Loading...
763 Atlantic Blvd COMM20-0012 17 of 26 M1-MECHANICAL FLOOR PLANHC HC 30 CONSULTCONSULTCONSULTMANAGERMEN'SWOMEN'SBREAKVAULTCLSUNISEXB.O.H.OPEN RETAILRETAILCOUNTERATMDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEDISPLAY CASEHCHCBRANCH DUCT SIZE CHART0-100CFM101-150151-250251-380381-550551-750751-950BRANCHDUCT SIZE(Ø")68810121414SUPPLYBRANCHDUCT SIZE(Ø")RETURN8101012141616INTERIOR HELIX SHALL BE ALUMINUM.TYPE FLEX-MASTER NI-35MARKSERVICE & LOCATIONCOOLINGHEATINGOCCUPIEDUNOCCUPIEDCOOLING HEATING%RHTHERMOSTAT SCHEDULERETAIL SPACE78 72 80 60NOTES:1. CONTRACTOR SHALL COORDINATE EXACT OPERATIONAL TIMES WITH55OWNER/MANAGER PRIOR TO PROGRAMMING.MANAGER OFFICE78 72 80 60 55T1T2MECHANICAL SYMBOLSDUCT (DUCTWORK)DUCT (DUCTWORK) CONT.PIPING TYPESMISCELLANEOUSDRAWING/DETAIL REFERENCE KEYFLARED SPIN-IN WITH DAMPER ANDSHEET NUMBERIN-LINE 90 DEGREE DROP (RISE) IN DUCTDRAWING/DETAIL NUMBERRE: 3/M4.013M4.01REFER TOTURNING VANESINCLINED DROP IN DUCTINCLINED RISE IN DUCTSPLITTER DAMPER/W NECK SIZEDUCT EXTRACTORDUCT MOUNTED HEATING COIL5"NDNUPEXISTING TO BE REMOVEDPOINT OF NEW CONNECTIONLIMIT OF DEMOLITIONSUPPLY OR OUTSIDE AIR DUCT UPSUPPLY OR OUTSIDE AIR DUCT DOWNRELIEF OR EXHAUST AIR DUCT UPRETURN AIR DUCT UPRETURN AIR DUCT DOWNRELIEF OR EXHAUST AIR DUCT DOWNOVAL OR FLAT OVALSECTION MARK & PAGEROUNDRECTANGULAR MAIN WITH CONICAL TAP.ROUND DUCT BRANCH TAKE-OFF FROMFLEX DUCT (DIFFUSER CONNECTION).REQUIRED NECK SIZEREQUIRED CFMDUCT SIZE TRANSITION.2208"HHUMIDITY SENSORTO AIR DEVICE WITH CFMSA DUCT, SPIN-IN DAMPER, FLEX DUCTPNEUMATIC TUBING OR CONTROL WIRINGDRAWING NOTE REFERENCETEMPERATURE SENSORTSPACE THERMOSTATHUMIDISTATRECTANGULAR DUCT. SIZE INDICATED IN INCHES,DIFFUSER/GRILLE LABEL:RADIUS DUCT ELBOW -ROUND OR RECTANGULAR.90 DEGREE DUCT ELBOW.WITH 45 DEGREE BRANCH INLET.RECTANGULAR DUCT BRANCH TAKE-OFFDUCT SMOKE DETECTORUNDERCUT DOOR 1" - NECK SIZE (INCHES) - TYPE/DESIGNATION - AIRFLOW (CFM)FIRST NUMBER IS SIDE SHOWN.RIGID ROUND DUCT TO FLEXRETURN AIR DUCT.SUPPLY OR OUTSIDE AIR DUCTSINGLE LINE SUPPLY AIR DUCTWORKRELIEF OR EXHAUST AIR DUCT.24"X8"20"X12"RGREFRIGERANT HOT GASREFRIGERANT LIQUID LINERLCONDENSATE DRAIN (COLD) GRAVITYCDPATTERN. NO PATTERN SHOWN EQUALS 4-WAY.SUPPLY AIR SLOT DEVICEEXHAUST DEVICERETURN AIR DEVICEROUND DUCT. DIAMETER INDICATED IN INCHES.RETURN AIR SLOT DEVICE12"SUPPLY AIR DIFFUSER - ARROWS INDICATESINGLE LINE RETURN AIR DUCTWORK24"X8"24x24,CD220 CFMDUCT MOUNTED HUMIDIFIERDAMPER TYPE:MOTORIZED DAMPERFIRE DAMPER W/ACCES DOORFD/ADHAIR TRANSFER GRILLEXXXXFUTURE DUCT TO BE INSTALLEDEXISTING TO REMAINEXISTING TO REMOVEXXXXFIRE DAMPEROPPOSITE BLADE MANUAL DAMPERFIRE SMOKE DAMPER W/ACCES DOORFSD/ADBAROMETRIC BY-PASS DAMPER (BBD)BACKDRAFT DAMPER (BDD)SPIN-IN TAKE OFF-FITTING WITH DAMPER AND SCOOPSPIN-IN TAKE OFF-FITTING ONLYSPACE THERMOSTAT WITH REMOTE SENSOR(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)OCCUPANCY SENSOR.THERMOSTAT/HUMIDISTATA3M-2FDosSDTHTT/HBBDMMDBDDMPSMANUAL PULL STATION24"x24",CD120 CFM24"x24",CD120 CFM24"x24",CD300 CFM24"x24",CD300 CFM24"x24",CD300 CFM24"x24",CD300 CFM24"x24",CD300 CFM14"x12"6"x12"24"x24",CD120 CFM24"x24",CD100 CFM10"x12" 16"x12"24"x24",CD50 CFMø6"ø8"ø10"ø10"ø10"ø8"ø6"ø8"ø12"24"x24",TG100 CFM24"x24",TG100 CFMø12"24"x24",TG100 CFM24"x24",TG100 CFMø10"ø10"24"x24",TG100 CFM24"x24",TG90 CFMUCUC6"ø 8"ø6"øEF175 CFMEF275 CFMosos24"x24",CD200 CFM24"x24",CD200 CFM24"x24",CD175 CFM24"x24",CD300 CFM12"x12",CD50 CFMUC24"x24",CD175 CFM12"x12",CD50 CFM12"x12",CD50 CFMø6"ø6"12"x12"8"x12"18"x12"EF375 CFMosRTU15-TONRTU23-TONEXISTING 12"x12",EAL150 CFM6"ø12"x12",EAL75 CFMø6"ø10"ø8"ø10"ø8"ø8"24"x24",RAG300 CFM24"x24",RAG200 CFM24"x24",RAG200 CFM24"x24",RAG350 CFM18"x12" 12"x10"12"x12"20"x12"MDMD24"x24",RAG875 CFM(TYP. OF 2)24"x24",TG190 CFMNEWIU-19000 BTU/hOU-19000 BTU/h1"ø11222T124"x14"ø10"ø10"T2RTU15-TONRTU23-TONEXISTING11 1/4"ø345WEIGHT: 565 lbs6REVISIONSPROJECT NUMBER:ARCHITECTURE, DESIGN & DRAWING SERVICES# AA 26001108BRIAN P. FREDLEY, ASSOC. AIA, PROJECT MANAGERDALLAS B. PEACOCK, AIA, ARCHITECT# AR 0009706207 FAIRVIEW AVENUE, DAYTONA BEACH, FL, 32114PH: (386) 257-0502 FX: (386) 257-1050E-MAIL: bpfdesign@cfl.rr.com WEBSITE: bpfdesign.netDATE:SHT NO.ARCHITECT'S / ENGINEER'S SEALSCALE: AS SHOWN#1325 S. Bumby Ave. Orlando, Florida 32806PH: (407) 896 7411 / FX: (407) 896 7412EMAIL: epgroup@att.netCA#8126MTF2003903/19/2020CURALEAF ATLANTIC BEACH - INTERIOR MODIFICATION MEDICAL MARIJUANA FACILITYM-1MECHANICAL FLOOR PLANGENERAL CONTRACTOR: T.B.DPROJECT LOCATION: 763 ATLANTIC BEACH BOULEVARD, UNIT 1, ATLANTIC BEACH, FL 32233OWNER/DEVELOPER: : CURTIS BARKMAN, DIRECTOR OF PROJECT MANAGEMENT, PALLIATECH, INC., 301 EDGEWATER PLACE, SUITE 405, WAKEFIELD, MA 01880 PH:(781)451-0160Farshad Antikchi, P.E.#72998Reference NotesNumber Description1 CONDENSATE DRAIN SHALL BE DISPOSED IN DRYWELL OR OTHER PROPER LOCATION PERFBCP SECTION 314.2.1. AND FBCM SECTION 307.2.12 DUCTWORK SHALL BE FIBROUS GLASS DUCT.3 PROVIDE ALL NEW ROOFTOP UNITS WITH PRE-FABRICATED MINIMUM 14 INCH HIGHINSULATED ROOF CURBS.4 PROVIDE THE PIPE SUPPORTS FOR ALL PVC CONDENSATE PIPING SPACING AT A MAXIMUM4'-0" ON CENTER PER FBCM SECTION 305.4. SUPPORTS EQUAL TO KNUCKLEHEAD WITHPIPECLAMP.5 COORDINATE ALL RTU'S WITH THE APPROVED EQUIPMENT FURNISHED FOR LOCATIONS,AND OPENING SIZES REQUIRED IN THE ROOF BETWEEN THE STRUCTURAL MEMBERS ANDEQUIPMENT CURBS.6 EXISTING EQUIPMENT TO REMAIN. CONTRACTOR SHALL INSPECT AND VERIFY EXACTLOCATION.M-11/4" = 1'-0"1Mechanical- Floor PlanM-1 1/4" = 1'-0"2Mechanical- Roof Plan