Loading...
1600 SELVA MARINA DR - MECH20-0003 i.Aii;y,, City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) A. 800 Seminole Road ` .� Atlantic Beach, Florida 32233-5445 hi\�L. CCD- 0003 � � Phone(904)247-5826 • Fax(904)247-5845 3 J;ilr'' E-mail: building-dept@coab.us Date routed: t CO/ Z 0 Z.C.) City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: \r(, Do 2 EL-u la IVl c V-4.Nn Department review required Yes No Applicant: I E-17k k E1.V(,CC Planning &Zoning Tree Administrator Project: R EP-• _O ) 3 -k) Ems. Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protectionii Florida Dept.of Transportation „,(\� St.Johns River Water Management District V .Army Corps of Engineers 0,-,t Division Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Nf4Approved. I (Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: �. k Date:4 f D Z ToZO i 1 TREE ADMIN. Second Review: Approved as revised. I (Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. Denied. Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 C; I l y.0 dtAAct) ®fecfrixServci c Mechanical Permit Application **ALL INFORMATION , 4,- HIGHLIGHTED IN J� ��{' City of Atlantic Beach Building Department GRAY IS REQUIRED. r *, M=as �n 800 Seminole Rd, Atlantic Beach, FL 32233 rn 210 _ 00 07: ,'�'="'" Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: JOB ADDRESS: 1600 Selva Marina Drive Atlantic Beach,FL 32233 PROJECT VALUE$4,200.00 NEW AIR CONDITIONING &HEATING SYSTEM INSTALLATION ARI#(REQUIRED) ❑Air Handling Equipment Only p Condenser Only ❑Air Handling Unit& Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: Unit Quantity BTUs per Unit 4,s0o Seer Rating (REQUIRED) Duct Systems: Total CFM [REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED) ❑Air Handling Equipment Only ❑ Condenser Only p Air Handling Unit& Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating(REQUIRED) Duct Systems: Total CFM nFIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of pla EC E IVE Commercial Hoods Quantity (Requires 3 sets of pla s Fire Suppression Systems Quantity (Requires 3 sets of pla MAR 16 2020 FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace (Qty) Automobile Lifts BY: Gas Piping Outlets Boilers BTUs Elevators/Escalators nALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTUs g(9100 #Water Heaters Solar Collection Systems Tanks (gallons) Wells (-J OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Name:Atlantic Beach Country Club Inc Phone Number: (904)372-2222 Mechanical Company: Tech X Services,LLC Office Phone: (904)356-9333 Fax(904)384-2610 Co.Address: 525 Stevens Street City: Jacksonville State: FL Zip: 32254 License Holder: Wesley Shawn Feagle State Ce ification/Registration# OAC058350 Notarized Signature of License Holder1) J, , _afeThe foregoi 'nstrument was acknowledged before this 1 ) day of,'s� II rdn ,20 ' the state o Florida, County of _ � n,..., ignature of Notary PublicCia (�J J �`.PR`vie, ALEXANDRA SHIRL PARTRIDGE �° `r', Notary Public H. State of Florida '+ Commission GG 057351 Personally Known OR [ 1 Produced Identification ���,�.� ',,� My Comm.Expires Dec 21,2020 pe of Identification: ,,° �.``� Bonded through National Notary Assn. updated 10/9/18 e C - • NO q 1 / 727 2"`�Street Hudson,Wisconsin 54016 Quotation • ® 800-955-5253 Quote No. NL1992253NN-A 715-386-2323 Date: 11/14/2019 • • �� 715-386-6149 FAX Page: 1 of 3 • • • Customer TriMark Strategic-Florida 31470 ABC CPG STRA I 0 --') 6._, 1461 S Beltline Road, Suite 10 -+ Coppell,TX 75019 Attention g ,ri , - " Project Atlantic Beach Country Club Item Number Rep Name 63-Unisource Marketing Group Rep Number 63 nv Sales Specialist Gayle Gerhardt / ork Approved by: _Gayle -V#127709- FWR1992253 - Sales Order 182497 ( va California State Contractor License#940932. A!' •� (1) Nor-Lake FINELINE Walk-In Cooler `� L�14'0"long,8'0"wide,8'7"high. Ao' Finishes: _'E^'/�� C 26 Gauge Corrosion Resistant Stucco Embossed Coated Steel-Interior wall, Exterior wall 040 Stucco Aluminum-Interior ceiling 26 Gauge Smooth Galvanized-Ceiling topside, Floor bottomside • .100 Smooth Aluminum-Interior floor 14'0" • r r V/////////Y///////////zz/////Y/////////////////////////////////// a ) ) ) ) 6, n 6 N 1 V rlI / / Cooler(35.0°F) / / 0 8'7"high .--M--' / / With Floor / / / / 1 / s Or Ttiis walk-in is designed and fabricated in accordance with State of Florida Approval. FL6080-R4 A.lire%. CO N The exposed sides(not adjacent to the building wall)of the walk-in require a 6" MINIMUM edge from face of panel to face of concrete to maintain approval. VO ___ 1\\\N (, (g MOO SENT lb P 0-0,11 119S tQ6 — FF O,o 'CE COPY f- Approved By Permit Desk Building Department City of Atlantic Beach, FL . ., • • NO��I K/E 72Hu7 2'dsod eet nsin Quotation n,Strisco W54016 • ® 800-955-5253 Quote No. NL1992253NN-A • • %.--N 715-386-2323 Date : 11/14/2019 715-386-6149 FAX Page: 2 of 3 Customer TriMark Strategic-Florida 31470 ABC CPG STRA 1461 S Beltline Road, Suite 10 Coppell,TX 75019 Attention Project Atlantic Beach Country Club Item Number Rep Name 63-Unisource Marketing Group Rep Number 63 Sales Specialist Gayle Gerhardt Outdoor Walk-In includes Flat White Membrane Roof With Trim—45 Lbs./Sq. Ft. Ceiling Load Capacity Minimum.S3-1 X(1)36"X 78"Walk-In Door left-hand swing (4' Dw-ae—O-� '4' i 4oOi-1 �fncludes door closer,cam lift hinges(one spring loaded on 36"wide and smaller doors), NL9800 deadbolt key/padlock handle with inside release,magnetic gasket,heater wire,double sweep gasket, LED vapor proof light, Heated Air Vent(standard on all freezer compartments)and NL508 combination digital thermometer and switch w/pilot light. (106"Interior Ramp With Non-Skid Strips Applied To Top(24"Deep) (1) NASJ75RL4-&BYH 35°F Operation, High Temperature, Air Cooled, R-449A, Refrigerant,"Off Cycle"Timer,Remote Refrigeration System, See NorLake.com for Spec Sheet and Electrical Data (system capacity 7007 BTU's/hour at 100.0°F ambient temperature.) Calculated load for Cooler(35.0°F)is 4992 BTU's/hour calculated from 100°F ambient temperature,0'elevation, 70°F floor temperature, 16.20 minutes open door time per 24 hrs for(1)36.00"X 78.00"walk-indoor opening into 100.00°F ambient, 1.5 Watts per square foot lighting operating 8 hours per day,0.056 occupants working 8 hours per day.All calculations are based on data supplied by ASHRAE publications. (1) UL Listed All Weather Hood And Rack With Dade County Approved Stand,Remote (1)OF to-20F Ambient Control Kit (Includes Head Pressure Control And Crankcase Heater) (1) Prepiped Remote Refrigeration System Includes Drier, Sight Glass, and Hand Valves Installed On Condensing Unit-TXV And Solenoid Installed On Unit Cooler (1)75 Series-Optional Five Year Extended Compressor Warranty (1) 18 Month Labor/Service Warranty Refrigeration is"sized"for holding product only; that is;our calculation is based on product entering at the same temperature as the desired temperature of this walk-in. If you feel that this is insufficient, please advise. (1) This walk-in is designed and fabricated in accordance with State of Florida Approval. FL6080-R4 Approval. Construction Approvals: NSF Approved,cULus and CSA Electrical, UL Flame Spread-25 and ULC Flame Spread-50 in accordance with ASTME-84.To comply with the US Energy Independence&Security Act of 2007,all walk-in doors opening into the ambient(indoors or outdoors)are required to have a method for minimizing infiltration when the doors are open.All Nor-Lake walk-in doors will include a spring hinge to comply with this standard by 1-1-09, however;to further minimize infiltration, Nor- Lake recommends the use of a strip curtain or strip door for all exterior doors. NOTE: Indoor walk-in(s) must be in an environmentally controlled space. Relative Humidity should be kept between 30%-60%, maintaining a Dew Point of 50° F or less. Quotation is subject to change upon receipt of detailed specifications and/or refrigeration load information. Refrigeration sizing is based on maximum line runs of 100 feet per system. NOTE:Walk-Ins sold into the state of California may require structural engineered drawings for seismic review. If required, Nor-Lake can provide the required drawings and structural support.Please contact Nor-Lake for lead time and pricing to meet this requirement. Local Codes:Walk-Ins may need engineered drawings or special construction to meet local code approvals for rain,wind,seismic, and snow load approvals. If required,please contact Nor-Lake for lead time and pricing to meet these requirements. This walk-in is designed and fabricated in accordance with State of Florida Approval. FL6080-R4 Approval. VC? The exposed sides(not adjacent to the building wall)of the walk-in require a 6"MINIMUM edge from face of pan iti9p of - concrete to maintain approval. Building wall must run adjacent to long wall(14')of walk-in cooler per State of Florida Approvals. Door with Interior Ramp must open into building wall per State of Florida Approvals. O .oy General arrangement , Project: 182497-1 Atlantic Beach Country Club Sales No:18 7=t Customer:TriMark Strategic-Florida Date:11 19 Cri) a n J 14'0" O 1'0' 4'0" 4'0" 4'0" 1'0" or 142497-1 2 182497-1-5 182497-1-5 182497-1-50•141 la' 182497-1-2 1 0 0 n r . m O ti N cn N OD N CO r,_ 4 n / / / / _ o Cooler(35.0°F) / / in 8'7"high .4--20-- / / o / / N c With Floor / co o rn // / N / vCO il .' This walk-in is designed and fabricated in accordance with State of Florida Approval. FL6080-R4 Approval. b ti IT: = N p r- ., .- O 4 1'0"131.,_ ',,fiI_� 4'0" 4'0" 4'0" 1,0" 182497-1-5 182497-1-5 182497-1-5 1 2497-1-2 Page 1 of 3 Ceiling arrangement A Project: 182497-1 Atlantic Beach Country Club Sales N.2497-1 Customer: TriMark Strategic-Florida Dat: 412019 r 4.0' 2'0" O 4'p" 4'p., J a DV Da I:6 la D h.-8) ® c0® 6)® ® O® m t- n a) N co d CO co co N G CO G O ilD zo ao m EB , ® CD ® ® ® ® G 4'0" 2'0" 4,0" 4'0" a ea Da va ,I Page2of3 Floor arrangement Project: 182497-1 Atlantic Beach Country Club Sales N 97-1 Customer:TriMark Strategic-Florida Date: 1412019 4'0" 2,0„ 4,0" a 0a 40„ " a ® N ® co ® ® v T7 t P- r r CO CO CO CO r ,- r ED O ao 2 u- 2 ti g ti- Eop a 9 a 4'0" 2'0" 4'0" 4'0" l'i 4(1 Dla Page 3 of 3