705 ATLANTIC BLVD #30 - MECH20-0002 • City of Atlantic Beach APPLICATION NUMBER
. d Building Department (To be assigned by the Building Department.)
A ): 800 Seminole Road c n
so Atlantic Beach, Florida 32233-5445 �l � 000Z.
1i r
Phone(9 )247-5826c Fax(904)247-5845
E-mail: building-dept@coab.us Date routed: ` G
Z-C-)
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: /0 S jTLAvYcc e LVD Department review required Yes No
uilding
Applicant: C , L l (YM Planning &Zoning
Tree Administrator
Project: 4 ( r, DJ C.NQ..ES Public Works
Public Utilities
l(/\. K Ek)D C bi OCL-Pc—CG s (*Df'f Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection @e"
Florida Dept. of Transportation V
St.Johns River Water Management District `
Army Corps of Engineers Jj
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: Date:
TREE ADMIN. Second Review: A roved as revised. Denied.
❑ pp ❑ Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. I JNot applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
Mechanical Permit Application
**ALL INFORMATION
�� HIGHLIGHTED IN
City of Atlantic Beach Building Department GRAY IS REQUIRED.
800 Seminole Rd, Atlantic Beach, FL 32233 f\,i Lc-Li _000Z
Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#:
JOB ADDRESS: -3D 6 ia ikt PROJECT VALUE $ ,; 000
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED)
❑ Air Handling Equipment Only ❑ Condenser Only ❑ Air Handling Unit& Condenser
Air Conditioning: Unit Quantity Tons per Unit
Heat: Unit Quantity BTUs per Unit Seer Rating (REQUIRED)
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI#(REQUIRED)
❑ Air Handling Equipment Only ❑ Condenser Only ❑ Air Handling Unit& Condenser
Air Conditioning: Unit Quantity Tons per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating (REQUIRED)
Duct Systems: Total CFM
FIRE PREVENTION ''"'ery� tq'—gpVE
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans) ft A
MAR 1 1 2020
Undergr and Fire Main Value (Requires 3 sets of plans) g 1
Fir ose Cabinets Quantity (Requires 3 sets of plans) Ent
ommercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace (Qty) Automobile Lifts
Gas Piping Outlets Boilers BTUs
Elevators/Escalators
HALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTUs
# Water Heaters Solar Collection Systems
( Tanks (gallons)
Wells 1 , r 7
I (OTHER: i 1 'lell . k - .) ►. r1► X ' , I t"4�.. til.C6
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby
certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this
work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or
local law regulation construction or the performance of construction.
Owner Name: Phone��"" Number: y'
Mechanical Company: et M A-1/6. (AJ& Office Phone:5(O ' )yo) r ilz6 a
Co.Address: 02 i 21 6d 0\1 C.(e_ -e... City: ...S-AX State: t L Zip: 32,2.2,5
License Holder: Loy LI p. C4/�feaxiState Certification/Registration# C /1G X8136 0 '
Notarized Signature of License Holder Art, .e�,.---
The forego' ' strumen-was acknowledged before me his 0 da . ' a 0 6 •n the State of Florida,
1 ounty of V' V
;otiv . DONNA T.BIS50N
Signature of Notary Public 641,14?� ;�' Notary Public-State of Florida
,I A? commissionsGG913488 [ ] Personally Known OR [ ] Produced Identification
'?�n My Comm.Expires Oct 17,2023
Bonded through National Notary Assn. Type of Identification:
Updated 10/9/18
BSSM 48-4 ETL B55AEWD
vNDFlF NEW DETAIL
I.e.,.
STAINLESS STEEL EXHAUST HOOD WITH MAKEUP AIR VENT pp 21'
ETL APPROVED. N.S.F.LISTED.CONFORMS TO NFPA 96 E�� V.Pus
~— --ID %/I
ETL LISTED#3148390 CONFORMS TO UL STD 710 NFPA. 18' 9.5'
4. I
PROFILE VIEW-TYPICAL HOOD SYSTEM INSTALLATION II Jr } jFM1,1 15i FAN S
Mns.,rAIR FMI -
L._____2,
0•04 85
71111[- �4❑ I 10'MIN I `� + I
// `` 24• X5.25•+ 0
_ HINGE IIT / \
MIN.2G'iALL •
iA GLRB 12• `/ O
ROOF 'i�rr¢'utL .
l ] 1 ,�z,1' i,,,,,..,....., w
it AFxV,r'/ GALVANRED .3.-
,.......„... ~8"—4. Y X
MAI:DEAIR ' b' U Q
AILS r�LI UIP TIGHT WE M t
GREASE pI(,T D
LIDUIO TIGHT WELDED 51' --..: N F-
A Ar •-1 BSSM � 14 '46
t.., rn / No. • PLAN VIEW DETAIL 48•
l b 01 MDMIVIr'CR&F.-. t. ' CC
O
1 �� / wr[cRnrtos.rr.Nur I LU i�-10.5'i Q
RN
0
IA ArrVITE
ucwL=rte OPTIONAL // 21• 11.1
tri,Eanla EXHAUST / 105' 18. u) O
/ ^�r (TR Of al ` COLLAR // I
Bnrr a /FM•/' /
--
INCANDESCENT f J
LIGHT FIXTURE 10- 4r SI' N W
INSTALL IN ACCORDANCE \._____..--1 I H
1/111/14414
j, „ WITH NFPA 96°AS WELL AS
ALL STATE&LOCAL CODES }
~�,...22,,INNLEE,
O»tort Fawn
mL 1t 191.5'
(---- X t41
I
RV'TIF
OPTIONAL
SUPPLY COLLAR/ —16'—►
FIRE DAMPER
_ HOOD INFORMATION(PER HOOD)
HOOD FILTERS LIGHTS
'YP.COOKING EQUIPMENT MODEL LENGTH WIDTH HEIGHT CONSTRUCTION
TYPE QTY HEIGHT LENGTH QTY TYPE
TYPE:430 ALUMINUM
555M48-4-ETL 41 48" 24" STAINLESS STEEL BAFFLE 1 16" 20" INCANDESCENT
GAUGE:IB
w/HANDLES 1 LIGHT FIXTURE
•
POLISH:A3 UL APPROVED 1 16" 25" UL APPROVED
CFM REQUIREMENTS(PER HOOD) OPTIONAL COLLARS(PER HOOD)
///� /�/��/ � ��i%/i/��j�j A � EXHAUST SUPPLY 0 EXHAUSTSZEQTYSIZE
STANDOFFNONENOM WEIGHT ACCESSORIES
1,120 CF.75 Sr. 896 IP.12 S.P. ❑ 200 LBS
® 3"
1 10.5"X10.5" 1 16"X10" r_,
A,&V-6) 3--V .�o0-30 1..)Q 43-)O
..D./-?0, g/ 1 crtt_- b 1 -scol ti c-Q°-)11
. . • . , •• . • . . .
.\ -
Stf/‘-, -ply P 0 "1"rtCY1
YF
gG -
L -
�,\I d11}rd f' 5Q rs-J-1q to
)J -
.r 3-Okla
.-- IttV
_101Q' r9 V-917r
sl-x- _
r4_3 *-N9Y 61 -viV - 6 ti-goi
fevv—
AV°q QOQM
/ • 4 1v
-- 1 , . i h ,3 f qQo rn
•e' -'11 ..,_,_... -i— IQ) --------0.- ,t )1
_J_o' m m -V-5 r
cfN i? f'li,_1 ,,\Ai tlx t
I
FANS $1, It. - Al-GIG SUPPLY FAN
I, i.NTE"PE=ED S_P°LY UNIT WITH 10' BLOWER IN SIZE is HOUSING
2. INTAKE HOOD WITH EZ FILTERS-LOW CFM
3. DOWN I:ISCHAR'E - AIR FLOW RICHT -> LEFT
*NOTE, SUPPLY DUCT MUST DE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH "',ST BE MAINTAINED
DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLI_ATION 201. DO NOT RELY ON UNIT TO SLP''ORT DUCT IN ANY WAY,
FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE E')GI°MENT.
SJG BESTED STRAIGHT DUCT SIZE IS 14' x 14'
BLOWER DISCHARGE
CURB
1 /4• \
1 � �
:j 1,,'
•► a I L___ ___J
3 7/8'
}
1: lin• — /
FLEX CONDUIT
FOR FIELD
WIRING
58'
2I 3/8'
32 1/B'
LIFTING LUG --f 111 • ® 1 . .
AIRFLOW
remSERVICEAIRFL❑W
DISCONNECT I® Immo
,-, a/4' 11337,-7' SWITCH
BLOWER/MOTOR
ACCESS DOOR
24' SERVICE
'° CLEARANCE 4E::,
3 3/4* '_—'
T 1
•
1 I I
:5 1/4' MINIMUM
STRAIGHT
1( DUCT
20' EQUIPMENT CURB PER AMCA■
L 21'
t .
ROOF OPENING 2' SMALLER THAN CURB DIMENSION.
1" YIN.
PITCHED CURBS ARE AVAILABLE O•
FOR PITCHED RO❑FS,
SPECIFY PITCH' 12'
EXAMPLEi 7/12 PITCH = 3C° SLOPE
12/8/2017 Fan Submittal
Page 1 of 2
Qrf1CQ
A Al ter.irr=__= Niru
conic ac!ur A1rCH'M1' :E 4!:i. ''YJ •
li
Order#3236744 Direct Order#3236744 Quantity:1 c
ern. «.......«
Fan # 1 DU5OHFA 82.57 lbs Construction Features
High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control Housing constructed of heavy gauge aluminum •Centrifugal backward inclined,
(speed control included for single phase only),disconnect switch and 13-3/4'. non-overloading wheel •Weatherproof safety disconnect switch •Grease spout
wheel. welded to housing •Vibration isolators •Continuous duty,thermal protected,
permanently lubricated,direct drive motor •Forces fresh air through motor to
Motor ensure long motor life •Variable Speed Control on Single Phase Units Only.
Model CK46HF21 HFOt-60-115•0.5 HP•1 Phs•115 V•8.4 FLA•60 Hz• (VFDs required to adjust speed for 3 phase versions) •Corrosion resistant
fasteners •Thermal overload protection •High heat operation(400°F) •Rated
ODP(Open Drip Proof) for restaurant and general ventilation applications •Grease classification tested
Performance
Volume:1000 cfm
SP:0.5"w.g.
BHP:0.181
RPM: 1168
Tip Speed:4204 fUmin
Altitude.0'
Installation Information
Unit Voltage:1 phs 115 V
Motor/Control Circuit:10.5 Amps MCA,15 Amps MOP,115 V,14 AWG Wire
Min.
FEATURESI
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS)
28 7/9 - ROOF MOUNTED FANS
R - RESTAURANT MODEL
MIE - UL 705 AND UL762
- VARIABLE SPEED CONTROL
- INTERNAL WIRING
- WEATHERPROOF DISCONNECT
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)
- HIGH HEAT OPERATION 300°F (149•C)
111110.
- GREASE CLASSIFICATION TESTING
c
27 1/4 NORMAL TEMFRAT 1R TCT
ii.ir 21 1/2 LEST FAN MUSTOPERATE CONTINUOUSLY
WHILE EXHAUSTINGING 'F AIR AT 300 (149°C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
iP-iI
DETERIORATING EFFECTS TO THE FAN WHICH
GREASE DRAIN WOULD CAUSE UNSAFE OPERATION.
ABNORMAI Fl ARE-UP TEST
t 2 EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
{ 13 1/4 + AT 600°F <316'C) FOR A PERIOD OF
+ 15 MINUTES WITHOUT THE FAN BECOMING
— DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
17 L/2 •
' \K\ `,1 -
DUCTWORK BETWEEN
EXHAUST RISER ON HOOD
AND FAN (BY OTHERS)
The manufacturer reserves the right to use alternate components from alternate vendors that meet the operating requirements of the product but may have slightly different specifications.
This includes motors,pulleys.belts,bearings,blower wheels.electrical parts.etc The manufacturer reserves the right to alter any dimensional characteristics of the product as a result of
continuous improvements. It is the purchaser's responsibility to employ qualified personnel to install and"start-up"the equipment.
https://www.captiveaire.com/Catalog/FanSubmittal.asp?nJobfansid=480696&nFanunitid=1614&nManflablid=1&nPageno=1 1/2
Electrical Controls
Installation, Operation, and Maintenance Manual
CA
RECEIVING AND INSPECTION
Upon receiving unit, check for any interior and exterior damage, and if .found, report it
immediately to the carrier. Also check that all accessory items are accounted for and are
damage free.
WARNING"
Installation of this control panel should only be performed by a qualified professional who has
read andunderstands these instructions and is familiar with proper safety precautions.
Improper installation poses serious risk of injury due to electric shock and other potential
hazards.Read this manual thoroughly before installing or servicing this equipment. ALWAYS
disconnect power prior to working on module.
Save these instructions. This document is the property of the owner of this equipment and is
required for future maintenance. Leave this document with the owner when installation or
service is complete.
•
A0023032
August 2014 Rev.7
Component Description
Temperature Sensor
The temperature sensor is a 10K Ohm Thermistor. The " _' ;_
sensor gives constant feedback to the controller. One ' ;• . .ri
sensor is installed in every riser. •
•
Room Temperature Sensor
The Room temperature sensor is a 10K Ohm Thermistor. The sensor provides constant r.
room temperature to the controller. It should be installed on a wall somewhere in the ,J
space but not directly under the hood or close to an appliance so that the reading is not
affected by heat.
Typically a system will have one room temperature sensor. However systems
configured with 2 fan zones have the option to be ordered with 2 room temperature
sensors, one for each zone. They should be mounted in the space accordingly.
HMI
The HMI is designed to withhold grease and water when installed on
the face of the hood or utility cabinet. - .. .
The HMI is connected to the ECPM03 through a CAT-5 cable. If the --r I
HMI is installed on the face of the hood, a high temperature CAT-5
Cable is used. t._ _ _ i
The HMI can be mounted to a standard 2-gang junction box.
Current Sensor
One or several current sensors are included in the panel when the ;,J-t,-
Proving Option has been ordered. A current sensor has a solid core and �' d' `a
provides a 4-20 mA analog output that is proportional to the current
measured. It has an adjustable range of 0-10 amp, 0-20 amp or 0-50 '.-- •
ampbased on theposition of the jumper on the topof it: L, M or H ,.-��M °0�
1 P ""
respectively. The juniper is typically adjusted at the factory. The range ..--. . �Thz,'=
selected should be the smallest range possible that includes the FLA of
the motor being monitored. --
' r:
racy[
bJJiL
23 A0023032
August 2014 Rev. 7
• v..,:,-,,,,,,,,T S.. r ni,st-3 ,c, .o yr r
S s -•w..glif *rw a+a�7
-,,C+< w `\ ,Icy# 4,, t ,, ,,,..
4
3MTM Fire Barrier Duct Wrap 615+ .;� FIRE BARRIER FLEXIBLE WRAP
Proauct Data Q°# P § 18 AIR
Z= .DUCT
Fire Protect on Fre Protection
In1 . Product Description 3M"Fire Barrier Duct Wrap 615+is a flexible fire-resistant wrap CC
consisting of an inorganic fiber blanket encapsulated with a scrim-reinforced foil.The product is 1-1/2 in.thick, 1� NFPA'
6pcf density.'It is used to fire rate commercial kitchen grease ducts as well as ventilation ducts.3M"Fire Bar- 96
ICC-ES ESR-1255
rier Duct Wrap 615+is a proven alternative to 1-or 2-hour fire-resistant rated shaft enclosures for grease ducts
(ICC-ES ESR-1255).With its excellent insulating capabilities,low weight and thin profile,it is an ideal choice
LISTED
for a duct enclosure system.This non-asbestos'wrap installs easily due to its high flexibility and strength. SGA Pow USTED
'1n accordance with the tolerances in ASTM C 892 Standard Specification for High-Temperature Fiber Blanket Thermal Insulation. 4.)1,0.
7 Has been demonstrated to be soluble in the lungs according to EU guideline 97/69/EG,for biopersistence.
1•ok ., s C US
1.115
11.
- Product Features Intertek Intertek
• Two-layer wrap for grease ducts • High flexibility for installation ease FIRE RESISTANT DUCT FIRE RESISTANT DUCT
>+ rated as a shaft alternative per • Foil encapsulated for blanket SEE INTERTEK DIRECTORY SEE INTERTEK DIRECTORY
ASTM E 2336 protection,less dust,and high
• Zero clearance to combustible wrap strengthc.,"". Fjv0
`•4: •- throughout the entire enclosure Widest range of penetration U
r.r system for congested spaces seal systems
• Butted inner layer in 2-layer • Available in 24 in.x 25 ft.(609.6
Grease Duct A Applicationsp BATTS AND BLANKETS
flexible and lightweight with a thin pp mm x 7.62 m)and 48 m.x 25 ft. FOR USE IN FIRE RESISTIVE DUCT ASSEMBLIES
• One-layer wrap for fire-resistive (1219.2 mm x 7.62 m)rolls SEE UL FIRE RESISTANCE DIRECTORY
profile for easier application and ventilation ductsper ISO 6944 9009
reduced space requirements Blanket adhered to foil scrim
2. Applications 3M'Fire Barrier Duct Wrap 615+is an ideal fire resistive enclosure for com-
mercial kitchen grease ducts and ventilation air ducts.It is a proven performance alternative to a 1-or 2-hour '-U•'
fire-resistant rated shaft enclosures for grease ducts and provides zero clearance to combustible construction Rv`
throughout the entire enclosure system.3M"Fire Barrier Water Tight Sealant 1000 NS,3M"Fire Barrier Water
Tight Sealant 1003 SL or 3M'"Fire Barrier Silicone Sealant 2000+is used in combination with 3M"Fire Barrier CSFM
Duct Wrap 615+to firestop the duct when the duct penetrates fire-rated floor or wall assemblies.3M"Fire Bar- LISTING No.
rier Duct Wrap 615+also provides a firestop solution where a T rating is required for penetrations located outside
wall cavities or outside fire-resistance rated shaft enclosures. 2440-0941:112
Two-layer grease duct applications:3M"Fire Barrier Duct Wrap 615+meets the criteria of ASTM E 2336 Standard Test
Methods for Fire Resistive Grease Duct Enclosure Systems.
Single-layer air duct applications:3M"Fire Barrier Duct Wrap 615+has passed ISO 6944-1985 Fire Resistance Tests—Ventilation Ducts.
T rating for metallic through-penetrating items:3MTM Fire Barrier Duct Wrap 615+is used in conjunction with 3M Fire Barrier sealants to
achieve up to 2-hour equal F&T ratings in ASTM E 814(Ul 1479)tested through-penetrations.
3. Specifications Installation shall be in strict accordance Typically Specified Division or Section
with manufacture's written instructions, as shown on the a roved shopDrnslon 7—Thermal and Moisture Protection
pp Section 23 07 13 Duct Insulation
drawings. 3M" Fire Barrier Duct Wrap 615+ shall be a high-temperature Related Sections
fiber blanket thermal insulation encapsulated in a fiberglass-reinforced alu- Section 07 2100—Thermal Protection
minized polyester foil. Duct Wrap density shall be nominal 6 pcf(96 kg/m3) Section 07 21 16—Blanket Insulation
and have a nominal 1-1/2 in. (38.1 mm)thickness. The fiber blanket shall Section 23 84 00—Firestopping
Section 2300 00 Heating,— Ventilation and Air-Conditioning(HVAC)
have a continuous use limit of 1000°C(1832°F). The blanket thermal resis- Section 23 31 13—Metal Ducts
tance(R-value)at ambient temperature shall be minimum 6.3 °F ftp hr .
Btu
Smoke Developed Index and Flame Spread Index of the bare blanket, and
of the foil encapsulated blanket shall be 0/0. The foil encapsulation shall be 3111I
bonded to the core blanket material.
i'or trcnnical;uptort rotating 7')3M Fne Prwtec'ioti proUucts and Systems.call: 1-3(r:-328-I(507
=tir Irore information on 3f -ire Prcat:ction?t.:ducts,visr:www.3m.com/`irestou
Typical Hinge Kit
RATE PARTS INCLUDED
HINGE KIT INSTALLATION FAN BASE / .Y(LCR) ""`7.7.1',;m
2-FAN PLATES(LEFT t PICNNT)
CUA '/. 2- CLFB HATE_ (LEFT L RIGHT)
CLOSED POSILON PLATE 2-WHI2 BOLTS
(LEFT) `y�� 6 -WHIZ NUTS
„'/'-''. \ GAN r y/ SFEET METAL:CREWS
/1 12-SHORT 41/2-LG.)
`\�� / ` 12-LING.3/4-LG.>
� 4a DETAIL •A' HINGE MT FIELD INSTALLATION
,1 DETAIL'A' . '•I a .
V f
STEP I)
I �I • ASSEMBLE FAN PLATE WITH CURB PLATE AG SHOWN ON PIC I
/ Alm PIC.2 or PARTS ARE NOT ASSCHBLEL).
/ AIM - _ _ PIC. 1 vM[:
IL . PIG. r NUT
`� • ,,
Nli , •�, lOLi
•
A NA
FAN CURB
PLATE CURB PLATE FAN
`-(SIB WIGHT) RATE <LEFT)
PLATE
GREASE `m, (RIGHT) (LETT)
PIPE
(OPTIONAL, STEP 2)
SCC DETAIL'A' FOR POSITIONING FAN PLATE ON FAN BASE
GREASE OPEN POSITION LINE LP FAN BASE EDGE TTI INSIDE EDGE OF FAH PLATE
DO AS SHOWN ON PIE 3
LORIONAL) -.
PIC. 3
(`}p��1 ATTENTION! A FAN BASE I
_� `!�`\ INSTALLER M.AT FAN BASE EDGE
\. READ LABEL NEAR '\
DISCONNECT GVTTCHI
MESSAGE ON LABEL. _
'IHSTPLLER SHOULD I•, (\ r
�,� SUPPLY ENCWH '• \ ../ INSIDE EDGE OF FAN PLATE
1
\ �-i 1 ELECTRICAL CORD \ STEP 3j
FAN BASE TO LET FAN \
MAKE CRVLETE SCREW THE FAN PLATE TO THE FAN BASE USING THE
SWING' (12) DIRT 1/2'LG.SHEET METAL SCREWS.
\
`
•
NOTE.IF TME SCREWS HIT THE CURB, THEN RUN n1E SCREWS
\\\UBEL�/ \ FRC(IN:ICE THE FAN BASE,ALWAYS BE SURE THAT SCREWS
/ �/
, DD NOT INTERFERE WITH CURB AIN WREN F +PINGS SEE PIC.1.
/f
RUN PIC. 4 RUN
CREW
r'
SFROM FAN BASE rFRCN
-41
NMIINSIDE OUTSI DC
•
I—2 APPROLCLRB
APPROX. tet.
STEP 4)
SCREW THE CURB PLATE TO THE CURB USING THE
412)LONG 314'LG.SHEET METAL SCREWS.
/ TIGHTEN NUT AND BOLT ASSEMBLY.ENSURE FAN SWINGS
PROPERLY.
Typical Grease Box Installation
•
GREASE BOX INSTALLATION PARTS INCLUDED .c....1,-,.:
GREASE BOX
CLOSED POSITION GREASE MON COVER
GREASE PIPE GREASE BOX FIELD INSTALLATION
FANAMIIMINII
SHEET METAL SCREWS
_��� 3-LONG(3/4' LQ) STEP 11
ATTACH GREASE BOX COVED TO TINE CURB,
_-- � Z • � ICU 3'DIMENSION AS SHOWN ON PIC,L '
AIDI
SCREW GREASE BOX COVER TO CURB USING(3)U3NG(314' LG.X
GRE ® O . IJ 0 SCREWS AS SHOWN ON PIC.2
BEx 1:.'/ HINGE • I.
mil CURB
COVER � I _KIT
(OPTIONAL) _ _F.. . PIC. 2
` In
/ C7E)- `LRB
GREASE .4
BOX
BOX GREASE
EASE
COVER �L
......
-CUR) STEP 2) COVER
CREASE `1 ATTACH GREASE BOX TO GREASE BOX COVER,SLIDE AHD DROP.
PIPE
AS SHOWN ON PIC. 3.
GREASE
OPEN POSITION I CURB
GREASE
BOX PIG.
-� �
Tv
cx
g....,v N. GREASE BOX JO
- )4
\\:"..... .,i's,,
‘,
3 APP BOX •
5 1:16 STEP 31 PIC. 4
I)VB 7,1.: INSTALL CREASE PIPE AS SHOWN ON PIG 4. ......
- GREASE PIPE `•'
3 3/4 ��/ rap
-F
Alir9
BSSM 48-4 ETL PROFILE PFLEPEWDETM
�� �'�"�
STAINLESS STEEL EXHAUST HOOD WITH MAKEUP AIR VENT �` 0...,
� 2118 •
ETL APPROVED. N.S.F.LISTED.CONFORMS TO NEPA 96 � / ""---1°---"
ETL LISTED#3148390 CONFORMS TO UL STD 710 NFPA. ss
I ter--1
: --10.5Tp- �_10-
IJ i 4.
7
PROFILE VIEW-TYPICAL HOOD SYSTEM INSTALLATIONI IL
LOOLAI L FAN 3~� f 1� 25' "1'3°'MAKEUP N[NW
8451-{
5 +
44D 1 10'MIN I- I
ti/ .,__��___
63.
��I O CD
24.
NINGE KI1 !/ 'fs25'y I • (�'�
4F 1 Q CD
UNI 1 LOR nnx ExnAPei CURB rt
MIN 20.TALL r,A 12"TA
/ .
t/ 0
7 12"TALL
ROOF Thx.
u vadziaza
GALVANIZED .3...
t..............
l r.h�"Ahl MAKE.NP AIR �` X
���kGMIGE&K IRfN GRIM �" U Q
ALEN/READ r IDFr,D I.n.ED OVIri No, GREASE pl ICT L FY
/�'�--, LIQUID nGMi WELDED
51
`' LLI
,V BSSMIBJ O
j1 _ J n !10. PIAN VIEW DETAIL • filIZI1
.8• CC n
j 1 -' � �-10.5'+
•
to
REFORM.Fr riANDOFF :
•
OPTIONAL21-
/ Ns
NEE AL EXHAUST 10.5- lq. O
,,,,,
rFAL,F .i c.,IOW �F� COLLAR r'••••
11114 •,:S _1
,,,,,,;,/,
_l,_-- INCANDESCENT (N1 LU
} LIGHT FIXTURE w 48' 51•
1_ INSTALL IN ACCORDANCE \-____--"" + (111/14,1
F—
) WITH NEPA 96°AS WELL AS
ALL STATE&LOCAL CODES t
t
X
jv
1� II'
ON 1.110JR FIRM..j114111
`r„ / 1
OPTIONAL
SUPPLY COLLAR/ "*--18'—►
/ FIRE DAMPER
1
j HOOD INFORMATION(PER HOOD)
I
HOOD FILTERS LIGHTS
TYP.COOKING EQUIPMENT MODEL LENGTH WIDTH HEIGHT CONSTRUCTION
TYPE QTY HEIGHT LENGTH QTY TYPE
TYPE:430 ALUMINUM
BSSM48-4-ETL 4' 48" 24" STAINLESS STEEL BAFFLE 1 20_ INCANDESCENT
GAUGE:113 wMANDLES 1 LIGHT FIXTURE
POLISH:t3 UL APPROVED 1 16" 25" UL APPROVED
CFM REQUIREMENTS(PER HOOD) OPTIONAL COLLARS(PER HOOD)
IF 1111
/�/ EXHAUST SUPPLY EXHAUST SUPPLY STANDOFF NOM WEIGHT ACCESSORIES
/-/::,
���� i� 1.120 G.755.P. S960.i25.P. OTT SIZE CM SIZE ❑ NONE 200 L65
® 3"
1 10.5"X10.5" 1 16"X 10" 0
(.�s\I1�1 3- - -'oo-31 Vo s- )o-svi
LS4.YL gI 1 crat/31tia--n-d ,�i' '-sNm t1 q(3°)ea
.\ _
X20
7
Cl,
Vo N.rt-gj)iq N-3j —
/,-- I9/
N- ,A V-t7?
m ?ftil 6111>tviv _ WNW,.3vi.
I
A'
- ' LI 1110 5112 .g40rn
ri
ne- --4 --i- _ I QIYe
41 • ..4 u n
yonct S3 a-0 m V-5 4)r
l?orD ii V11,_1 a-9viti[15(1
1
12/8/2017 Fan Submittal
Page 1 of 2
Gu
A a a�� srirar/�
!
coaeeaclac a;rr,H -, .h, r, M!b
Order#3236744 Direct Order#3236744 Quantity:1 au. \
Fan# 1 DU50HFA 82.57 lbs Construction Features
High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control Housing constructed of heavy gauge aluminum •Centrifugal backward inclined,
(speed control included for single phase only),disconnect switch and 13-3/4" non-overloading wheel •Weatherproof safety disconnect switch •Grease spout
wheel. welded to housing •Vibration isolators •Continuous duty,thermal protected,
permanently lubricated,direct drive motor •Forces fresh air through motor to
Motor ensure long motor life •Variable Speed Control on Single Phase Units Only.
Model CK48HF21 HFOt-60-115•0.5 HP•1 Phs•115 V•8.4 FLA•60 Hz• (VFDs required to adjust speed for 3 phase versions) •Corrosion resistant
ODP(Open Drip Proof) • fasteners •Thermal overload protection •High heat operation(400°F) •Rated
for restaurant and general ventilation applications •Grease classification tested
Performance
Volume:1000 cfm
SP:0.5"w.g.
BHP:0.181
RPM:1168
Tip Speed:4204 ft/min
Altitude:0'
Installation Information
Unit Voltage:1 phs 115 V
Motor/Control Circuit:10.5 Amps MCA,15 Amps MOP,115 V,14 AWG Wire
Min,
FEATURES;
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS)
28 7/8 - ROOF MOUNTED FANS
- RESTAURANT MODEL
111111111111111 - lL705 AND UL762
- VARIABLE SPEED CONTROL
- INTERNAL WIRING
- WEATHERPROOF DISCONNECT
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)
- HIGH HEAT OPERATION 300•F (149°C)
O O - GREASE CLASSIFICATION TESTING
a c
27 1/4 �Ir�ti NORMAL TEMPERATURE TEST •
EXHAUST FAN MUST OPERATE CONTINUOUSLY
21 1/2
WHILETIPG TIR AT (1E9•C)
UNTIL ALLLL FAN N PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
GREASE DRAIN WOULD CAUSE UNSAFE OPERATION.
i'-I'— ADNDRMA' El ARE-IJP TEST
2 EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
+ y 13 1/4 + AT 600°F (316°C) FOR A PERIOD OF
1 15 MINUTES WITHOUT THE FAN DECOMING
— DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
..I 17 1/2
DUCTWORK BETWEEN
EXHAUST RISER ON H00D
AND FAN (BY OTHERS)
The manufacturer reserves the right to use alternate components from alternate vendors that meet the operating requirements of the product but may have slightly different specifications.
This includes motors,pulleys,bets,bearings,blower wheels,electrical parts,etc...The manufacturer reserves the right to alter any dimensional characteristics of the product as a result of
continuous improvements. It is the purchaser's responsibility to employ qualified personnel to install and"start-up"the equipment.
https.//www.captiveaire.com/Catalog/FanSubmittal.asp?nJobfansid=480696&nFanunitid=1614&nManflablid=1&nPageno=1 1/2
FANS *1, #? - Al-GID SUPPLY FAN
1. ,.VTEMPE=ED SL.PPLY UNIT WITH 10' BLOWER IN SIZE 1t: HOUSING
2. INTAKE HOOD WITH EZ FILTERS-LOW CFM
3, DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT
*NOTE SUPPLY IJ_T MUST BE INSTALLED TO MEET SMAGNA STANDARDS, A MINIMUM STRAIGHT D_01. LENGTH MUST BE MAINTAINED
DOWNSTREAM OF J\IT DISCHARGE AS OUTLINED IN ARCA PUBLICATION 201. DO NOT RELY 0'. .:IT TO SUP'ORT DUCT IN ANY WAY.
FAIL.:RE TO ^RO,E?LY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORY•A''E OF THE E)UIPMENT.
SLII-;11ESTED STRAICHT DUCT SIZE IS 14' x 1d'
BLOWER DISCHARGE-
CURB
0 1
3 7/8' `
J
-- 1. 1/..' -
FLEX CONDUIT
FOR FIELD
WIRING
58' -
27 3/8' -
32 :i B'
LIFTING LUG s • - e .
AIRFLOW
+ SERVICEAIRFLOW
DISCONNECT-�'® ♦m..
P2 2/4' IiIg ° SWITCH
BLOWER/MOTOR
ACCESS DOOR
0 24' SERVICE
1 CLEARANCE RE::.
3 .i/4' 1
i 1
:, 1/4'
MI\I'NM
STRAI,,NT
i A
20' EQUIPMENT CURB - PER M%4�
ti
:111 21'
ROOF OPENING 2' SMALLER THAN CURB DIMENSION.
1 "I\. :4'
PITCHED CURBS ARE AVAILABLE /3'
FOR PITCHED ROOFS.
SPECIFY PITCH: 12'
EXAMPLE: 7/12 PITCH = 30' SLOPE
Electrical Controls
Installation, Operation, and Maintenance Manual
17
•
•
RECEIVING AND INSPECTION
Upon receiving unit, check for any interior and exterior damage, and if found, report it
immediately to the carrier. Also check that all accessory items are accounted for and are
damage free.
WARNING!!
Installation of this control panel should only be performed by a qualified professional who has
read andunderstands these instructions and is familiar with proper safety precautions.
Improper installation poses serious risk of injury due to electric shock and other potential
hazards. Read this manual thoroughly before installing or servicing this equipment. ALWAYS
disconnect power prior to working on module.
Save these instructions. This document is the property of the owner of this equipment and is
required for future maintenance. Leave this document with the owner when installation or
service is complete.
•
A0023032
August 2014 Rev.7
Component Description
Temperature Sensor
The temperature sensor is a 10K Ohm Thermistor. The
sensor gives constant feedback to the controller. One . •
_
sensor is installed in every riser. "`Y<=c' :�::' '
r:
••
Room Temperature Sensor
The Room temperature sensor is a 10K Ohm Thermistor. The sensor provides constant
room temperature to the controller. It should be installed on a wall somewhere in the
space but not directly under the hood or close to an appliance so that the reading is not
affected by heat. •
Typically a system will have one room temperature sensor. However systems
configured with 2 fan zones have the option to be ordered with 2 room temperature ,
sensors, one for each zone. They should be mounted in the space accordingly.
HMI -.
The HMI is designed to withhold grease and water when installed on
the face of the hood or utility cabinet.
The HMI is connected to the ECPM03 through a CAT-5 cable. If the E, I
HMI is installed on the face of the hood, a high temperature CAT-5
Cable is used. _�_...- i
The HMI can be mounted to a standard 2-gang junction box. • -
Current Sensor •
C`rtL `a w• Y-i
J dX"�y �•
One or several current sensors are included in the panel when the �:._�:-,�
Proving Option has been ordered. A current sensor has a solid core and =" 17
provides a 4-20 mA analog output that is proportional to the current
measured. It has an adjustable range of 0-10 amp, 0-20 amp or 0-50
amp based on the position of the jumper on the top of it: L, M or H .•;� �,T`7`�.
respectively. The jumper is typically adjusted at the factory. The range .,.. M . . �=
selected should be the smallest range possible that includes the FLA of
the motor being monitored.
- r:
ran k
+ u= uuaa
{,aus
W tier+w��,q
23 A0023032
August 2014 Rev. 7
''''-'7;.:' ,'-':17.7";',..1''S,''''.'''''-' .-'1'-':-' '',i-'-'''-:.-''' :- ''''''----:‘:-''::-.''.. :.:': ':''':'';' ':::"'"'. '''':?-'e
� t �A�'AMYRR4 fAY'�'�
..7k..- „4 ,•'' tarn...- -4"'1 ,,,,,,:;i...: ::-,•.):. -
''e t x +fls• r ''•'
44
t1
$
3MTM Fire Barrier Duct Wrap 615+ , ,
‘,' FIRE BARRIER FLEXIBLE WRAP
;r_ \ ¢ &NR
,,DUCT
ICC
Fire Protection Fre Protection1 . Product Description 3M" Fire Barrier Duct Wrap 615+is a flexible fire-resistant wrap IVV Fo
"-� 7
consisting of an inorganic fiber blanket encapsulated with a scrim-reinforced foil.The product is 1-1/2 in.thick, NFPA•
6pcf density.'It is used to fire rate commercial kitchen grease ducts as well as ventilation ducts.3M'Fire Bar- 96
cc-ES ESR-1255
rier Duct Wrap 615+is a proven alternative to 1-or 2-hour fire-resistant rated shaft enclosures for grease ducts
(ICC-ES ESR-1255).With its excellent insulating capabilities,low weight and thin profile,it is an ideal choice
LISTED
for a duct enclosure system.This non-asbestos'wrap installs easily due to its high flexibility and strength. t.Gn°a� ATE°
'In accordance with the tolerances in ASTM C 892 Standard Specification for High-Temperature Fiber Blanket Thermal Insulation. i
B Has been demonstrated to be soluble in the lungs according to EU guideline 97/69/EG,for biopersistence.
-..°R AT
c us
` :yli.
Product Features Intertek Intertek
• Two-layer wrap for grease ducts • High flexibility for installation ease RRE RESNT D UCT FIRE RESISTANT D CT
.t.4 a•- A rated as a shaft alternative per • Foil encapsulated for blanket SERERIE DIRECTORY SEE INTERTEK DIRECTORY
` ASTM E 2336 protection,less dust,and high
x 3`1-br' • • Zero clearance to combustible wrap strength N,�psstFi0'
throughout the entire enclosure Widest range of penetration ',
„ ,,;,. •„ ti,. �,,,_ system for congested spaces seal systems U
• Butted inner layer in 2-layer • Available in 24 in.x 25 ft.(609.6
Grease Duct A Applicationsft BAITS AND BLANKETS
pp mm x 7.62 m)and 48 m.x 25 ft. FOR USE IN FIRE RESISTIVE DUCT ASSEMBLIES
Flexible and lightweight with a thin • One-layer wrap for fire-resistive (1219.2 mm x 7.62 m)rolls SEE UL FIRE RESISTANCE DIRECTORY
profile for easier application and ventilation ductsper ISO 6944 90G9
reduced space requirements Blanket adhered to foil scrim
2. Applications 3M'Fire Barrier Duct Wrap 615+is an ideal fire resistive enclosure for com .0:
-
mercial kitchen grease ducts and ventilation air ducts.It is a proven performance alternative to a 1-or 2-hour
fire-resistant rated shaft enclosures for grease ducts and provides zero clearance to combustible construction ftp;,,
throughout the entire enclosure system.3M'”Fire Barrier Water Tight Sealant 1000 NS,3M"Fire Barrier Water
Tight Sealant 1003 SL or 3M"Fire Barrier Silicone Sealant 2000+is used in combination with 3M"Fire Barrier CSFM
Duct Wrap 615+to firestop the duct when the duct penetrates fire-rated floor or wall assemblies.3M".Fire Bar- LISTING No.
rier Duct Wrap 615+also provides a firestop solution where a T rating is required for penetrations located outside
wall cavities or outside fire-resistance rated shaft enclosures. 2440-0941:112
Two-layer grease duct applications:3M"Fire Barrier Duct Wrap 615+meets the criteria of ASTM E 2336 Standard Test
Methods for Fire Resistive Grease Duct Enclosure Systems.
Single-layer air duct applications:3M"Fire Barrier Duct Wrap 615+has passed ISO 6944-1985 Fire Resistance Tests—Ventilation Ducts.
1-rating for metallic through-penetrating items:3MTM Fire Barrier Duct Wrap 615+is used in conjunction with 3M Fire Barrier sealants to
achieve up to 2-hour equal F&T-ratings in ASTM E 814(UI 1479)tested through-penetrations.
3. Specifications Installation shall be in strict accordance Typically Specified Division or Section
with manufacture's written instructions, as shown on the approved shop Division 7 Thermal and Moisture Protection
Section 23 7 13 Duct Insulation
drawings. 3M" Fire Barrier Duct Wrap 615+ shall be a high-temperature Related Sections
fiber blanket thermal insulation encapsulated in a fiberglass-reinforced alu- Section 07 2100—Thermal Protection
minized polyester foil. Duct Wrap density shall be nominal 6 pcf(96 kg/m') Sectionection 0707 21
84 16-Blanket Insulation
00-Firestopping
and have a nominal 1-1/2 in. (38.1 mm)thickness. The fiber blanket shall Section 23 00 00-Heating,Ventilation and Air-Conditioning(HVAC)
have a continuous use limit of 1000°C(1832°F). The blanket thermal resis- Section 23 31 13—Metal Ducts
tance(R-value)at ambient temperature shall be minimum 6.3 °F-ftp hr .
Btu
Smoke Developed Index and Flame Spread Index of the bare blanket, and
of the foil encapsulated blanket shall be 0/0. The foil encapsulation shall be
bonded to the core blanket material. t 2
• r utrhnicitl`Sltpiiort rialating'•)3M1 i=1re Prwter:'ion{rocucts mil Systems call: 1-;;...i -._ ',;r'
',r Iron;inri:r matII))on 3M!"ire PrCttiction?rooms,V1SI::';JI,w3m,C0f11/fiI'E' tou
Typical Hinge Kit
MINOR
HINGE KIT INSTALLATION FAN BASE ,,A Fal PARTS INCLUDED ms
Y PLATE
\(LEI) 2-FAN PLATES CLEFT N PITA T)
CURB i,{ 2-CURB PLATES(LEFT L RIGHT)
CLOSED POSITION PLATE /. 2-WHIZ BOLTS
(LEFT) 6-WHIZ NUTS
/i ))FAN
1 �• SFEET METAL SCREWS
• , I 12-SIURT(7/2'LG.?
C. ' // -- — ,'• 12-LOG(3/4'LEL)
` /'
vu RETAIL'A'IIIIIII ei`I Q
S DETAIL "A" HINGE KIT FIELD INSTALLATION
II STEP 1)
' ASSEMBLE FAN PLATE WITH CURB PLATE AS SHOWN EN PIC 1
/ 11) AND PIC.2(IF PARTS ARC 1101 AL-MARLED.
��" //. / IIS -
�� PIC, 1 PIC. 2 NNE
! WHIZ_. NUT
`� MIT MOLT
`► I
;�., FAN •.CURT
PLATE CURB PLATE FAN
�`�/ cm) (RIGHT/ PLATE curb PUTT,
CREASE (RIGHT/ (LEFT)
PIPE
STEP 2)
(O'TIONA)
SCC DETAIL•A•FCR POSITIONING FAN PLATE ON FAN BASE
ONEASE OPEN POSITION LINE W FAN BASE EDGE TO INSIDE EDGE OF FAN PLATE
BD' AS SHOWN ON PIC 3
(EFTIONAL) r---- -
\. IP C• 3
ATTFNTIONI FAN BASE
INSTALLER MUST CAN DACE EDGE
READ /ECNEAR
,;
\ NSCONECT SNITCH
MESSAGE ON LABEL C A,
1r
��� INSTALLER,1 1 •
r �,
ELECTRICAL
EN..C �� /:• INSIDE EDGE DF FAN PLATE
\ _ ELELCTTRICAL COO "� \ STEP 3)
FAN BASE \ • MAIC TCppLETE • ,V
SWING' \ SCREW THE FAN PLATE TO THE FAN BASE USING THE
\� (I2)%CRT 1/2'LG.SHEET METAL SCREWS.
``\, O ' NOTE.IF THE SCREWS FET THE CURB.T)EN RUN TIE SCREWS
L's, FRO(INSIDE THE FAN BASE,ALWAYS RE SURE THAT SCREWS
� —/ DO NOT IMERC WITH CURD VFEN FAH SWINGS SCE PIC.I.
: Ø/
EW PIC4 rrCREW
SCREWFAIT BASE "rROI
0)/A rim?'—N,,DNSOE7 1/4 I—2 APPROX [LRBAPPT�x' STEP 4)SCREW TFT,CRB PLATE TO THE CURB USING THE
42)LONG 3/4'LG.SHEET METAL SCREWS.
TIGHTEN NUT AND BOLT ASSEMBLY.ENSURE FMN SWINGS
PROPERLY.
Typical Grease Box Installation
GNGCmI
I.
GREASE BOX INSTALLATION PARTS INCLUDED ""' ""
R
GREASE DO(
CLOSED POSITION GREASE BOX COVER
GREASE PIPE GREASE BOX FIFLD INsuud noN
FAN SLEET METAL SCREWS
3..LONGLG 13/4' LG.) STEP 1)
'� ATTACH CREASE BOX COVER TO TIE CURD.
NOLO 3'DIMENSION AS DOWN ON PIC.L '
SERE/GREASE BOX COWER 1O CURD USING(3)LOIN C3/4'LEU
ill 0 • SCREWS AS SHOWN ON PlC.2.
Bim( 1;/ HINGE I� ORB
COVER KIT
(�TIO AL)
ill
ill
'`— j dI- Imo•!fes 31
Iiiii
ift
,�� r CREASE • 4
. 0. COWER ,.' GREASE
(�}� Bm
M —CVRB STEP 2) COVER
GREASE _AIIP ATTACH GREASE BOX TO GREASE BOX COVER.SLIDE AND DROP.
PIPE
AS SHOWN ON PIC 3.
GREASE OPEN POSITION �`_- CURB GREASE
BOB BOX
PIC. ,� /-CD ZEN
ER
0441;\\ GREASE BOX
V, N.'4111j..AA'A 1
4...‘ \
Q 3 APPBOX •
5 I/16 ', � STEP 3) 'PIC_ l
T ve
//I ..'IllMy •
INSTALL GREASE PIPE AS DWI.ON PIC 4.
`' GREASE PIPE .N'
3 3/4 _/� ' (WNW
al
..ir
,,
9