670 Plaza ROOF20-0012 Shingle/Rolled s-L'J,, ROOF NON SHINGLE PERMIT PERMIT NUMBER (,../ '7,ox, ,.� ROOF20-0012 �� j� ".,_ -) CITY OF ATLANTIC BEACH ISSUED: 3/19/2020 .; 800 SEMINOLE ROAD ``.-gri»~ ATLANTIC BEACH. FL 32233 EXPIRES: 9/15/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 670 PLAZA ROOF NON SHINGLE SHINGLE AND ROLLED $11340.00 ROOFING TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 171294 0000 ROYAL PALMS UNIT 02 COMPANY: ADDRESS: CITY: STATE: ZIP: RELIANT ROOFING INC 4230 Pablo Professional Ct #155 Jacksonville FL 32224 OWNER: ADDRESS: I CITY: STATE: ZIP: HAILEY GLENN 670 PLAZA ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS 'Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. f DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $110.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.48 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $169.48 Issued Date: 3/19/2020 1 of 2 1LAIN, ROOF NON SHINGLE PERMIT PERMIT NUMBER iiit r< CITY OF ATLANTIC BEACH ROOF20-0012 ult V" ISSUED: 3/19/2020 800 SEMINOLE ROAD '''''`'$ � ATLANTIC BEACH. FL 32233 EXPIRES: 9/15/2020 • Issued Date:3/19/2020 2 of 2 INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes,inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: Power Pole Final Plumbing Silt Fence Final Electrical Piers/Stem Walls Final HVAC Underground Plumbing CC Final Underground Electric Final Building* Foundation/Footing *For new living space:When all construction work including electrical,plumbing, mechanical,exterior finish,grading,required paving and landscaping is complete Slab** and the building is ready for occupancy,but before being occupied • `*FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION Swimming Pool Steel Retaining Wall Footing Swimming Pool Safety Driveway Electrical Grounding&Bonding Sewer(Building Dept) Swimming Pool Final(Bldg) Sewer Tap(Utilities Dept) Swimming Pool Final(PW) Additional inspections may apply to your project if your project Rough Electric* contains these elements: Rough Plumbing/Top Out* Formed Columns/Beams* Rough Mechanical* Masonry Cell Fill *When all rough electric,plumbing,mechanical are complete but before any work is *When forms and reinforcing steel,anchor bolts,sleeves and inserts,and all covered up. electrical,plumbing and mechanical work is in place,but before concrete is poured. House Wrap Structural Steel* Wall Sheathing *When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. Roof Sheathing OTHER: Tie-down Framing Connections OTHER: Rough Framing OTHER: Roofing In Progress OTHER: Window/Door In-Progress OTHER: Insulation Ceiling • SHik)GLE Insulation Wall RoU.ED orExterior Lath • Permit Type Stucco Scratch Coat Exterior Siding In-Progress RO0c Z 0 -• Oct I 2, Brick Flashing&Ties 6icr7c) Permit No. Early Power PGas Rough Job Address Gas Final* *When all gas piping is complete and wallboard is installed but before gas is RELin attached to any appliance.All outlets must be capped and pipe pressurized at a minimum of 15 lbs. Contractor POST THIS CARD WITH PERMITS AND PERMIT Building Department Public Works/Utilities Fire Department DOCUMENTATION IN FRONT OF BUILDING Phone:904-247-5826 Phone:904-247-5834 Phone:904-630-4789 Fax:904-247-5845 Fax:904-247-5843 Fax:904-630-4203 INSPECTION LINE: 904-247-5814 MUST CALL BY 4PM PREVIOUS DAY FOR NEXT DAY INSPECTION Construction Hours per City Code:lam--lpm Weekdays;9am-7pm Weekends , JOB copy ,oz, arr, Building Permit Application Updated 10/9118 ir,.i City of Atlantic Beach Building Department ' ated±;. ;;: ',,,, 800 Seminole Road, Atlantic Beach, 32233 >"I H , F: �aiaii t c FL :� t±v. .. .,,,5-3-.:-:..!:...,•:.f � w��r�`> Phone: (904) 247-5826 Email: ' `1s; -`I I�� -::',7 a is Building-Dept@coab.us . _. :'�• , ..,.:�. .. .. .:, Job Address: 670 Plaza Atlantic Beach,FL 32233 Permit Number: �R�� Zo—00 I Legal Description a- 30-9417-2S-29E ROYAL PALMS UNIT 2 LOT 21 BLK 8 RE# 171294-0000 Valuation of Work(Replacement Cost)$11340.00 Heated/Cooled SE Non-Heated/Cooled • Class of Work: ONew °Addition ®Alteration DRepair °Move °Demo OPool OWindow/Door • Use of existing/proposed structure(s): ❑Commercial WResidential ui N • If an existing structure,is a fire sprinkler system installed?: °Yes ®No z • Will tree(s)be removed in association with proposed project?CiYes(must submit separate Tree Removal Permit) ®No- J Z ~ . o M )}eserlbe,)ir�'tic�iJ t�e,tY}��o�1N,aFk`te_be perl;brrtited , . CLQ:s t- reroof,22 sq,2/12 pitch,shingles FL10124-R21 &26sq flat section,using rolled roofing,GAF Liberty SBS FL5680-R20 W': CI lil c°' o a Florida Product Approval# FL10124-R21 & FL5680-R20 for multiple products use product approval ne d 0 O Property Owner Information Q 7.f" a Z Name Glenn Hailey Address 670 Plaza 0 Q O < ... q C�Yah n,. ,---„,... ...._. City fAt antic t�eac)i�'•„� � State FL Zip32233 hon_e 770-314-7798 � • • T •�•vV�� � E-Mail ghaileyhi hlander _ oo.com �� - "'1�”"a 1M- 7 Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) 0 LL. 2 s Contractor information 0 0 illa. W m Name of Company Reliant Roofing Qualifying Agent Cameron Shouppe W 1- W DCI Address'4230 Pablo Professional Ct#155 Cityf Jacksonville State j iI Zip132224 _ W V N g u! Office Phone 530-057-088,xlob Site Contact Number 904-712-3111 —. CC W State Certification/Registration#:CCC1330615 E-Mailµamanda(cD_re)iantroofinq.com., . . ., ill > Architect Name&Phone# — LC CC Engineer's Name&Phone# Workers Compensation Insurer Qglipy#',WC196 .9226_ OR Exempt q Expiration Date 11/20/2020 Application is hereby made to obtain a permit to do the work and installations as Indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE Io additiAn tp't1 a Y:44,eme�10:04, )?Se{�ad#J�fh0 maybe a(ddi iott restr(cti,.a,0 l*itcap(e to;thi. property that may be:f000. In t(1e pul ire*. r ` 7 theye;may be add�tin()a.C,perrrr)ts r guged from other governmental entltie such as water :arlageri ent,di f fl ` kit0.0 agpn l i OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. FEB 2 5 2020 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. . o)q 1NT,ENDrtl7i+w'nt TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY(B ORE RECORDING Y TICE OF COMMENCEMENT. "Y �`"t�`t tIC fDC�, E_ (Signature of Owner or Agent) (Signature ontr o Sign and sworn to(o4 affirmed)before me this 6 day of Signed and sworn to(or affirmed before me this 1-2,_day of ap. ,by C3 it Of) ai1G3 Vet . 2A7M,by __ ii - toa a. .. .t' AMANDA e.JACltS,�P�' 'i"'". ,a��►...e'.. �►.. ��A. � ,..�n "" ignatureo tory) -�.` '/,� '=State of Florida-Notary Public' „ Yp�,, '•MAN OA JACKSGN . Commission#GG 205328 a ;'rule t;: My Commission Expires rr�dit-.. Stateof Commission Public ”"""` Persona4l Nh8Bn2 2 Personal) Known OR 05328 i -I' ,'S My commission ion GG Expires (4 �` &•Tri^ yq V d M Expires r,., O Produced Identification ',4„1;°o` y April 09,2022 Type of Identification:_*1ltSti Cly\Skr 9r4&Yj)j- Type of Identification: JJ I 1 3 JOB COPY NOTICE OF COMMENCEMENT !PREPARE IN DUPLICATE, Permit No./id( DZ 026— oi _ Tax Folio No. State of Florida County of tp L,,v 41 To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal des iption of prope ••ein. improved. I • • a v .t� ��ri��i Address of property being improved &T(> ? a'la _ 3 33 General aescnptton of improvements: Roof Replacement Owner C\enrt 1._4�\\•eV Address_C9-1 / 10 ?`aZ —C� 3 a g-__53 O'.vner's interest in site of the impro,:ement ©c c ry Fee Simple Titleholder(If other than owner) Name Address contractor Reliant Roofing Address 4230 Pablo Professional Ct#155 Jacksonville FL 32224 Phone No.904-657-0880 Fax No. Surety(if any) Address Amount of bond$ Phone No. Fax No. Name end address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than mmset!.designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No, In addition to himself.owner desionates the following person to receive a copy of the Lienors Notice as provided in Section 713.06(2)(b).Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY lMQ ,f/t/ , / OWNER s,gned: v � . e.-E 27►t-2D ; Before me this { day of Q91.'saldf\ ..,:ti . i.• Doc#2020033957,OR BK 19102 Page 824, c '.t of Duval. - •or F .... :_pets.,. Number Pages: 1 • rr r"'"' **DA JACKSON NmselG hersen ane a.rms that all.tateme a •t!—.11:.-, '* i Recorded 02/12/2020 10:34 AM, ' am tate and accurate �` tt:'�ta rbt Flofida•Not 20 Public RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL ;` Commission dna.; GG 205328 COUNTY ,� •P; My Commission ExPiros or RECORDING $t 0.00 '�,•;,r�,, �' April 09.2022 : n.17• ' at Lin. t-t of_ 7 -7 County or 111tVliki by corn on expires: —w Q/�yp • peau,-• ,.ntecalion '•OJI\\lir���111n�l1\'t►"a1i JOB COPY CatejoryjSubcategary Manufacturerpti _ :'Product Desch ori_� Limitat~�n`�Use. � - State-It-_ C.PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles GAF Timberline HD Architectural FL10124-R21 2. Underlayments GAF Feltbuster FL18686-R1 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing GAF Liberty SBS FL5680-R20 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16.Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 10/17/18 JOB COPY In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name(Print Name):Cameron Shouppe *Contractor Signature: Reliant Roofing *Company Name: *Mailing Address: 4230 Pablo Professional Ct #155 *City: Jacksonville *State: FL *Zip Code: 32224 *Telephone Number: 9046570880 *E mail Address: amanda@reliantroofing.com Cell Phone Number: 9047123111 Fax Number: Page 4 of 4 Updated 10/17/18 r ; JOB COPY LibertyTM SBS Self-Adhering Roofing System Information Sheet Updated: 9/06 REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REOUIRErJ E,\I rryS�AND CONDITIONS/ REVIEWED BY: / DATE: 3//8f 2.6 A Quality You Can Trust Since 1886... From North America's Largest Roofing ManufacturerTM GAF MATERIALS CORPORATION r 1 t ifa •bortv GAF MATERIALS CORPORATION SBS Self-Adhering Roofing System How Do I Prepare for a Liberty'" Project? Before You Start...the installation of your new Liberty"SBS Self-Adhering Roofing,do the following: •Read Instructions Thoroughly...and understand how the entire system works before starting your installation. •Understand The Materials...know when and where to use each component,why each is necessary,and the common mistakes to avoid. •Contact GAF Contractor Services...at 1-800-ROOF-411 for detailed information on specific applications or consult the technical specification for detailed application instructions. Do's And Don'ts...Liberty"SBS Self-Adhering Roofing Systems are designed to be installed over low sloped roof decks. •Do Install On Roofs Between 1/2"And 6"Per Foot...and backnail the Liberty"Cap Sheet when the slope is greater than 1"per foot.Contact GAF Contractor Services at 1-800-ROOF-411 for fastening requirements specific to your project. •Do Install In Moderate Temperatures...between 45°F(7°C)and 95°F(35°C),to assure proper adhesion and easier work conditions. •Do Follow Proper Storage Recommendations...Keep material clean and dry.In cooler weather,24 hours prior to application store at 55°F(12.8°C)for best installation result. Look for these important safety symbols •Do Install Over Clean Surfaces...that are free of dirt,moisture,debris,damage or are otherwise unsuitable for installation. •Don't Work Alone...GAF recommends between 2 and 4 people to install Liberty'SBS Self-Adhering Roofing. ''-- Wear Glasses SAFETY FIRST...Protect yourself and others.Consider the following common sense safety precautions,including: •Wear appropriate clothing,including protective footwear,eye wear and gloves. Nit Wear Gloves •Be aware of your surroundings.Watch for power lines when working near ladders and use common sense on your jobsite. •Follow local building codes. Common •Bend at the knees.Never lift with your back. Mistakes and How to Precautionary Note: The application instructions for this product require the use of primers,adhesives or cements that contain Avoid Them solvents.Apply solvent-based products ONLY as instructed.Excess application of solvent-based products may affect the performance of this product,delay application of the cap sheet,cause surface blistering of the cap sheet or result in the asphalt flowing,dripping or staining.You may notice unpleasant odors from the solvents,which will dissipate when the solvent-based product has dried. What Tools & Equipment Do I Need to Install a Liberty'" Roof? _ ) '2' # \ / a, ro) ,___, ..__,,,==, i , ...__ i, Trowel Gloves Hammer Utility Knife Weighted Roller Brush Tape Measure Caulk Gun Liberty Installation Kit Liberty'" Roof Materials... What Do I Need to Install a Quality Roof? •Liberty Installation Kit...comes with enough primer and cement to install approximately 200 square feet of membrane. Additional kits or extra primer and cement may be purchased if necessary. •Liberty"Self-Adhering Base/Ply...is the base weatherproofing layer when applied over acceptable,prepared decks or insulations.Each roll contains approximately 200 square feet. •Liberty"Mechanically Attached Base...is applied when the deck is unsuitable for self-adhered sheets or when a nailed base sheet is preferred.Each roll contains approximately 200 square feet. •Liberty"Self-Adhered Cap...is the first line of defense from the weather.Each roll contains approximately 100 square feet. •Metal Flashing...for covering roof perimeter edges.Metal flashings are typically sold in 10 foot sections and must be primed with asphalt primer and allowed to dry before installation. •Everything Else...when measuring,note the size and number of vent pipes,and other flashings.Don't forget any nails,lumber or other additional material that you may need. Liberty"Roof Systems... Which roof is righ - 2-Ply Lay-out(SA Base) 2-Ply Lay-out(MA Base) 3-Ply Lay-out MZ""" Bailable Deck Ayalli k DuraGo -� Apirlirel � Mailable Dee 4qj min 1'MM 2'Nln SiEe Lap IM SIEe1 SiEe Lap / � h•_I I r 1 feallitAf 111 1"Min We SiEe Lap ��TMin 19^K rir 1 Mm LIBERTY' LIBERTY" as Marty' UMW 9"MaA. LIBERTY" LIBERTY' BASE/PLY SHEET CAP SHEET MA Bate Sheat Cap Cant LIBERTY-EIA BASE/PLY SHEET CAP SHEET Note:Sin.le Ply applic. -e not shown;visit www.•. •m for details if required. A JOB COPY STEP 1 - Preparing for a Liberty" Roof... Is the Surface Ready? it in r •Remove All Existing Roofs...and determine the suitability of the existing roof deck.Alternately, II ' ' Liberty MA base may be installed over certain roof types or deck types not listed.Contact GAF Contractor Services at 1-800-ROOF-411 for more information. a a a a •Inspect The Deck...and determine what type of preparation is required.Replace damaged deck materials as necessary. No •Install Insulation(if desired)...using GAF DRILL-TEC'°screws and plates or GAF approved adhesives. 0 0 ° Use minimum 1/2' thick EnergyGuard''Polyiso insulation with approved fiberglass or paper facer. 111 r tails" r Acceptable Decks o o ° 15/32"Minimum Plywood Apply light asphalt primer at 1/2 to 3/4 gal per 100 sq.ft. GAF EnergyGuard Polylso Insulation Install Self-Adhered Liberty Base Sheet directly to insulation \Other Deck Types May Be Acceptable Contact GAF Contractor Services at 1-800-ROOF-411 for more informatio --a a a a a 0 0 Common Mistakes(and How to Avoid The m)... / Figure 2-1 (Fastening) •Poor Roof Drainage...can lead to leaks at the seams.Before installation,fix the roof deck at locations where water remains after 48 hours. Liberty"SBS cap She (OPTIOA A .Not PrimingThe Deck...or metal maylead topoor adhesion and is a leadingcause of problems. 114'DxALl 1/e-Deep Ribbon m LeakBuslere •Not FollowingProper Stora a Recommendations...Be sure rolls are stored at 55°F for 24 hours prior M"ds12o,SBS Cement Covering 9 P The Edge Beneath tr To IS'application. Clip Underside Comers Al 45* STEP 2 - Installing Liberty'" Base Sheet... nailed base or adhered base? Angle At All End Laps ME 1.Align Base Sheets...Starting at the lowest point of the roof where there are gutter or fascia edges,extend ., a Mia the base sheet over and down the fascia fully behind the metal edge or gutter height,fastened along roof edge and along fascia 9"o.c.Minimum overhang is 1".Begin with 1/2 width(19 11/16")sheets in 2-ply ,.,, systems.We 1/3 wrdth(18 1/8")otartcr ahccto in 8 ply ayatcma and inotall 2'ply(intorply ohoot) ,_I. a'.arttng with 1/2 width(19 11/16")ohcota to rrc!rtain sick lap cffocta. ,e 2. 41 L� 3.Install SA Base Sheet...by aligning sheets properly before removing the release liners.Roll out sheet 'r Illi 1n I Bee otLeamu>,.rn and let it sit or"relax"for at least 30 minutes to minimize the potential for wrinkles that can form during 'r.- till Meld:4201 SBS Cement installation.Remove one side of the release liner at a time. 'Ill' 4.Overlap Following Rows of Base Sheet...horizontally(side lap)by using the line found on the base sheet.Remove release films from top and bottom half of sheet in turn,carefully rolling back into position to maintain overlap Where no line is present,overlap by 3".Overlap vertically(end laps)by at least 6". Make sure all end laps are at least 18"apart. Figure 3-1 (End Lap) 5.Roll Base Sheet Into Place(SA Base Only)...using a weighted lawn or linoleum roller.This improves adhesion to the deck and ensures properly sealed laps. Primed Edge Fleshing,Min.4"Flange Set In leak Buster,'Matrix 1201 SBS Cement leak Buster".Matrix NOTE:A base sheet is not required;visit www.gaf.com for more information. /I201 SBS Cement Common Mistakes(and How to Avoid Them)... •Not LettingThe Sheets Relax...can lead to wrinkles.In colder weather,the rolls require more .off iA`.�i a:t Liberty q ��.�// Liberty"Cap Sheet Atime to flatten and return to adequate installation temperature. ��1// i / •Not Rolling The Base Sheets...Is a leading cause of opening laps.Always pay close attention to laps when rolling the base sheets. '"'" \�` Leak BMW' NOTE:Never install wet or damaged material.Only install membrane when temperature is 45°F and rising. ice` 1201 OS Comsat 111 Fasteners 3'0.C.Staggered STEP 3 - Installing Liberty'" Cap Sheet... Where Do I Begin? t.'; like 1.Install Edge Flashing...over the base sheet in an 1/8"bed of cement and stagger nail with two rows of13 11v' ��'ll�Liberty Bas.sheet roofing nails,3"oc.Prime the face on the roof and allow to dry before installing cap sheet. �/ ��11 2.Align Cap Sheet... 1/4"from the edge at the lowest point of the roof.Roll out and position full Pnuun Treated Wood width(39 3/8")sheets with the selvage edge on the high side of the roof.Allow sheet to relax Nailer Mechaniullr Fastened EnergyGoard"Insulation for at least 30 minutes prior to installing. Edge Flashing No 3.Overlap Following Rows...horizontally(Side Lap)by aligning with the bottom of the selvage edge. 1 Vertical(End Laps)must be overlapped by at least 6"and applied in a 1/8"bed of Leak Buster"Matrix' Shingle andedarment #201 SBS Cement.Make sure all end laps are at least 18"apart and have clipped corners(Figure 3-1). Shingles GAF recommends installing a bead of plastic cement along the step up length of the lap. 4.Remove Release Films...from top to bottom half of sheet in turn,carefully rolling back into position • to maintain overlap.Remove selvage edge release film prior to installing bottom half of sheet and Fasteners 1111111kfinishing the side lap. 'Oars`''` 5.Roll the Cap Sheet Into Place...using a minimum 50 lb weighted roller.This improves adhesion to �m,r the base sheet and ensures properly sealed laps. flashing must Common Mistakes(and How to Avoid Them)... 571%.. of shingles. •Not Priming the Edge Metal...can cause the cap sheet to peel away at the edges.Always prime ,r edge metal before installing cap sheet. % Fasteners •Not Applying Cement at the End Laps...Can cause laps to open.All locations where sheets extend •tpfes PP/Y� 9P B o.e. over granules must be set in cement. ---ahem. 5 Mashing mull STEP 4 - Cleaning Up and Maintaining Your Liberty" Roof... extenda um 3 courses of Maths'.201 Premium •Remove All Tools and Materials From the Roof...and make sure there is no debris that can slow or shingles. SBS Flashing Cement stop the flow of water Plywood Beck •••,11? •Dispose of Materials Properly...following all federal,state and local laws. Shingle Tie-In •Inspect the Roof Annually...and remove any leaves,branches or vegetation that may be present.Look SIor other damage and repair if necessary. �;�� •Keep Gutters Clean...to ensure proper water flow and minimize the possibility of damaging ice dams. SBS Self-Adhering Reefing System 02006 GAF Materials Corporation 9/06 RESLB108 r7 , City of Atlantic Beach APPLICATION NUMBER ` •;),,, Building Department (To be assigned by the Building Department.) n � _� 800 Seminole Road R OO F Z O _0O1 Z ._ 1 Atlantic Beach, Florida 32233-5445 v Phone(904)247-5826 • Fax(904)247-5845 . E-mail: building-dept@coab.us Date routed: z City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: '7O P LA-zA De artment review required Yes/No uilding Applicant: R GLI P01- ROOF I &Zoning Tree Administrator Project: gk(/�C. L.� Roman Public Works Public Utilities RDo P r N_ Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ['Approved. enied. ['Not applicable (Circle one.) Comments: BUILD G PLANNING &ZONING Date: 3/J?/20 Reviewed by: TREE ADMIN. Second Review: FrApproved as revised. ['Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES � PUBLIC SAFETY Reviewed by: /y' 1 Date: 3/18/2o FIRE SERVICES Third Review: Approved as revised. Denied. I INot applicable Comments: Reviewed by: Date: Revised 05/19/2017 r.. `' OFFICE COPY Revision Request/Correction to Comments **HIGHLIALL HIED I ON /` �Jr„ HIGHLIGHTED IN fs...i, City of Atlantic Beach Building Department GRAY IS REQUIRED. j 800 Seminole Rd, Atlantic Beach, FL 32233 � /\ 7 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: 60F7,..0-001 L. Revision to Issued Permit OR Corrections to Comments Date: 3,10/20 Project Address: to-lo Fla-7 Ct ` ��� Contractor/Contact Name: V.e\lQayVc' t y00t ( O A(Y\r_1�1G J ;" ( kso >---) Contact Phone: qoy coo 9-796 Email: ckynC1ry ck e 'fie ';c1„,1#f PO.i e1s,, (0 IM Description of Proposed Revision/Corrections: C. e. r-.' 1) ." S _L4_6 P-Le." Ad'('N'421'(n. k-SCDC:) ri n Cf @ *. I Amin^bt nig r ati S 0 rl affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • W'll proposed revision/corrections add additional square footage to original submittal? No ❑ Yes (additional s.f.to be added: ) • Will proposed revision/corrections add additional increase in building value to original submittal? IXNo ❑*yes (additional increase in building value: $ _7 ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: 7 (Office Use Only) L�Approved ❑ Denied ❑ Not Applicable to Department Permit Fee D e$ S19•dC.7 Revision/Plan Review Comments De.. ii -nt Review Required: �7.� Building / 2 , . ' : : Zoning Reviewed By Tree Administrator Public Works Public Utilities 3// /2C) Public Safety Date Fire Services Updatedl0/17/18 -, r r Je, OFFICE COPY CITY OF ATLANTIC BEACH }tl %' 800 SEMINOLE ROAD r? ATLANTIC BEACH, FL 32233 (904) 247-5800 1119' BUILDING REVIEW COMMENTS Date: 3/3/2020 Permit#: ROOF20-0012 Site Address: 670 PLAZA Review Status: Denied RE#: 171294 0000 Applicant: RELIANT ROOFING INC Property Owner: HAILEY GLENN Email:juliana@reliantroofing.com Email: GHAILEYHIGHLANDER@YAHOO.COM Phone: 9047123111 Phone: 7703147798 9047123111 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Non shingled roofs in Atlantic Beach go through plan review. 2. Submit 2 copies of the installation instructions and the Evaluation Report for the product approval number for the flat roof material. 3. Submit and highlight only the pages that are site specific for the installation of the product on this roof The Report is 106 pages, please only submit the pages pertaining to the install at this job. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us ern orited Gorr . te ' 3/V2-0 Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which OFFICE COPY ' Building Permit Application Updated 10/9/18 � ....-1'41161:1, City of Atlantic Beach Building Department **ALL INFORMATION N' 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED_ Job Address: 670 Plaza Atlantic Beach,FL 32233 Permit Number: I�CbF ©— Le al Description 30-94 17-2S-29E ROYAL PALMS UNIT 2 LOT 21 BLK 8 g p --� �_.-- RE# 171294-0000 Valuation of Work(Replacement Cost)$11340.00 Heated/Cooled SF Non-Heated/Cooled • Class of Work: ONew ❑Addition ®Alteration ❑Repair ❑Move ODemo OPool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial [1a Residential w • if an existing structure,is a fire sprinkler system installed?: ❑Yes MNo Z f!1 f% • Will tree(s)be removed in association with proposed proiect?❑Yes(must submit separate Tree Removal Permit).. I J Z ti Describe,In detail the type of work to be performed: J 0 O [L r,4 , - 1- reroof,22 sq,2/12 pitch,shingles FL10124-R21 &20sq flat section,using rolled roofing,GAF Liberty SBS FL5680-R20 n IA - d w.• O rrt `Z 1._ Florida Product Approval# FL10124-R21 & FL5680-R200 multiple products use product approval�ie�n() c ci O p Property Owner Information W H Qto Name Glenn Hailey Address 870 Plaza O 'x O Ci IAtiantic Flesch • tY._,,,..,,.•„� ,�,_,,,�,State FL Zip 32233 � � -_ Phone 770 314 7798 ----- - �^ - � (,) fn E-mail ghaileyhighlander@yahoo.com l.. Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) u.. S W Contractor Information Q V w w ?- Name of Company Reliant Roofing Qualifying Agent Cameron Shouppe UJ } ItL CO Addressi 4230 Pablo Professional Ct#155 Ci i Jacksonville State l Fl Zip!32224 -=• W a W Office Phone x4-657-0680 Job Site Contact Number 904-712-3111 N w W State Certification/Registration#-CCC1330615 . E-Mail amandalaareliantroofing corn > - — Architect Name&Phone# CC W CC Engineer's Name&Phone# Workers Compensation Insurer!Policy ft.VVC 19649225_ OR Exempt b Expiration Date 11/20/2020 Application is hereby made to obtain a permit to do the work and installations as Indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc, NOTICE:In addition to the requiremen permit,there'may be additional restrictions applicable to this property that may be found in the public recgr d,1 o t1 of 7 .--- F.,,, there may be additional permits required from other governmental,entities such as water management.districts;std I/ les,- V federal agertcie;. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. FEB 2 5 2020 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YQI�1 Tk p l i�l. :;i� �r�,lrtment TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY.B � p titf�rfi c Beach, FE_ RECORDING Y , TICE OF COMMENCEMENT. (Signature of Owner or Agent) (Signature on/•to ' `'' Signe and sworn to(K affirmed)before me this ),3 day of Signed and sworn to(or affirmed before me this day of v,bY 31tor) aj1Gy vet) , 2071),by i(t ' •II a. ..Tpt, "1'' AMANDA J A C eM"•••. ""'4' _,11141.•1111.`‘. _ ��• _State of Florida-Notary Public ignatureof 'otary) ,•MAN A JACKSON -1•�L�•�E Commission I GG 205328 �"'°�•' ,. • State of Florida-Notary Public %,M,,�Pc My Commission Expires ?:`�N4.c Commission#60205328 PersonaHTakhB®n2IlF2 Personally Known OR ;r..,.• �dc M Commission Expiros sa. ,w.,A—i►. [ 1 Produced Identification -1,?,;,';,,," y Apri109,2022 Type of Identification: t1�SiCh\N4 ire&ct\1, Type of Identification: , _ _ '_�_; OFFICE COPY NOTICE OF COMMENCEMENT !PREPARE IN DUPLICATE Permit No. goo-Pw!(310/Z Tax Folio No. State of Florida County of IQ LW 0..\ To whom It may concern: The undersigned hereby informs you that improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following Information Is stated In this NOTICE OF COMMENCEMENT. • Legal des iption of prope etn improved. —'• L 4 - I Address of property being improved G)--7--) az - 3 X33 General descrlptton of Improvements: Roof Replacement Owner C—,\ei-)n Address s 0 •"Lek/ - � o- Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor Reliant Roofing Address 4230 Pablo Professional Ct#155 Jacksonville FL 32224 Phone No.904-657-0880 Fax No. Surety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida.oiher!han nimsetf.designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided In Section 713,06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration.date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY ,/„.Q r / OWNER Signed›," E 2—k1-10 ; Before me this day or24 WO i1.1l1 :.• - Doc#2020033957,OR BK 19102 Page 824, C /or Duval.o a o!Fl.rfda.h:-pers•.: , : ��..• JACKSON Number Pages:1 himself,herself aro a.Irma!hat all.totems a . •-.f:.-I q Recorded 02/12/2020 10:34 AM, ere true and accurate • :� ° to rbf Florida NotetY public ;� � •? Commission#GG 205329 RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL �,,�,,, 'e`c My Commtsston Expires COUNTY :,;M;.d•' April 09,2022 RECORDING $10.00 ttj1`, ha'tiT�Pu' at large.St.t:a 7 County Hy corn on expires: --�6/ if pod .ent cation OMNI OFFICE COPY Category/Subcategory Manufacturer Product Description; Umitationof Use State# '` -fiat# C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles GAF Timberline HD Architectural FL10124-R21 2. Underlayments GAF Feltbuster FL18686-R1 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing GAF Liberty SBS FL5680-R20 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16.Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 10/17/18 OFFICE COPY In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name(Print Name):Cameron Shouppe *Contractor Signature: , *Company Name: Reliant Roofing *Mailing Address: 4230 Pablo Professional Ct #155 *City: Jacksonville *State: FL *Zip Code: 32224 *Telephone Number: 9046570880 *E-mail Address: amanda@reliantroofing.com Cell Phone Number: 9047123111 Fax Number: Page 4 of 4 Updoted 10/17/18 • OFFICE COPY Liberty TM SBS Self-Adhering Roofing System Information Sheet Updated: 9/06 REVIEWED FOR CODE COMPLIANCE CITY CF ATLA; TIC BEACH SEE FERIwITS FOR ADDITIONAL REO, IREIV. ' J CONDITIONS 0 n 17- 3/,&/2o EMAgar Quality You Can Trust Since 1886... From North America's Largest Roofing Manufacturer TM GAF MATERIALS CORPORATION 0 111114111 iiiii Liibiariltsor, GAF ERIALS CORPORATION SBS Self-Adhering Roofing System CORPORATION How Do I Prepare for a Liberty-Project? Before You Start...the installation of your new Liberty""SBS Self-Adhering Roofing,do the following: •Read Instructions Thoroughly...and understand how the entire system works before starting your installation. •Understand The Materials...know when and where to use each component,why each is necessary,and the common mistakes to avoid. •Contact GAF Contractor Services...at 1-800-ROOF-411 for detailed information on specific applications or consult the technical specification for detailed application instructions. Do's And Don'ts...Liberty"SBS Self-Adhering Roofing Systems are designed to be installed over low sloped roof decks. •Do Install On Roofs Between 1/2"And 6"Per Foot...and backnail the Liberty'Cap Sheet when the slope is greater than 1"per foot.Contact GAF Contractor Services at 1-800-ROOF-411 for fastening requirements specific to your project. •Do Install In Moderate Temperatures...between 45°F(7°C)and 95°F(35°C),to assure proper adhesion and easier work conditions. •Do Follow Proper Storage Recommendations...Keep material clean and dry.In cooler weather,24 hours prior to application store at 55°F(12.8°C)for best installation result. look for these important safety symbols •Do Install Over Clean Surfaces...that are free of dirt,moisture,debris,damage or are otherwise unsuitable for installation. •Don't Work Alone...GAF recommends between 2 and 4 people to install Liberty'SBS Self-Adhering Roofing. �—?/ Wear Glasses SAFETY FIRST...Protect yourself and others.Consider the following common sense safety precautions,including: •Wear appropriate clothing,including protective footwear,eye wear and gloves. 41 Wear Gloves •Be aware of your surroundings.Watch for power lines when working near ladders and use common sense on your jobsite. •Follow local building codes. Common •Bend at the knees.Never lift with your back. Mistakes Al and How to Precautionary Note: The application instructions for this product require the use of primers,adhesives or cements that contain Avoid Them solvents.Apply solvent-based products ONLY as instructed.Excess application of solvent-based products may affect the performance of this product,delay application of the cap sheet,cause surface blistering of the cap sheet or result in the asphalt flowing,dripping or staining.You may notice unpleasant odors from the solvents,which will dissipate when the solvent-based product has dried. What Tools & Equipment Do I Need to Install a Liberty'" Roof? 2t \ f 'oH u� Trowel Gloves Hammer Utility Knife Weighted Roller Brush Tape Measure Caulk Gun Liberty Installation Kit Liberty-Roof Materials... What Do I Need to Install a Quality Roof? •Liberty Installation Kit...comes with enough primer and cement to install approximately 200 square feet of membrane. Additional kits or extra primer and cement may be purchased if necessary. •Liberty"Self-Adhering Base/Ply...is the base weatherproofing layer when applied over acceptable,prepared decks or insulations.Each roll contains approximately 200 square feet. •Liberty"Mechanically Attached Base...is applied when the deck is unsuitable for self-adhered sheets or when a nailed base sheet is preferred.Each roll contains approximately 200 square feet. •Liberty-Self-Adhered Cap...is the first line of defense from the weather.Each roll contains approximately 100 square feet. •Metal Flashing...for covering roof perimeter edges.Metal flashings are typically sold in 10 foot sections and must be primed with asphalt primer and allowed to dry before installation. •Everything Else...when measuring,note the size and number of vent pipes,and other flashings.Don't forget any nails,lumber or other additional material that you may need. Liberty"Roof Systems... Which roof is righ - : 2-Ply Lay-out(SA Base) 2-Ply Lay-out(MA Base) 3-Ply Lay-out Ene PgN " - Mailable Deck Polylm AVReliable Deck ff� Insulation or 'girl �j �'��DenlDeon 'DereceerdaMbElla lap CMiL �� �.�.IrMln Side Lap 4/17 /iiri�WiiiE��p S L. ii1iTL ria i i •AAlWitilit_ or MI LIBERTY- LIBERTY- elan Medi" Liberty" 9 Ma. LIBERTY" LIBERTY' BASE/PLY SHEET CAP SHEET MA lase 5hee1 Cap Shell MEATY'MA BASE/PLY SHEET LM SHUT Note:Single Ply applic- a not shown;visit www.•- em for details if re•uired. OFFICE COPY STEP 1 - Preparing for a Liberty'" Roof... Is the Surface Ready? tr iii r •Remove All Existing Roofs...and determine the suitability of the existing roof deck.Alternately, . ? Liberty'MA base may be installed over certain roof types or deck types not listed.Contact GAF Contractor Services at 1-800-ROOF-411 for more information. 0 0 0 0 ! •Inspect The Deck...and determine what type of preparation is required.Replace damaged deck materials as necessary. •Install Insulation(if desired)...using GAF DRILL-TEC' screws and plates or GAF approved adhesives. o ° 1111 SI r Use minimum 1/2"thick EnergyGuard'"Polyiso insulation with approved fiberglass or paper facer. 1>11A' i- Acceptable Decks e e ° 15/32"Minimum Plywood Apply light asphalt primer at 1/2 to 3/4 gal per 100 sq.ft. GAF EnergyGuard Polylso Insulation Install Self-Adhered Liberty Base Sheet directly to insulation \Other Deck Types May Be Acceptable Contact GAF Contractor Services at 1-800-ROOF-411 for more information -0 0 0 0 o e e o Figure 2-1(Fastening) Common Mistakes(and How to Avoid Them)... •Poor Roof Drainage...can lead to leaks at the seams.Before installation,fix the roof deck at locations where water remains after 48 hours. Liberty*SOS cep She A •Not Priming The Deck...or metal may lead to poor adhesion and is a leading cause of problems. ;4° pmennOfLeaABeeter• •Not FollowingProper Stora a Recommendations...Be sure rolls are stored at 55°F for 24 hours prior Metrtxe2L)s0aCement Covering 9 P Tree Edge Beneath trmir to application. Clip Undeni0e Comer Al IS' STEP 2 - Installing Liberty" Base Sheet... nailed base or adhered base? AngleAtaliEndLaBs ;;= 1.Align Base Sheets...Starting at the lowest point of the roof where there are gutter or fascia edges,extend h raft 1' the base sheet over and down the fascia fully behind the metal edge or gutter height,fastened along roof ,, edge and along fascia 9"o.c.Minimum overhang is 1".Begin with 1/2 width(19 11/16")sheets in 2-ply ,* systems. _:: _ _ 2-2:: 2 _2--2 :-: __ 2 2 -- 1•T te- ctarting with 1/2 width(10 11/16")chootc to maintain tido lap ohheotc. —"401116.- and otaggor 2 rowo in tho fiold ovory 18"(Figura 2 1) Covor tho ontiro roof aroa. 0111111 ' �( 3.Install SA Base Sheet...by aligning sheets properly before removing the release liners.Roll out sheet a ll ll:Iris-Bed Of LeekBuuerm and let it sit or"relax"for at least 30 minutes to minimize the potential for wrinkles that can form during \�` Mates 1201 SOS cement installation.Remove one side of the release liner at a time. I� hill 4.Overlap Following Rows of Base Sheet...horizontally(side lap)by using the line found on the base ll sheet.Remove release films from top and bottom half of sheet in turn,carefully rolling back into position to maintain overlap Where no line is present,overlap by 3".Overlap vertically(end laps)by at least 6". Make sure all end laps are at least 18"apart. Figure 3-1 (End Lap) 5.Roll Base Sheet Into Place(SA Base Only)..,using a weighted lawn or linoleum roller.This improves adhesion to the deck and ensures properly sealed laps. Primed Edge Flashing.Min.4"Flap Set In Leak Busier"Matrix#201 SBS Cement ,Leak Buster.Matrix NOTE:A base sheet is not required;visit www.gaf.com for more information. 1201 OBS Cement Common Mistakes(and How to Avoid Them)... 041 •Not Letting The Liberty Sheets Relax...can lead to wrinkles.In colder weather,the rolls require more off Metal Cleat • i� Liberty'Dar awn Atime to flatten and return to adequate installation temperature. ,�/ •Not Rolling The Base Sheets...Is a leading cause of opening laps.Always pay close attention to laps when rolling the base sheets. 1-MIN ������ Lie SBSBuster.Ce NOTE:Never install wet or damaged material.Only install membrane when temperature is 45°F and rising. 1201 SOS cement Fasteners 2'0.C.Staggered STEP 3 - Installing Liberty'" Cap Sheet... Where Do I Begin? k�I���II� 1.Install Edge Flashing...over the base sheet in a 1/8"bed of cement and stagger nail with two rows of . Liberty-Base Sheet �� roofing nails,3"ac.Prime the face on the roof and allow to dry before installing cap sheet. 4Iki 2.Align Cap Sheet... 1/4"from the edge at the lowest point of the roof.Roll out and position full Pressure Treated Wood width(39 3/8")sheets with the selvage edge on the high side of the roof.Allow sheet to relax Nailer Mechanically Fastened Energ0Ouard"Insulation for at least 30 minutes prior to installing. Edge Flashing NI 3.Overlap Following Rows...horizontally(Side Lap)by aligning with the bottom of the selvage edge. 1Vertical(End Laps)must be overlapped by at least 6"and applied in a 1/8"bed of Leak Buster'Matrix" Shingleund\lament #201 SBS Cement.Make sure all end laps are at least 18"apart and have clipped corners(Figure 3-1). shingles GAF recommends installing a bead of plastic cement along the step up length of the lap. •4.Remove Release Films...from top to bottom half of sheet in turn,carefully rolling back into position to maintain overlap.Remove selvage edge release film prior to installing bottom half of sheet and Fastener finishing the side lap. apgrex.ro.c. 5.Roil the Cap Sheet Into Place...using a minimum 50 lb weighted roller.This improves adhesion to Lela,"y'" the base sheet and ensures properly sealed laps. Bashing must extendy Common Mistakes(and How to Avoid Them)... of lcoun, 01 shingles. •Not Priming the Edge Metal...can cause the cap sheet to peel away at the edges.Always prime \r edge metal before installing cap sheet. A rs •Not Applying Cement at the End Laps...Can cause laps to open.All locations where sheets extend Bpu�i" over granules must be set in cement. c Liberty'" Cap \ flashing must STEP 4 - Cleaning Up and Maintaining Your Liberty'" Roof... minmum;t 3 courses of Matrix"201 Premium •Remove All Tools and Materials From the Roof...and make sure there is no debris that can slow or shingles. SBS FIaMieg Cement Plywood Deck • ---- stop the flow of water •Dispose of Materials Properlyfollowing all federal,state and local laws. Shingle Tie-In •Inspect the Roof Annually...and remove any leaves,branches or vegetation that may be present.Look if C for other damage and repairif necessary. L,I3OIt •Keep Gutters Clean...to p ensure proper water flow and minimize the possibility of damaging ice dams. SBS Self-Adhering Roofing System ©2006 GAF Materials Corporation 9/06 RESLB108 r) Cash Register Receipt Receipt Number Z City of Atlantic Beach R12019 \ofiilr DESCRIPTION I ACCOUNT I QTY PAID PermitTRAK $169.48 ROOF20-0012 Address: 670 PLAZA APN: 171294 0000 $169.48 BUILDING $110.00 BUILDING PERMIT I 455-0000-322-1000 0 $110.00 BUILDING PLAN REVIEW $55.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $55.00 STATE SURCHARGES $4.48 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.48 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R12019 $169.48 Date Paid: Thursday, March 19, 2020 Paid By: RELIANT ROOFING INC Cashier: CT Pay Method: CREDIT CARD 2 Printed:Thursday, March 19,2020 10:11 AM 1 of 1 ti