Loading...
1977 BEACH AVE - ACRS20-0074 f City of Atlantic Beach APPLICATION NUMBER A • ,,0„ Building Department (To be assigned by the Building Department.) 1- 800 Seminole Road y C D l/�?4 . . . ¶ Atlantic Beach, Florida 32233-5445 �`SZ0- Phone(904)247-5826 Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l `77 �EAC(4 LV e._ Department review required Yes No ^ ' P(LgiToning Building Applicant: F CL 3 pe�t.cd Tree Administrator Project: P / C ._Lo sr,Liggtlic Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature If Other Agency Review or Permit Required Review or Receipt Date (C/ of Permit Verified By 5 � Florida Dept. of Environmental Protection (��� P'� Florida Dept. of Transportation �v St. Johns River Water Management District v 4 Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: iKoproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING y y •ll�V Reviewed b Date: TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. ❑Denied. Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 J O B car?' **ALL INFORMATION I O Mechanical Permit Application HIGHLIGHTED IN • City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 AL 10 0074 "" Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: JOB ADDRESS: / 97?f1'z& ' d T�`„ ri' ,89;-6i4 PROJECT VALUE$ 4 e i - ' N NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED) ,20/$768-66 0 Air Handling Equipment Only ❑ Condenser Only _ 6d Air Handling Unit& Condenser Air Conditioning: Unit Quantity / Tons per Unit 3/viii 1/2u12/(J)lN Heat: Unit Quantity BTUs per Unit ?G Aro . Seer Rating (REQUIRED) l'7' 75 Duct Systems: Total CFM /,_CrC REPLACEMENT AIR CONDITIONING& HEATING SYSTEM INSTALLATION ARI N(REQUIRED) ❑ Air Handling Equipment Only ❑ Condenser Only ❑ Air Handling Unit& Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating(REQUIRED) Duct Systems: Total CFM Li U FIRE PREVENTION Zm N Fire Sprinkler System Quantity (Requires 3 sets of plans) J Z O Fire Standpipe Quantity (Requires 3 sets of plans) n',:.-. U Underground Fire Main Value (Requires 3 sets of plans) LLI O 1.=. Z w Fire Hose Cabinets Quantity (Requires 3 sets of plans) 0 al a p 1... Commercial Hoods Quantity (Requires 3 sets of plans) 00c.“,) U c. V p Fire Suppression Systems Quantity (Requires 3 sets of plans) p cc ._ FIRE PLACES MISCELLANEOUS: 0 J N h pl. Fireplace (Qty) Automobile Lifts O Q s w Gas Piping Outlets Boilers BTUs li I" Elevators/Escalators Ca ® w wa ¢ m W > m ALL OTHER GAS PIPING Heat Exchanger N.. w a Quantity of Outlets Pumps U cr) w #Vented Wall Furnaces Refrigerator Condenser BTUs j cc w #Water Heaters Solar Collection Systems L iii Tanks (gallons) Wells LJ OTHER: Permit becomes void if work does not commence within a'six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Name: ._i ._ jiIMIII *Iljt4I(1 IKa& F.__- Phone Number: e1f1`1-57/ _07ele8i Mechanical Company: - S p e ,e i cc i ( i V S-E r1 L° Office Phone:clog -5 7 1 ©7 YS�Fax Co.Address: 1 ' 7 (-0 q c.0 a!t ' City:OtZuelp Pct&K State: PZ Zip: 3.A0 Cc License Holder: a ► " i vx I * o I S to Certification/Registration#C/16 1 F 13 7 c'3 Notarized Signature of License Holder 1' J The foregoing_instrument was acknowl:died be ore me this da f /n arc k ,200/0, in the State of Florida, County of r V,._ .JJ ignature of Notary Public _ A 7611-4f1) ) w• SHANNON TORRES [ 1 Personally Known OR Produced Identification 14"Lt ' ;:Commission#GG 095440 Type of Identification: cls — S S 3D---(3 p- Sy - 3 2 `t-0 ���, -2c.� 5 ' Updated 10/9/18 • r -..7;:-..,-, 'l' Expires April 30,20't1 $,•,F,`.1P' Bonded Thru Troy Fain Insurance 800-385-7018 4 JOB COPY Martin Residence HVAC Load Calculations for Martin Residence 1977 Beach Avenue Atlantic Beach, FL 32233 601 /*WIN RHVACRESIDENTIAL HVAC LOADS Prepared By: Greener Solutions Air 4453 Sunbeam Rd Jacksonville, Fla. 32257 904-730-3313 Thursday,January 23, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. • Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. • Greener Solutions Air Martin Residence Jacksonville,FL 32257 Page 2 Project Report 'General Project Information Project Title: Martin Residence Designed By: Lyle Guyer Project Date: Friday, January 17, 2020 Client Name: Martin Residence Client Address: 1977 Beach Avenue Client City: Atlantic Beach, FL 32233 Company Name: Greener Solutions Air Company Address: 4453 Sunbeam Rd Company City: Jacksonville, Fla. 32257 Company Phone: 904-730-3313 Design Data Reference City: Jacksonville Mayport Naval, Florida Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 16 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 39 36.58 n/a n/a 70 n/a Summer: 92 78 54% 50% 72 64 Check Figures Total Building Supply CFM: 661 CFM Per Square ft.: 0.428 Square ft. of Room Area: 1,545 Square ft. Per Ton: 564 Volume(ft3): 14,290 Building Loads Total Heating Required Including Ventilation Air: 16,756 Btuh 16.756 MBH Total Sensible Gain: 20,390 Btuh 85 % Total Latent Gain: 3,683 Btuh 15 % Total Cooling Required Including Ventilation Air: 24,072 Btuh 2.01 Tons (Based On Sensible + Latent) 2.74 Tons (Based On 62%Sensible Capacity) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Thursday,January 23,2020, 11:31 AM Rhvac-Residential&Ught Commercial HVAC Loads Elite Software Development,Inc. Greener Solutions Air ■ Martin Residence Jacksonville,FL 32257 Page 3 Load Preview Report Net Rec ft.2 Sen Lat Net Sen Min Min Sys Sys Sys Duct Scope Ton Ton /Ton Area Gain Gain Gain Loss) Htg Clg Htg Gg Act Size CFM CFM CFM1 CFM CFM Building 2.01 2.74 564 1,545 20,390 3,683 24,072 16,756 416 661 416 661 661 System 1 2.01 2.74 564 1,545 20,390 3,683 24,072 16,756 416 661 416 661 661 9x9 Supply Duct Latent 229 229 Return Duct 783 289 1,071 283 Zone 1 -Clg.:52%, Htg.:65% 911 10.695 1,973 12,668 10.656 269 360 269 360 360 7x7 1-Kitchen 176 4,498 416 4,914 2.125 54 152 54 152 152 6--2 2-Living 364 4,533 942 5,475 5,266 133 153 133 153 153 6--2 3-Office 250 1,663 615 2,278 3,265 82 56 82 56 82 3--2 4-Bathroom 1 121 0 0 0 0 0 0 0 0 0 1--0 Zone 2-Clg.:48%, Htg.:35% 634 9,992 1,192 11,184 5,816 147 337 147 337 337 7x7 5-Master Foyer 300 6,046 419 6,465 3,731 94 204 94 204 204 7--2 6-Master Bath 149 0 0 0 0 0 0 0 0 0 1--0 7-Master Room 186 3,946 773 4,719 2,085 53 133 53 133 133 5--2 Sum of room airflows may be greater than system airflow because system has multiple zones and system room airflow option uses the greater of heating or cooling. Thursday,January 23,2020, 11:31 AM • I0 "I JOB COPS , : - • 4 i eee ,. ei Ili Ifu • o u II '�`—' I 1 ; e� litII t _„ lor 11 ro .s !jji7• r .4, r-rs: u ;,,, 1 1 • 1A 1 1 CEI cm. • II 0 • 11 II 11 1 11 la list li inc2=Fii -1 C., 4 A 111114tho 1 111 ii! R` fit. f .......A • I r-- 1� Iii 111 _i______4r,„.„, rek- .---i ri E �� -, } it i I_ .. � _� • © 1 Q A.\ obi IF •., q t. if 4 �� _!tel a . . . . T