763 Atlantic Blvd COMM20-0012 15 of 26 E4-ELECTRICAL SPECIFICATIONSJ. LAMPS:PROVIDE NEW LAMPS IN ACCORDANCE WITH THE FOLLOWING:A) FLUORESCENT: 3500K/T8 OT T5/OCTRONB) INCANDESCENT: INSIDE FROSTED WITH A MINIMUM RATING OF 130 VOLTS UNLESS OTHERWISE INDICATED.C) LOW VOLTAGE MR-16 MEDIUM SPOTK. EXIT LIGHTS (SHOP DRAWINGS REQUIRED):PROVIDE EXIT LIGHT UNITS WHERE INDICATED ON DRAWINGS AND IN ACCORDANCE WITH ALL LOCAL CODEREQUIREMENT, INCLUDING FIRE DEPARTMENT.L. POWER AND CONTROL WIRING TO EQUIPMENT:1. PROVIDE ALL ELECTRICAL POWER CONNECTIONS TO EQUIPMENT INDICATED ON PLANS UNLESS OTHERWISEDIRECTED.A) PROVIDE ALL CONDUITS AND WIRING FROM PANEL TO MOTOR TERMINAL.B) PROVIDE ALL DISCONNECTS REQUIRED AND MAKE ALL POWER CONNECTIONS IN THESE CIRCUITS2. CONTROL EQUIPMENT, MOTOR STARTERS, RELAYS, LINE VOLTAGE CONTROLS TRANSFORMER, LOW VOLTAGECONTROLS AND DEVICES NECESSARY FOR THE OPERATION OF HEATING, AIR CONDITIONING, VENTILATION ANDPLUMBING SYSTEM FURNISHED AND SET IN PLACE BY RESPECTIVE SUBCONTRACTOR.3. ALL CONTROL WIRING UNDER DIVISION 15 OF SPECIFICATIONS.M. MOTOR STARTER1. ALL MOTORS SHALL BE FURNISHED AND INSTALLED BY MECHANICAL AND CONNECTED BY ELECTRICALCONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MOTORS STARTER NOT FURNISHED WITHEQUIPMENT.N. TELEPHONE SYSTEM:1. PROVIDE ALL RACEWAYS, PULL BOXES, OUTLETS AND TERMINAL BOARDS REQUIRED FOR SYSTEM SHOWN.A) TERMINATE RACEWAYS IN MANNER SUITABLE TO TELEPHONE COMPANY, IN LOCATIONS SHOWNB) COORDINATE ENTIRE SYSTEM WITH TELEPHONE COMPANY PRIOR TO INSTALLATIONC) GROUNDING AS INDICATED AND/OR DIRECTED BY LOCAL TELEPHONE COMPANYD) ALL TELEPHONE SYSTEM, INCLUDING EQUIPMENT, SWITCHES, AND WIRING TO BE PROVIDED BYOWNER/REPRESENTATIVE.GENERAL NOTES:1. CONCRETE WORK REQUIRED FOR THE INSTALLATION OR CONSTRUCTION OF ANY OF THE ELECTRICAL WORKSPECIFIED HEREIN SHALL CONFORM TO THE REQUIREMENTS OF THE APPLICABLE SECTIONS OF THESPECIFICATIONS.2. CONDUITS RUN EXPOSED AND VULNERABLE TO MECHANICAL INJURY SHALL BE RIGID, HEAVY-WALL, GALVANIZEDSTEEL OR ALUMINUM. ALUMINUM CONDUITS MAY NOT BE USED BELOW GRADE OR EMBEDDED IN CONCRETE.3. CONDUITS RUN EXPOSED OUTSIDE OR IN FLOOR SLABS SHALL BE RIGID, HEAVY-WALL, GALVANIZED ORSHERARDIZED STEEL OR SCHEDULE 80 PVC.4. CONDUITS RUN BELOW GRADE, EXTERIOR TO THE BUILDING SHALL BE SCHEDULE 40 HEAVY-WALL, HIGH IMPACTPOLYVINYL CHLORIDE ELECTRICAL CONDUIT.5. OUTLET BOXES AND COVERS SHALL BE GALVANIZED OR SHERARDIZED, ONE-PIECE PRESSED STEEL, KNOCKOUTTYPE, AND OF AN APPROVED MAKE.6. OUTLET BOXES SHALL BE EQUIPPED WITH PLASTER RING, EXTENSION RINGS OR FIXTURE STUDS AS MAY BEREQUIRED. DO NOT INSTALL BOXES BACK TO BACK.7. BOXES EXPOSED TO RAIN OR OTHER MOISTURE SHALL BE CROUSE-HINDS TYPE FS, FD CONDULET BOXES WITHAPPROPRIATE INUSE COVERS AND GASKETS.8. DUPLEX 20 AMP CONVENIENCE RECEPTACLES (COLOR AS SELECTED BY ARCHITECT,) 120 VOLT GROUNDING TYPE,SHALL HAVE TWO CURRENT-CARRYING CONTACTS AND ONE GROUNDING CONTACT WHICH IS INTENTIONALLYCONNECTED TO THE FRAME. (ONLY P&S OR HUBBELL #5242 OR LEVITON #5014 ARE APPROVED)9. GROUND FAULT RECEPTACLE SHALL BE DUPLEX TYPE.10. WEATHERPROOF DEVICES: ALL RECEPTACLES, SWITCHES AND JUNCTION BOXES ON THE EXTERIOR OF THE BUILDING, ON THE ROOF, OR INLANDSCAPED AREAS SHALL HAVE A WEATHERPROOF LIFT COVER PLATE.11. FURNISH & INSTALL CONDUCTORS OF THE SIZE AND TYPE SHOWN ON THIS DRAWING. ALL CONDUCTORS SHALLBE COPPER, TYPE THHN AND RATED AT 600 VOLTS. ALL SIZES ARE THE MINIMUM ACCEPTABLE TO SATISFYAMPACITY REQUIREMENT. CONSIDERATION SHALL BE GIVEN TO VOLTAGE DROP AND INSULATION SCCR WHERENECESSARY. 20A CIRCUITS GREATER THEN 75 FT IN LENGTH SHALL BE #10 AWG MINIMUM 20A CIRCUITS GREATERTHAN 130 FT IN LENGTH SHALL BE #8 AWG MINIMUM, CHANGE TO #12 AT J-BOX AHEAD OF FIRST RECEPTACLE.12. CONTRACTOR IS RESPONSIBLE TO IDENTIFY ALL UNDERGROUND UTILITIES PRIOR TO START OF EXCAVATION. THEENGINEER'S DRAWING SHALL ONLY BE USED AS A GUIDE, BASED ON EXISTING INFORMATION THAT WAS AVAILABLE.THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY LOCATION OF ALL CONDUITS.13. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE FIXTURE CATALOG NUMBERS TO ENSURE COMPLIANCE WITHTHE OTHER FACILITIES. IF THERE IS ANY DISCREPANCY, OR THE EXISTING MATERIAL IS NO LONGER AVAILABLE,THEN CONTRACTOR SHALL SPECIFY THAT IN HIS BID AND SUBMIT AN EQUIVALENT SUBSTITUTE FOR APPROVAL BYTHE OWNER.14. CONNECT ALL EMERGENCY LIGHTING (EXIT LIGHTS) ON THE SAME CIRCUIT AS THE NORMAL LIGHTING IN THE AREAAHEAD OF ANY SWITCHES AND/OR COMPLY WITH NEC 700-12.15. PROVIDE ALL EQUIPMENT, MATERIAL AND LABOR REQUIRED BY POWER COMPANY TO CONNECT THIS SERVICE TOTHE UTILITY POINT OF CONNECTION.16. PROVIDE #1/0 INSULATED COPPER GROUND WIRE FROM GROUND ROD TO BUILDING STEEL JOISTS (TYP. OF 2LOCATIONS) CONCEAL GROUND WIRE ON PERIMETER WALL. CLAMP GROUND WIRE TO STEEL JOIST WITHCOMPRESSION TYPE CONNECTORS AND CLAMPS. BOND GROUND WIRE TO SERVICE ENTRANCE GROUND LOOP.17. THE CONTRACTOR SHALL ASSUME UP TO 100' SETS OF SECONDARY CABLES AND CONDUITS TO BE INSTALLED TOTHE UTILITY POINT OF CONNECTION.18. USE OF "MC" STYLE CABLE SIZED #10 OR SMALLER IS PERMITTED IN BRANCH CIRCUITS WHERE PERMITTED BYLOCAL CODE.19. EXISTING RACEWAY AND CABLING MAY BE REUSED PROVIDED THAT THEY MEET NEC AND THE PROJECTSPECIFICATIONS.20.ALL PANELS SHALL BE U.L. LISTED AND OF THE SAME MANUFACTURER. PROVIDE SIZE AND TYPE AS INDICATED ONDRAWINGS. PANELS SHALL HAVE MINIMUM FULL SIZE NEUTRAL BUS AND 1/2 SIZE GROUND BUS.21.OPERATING AND MAINTENANCE MANUALS WILL BE PROVIDE TO OWNER BY ELECTRICAL CONTRACTOR AS REQUIRED PER SECTION C405.6.4 IN FBC-ENERGY CONSERVATION 6TH EDITION (2017).22. ALL EQUIPMENT INSTALLED SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) AND/OR LISTED AND LABELED AS AN ASSEMBLY BY AN NRTL PER NEC ARTICLE 90.7.PART 2 EXECUTIONA. GROUNDING1. PROVIDE EQUIPMENT GROUND SYSTEM IN ACCORDANCE WITH NATIONAL ELECTRIC CODE ARTICLE 250.A) ALL BRANCH CIRCUIT RACEWAY CONTAIN MINIMUM ONE NO. 12 AWG, TYPE TW, GREEN CODED GROUND WIRE.B) GROUND CONDUCTOR FOR PANEL FEEDER AND BRANCH CIRCUITS WITH OVER CURRENT PROTECTION RATEDMORE THEN 20 AMPERES SIZE.C) ALL FIXTURES, RECEPTACLES, SWITCHES BONDED TO GROUNDING SYSTEM.D) GREEN CODED GROUND CONTINUOUS FROM SERVICE ENTRANCE AND IN ADDITION TO NEUTRAL (1) NEUTRALNOT USED AS GROUND FOR EQUIPMENT. EQUIPMENT GROUND BONDED TO NEUTRAL AT MAIN SERVICEENTRANCE ONLY. (2) GREEN CODED GROUND CONDUCTORS TERMINATED UNDER EQUIPMENT GROUND BAROF PANELS.B. RACEWAYS:1. PROVIDE ALL RACEWAYS FOR ALL SYSTEMS. RACEWAY LOCATIONS SHOWN ARE DIAGRAMMATIC, UNLESSSPECIFICALLY NOTED, AND GOVERN OBSTRUCTIONS. EXPOSED RACEWAYS RUN IN NEAT MANNER ACCEPTABLETO ARCHITECT. RACEWAYS SUPPORTED USING CONDUIT CLAMPS SUPPORT OR HOLD RACEWAYS IN PLACE.A) RACEWAYS IMBEDDED IN EARTH, IN CONCRETE, IN DAMP OR WET LOCATIONS HOT DIPPED GALVANIZED RIGID,HEAVY WALL, THREADED NON-METALLIC, HIGH IMPACT DIRECT BURIAL TYPE II, PVC, WHERE PERMITTED BYCODES.B) RACEWAYS IN WALL OR FURRED CEILING TO BE ELECTRIC METALLIC TUBINGC) RIGID STEEL CONDUIT USED FOR EXPOSED EXTERIOR RACEWAYS.2. RACEWAYS REAMED SMOOTH AFTER CUTTING AND/OR THREADING.3. RIGID STEEL, THREADED CONDUITS AND SCHEDULE 40 PVC TO HAVE DOUBLE LOCKNUTS AND 0.Z. TYPE BBUSHING.4. ELECTRIC METALLIC TUBING COUPLING AND CONNECTORS MACHINED STEEL, SET SCREW TYPE.5. CONNECTIONS TO MOTORS AND VIBRATING EQUIPMENT MADE WITH SUFFICIENT FLEXIBLE CONDUIT SO VIBRATIONIS NOT TRANSMITTED TOA) USE FLEXIBLE, NON-METALLIC, LIQUID-TIGHT CONDUIT, UL APPROVED, FOR MOTOR CONNECTIONS.B) FLEXIBLE CONDUIT NOT USED FOR FIXTURE CONNECTIONS, EXCEPT RECESSED OR LAY-IN TYPE FIXTURES.C) MINIMUM SIZE 1/2-INCH.6. MINIMUM 24" RADIUS ELBOWS AND CONDUITS TO BE USED WHEN RISING FROM BELOW FLOOR ON SURFACE OFWALLS EXCEPT FOR LOW VOLTAGE RACEWAYS7. LOW VOLTAGE RACEWAYS (SYSTEMS OPERATING AT 70 VOLTS OR BELOW) TYPE 4 POLYVINYL CHLORIDE, ULFORMULA NON-METALLICA) LOW VOLTAGE RACEWAYS TO HAVE BUSHING AT ALL TERMINALS.B) NYLON PULL CORD, 5W POUND TEST MINIMUM, LEFT IN ALL RACEWAYS, IN WHICH CONDUCTORS ARE NOTINSTALLED.C. OUTLET BOXES:1. EXCEPT AS NOTED OTHERWISE, ALL OUTLETS LOCATED AS FOLLOWS: (MEASURED FROM FINISHED FLOOR LEVELTO BOTTOM OF BOX):A) SWITCHES---------------48" TO OPERABLE PARTB) RECEPTACLES------------15"C) WALL TELEPHONES--------48"2. PROVIDE REQUIRED OUTLETS, SWITCH, PULL AND JUNCTION BOXES OF SUITABLE TYPE FOR MOUNTINGINDICATED. BOXES SHALL BE GALVANIZED STEEL, NOT LESS THEN 4" SQUARE AND 1-1/2" DEEP UNLESSOTHERWISE INDICATED. BOXES SHALL BE SECURE TO STRUCTURE INDEPENDENT OF CONDUIT SUPPORTS.PLASTER RINGS SHALL BE PROVIDED FOR RECESSED UNITS.3. CONTRACTOR SHALL COORDINATE LOCATIONS OF UNITS INDICATED ON ELECTRICAL DRAWINGS WITH ACTUALLOCATIONS ESTABLISHED BY ARCHITECT OR MECHANICAL CONTRACTOR FOR CLARIFICATION BEFORE PRECEDINGWITH INSTALLATION.D. PANELBOARDS (SHOP DRAWINGS REQUIRED):1. BRANCH CIRCUIT PANEL BOARDS CIRCUIT BREAKER TYPE WITH BOLT-ON BREAKERS DEAD FRONT, LOCKINGDOOR, FLUSH LOCK MASTER KEYED.2. BREAKERS CLEARLY NUMBERED. WHERE SPACES ARE CALLED FOR, PROVIDE HARDWARE REQUIRED FOR FUTUREINSTALLATION OF BREAKERS. BUS AND HARD WARE BRACED FOR INTERRUPTING CAPACITY OF LARGESTBREAKER IN PANEL; INTERRUPTING RATING AS SHOWN ON DRAWINGS.3. PROVIDE TYPE CIRCUIT DIRECTORY UNDER TRANSPARENT SHIELD, ON INSIDE OF COVER OF EACH PANEL BOARD.DIRECTORY TO ACCURATELY LIST CIRCUIT NUMBER, LOCATION, TYPE OF OUTLETS INDICATE CONTROLLED ANDCONNECTED LOAD ON CIRCUIT4. PROVIDE LAMINATED, RIGID PLASTIC LABEL BELOW DIRECTORY WORDED AS FOLLOWS: INSTALLED BY (NAME OFTHE CONTRACTOR) (YEAR)5. PROVIDE EACH PANEL BOARD WITH GREEN CODED GROUND BAR, NOT CONNECTED TO NEUTRAL, FOR GREENEQUIPMENT GROUND WIRES. BACK BAR TO HAVE MINIMUM CAPACITY OF 11 TERMINAL WITH SOLDERLESS BOXLUGS FOR WIRE SIZE #12 MINIMUM TO #4 MAXIMUM. LOCATE BAR ADJACENT TO NEUTRAL BAR, BOLT OR WELD TOPANEL CAN.6. PROVIDE PLASTIC LABEL LISTING PANEL DESIGNATION, VOLTAGE AND PHASE ON INSIDE OF PANEL COVER ABOVEDIRECTORY.E. DISCONNECT SWITCHES (SHOP DRAWINGS REQUIRED):1. PROVIDE DISCONNECT SWITCHES, FUSED AND NON-FUSED AS REQUIRED BY CODES.A) SWITCHES NENA RATED DUTY, FED. SPEC. W-S-865CB) RATED 240 VOLTS FOR 208 VOLT SYSTEM, AND 600 VOLTS FOR 480 VOLT SYSTEM.2. EACH MOTOR, REMOTE FROM PANEL LOCATION, TO HAVE NON-FUSED DISCONNECT SWITCH OR BREAKER WITHINSIGHT OF MOTOR LOCATION. SAFETY SWITCHES SAME MANUFACTURER AS BRANCH CIRCUIT PANELBOARDS.EXTERIOR SWITCH NEMA 3R,F. BRANCH CIRCUIT WIRING:1. CONDUCTORS TO BE COPPER. NO WIRE SMALLER THAN NUMBER # L2 AWG ANY BRANCH CIRCUIT2. CONDUCTOR INSULATION, UNLESS OTHERWISE NOTED, TYPE THHN, INSULATION CODED AS FOLLOWS:A) 120/208 VOLT SYSTEM:(1) PHASE A, BLACK(2) PHASE B, RED(3) NEUTRAL, WHITE(4) TRAVELERS, PURPLE(5) GROUND, GREENB) 277/480 VOLT SYSTEM(1) PHASE A, YELLOW(2) PHASE B, ORANGE(3) PHASE C, BROWN(4) NEUTRAL, GRAY(5) TRAVELERS, 3 WAY, PINK(6) GROUND, GREEN3. SAME COLOR INSULATION FOR PARTICULAR PHASE OR PART OF CIRCUIT RUN WITH SAME COLOR THROUGHOUTJOB. COLOR CODE INTEGRAL PART OF INSULATION. PAINTED OR TAPED CONDUCTORS NOT ACCEPTED EXCEPTAS FOLLOWS:A) WIRE SIZED NO. 1 AND LARGER MAY BE COLOR CODED BY WRAPPING WITH 3M TAPE (NO. 35) FOR ENTIRELENGTH OF EXPOSED AREA IN GUTTERS, PANEL CANS, SWITCHBOARDS, OR WIREWAYS.4. SPLICES OR JOINTS IN CONDUCTORS MECHANICALLY AND ELECTRICALLY SOUND, MADE IN OUTLET BOXES ONLY,EXCEPT BALLAST CONNECTION. ALL JOINT MADE USING TYPE Y, G, R, B SCOTCH-LOCK CONNECTORS ONLY.A) AT EACH OUTLET, LOOP OF WIRE 8-INCHES LONG LEFT FOR CONNECTION TO DEVICE.B) FLUORESCENT FIXTURE WIRING TO CONFIRM TO NATIONAL ELECTRIC CODE, ARTICLE 410-24; USE THHNINSULATION.5. OUTLETS CONNECTED AS INDICATED ON PLANS, ALTERING CIRCUITS NOT PERMITTED WITHOUT WRITTENAPPROVAL OF ENGINEER.6. ALL BRANCH CIRCUIT AND FEEDER RACEWAYS CONTAIN GREEN CODED, TW, GROUND WIRE IN ADDITION TOOTHER CONDUCTORS.G. WIRING DEVICES (SHOP DRAWINGS REQUIRED):1. PROVIDE ALL WIRING DEVICES INDICATED ON PLANS. COLOR OF DEVICE SELECTED BY ARCHITECT AT TIME OFSUBMITTAL.H. DEVICE PLATES (SHOP DRAWINGS REQUIRED):1. WIRING DEVICES TO HAVE PLASTIC TYPE PLATE AS REQUIRED BY DEVICE. COLOR BY ARCHITECT. OUTLETWITHOUT DEVICES, EXCEPT TELEPHONE, TO HAVE BLANK PLATE. PLATES HOLD IN PLACE BY OVAL HEAD,STAINLESS STEEL SCREWS, MATCHING PLATE BY COLOR.I. FIXTURES (SHOP DRAWINGS REQUIRED):1. PROVIDE FIXTURES AS LISTED ON FIXTURE SCHEDULE, COMPLETELY WIRED AND LAMPED WHERE DESIGNATEDON DRAWINGS. CORRELATE SUPPORT AND MOUNTING METHOD WITH ALL SUBCONTRACTORS INVOLVED WITHSURROUNDING SURFACE.A) FIXTURE SUPPORT BOLTED OR WELDED TO SUPPORTING SURFACE.2. FLORESCENT FIXTURE BALLAST CBM CERTIFIED, SOUND RATING A WITH AUTOMATIC THERMAL RESET.JEFFERSON, ADVANCE, SOLA OR APPROVED EQUAL ENERGY SAVING TYPE.M. GUARANTEE AND SERVICE1. CONTRACTOR AND MANUFACTURER TO GUARANTEE EQUIPMENT FOR ONE (1) YEAR AFTER FINAL ACCEPTANCE2. CONTRACTOR TO GRANTEE MATERIAL AND WORKMANSHIP FOR ONE (1) YEAR AFTER FINAL ACCEPTANCE ANDREPLACE ANY DEFECTS WITHOUT EXPENSE TO OWNER. FURNISH SERVICE FOR ONE (1) YEAR AFTERACCEPTANCE. SERVICE TO INCLUDE LUBRICATION, CLEANING NECESSARY ADJUSTMENTS AND/ORREPLACEMENTS, PREVENTATIVE MAINTENANCE, ETC.3. LIGHT BULB REPLACEMENT LIMITED TO 30 DAYS.N. SUBMITTALS1. WITHIN FIVE (5) DAYS AFTER AWARD OF CONTRACT THE CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERYOF ALL MATERIALS AND EQUIPMENT CONCERNED WITH THIS PORTION OF THE WORK. WITHIN TEN (10) DAYSAFTER AWARD OF CONTRACT SUBMIT TO ENGINEER, IN QUADRUPLICATE, A STATEMENT OF CONFIRMATIONLISTING EQUIPMENT SUPPLIER, DATE ORDERED AND DELIVERY DATE. WHERE CHOICE OF MANUFACTURER ISGIVEN TO THE CONTRACTOR, LIST THE ONE ORDERED. THE FOLLOWING ITEMS MUST BE INCLUDED IN SUBMITTALLETTER: PANELS, SWITCHBOARD, DISCONNECTS, STARTERS, WIRE, CONDUIT, ELECTRIC METALLIC TUBING,OUTLET BOXES, DEVICES, PLATES, PLASTIC NAME PLATES, SPECIAL PURPOSE EQUIPMENT AND LIGHTINGFIXTURES.2. SHOP DRAWINGS TO BE SUBMITTED NO LATER THAN FORTY-FIVE (45) DAYS AFTER AWARD OF CONTRACT ANDPRIOR TO INSTALLATION OF MATERIAL REQUIRING APPROVAL. SHOP DRAWINGS ARE TO BE SUBMITTED COMPLETETHROUGH THE GENERAL CONTRACTOR AT ONE TIME. INTERMITTENT OR INCOMPLETE SUBMITTALS WILL NOT BECONSIDERED. MATERIAL OR EQUIPMENT REQUIRING SHOPS DRAWINGS APPROVAL IS NOT TO BE INSTALLED ONPROJECT UNTIL APPROVED SHOP DRAWINGS HAVE BEEN RETURNED BY THE ARCHITECT/ENGINEER.0. INSPECTIONS1. DURING THE PROGRESS OF THE WORK, THE ENGINEER, OR OWNER'S REPRESENTATIVE, WILL MAKEOBSERVATIONS AT THE SITE TO DETERMINE CONFORMATION OF WORK WITH PLANS, SPECIFICATIONS AND INTENTTHEREOF. DEFICIENCIES, VIOLATIONS AND INCORRECT WORKMANSHIP OR MATERIALS AND EQUIPMENT ANDCORRECTIVE ACTION THEREFORE WILL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR, FOR HISIMMEDIATE REMEDIAL ACTION.P. INTERRUPTION OF EXISTING SERVICE1. 48 HOURS ADVANCE NOTICE IS REQUIRED FOR OUTAGES ON FEEDER AND BRANCH CIRCUIT CONSIDERED VITALTO OPERATION BY OWNER, CONTRACTOR SHALL REQUEST SUCH OUTAGE, WITH ANTICIPATED DURATIONTHEREOF, IN WRITING FROM OWNER AND SHALL OBTAIN OWNER'S PERMISSION THEREFORE.Q. SAMPLES1. PHYSICAL SAMPLES OF MATERIAL AND EQUIPMENT PROPOSED FOR INSTALLATION ON THIS PROJECT SHALL BESUBMITTED TO ARCHITECT/ENGINEER UPON REQUEST.2. SAMPLES SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR WITH ALL SHIPPING AND HANDLINGCHARGES PREPAID. ANY EXPENSE INCURRED IN SECURING, DELIVERY AND RETURN OF SAMPLES ISRESPONSIBILITY OF CONTRACTOR. SAMPLES SHALL BE DELIVERED TO LOCATION DESIGNATED BYARCHITECT/ENGINEER. IDENTIFY SAMPLE WITH SHIPPING TAG, WIRED IN PLACE, CONTAINING THE FOLLOWINGINFORMATION:A) NAME OF PROJECT.B) NAME OF CONTRACTOR.C) SPECIFICATION SECTION NUMBER COVERING SAMPLE.D) MANUFACTURER'S NAME AND CATALOG NUMBER.E) DATE SUBMITTED.3. SAMPLES SHALL REMAIN THE POSSESSION OF CONTRACTOR EXCEPT AS FOLLOWS:A) APPROVED SAMPLES, WITHOUT PHYSICAL DAMAGE, MAY BE INSTALLED ON THE PROJECT.B) SAMPLES NOT CALLED FOR WITHIN 14 DAYS AFTER NOTIFICATION WILL BE DISPOSED OF BY THEARCHITECT/ENGINEER.R. SPARE PARTS AND TOOLS1. FURNISH TO THE OWNER, AND OBTAIN RECEIPT FOR IT, THE FOLLOWING:A) ONE SET OF FUSES FOR EACH SIZE AND TYPES INSTALLED ON PROJECT, INCLUDING RELAYS FOR MAGNETICSTARTERS.B) TWO KEYS EACH FOR PANEL LOCKS, WEATHERPROOF OUTLETS, PADLOCKS, TERMINAL CABINETS, ETC.C) SPECIAL TOOLS FOR FIXTURES, PANELS, FIRE ALARM SYSTEM, TAMPERPROOF SCREWS, ETC. ALL ITEMS TOBE IDENTIFIED.S. FINAL INSPECTION AND TESTS1. AS PRECEDENT TO FINAL INSPECTION AND ACCEPTANCE THE CONTRACTOR SHALL:A) HAVE ALL PREVIOUSLY LISTED DEFECTS CORRECTED.B) COMPLETE ALL WORKC) TEST ALL SYSTEMS AND HAVE DATA ON SUCH TESTD) HAVE ALL DIRECTORIES, LABELS AND INSTRUCTIONS.E) COMPLIED WITH APPLICABLE PARAGRAPHS OF THIS SECTION.2. FURNISH ADEQUATE MECHANICS AND PERSONNEL TO OPERATE SYSTEMS, MAKE ADJUSTMENTS, AND ASSISTWITH FINAL INSPECTION AS DIRECTED BY ARCHITECT/ENGINEER.ELECTRICAL WORKPART 1 - PRODUCTSA. CONDUIT:CONDUIT SHALL BE PROVIDED AS FOLLOW, UNLESS OTHERWISE NOTED:ELECTRICAL METALLIC TUBING (EMT): PROVIDE IN STUD AND HOLLOW MASONRY WALLS, ABOVE SUSPENDED ANDFURRED CEILING, AND EXPOSED IN DRY LOCATIONS. MAXIMUM ID SHALL BE 2". ALL FITTING SHALL BE STEELCOMPRESSION TYPE. RIGID CONDUIT AND ELECTRIC METALLIC TUBING AS MANUFACTURED BY ONE OF THEFOLLOWING (OR APPROVED EQUAL): A) ARMCO, B) REPUBLIC STEEL, C) TRIANGLE CONDUIT AND WIRE COMPANY, D)K. PORTER COMPANY, E) STEEL CITY, F) WHEATLAND TUBE.FLEXIBLE METAL CONDUIT: PROVIDE FOR CONNECTIONS FROM JUNCTION BOX TO LIGHT FIXTURE IN ACCESSIBLECEILINGS, (MAXIMUM RUN LENGTH OF 6' 0") AND ALL TERMINATION TO EQUIPMENT SUBJECT TO VIBRATION.(MAXIMUM RUN LENGTH OF 4' 0"). ALL FITTINGS SHALL BE APPLETON AST SERIES OR APPROVED EQUAL.LIQUID-TIGHT SHALL BE USED IN DAMP OR WET LOCATIONS AND FOR EQUIPMENT CONTAINING LIQUIDS. ALL FITTINGSSHALL BE O.Z. GEDNEY AKC SERIES OR APPROVED EQUAL.PLASTIC CONDUIT AS MANUFACTURED BY ONE OF THE FOLLOWING: A. CARLON PLASTIC PRODUCTS CORP. B)CANTEX PLASTIC PRODUCTS C) HATFIELD WIRE AND CABLE COMPANY.A NYLON PULL WIRE SHALL BE INSTALLED IN ALL EMPTY CONDUITS. IDENTIFY INTENDED USE AT BOTH ENDS.B. COUPLINGS AND CONNECTORS:1. COUPLINGS AND CONNECTOR MANUFACTURED BY ONE OF THE FOLLOWING (OR APPROVED EQUAL): A)APPLETON ELECTRIC COMPANY, B) RACO C), STEEL CITYC. OUTLET BOXES:1. GALVANIZED, STAMPED STEEL, 4-INCHES SQUARE BY 1-1/2 INCHES DEEP MINIMUM SIZE FOR WALL OUTLETS,MANUFACTURED BY, A) APPLETON ELECTRIC COMPANY, B) RACE ALL STEEL EQUIPMENT, C) STEEL CITY2. FLOOR BOXES: HUBBELL #B-2536 WITH S-3182 BRASS CARPET FLANGE AND S-3925 FLAP TYPE COVER FOR DUPLEXRECEPTACLE.D. PANELBOARDS:1. SQUARE-D, GENERAL ELECTRIC OR SIEMENS.E. WIRE:1. WIRE FOR THIS PROJECT AS MANUFACTURED BY ONE OF THE FOLLOWING: A) ANACONDA, B) GENERAL CABLECOMPANY, C) HATFIELD WIRE AND CABLE, D) REYNOLDS METAL COMPANY, E) SIMPLEX WIRE AND CABLE, F)TRIANGLE CONDUIT AND WIRE COMPANY OR APPROVED EQUALF. WIRING DEVICES:1. SINGLE OR THREE WAY DIGITAL SWITCH SHALL BE RAISE/LOWER SWITCHES WITH LOCAL CONTROL OF LIGHTINGZONE. SWITCH MAY BE PROGRAMMED TO CONTROL ANY RELAY, DIMMER OR PANEL.2. RECEPTACLE, DUPLEX (HUBBELL #5262, ARROW HART #5262).3. RECEPTACLE GFI (ARROW HART GF5242-I WITH 4501 COVER, HUBBELL GF5262-I WITH WP-26 COVER)G. SURGE PROTECTION DEVICE:1. ADVANCED PROTECTION TECH. "TE/XGA SERIES"2. CURRENT TECHNOLOGY "TG SERIES"3. INNOVATIVE TECHNOLOGY "PTX SERIES"4. SQUARE D SURGELOGIC "EMA SERIES" 5. GENERAL ELECTRIC "TRANQUELL SERIES"ELECTRICAL GENERAL PROVISIONPART 1 - GENERALA. GENERAL CONDITIONS AND REQUIREMENTS:THIS WORK IS SUBJECT TO THE GENERAL CONDITIONS AND THE GENERAL REQUIREMENTS BOUND THEREIN. THEFOLLOWING CODES AND REGULATIONS (LATEST VERSION) SHALL GOVERN THE EXTENT AND INSTALLATION OFELECTRICAL WORK UNLESS MORE STRINGENT REQUIREMENTS ARE SHOWN ON THE DRAWINGS OR SPECIFIEDHEREIN:A) 2014 N.E.C., F.B.C. 6TH EDITION 2017.B) NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS (NFPA 72, 2013 EDITION)C) UNDERWRITERS LABORATORIES, INC (UL)D) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)E) APPLICABLE LOCAL AND STATE BUILDING CODESB. SCOPE:1. THE WORK OF THIS DIVISION CONSISTS OF FURNISHING ALL PLANT LABOR, EQUIPMENT, SUPERVISION,APPLIANCE, MATERIALS AND PERFORMING ALL OPERATIONS REQUIRED TO COMPLETE ALL ITEMS OF WORK INACCORDANCE WITH THESE SPECIFICATIONS, APPLICABLE DRAWINGS AND ALL OTHER APPLICABLE PORTIONS OFTHE COMPLETE CONTRACT DOCUMENTS.2. THE WORK PROVIDED UNDER THIS DIVISION SHALL INCLUDE ALL LABOR, MATERIALS, PERMITS, INSPECTIONS ANDRE-INSPECTION FEES, TOOLS, EQUIPMENT, TRANSPORTATION, INSURANCE, TEMPORARY PROTECTION,TEMPORARY LIGHTING, SUPERVISION AND INCIDENTAL ITEMS ESSENTIAL FOR PROPER INSTALLATION ANDOPERATION, EVEN THOUGH NOT SPECIFICALLY MENTIONED OR INDICATED BUT WHICH ARE USUALLY PROVIDEDOR ARE ESSENTIAL FOR PROPER INSTALLATION AND OPERATION OF ALL ELECTRICAL SYSTEMS AS INDICATED INTHE CONTRACT DOCUMENTS.C. SUBSTITUTIONS/APPROVED EQUAL:1. PROVIDE ONLY UL LABELED PRODUCTS (WHERE APPLICABLE) OF TYPES INDICATED. ALL MATERIALS SHALL BENEW AND IN PERFECT CONDITION. NOTWITHSTANDING ANY REFERENCE IN THESE DRAWINGS TO ANY ARTICLE,DEVICE, PRODUCT, MATERIAL, FORM OR TYPE OF CONSTRUCTION BY NAME, MAKE OR CATALOG NUMBER, SUCHREFERENCES SHALL BE INTERPRETED AS ESTABLISHING A STANDARD OF QUALITY AND SHALL NOT BECONSTRUED AS LIMITING CONDITION. THE CONTRACTOR IN SUCH CASES MAY AT HIS OPTION USE ANY ARTICLE,DEVICE, PRODUCT, MATERIAL, FORM OR TYPE OF CONSTRUCTION WHICH IN THE JUDGMENT OF THEARCHITECT/ENGINEER, EXPRESSED IN WRITING, IS EQUAL TO THAT SPECIFIED.2. COST SAVINGS SHALL BE FORWARDED TO THE OWNER.D. FEES, PERMITS AND REGULATIONS:1. CONFORM TO ALL GOVERNING CODES, ORDINANCES OR REGULATIONS OF CITY, COUNTY, AND STATE HAVINGJURISDICTION. WHERE LOCAL CODES ARE NOT APPLICABLE, CONFORM TO NATIONAL ELECTRIC CODE, LATESTREVISION.2. BID WORK TO CONFORM TO CODE AT NO ADDITIONAL EXPENSE TO OWNER.E. CONTRACTOR'S RESPONSIBILITIES:1. COORDINATE WORK WITH OTHER TRADES, POWER AND TELEPHONE COMPANIES2. COORDINATE WORK SCHEDULE AND MATERIAL DELIVERY.3. PROVIDE A COMPETENT SUPERINTENDENT IN CHARGE OF WORK AT ALL TIME. REPLACE SUPERINTENDENT NOTDEEMED COMPETENT BY ARCHITECT. DO NOT WITHDRAW OR CHANGE SUPERINTENDENT WITHOUT PRIORAPPROVAL OF ARCHITECT.4. PROVIDE QUALIFIED MECHANICS. INSTALL MATERIALS AND EQUIPMENT IN NEAT, WORKMANLIKE MANNER.REMOVE AND REPLACE ANY MATERIAL OR EQUIPMENT, WHICH IS IMPROPERLY INSTALLED, OR DAMAGED IN THEOPINION OF THE ARCHITECT, AT CONTRACTOR’S EXPENSE.5. EXAMINE WORK OF OTHERS. NOTIFY ARCHITECT IMMEDIATELY IN WRITING IF ANY CONDITION EXISTS WHICH WILLPREVENT SATISFACTORY INSTALLATION OF MATERIALS OR EQUIPMENT. STARTING OF WORK WITHOUTNOTIFICATION INDICATES ACCEPTANCE AND SUBSEQUENT CHANGES REQUIRED WILL BE AT CONTRACTOR'SEXPENSE.6. THE INTEGRITY OF FIRE-RATED PARTITIONS SHALL BE MAINTAINED AROUND PENETRATING ELECTRICALELEMENTS. FIRE-RATED SEALANT, SLEEVES, ESCUTCHEONS AND SIMILAR UNITS SHALL BE PROVIDED WHEREREQUIRED BY REFERENCED CODES AND AUTHORITIES HAVING JURISDICTION. ALL PENETRATIONS IN RATED ASSEMBLIES SHALL BE PROTECTED IN ACCORDANCE TO SECTION 714 OF FBCB.F. INTERPRETATION OF DRAWINGS1. THE DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EXACT LOCATIONS OF CONDUIT RUNS,OUTLET BOXES, JUNCTION BOXES, PULL BOXES, ETC. THE LOCATIONS OF EQUIPMENT, APPLIANCES, FIXTURES,CONDUIT, OUTLETS, BOXES AND SIMILAR DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE ONLY. EXACTLOCATIONS SHALL BE AS ACCEPTED BY THE ENGINEER DURING CONSTRUCTION. OBTAIN IN THE FIELD ALLINFORMATION RELEVANT TO THE PLACING OF ELECTRICAL WORK AND IN CASE OF INTERFERENCE WITH OTHERWORK, PROCEED AS DIRECTED BY THE ENGINEER AND PROVIDE ALL LABOR AND MATERIALS NECESSARY TOCOMPLETE THE WORK IN AN ACCEPTABLE MANNER.2. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND DURING CONSTRUCTION OF THE PROJECT AND DONOT PROCEED WITH THAT PORTION OF THE PROJECT, UNTIL A WRITTEN DEFINITIVE STATEMENT IS RECEIVEDPROVIDING CLEAR DIRECTION. IF A CONFLICT EXISTS BETWEEN THE CONTRACT DOCUMENTS AND ANYAPPLICABLE CODE OR STANDARD, THE MOST STRINGENT REQUIREMENT SHALL BE INCLUDED FOR THIS PROJECT.THE ENGINEER SHALL MAKE THE DECISION REGARDING QUESTIONABLE AREAS OF CONFLICT.3. COMPARE ALL DRAWINGS AND VERIFY FIGURES BEFORE LAYING OUT WORK AND "BE RESPONSIBLE FOR ANYERRORS WHICH MIGHT HAVE BEEN AVOIDED THEREBY. SPECIAL NOTICE SHALL BE TAKEN OF CODE REQUIREDELECTRICAL CLEARANCE AND ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF DISCREPANCIES.4. WHEN MEASUREMENTS ARE AFFECTED BY CONDITIONS ALREADY ESTABLISHED, CONTRACTOR TO TAKEMEASUREMENTS NOTWITHSTANDING GIVING SCALE OR FIGURE DIMENSIONS ON DRAWINGS.G. SERVICE AND METERING1. COMPANY: THE UTILITY COMPANY SERVING THIS PROJECT, WHICH WILL BE REFERRED TO AS THE UTILITYCOMPANY HEREIN.2. SERVICE: MAKE ALL ARRANGEMENTS WITH THE UTILITY COMPANY FOR OBTAINING A COMPLETE SERVICE. PAYALL CHARGES AND PROVIDE ALL LABOR AND MATERIAL FOR THE SERVICE. SERVICE SHALL BE OBTAINED AT 120/208 OR 277/480 VOLTS FROM THE UTILITY COMPANY. PROVIDE UNDERGROUND CABLES AND CONDUITS FORINCOMING SERVICES FROM THE UTILITY'S PAD MOUNTED TRANSFORMER TO DISTRIBUTION EQUIPMENT. INSTALLMETER SOCKET, AND PROVIDE CT CABINET AND WIRING. CONTRACTOR SHALL ALSO INCLUDE INSTALLATION COSTOF UTILITY REQUIRED CONDUITS FROM THE UTILITY POLE TO PAD MOUNTED TRANSFORMER.3. FEES: CONTACT THE UTILITY COMPANY TO DETERMINE IF ANY FEES, CHARGES OR COSTS WILL BE DUE THECOMPANY, AS REQUIRED FOR TEMPORARY POWER, PERMANENT POWER, INSTALLATIONS, HOOK-UPS, ETC. THISFEE, CHARGE OR COST SHALL BE INCLUDED IN THE BID PRICE.4. PAYMENT: PAY FOR ALL REQUIRED LICENSES, FEES AND INSPECTIONS. INCLUDE ALL COSTS IN THE PROPOSEDCONSTRUCTION COST SUBMISSION. THESE COSTS SHALL INCLUDE BUT NOT BE LIMITED TO ALL-APPLICABLETAXES, PERMITS, NECESSARY NOTICES, CERTIFICATES AND ALL COSTS REQUIRED TO OBTAIN IT.H. CUTTING AND PATCHINGTHE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL OPENING REQUIREMENTS WITH THE GENERALCONTRACTOR. GENERAL CONTRACTOR SHALL PROVIDE ALL OPENINGS AND CLOSE IT. IF GENERAL CONTRACTOR ISNOT PROPERTY INFORMED THIS DIVISION WILL PROVIDE OPENINGS AT HIS OWN EXPENSE. CUTTING OF STEEL,WOOD OR OTHER MAIN STRUCTURAL PARTS MUST BE APPROVED BY ARCHITECT PRIOR TO CUTTING.I. HANDLING OF MATERIALS AND EQUIPMENT1. RECEIVE, HOUSE, HANDLE AND DELIVER TO PROPER LOCATION, MATERIALS AND EQUIPMENT.2. PROTECT FROM DAMAGE, MOISTURE, DIRT, DEBRIS AND WORK OF OTHER TRADES. USE OF PAPER, CARDBOARD,OTHER FLIMSY MATERIAL WILL NOT BE PERMITTED. REPLACE OR REFINISH MARKED OR DAMAGED SURFACES TOSATISFACTION OF ARCHITECT/ENGINEER.J. CLEAN UP1. KEEP PREMISES FREE FROM ACCUMULATIONS OF WASTE MATERIAL OR RUBBISH.A) LEAVE PREMISES AND WORK IN CLEAN, ORDERLY CONDITION ACCEPTABLE TO ARCHITECT/ENGINEER.B) CLEAN ALL MATERIALS AND EQUIPMENT OF DIRT, DUST, PAINT, SPOTS, STAINS, SOIL MARKS, ETC. ANYMATERIAL IN LESS THAT NEW CONDITION WILL BE REPLACED AT CONTRACTOR’S EXPENSE.K. LABELS1. PROVIDE FOR ALL EQUIPMENT, APPARATUS, DISCONNECT AND REMOTE CONTROL SWITCHES, ETC., RIGID,LAMINATED, PHONEMIC LABELS, BLACK WITH WHITE LETTERS SELF ADHESIVE BACK. TAPE LABELS OR ADHESIVENOT PERMITTED.2. SPECIFIC EQUIPMENT (I,E, ELECTRICAL PANELS AND EQUIPMENT) SHALL BE IDENTIFIED WITH ONE INCH HIGH,3-INCHES LONG, 1/16-INCH THICK LABEL WITH L/4 -INCH LETTERS.L. AS BUILT DRAWINGS1. DURING PROGRESS OF WORK, KEEP ONE SET OF PRINTS OR JOB SHOWING ANY CHANGES FROM ORIGINALPLANS.2. UPON COMPLETION OF WORK; FURNISH ARCHITECT/ENGINEER WITH CLEAN SET OF LEGIBLE AND ACCURATELYMARKED PRINTS INDICATING ALL CHANGES FROM ORIGINAL PLANS.23.ELECTRICAL SIGN(S) TO BE IN COMPLIANCE WITH 2014 NEC ARTICLE 600.24.ELECTRICAL SIGN(S) TO BE IN COMPLIANCE WITH 2014 NEC ARTICLE 600.3 FOR LISTING.25.ELECTRICAL SIGN(S) TO BE IN COMPLIANCE WITH 2014 NEC ARTICLE 600.4(A) FOR MARKINGS.26.ELECTRICAL SIGN(S) SHALL HAVE A COPY OF MANUFACTURERS INSTALLATION INSTRUCTIONS ON SITE AS PER NECARTICLE 600.4 (E) FOR INSPECTION.F) ASHRAE STANDARDS 90.1 (2013)27.A FUNCTIONAL TEST OF THE LIGHTING CONTROL SYSTEM SHALL BE REQUIRED PER FBC ENERGY CONSERVATION SECTION 408.3. PRIOR TO PASSING FINAL INSPECTION, THE DESIGN PROFESSIONAL SHALL PROVIDE EVIDENCE THAT THE LIGHTING CONTROL SYSTEMS HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURES INSTRUCTIONS. FUNCTIONAL TESTING SHALL BE IN ACCORDANCE WITH SECTIONS C408.3.1.1 AND C408.3.1.2 FOR APPLICATION CONTROL TYPE.28. THE PLANS REFLECT SYSTEM VOLTAGES DROP AS PER FBC ENERGY CONSERVATION 2017 SIXTH EDITION C405.6.3. FEEDER CONDUCTORS ARE SIZED FOR A MAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN LOAD. BRANCH CIRCUIT CONDUCTORS ARE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD.REVISIONSPROJECT NUMBER:ARCHITECTURE, DESIGN & DRAWING SERVICES# AA 26001108BRIAN P. FREDLEY, ASSOC. AIA, PROJECT MANAGERDALLAS B. PEACOCK, AIA, ARCHITECT# AR 0009706207 FAIRVIEW AVENUE, DAYTONA BEACH, FL, 32114PH: (386) 257-0502 FX: (386) 257-1050E-MAIL: bpfdesign@cfl.rr.com WEBSITE: bpfdesign.netDATE:SHT NO.ARCHITECT'S / ENGINEER'S SEALSCALE: AS SHOWN#1325 S. Bumby Ave. Orlando, Florida 32806PH: (407) 896 7411 / FX: (407) 896 7412EMAIL: epgroup@att.netCA#8126MTF2003903/19/2020CURALEAF ATLANTIC BEACH - INTERIOR MODIFICATION MEDICAL MARIJUANA FACILITYE-4ELECTRICAL SPECIFICATIONSGENERAL CONTRACTOR: T.B.DPROJECT LOCATION: 763 ATLANTIC BEACH BOULEVARD, UNIT 1, ATLANTIC BEACH, FL 32233OWNER/DEVELOPER: CURTIS BARKMAN, DIRECTOR OF PROJECT MANAGEMENT, PALLIATECH, INC., 301 EDGEWATER PLACE, SUITE 405, WAKEFIELD, MA 01880 PH:(781)451-0160MOHSEN FARAJI, P.E. 43599