2233 SEMINOLE RD UNIT 21 - ROOF20-0026 /4r1.-liirv, City of Atlantic Beach APPLICATION NUMBER
,i':
, ,� Building Department (To be assigned by the Building Department.)
800 Seminole Road �l
�' Atlantic Beach, Florida 32233-5445
O0 F w—CD Oa,
yr
Phone(904)247-5826 • Fax(904)247-5845
`r!J;19r E-mail: building-dept@coab.us Date routed: „S Zwir 411
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: Z2-37 C/Yt t.�O LG gp Department review required YrNo
uildin
Applicant: I [ flt,/V LL IL'�U Q p, AD c Planning &Zoning
Tree Administrator
Project: MO f RI Rooc= , Public Works
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLI ATION STATUS
Reviewing Department First Review: Approved. Denied. Not applicable
(Circle one.) Comments:
BUILDIN
PLANNING &ZONING Reviewed by: ! ' ' Date: f'2 `4:20
TREE ADMIN. Second Review:
Approved as revised. ❑Denie ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. I 'Denied. Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
Building Permit Application Updated 10/9/18
City of Atlantic Beach Building Department **ALL INFORMATION
i 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
is� IS REQUIRED.
Phone: (904) 247-5826 Email: Building-Dept@coab.us) �RD.'�Job Address: a3 3 St (€ �A lAI^-t i a` Permit Number: REZ0 ^ `-'oz�
Legal Description C'? -aS AC tt,e4n v;�l )')L CDaR0 Pihw)�)ktLI d-1) RE# j)& / 5) el — 0140
Valuation of Work(Replacement Cost J ' Heated Cooled SF N nn-FT JJa� �(o -�
( P )$ I� i O, C / o e�a�ed/Cooled
• Class of Work: ❑New ❑Addition ❑Alteration Repair ❑Move ❑Demo ❑Pool ❑Window/Door
• Use of existing/proposed structure(s): ❑Commercial [fesidential
• If an existing structure, is a fire sprinkler system installed?: ❑Yes Flo
• Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) ❑No 0
Describe in detail the type of work to be performed: / ' K 8/ o t.'74 ,ef,e,po)-o41 Lu
f /JS 4-a tl .A-."bA-Se64 oa-fi k''.P,dss ae j,r/G 6.4; C4( /; L13- Z cn CA
Florida Product Approval# for multiple products use product apprcJa I H
Property Owner Information �tti • O —
Name r 1 t� Ga r re-re- Address a -P 3 3 Sem( v101 IreO -= "'ie �
10-0-'71e— `= z 1.12
iO
oCity ► -I- rE -c. „ State F?— Zip 3,�-25"? Phone 61().-/ j-7 j C 3- -t 0
E-Mail 0 CC Z Ci
Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) G ex 0
Contractor Informationp0��f f-„ H
Name of Company 1 v1'e/ t )66 C. Qualifying Agent a W
Address 1-UZ S1 �(it.ct ( City J Q-'• 1��-h State moi— Zip 3aocc
Office Phone 'UI S (/4
l'l �' Job Site Contact Number 3 CI> n�' cC pgp
r.
State Certification/Registration# CC - l33Oft3�E-Mail pi0714-1-e---( FCC ivi&j & J}'Yls2(1 k cowl"I
w 553 w
Architect Name&Phone# 1 w 0 (/) W
Engineer's Name& Phone# 5 CC W
Workers Compensation Insurer OR Exempt o Expiration Date LU w
11 M
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public r13'p tyt
there may be additional permits required from other governmental entities such as water managementrMAI
geefederal agencies. R 8 (jOWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be donianCewitn au
applicable laws regulating construction and zoning.
BY:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
,-
RECORDING-YOU NgTICE OF COMMENCEMENT.
(Signature of Owner or Agent) (Signat(re of Contractor)
Si•ned and sworn to(or affirmed)before me this I fi day of Signed and sworn to(or affirmed before me this 1/- day of +
E M. •oEYby Err 1S1— Crt.rr er-e_ 11J1�,rTG� , ao 0.fM.AU /
iii i by �(Wie +€ (.
r o
1�. '1/ ' M C- 111.;1 '
My Comm.Expires 8/1 � , I),,t, '
i.:ommission No.GG135675 (Sigplg )�t41,(jINERNEY Notary Public,State o Florida /
Notary Public,State of Florida My Comm.Expires 8/17/21
My Comm.Expires 8/17/21
[ ]Personally Known OR ,^.a Ssion No.GG135675 ersonally Known OR Commission No.GG135675
[t,],P"roduced Identification Ivy [ ]Produced Identification
Type of Identification: r/- 7>r 1 v L,c4,44.4 Type of Identification:
a
CertainTeed El Technical Data
COMMERCIAL ROOFING SYSTEMS
FLINTLASTIC® SA JOB COPY
Self-Adhering SBS Modified Bitumen Mid Ply and Cap Sheet and
SBS Modified Bitumen Base Sheet for SA Roof Systems.
Product Flintlastic SA roofing membrane is a premium, self-adhering SBS modified bitumen roll roofing
Information material suitable for use in accordance with CertainTeed specifications for most low slope roof
system applications. Refer to the CertainTeed Commercial Roof Systems Specification Manual
for complete self adhered roof system specifications and application requirements.
d ' W
t` The Flintlastic SA line of products is more than a single membrane, it is a complete rc
; ` ^ system designed for base and cap or base, mid-ply and cap roof system configuration = ,,,r z 1.,
Use of Flintlastic SA Base permits complete mechanical attachment to nailable substr L Z 2
it 4
14
I preserving the integrity of the substrate for future tear-offs and adding additional water o �'r� o
f performance capabilities to the overall system. For larger industrial/institutional applicsdog�, I= z
a
Flintlastic SA Base, Mid Ply and Cap in combination represent a premium roof systemQaubla U ❑
I of meeting the performance criteria of a larger roof. Use of Flintlastic SA Base also ad�trtl ❑
fire resistance of the roof system, enabling UL Listing of the roof system. Z cc Z
UJNLL �
When using self-adhering roofing products, particular attention must be paid to storage F.. z
handling, deck preparation, slope and drainage, and application requirements to assurlDa L.L. 2 W
successful installation and long-term performance. u' 0 w w j:
CI >,.. a ac in
Compliances Flintlastic SA roofing membranes are manufactured on state of the art, dedicated roof it' IM o w
specifically designed for the production of modified bitumen roofing membrane, and rWePrN 2al w
, EEP AND004, exceed the following ASTM standards: > j
4o+�``` °�AF ASTM Standard CC w
'" Flintlastic SA Base D 4601, Type II
Flintlastic SA Mid Ply D 6164
Color Companion Products Flintlastic SA Cap D 6164
Classified by
tis Underwriters
~%5-
oJo Laboratories,Inc.
=F,,., Refer to the current UL Roof Systems Directory, or UL's web site, www.ul.com As to an External
1EF°o°yLry,60°-' for the most current information on UL listing for Flintlastic SA Products. Fre
i°°5 °°"
Flintlastic SA Base Flintlastic SA Mid Ply Flintlastic SA Cap Sheet FIintFlashTM SA
Roll Dimensions 66'6" x 39-3/8" 33'11" x 39-3/8" 33'11" x 39-3/8" 33'11" x 13-1/8" (or 9-3/4")
Thickness 1.5 mm 3.0 mm 4.0 mm 3.0 mm
Weight 84 lbs 68 lbs 97 lbs 22.5 lbs (or 17 lbs)
Coverage 2 Squares 1 Square 1 Square 1/3 Square(or 1/4 Square)
Top Surface Permanent Film Permanent Film Mineral-Variety of Colors Permanent Film
Bottom Surface Sand Removable Release Film Removable Release Film Removable Release Film
Reinforcement Fiberglass Mat Polyester/Fiberglass Polyester/Fiberglass Polyester/Fiberglass
Scrim Combination Mat Scrim Combination Mat Scrim Combination Mat
Tensile(lin) 65/40 (MD/CD) 80/60 (MD/CD) 80/55 (MD/CD) 80/60 (MD/CD)
Elongation(%) 6/5 (MD/CD) 50/55 (MD/CD) 50/55 (MD/CD) 50/55 (MD/CD)
Packaging Palletized, Bands Individual Cartons Individual Cartons Individual Cartons,
20 rolls per pallet 20 rolls per pallet 20 rolls per pallet 3 rolls per carton (or 4)
60 rolls per pallet (or 80)
Installation Refer to the CertainTeed Commercial Roof Systems Specification Manual for complete product
installation details and requirements. Below is a general guideline:
Deck Preparation
CertainTeed recommends the use of Flintlastic SA Base in conjunction with all self-adhering
membrane roof installations. Non-nailable roof decks may receive direct application of
r
Installation Flintlastic SA Mid-Ply followed by Flintlastic SA Cap provided the deck is thoroughly primed using Flintlastic SA
(cont'd) Primer. It should be noted without the use of a base sheet the membrane may be ifficult to remove if removal
is ever warranted, and certain UL and FM listings for the product may not apply.J 0 B COPY
Flintlastic SA Base �+
Nailable Substrates: Use standard nailing patterns and CT approved fasteners for attachment to nailable
decks. Nail base sheet every 9" o.c. on side laps and every 18" on center in 2 staggered rows in the field
of the sheet. Permanent top surface film is left in place.
Non-Nailable Substrates:Prime non-nailable substrates such as concrete using FlintPrimeTM SA at the rate of .20
—.25 gals/square. Allow primer to dry, maximum 4 hours. Apply base sheet using hot asphalt at the rate speci-
fied by CertainTeed. Insulation if used must be suitable to receive hot asphalt application such as FlintBoardTM
ISO Plus. Overlap base sheet sidelaps 3" and endlaps 4". Always start membrane application at the low point of
the roof and install all plies so that no laps are against the flow of water. Offset endlaps minimum 36".
Flintlastic SA Mid Ply
Apply to Flintlastic SA Base or suitable primed substrate overlapping sidelaps 3" and endlaps 6". Work with
lengths of Flintlastic SA Mid Ply appropriate for proper handling. Position and align cut lengths of Mid Ply,
staggering laps from the underlying base a minimum of 18" and offsetting endlaps 36". Once positioned, fold
back the membrane halfway lengthwise and remove the release film, then ease back into place. Or, lift the end
of the membrane and pull the split release film out as you walk the length of the membrane. Cut opposing
corners of endlaps diagonally to minimize "T" seam joints and seal using FlintBond SBS Modified Bitumen
Adhesive, trowel or caulk grade. Also apply a bead of FlintBond at side and endlaps. Use a heavy, weighted
roller to smooth and secure the membrane. Permanent top surface film is left in place.
Flintlastic SA Cap
Apply to Flintlastic SA Base and/or Flintlastic SA Mid Ply working with lengths of membrane appropriate for
proper handling and the same installation procedure as described for Flintlastic SA Mid Ply. Overlap sidelaps
4" and endlaps 6". Selvage edge with release strip is provided on Flintlastic SA Cap; position roll with selvage
edge at the high side of the roof. Once the first cap sheet membrane length is in place remove the top, sidelap
release film before overlapping the second length of Flintlastic SA Cap Sheet. Stagger sidelaps of Flintlastic SA
Cap a minimum of 18" from those of the underlying Flintlastic SA Mid Ply, and be certain endlaps are also
staggered minimum 36". At endlaps (or any overlap onto mineral surface), use trowel grade FlintBond Modified
Bitumen Adhesive uniformly in a 1/16" to 1/8" layer wherever an overlap exists to ensure an adequate bond.
Cut opposing corners of endlaps diagonally to avoid "T" seam joints. Use a heavy, weighted roller to smooth
and secure the membrane.
Verticals and Flashing Details
Vertical transitions and flashing details require a minimum two-ply detail using Flintlastic SA Mid Ply and
Flintlastic SA Cap, secured with Flintlastic Modified Bitumen Adhesive, trowel grade. FlintFlashTM SA pre-cut
flashing rolls can also be used in conjunction with flashing details.
Warranties CertainTeed offers a limited material Roof Membrane Warranty on Flintlastic SA roof membrane. Contact your
nearest CertainTeed office for additional information and requirements.
Technical CertainTeed provides technical assistance in the design, selection, specification and application guidelines
Assistance for all CertainTeed Commercial Systems. Architectural and field representatives are available for consultation
within each region.
Precautions Do not attempt application if ice, snow, moisture or dew are present. Surface to be bonded to must be clean,
dry and free from any dust or deterrent to adhesion. Ambient temperature must be 50°F or above. Do not
attempt installation on roofs without adequate slope and drainage.
Storage and SA rolls must be stored above ground, indoors, protected from the elements. Rolls that are improperly stored or
Handling have been on hand for prolonged periods of time may lose their tack. Do not attempt to install rolls that do not
exhibit an adequate bond.
CertainTeed El 750 East Swedesford Rd. West Region South Region North Region
P.O. Box 860 6400 Stevenson Blvd. 5525 MacArthur Blvd. Riverbridge Industrial Center
COMMERCIAL ROOFING SYSTEMS Valley Forge, PA 19482 Fremont,CA 94538 Suite 900 800 W. Front Street
(610)341-7000 (800)955-0811 Irving, TX 75038 Chester, PA 19013
www.certainteed.com Sales Support Group (800) 790-3347 fax (800)333-ROOF(7663) (866)297-ROOF(7663)
(800)233-8990 (972) 580-5645 fax (610)874-6170 fax
®2002 CertainTeed Corporation COMM-122
CertainTeed
SAINT-GOBAIN Technical Product Data
Commercial Roofing
JOB COP'LEANMOREA
FLINTLASTIC® SA CAP
SELF-ADHERING SBS MODIFIED BITUMEN CAP SHEET FOR SA ROOF SYSTEMS
Product Product Use: Flintlastic® SA Cap is designed for use as a cap membrane in multi-ply self-
Information adhered systems. It is suitable for use in the construction of various roof membrane
assemblies over a variety of substrates. It is intended for use over Flintlastic®SA NailBase,
Flintlastic®SA PlyBase or Flintlastic®SA MidPly.
Product Composition and Features: Flintlastic SA Cap is manufactured using a high performance,
stress-resistant polyester mat impregnated and coated with a superior grade of modified
bitumen compound. It is surfaced on the bottom with a removable release film and on the top
with mineral granules. The combination mat provides excellent tear and puncture resistance.
Roll Dimensions: 39%' x 32' 11"
Nominal Coverage: One square
Approximate Weight: 95 lbs.
Top Surface: Mineral granules
Back Surface: Removable release film
Packaging: Individual cartons (20 rolls per pallet)
Applicable Standards: Meets ASTM D6164, Grade G, Type I, D7505, D1970 and
CGSB 37 GP-56M Type 1a, Class A, Grade 1, ICC-ES (ESR-1388), Miami-Dade, 000°�
Florida Buildng Code Statewide Approval (FL 2533 and FL 16709)and Texas CR C
Department of Insurance (RC-47). Flintlastic SA Cap White is an approved
ENERGY STAR. product for slopes greater than 2"/12". Initial Solar Reflectance:
0.27; Aged Solar Reflectance: 0.24; Thermal Emittance: 0.89. Flintlastic SA Cap
White is also listed by the Cool Roof Rating Council (CRRC). The CRRC product
code ID is 0668-0018.
Technical Modified Bitumen Coating: Non-oxidized (flux)asphalt, blended with elastomeric
Data styrene-butadiene-styrene (SBS) polymer.
Support Mat:High performance, stress-resistant polyester mat.
Test Description Test Method Results*
Solar Reflectance Index(SRI): ASTM E1980 28/24
Tensile Strength: ASTM D5147
@ 73.4+/-3.6°F MD/XD 80/55 lbs./in.
@ 0+/-3.6°F MD/XD 115/90 lbs./in.
Elongation: ASTM D5147
@ 73.4+/-3.6°F MD/XD 60%/65%
@ 0+/-3.6°F MD/XD 40%/40%
Dimensional Stability: ASTM D5147 0.5%
Low Temperature Flex: ASTM D5147 Pass @ 0°F
Thickness: ASTM D5147 4.0 mm(160 mils)
Tear Strength: @ 73.4+1-3.6°F MD/XD 110/80 lbs.
*NOTE:Published results are nominal production values confirmed by independent laboratory testing.
MADE IN
U.S.A.
JOB COPY
Product Installation:Apply to Flintlastic SA NailBase, Flintlastic PlyBase and/or Flintlastic SA MidPly
Application working with lengths of membrane appropriate for proper handling and the same installation
procedure as described for Flintlastic SA MidPly. Overlap side laps 3"and end laps 6".
Selvage edge with release strip is provided on Flintlastic SA Cap; position roll with selvage
edge at the high side of the roof. Once the first cap sheet membrane length is in place,
remove the top side lap to release film before overlapping the second length of Flintlastic SA
Cap. Stagger side laps of Flintlastic SA Cap a minimum of 18"from those of the underlying
Flintlastic SA MidPly and be certain end laps also are staggered minimum 36". At end laps
(or any overlap onto mineral surface), use trowel grade FlintBondr modified bitumen adhesive
uniformly in a '/,6"to '/8' layer wherever an overlap exists to ensure an adequate bond. Cut
opposing corners of end laps diagonally to avoid "T" seam joints. Use a heavy, weighted roller
to smooth and secure the membrane.
Deck Preparation: CertainTeed recommends the use of Flintlastic SA NailBase in conjunction
with all self-adhering membrane roof installations on nailable substrates. Non-nailable
roof decks may receive direct application of Flintlastic SA PlyBase or Flintlastic SA MidPly
followed by Flintlastic SA Cap, provided the deck is thoroughly primed using FlintPrime®SA.
It should be noted that without the use of a nailable base sheet, the membrane may be
difficult to remove if removal is ever warranted and certain UL listings
for the product may not apply.
Precautions: Flintlastic SA Cap must be applied as part of a self-adhered system. It is not
intended for use with hot asphalt, cold adhesives or torch-down applications. Roof decks
must be structurally sound, dry and smooth, and meet or exceed minimum requirements
of the deck manufacturer, local code and CertainTeed. Don't attempt application if ice, snow,
moisture or dew is present. Surface to be bonded to must be clean, dry and free from any
dust or deterrent to adhesion.Ambient temperature must be 50°F or above. Don't attempt
installation on roofs without adequate slope and drainage. Additional specifications and
precautions are contained in the CertainTeed Commercial Roof Systems Specifications.
Storage and Flintlastic SA rolls must be stored above ground indoors and protected from the elements.
Handling Rolls that are improperly stored or have been on hand for prolonged periods of time may lose
their tack.Do not attempt to install rolls that do not exhibit an adequate bond.
Warranties CertainTeed offers Limited (product only) and No Dollar Limit (NDL, product and
workmanship)warranties. Warranty type and duration is dependent on roof system
configuration and contractor selection. Only CertainTeed Gold and Silver Star Contractors
are eligible to apply for NDL warranties on specific roof projects. For more information,
see CertainTeed Commercial Roof Systems Specifications or contact Commercial Roofing
Technical Services.
Technical CertainTeed provides technical assistance in the design, selection, specification and
Assistance and application guidelines for all CertainTeed Commercial Systems. Architectural and field
representatives are available for consultation within each region. For more information,
Services contact CertainTeed Commercial Roofing Technical Services at 800-396-8134 x2.
_n f , IN CertainTeed Corporation
Du ROOFING • SIDING • TRIM • DECKING • RAILING • FENCE • GYPSUM • CEILINGS • INSULATION
SAINT-GOBAIN 20 Moores Road Malvern,Pa 19355 Professional 800-233-8990 Consumer 800-782-8777 certainteed.com
07/17 CertainTeed Corporation,Printed in the USA,(ode No.COMM-169