ribbon adhered 12-inch o.c. DDP, HD-G,or DXC ribbon adhered 12-inch o.c. DFP (Lim.9) III-G OPTIONAL Min.1-inch DG-TF DG-TF DL,DT,DF or -120 C-A-7 EPS,1l-A,11-G, ribbon adhered 12-inch o.c. HD-G ribbon adhered 12-inch o.c. DFP WB II,SB IV,or CR-20 (Lim.9) Il-H,Ill-A,or IlI-G C A 8 Min.1-inch DG-TF OPTIONAL DG-TF DL,DT,DF or WB II,SB IV,or CR-20 -127.5 Il-H ribbon adhered 12-inch o.c. DDP or DXC ribbon adhered 12-inch o.c. DFP (Lim.9) C-A-9 DL WB II -127.5 (Lim.9) Min.1-inch Duro-Grip OPTIONAL Duro-Grip DL,DT,DF or -135 C A-10 EPS,IPA,//-G, ribbon adhered 12-inch o.c. (except EPS) ribbon adhered 12-inch o.c. DFP WB II, SB IV,or CR-20 (Lim.9) Il-H DXC or DXF Min.0.5 inch DG-IS DL,DT,DF or -135 C-A-11 EPS FGF,Il-A, ribbon adhered 12-inch o.c. DFP WB Il,SB IV,or CR-20 (Lim.9) or Il-H C-A-12 Min.0.5-inch DG-IS DL,DT,DF or WB II, SB IV,or CR-20 -142.5 ll-G ribbon adhered 12-inch o.c. DFP (Lim.9) Min.0.5 inch DG-OS DL,DT,DF or -150 C-A-13 EPS FGF, Il-A, ribbon adhered 12-inch o.c. - DFP WB II, SB IV,or CR-20 (Urn.9) or Il-H DLR12001.14 FL16039-R14 Page 5 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. ACREEK K PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX B Assemblies with All Layers Adhered over Concrete Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment (psf) OPTIONAL DG-TF DG-TF DL,DT,DF or -165 C-A-14 Min.1-inch ribbon adhered 12-inch o.c. DDP ribbon adhered 12-inch o.c. DFP WB ll,SB IV,or CR-20 (Lim.9) EPS C-A-15 - - DXC DG-TF DL,DT,DF or WB ll,SB IV,or CR-20 -180 ribbon adhered 12-inch o.c. DFP (Lim.9) C-A-16 Min.0.5-inch DG-CR or DG-BM HD-G DG-CR or DG-BM DL,DT,DF or WB II,SB IV,or CR-20 -172.5 Duro-Guard 11 ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. DFP (Lim.9) C-A 17 Min.0.5-inch DG-OB HD-H,Ill-A,111-H, DG-OB DL,DT,DF or WB II,SB IV,or CR-20 -172.5 EPS,Il-A,!I-H ribbon adhered 12-inch o.c. DDP,SR,EPS FGF ribbon adhered 12-inch o.c. DFP (Lim.9) Min.0.5-inch DG-CR or DG-BM DL,DT,DF or -180 C-A-18 EPS FGF,Il-A, ribbon adhered 12 inch o.c. DFP WB I1, SB IV,or CR-20 (Lim.9) or ll-H C-A-19 Min.0.5-inch DG-OS SR or EPS FGF DG OS DL,DT,DF or WB II, SB IV,or CR-20 -195 Il-G ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. DFP (Lim.9) Min.0.5-inch DG-OB WB II(Fleece only), -195 C A 20 EPS FGF,I!A, ribbon adhered 12-inch o.c. DT,DF or DFP SB IV,or CR-20 (Lim.9) or ll-H C A-21 Min.0.5-inch DG-OB DDP,EPS FGF, DG-OB DL,DT,DF or WB ll, SB IV,or CR-20 -195 EPS,11-A,orll-H ribbon adhered 12-inch o.c. 111-A,or SR ribbon adhered 12-inch o.c. DFP (Lim.9) C-A-22 Min.1-inch DG-CR or DG-BM DDP DG-CR or DG-BM DL,DT,DF or WB II, SB IV,or CR-20 -202.5 Duro-Guard Il ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. DFP (Lim.9) C A-23 Min.0.5-inch DG-OS DL- - ,DT,DF or WB II, SB IV,or CR-20 -202.5 ll-G ribbon adhered 12-inch o.c. DFP (Lim.9) C A 24 Min. 1.5-inch DG-CR or DG-BM DDP DG-CR or DG-BM DL,DT,DF or WB II, SB IV,or CR-20 -225 Duro-Guard 11 ribbon adhered 4-inch o.c. ribbon adhered 4-inch o.c. DFP (Lim.9) C A 25 Min.0.5-inch DG-CR or DG-BM DL,DT,DF or WB II, SB IV,or CR-20 -232.5 1/-G ribbon adhered 12-inch o.c. DFP (Lim.9) C A-26 OPTIONAL DG-CR or DG-BM DXF DG-CR or DG-BM DL,DT,DF or WB II -300 II-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. DFP (Lim.9) C-A-27 OPTIONAL DG-CR or DG-BM DXF DG-CR or DG-BM DL SB IV -300 ll-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) C-A 28 OPTIONAL DG-CR or DG-BM DXF DG-CR or DG-BM DF Duro-Fleece Membrane -300 /i-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. Adhesive (Lim.9) C-A-29 OPTIONAL DG-CR or DG-BM DXF DG-CR or DG-BM DFP CR-20 -300 II-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) C-A-30 OPTIONAL DG-OB or DG-OS DXF DG-OB or DG-OS DL,DT,DF or WB I1 -382.5 Il-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. DFP (Lim.9) C A-31 OPTIONAL DG-OB or DG-OS DXF DG-OB or DG-OS DL SB IV -382.5 Il-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) OPTIONAL DG-OB or DG-OS ribbon DG-OB or DG-OS Duro-Fleece Membrane -382.5 C A-32 /l-A adhered 12-inch o.c. DXF ribbon adhered 12-inch o.c. DF Adhesive (Lim.9) DLR12001.14 FL16039-R14 Page 6 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. -4 CR Lr K PVC Single-Ply Roofing Membranes AIIII TECHNICAL SERVICES. LLC APPENDIX B Assemblies with All Layers Adhered over Concrete Deck(New or Existing) _ System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment (psf C-A-33 OPTIONAL DG-OB or DG-OS ribbon DXF DG-OB or DG-OS DFP CR-20 -382.5 11-A adhered 12-inch o.c. ribbon adhered 12-inch o.c. _ (Lim.9) OPTIONAL DG-OB, DG-OS or DG-IS DG-OB, DG-OS or DG-IS DL,DT,DF or -382.5 C-A-34 11-A ribbon adhered 12-inch o.c. DXC _ ribbon adhered 12-inch o.c. DFP WB 11 (Lim.9) OPTIONAL DG-OB,DG-OS or DG-IS DG-OB,DG-OS or DG-IS -382.5 C-A-35 II-A ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DL SB IV (Lim.9) C A-36 OPTIONAL DG-OB,DG-OS or DG-IS DXC DG-OB,DG-OS or DG-IS DF Duro-Fleece Membrane -382.5 1I-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. Adhesive (Lim.9) C-A-37 OPTIONAL DG-OB,DG-OS or DG-IS DXC DG-OB,DG-OS or DG-IS DFP CR-20 -382.5 Il-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. _ (Lim.9) C-A-38 Min. 1.5-inch Olybond Classic SR Olybond Classic DL,DT,DF or WB 11 SB IV,or CR-20 -457.5 ll-A or 11-H ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. DFP (Lim.9) OPTIONAL ASTM D 312,Type IV ASTM D 312,Type IV DL,DT,DF or -495 C-A-39 11-A hot asphalt DXF hot asphalt DFP WB 11 (Lim.9) OPTIONAL ASTM D 312,Type IV ASTM D 312,Type IV -495 C-A-40 Il-A hot asphalt DXF hot asphalt DL _ SB IV (Lim.9) C-A 41 OPTIONAL ASTM D 312,Type IV DXF ASTM D 312,Type IV DF Duro-Fleece Membrane -495 II-A hot asphalt hot asphalt _ Adhesive (Lim.9) OPTIONAL ASTM D 312,Type IV ASTM D 312,Type IV -495 C-A-42 Il-A hot asphalt _ DXF _ hot asphalt DFP CR-20 (Lim.9) C-A-43 DF or DFP CR-20 -502.5 (Lim.9) C-A-44 DF or DFP WB II -502.5 (Lim.9) C-A-45 DFP WB II -672.5 (Lim.9) C-A-46 DFP CR-20 -1,025 (Lim.9) Assemblies with Adhered Membranes over Insulated Concrete Deck(New,Existing or Recover) Top Insulation System Base Base Insulation Top Insulation or Base Sheet MDP No. Insulation Attachment or Attachment Membrane Membrane Attachment (psf) Base Sheet Min. Min.1.5-inch C AM-1 0.5-inch Simultaneously Il-A,II-G,Ill-A, DL Plates&Fasteners secured DL,DT,DF or WB II, SB IV,or CR-20 -45 Approved secured with top layer Ill-H,IV-A,or Min. 16 per 4 ft x 8 ft board DFP (Lim.9) Insulation 0.5-inch SR Min. C AM 2 0.5-inch Simultaneously JM Invinsa Roof DL Plates&Fasteners secured DL SB IV -45 Approved secured with top layer Board 16 per 4 ft x 8 ft board (Lim.9) Insulation DLR12001.14 FL16039-R14 Page 7 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 4CR E r DURO-LAST ROOFING, INC. CK PVC Single-Ply Roofing Membranes 1 all TECHNICAL SERVICES, LLC APPENDIX B Assemblies with Adhered Membranes over Insulated Concrete Deck(New,Existing or Recover) - Top Insulation System Base Base Insulation Top Insulation or Base Sheet MDP No. Insulation Attachment or Attachment Membrane Membrane Attachment Base Sheet (psfl Min. C AM 3 0.5-inch Simultaneously SR DL Plates&Fasteners secured at DL,DT,DF or W811, SB IV,or CR-20 -45 Approved secured with top layer a rate of one fastener per 1.33-ft2 DFP (Lim.9) Insulation Min.1.5-inch DL Plates& C-AM-4 A roved #15 Fasteners Min.0.25-inch DD Duro-Fleece Membrane Adhesive DL,DT,DF or -45 pp secured at a rate of or Il-A ribbons spaced 6-inch o.c. DFP WB ll, SB IV,or CR-20 (Lim.9)16 per 4 ft x 8 ft board Min.1.5-inch ll-A, OPTIONAL II-G,Il-H,Ill-A; C-AM-5 Approved Simultaneously Min.2-inch IV A; DL Plates&Fasteners secured at DL,DT,DF or WB Il, SB IV,or CR-20 -45 Insulation secured with top layer or Min.0.5-inch SR or DDP OPTIONAL Simultaneously DL Plates&Fasteners secured at DL,DT,DF or -45 C-AM-6 Approved secured with top layer SR or DDP a rate of 16 per 4 ft x 8 ft board DFP WB II, SB IV,or CR-20 Insulation (Lim.9) Min.1.5-inch Simultaneously DL Plates&Fasteners secured at DL,DT,DF or -67.5 C-AM-7 Approved secured with top layer DDP or SR a rate of 24 per 4 ft x 8 ft board DFP WB II, SB IV,or CR-20 Insulation (Lim.7) OPTIONAL Min.1.5-inch II-A, C-AM-8 Approved Simultaneously II-G or Ill-A;or DL Plates&Fasteners secured at DF or DFP WB II -67.5 Insulation secured with top layer Min.2-inch IV-A a rate of 24 per 4 ft x 8 ft board (Lim.7) Min.1.5 inch Simultaneously DL Plates&Fasteners secured at DL,DT,DF or -67.5 C-AM-9 Approved secured with toplayer DDP or SR a rate of 20 WB II,SB IV,or CR-20 Insulation y per 4 ft x 8 ft board DFP (Lim.7) OPTIONAL Simultaneously DL Plates&Fasteners secured at DL,DT,DF or -90 C-AM-10 Approved secured with top layer Min.2-inch IV-A a rate of 16 per 4 ft x 8 ft board DFP SB IV or WB II Insulation (Lim.7) Induction Welded Assemblies over Concrete Deck(New,Existing,or Recover) System Base Insulation Top Layer Top Insulation MDP No. Base Layer Insulation Attachment Insulation Attachment Membrane Attachment (psf) OPTIONAL Simultaneously secured Duro-Bond secured Induction welded to each -45 C-W-1 Approved Insulation with top layer Approved Insulation 6 per 4 ft x 8 ft board DL or DT _ insulation plate (Lim.9) Duro-Bond secured C-W 2 OPTIONAL Simultaneously secured Min.1.5-inch Induction welded to each -45 Approved Insulation with top layer Approved Insulation 6-inch o.c.in rows DL or DT insulation plate (Lim.7) spaced 60-inches o.c. _ Duro-Bond secured C-W-3 OPTIONAL Simultaneously secured Min. 1.5-inch Induction welded to each -45 Approved Insulation with top layer Approved Insulation 12-inch o.c.in rows DL60 insulation plate (Lim.7) spaced 48-inches o.c. DLR12001.14 FL16039-R14 Page 8 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. _ DURO-LAST ROOFING, INC. `. :4 , CREEK PVC Single-Ply Roofing Membranes 4111 TECHNICAL SERVICES. LLC APPENDIX B Induction Welded Assemblies over Concrete Deck(New,Existing,or Recover) _ System Base Insulation Top Layer Top Insulation MDP No. Base Layer Insulation Attachment Insulation Attachment Membrane Attachment (psf) Duro-Bond secured OPTIONAL Simultaneously secured Min. 1.5-inch Induction welded to each -45 C-W� in rows DL60 Approved Insulation with top layer Approved Insulation 6-inch o.c. insulation plate (Lim.7) spaced 120-inches o.c. Duro-Bond secured OPTIONAL Simultaneously secured Min. 1.5-inch Induction welded to each -52.5 C W 5 in rows DL or DT Approved Insulation with top layer Approved Insulation 6-inch o.c. insulation plate (Lim.7) spaced 72-inches o.c. Duro-Bond secured OPTIONAL Simultaneously secured Min. 1.5-inch Induction welded to each -52.5 C-W-6 6-inch o.c.in rows DL60 Approved Insulation with top layer Approved Insulation spaced 96-inches o.c. insulation plate (Lim.7) OPTIONAL Simultaneously secured Min. 1.5-inch Duro-Bond secured Induction welded to each -52.5 C-W-7 Approved Insulation with top layer . Approved Insulation _ 12 per 4 ft x 8 ft board DL or DT _ insulation plate (Lim.7) OPTIONAL Simultaneously secured Duro-Bond secured Induction welded to each -52.5 C-W-8 Approved Insulation with top layer Approved Insulation 12 per 4 ftx 8 ft board _ DT insulation plate (Lim.7) Duro-Bond secured OPTIONAL Simultaneously secured Min. 1.5-inch Induction welded to each -82.5 C-W-g in rows DL or DT Approved Insulation with top layer Approved Insulation 6-inch o.c. insulation plate (Lim.7) spaced 48-inches o.c. Duro-Bond secured OPTIONAL Simultaneously secured Min. 1.5-inch Induction welded to each -82.5 C W 10 in rows DL60 Approved Insulation with top layer Approved Insulation 6-inch o.c. insulation plate (Lim.7) spaced 60-inches o.c. Duro-Bond secured OPTIONAL Simultaneously secured Min. 1.5-inch Induction welded to each -82.5 C-W-11 Approved Insulation with top layer Approved Insulation 6-inch o.c.in rows DL60 insulation plate (Lim.7) spaced 48-inches o.c. Mechanically Fastened Assemblies over Concrete Deck(New, Existing,or Recover) System Insulation Membrane Fasteners Attachment MDP No. (psf) -30 Min Inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail Fastened 12-inch o.c.along (Lim.7; C-M-1 Approved Insulation DL with Duro-Last Poly-Plates or Cleat Plates 6-wide tabs spaced 120-inch o.c. Non- HVHZ) Min.0.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail Fastened 12-inch o.c.along -45 C-M-2 Approved Insulation DL with Duro-Last Poly-Plates or Cleat Plates 3-inch wide tabs spaced 60-inches o.c. (Lim.7) Min.0.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail Fastened 6-inch o.c.along -45 C-M-3 Approved Insulation DL with Duro-Last Poly-Plates or Cleat Plates 3-inch wide tabs spaced 84-inches o.c. (Lim.7) C-M-4 Min.0.5-inch DT Duro-Last#14 Concrete Screw with Fastened 12-inch o.c.within -45 Approved Insulation Duro-Last Cleat Plates laps spaced 116-inch o.c. (Lim.7) C-M-5 Min 1.5 inch DT Duro-Last#14 Concrete Screw with Duro-Last Cleat Plates Fastened 12 inch o.c.within -45 Approved Insulation laps spaced 56-inch o.c. (Lim.7) Duro-Last#14 Concrete Screw or Fluted Concrete Nail with C-M 6 Min.0.5-inch DL Duro-Last Poly-Plates Fastened 18-inch o.c.along -52.5 Approved Insulation or Cleat Plates 3-inch wide tabs spaced 28-inches o.c. (Urn.7) DLR12001.14 FL16039-R14 Page 9 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING,INC. CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX B Mechanically Fastened Assemblies over Concrete Deck(New, Existing,or Recover) System Insulation Membrane Fasteners Attachment MDP No. (psf) C-M-7 Min.0.5-inch DL Duro-Last#14 Concrete Screw or Fluted Concrete Nail with Fastened 6-inch o.c.along -52.5 Approved Insulation Duro-Last Poly-Plates or Cleat Plates 3-inch wide tabs spaced 60-inches o.c. (Lim.7) C-M 8 Min.0.5-inch DL Duro-Last#14 Concrete Screw or Fluted Concrete Nail with Fastened 6-inch o.c.along -52.5 Approved Insulation Duro-Last Poly-Plates or Cleat Plates 6-inch wide tabs spaced 120-inches o.c. (Lim.7) Fastened 12-inch o.c.along C M-9 Min.1.5-inch DL Duro-Last#14 Concrete Screw or Fluted Concrete Nail with 6-inch wide tabs spaced 57 inches o.c. -52.5 Approved Insulation Duro-Last 3-inch Metal Plates Tab Sealer 4725 applied at 60 ft2/gal. (Lim.7) Fastened 12-inch o.c.along C-M-10 Min.1.5-inch DL Duro-Last#14 Concrete Screw or Fluted Concrete Nail with 6-inch wide tabs spaced 84-inches o.c. -52.5 Approved Insulation Duro-Last 3-inch Metal Plates Tab Sealer 4725 applied at 60 ftZ/gal. (Lim.7) C M 11 Min.0.5-inch DL Duro-Last#14 Concrete Screw or Fluted Concrete Nail with Fastened 6-inch o.c.along -60 Approved Insulation Duro-Last Cleat Plates 3-inch wide tabs spaced 84-inches o.c. (Lim.7) Min.0.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail with Fastened 6-inch o.c.along -67.5 C-M-12 DT 6-inch wide laps spaced 54-inch o.c.; Approved Insulation Duro-Last Poly-Plates or Cleat Plates (Lim.7) fastener centered 1.25-inches from edge of tab Fastened 6-inch o.c.along Min.0.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail with -67.5 C-M-13 DL 3-inch wide tabs spaced 60-inches o.c. Approved Insulation Duro-Last Batten Bar Z (Lim.7) Tab Sealer 4725 applied at 60 ft/gal. Fastened 12-inch o.c.along Min.1.5-inch Duro-Last#14 Concrete Screw with -67.5 C-M-14 Approved Insulation DL Duro-Last Cleat Plates 6-inch wide tabs spaced 57-inches o.c. (Lim.7) Tab Sealer 4725 applied at 30 ftZ/gal. Min.0.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail with Fastened 6-inch o.c.along -82.5 C-M-15 Approved Insulation DL Duro-Last 3-inch Metal Plates 6-inch wide tabs spaced 120-inches o.c. (Lim.7) Tab Sealer 4725 applied at 60 ft/gal. Fastened 6-inch o.c.along Min. 1.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail with -97.5 C M 16 Approved Insulation DL Duro-Last Cleat Plates 6-inch wide tabs spaced 84-inches o.c. (Lim.7) Tab Sealer 4725 applied at 30 ftZ/gal. C-M-17 Min.1.5-inch DL Duro-Last#14 Concrete Screw or Fluted Concrete Nail with Fastened 6-inch o.c.along -105 Approved Insulation Duro-Last Poly-Plates or Cleat Plates 3-inch wide tabs spaced 28-inches o.c. (Lim.7) Min.0.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail with Fastened 6-inch o.c.along -105 C-M-18 Approved Insulation DL Duro-Last 3-inch Metal Plates 6-inch wide tabs spaced 57-inches o.c. (Lim.7) Tab Sealer 4725 applied at 60 ftZ/gal. Fastened 6-inch o.c.along Min.0.5-inch Duro-Last#14 Concrete Screw or Fluted Concrete Nail with -142.5 C-M-19 DL 6-inch wide tabs spaced 25-inches o.c. Approved Insulation Duro-Last Cleat Plates Tab Sealer 4725 applied at 60 ftZ/gal. (Lim.7) Assemblies with All Layers Adhered over CWF Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment , (psf) Min.1-inch DG-TF OPTIONAL DG-TF -60 CW-A-1 DF or DFP WB EPS FGF ribbon adhered 12-inch o.c. DDP,DXC,DXF, ribbon adhered 12-inch o.c. DL,DT, II, SB IV,or CR 20 (Lim.9) HD-A,HD-G,or SR DLR12001.14 FL16039-R14 Page 10 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. REEK ROOFING,INC. cREEK PVC Single-Ply Roofing Membranes AI TECHNICAL SERVICES, LLC APPENDIX B Assemblies with All Layers Adhered over CWF Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment (psf) Min. 1-inch DG-TF OPTIONAL DG-TF -90 CW-A-2 111-H ribbon adhered 12 inch o.c. DDP,DXC,DXF, ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) HD-A,HD-G,or SR OPTIONAL Min.1-inch DG-TF DG-TF -97.5 CW-A-3 EPS,11 A,11-G, ribbon adhered 12 inch o.c. DXF or SR ribbon adhered 12 inch o.c. DL,DT,DF or DFP WB II, SB IV,or CR-20 (Lim.9) I1-H,Ill-A,or 1I1-G Min.0.5-inch Duro-Grip -97.5 CW-A-4 EPS FGF,Il-A, ribbon adhered 12 inch o.c. - - DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) II-G,II-H CW-A-5 Min.0.5 inch Duro-Grip HD-G,DDP, DG-IS,DG-OB or DG-OS DL,DT,DF or DFP WB Il, SB IV,or CR-20 -97.5 1I-G ribbon adhered 12-inch o.c. EPS FGF,or SR (Lim.9) Min.0.5-inch HD-ADuro- ip ,HD-G,DDP, CW-A-6 EPS,II-A,II-G, ribbon adhered G 2-inch o.c. EPS FGF,Ill-A, DG-OB or DG-IS DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) Il-H Ill-H,IV-A,or SR Min.0.5-inch Duro-Grip Duro-Grip -97.5 CW-A-7 EPS,Il-A,II-G, ribbon adhered 12-inch o.c. DXF or DXC ribbon adhered 12 inch o.c. DL,DT, DF or DFP WB II, SB IV,or CR-20 (Lim.9) II-H OPTIONAL Min.1-inch DG-TFDG-TF -112.5 CW-A-8 EPS,IIA,II-G, ribbon adhered 12 inch o.c. HD-H ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II, SB IV,or CR-20 (Lim.9) II-H,Ill-A,or III-G Min.1-inch CW-A-9 EPS,1l A,11 G, DG TF OPTIONAL DG-TF DL,DT,DF or DFP WB II,SB IV,or CR-20 -120 II-H,111-A,or ribbon adhered 12-inch o.c. DDP,HD-G,or DXC ribbon adhered 12-inch o.c. (Lim.9) 111-G OPTIONAL Min.1-inch DG-TF DG-TF -120 CW-A-10 EPS,Il A, Il-G, ribbon adhered 12 inch o.c. HD-G ribbon adhered 12 inch o.c. DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) Il-H,Ill-A,or III-G CW-A-11 Min.1-inch DG-TF OPTIONAL DG-TF DL,DT,DF or DFP WB 11,SB IV,or CR-20 -127.5 11-H ribbon adhered 12-inch o.c. DDP or DXC ribbon adhered 12-inch o.c. (Lim.9) OPTIONAL DG-OB DG-OB or DG-OS -150 CW-A-12 EPS,11 A,11-G, ribbon adhered 12-inch o.c. DXF ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II (Lim.9) 11-H OPTIONAL DG-OB DG-OB or DG-OS ribbon -150 CW-A-13 EPS,11-A,11-G, ribbon adhered 12-inch o.c. DXF adhered 12-inch o.c. DL SB IV (Lim.9) Il-H DLR12001.14 FL16039-R14 Page 11 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. C R E E I 1 DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX B Assemblies with All Layers Adhered over CWF Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation Membrane Attachment MDP No. Insulation Attachment Insulation Attachment (psf) OPTIONAL DG-OB DG-08 or DG-OS Duro-Fleece Membrane -150 CW-A-14 EPS,11 A,11-G, ribbon adhered 12-inch o.c. DXF ribbon adhered 12-inch o.c. DF Adhesive (Lim.9) 11-H OPTIONAL DG-OB DG-OB or DG-OS -150 CW-A-15 EPS,�� II-G, ribbon adhered 12-inch o.c. DXF ribbon adhered 12-inch o.c. DFP,DF CR 20 (Lim.9) H OPTIONAL DG-OB DG-OB,DG-OS or DG-IS -150 CW-A-16 EPS,1l A,II-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II (Lim.9) /1-H OPTIONAL DG-OB DG-OB,DG-OS or DG-IS -150 CW-A-17 EPS,!I A,II-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DL SB IV (Lim.9) Il-H _ OPTIONAL DG-OB DG-OB, DG-OS or DG-IS Duro-Fleece Membrane -150 CW-A-18 EPS,Il A,11-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DF Adhesive (Lim.9) II-H _ OPTIONAL DG-OB DG-OB,DG-OS or DG-IS -150 CW-A-19 EPS,11-A,Il-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DFP or DF CR-20 (Lim.9) Il-H OPTIONALDG-TF DG-TF -165 CW-A-20 Min. 1-inch ribbon adhered 12 inch o.c. DDP ribbon adhered 12 inch o.c. DL,DT,DF or DFP W8 II, SB IV,or CR-20 (Lim.9) EPS CW-A-21 - DXC DG-TF DL,DT,DF or DFP WB II, S8 IV,or CR-20 -180 ribbon adhered 12-inch o.c. (Lim.9) OPTIONAL DG-OB DG-OB or DG-OS ribbon -180 CW-A-22 DXF DL,DT, DF or DFP WB I1 (Lim.9) iI-G ribbon adhered 12-inch o.c. adhered 12-inch o.c. OPTIONAL DG-OB DG-OB or DG-OS ribbon -180 CW-A-23 Il-G ribbon adhered 12-inch o.c. DXF adhered 12-inch o.c. DL SB IV (Lim.9) OPTIONAL DG-OB DG-OB or DG-OS ribbon Duro-Fleece Membrane -180 CW-A-24 DXF DF Il-G ribbon adhered 12-inch o.c. adhered 12-inch o.c. Adhesive (Lim.9) OPTIONAL DG-OB DG-OB or DG-OS ribbon -180 CW-A-25 DXF DFP,DF CR-20 Il-G ribbon adhered 12-inch o.c. _ adhered 12-inch o.c. (Lim.9) CW-A-26 OPTIONAL DG-OB DXC DG-OB,DG-OS or DG-IS DL,DT,DF or DFP WB 11 -205 1/-G ribbon adhered 12-inch o.c. _ ribbon adhered 12-inch o.c. (Lim.9) OPTIONAL DG-08 DG-OB,DG-OS or DG-IS -205 CW-A-27 DXC DL SB IV //-G ribbon adhered 12-inch o.c. _ ribbon adhered 12-inch o.c. (Lim.9) OPTIONAL DG-OB DG-OB,DG-OS or DG-IS Duro-Fleece Membrane -205 CW-A-28 DXC DF //-G ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. Adhesive (Lim.9) CW-A-29 OPTIONAL DG-OB DXC DG-OB,DG-OS or DG-IS DFP,DF CR-20 -205 1/-G ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) DLR12001.14 FL16039-R14 Page 12 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. CREEK PVC Single-Ply Roofing Membranes a11TECHNICAL SERVICES, LLC APPENDIX B Mechanically Fastened Assemblies over CWF Deck(New,Existing,or Recover) System Insulation Membrane Fasteners Attachment MDP No. (psf) -30 CW-M-1 - DL Duro-Last Auger Fasteners and Auger Plates Attached 6-inch o.c.within 3-inch tabs (Lim.7; spaced 60-inch o.c. Non- HVHZ) -37.5 CW-M-2 - DL Duro Last Auger Fasteners and Auger Plates Attached 6-inch o.c.along 3-inch tabs spaced 60-inch o.c. (Lim.7; with Dow ENERFOAM Non- HVHZ) CW-M-3 Min.0.5-inch DL Duro-Last Auger Fasteners and Auger Plates Attached 6-inch o.c.along 6-inch tabs spaced 57-inch o.c. -45Approved Insulation (Lim.7) CW-M-4 Min.0.5-inch DL Duro-Last Auger Fasteners and Auger Plates Attached 6-inch o.c.along 6-inch tabs spaced 57-inch o.c. -52.5 Approved Insulation Tab Sealer 4725 applied at 60 ft/gal. (Lim.7) Fastened through the membrane 6-inch o.c. CW-M-5 DT or DL Duro-Last Auger Fasteners and Auger Plates in rows spaced 60-inch o.c.; -67.5 with Dow ENERFOAMT" 10-inch wide membrane welded over fastener rows (Lim.7 with 1.5-inch wide heat weld. Fastened through the membrane 6-inch o.c. CW-M-6 DT or DL Duro-Last Auger Fasteners and Auger Plates in rows spaced 96-inch o.c.; -67.5 with Dow ENERFOAMr" 10-inch wide membrane welded over fastener rows (Lim.7 with 1.5-inch wide heat weld. Assemblies with All Layers Adhered over Gypsum Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment (psf) Min.1-inch DG-TF OPTIONAL DG-TF -60 G-A-1 EPS FGF ribbon adhered 12-inch o.c. DDP,DXC,DXF, ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB Il, SB/V,or CR-20 (Lim.9) HD-A,HD-G,or SR Min.0.5 inch Duro-Grip -82.5 G-A-2 EPS FGF,Il-A, ribbon adhered 12-inch o.c. - - DL,DT,DF or DFP WB Ilor SB IV (Lim.9) ll-G,Il-H Min.0.5-inch Duro-Grip HD-G,DDP, DuroGrip -82.5 G-A-3 11-G ribbon adhered 12 inch o.c. EPS FGF, or SR ribbon adhered 12-inch DL,DT,DF or DFP WB ll,SB IV,or CR-20 (Lim.9) o.c. Min.0.5 inch Duro-Grip HD-A,HD-G,DDP, DG-OB or DG-IS -82.5 G-A-4 EPS,11-A,II-G, DF or DFP WB ribbon adhered 12-inch o.c. EPS FGF,Ill-A, ribbon adhered 12-inch o.c DL,DT, II, SB IV,or CR-20 (Lim.9) II-H Ill-H,IV-A,or SR Min.0.5-inch Duro-Grip Duro-Grip -82.5 G-A-5 EPS,��A,II-G, ribbon adhered 12 inch o.c. DXF or DXC ribbon adhered 12 inch o.c. DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) Min.1-inch DG-TF OPTIONAL DG-TF -90 G-A-6 DL Ill-H ribbon adhered 12-inch o.c. DDP,DXC,DXF, ribbon adhered 12-inch o.c. ,DT,DF or DFP WB Il,SB IV,or CR-20 (Lim.9) HD-A,HD-G,or SR DLR12001.14 FL16039-R14 Page 13 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. ti DURO-LAST ROOFING,INC. CREEK PVC Single-Ply Roofing Membranes AM TECHNICAL SERVICES, LLC APPENDIX B Assemblies with All Layers Adhered over Gypsum DeckfNew or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment (psf) OPTIONAL Min. 1-inch DG-TF DG-TF -97.5 G-A-7 EPS,11-A,11-G, ribbon adhered 12 inch o.c. DXF or SR ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB Il,SB IV,or CR-20 (Lim.9) II-H,Ill-A,or 111-G G-A-8 - - - - DF or DFP CR-20 -105 (Lim.9) OPTIONAL Min.1-inch DG-TF DG-TF -112.5 G-A-9 EPS,IIA,II-G, ribbon adhered 12-inch o.c. HD-H ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) Il-H,Ill-A,or Ill-G _ Min.1-inch OPTIONAL G-A-10 EPS,11 A,l!-G, DG-TF DDP,HD-G,or DG-TF DL,DT,DF or DFP WB II,SB IV,or CR-20 -120 Il-H,Ill-A,or ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. (Lim.9) 111-G OPTIONAL Min.1-inch DG-TF DG-TF -120 G-A 11 EPS,1l A,11-G, ribbon adhered 12-inch o.c. HD-G ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) Il-H,Ill A,or 111-G • G-A-12 Min.1-inch DG-TF OPTIONAL DG-TF DL,DT,DF or DFP WB Il,SB IV,or CR-20 -127.5 Il-H ribbon adhered 12-inch o.c. DDP or DXC ribbon adhered 12-inch o.c. (Lim.9) OPTIONAL DG-TF DG-TF -165 G-A-13 Min.1-inch ribbon adhered 12 inch o.c. DDP ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) EPS G-A-14 - DXC ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim. OPTIONAL DG-OB DG-OB or DG-OS -180 G-A-15 EPS,11-A,11-G, ribbon adhered 12-inch o.c. DXF ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB 11 (Lim.9) Il-H OPTIONAL DG-OB DG-OB or DG-OS -180 G-A-16 EPS,11-A,11-G, ribbon adhered 12-inch o.c. DXF ribbon adhered 12-inch o.c. DL SB IV (Lim.9) ll-H _ OPTIONAL DG-OB DG-OB or DG-OS ribbon Duro-Fleece Membrane -180 G-A-17 EPS,11-A,Il-G, ribbon adhered 12-inch o.c. DXF adhered 12-inch o.c. DF Adhesive (Lim.9) ll-H OPTIONAL DG-OB DG-OB or DG-OS ribbon -180 G-A-18 EPS,11 A,11-G, ribbon adhered 12-inch o.c. DXF adhered 12-inch o.c. DF or DFP CR-20 (Lim.9) ll-H OPTIONAL DG-OB DG-OB,DG-OS or DG-IS -180 G A-19 EPS,11-A,11-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DL,DT,DF or DFP WB II (Lim.9) ll-H DLR12001.14 FL16039-R14 Page 14 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. \ CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX B Assemblies with All Layers Adhered over Gypsum Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Insulation Attachment Insulation Attachment Membrane Attachment (psi) OPTIONAL DG-OB DG-OB,DG-OS or DG-1S -180 G-A-20 EPS,11-A,11-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DL SB IV (Lim.9) 11-H OPTIONAL DG-OB DG-OB,DG-OS or DG-IS Duro-Fleece Membrane -180 G-A-21 EPS,11 A,11-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DF Adhesive (Lim.9) Il-H OPTIONAL DG-OB DG-OB,DG-OS or DG-IS -180 G-A-22 EPS,11 A,11-G, ribbon adhered 12-inch o.c. DXC ribbon adhered 12-inch o.c. DF or DFP CR 20 (Lim.9) Il-H G-A-23 OPTIONAL DG-OS DXF DG-OB or DG-OS DL,DT,DF or DFP WB 11 -195 EPS,IIA,11-H ribbon adhered 12-inch o.c. _ ribbon adhered 12-inch o.c. (Lim.9) G-A-24 OPTIONAL DG-OS DXF DG-OB or DG-OS DL SB IV -195 EPS,Il-A,Il-H ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) G-A-25 OPTIONAL DG-OS DXF DG-OB or DG-OS DF Duro-Fleece Membrane -195 EPS,11-A, I1-H ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. _ Adhesive (Lim.9) G-A-26 OPTIONAL DG-OS DXF DG-OB or DG-OS DF or DFP CR-20 -195 EPS,Il-A, 11-H ribbon adhered 12-inch o.c. _ ribbon adhered 12-inch o.c. (Lim.9) G-A-27 OPTIONAL DG-OS DXC DG-OB,DG-OS or DG-IS DL,DT,DF or DFP WB 11 -195 EPS,IIA, I1-H ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) G-A-28 OPTIONAL DG-OS DXC DG-OB,DG-OS or DG-IS DL SB IV -195 EPS,11 A, ll-H ribbon adhered 12-inch o.c. , ribbon adhered 12-inch o.c. (Lim.9) G A-29 OPTIONAL DG-OS DXC DG-OB,DG-OS or DG-IS DF Duro-Fleece Membrane -195 EPS,1l A, 11-H ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. Adhesive (Lim.9) G-A-30 OPTIONAL DG-OS DXC DG-OB,DG-OS or DG-IS DF or DFP CR-20 -195 EPS,11 A, Il-H ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) G-A 31 OPTIONAL DG-OB DXC DG-OB,DG-OS or DG-IS DL,DT,DF or DFP WB 11 -217.5 II-A ribbon adhered 12-inch o.c. ribbon adhered 12-inch o.c. (Lim.9) G A-32 OPTIONAL DG-OB DXC DG-OB,DG-OS or DG-1S DL SB/V -217.5 II-A ribbon adhered 12-inch o.c. _ ribbon adhered 12-inch o.c. (Lim.9) G-A-33 OPTIONAL DG-OB DXC DG-OB,DG-OS or DG-IS DF Duro-Fleece Membrane -217.5 li-A ribbon adhered 12-inch o.c. . ribbon adhered 12-inch o.c. Adhesive (Lim.9) G-A-34 OPTIONAL DG-OB DXC DG-OB,DG-OS or DG-IS DF or DFP CR-20 -217.5 Il-A _ ribbon adhered 12-inch o.c. _ ribbon adhered 12-inch o.c. (Lim.9) Mechanically Fastened Assemblies over Poured Gypsum Deck(New or Existing) System Insulation Membrane Fasteners Attachment MDP No. (psf) Fastened through the membrane 6-inch o.c.in rows -30 G-M-1 - DT Min. 1.8-inch TRUFAST Twin Loc-Nail Assembled Fastener spaced 60-inch o.c.; 10-inch wide cover strip welded (Lim.7; over fastener rows with 1.5-inch wide heat weld. Non- HVHZ) DLR12001.14 FL16039-R14 Page 15 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. GREEK DURO-LAST ROOFING,INC. PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX B Mechanically Fastened Assemblies over Poured Gypsum Deck(New or Existing) System Insulation Membrane Fasteners Attachment MDP No. (psf) -37.5 G-M-2 Duro-Guard DL Min.3-inch Duro-Last Auger Fasteners and Auger Plates Fastened 6-inch o.c.along 3-wide tabs (Lim.7; EPS Fan Fold spaced 60-inch o.c. Non- HVHZ) Min.2.5-inch Duro-Last Auger Fasteners and Auger Plates Fastened through the membrane 6-inch o.c.in rows -45 G-M-3 - DT or DL or TRUFAST Twin Loc Coiled Batten Bar and spaced 48-inch o.c.; 10-inch wide cover strip welded (Lim.7) min.1.8-inch TRUFAST Twin Loc-Nail Batten Fastener over fastener rows with 1.5-inch wide heat weld. Fastened through the membrane 6-inch o.c.in rows -60 G-M-4 - DT or DL Min. 1.8-inch TRUFAST Twin Loc-Nail Assembled Fastener spaced 48-inch o.c.; 10-inch wide cover strip welded (Lim.7) over fastener rows with 1.5-inch wide heat weld. Fastened through the membrane 3-inch o.c.in rows G-M-5 - DT or DL TRUFAST Twin Loc Coiled Batten Bar and spaced 48-inch o.c.;10-inch wide cover strip welded -82'5 min.1.8-inch TRUFAST Twin Loc-Nail Batten Fastener (Lim.7) over fastener rows with 1.5-inch wide heat weld. Adhered Lightweight Insulating Concrete Assemblies over Concrete Deck(New or Existing) System LWIC Membrane Membrane Attachment MDP No. , (Psf) -45 LC-A-1 Min.300 psi Celcore MF with HS Rheology Admixture DL,DT,DF or DFP WB 11,SB IV,or CR-20 (Lim.9) LC-A-2 Min.330 psi LWIC DL,DT,DF or DFP WB Il,SB IV,or CR-20 -45(MCRF 2 185 lbf using Duro-Last Auger Fasteners) (Lim.9) -62.5 LC-A-3 Min. 160 psi LW/C DF or DFP CR-20 (Lim.9 HVHZ only) LC-A-4 Min.270 psi Elastizell with Zell-Crete Fibers DL or DT WB II -75 (Lim.9) LC-A-5 Min.340 psi Celcore MF with HS Rheology Admixture DL,DT,DF or DFP WB II,SB IV,or CR-20 -82.5 above Celcore S-1 (Lim.9) LC-A-6 Min.390 psi Celcore MF with HS Rheology Admixture DL,DT,DF or DFP WB II,SB IV,or CR-20 -90 above Celcore S-1. (Lim.9) LC-A-7 Min.270 psi Elastizell with Zell-Crete Fibers DL or DT S8 IV -90 (Lim.9) -137.5 LC-A-8 Min.250 psi Elastizell with Zell-Crete Fibers DF or DFP CR-20 (Lim.9 and topped with Zell-erator tor Sealer HVHZ only) -162.5 LC-A-9 Min.300 psi Celcore MF with HS Rheology Admixture DF or DFP CR-20 (Lim.9 topped with Celcore PVA curing compound HVHZ only) DLR12001.14 FL16039-R14 Page 16 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. ,,;s CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX B Adhered Lightweight Insulating Concrete Assemblies over Concrete Deck(New or Existing) System LWIC Membrane Membrane Attachment MDP No. (psf) LC-A-10 Min.300 psi Celcore MF with HS Rheology Admixture DL,DT,DF or DFP WB/l -285 topped with Celcore PVA curing compound (Lim.9) Min.200 psi LWIC 457.5 LC-A-11 (MCRF 2 60 Ibf using TRUFAST FM-90 Base Sheet DL,DT,DF or DFP WB/l (Lim.9) Fastener) LC-A-12 Min.200 psi Elastizell with Zell-Crete Fibers DL, DT,DF or DFP WB II -485 _ (Lim.9) Mechanically Attached Lightweight Insulating Concrete Assemblies over Concrete Deck(New or Existing) System LWIC Membrane Membrane Attachment MDP No. (psf) Duro-Last Auger Fasteners and Auger Plates -37.5 LC-M-1 Min.330 LWIC DT or DL attached 6-inch o.c.in rows spaced 60 in.o.c. (Lim.7; (MCRF 2 185 Ibf using Duro-Last Auger Fasteners) and encapsulated with 6-inch wide cover strip of DL Non- HVHZ) TRUFAST Twin Loc Coiled Batten Bar and LC-M-2 Min.360 LW/C DT or DL min. 1.8"TRUFAST Twin Loc-Nail Batten Fastener -45 (MCRF 2 91 Ibf using TRUFAST Twin Loc-Nail Batten Fastener) attached 3-inch o.c.in rows spaced 48-inch o.c.and (Lim.7) encapsulated with 6-inch wide cover strip of DL Adhered Lightweight Insulating Concrete Assemblies over Steel Deck(New or Existing) System Deck Detail LW/C Membrane Membrane Attachment MDP No. (psf) LS-A-1 G33,L5,P,S15 Min.300 psi Celcore MF with HS Rheology Admixture DL,DT,DF or DFP WB Il,SB IV,or CR-20 -45 (Lim.9) LS-A-2 Min.26 ga.HD-Dek, Min.360 psi LW/C DL,DT,DF or DFP WB II,SB IV,or CR-20 -45Vented, G80,L5,P,S15 (MCRF 2 91 Ibf using TRUFAST Twin Loc-Nail Batten Fastener) (Lim.9) LS-A-3 G33,L6,P,S18 Min.340 psi Celcore MF with HS Rheology Admixture DL,DT,DF or DFP WB II,SB IV,or CR-20 -82.5 above Celcore S-1 (Lim.9) LS-A-4 G33,L5,P,S18 Min.390 psi Celcore MF with HS Rheology Admixture DL,DT,DF or DFP WB II,SB IV,or CR-20 -90 above Celcore S-1. (Lim.9) Min.330 psi Celcore MF with HS Rheology Admixture; Secure lightweight with OMG HD Batten Bars or -97.5 LS-A-5 G33,L5,F1,S15 OMG Polymer Batten Strips oriented with the length of the bar DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim.9) perpendicular to the deck flutes and spaced 18-inch o.c.; Secure battens with OMG XHD fastened 12-inch o.c. -175 LC-A-6 G33,L5 Min.160 psi LWIC DF or DFP CR-20 (Lim'9 HVHZ only) DLR12001.14 FL16039-R14 Page 17 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DURO-LAST ROOFING,INC. Single-Ply4 Roofing Membranes 111111 TECHNICAL SERVICES, LLC PVC APPENDIX B Adhered Lightweight Insulating Concrete Assemblies over Steel Deck(New or Existing) System Deck Detail LWIC Membrane Membrane Attachment No. MDP . (psi -295 LC-A-7 G33,L5 Min.250 psi Elastizell with Zell-Crete Fibers DF or DFP CR-20 (Lim.9 and topped with Zeli-erator tor Sealer HVHZ only.) Mechanically Attached Lightweight Insulating Concrete Assemblies over Steel Deck(New or Existing) System Deck Detail LWIC Membrane Membrane Attachment MDP No. (psf) Duro-Last Auger Fasteners and Auger Plates -37.5LS-M-1 Min.26 ga.HD-Dek,Vented, Min.330 LWIC DT or DL attached 6-inch o.c.in rows spaced 60 in.o.c.and (Llm.7; G80,L5,P,S15 (MCRF i'185 lbf using Duro-Last Auger Fasteners) encapsulated with 6-inch wide cover strip of DL Non- HVHZ) Min.360 LWIC TRUFAST Twin Loc Coiled Batten Bar and -45 Min.26 ga.HD-Dek,Vented, min. 1.8"TRUFAST Twin Loc-Nail Batten Fastener (Lim.7; LS-M-2 G80, L5,P,S15 (MCRF z 91 lbf using TRUFAST Twin Loc-Nail DT or DL attached 3-inch o.c.in rows spaced 48-inch o.c. Non- Batten Fastener) and encapsulated with 6-inch wide cover strip of DL HVHZ) Adhered Recover Assemblies System Existing Roof Insulation Insulation Attachment Membrane Membrane MDP No. Attachment (psf) Steel Deck Duro-Last#14 HD Fastener and -67.5 R-A-1 (G33,L6,Fl,S24) DDP or SR Duro-Last 3-inch Metal Plates DL,DT,DF or DFP WB II,SB IV,or CR-20 (Lim 7) fastened at a rate of 24 per 4 ft x 8 ft board Steel Deck Min.0.5 inch TRUFAST DP#12 Fasteners and -82.5 R-A-2 (G33,L6,F1,S24) SR TRUFAST 3"Metal Insulation Plates DL,DT,DF or DFP SB IV or WB II (Lim.7) fastened at a rate of 32 per 4 ft x 8 ft board Smooth or Granule Surfaced BUR, Granule Surfaced SBS or - - DF CR-20 -120 R-A-3 Granule Surfaced APP Cap Sheet. (Lim.9) Subcomponents adhered Granule Surfaced BUR,SBS or -150 R-A-4 APP Cap Sheet. - - DFP CR-20 Lim.9 Subcomponents mechanically attached. ( ) Smooth or Granule Surfaced BUR, R-A-5 Granule Surfaced SBS or DFP CR-20 -370 Granule Surfaced APP Cap Sheet. (Lim.9) Subcomponents adhered. DLR12001.14 FL16039-R14 Page 18 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. ,. CREEK PVC Single-Ply LAST ROOFING,INC. Roofing Membranes j. TECHNICAL SERVICES. LLC APPENDIX B Mechanically Fastened Recover Assemblies System Existing Roof Insulation Insulation Membrane Membrane Attachment MDP No. Attachment (psf) Duro-Last Auger Fasteners and Auger Plates fastened -30 CWF Deck or through the membrane 6-inch o.c.in rows spaced 48-inch o.c.; (Lim.7; R-M-1 - -Gypsum Deck DL 10-inch wide membrane welded over fastener rows Non- with 1.5-inch wide heat weld. HVHZ) Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -37.5 Steel Deck OPTIONAL Preliminarily (Lim.7; R-M-2 within (G33,L6,P,S24) Approved Insulation secured DT Cleat Plates fastened 12 inch o.c. Non- 6-inch wide laps spaced 114-inch o.c. HVHZ) Duro-Last Auger Fasteners(min.2.5-inch penetration into substrate)and Auger Plates or R M 3 Poured Gypsum DT or DL TRUFAST Twin Loc Coiled Batten Bar and TRUFAST Twin Loc- -45 Nail Batten Fastener fastened through the membrane (Lim.7) 6-inch o.c.in rows spaced 48-inch o.c.; 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-4 Steel Deck -45- - DT Cleat Plates fastened 12-inch o.c.within (G33, L6,Fl,S24) (Lim.7) 6-inch wide laps spaced 114-inch o.c. Min.24 ga.R-Panel or Approved Insulation PBR panel metal roofing at filled between ribs. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and max.5ft span and fastened Preliminarily -45 R-M-5 Mn.i0.5-inch DL Duro-Last Cleat Plates or Poly-Plates fastened 12 inch o.c.at each support Approved Insulation secured 6-inch o.c.within 3-inch wide tabs spaced 60-inch o.c. (Lim.7) with min.#12 HWH screws above ribs with min.0.5-inch washers Steel Deck OPTIONAL Preliminarily Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -45 R-M-6 DL Poly-Plates or Cleat Plates fastened 6-inch o.c. (G33,16,Fl,SO) Approved Insulation secured along 6-inch wide tabs spaced 120-inch o.c. (Lim.7) Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-7 Steel Deck OPTIONAL Preliminarily DT Cleat Plates fastened 12-inch o.c.within -45(G33,L6,Fl,S24) Approved Insulation secured (120-inch wide) (Lim.7) 4-inch wide laps spaced 116 inch o.c. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and Wood Deck Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c.within -45 R-M 8 (T19/32,L24,0.113-6/6) DT 6-inch wide laps spaced 114-inch o.c.; (Lim.7) fastener centered 1.25-inches from edge of tab Duro-Last#15 Extra Heavy Duty Drill Point Fastener and Steel Deck Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. -45 R-M-9 - -(G33,L6,PW or Fl,S24) DT within 6-inch wide laps spaced 114-inch o.c.; (Lim.7) fastener centered 1.25-inches from edge of tab Min.225 psi LWIC over Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-10 Steel Deck - - DL Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c.within -45 (Min.26 ga.HD-Dek, (Lim.7) 3-inch wide tabs spaced 60-inch o.c. Vented, G80,L5,P,S15) DLR12001.14 FL16039-R14 Page 19 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. ^1 CREEK PVC DURO-LAST ROOFING,INC. Single-Ply Roofingg Membranes ranes TECHNICAL SERVICES, LLC APPENDIX B Mechanically Fastened Recover Assemblies System Existing Roof Insulation Insulation Membrane Membrane Attachment MDP No. Attachment (psf) Min.26 ga.R-Panel or Approved Insulation PBR panel metal roofing at filled between ribs. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and Preliminarily 45 R-M-11 max.5ft span and fastened Min.0.5-inch DT Duro-Last Poly-Plates fastened 6-inch o.c. (Lim.7) 6-inch o.c.at each su ort Approvedsecured pp Insulation within 6-inch wide laps spaced 54-inch o.c with min.#12 HWH screws above ribs Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-12 Steel Deck DT Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c.within -52.5 (G33,L6,PW,S24) 6-inch wide laps spaced 54-inch o.c.; (Lim.7) fastener centered 1.25-inches from edge of tab Steel Deck OPTIONAL Preliminarily Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -52.5 R-M-13 (G33,L6,PW,SO) Approved Insulation secured DL Poly-Plates or Cleat Plates fastened 6-inch o.c. (Lim.7) along the 3-inch wide tabs spaced 60-inch o.c. Wood Deck OPTIONAL Preliminarily Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -52.5 R-M-14 ApprovedDL Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c.along (T19/32,L24,0.113-6/6) Insulation secured (Lim.7)wide tabs spaced 60-inch o.c. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-15 Wood Deck OPTIONAL Preliminarily DL Duro-Last Cleat Plates fastened 6-inch o.c. -52.5 (T19/32,L24,8d-6/6) Approved Insulation secured along 6-inch wide tabs spaced 57-inch o.c. (Lim.7) (Screws located 2.7-inches from tab edge) Wood Deck OPTIONAL Preliminarily Duro-Last#14 HD Fastener and Duro-Last 3-inch Metal Plates -52.5 R-M-16 (T19/32,L24,8d 6/6) Approved Insulation secured DL fastened 6-inch o.c.along 6-inch wide tabs spaced 57-inch o.c. (Lim.7) Tab Sealer 4725 applied at 60 ft2/gal. Min.24 ga.R-Panel or Approved Insulation PBR panel metal roofing at filled between ribs. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and max.5ft span and fastened Preliminarily -52.5 R-M-17 Min.0.5-inch DL Duro-Last Cleat Plates or Poly-Plates fastened 12-inch o.c. ( 12-inch o.c.at each support secured Lim.7) with min.#12 HWH screws Approved Insulation along 3-inch wide tabs spaced 28-inch o.c. with min.0.5-inch washers above ribs Min.26 ga.R-Panel or Approved Insulation PBR panel metal roofing at filled between ribs. Preliminarily Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -52.5 R-M-18 max.5ft span and fastened Min.0.5-inch secured DT Duro-Last Poly-Plates fastened 12-inch o.c. (Lim.7) 6-inch o.c.at each support Approved Insulation within 6-inch wide laps spaced 24-inch o.c with min.#12 HWH screws above ribs Wood Deck OPTIONAL Preliminarily Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -60 R-M-19 (T19/32,L24, 0.113 6/6) Approved Insulation secured DL Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c.along •(Lim.7) 6-inch wide tabs spaced 120-inch o.c. Wood Deck Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -60 R-M-20 (T15/32,L24,0.113-6/6) - DT Duro-Last Poly-Plates or Cleat Plates fastened (Lim.7) 6-inch o.c.within 6-inch wide laps in rows spaced 24-inch o.c Wood Deck Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -60 R-M-21 (T15/32,L24,0.113-6/6) - - DL Duro-Last Poly-Plates or Cleat Plates fastened (Lim.7) 6-inch o.c.along 3-inch wide tabs spaced 28-inch o.c. DLR12001.14 FL16039-R14 Page 20 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. 4-- CREEK PVC Single-Ply Roofing Membranes IN TECHNICAL SERVICES. LLC APPENDIX B Mechanically Fastened Recover Assemblies System Existing Roof Insulation Insulation Membrane Membrane Attachment MDP No. Attachment (psf) Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-22 Steel Deck DT Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c.within -67.5 - -(G33,L6,Fl,S24) 6-inch wide laps spaced 54-inch o.c.; (Lim.7) fastener centered 1.25-inches from edge of tab Duro-Last Auger Fasteners and Auger Plates with Dow ENERFOAMN fastened through the membrane -67.5 R-M-23 CWF Deck - - DT or DL 6-inch o.c.in rows spaced 60-inch o.c.; (Lim.7 10-inch wide membrane welded over fastener rows with 1.5-inch wide heat weld. Duro-Last Auger Fasteners and Auger Plates with Dow ENERFOAMN fastened through the membrane -67.5 R-M-24 CWF Deck - - DT or DL 6-inch o.c.in rows spaced 96-inch o.c.; (Lim.7 10-inch wide membrane welded over fastener rows with 1.5-inch wide heat weld. TRUFAST Twin Loc Coiled Batten Bar and TRUFAST Twin Loc-Nail Batten Fastener R-M-25 Gypsum Deck OT or DL fastened through the membrane 3-inch o.c. -82.5 in rows spaced 48-inch o.c.; (Lim.7) 10-inch wide cover strip welded over fastener rows with 1.5-inch wide heat weld. Min.24 ga.R-Panel or PBR panel metal roofing at Approved Insulation max.5ft span and fastened filled between ribs. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-26 12-inch o.c.at each supportPreliminarily -82.5 Min. 1-inch secured DL Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. (Lim.7) with min.(2)#12 HWH Approved Insulation along 3-inch wide tabs spaced 28-inch o.c. screws with min.0.5-inch above ribs OD washers per rib Duro-Last#14 Concrete Screw or R-M-27 Concrete Deck OPTIONAL Preliminarily DL Fluted Concrete Nail with Duro-Last 3-inch Metal Plates -82.5 Approved Insulation secured fastened 6-inch o.c.along 6-inch wide tabs spaced 120-inch o.c. (Lim.7) Tab Sealer 4725 applied at 60 ft2/gal. Induction Welded Recover Assemblies System Existing Roof Weld Plate Weld Plate Attachment Membrane Membrane Attachment MDP No. (psf) Steel Deck OMG XHD Fastener with Secured at a rate of 1 per 4.00-ft2 -52.5 R-W-1 plate (G33,L6,Fl,S24) Duro-Bond Plate 1302 or DL or DT Induction welded to each insulation Duro-Bond PVC IW Plate (See Appendix A-Induction Weld Patterns) (Lim.7) Steel Deck OMG XHD Fastener with Secured at a rate of 1 per 4.00-ft2 -52.5 R-W-2 (G33,L6,P.S24) Duro-Bond Plate 1302 or (See Appendix A-Induction Weld Patterns) DL or DT Induction welded to each insulation plate (Lim.7) Duro-Bond PVC IW Plate DLR12001.14 FL16039-R14 Page 21 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. 4 CREEKPVC Singe-Ply Roofing Membranes IN TECHNICAL SERVICES. LLC APPENDIX B Assemblies with All Layers Adhered over Steel Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Deck Detail Insulation Attachment Insulation Attachment ` Membrane Attachment (psf) Min. 1.5-inch EPS FGF,I1-A,ll-G, -37.5 S-A-1 G33,L6,Fl,S24 OPTIONAL Duro-Grip III-A,Ill-H,IV-A; Duro-Grip DL or DT WB 11 or SB IV (Lim.9; Duro-Guard II ribbon adhered 6-inch o.c or HD-G,HD-G, ribbon adhered 6-inch o.c. Non- HD-A,DDP,SR, HVHZ) DXF or DXC Min. 1.5-inch EPS FGF, Il-A, II-G, -37.5 S-A-2 G33,L6,Fl,S24 OPTIONAL Duro-Grip or DG-TF III-A,Ill-H,IV-A; Duro-Grip or DG-TF DF or DFP WB I/or CR-20 (Lim.9; Duro-Guard II ribbon adhered 6-inch o.c or HD-G,HD-G, ribbon adhered 6-inch o.c. Non- HD-A,DDP, SR, HVHZ) DXF or DXC Min. 1.5-inch EPS FGF, Il-A,I1-G, S-A-3 G33,L6,P, S24 OPTIONAL Duro-Grip or DG-TF III-A,111-H, IV-A; Duro-Grip or DG-TF DL or DT WB II or SB IV -60 Duro-Guard 11 ribbon adhered 6-inch o.c or HD-G,HD-G, ribbon adhered 6-inch o.c (Lim.9) HD-A, DDP, SR, DXF or DXC Min.1.5-inch EPS FGF, II-A,II-G, S-A-4 G33,L6,P, S24 OPTIONAL Duro-Grip or DG-TF Ill-A,Ill-H, IV-A; Duro-Grip or DG TF DF or DFP WB Il or CR-20 -60 Duro-Guard II ribbon adhered 6-inch o.c or HD-G,HD-G, ribbon adhered 6-inch o.c (Lim.9) HD-A,DDP,SR, DXF or DXC Min.0.5-inch Duro-Grip DL,DT,DF WB II, SB IV or -82.5 S-A-5 G33,L5 EPS FGF, ribbon adhered - - or DFP CR-20 (Lim.9) 11-A,II-G,Il-H 12-inch o.c. Duro-Gnp HD-G,DDP,DXC, Duro-Grip Min.0.5-inch DL, DT,DF WB II, SB IV or -82.5 S-A-6 G33,L5 ribbon adhered DXF, EPS FGF,or ribbon adhered //-G 12-inch o.c. SR _ 12-inch o.c. or DFP CR-20 (Lim.9) HD-A,HD-G,DDP, Min.0.5-inch Duro-Grip DG-OB or DG-/S DXC,DXF, EPS DL, DT,DF WB ll,SB IV or -82.5 S-A-7 G33,L5 EPS,I1 A, ribbon adhered ribbon adhered 11-G,11-H 12-inch o.c. FGF,III-A,Il/-H, IV- 12-inch o.c. or DFP CR-20 (Lim.9) A,or SR _ _ Min.1-inch OPTIONAL DG-TF (except over EPS) DG-TF EPS,Il-A, DL, DT,DF WB ll, SB IV or -90 S-A-8 G33,L5 ribbon adhered 12-inch HD-A,HD-G,HD-H, ribbon adhered 12-inch I1-G,I1-H,Ill-A, o.c. DDP,DXC,DXF,or o.c. or DFP CR-20 (Lim.9) 111-G,or Ill-H SR Min.1.5-inch DG-OS ribbon adhered DL,DT,DF WB ll, SB IV or -90 S-A-9 G33, L6,P,S24 II-H,Il/-H,or 6-inch o.c.to the top flange or DFP CR-20 (Lim.9) /I-G of each deck rib DLR12001.14 FL16039-R14 Page 22 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING, INC. 4 CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX B Assemblies with All Layers Adhered over Steel Deck(New or Existing) System Base Layer Base Insulation Top Layer Top Insulation MDP No. Deck Detail Insulation Attachment Insulation Attachment Membrane Attachment (psf) Min. 1.5-inch DG-OS ribbon adhered EPS, DXC,DXF,HD-H, DG-OS ribbon adhered DL,DT,DF WB II,SB IV or -97.5 S-A-10 G33,L6,Fl,S24 EPS FGF, 6-inch o.c.to the top flange EPS FGF,or SR 6-inch o.c. or DFP CR-20 (Lim.9) !1-H,or 111-H of each deck rib DG-OS ribbon adhered Min. 1.5-inch DDP,DXC,DXF, DG-OS ribbon adhered DL,DT,DF WB II, SB IV or -97.5 S-A-11 G33,L6,Fl,S24 11 G 6-inch o.c.to the top flange HD-G,or SR 6-inch o.c. or DFP CR-20 (Lim.9) of each deck rib Min.1.5 inch DG-OS ribbon adhered EPS, DXC,DXF,HD-H, DG-OS ribbon adhered DL,DT,DF WB 11,SB IV or -112.5 S-A-12 G33,L6,P, S24 EPS FGF, 6-inch o.c.to the top flange EPS FGF,or SR 6-inch o.c. or DFP CR-20 (Lim.9) 11-H or 111-H of each deck rib Min. 1.5-inch DG-OS ribbon adhered DL,DT,DF WB 11,SB IV or -135 S-A-13 G33,L6,Fl,S24 EPS FGF, 6-inch o.c.to the top flange - or DFP CR-20 (Lim.9) 11-H or Ill-H of each deck rib Assemblies with Adhered Membranes over Steel Deck(New, Existing,or Recover) System Deck Base Layer Base Layer Top Layer MDP No. Detail Insulation Attachment Insulation Top Insulation Attachment Membrane Attachment (psf) Min. 1.5-inch Simultaneously JM Invinsa Duro-Last 3-inch Metal Plates with -45 S-AM-1 G33,L5 Approved Insulation secured with top layer Roof Board Duro-Last Duro-Coated Hex Head Screws DL SB IV (Lim.9) secured at a rate of 16 per 4 ft x 8 ft board Min.1.5-inch OPTIONAL Simultaneously 11-A,11-G, Ill-A, Duro-Last 3-inch Metal Plates with DL,DT,OF WB II,SB IV -45 S-AM-2 G33, L5 A roved Insulation secured with topla er Ill-H,IV-A or Duro-Last Duro-Coated Hex Head Screws or DFP or CR 20 Lim. pp y Min.0.5-inch secured at a rate of 16 per 4 ft x 8 ft board ( 9) SR DL Plates& S-AM-3 G33, L5 Min. 1.5-inch #15 Fasteners Min.0.25-inch Duro-Fleece Membrane Adhesive DL,DT,OF WB II,SB IV -45 Approved Insulation secured at a rate of DD or ll-A ribbons spaced 6-inch o.c. or DFP or CR-20 (Urn.9) 16 per4ftx8ftboard Min.1.5-inch II-A,ll-G, 11-H,Ill-A; S-AM-4 G33, L5 OPTIONAL Simultaneously Min.2-inch DL Plates&#15 Fasteners DL,DT,DF WB II, SB IV -45 Approved Insulation secured with top layer 1V-A;or secured at a rate of 16 per 4 ft x 8 ft board or DFP or CR-20 (Urn.9) Min.0.5-inch SR or DDP S-AM-5 G33,L5 OPTIONAL Simultaneously SR or DDP DL Plates&#15 Fasteners DL,DT,DF WB II,SB IV -45 Approved Insulation secured with top layer secured at a rate of 16 per 4 ft x 8 ft board or DFP or CR-20 (Lim.9) OPTIONAL Simultaneously Min.0.5-inch TRUFAST DP#12 Fasteners and DL,DT,DF -45 S-AM-6 G33,L5 Approved Insulation secured with top layer DXF TRUFAST 3"Metal Insulation Plates z or DFP WB II (Lim.9) secured at a rate of 1 fastener per 4 ft DLR12001.14 FL16039-R14 Page 23 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. ^ �+ DURO-LAST ROOFING,INC. CREEK PVC Single-Ply Roofing Membranes `* TECHNICAL SERVICES. LLC APPENDIX B Assemblies with Adhered Membranes over Steel Deck(New, Existing,or Recover) System Deck Base Layer Base Layer Top Layer Top Insulation Attachment Membrane Attachment MDP No. Detail Insulation Attachment Insulation (psf) OPTIONAL Simultaneously Min.0.5-inch TRUFAST DP#12 Fasteners and -45 S-AM-7 G33,L5 Approved Insulation secured with topTRUFAST 3"Metal Insulation Plates DL SB IV pp layer DXF secured at a rate of 1 fastener per 4 ft2 (Lim.9) OPTIONAL Simultaneously Min.0.5-inch TRUFAST DP#12 Fasteners and Duro-Fleece -45 S-AM-B G33,L5 TRUFAST 3"Metal Insulation Plates DF Membrane ( 9) Approved Insulation secured with top layer DXF secured at a rate of 1 fastener per 4 ft2 Adhesive Lim. OPTIONAL Simultaneously Min.0.5-inch TRUFAST DP#12 Fasteners and -45 S-AM-9 G33,L5 Approved Insulation secured with top layer DXF TRUFAST 3"Metal Insulation Plates 2 DF or DFP CR-20 (Lim.9) secured at a rate of 1 fastener per 4 ft OPTIONAL Simultaneously DL Plates&Fasteners DL,DT,DF -45 S-AM-10 G33,L5 Approved Insulation secured with top layer DXFWB Il secured at a rate of 1 fastener per 2.67 ft2 or DFP (Lim.9) S-AM-11 G33,L5 OPTIONAL Simultaneously DXF DL Plates&Fasteners -45 Approved Insulation secured with top layer secured at a rate of 1 fastenerper 2.67 ft2 DL SB IV (Lim.9) Duro-Fleece S-AM-12 G33,L5 OPTIONAL Simultaneously DXF DL Plates&Fasteners ..45 Approved Insulation secured with top layer secured at a rate of 1 fastener per 2.67 ft2 DF Membrane (Lim.9) Adhesive S-AM-13 G33,L5 OPTIONAL Simultaneously DXF DL Plates&Fasteners 2 DF or DFP CR-20 -45 Approved Insulation secured with top layer secured at a rate of 1 fastener per 2.67 ft (Lim.9) OPTIONAL SimultaneouslyTRUFAST DP#12 Fasteners and S-AM-14 G33,L5 DXC TRUFAST 3"Metal Insulation Plates DL,DT,DF WB II �5 Approved Insulation secured with top layer secured at a rate of 1 fastener per 2.67 ft2 or DFP (Lim.9) OPTIONAL Simultaneously TRUFAST DP#12 Fasteners and -45 S-AM-15 G33,L5 Approved Insulation secured with top layer DXC TRUFAST 3"Metal Insulation Plates DL SB IV (Lim.9) secured at a rate of 1 fastener per 2.67 ft2 OPTIONAL Simultaneously TRUFAST DP#12 Fasteners and Duro-Fleece -45 S-AM-16 G33,L5 Approved Insulation secured with top layerm.DXC TRUFAST 3"Metal Insulation Plates DF Membrane (Li9) secured at a rate of 1 fastener per 2.67 ft2 Adhesive _ OPTIONAL Simultaneously TRUFAST DP#12 Fasteners and -45 S-AM-17 G33,L5 Approved Insulation secured with top layer DXC TRUFAST 3"Metal Insulation Plates DF or DFP CR-20 (Lim.9) secured at a rate of 1 fastener per 2.67 ft2 S-AM-18 G33,L6 Min. 1.5-inch Simultaneously DDP or SR DL Plates&Fasteners DL,DT,DF WB II,SB IV -67.5 Fl,S24 Approved Insulation secured with top layer secured at a rate of 24 per 4 ft x 8 ft board or DFP or CR-20 (Lim.7) Min. 1.5-inch S-AM-19 G33,L6 OPTIONAL Simultaneously II-A,I!-G,Ill-A; DL Plates&Fasteners DF or DFP WB II -67.5 F1, S24 Approved Insulation secured with top layer or Min.2-inch secured at a rate of 24 per 4 ft x 8 ft board (Lim.7) IV-A S-AM-20 G33,L6 Min. 1.5-inch Simultaneously DDP or SR DL Plates&#15 Fasteners DL,DT,DF WB ll, SB IV -67.5 Fl,S24 Approved Insulation secured with top layer secured at a rate of 20 per 4 ft x 8 ft board or DFP or CR-20 (Lim.7) TRUFAST DP#12 Fasteners and S-AM-21 G33,L6 Min. 1.5-inch Simultaneously Min.0.5-inch DL,DT,DF SB IV or -82.5 Fl,S24 Approved Insulation secured with toplayer SR TRUFAST 3"Metal Insulation Plates pp y secured at a rate of 32 per 4 ft x 8 ft board or DFP WB II (Lim.7) S-AM-22 G33, L6 OPTIONAL Simultaneously Min.2-inch DL Plates&#15 Fasteners DL,DT,DF SB IV or -90 Fl,S24 Approved Insulation secured with top layer IV-A secured at a rate of 16 per 4 ft x 8 ft board or DFP WB II (Lim.7) DLR12001.14 FL16039-R14 Page 24 of 32 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING,INC. 4 CREEK PVC Single-Ply Roofing Membranes ANNI TECHNICAL SERVICES, LLC APPENDIX B Mechanically Fastened Assemblies over Steel Deck(New, Existing,or Recover) System Deck Base Base Top Insulation MOP No. Detail Insulation Insulation Top Insulation Attacment Membrane Attachment (psf) Attachment G33, Min 1-inch Duro-Last#15 EHD Drill Point fasteners -30 S M 1 L6,P or Approved Preliminarily DL and Duro-Last Poly-Plates or Cleat Plates (Lim.7; - -F1, SO Insulation secured fastened 12-inch o.c.along 6-wide tabs Non- spaced 120-inch o.c. HVHZ) G33, Min 0.5-inch Duro-Last#15 EHD Drill Point fasteners -37.5 S-M-2 L6,P, Approved preliminarily (Lim.7; - - DT and Duro-Last Cleat Plates fasetened 12- S24 Insulation secured inch o.c.within laps spaced 114-inch o.c. Non- HVHZ) G80, L5.5 Min 0.5-inch Duro-Last#15 EHD Drill Point fasteners S-M-3 (22 ga) Approved Preliminarily DT and Duro-Last Cleat Plates fasetened 12- -45 or L6 (Lim.7) Insulation secured inch o.c.within laps spaced 116-inch o.c. (18 ga) F1,S24 G33, Min 1.5-inch Preliminarily Duro-Last#15 EHD Drill Point fasteners -45 S-M-4 L6,Fl, Approved secured - - DT and Cleat Plates fastened 12-inch o.c. (Lim.7) S24 Insulation within laps spaced 56-inch o.c. G80, Min.1.5-inch Duro-Last#14 HD Fastener with Duro-Last PreliminarilyPoly-Plates or Cleat Plates fastened 12- -45 - - S-M-5 L6,F1, Approved secured DL inch o.c.along the 3-inch wide tabs (LIm.7) S24 Insulation spaced 60-inches o.c. G80, Min.1.5-inch Duro-Last#14 HD with Duro-Last Poly- S-M 6 L6,P, Approved Preliminarily - DL Plates or Cleat Plates fastened 6-inch o.c. -45 S24 Insulation secured along the 3-inch wide tabs spaced 84- (Lim.7) inches o.c. G33, Min 1-inch Duro-Last#15 EHD Drill Point fasteners Preliminarilyand Duro-Last Poly-Plates or Cleat Plates -45 - - S-M-7 L6,P or Approved secured DL attached 6-inch o.c.along 6-wide tabs (Lim.7) F1, SO Insulation spaced 120-inch o.c. G80, Duro-Last#15 EHD Drill Point Fastener Min.1.5-inch with Duro-Last Cleat Plates fastened 12- L6, Preliminarily -45 S-M-8 Approved - - DL inch o.c.along the 6-inch wide tabs F1W, Insulation secured spaced 120-inches o.c. Tab Sealer 4725 (Lim.7) S24 applied at 30 ft2/gal. Duro-Last#15 Extra Heavy Duty Drill Point G33, Fastener and Duro-Last Poly-Plates or Min.0.5-inch L6,PW Preliminarily Cleat Plates fastened 6-inch o.c.within 6- -45 S M-9 or F1, Approved secured - - DT inch wide laps spaced 114-inch o.c.; (Lim.7) S24 Insulation fastener centered 1.25-inches from edge of tab DLR12001.14 FL16039-R14 Page 25 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DURO-LAST ROOFING, INC. PVC Single-Ply Roofing Membranes 1 41 TECHNICAL SERVICES. LLC APPENDIX B Mechanically Fastened Assemblies over Steel Deck(New, Existing,or Recover) Base System Deck Base Insulation Top Insulation Top Insulation Membrane Attachment MDP No. Detail Insulation Attachment Attacment (psf) G80, Min.1.5-inch Duro-Last#14 HD Fastener with Duro-Last PreliminarilyPoly-Plates or Cleat Plates fastened 18- -52.5 - - S M-10 L6,Fl, Approved secured DL inch o.c.along the 3-inch wide tabs (Lim.7) S24 Insulation spaced 28 inches o.c. G80, Min.1.5 inch Duro-Last#14 HD Fastener with Duro-Last PreliminarilyPoly-Plates or Cleat Plates fastened 6-inch -52.5 - S M-11 L6,Fl, Approved secured DL o.c.along the 3-inch wide tabs spaced 60- (Lim.7) S24 Insulation _ inches o.c. G33, Min 1-inch Duro-Last#15 EHD Drill Point fasteners Preliminarilyand Duro-Last Poly-Plates or Cleat Plates -52.5 - - S M 12 L6,P or Approved secured DL fastened 6-inch o.c.along 3-wide tabs (Lim.7) Fl, SO Insulation _ spaced 60-inch o.c. G80, Min.1.5-inch Duro-Last#14 HD Fastener with Duro-Last PreliminarilyPoly-Plates or Cleat Plates fastened 6-inch -52.5 - S-M-13 L6, Fl, Approved secured DL o.c.along the 6-inch wide tabs spaced (Lim.7) S24 Insulation 120-inches o.c. Duro-Last#15 EHD Drill Point Fastener G80, Min.1.5-inch Preliminarily with Duro-Last 3-inch Metal Plates -52.5 S-M-14 L6,PW, Approved secured - - DL fastened 12-inch o.c.along the 6-inch wide (Lim.7) S24 Insulation tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. Duro-Last#15 EHD Drill Point Fastener G80, Min.1.5-inch Preliminarily with Duro-Last 3-inch Metal Plates -52.5 S-M-15 L6,PW, Approved secured - - DL fastened 6-inch o.c.along the 6-inch wide (Lim.7) S24 Insulation tabs spaced 84-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. G80, Duro-Last#15 EHD Drill Point Fastener Min.1.5-inch with Duro-Last Cleat Plates fastened 12- S-M-16 L6' Approved Preliminarily - - DL inch o.c.along the 6-inch wide tabs -52.5 Fl VV, Insulation secured spaced 84-inches o.c. Tab Sealer 4725 (Lim.7) S24 applied at 30 ft2/dal. G80, Min.1.5 inch Duro-Last#15 EHD Drill Point Fastener Preliminarily with Duro-Last Cleat Plates Fastened 6- -60 S-M-17 L6,PW, Approved secured DL inch o.c.along the 3-inch wide tabs (Lim.7) S24 Insulation spaced 84-inches o.c. Duro-Last#15 EHD Drill Point Fastener G33, Min.0.5-inch Preliminarily and Duro-Last Poly-Plates or Cleat Plates -60 S-M-18 L6,PW, Approved secured - - DT fastened 6-inch o.c.within 6-inch wide laps (Lim.7) S24 Insulation spaced 54-inch o.c.;fastener centered 1.25-inches from edge of tab DLR12001.14 FL16039-R14 Page 26 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. r CREEK PVC DURO-LAST ROOFING, INC. Single-Ply Roofing Membranes 1 TECHNICAL SERVICES. LLC APPENDIX B Mechanically Fastened Assemblies over Steel Deck(New, Existing, or Recover) System Deck Base Base Top Insulation MDP No. Detail Insulation Insulation Top Insulation Attacment Membrane Attachment (psf) Attachment Duro-Last#15 EHD Drill Point Fastener G33, Min.0.5-inch Preliminarily and Duro-Last Poly-Plates or Cleat Plates .67.5 S-M-19 L6,Fl, Approved - - DT fastened 6-inchwithin6-inchwidel secured asene -inco.c. laps Lim.7)Insulation spaced 54-inch o.c.;fastener centered ( 1.25-inches from edge of tab Duro-Last#15 EHD Drill Point Fastener G80, Min.1.5-inch Preliminarily with Duro-Last Batten Bar fastened 6-inch -67.5 S-M-20 L5,Fl, Approved secured - - DL o.c.within center of 3-inch wide tabs (Lim.7) S24 Insulation spaced 60-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. G80, Duro-Last#15 EHD Drill Point Fastener Min.1.5-inch with Duro-Last Cleat Plates fastened 12- S-M-21 L6' Approved Preliminarily - - DL inch o.c.along the 6-inch wide tabs -67'5 F1W, Insulation secured s aced 57-inches o.c. Tab Sealer 4725 {Lim.7) S24 p applied at 30 ft2/gal. G80, Min.1.5-inch Duro-Last#14 HD Fastener with Duro-Last S-M-22 L6,Fl, Approved Preliminarily - DL Poly-Plates or Cleat Plates fastened 12- -75 S30 Insulation secured (Inverted) inch o.c.along the 3-inch wide tabs (Lim.7) spaced 27-inches o.c. Duro-Last#15 EHD Drill Point Fastener G80, Min.1.5-inch Preliminarily with Duro-Last 3-inch Metal Plates -82.5 S-M-23 L6,P, Approved secured - - DL fastened 6-inch o.c.within center of 6-inch S24 Insulation wide tabs spaced 120-inches o.c. Tab (Lim.7) Sealer 4725 applied at 60 ft/gal. G80, Duro-Last#15 EHD Drill Point Fastener Min.1.5-inch with Duro-Last Cleat Plates fastened 6- S-M-24 L6' Approved Preliminarily -82.5 FI W, pp secured - - DL inch o.c.along the 6-inch wide tabs Lim.7 S24 Insulation spaced 120-inches o.c. Tab Sealer 4725 ( ) applied at 30 ft2/gal. G80, Duro-Last#15 EHD Drill Point Fastener Min.1.5-inch with Duro-Last Cleat Plates fastened 6- S M-25 L6' Approved Preliminarily -97.5 Fl W, pp secured - - DL inch o.c.along the 6-inch wide tabs S24 Insulation spaced 84-inches o.c. Tab Sealer 4725 (Lim.7) applied at 30 ft2/gal. G80, Min.1.5-inch Duro-Last#14 HD Fastener with Duro-Last S-M-26 L6,Fl, Approved Preliminarily DL Poly-Plates or Cleat Plates fastened 6-inch -105 S24 Insulation secured o.c.along the 3-inch wide tabs spaced 28- (Lim.7) inches o.c. DLR12001.14 FL16039-R14 Page 27 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. DURO-LAST ROOFING,INC. ACREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX B Mechanically Fastened Assemblies over Steel Deck(New, Existing or Recover) System Deck Base Base Top Insulation MOP No. Detail Insulation Insulation Top Insulation Attacment Membrane Attachment (psf) Attachment Duro-Last#15 EHD Drill Point Fastener G80, Min.1.5-inch with Duro-Last 3-inch Metal Plates Preliminarily -105 S-M-27 L6,P, Approved secured - - DL fastened 6-inch o.c.along the 6-inch wide (Lim.7) S24 Insulation tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. G80, Duro-Last#15 EHD Drill Point Fastener Min.1.5-inch with Duro-Last Cleat Plates fastened 6- S-M-28 L6' Approved Preliminarily - - DL inch o.c.along the 6-inch wide tabs -135 FiW, Insulation secured spaced 57-inches o.c. Tab Sealer 4725 (Lim.7) S24 applied at 30 ftZ/gal. Duro-Last#15 EHD Drill Point Fastener G80, Min.1.5-inch with Duro-Last Cleat Plates fastened 6- Preliminarily -142.5 S-M-29 L6,Fl, Approved secured - - DL inch o.c.within center of 6-inch wide tabs (Lim.7) S24 Insulation spaced 25-inches o.c. Tab Sealer 4725 applied at 60 ft2/gal. Induction Welded Assemblies over Steel Deck(New, Existing,or Recover) System Deck Base Layer Base Top Layer MOP No. Detail Insulation Insulation Insulation Top Insulation Attachment Membrane Attachment (psf) Attachment• - OPTIONAL G33,L6, Secured with Approved Duro-Bond#15secured 12-inch o.c.in rows spaced Induction welded to -45 S-W-1 Fl, S12 Approved Top Layer Insulation 48-inches o.c. DL60 each insulation plate (Lim.7) Insulation OPTIONAL G33,L6, Secured with Approved Duro-Bond#15secured 6-inch o.c.in rows spaced Induction welded to -45 S W 2 Fl, S12 Approved Top Layer Insulation 120-inches o.c. DL60 each insulation plate (Lim.7) Insulation OPTIONAL Secured with Approved Induction welded to -45 S-W-3 G33,L5 Approved Top Layer Insulation Duro-Bond#15secured 6 per 4 ft x 8 ft board DL or DT each insulation plate (Lim.9) ) OPTIONAL OMG XHD Fastener with Duro-Bond Plate 1302 or S-W-4 G33,L6, Approved Secured with Approved Duro-Bond PVC IW Plate secured at a rate of 1 per DL or DT Induction welded to -45 P,S24 Insulation Top Layer Insulation 6.00-ft2 each insulation plate (Lim.7) (See Appendix A-Induction Weld Pattems) OPTIONAL OMG XHD Fastener with Duro-Bond Plate 1302 or S-W-5 G33,L6, Approved Secured with Approved Duro-Bond PVC IW Plate secured at a rate of 1 per DL60 Induction welded to -45 Fl,S24 Insulation Top Layer Insulation 6.00-ft2 each insulation plate (Lim.7) (See Appendix A-Induction Weld Patterns) OPTIONAL OMG XHD Fastener with Duro-Bond Plate 1302 or S-W-6 G33,L6, Approved Secured with Approved Duro-Bond PVC IW Plate secured at a rate of 1 per DL or DT Induction welded to -52.5 Fl,S24 Insulation Top Layer Insulation 4.00-ft2 each insulation plate (Lim.7) (See Appendix A-Induction Weld Patterns) DLR12001.14 FL16039-R14 Page 28 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. , DURO-LAST ROOFING, INC. CREEKI PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX B Induction Welded Assemblies over Steel Deck(New, Existing,or Recover) _ System Deck Base Layer Base Top Layer MDP No. Detail Insulation Insulation Insulation Top Insulation Attachment Membrane Attachment (psf) Attachment OPTIONAL OMG XHD Fastener with Duro-Bond Plate 1302 or S-W-7 G33,L6, Approved Secured with Approved Duro-Bond PVC IW Plate secured at a rate of 1 per DL or DT Induction welded to -52.5 P,S24 Insulation Top Layer Insulation 4.00-ft2 each insulation plate (Lim.7) (See Appendix A-Induction Weld Patterns) OPTIONAL G33,L6, Secured with Approved Duro-Bond#15 secured 6-inch o.c.in rows spaced Induction welded to -52.5 S-W-8 F1 S12 Approved Top Layer Insulation 72-inches o.c. DL or DT each insulation plate (Lim.7) Insulation OPTIONAL G33,L6, Secured with Approved Duro-Bond#15 secured 6-inch o.c.in rows spaced Induction welded to -52.5 S W-9 Fl,S12 Approved Top Layer Insulation 96-inches o.c. DL60 each insulation plate (Lim.7) Insulation OPTIONAL OMG XHD Fastener with Duro-Bond Plate 1302 or S W-10 G33,L6, Approved Secured with Approved Duro-Bond PVC IW Plate secured at a rate of 1 per DL or DT Induction welded to -75 F1,S24 Insulation Top Layer Insulation 3.00-ft2 each insulation plate (Lim.7) (_See Appendix A-Induction Weld Patterns) OPTIONAL OMG XHD Fastener with Duro-Bond Plate 1302 or G33,L6, Secured with Approved Duro-Bond PVC IW Plate secured at a rate of 1 per Induction welded to -75 S-W-11 P, S24 Approved Top Layer Insulation 3.00-ft2 DL or DT each insulation plate (Lim.7) Insulation _ (See Appendix A-Induction Weld Patterns) OPTIONAL S W 12 G33,L6, Approved Secured with Approved Duro-Bond#15 secured 6-inch o.c.in rows spaced DL or DT Induction welded to -82.5 Fl,S12 Insulation Top Layer Insulation 48-inches o.c. each insulation plate (Lim.7) OPTIONAL G33,L6, Secured with Approved Duro-Bond#15 secured 6-inch o.c.in rows spaced Induction welded to -82.5 S-W-13 F1 S12 Approved Top Layer Insulation 60-inches o.c. DL60 each insulation plate (Lim.7) Insulation - OPTIONAL G33,L6, Secured with Approved Duro-Bond#15 secured 6-inch o.c.in rows spaced Induction welded to -90 S-W-14 Fl,S12 Approved Top Layer Insulation 48-inches o.c. DL60 each insulation plate (Lim.7) Insulation Assemblies with All Layers Adhered over Wood Deck(New or Existing) System Deck Detail Base Layer Base Insulation Top Layer Top Insulation Attachment Membrane Attachment MDP No. Insulation Attachment Insulation (psf) -75 W-A-1 T15/32,L24,0.113-6/6 - - DXC DG-CR DL or DT WB II or SB IV (Lim.9; "splatter pattern"at a rate of 6.8 lbs/sq Non- HVHZ) -75 W-A-2 T15/32,L24,0.113-6/6 - - DXC DG-CR DF or DFP WB I1 or CR-20 (Lim.9; "splatter pattern"at a rate of 6.8 lbs/sq Non- _ HVHZ) DLR12001.14 FL16039-R14 Page 29 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. - DURO LAST ROOFING,INC. CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX B Assemblies with All Layers Adhered over Wood Deck(New or Existing) System Base Layer Base Insulation Top Layer MDP r No. Deck Detail Insulation Attachment Insulation Top Insulation Attachment Membrane Attachment (psf) -97.5 W-A-3 T19/32,L32,0.113-6/6 - - DXF DG-CR DL or DT WB 11 or SB IV (Lim.9; "splatter pattern"at a rate of 6.6 lbs/sq Non- HVHZ) -97.5 W-A-4 T19/32,L32,0.113-6/6 - - DXF DG CR DF or DFP WB II or CR-20 (Lim.9; "splatter pattern"at a rate of 6.6 lbs/sq Non- HVHZ) Assemblies with Adhered Membranes over Wood Deck(New, Existing,or Recovery _ System Deck Detail Base Insulation o. Insulation Insulation Attachment Membrane Attachment Top P�fl W-AM-1 T19/32,L24,0.113-6/6 OPTIONAL DXF DL Plates&#15 Fasteners DL or DT WB l/or SB IV 52.5 Approved Insulation secured at a rate of 16 per 4 ft x 8 ft board _ (Lim.7) W-AM-2 T19/32,L24, 0.113-6/6 OPTIONAL DXF DL Plates&#15 Fasteners DF or DFP WB 11 -52.5 Approved Insulation secured at a rate of 16 per 4 ft x 8 ft board (Llm.7) W-AM-3 T19/32,L24, 0.113-6/6 OPTIONAL DXF DL Plates&#15 Fasteners DF or DFP CR-20 -60 Approved Insulation secured at a rate of 16 per 4 ft x 8 ft board (Lim.7) W-AM-4 T19/32,L24,0.113-6/6 OPTIONAL DXF DL Plates&#15 Fasteners DL or DT WB Il or SB IV -62.5 Approved Insulation secured at a rate of 18 per 4 ft x 8 ft board _ (Lim.7) W-AM-5 T19/32,L24,0.113-6/6 OPTIONAL DXF DL Plates&#15 Fasteners DF or DFP WB II -62.5 Approved Insulation secured at a rate of 18 per 4 ft x 8 ft board (Lim.7) W-AM-6 T19/32,L24, 0.113-6/6 OPTIONAL DXF DL Plates&#15 Fasteners DF or DFP CR-20 75 Approved Insulation secured at a rate of 18 per 4 ft x 8 ft board (Lim.7) Mechanically Fastened Assemblies over Wood Deck(New, Existing,or Recover) System Deck Detail Thermal Insulation Insulation Membrane Membrane Attachment MDP No. Barrier Attachment , , (psf) Min.0.5-inch Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -30 W-M-1 T15/32,L24,0.113-6/6 As required Approved Preliminarily DT Duro-Last Poly-Plates or Cleat Plates fastened (Lim.7; Non- Insulation secured 6-inch o.c.within 6-inch wide laps spaced 54-inch o.c HVHZ) Min.0.5-inch Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -30 W-M-2 T15/32,L24,0.113-6/6 As required Approved (Lim.7; q pproved secured DL Duro-Last Poly-Plates or Cleat Plates fastened Non- Insulation 6-inch o.c.within 3-inch wide tabs spaced 60-inch o.c. HVHZ) OPTIONAL Duro-Last#14 HD Fastener and -37.5 W-M-3 T19/32,L24,0.113-6/6 As required Approved Preliminarily DL Duro-Last Cleat Plates or Poly-Plates fastened (Lim.7; Non- Insulation secured 6-inch o.c.within 6-inch wide tabs spaced 120-inch o.c. HVHZ) DLR12001.14 FL16039-R14 Page 30 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. s DURO-LAST ROOFING,INC. le '. CREEK PVC Single-Ply Roofing Membranes TECHNICAL SERVICES. LLC APPENDIX B Mechanically Fastened Assemblies over Wood Deck(New, Existing,or Recover) System Deck Detail Thermal Insulation Insulation Membrane Membrane Attachment MDP No. Barrier Attachment (psf) Approved Preliminarily Duro-Last#15 Extra Heavy Duty Drill Point Fastener -45 T19/32,L32,0.113-6/6 As required Insulation secured DT and Duro-Last Poly-Plates fastened (Lim.7) 12-inch o.c.within 6-inch wide laps spaced 54-inch o.c Min.0.5 inch Duro-Last#15 Extra Heavy Duty Drill Point Fastener and W M 5 T19/32,L24,0.113-6/6 As required Approved Preliminarily DT Duro-Last Poly-Plates or Cleat Plates fastened -45 Insulation secured 6-inch o.c.within 6-inch wide laps spaced 114-inch o.c.; (Urn.7) fastener centered 2-inches from edge of tab Duro-Last#15 Extra Heavy Duty Drill Point Fastener Approved Preliminarily -52.5 W-M-6 T19/32,L32, 0.113-6/6 As required DT and Duro-Last Poly-Plates fastened 6-inch o.c. Insulation secured within 6-inch wide laps spaced 114-inch o.c (Lim.7) OPTIONAL Duro-Last#14 HD Fastener and W M 7 T19/32,L24,Hex-12/12 As required Approved Preliminarily DL Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. -52.5 Insulation secured into wood truss within 6-inch wide tabs spaced 120-inch o.c. (Lim.7) (Min.2.5-inch penetration into wood truss) Min.0.5-inch Duro-Last#15 Extra Heavy Duty Drill Point Fastener and W-M-8 T19/32,L24,0.113-6/6 As required Approved Preliminarily DL Duro-Last Cleat Plates or Poly-Plates fastened -52.5 Insulation secured 6-inch o.c.within 3-inch wide tabs spaced 60-inch o.c. (Lim.7) Min. 1.5-inch Duro-Last#15 Extra Heavy Duty Drill Point Fastener Preliminarily and Duro-Last Cleat Plates fastened 6-inch o.c. -52.5 W-M-9 T19/32,L24, 8d-6/6 As required Approved secured DL within 6-inch wide tabs spaced 57-inch o.c. (Lim.7) Insulation (Screws located 2.7-inches from tab edge) Min. 1.5-inch Duro-Last#14 HD Fastener and W-M-10 T19/32,L24,8d-6/6 As required Approved Preliminarily DL Duro Last 3-inch Metal Plates fastened 6-inch o.c. -52.5 Insulation secured within center of 6-inch wide tabs spaced 57-inch o.c. (Lim.7) Tab Sealer 4725 applied at 60 ft2/gal. Min.0.5-inch Duro-Last#15 Extra Heavy Duty Drill Point Fastener and Preliminarily -60 W-M-11 T19/32,L24,0.113-6/6 As required Approved secured DL Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. (Lim.7) Insulation within 6-inch wide tabs spaced 120-inch o.c. _ Min.0.5 inch Duro-Last#15 Extra Heavy Duty Drill Point Fastener and Preliminarily Duro-Last Cleat Plates or Poly-Plates fastened 6-inch o.c. -67.5 W-M-12 T19/32,L24,0.113-6/6 As required Approved secured DT within 6-inch wide laps spaced 54-inch o.c.; (Lim.7) Insulation fastener centered 1.25-inches from edge of tab Duro-Last#14 HD Fastener and Duro-Last Cleat Plates OPTIONAL fastened 6-inch o.c.into wood truss within center of W-M-13 T19/32,L24,Hex-12/12 As required Approved Preliminarily DL 6-inch wide tabs spaced 120-inch o.c. -82.5 Insulation secured (Min.2.5-inch penetration into truss). (Lim.7) Tab Sealer 4725 applied at 60 ft2/gal. DLR12001.14 - FL16039-R14 Page 31 of 32 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. 3-Part Specification OFFICE COPY Division 07 54 19-Polyvinyl-Chloride Roofing Ahern Townhouses 331 Ahern St. Atlantic Beach,FL 32223 2727 Prepared For: Prepared By:Eric Smith Energy Roofing -44 4 � Roof Assembly Description • PVC thermoplastic membrane Membrane Thickness:60 mil Color:White Attachment:Attached with mechanical fasteners • Polyisocyanurate(tapered) Attachment:Attached with mechanical fasteners • Fire rated slip sheet Thickness:2 plies Attachment:Loosely laid • 5/8 inch Plywood Roof Deck 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing PART l GENERAL 1.1 SECTION INCLUDES A. PVC thermoplastic membrane attached with mechanical fasteners. B. Polyisocyanurate(tapered), attached with mechanical fasteners. C. Fire rated slip sheet, loosely laid. D. Prefabricated flashings, corners,parapets, stacks,vents, and related details. E. Fasteners,adhesives, and other accessories required for a complete roofing installation. F. Traffic Protection. 1.2 REFERENCES A. NRCA-The NRCA Roofing and Waterproofing Manual. B. ASCE 7-Minimum Design Loads For Buildings And Other Structures. C. UL-Roofing Materials and Systems Directory,Roofing Systems(TGFU.R10128). D. ASTM C 1289- Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board. E. ASTM D 751 -Standard Test Methods for Coated Fabrics. F. ASTM D 4434- Standard Specification for Poly(Vinyl Chloride) Sheet Roofing. G. ASTM E 108- Standard Test Methods for Fire Tests of Roof Coverings. H. ASTM E 119- Standard Test Methods for Fire Tests of Building Construction and Materials. 1.3 SYSTEM DESCRIPTION A. General: Provide installed roofing membrane and base flashings that remain watertight; do not permit the passage of water; and resist specified uplift pressures,thermally induced movement, and exposure to weather without failure. B. Material Compatibility: Provide roofing materials that are compatible with one another under conditions of service and application required, as demonstrated by roofing membrane manufacturer based on testing and field experience. C. Sustainability: a. Conform to NSF/ANSI Standard 347,"Sustainability Assessment for Single-Ply Roofing Membranes. Minimum certification level: Gold. b. Type III product-specific Environmental Product Declaration. c. Membrane is recyclable at end of use. D. Physical Properties: 1. Roof product must meet the requirements of Type III PVC sheet roofing as defined by ASTM D 4434 and must meet or exceed the following physical properties. 2. Thickness: 60 mil,nominal,in accordance with ASTM D 751. 3. Thickness Over Scrim: >28 mil in accordance with ASTM D 751. 075419-2 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 4. Breaking Strengths:>390 lbf. (MD)and>438 lbf. (XMD)in accordance with ASTM D 751, Grab Method. 5. Elongation at Break:>31%(MD)and>31%(XMD) in accordance with ASTM D 751, Grab Method. 6. Heat Aging in accordance with ASTM D 3045: 176 °F for 56 days.No sign of cracking, chipping or crazing. (In accordance with ASTM D 4434). 7. Factory Seam Strength: >431 lbf. in accordance with ASTM D 751, Grab Method. 8. Tearing Strength:> 132 lbf. (MD)and> 163 lbf. (XMD)in accordance with ASTM D 751, Procedure B. 9. Low Temperature Bend(Flexibility): Pass at-40 °F in accordance with ASTM D 2136. 10. Accelerated Weathering:No cracking, checking, crazing,erosion or chalking after 5,000 hours in accordance with ASTM G 154. 11. Linear Dimensional Change: <0.5%in accordance with ASTM D 1204 at 176±2 °F for 6 hours. 12. Water Absorption: <2.6%in accordance with ASTM D 570 at 158 °F for 166 hours. 13. Static Puncture Resistance: >56 lbs. in accordance with ASTM D 5602. 14. Dynamic Puncture Resistance: > 14.7 ft-lbf. in accordance with ASTM D 5635. E. Cool Roof Rating Council(CRRC): 1. Membrane must be listed on CRRC website. a. Initial Solar Reflectance:>88% b. Initial Thermal Emittance: >87% c. Initial Solar Reflective Index(SRI):> 111 d. 3-Year Aged Solar Reflectance: >68% e. 3-Year Aged Thermal Emittance:>84% f. 3-Year Aged Solar Reflective Index(SRI): >82 F. Insulation 1. Provide overall thermal resistance for roofing system as follows: a. Average R-value: 13.1. 2. Tapered Insulation Slope: 1/4 inch per foot. 3. Configuration as indicated on the Drawings. 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 075419-3 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 2. Storage and handling requirements and recommendations. 3. Installation methods. 4. Maintenance requirements. C. Sustainability Documentation: a. NSF/ANSI Standard 347 Certificate. b. Type III product-specific Environmental Product Declaration. D. Shop Drawings: Indicate insulation pattern,overall membrane layout,field seam locations,joint or termination detail conditions, and location of fasteners. E. Verification Samples: For each product specified,two samples,representing actual product, color,and finish. 1. 4 inch by 6 inch sample of roofing membrane, of color specified. 2. 4 inch by 6 inch sample of walkway pad. 1. Termination bar, fascia bar with cover,drip edge and gravel stop if to be used. 2. Each fastener type to be used for installing membrane, insulation/recover board,termination bar and edge details. F. Installer Certification: Certification from the roofing system manufacturer that Installer is approved, authorized,or licensed by manufacturer to install roofing system. G. Manufacturer's warranties. 1.5 QUALITY ASSURANCE A. Perform work in accordance with manufacturer's installation instructions. B. Manufacturer Qualifications:A manufacturer specializing in the production of PVC membranes systems and utilizing a Quality Control Manual during the production of the membrane roofing system that has been approved by and is inspected by Underwriters Laboratories. C. Installer Qualifications: Company specializing in installation of roofing systems similar to those specified in this project and approved by the roofing system manufacturer. D. Source Limitations: Obtain components for membrane roofmg system from roofing membrane manufacturer. E. There shall be no deviations from the roof membrane manufacturer's specifications or the approved shop drawings without the prior written approval of the manufacturer. 1.6 REGULATORY REQUIREMENTS A. Conform to applicable code for roof assembly wind uplift and fire hazard requirements. B. Fire Exposure: Provide membrane roofing materials with the following fire-test-response characteristics.Materials shall be identified with appropriate markings of applicable testing and inspecting agency. 1. Exterior Fire-Test Exposure: 075419-4 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing a. Class A;ASTM E 108, for application and roof slopes indicated. 2. Fire-Resistance Ratings: Comply with ASTM E 119 for fire-resistance-rated roof assemblies of which roofmg system is a part. 3. Conform to applicable code for roof assembly fire hazard requirements. C. Conform to IECC(International Energy Conservation Code)and IGCC (International Green Construction Code)cool roof requirements. D. Wind Uplift: 1. Roofing System Design: Provide a roofing system designed to resist uplift pressures calculated according to the current edition of the ASCE-7 Specification Minimum Design Loads for Buildings And Other Structures. 1.7 PRE-INSTALLATION MEETING A. Convene meeting not less than one week before starting work of this section. B. Review methods and procedures related to roof deck construction and roofing system including, but not limited to,the following. 1. Meet with Owner,Architect,Owner's insurer if applicable,testing and inspecting agency representative,roofing installer,roofmg system manufacturer's representative,deck installer, and installers whose work interfaces with or affects roofmg including installers of roof accessories and roof-mounted equipment. 2. Review and finalize construction schedule and verify availability of materials,installer's personnel, equipment,and facilities needed to make progress and avoid delays. 3. Examine deck substrate conditions and finishes for compliance with requirements,including flatness and fastening. 4. Review structural loading limitations of roof deck during and after roofing. 5. Review base flashings, special roofmg details,roof drainage,roof penetrations, equipment curbs,and condition of other construction that will affect roofing system. 6. Review governing regulations and requirements for insurance and certificates if applicable. 7. Review temporary protection requirements for roofing system during and after installation. 8. Review roof observation and repair procedures after roofing installation. 1.8 DELIVERY, STORAGE AND HANDLING A. Deliver roofing materials to Project site in original containers with seals unbroken and labeled with manufacturer's name,product brand name and type,date of manufacture,and directions for storing and mixing with other components. B. Store liquid materials in their original undamaged containers in a clean, dry,protected location and within the temperature range required by roofmg system manufacturer. Protect stored liquid material from direct sunlight. C. Protect roof insulation materials from physical damage and from deterioration by sunlight, moisture,soiling,and other sources. Store in a dry location. Comply with insulation manufacturer's written instructions for handling,storing, and protecting during installation. D. Store roof materials and place equipment in a manner to avoid permanent deflection of deck. 075419-5 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing • E. Store and dispose of solvent-based materials,and materials used with solvent-based materials,in accordance with requirements of local authorities having jurisdiction. 1.9 WARRANTY A. Contractor's Warranty: The contractor shall warrant the roof application with respect to workmanship and proper application for two(2)years from the effective date of the warranty issued by the manufacturer. B. Manufacturer's Warranty: Must provide for completion of repairs,replacement of membrane or total replacement of the roofing system at the then-current material and labor prices throughout the life of the warranty. In addition the warranty must meet the following criteria: 1. Warranty Period: 20 years from date issued by the manufacturer. 2. First 15 years: a. Must provide for completion of repairs,replacement of membrane or total replacement of the roofing system at the then-current material and labor prices. b. No exclusions for incidental or consequential damages. 3. Last 5 years: a. Excludes incidental and consequential damages. 4. Must provide positive drainage. 5. No exclusion for damage caused by biological growth. 6. Issued direct from and serviced by the roof membrane manufacturer. 7. Transferable for the full term of the warranty. PART 2 PRODUCTS 2.1 MANUFACTURER A. All roofing system components to be provided or approved by roof system manufacturer. B. Acceptable Manufacturers: 1. Duro-Last,Inc. 2. 3. 2.2 ROOFING SYSTEM COMPONENTS A. Roofing Membrane: PVC thermoplastic membrane conforming to ASTM D 4434,type III, fabric-reinforced,PVC. Membrane properties as follows: 1. Thickness: a. 60 mil. 2. Exposed Face Color: a. White. B. Minimum NSF 347 Gold certified. 075419-6 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing C. Accessory Materials: Provide accessory materials supplied by or approved for use by roof system manufacturer 1. Sheet Flashing: Manufacturer's standard reinforced PVC sheet flashing. 2. Factory Prefabricated Flashings: manufactured using Manufacturer's standard reinforced PVC membrane. a. Stack Flashings. b. Curb Flashings. c. Inside and Outside Corners. 3. Sealants and Adhesives: Compatible with roofing system and supplied by roof system manufacturer. a. Caulk. b. Strip Mastic. 4. Slip Sheet: Compatible with roofing system and supplied by roof system manufacturer. 5. Fasteners and Plates: Factory-coated steel fasteners and metal or plastic plates meeting corrosion-resistance provisions in FMG 4470,designed for fastening membrane and insulation to substrate. Supplied by roof system manufacturer. a. #14 Heavy Duty Fasteners. b. Steel Membrane Plates. c. 3 inch Metal Plates. 6. PV Anchors 7. Termination and Edge Details: Supplied by roof system manufacturer. a. Termination Bar. 8. Vinyl Coated Metal: 24 gauge,hot-dipped galvanized, grade 90 metal with a minimum of 17 mil of PVC roofing membrane laminated to one side. 9. Two-Way Roof Vents: Supplied by roof system manufacturer.Install a minimum of 1 vent for each 1,000 ft2(93 m2)of roof area. D. Coated Glass Slip Sheet: 1. Fire rated slip sheet. a. 2 plies. E. Walkways: 1. Provide non-skid,maintenance-free walkway pads in areas of heavy foot traffic and around mechanical equipment. a. Walkway Pad. 2.3 ROOF INSULATION A. General: 1. Provide preformed roof insulation boards that comply with requirements and referenced standards,as selected from manufacturer's standard sizes. 2. Provide preformed saddles,crickets,and other insulation shapes where indicated for sloping 075419-7 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing to drain. Fabricate to slopes indicated. B. Polyisocyanurate Board Insulation: Complying with ASTM C 1289,Type II,felt or glass-fiber mat facer on both major surfaces. Material as supplied by roof system manufacturer. 1. Polyisocyanurate(tapered). 2.4 ROOF INSULATION ACCESSORIES A. General: Provide roof insulation accessories approved by the roof membrane manufacturer and as recommended by insulation manufacturer for the intended use. B. Fasteners: Provide factory-coated steel fasteners and metal or plastic plates meeting corrosion- resistance provisions in FMG 4470, designed for fastening insulation and/or insulation cover boards in conformance to specified design requirements. PART 3 EXECUTION 3.1 EXAMINATION A. Verify that the surfaces and site conditions are ready to receive work. B. Verify that the deck is supported and secured. C. Verify that the deck is clean and smooth, free of depressions,waves,or projections,and properly sloped to drains,valleys,eaves, scuppers or gutters. D. Verify that the deck surfaces are dry and free of standing water, ice or snow. E. Verify that all roof openings or penetrations through the roof are solidly set. F. If substrate preparation is the responsibility of another contractor,notify Architect of unsatisfactory preparation before proceeding. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. C. Surfaces shall be clean, smooth, free of fins, sharp edges, loose and foreign material, oil,grease, and bitumen. 3.3 INSTALLATION A. Install insulation in accordance with the roof manufacturer's requirements. B. Separation Slip Sheet: Fire rated slip sheet. 1. Install in accordance with the roof manufacturer's requirements. C. Insulation: Polyisocyanurate(tapered). 1. Install insulation in accordance with the roof manufacturer's requirements. 2. Insulation shall be adequately supported to sustain normal foot traffic without damage. 3. Where field trimmed,insulation shall be fitted tightly around roof protrusions with no gaps greater than ''A inch. 4. Tapered insulation boards shall be installed in accordance with the insulation manufacture's 075419-8 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing shop drawings. 5. No more insulation shall be applied than can be covered with the roof membrane by the end of the day or the onset of inclement weather. 6. If more than one layer of insulation is used,all joints between subsequent layers shall be offset by at least 6 inches. 7. Mechanical Attachment: Use only fasteners,stress plates and fastening patterns accepted for use by the roof manufacturer. Fastening patterns must meet applicable design requirements. a. Install fasteners in accordance with the roof manufacturer's requirements. Fasteners that are improperly installed must be replaced or corrected. 8. Mechanically attach Polyisocyanurate(tapered) insulation boards in parallel courses with end joints staggered 50%and adjacent boards butted together with no gaps greater than ''A inch. D. Roof Membrane: 60 mil,PVC thermoplastic membrane. 1. Use only fasteners, stress plates and fastening patterns accepted for use by the roof manufacturer.Fastening patterns must meet the applicable design requirements. 2. Install fasteners in accordance with the roof manufacturer's requirements. Fasteners that are improperly installed shall be replaced or corrected. 3. Mechanically fasten membrane to the structural deck utilizing fasteners and fastening patterns that in accordance with the roof manufacturer's requirements. 4. Cut membrane to fit neatly around all penetrations and roof projections. 5. Unroll roofing membrane and positioned with a minimum 6 inch overlap. E. Seaming: 1. Weld overlapping sheets together using hot air.Minimum weld width is 1-1/2 inches. 2. Check field welded seams for continuity and integrity and repair all imperfections by the end of each work day. F. Membrane Termination/Securement:All membrane terminations shall be completed in accordance with the membrane manufacturer's requirements. 1. Provide securement at all membrane terminations at the perimeter of each roof level,roof section, curb flashing, skylight, expansion joint, interior wall,penthouse,and other similar condition. 2. Provide securement at any angle change where the slope or combined slopes exceeds two inches in one horizontal foot. G. Flashings: Complete all flashings and terminations as indicated on the drawings and in accordance with the membrane manufacturer's requirements. 1. Provide securement at all membrane terminations at the perimeter of each roof level, roof section, curb flashing, skylight, expansion joint,interior wall,penthouse,and other similar condition. a. Do not apply flashing over existing thru-wall flashings or weep holes. b. Secure flashing on a vertical surface before the seam between the flashing and the main roof sheet is completed. c. Extend flashing membrane a minimum of 6 inches(152 mm)onto the main roof sheet beyond the mechanical securement. 075419-9 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing d. Use care to ensure that the flashing does not bridge locations where there is a change in direction(e.g. where the parapet meets the roof deck). 2. Penetrations: a. Flash all pipes, supports,soil stacks,cold vents, and other penetrations passing through the roofing membrane as indicated on the Drawings and in accordance with the membrane manufacturer's requirements. b. Utilize custom prefabricated flashings supplied by the membrane manufacturer. c. Existing Flashings: Remove when necessary to allow new flashing to terminate directly to the penetration. 3. Pipe Clusters and Unusual Shapes: a. Clusters of pipes or other penetrations which cannot be sealed with prefabricated membrane flashings shall be sealed by surrounding them with a prefabricated vinyl- coated metal pitch pan and sealant supplied by the membrane manufacturer. b. Vinyl-coated metal pitch pans shall be installed, flashed and filled with sealant in accordance with the membrane manufacturer's requirements. c. Pitch pans shall not be used where prefabricated or field fabricated flashings are possible. H. Roof Drains: 1. Coordinate installation of roof drains and vents specified in Section 15146-Plumbing Specialties. 2. Remove existing flashing and asphalt at existing drains in preparation for sealant and membrane. 3. Provide a smooth clean surface on the mating surface between the clamping ring and the drain base. I. Edge Details: 1. Provide edge details as indicated on the Drawings.Install in accordance with the membrane manufacturer's requirements. 2. Join individual sections in accordance with the membrane manufacturer's requirements. 3. Coordinate installation of metal flashing and counter flashing specified in Section 07620. 4. Manufactured Roof Specialties: Coordinate installation of copings, counter flashing systems, gutters,downspouts, and roof expansion assemblies specified in Section 07710. J. Walkways: 1. Install walkways in accordance with the membrane manufacturer's requirements. 2. Provide walkways where indicated on the Drawings. 3. Install walkway pads at roof hatches, access doors,rooftop ladders and all other traffic concentration points regardless of traffic frequency. Provided in areas receiving regular traffic to service rooftop units or where a passageway over the surface is required. 4. Do not install walkways over flashings or field seams until manufacturer's warranty inspection has been completed. K. Water cut-offs: 1. Provide water cut-offs on a daily basis at the completion of work and at the onset of inclement weather. 075419-10 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 2. Provide water cut-offs to ensure that water does not flow beneath the completed sections of the new roofing system. 3. Remove water cut-offs prior to the resumption of work. 4. The integrity of the water cut-off is the sole responsibility of the roofing contractor. 5. Any membrane contaminated by the cut-off material shall be cleaned or removed. 3.4 FIELD QUALITY CONTROL A. The membrane manufacturer's representative shall provide a comprehensive final inspection after completion of the roof system. All application errors shall be addressed and final punch list completed. 3.5 PROTECTION A. Protect installed roofing products from construction operations until;completion of project. B. Where traffic is anticipated over completed roofmg membrane,protect from damage using durable materials that are compatible with membrane. C. Repair or replace damaged products after work is completed. END OF SECTION 075419-11 OFFICE COPY 10';`44 1:3UROLAST All PRODUCT DATA SHEET ATLAS® FR-10/FR-50 FIRE BARRIER SLIP SHEETS DESCRIPTION: Fire retardant coated mat(roof system component). Features Benefits Proprietary coating Flame-retardant mat Ana \ ATL.' T1,14 S Tough and flexible Handles wind and foot traffic .,amu . Does not contribute to i Product composition corrosion or mildew Lines marked on roll Easy alignment for overlapping I Convenient roll size Easy to handle on the roof L r" wow, INTENDED USE: Thermal and fire barrier sheet listed by Underwriters I Laboratories for use under Duro-Last roofing I me di systems. FR-10/50 must be kept dry to retain its properties. MATERIAL SAFETY DATA SHEET: ,. • Product Name: Coated Glass Mat INSTALLATION: 1. FR-10/50 is part of a UL fire listed assembly when installed to meet Duro-Last roofing specifications. 2. The slip sheet should be rolled out and overlap the preceding sheets a minimum of 2 inches (51 GENERAL INFORMATION m(T1). 3. On sloped applications or in windy conditions, FR-10 FR-50 use adequate fasteners and distribution plates to Packaged Roll Roll hold in place until the roofing membrane is installed. Length 250 ft.(76.2 m) 105 ft.(32 m) Width 4 ft.(1.2 m) 4 ft.(1.2 m) Coverage 958 ft2(89 m2) 402 ft2(37 m2) with 2-inch(51 mm)overlap Roll weight 80 lb.(36.3 kg) 79 lb.(35.8 kg) Weight per area 0.08 lb./ft2 0.19 Ib./ftZ (0.39 kg/m) (0.93 kg/m2) www.duro-last.com 1 of 1 800-248-0280 Duro-Last and"World's Best Roof are registered trademarks owned by Duro-Last,Inc. Created:01/01/2009 Revised:01/12/2016 OFFICE COPY ice% DUROLAGT or A I PRODUCT DATA SHEET DURO-LAST® CLEAT PLATETM DESCRIPTION: -- The Duro-Last®Cleat Platen' is a 0.035-inch (0.9- mm)thick, 2-3/8-inch (60.3-mm)diameter galvalume plate. The Galvalume finish has proven weatherability and resiliency. Cleat Plates are packaged and sold in quantities of 1,000. 1 . Cleat Plates are stamped to include a recessed 0.265-inch (6.7-mm)diameter hole in the center and a series of ribs for added strength. The configuration —C1�.ti of the ribs and the hole is used to prevent the screw J I�i head from coming in contact with the Duro-Last } i roofing membrane. In addition to the stamped ribs, there are"cleats" stamped into the plate to hold the Duro-Last roofing membrane in place without tearing or puncturing the membrane in high-stress load applications. Also, because the cleats are not sharp, they are easier to handle. The Cleat Plate is a long-lasting and durable plate that is available from Duro-Last, Inc. INSTALLATION: vir 'Pr The Cleat Plate is installed with the"cleats"toward the membrane. When used with prefabricated mechanically fastened systems, the Cleat Plate can be used for securing Duro-Last membranes to the deck along the prefabricated fastening tabs and the edges of the sheet parallel to the tab direction.The Cleat Plate must be installed with the edge flush to the edge of the fastening tab. When used with the Duro-Roof®Roofing System, the Cleat Plate must be installed along the center of the 6-inch (152-mm)fastening tab. When used with adhered systems, the Cleat Plate must not be used for attachment of insulation or cover boards. www.duro-last.com 1 of 1 800-248-0280 Duro-Last,Duro-Roof and'World's Best Roof*are registered trademarks owned by Duro-Last,Inc. Created:10/01/2005 Revised:01/01/2009,01/06/2016,05/24/2016 OFFICE COPY �URvLAST V* PRODUCT DATA SHEET I..i.� ll DURO-LAST® INSIDE AND OUTSIDE CORNERS DESCRIPTION: Duro-Last®Inside and Outside Corners are to be used in corner areas encountered on a roofing project.The corners are made with Duro-Last specially formulated roofing membrane. The 40 combination of reinforced membrane and prefabrication ensures a long lasting, watertight flashing. Inside and outside corners are available in white, tan, gray and dark gray colors as well as in the Designer Series membranes(slate gray Shingle-Ply, sandstone Shingle-Ply and Rock Ply). They can be OUTSIDE CORNER ordered in 6 x 6 in. (152 x 152 mm)or 6 x 18 in. (152 x 457 mm)sizes. INSTALLATION: 1. Prefabricated inside and outside corners shall be heat welded (hot-air)to the field membrane and/or parapet flashings. 2. The use of outside corners is required but the use of inside corners is optional depending on the configuration of the flashing membrane. 3. Refer to detail 1180 for additional information. NOTE: • Inside and outside corners are manufactured from INSIDE CORNER Duro-Last membrane and shall be furnished by Duro-Last Roofing, Inc. •Outside corners must be manufactured by Duro- Last. • Inside corners may be fabricated in the field or ''''- I purchased from Duro-Last Roofing, Inc. • Butterfly corners are also available for use as �� --••, i shown in the drawing on the right. '-•� p I ��.,, °rOPet V40116X6 butterfly corner 6X6 inside (special order only) corner -�I6X6 outside corner (typ.) LOCATIONS TO USE CORNERS www.duro-last.com 1 of 1 800-248-0280 Duro-Last and"World's Best Roof are registered trademarks owned by Duro-Last,Inc. Created:12/21/2015 Revised 12/31/2015 OFFICE COPY 10"44� EURO►LAST PRODUCT DATA SHEET DURO-LAST® CURB FLASHINGS DESCRIPTION: Duro-Last® Curb Flashings are designed to be used on rectangular penetrations encountered on a roofing project. The curb flashings are made with Duro-Last specially formulated roofing membrane. The combination of reinforced membrane and prefabrication ensures a long lasting, watertight flashing. They are available in white, tan, • gray and dark gray colors as well as in the Designer Series membranes (slate gray Shingle-Ply, sandstone Shingle-Ply and Rock Ply). 11 , CLOSED Curb flashings are easily heat welded (hot-air) to the Duro-Last membrane over which the flashings are installed. Hot-air seaming eliminates the need for chemicals, torches and other unsafe, non- manageable seaming systems. Duro-Last Curb Flashings are prefabricated using Duro-Last's outside corners to eliminate field welds in the critical corner areas. Curb flashings are ordered to the dimensions of individual penetrations. The table below show the ii minimum sizes available. . 00" INSTALLATION: ii-siol , 1. The roof membrane installed around the penetration must be ' fastened prior to installing the curb flashing. Use the same fastener spacing that was used to install the roof membrane but 4 OPEN do not exceed 18 in. (457 mm)on center.At least one fastener must be installed on each side of the penetration. On reroofing applications, remove the existing flashings to ensure a watertight fit. 2. It is not necessary to place fasteners at the corners. 3. The flashing must extend a minimum of 8 in. (203 mm) in vertical height(note: a curb flashing with top does not have a minimum height requirement.) 4. The curb flashing may be terminated with termination bar or \ extended onto the inside of the curb. (See details 4010&4020). (Note:A curb flashing with top does not require termination.) ill 4110 NOTE: w/TOP •An "open"curb flashing requires a heat weld (hot-air)to close the flashing. The extra material necessary for this weld is included as part of the flashing. MINIMUM CURB SIZES AVAILABLE •A curb flashing for a canted curb should be ordered using the dimensions above the cant.A curb flashing with a 12 in. (305 mm) wider,(A) Length(B) Height(C) Skirt wide skirt will provide additional membrane to cover the cant. Open 2 in. 2 in. 8 in. 6 in. •A curb flashing with a top can be no greater than 60 in. (1525 mm) (51 mm) (51 mm) (203 mm) (152 mm) in width and can only be ordered closed. Closed 2 in. 2.5 in. 8 in. 6 in. (51 mm) (63.6 mm) (203 mm) (152 mm) •Add 1/4 in. (6.3 mm)to width and length dimensions for a better fitting curb flashing. WRop 3.5 in. 3.5 in. 3 in. 6 in. (89 mm) (89 mm) (76 mm) (152 mm) •Call Duro-Last for assistance in ordering curb flashings that need to be designed for special situations. www.duro-last.com 1 of 1 800-248-0280 Duro-Last and"Wodd's Best Roof are registered trademarks owned by Duro-Last,Inc. Created:01/01/2009 Revised:12/31/2015 A 4 DURQ'LAST® PRODUCT DATA SHEET DURO-GUARD® ISO II OFFICE COPY FLAT AND TAPERED PANELS Description: Duro-Guard®ISO II is a closed-cell polyisocyanurate foam core insulation board with an integrally laminated, fiber-reinforced facer which is compatible with Duro-Last®roof membranes. •r, • Available in both flat and tapered panels in order to meet thermal insulation needs as well as provide slope for proper roof drainage. • Manufactured with a blowing agent that has Figure 1.Duro-Guard ISO II Flat On Steel Deck zero ozone depletion potential (ODP)and virtually no global warming potential (GWP). Flat Panels: • Approved for direct application to steel and • Available sizes: other deck types. • 4 ft. x 4 ft. • Available in two grades of compressive o 4 ft. x 8 ft. strength per ASTM C 1289: o Thicknesses: 1 to 4 inches. o Type II, Class 1, Grade 2 (20 psi). • Refer to Table 2 for R-value and flute o Type II, Class 1, Grade 3 (25 psi). spanability. • Refer to Table 3 for physical properties. Tapered Panels: Recommended Uses: • Available sizes: • Mechanically attached Duro-Last roof systems. 0 4 ft. x 4 ft. • Adhered/Fully Bonded Duro-Last roof systems. o Thicknesses: 1/2 to 4-'h inches. • Duro-Bond®roof systems. • Precut miters and crickets are also available. • Metal retrofit roof systems. • Taper designs and shop drawings available. Underwriters Laboratories, Inc. Classifications: • UL 1256. • Insulated Metal Deck Constructions: o No. 120, 123, 292. 4.5• 12'nLl • UL 790. ''S" y • UL 263 Hourly Rated P Series Roof 25 r k Assemblies. 1.5" • UL Classified for use in Canada. .5- Factory Mutual Approvals: Figure 2.Duro-Guard ISO II Taper • FM 4450, FM 4470. TABLE 1. TYPICAL TAPER PANEL DIMENSIONS IApproved for Class 1 insulated steel,wood, SLOPE* SIZEMIN MAX• Q Q %="per ft. 4% 4 ft.x 4ft. '/:" 2--''/i' concrete and gypsum roof deck construction. QQ '/2"per ft. 4% 4 ft.x 4 ft. 2-%" 4-Y:" • Refer to FM Approval's RoofNav for details on x .1/4"per ft. 2% 4 ft.x 4 ft. ''A" 1-1/2" FM Approved systems (www.roofnay.com). Y '/ per ft. 2% 4 ft.x 4 ft. 1-1/2" 2-1/2" z Y,"per ft. 2% 4 ft.x 4 ft. 2-W 3-Ys" G '/4"per ft. 2% 4 ft.x 4 ft. 1" 2" H '/4"per ft. 2% 4 ft.x 4 ft. 2" 3" AA %"per ft. 1% 4 ft.x 4 ft. ''Y2" 1" A Y6"per ft. 1% 4 ft.x 4 ft. 1" 1'/z" B '/a"per ft. 1% 4 ft.x 4 ft. 1-1/2" 2" C %"per ft. 1% 4 ft.x 4 ft. 2" 2-'/z" *Contact Duro-Last for additional slope options. www.duro-last.com 800-248-0280 Duro-Last,'World's Best Roof and Duro-Guard are registered trademarks owned by Duro-Last,Inc. Created:01/17/2012 Revised:03/19/2013,10/31/2013,07/27/2016,01/29/2018 DURO-GUARDP:'ISO II OFFICE COPY Installation: • Panels must be kept dry before, during and TABLE 2. THERMAL VALUES after installation. Install only as much insulation THICKNESS" LTTR FLUTE SPANABILITY as can be covered the same day with inches mm R-VALUE inches mm completed roofing. 1.00 25 5.70 2.625 67 1.50 38 8.60 4.375 111 • The use of multiple layers of insulation with 1.60 41 9.10 4.375 111 joints staggered a minimum of 6 inches 1.70 43 9.70 4.375 111 between layers is recommended to eliminate 2.00 6 2.50 6 44 14.40 4.375 111 14.40 4.375 111 thermal bridging. 2.60 66 15.00 4.375 111 • Abut panel edges together and stagger joints of 2.70 69 15.60 4.375 111 adjacent panels. 3.00 76 17.40 4.375 111 3.30 84 19.20 4.375 111 • Boards must be neatly fitted to roof deck and 3.50 89 20.50 4.375 111 around penetrations with no gaps greater than 3.60 91 21.10 4.375 111 1/4 inch. 4.00 102 23.60 4.375 111 'Contact Duro-Last for additional thickness options. • Refer to the appropriate Duro-Last roof system specification and detail drawings for deck TABLE 3. TYPICAL PHYSICAL PROPERTIES preparation and attachment requirements. Grade 2 20 psi Compressive ASTM D 1621 (138 kPa) • Precautions must be taken to ensure that new Strength ASTM C 1289 25 psi concrete decks have fully hydrated and do not Grade 3 (172 kPa) continue to release moisture. Dimensional ASTM D 2126 2%linear change Stability (7 days) Panel Attachment: Moisture Vapor <1 perm • Panels may be attached to the roof deck using Transmission ASTM E 96 (85.0 ng/Pa•s•m2) mechanical fasteners, insulation adhesive or Water ASTM C 209 <1%volume hot bitumen. It is acceptable to use these Absorption products in combination. Service -40°to 200°F Temperature (-40°to 93°C) Mechanical Attachment • To ensure embedment, the board shall also be • When installing multiple layers (which may "stepped in"at several points while the bitumen include insulation, cover boards and thermal is still hot enough to allow positive attachment. barriers) it is acceptable to mechanically secure • Maximum panel dimensions are 4 ft. x 4 ft. through all layers. • Use fasteners and plates supplied by or • Any roof membrane contaminated with bitumen must be replaced. approved by Duro-Last, Inc. Storage: Adhesive Attachment • Insulation adhesive must be supplied by Duro- • Insulation must be protected from open flame Last, Inc. Refer to the adhesive's product data and kept dry at all times. sheet for application guidelines.Acceptable • Factory applied packaging is intended only for products: protection during transit. Slit or remove the o Duro-Grip®Insta-Stik". packaging to prevent accumulation of o Duro-Grip Olybond®. condensation. o Duro-Grip Millenium Weather-Tite®. • Store elevated (at least 3 inches)and o Duro-Grip CR-20. completely covered with a weatherproof covering such as a tarpaulin. • Subsequent layers of insulation and approved • Do not use panels which are wet or damaged. cover boards may be attached with insulation adhesive. • Refer to PIMA Technical Bulletin No. 109: • Maximum panel dimensions are 4 ft. x 4 ft. Storage and Handling Recommendations for Polyiso Roof Insulation for additional guidelines Hot Bitumen Attachment (www.pima.org). • When using hot bitumen on concrete decks, Limitations: priming is necessary. • Duro-Last, Inc.will not be responsible or liable • Temperature of the bitumen shall be for any defects or problems related to building approximately 50° F below the inter-ply hand or roof design by others,to deficiencies in mopping EVT. construction,to dangerous conditions on the • The deck shall be dry and care must be taken job site, or to improper storage, handling or to apply the bitumen in sufficient quantity to installation by others. totally cover the available deck surface. www.duro-last.com 2 of 800-248-0280 Duro-Last,'World's Best Roof and Duro-Guard are registered trademarks owned by Duro-Last,Inc. Created:01/17/2012 Revised:03/19/2013,10/31/2013,07/27/2016,01/29/2018 Uh ILt UUI3 Y iii° ,+� IDURO►LAST® PRODUCT DATA SHEET DURO-LAST® 60-MIL MEMBRANE Advantages: Duro-Last®60-Mil (DL60) membrane is an excellent choice for projects requiring a long lasting, energy efficient roofing membrane. The membrane is available in prefabricated sections or as roll goods. A complete line of custom prefabricated accessories is available for the DL60 membrane. Description: DL60 membrane is composed of PVC film laminated to both sides of a reinforcement fabric(weft-inserted scrim). Duro-Last membranes must not be used with Duro-Last EV membranes. PVC Film- Proprietary thermoplastic PVC formulation of resins, plasticizers, stabilizers, biocides,flame retardants, and U.V. absorbents. • PVC film above weft-inserted scrim—28 mil Cool Roof Rating Council (CRRC)1 Solar Thermal Solar Reflective Weft-Inserted Scrim-An 18 x 14 polyester fabric Reflectance Emittance Index(SRI) construction with weft insertion, composed of 840 x Initial 3-yr Initial 3-yr Initial 3-yr 1000 denier threads, provides superior tear and White 0.88 0.68 0.87 0.84 111 82 puncture resistance. The polyester thread is treated Tan 0.39 0.33 0.89 0.89 43 35 to prevent wicking. Gray 0.47 0.40 0.89 0.89 54 45 Dark Gray 0.26 0.25 0.88 0.89 26 25 Total Thickness—60 mil, nominal. 'Duro-Last's CRRC Product ID:0610. Weight—0.36 lb. per square foot. LEED&LEED-EB Credits-White DL60 membrane Colors—White,tan, gray and dark gray. alone can obtain 1 credit in either U.S. Green Building Council's LEED or LEED-EB programs. In R-Value—0.1 ft2•°F•hr/Btu. combination with other design criteria the membrane Available Configurations: may help attain other credits. Prefabricated Sections—DL60 is available in LEED Credit Category Duro-Last Attribute prefabricated sections up to 1,500 sq. ft. and is Sustainable Sites Credit 7.2 Solar Reflective Index(SRI) rolled on a carpet tube (maximum 65 ft.wide x 23 ft. Heat Island Effect:Roof SRI=111 long). LEED-EB Credit Category Duro-Last Attribute Roll Good— Typical Dimensions Sustainable Sites Credit 6.2 ENERGY STAR Qualified Length Approx. Approx. Heat Island Effect:Roof Thermal Emittance=0.87 Width (max.) Roll Area Weight Coverage' Warranty: 64 inches 100 ft. 533 sq.ft. 192 lb. 483 sq.ft. The following warranties are available for projects 48 inches 100 ft. 400 sq.ft. 144 lb. 350 sq.ft. utilizing DL60 membrane. Contact Duro-Last for 32 inches 100 ft. 267 sq.ft. 96 lb. 217 sq.ft. warranty details. 16 inches 100 ft. 133 sq.ft. 48 lb. 83 sq.ft. 'Assuming 6-inch overlap Available Warranties Energy Efficiency: Supreme 15-YR NDL 15+5 Material Only2 15+52 White DL60 membrane is an excellent product for complying with California Title 24, LEED®and other Ultra 15-YR Hail' 15-YR Hail& 15-YR High 20 YR High High Wind' Wind Wind energy efficiency programs requiring the use of a highly reflective roof membrane. It is an ENERGY Basic 15-YR NDL' 20 YR NDL' STAR®qualified product. Residential 15-YR Material Only' 20-YR Material Only' Excludes consequential damage coverage. Excludes consequential damage coverage for last 5 years. www.duro-last.com „2 800-248-0280 Duro-Last,"World's Best Roof,and Duro-Bond are registered trademarks owned by Duro-Last,Inc. LEED Is a registered trademark owned by the U.S.Green Building Council.ENERGY STAR is a registered trademark owned by the U.S.Environmental Protection Agency. Created:09/01/2012 Revised:11/13/2013,05/28/2014,06/05/2014,01/23/2015,05/18/2015,01/22/2016,02/15/2016,08/15/2017 DURO-LAST 60-MIL MEMBRANE OFFICE COPY Codes and Standards: Underwriters Laboratories (US & Canada), FM Approvals, ICC-ES (ESR-1660), Canadian Construction Materials Centre (CCMC 13299-L), State of Florida, Miami-Dade County, Texas Department of Insurance. Storage: Store rolls lengthwise on pallets. Use tarps to keep rolls dry. Membrane Attachment: Mechanically Fastened—DL60 membrane may be mechanically attached to a variety of roof deck and wall materials.An appropriate slip sheet or cover board may be required. Refer to the Duro-Last Mechanically Fastened Systems Specification for prefabricated system requirements. If using roll goods, refer to the Roll Good Mechanically Fastened Systems Specification. Duro-Bond°System—The Duro-Bond system (induction weld) may be used to attach DL60 membrane. Refer to the Duro-Last Duro-Bond System Specification for system requirements. Adhered— DL60 membrane may be adhered to a variety of properly prepared roof decks, walls, cover boards and insulations. Refer to the Duro-Last Adhered Systems Specification for system requirements. Physical Properties: DL60 membrane has been subjected to the tests required by ASTM 4434"Standard Specification for Poly(Vinyl Chloride) Sheet Roofing"and has been classified as a Type III, internally reinforced sheet. The results of each test are listed below.ASTM's Overall Thickness requirements for the membrane are plus or minus 10% (nominal) of the listed Typical Value. Physical Property Test Method ASTM D4434 Requirement Result Typical Value Overall Thickness ASTM D751 ?0.054 and<_0.066 in. PASS 0.060 in.(60 mil),nominal (>_54 and 5 66 mil) Thickness Over Scrim ASTM D7635 z 0.016 in. PASS 0.028 in.(28 mil) Breaking Strength' ASTM D751 Grab Method >_200 lbf./in. PASS 438 x 390 lbf./in. Elongation' ASTM D751 Grab Method Z 15% PASS 31%x 31% Seam Strength ASTM D751 Grab Method e ?328 Ibf. PASS 431 lbf. (75%of Breaking Strength.) Tear Strength' ASTM D751 Procedure B >_45 Ibf. PASS 132 x 163 lbf. Low Temp.Bend ASTM D2136 Must pass at-40°F. PASS PASS Heat A in ASTM D3045 Conditioned for 56 days in oven g g maintained at 176°F. PASS PASS 5,000 hours total test time. Accelerated Aging ASTM G154 Irradiance level of 0.68 W/m2-nm. PASS PASS (Formerly G53) Cycle:8 hours at 145°F, 4 hours condensation at 122°F Conditioned for 6 hours in oven Dimensional Stability' ASTM D1204 maintained at 176°F. PASS -0.45%x-0.20% Allowable change:5 0.5% Immersed in water at 158°F Water Absorption ASTM D570 for 168 hours. PASS 2.6% Allowable weight change:5 3% Static Puncture ASTM D5602 >_33 lbf. PASS 56 Ibf. Dynamic Puncture ASTM D5635 >_14.7 ft-lbf.(20 J) PASS >_14.7 ft-Ibf.(20 J) 'Typical values are shown for both machine and cross machine directions.The machine direction results are listed first. Additional Tests Fungi Resistance ASTM G21 No sustained growth or discoloration Moisture Vapor Transmission ASTM E96,Proc.B,Method A <0.35 U.S.perms ICC ��$Sri/4 ,,ou°,�° . le* ao c\ MIAMI.OAOE000NTY /� r,G�EfOflTHE . �� C CrU S i®G �[� ENE GYSTAR SPRI u,. APPROVED �cvs' CNAAAAA . • • 1.1N-I660 R10128 MEM[[[ www.duro-last.com 800-248-0280 Duro-Last,'World's Best Roof',and Duro-Bond are registered trademarks owned by Duro-Last,Inc. LEED is a registered trademark owned by the U.S.Green Building Council.ENERGY STAR is a registered trademark owned by the U.S.Environmental Protection Agency. Created:09/01/2012 Revised:11/13/2013,05/28/2014,06/05/2014,01/23/2015,05/18/2015,01/22/2016,02/15/2016,08/15/2017 UH-lUt UUI'Y DUROLAST 44 PRODUCT DATA SHEET DURO-CAULK® PLUS DESCRIPTION: 3. Apply the sealant using consistent, positive Duro-Caulk®Plus is a one-component, non-sag, pressure to force sealant into the joint, creating a elastomeric, neutral-cure silicone sealant. It is bead approximately 3/8 inch (9.53 mm) in available in white, gray, tan and bronze colors. Duro- diameter. Caulk Plus is formulated for use with all Duro-Last® 4. Tool the sealant to create a roofing system details that require sealant. concave joint shape to shed Duro-Caulk Plus is unaffected by most atmospheric water and ensure maximum conditions and will typicallycure within 48 hours. It is adhesion and coverage. Dry tooling is recommended. formulated to bond to substrates such as PVC, DO NOT use soapy water glass, aluminum, steel, plastic, ceramics, concretes, or other liquids when and wood. Its high-tack properties ensure a weather- tooling. tight seal around penetrations, terminations and drain inserts. 5. Sealant may be applied below freezing ORDERING: temperatures. IMMODuro-Caulk Plus is supplied in 10.1-ounce cartridges 6. Product will skin over within and can be ordered individually or in cases of 30. 20 minutes of application. hPURO LAS T One cartridge will cover approximately 18 to 20 The time may vary linear feet. depending on humidity and 1 SO.CAU • 10.1-ounce cartridge white (Item#1136) temperature at the time of application. St'e r.I A/V1 • 10.1-ounce cartridge tan (Item#1137) F CN • 10.1-ounce cartridge gray(Item#1134) STANDARDS: ..., • 10.1-ounce cartridge bronze (Item#1135) This product conforms with ;'{'' o,, California Air Resources Board -.«•� STORAGE AND HANDLING 2003 requirements for Volatile • ,. t RES' 1. Duro-Caulk Plus has a 12-month shelf life from Organic Compound content. . . the date of manufacture printed on the cartridge. PRECAUTIONS: 1. Read Safety Data Sheets (SDS) prior to using. 2. Wear proper personal protective equipment, such as gloves and eye protection, per the SDS. 3. Keep away from children. INSTALLATION: DURO-CAULK PLUS PROPERTIES 1. Limitations Sag resistance Non-sagging ASTM D2202 Bond durability to glass, , a. Apply to clean, dry surfaces free of aluminum and concrete t25/° ASTM C793 contaminants (oils, greases, coatings, etc.) that can adversely affect adhesion. Movement capability ±25% ASTM C719 b. Do not apply to surfaces that bleed oils or Tensile strength 300 psi ASTM D412 solvents. Elongation at break 325 ASTM D412 c. Product is not paintable. Hardness,Shore A 35±5 ASTM C661 2. Apply using a standard caulking gun. Do not open the cartridge until you are ready to apply Accelerated weathering No change Quv Weatherometer the sealant. Tack-free time 10 minutes ASTM C679 www.duro-last.com 1 of 1 800-248-0280 Duro-Last,Duro-Caulk and'World's Best Roof are registered trademarks owned by Duro-Last,Inc. Created:01/01/2009 Revised:07/16/2014,06/22/2018 OFFICE COPY fe'4%� DUROLAST PRODUCT DATA SHEET �i. DU RO-MASTIC® DESCRIPTION: Duro-Mastic®is a high-performance elastic butyl tape for use with the Duro-Last®roofing system. — Duro-Mastic is excellent in areas subjected to stress and vibrations as well as expansion and contraction. Duro-Mastic is especially effective in roofing .4111/1111111111111.1! applications as a sealant against moisture c.110111111.11.111111000simpeummill" , penetrations around flashings. IP Duro-Mastic is excellent in areas requiring superior tensile strength and extensibility, in all climates, which is most important with today's high tech single-ply materials. Duro-Mastic is formulated for jak cuao.u►sT adhesion to all types of building materials. Its � superior tack affords tenacious adhesion to -\UURO-M ;� aluminized steel, galvanized metal, masonry, and wood to ensure a weather tight seal. ' ° by 35 loot butyl WO Duro-Mastic is odorless, easy to use, and has high impact resistance. ORDERING: Duro-Mastic is available, with a paper backing, on 3/4-inch by 35-foot rolls, and packaged in cases of 10 rolls each. 2. Unroll and apply with constant, even pressure. STORAGE AND HANDLING Remove paper backing once ready to install 1. Protect product from freezing. membrane. 2. Store product between 40° F and 80° F for 3. A typical application is to use Duro-Mastic maximum shelf life. Shelf life is one year in between the membrane and wall before the unopened container when following these installation of Termination Bar(see Detail 6020). recommended storage procedures. 4. Refer to the most current Duro-Last specifications and details for more installation PRECAUTIONS: procedures. 1. Read Safety Data Sheets (SDS) prior to using. 2. Wear proper personal protective equipment, such DURO-MASTIC PROPERTIES as gloves and eye protection, per the SDS. 3. For industrial use only. Do not take internally. Service Temperature 60°F—212°F Keep out of reach of children. Specific Gravity 1.45 Solubility in Water Insoluble INSTALLATION: Solubility in Solvents Soluble in Most Solvents 1. Limitations Flexibility No Cracking at-60°F a. Apply to clean, dry surfaces free of Odor Odorless contaminants and frost that can adversely Sag None affect adhesion. • Heat Aging Cracking None b. Use in applications in which ultraviolet radiation exposure is not probable or Heat Resistance at 190°F No Blistering or Flow possible. www.duro-last.com 1 of 1 800-248-0280 Duro-Last,Duro-Mastic and'Wodd's Best Roor are registered marks owned by Duro-Last,Inc. Created:01/01/2009 Revised:06/04/2014 OFFICE COPY 44%, DLJRQ5T PRODUCT DATA SHEET ET DURO-LAST® HD SCREWS DESCRIPTION: Duro-Last®, Inc. requires the use of Duro-Coated ���� au% Screws for mechanical fastening of the Duro-Last my= roofing system. Duro-Last HD Screws are#14 diameter, are equipped with a P-3 truss head and 4i10 are available with either a drill point or a spade point. Duro-Last HD Screws can be used in most types of j roofing applications. These Duro-Coated Screws ig must pass twice the FM 4470 standard for corrosion 10— resistance, totaling 30 cycles in a Kestemich cabinet. Duro-Last, Inc. also requires that all Duro- Tot Coated Screws pass 20° and 40° bend tests Te (hardness)and be able to penetrate a 20 gauge ' deck in under three seconds with a 50 lb. (222 N) load. INSTALLATION: 1. Penetration into all approved deck types is 1 inch (25 mm) minimum,from the top surface of the deck. HD SCREW DIMENSIONS NOTE: Length Thread Length Quantity per Bucket • Duro-Last, Inc. stocks HD screws in the sizes 1.5 in.(38 mm) 1.5 in.(38 mm) 2,000 noted in the table to the right. Additional sizes are 2 in.(51 mm) 2 in.(51 mm) 2,000 available on a drop ship basis. Please allow adequate time for ordering and delivery of special 2.5 in.(64 mm) 2.5 in.(64 mm) 1,000 orders. 3 in.(76 mm) 3 in.(76 mm) 1,000 3.5 in.(89 mm) 3 in.(76 mm) 1,000 4 in.(102 mm) 3 in.(76 mm) 1,000 4.5 in.(115 mm) 3 in.(76 mm) 1,000 5 in.(127 mm) 4 in.(102 mm) 1,000 5.5 in.(140 mm) 4 in.(102 mm) 1,000 6 in.(152 mm) 4 in.(102 mm) 1,000 7 in.(178 mm) 4 in.(102 mm) 500 8 in.(203 mm) 4 in.(102 mm) 500 9 in.(229 mm) 4 in.(102 mm) 500 10 in.(254 mm) 4 in.(102 mm) 500 11 in.(279 mm) 4 in.(102 mm) 500 12 in.(305 mm) 4 in.(102 mm) 500 www.duro-last.com 1 of 1 800-248-0280 Duro-Last and'World's Best Roof"are registered trademarks owned by Duro-Last,Inc. Created:01/01/2009 Revised:04/06/2011,01/05/2016 OFFICE COPY `o"%;• DURO►LAST PRODUCT DATA r�.p. SHEET DURO-LAST® PARAPET FLASHING DESCRIPTION: Example#1 Duro-Last®Parapet Flashing is made with Duro-Last specially formulated roofing membrane. The combination of reinforced membrane and —1-- o� prefabrication ensures a long lasting, watertight flashing. The membrane 0L is available in white, tan, gray and dark gray colors as well as in the al 6 Designer Series membranes (slate gray Shingle-Ply, sandstone Shingle- �� E_ Ply and Rock Ply). 1- Heat welding (hot-air) is used to seam sections of parapet flashing A together and also to seam the parapet flashing to the Duro-Last membrane on the roof deck. Welds can be made with a hand-held unit 1—.A....-1_-___.B____1 or automatic welder. ----- The flashing can be mechanically attached or adhered to walls. No A= 6"(min.) 63"(max.) matter the method of attachment, mechanical fasteners must be used to B= 8"(min.) 28"(max.) secure roof-to-wall transitions and changes in slope, such as steps in the wall profile. The example drawings on this Example#2 p g page will help in understanding the T following installation guidelines as well as aid in the understanding the ( T fastener tab spacing that is specified when ordering these prefabricated I C flashings. i MECHANICAL ATTACHMENT: ,� + B If the parapet flashing is to be extended up the wall a short distance and terminated, such as shown in Example #1, the termination height must I be at least 8 in. above the roof deck. If the termination height exceeds 28 A in. at least one row of fasteners must be used to attach the flashing to I��I B C the wall as shown in Example#2. f When multiple rows of fasteners are required, such as shown in Example --' ' ------- #3, the maximum spacing between rows, or between a row of fasteners A= 6" min. 63" max. and the top of the wall, is 28 in. B= 6'r min. 25" max. Refer to the Duro-Last Mechanically Attached Systems specification for C= 6" min. 28" max. substrate and fastener requirements. ADHERED ATTACHMENT: Example#3 D Parapet flashing may be adhered to the wall with adhesive supplied by X— 1:11 Duro-Last. The minimum termination height is 8 in. above the roof deck. If the termination height exceeds 60 in., at least one row of mechanical N fasteners must be used. -�- C On tall walls multiple rows of fasteners may be required. The maximum spacing between rows, or between a row of fasteners and the top of the B wall, is 60 in. f Refer to the Duro-Last Adhered System specification for substrate and adhesive requirements. EAI B4- C 4 D—I ------------------------- A= 6" min.) 63" max.)) B= 6" min.) 25"(max.) C= 6" min.) 28"(max.)) D= 6"(min.) 63"(max.) www.duro-last.com 1 of 1 800-248-0280 Duro-Last and"World's Best Roof are registered trademarks owned by Duro-Last,Inc. Created:01/01/2009 Revised:12131/2015 OFFICE COPY DLJROLAGT ,-.Al PRODUCT DATA SHEET DURO-LAST® STACK FLASHINGS DESCRIPTION: Duro-Last®Stack Flashings are required for all round penetrations encountered on a roofing project. The stack flashings are made with Duro-Last specially formulated roofing membrane. The combination of reinforced membrane and 11 prefabrication ensures a long lasting, watertight flashing. CLOSED 411114111 Stack flashings are available in white, tan, gray and dark gray colors.They can also be ordered with Designer Series membrane(slate gray Shingle-Ply, sandstone Shingle-Ply or Rock-Ply)bases and solid OPEN color risers. They are available in diameters of 1 in. (25 mm), 1.5 in. (38 mm)and in 1 in. increments between 2 and 15 in. (51-381 mm). Stack Flashings with diameters of 16 in. (406 mm)and larger are 6. See details 4070, 4080 and 4081 for information available in 2 in. (51 mm)increments. on installing stack flashings to specific types of The flashings are manufactured oversized to round penetrations. account for the thickness a schedule 40 pipe wall by NOTE: the following amounts: •Stack flashings and bands shall be furnished by • 1.5-4 in. (38- 101 mm)diameter stack flashings Duro-Last, Inc. are 5/8 in. (15 mm)oversized. • Field fabrication of flashings for round penetrations •All other sizes are 3/8 in. (9 mm)oversized. is not allowed. INSTALLATION: • Stack flashings with diameters 16 in. (406 mm)and 1. The roof membrane installed around the larger are available"open"only. penetration must be fastened prior to installing •An "open"stack flashing requires a heat weld (hot- the stack flashing. Use the same fastener air)to close the flashing. The extra material spacing that was used to install the roof necessary for this weld is included as part of the membrane but do not exceed 18 in. (457 mm)on stack flashing. center. At least one fastener must be installed. On reroofing applications, remove the existing flashings to ensure a watertight fit. STACK FLASHING DIMENSIONS 2. Place the stack flashingaround thepenetration. Available Diameter Height Base/Skirt Heat weld the vertical seam if the stack was Closed Open ordered "open". 1 in. Yes No 8 in. 18 x 18 in.Base 3. Weld the stack flashing skirt to the roof (25 mm) (203 mm) (457 x 457 mm) membrane. Care should be taken to smooth out 1.5 in. Yes Yes 8 in. 18 x 18 in.Base the skirt so that it is wrinkle-free. (38 mm) (203 mm) (457 x 457 mm) 4. Apply a bead of Duro-Caulk Plus®to the 2—6 in. Yes Yes 8 in. 18 x 18 in.Base penetration 1/4 in. (6 mm)below the top of the (51—203 mm) (203 mm) (457 x 457 mm) stack flashing. 9—15 in. Yes Yes 8 in. 24 x 24 in.Base (228—381 mm) (203 mm) (609 x 609 mm) 5. Install a stainless steel band approximately 1/4 in. (6 mm)from the topof the stack flashing. 16 in. 8 in. 6 or 12 in Skirt (406 mm) No Yes (203 mm) (152 or 305 mm) Tighten the band to draw the flashing firmly into and Larger the sealant. Apply a bead of the Duro-Caulk Plus around the top of the flashing to assure a positive seal. www.duro-last.com 1 of 1 800-248-0280 Duro-Last and"World's Best Floor are registered trademarks owned by Duro-Last,Inc. Created:12/21/2015 Revised:12/31/2015 UI-HUE UOPY 10%;;;:- DURO►LAST PRODUCT DATA SHEET DURO-LAST® TERMINATION BAR DESCRIPTION: Duro-Last®Termination Bar(available in white, gray and tan colors)is fabricated from a rigid exterior vinyl with slotted holes 6 inches(152 mm)on center. Duro-Last Termination Bar may be used as perimeter detail for the Duro-Last roofing system and as termination on any square or rectangular penetration. Because of its symmetrical design, it is reversible. Duro-Last Termination Bar is available in 10 ft. (3 m) lengths only. Duro-Last, Inc.will supply the termination bar in multiples of 10 ft. (3 m)and has two standard packages. The small tube package contains a maximum of 170 ft. (52 m)while a large box contains a maximum of 500 ft. (152 m). MATERIAL SAFETY DATA SHEET: Product Identity: 10 foot Extrusions MSDS Number: 1225 INSTALLATION: 1. Duro-Last Termination Bar shall be fastened 6 inches (152 mm)on center with approved fasteners. 2. All termination bar must be fastened 1 inch (25 mm), maximum,from each corner or end of the bar. 3. The top edge of all sections of termination bar must be caulked. 4. It is necessary to leave a 1/4 inch (6.3 mm)space between all sections of termination bar to account for expansion and contraction. 5. All vertical applications require caulk on both sides. 6. Refer to details 3010& 3020 for installation information. www.duro-last.com 1 of 1 800-248-0280 Duro-Last and"World's Best Root"are registered trademarks owned by Duro-Last,Inc. Created:01/01/2009 Revised:01/06/2016