Loading...
763 Atlantic Blvd COMM20-0012 13 of 26 E2-ELECTRICAL LIGHTINGHC HC 30 CONSULTCONSULTCONSULTMANAGERMEN'SWOMEN'SBREAKVAULTCLSUNISEXB.O.H.OPEN RETAILRETAILCOUNTERATMDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEHCHCLVOS/LV OS/LVDDDLVDOSOSLVLVOSLVOSLVOSLVOSOS/LVLVLVOSOSOSOSHNRHNREMERGENCY BALLAST DETAILSSWITCHED FIXTUREEMERGENCYBALLASTACBALLASTTEST SWITCHWALL SWITCHREDINDICATOR LIGHTUNSWITCHED FIXTUREEMERGENCYBALLASTACBALLASTTEST SWITCHREDINDICATOR LIGHTSVOLTAGELOWSENSOROCUPANCYIN LINE OR LOW VOLTAGE SWITCHLOADTYP ROOM WITH OCCUPANCY SENSORTYP.TYPICAL PANEL20A,2PNSPARETO LIGHTSTO BUILDING LIGHTSTYP.20A,1PNOTE:LIGHTING CONTROL DIAGRAM1/2" CONDUIT WITH #12 CONDUCTORTO OVERRIDE TIMER (1/2 - 2HOURS) AT ENTRY POINT. ADDFD34H TIMER.1/2" CONDUIT WITH PULL STRING TOALARM CONTROL PANEL WHEN AVAILABLE(2) ASTRONOMICAL TIME SWITCH TC-1 RESERVE POWER FEATURE NEMA 3R ENCLOSURE AND CLOCK MOTOR OF VOLTAGE COMPATIBLE WITH CONTROL CIRCUIT.CONTACTOR C-1 LOCATED IN NEMA 3R ENCLOSURE. SQ-D #SMG SERIES WITH CONTROL RELAYLIGHTING CONTROLLER EXTERIOR AND INTERRIOR N.O. 20A, VOLTS CONTACTS, VOLTS COIL . NEMA 1 ENCLOSURECONTROL DEVICE TO BE INSTALL THAT AUTOMATICALLY TURNS LIGHTING OFF WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE, EXCEPT SPACES WITH MULTISCENE CONTROL IN CLASS ROOMS, CONFERENCE ROOMS, ANDEMPLOYEE LUNCH/BREAK ROOMS.CCLIGHTING NOTES:1. ALL LIGHTING SHALL BE CONNECTED TO 120/208V 3Ø, 4W PANEL UNLESS NOTED OTHERWISE.2. REFER TO ARCHITECTS REFLECTED CEILING PLAN FOR EXACT LIGHTING FIXTURE HEIGHT AND LOCATION.3. ALL LIGHTING FIXTURES SHALL COMPLY WITH NEC 410.130(G).4. EACH SPACE ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL HAVE AT LEAST ONE CONTROL DEVICE TO INDEPENDENTLY CONTROL THE GENERAL LIGHTING WITHIN THE SPACE PER CHAPTER 4 FROM FBC ENERGY CONSERVATION.5. ALL EMERGENCY AND EXIT LIGHTING SHALL BE CONNECTED AHEAD OF LOCAL SWITCHING.6. ALL LIGHTS SHALL BE LED AND ALL LIGHTS SWITCHES GUARANTEED TO WORK WITH LED FIXTURES.7. GENERAL CONTRACTOR SHALL COMPLETE THE FUNCTIONAL TESTING OF THE LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATE, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THIS DOCUMENT AND MANUFACTURER'S INSTRUCTIONS PER FBCEC 6TH EDITION (2017) SECTION C408.3.18. CONTRACTOR SHALL PROVIDE DOCUMENTATION CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF FBCEC 6TH EDITION (2017) SECTION C405 AND THE DOCUMENTATION TO BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY PER FBCEC 6TH EDITION (2017) SECTION C408.3.2.LIGHTING SYMBOL LEGEND2' x 4' LIGHT FIXTURE.SQUARE COMPACT CEILING LIGHT FIXTURE.2' X 2' LIGHT FIXTURE WITH INTEGRAL EMERGENCY TYPE BALLAST. "NL" INDICATES FIXTURES IS ON A NIGHT LIGHT CIRCUIT (NOT SWITCH)ROUND COMPACT CEILING LIGHT/DOWN LIGHT.STRIP, OR INDUSTRIAL LIGHT FIXTURE.WALL MOUNTED FULL-CUTOFF FIXTURE.WALL MOUNTED COMPACT LIGHT FIXTURETRACK LIGHT. LAMPS AND LEGHT AS SHOW ON PLANS.2' x 4' LIGHT FIXTURE WITH INTEGRAL EMERGENGY TYPE BALLAST. "NL" INDICATES FIXTURES IS ON A NIGHT LIGHT CIRCUIT (NOT SWITCH)EMERGENCY OR NIGHTLIGHT (NL) COMPACT CEILING LIGHT/DOWN LIGHT.EXIT-EMERGENCY COMBO LIGHT. ARROWS INDICATE DIRECTION AND SHADE INDICATE FACE(S) OF FIXTURE. CEILING MOUNTED DUAL TECNOLOGY OCCYPANCY SENSOR.CEILING MOUNETD DAYLIGHT PHOTOCEL SENSOR.CEILING MOUNTED OCCUPANCY/VACANCY SENSOR AND DAYLIGHT PHOTOCELL COMBO.ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)SINGLE POLE SWITCH.OS= OCCUPANCY SENSOR3= THREE WAYD= DIMMINGT= TIMERLV= LOW VOLTAGE4= FOUR WAYEXIT LIGHT. ARROWS INDICATE DIRECTION AND SHADE INDICATE FACE(S) OF FIXTURE. EMERGENCY BATTERY OPERATED WALL PACK WITH TWO AIMABLE HEADSRECESSED 1' X 4' FIXTURE.OSDLSDLSOSDIGITAL MULTI-ZONE WALL KEYPAD LIGHTING CONTROL.NLNLNLABREVIATIONSNEUTRALCH COUNTER HEIGHTELECTRIC WATER COOLEREWCHIGH INTENSITY DISCHARGEH.I.D.COMPACT FLUORESCENT LAMPCFLAA/CACAFFAFGAHUAWGCCONCCONDCUDISCELECEMEMSEMTEFEXFAAMPERESAIR CONDITIONINGALTERNATING CURRENTABOVE FINISHED FLOORABOVE FINISHED GRADEAIR HANDLING UNITAMERICAN WIRE GAUGECONDUITCONCRETECONDUITCOPPERDISCONNECTELECTRICALEMERGENCYENERGY MANAGEMENT SYSTEMELECTRICAL METALLIC TUBINGEXHAUST FANEXISTINGFIRE ALARMGGFIGNDGRCHVACJKAICKVAKWLTGKCMILMCUMHNNANFNECNICNLNEMANFPAGROUNDGROUND FAULT INTERRUPTERGROUNDGALVANIZED RIGID CONDUITHEATING, VENTILATING ANDJUNCTION(THOUSAND) AMPEREKILOVOLT-AMPERESKILOWATTLIGHTINGTHOUSANDS OF CIRCULAR MILSMASTER CONTROL UNITMETAL HALIDENOT APPLICABLENON-FUSEDNATIONAL ELECTRICAL CODENOT IN CONTRACTNIGHT LIGHTNATIONAL ELECTRICALNATIONAL FIREO.C.PPNLPVCRMRGSSPECSSTYPUONVWWPON CENTERPOLEPANELBOARDPOLYVINYL CHLORIDEROOMRIGID GALVANIZED STEELSPECIFICATIONSTAINLESS STEELTYPICALUNLESS OTHERWISE NOTEDVOLTSWIREWEATHERPROOFFIRE ALARM CONTROL PANELFACPENCLOSED CIRCUIT BREAKERECBNIGHT LIGHTNLMOTOR CIRCUIT PROTECTIONMCPAIR CONDITIONINGINTERRUPTING CAPACITYMANUFACTURERS ASSOC.PROTECTION ASSOC.I.G.ISOLATED GROUNDTVSSTRANSIENT VOLTAGE SURGEFLORIDA POWER AND LIGHTFPLSUPPRESSION---------------------------------------------------------------ETR EXISTING TO REMAIN-LEDLIGHT EMITTING DIODE--TBDTO BE DETERMINED-WWATT-P3P3P3R2R2R4R3R3R1 R1 R1 R1P2 P2 P2 P2P2THTH THEBUEBUW1KeyPad-1abce1SW-aA-30SW-eSW-cSW-bSW-ddA-30A-30A-30DLSOS22A-32A-32A-3222A-32Via timeclock/ photocellREBUEBUEBUEBUA-32A-32A-30A-30A-30W1DLSOSDLSOSR3 R3R3 R3R3 R3R3R3R3EBUEBUA-30R3R3R3R32A-30R3R32A-30R3R32A-30R3R32A-30R3A-14A-14R3R3R32R2EBUA-322A-32R2R2R2R2 R2 R2R2 R2 R2R2 R2R2R2R2R2R2R3fSW-f22R3EXISTING METER CENTERW1A-20A-30A-32A-32A-32A-32RA-32EBUEBUEBUEBUEBUA-30A-3022A-30A-32A-32P2P2421213111551351101110111015315312155513112144135SWITCHING AND 0-10V DIMMING PACKMODEL #: nPP16 DEQUIPMENT LEGENDOCCPANCY/VACANCY SENSORMODEL #: nCM PDT 10OCCUPANCY/VACANCY SENSOR AND PHOTOCELL COMBOMODEL #: nCM PDT 10 ADCXDIMMER/OCCUPANCY/VACANCY WALL SWITCH COMBINATION UNITMODEL #: WSX DON/OFF RAISE/LOWER DIMMER OVERRIDE SWITCHMODEL #: Npodm DXOCCUPANCY SENSORMODEL #: nCM PDT 10ON/OFF RAISE/LOWE 2 ZONES DIMMER OVERRIDE SWITCHMODEL #: Npodm 2P DXDIMMER/VACANCY DIMMING PACKMODEL #: NPP16 D SAON/OFF RAISE/LOWER 4 ZONES DIMMER OVERRIDE SWITCHMODEL #: NPODM 4P DXDAYLIGHT HARVESTING PHOTOCELLMODEL #: nCM ADCX RJBPLUG LOAD CONTROL POWER PACKMODEL #: nPP20 PL20 AMP 120V SWITCH DUPLEX RECEPTACLE.PROVIDE LABEL ON THE COVER.CAT-5e SPLITTER12345678910111213REVISIONSPROJECT NUMBER:ARCHITECTURE, DESIGN & DRAWING SERVICES# AA 26001108BRIAN P. FREDLEY, ASSOC. AIA, PROJECT MANAGERDALLAS B. PEACOCK, AIA, ARCHITECT# AR 0009706207 FAIRVIEW AVENUE, DAYTONA BEACH, FL, 32114PH: (386) 257-0502 FX: (386) 257-1050E-MAIL: bpfdesign@cfl.rr.com WEBSITE: bpfdesign.netDATE:SHT NO.ARCHITECT'S / ENGINEER'S SEALSCALE: AS SHOWN#1325 S. Bumby Ave. Orlando, Florida 32806PH: (407) 896 7411 / FX: (407) 896 7412EMAIL: epgroup@att.netCA#8126MTF2003903/19/2020CURALEAF ATLANTIC BEACH - INTERIOR MODIFICATION MEDICAL MARIJUANA FACILITYE-2ELECTRICAL PLAN - LIGHTINGGENERAL CONTRACTOR: T.B.DPROJECT LOCATION: 763 ATLANTIC BEACH BOULEVARD, UNIT 1, ATLANTIC BEACH, FL 32233OWNER/DEVELOPER: CURTIS BARKMAN, DIRECTOR OF PROJECT MANAGEMENT, PALLIATECH, INC., 301 EDGEWATER PLACE, SUITE 405, WAKEFIELD, MA 01880 PH:(781)451-0160MOHSEN FARAJI, P.E. 43599LIGHTING FIXTURE SCHEDULEType Mark Description Manufacture Model Lamp Apparent LoadEBU EMERGENCY LIGHTS W/ BATTERY BACK-UP EATON AP2SQLED LED 2 VAP2 PENDANT LED LIGHT FIXTURE SPECTRUM DSP2INC MW CM36 GC CTC MW NONE LED 10 VAP3 PENDANT LED LIGHT FIXTURE BROWNLEE 2612 24 NT 225N BMB CC1 27K LED 50 VAR SELF POWERED COMBINATION EXIT-EMERGENCY LIGHT EATON APCH7R LED 10 VAR1 2X4 FLAT LED PANEL LITHONIA EPANL 24 40L 35K LED 40 VAR2 2X2 FLAT LED PANEL LITHONIA EPANL 22 34L 35K LED 32 VAR3 1X4 FLAT LED PANEL LITHONIA EPANL 14 40L 35K LED 39 VAR4 RECESSED LED LIGHT FIXTURE JUNO TC20 / 204 WWH LED 10 VATH TRACK LED LIGHT FIXTURE JUNO T691 WH / 11PAR30DIM/930/NF25 #58117 LED 15 VAW1 OUTSIDE WALL MOUNT, LED FIXTURE TBD BY OTHERS SPECIFIED BY OTHERS SPECIFIED BY OTHERS LED 66 VAREFERENCE NOTESNumber Description1 PROVIDE DIGITAL KEY PAD LIGHTING CONTROL FOR MULTIPLE SWITCHESCONNECTION.2 SEE LIGHTING CONTROL DETAILS FOR WIRING CONNECTION, AUTOMATIC CONTROLDEVICES PER FBC-EC 405.2.1.1/4" = 1'-0"E-2101-Electrical-Lighting