Loading...
763 Atlantic Blvd COMM20-0012 21 of 26 Mesker Single Door! SHEET REVISION � 1 - 2 - 3 J - 4 - 5 - <D C 6 0 --� 7 - 8 .e - m 9 A 10 � -t 11 -�-0 2 6 1 6 2 5 1 5 1 K 52" MAX FRAME WIDTH 47.56" MAX ./1'V2'f ANEL WIDTH '-._4-AV / / / / / / / / ' / / / / @) DOUBLE DOOR TYP. ELEVATION TABLE OF CONTENTS SHEET DESCRIPTION TYPICAL ELEVATIONS, DESIGN PRESSURES, & GENERAL NOTES DOOR PANEL DETAILS ANCHOR OPTIONS VERTICAL CROSS SECTION HORIZONTAL CROSS SECTIONS HORIZONTAL CROSS SECTIONS ANCHORING DETAILS ANCHORING DETAILS HARDWARE OPTIONS COMPONENTS BILL OF MATERIALS & COMPONENTS "N" SERIES COMMERCIAL OUTSWING STEEL BULLET DOOR (LMI) 1.THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE CURRENT FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 2.DOORS RATED FOR LARGE MISSILE IMPACT AND DO NOT REQUIRE SHUTTERS. 3.ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON ELEVATIONS / DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 4.ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. 5.MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS. 6.METAL STRUCTURES NOT BY MESKER INC. MUST SUPPORT LOADS IMPOSED BY DOOR SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. 7.DOOR PANEL: MIN. 14 GA. (0.067" THK.) STEEL MIN. Fy = 45 KSI MIN. DOOR FRAME: MIN. 12 GA. (0.093" THK.) STEEL MIN. Fy = 45 KSI MIN. 8.DOORS WHICH UTILIZE OUTSWING THRESHOLD QOSH BY DLP (ITEM #78) MEET THE WATER INFILTRATION REQUIREMENTS FOR THE "HVHZ". WATER TEST PRESSURE= 0.15 x POSITIVE DESIGN PRESSURE 9.DOORS THAT DO NOT MEET THE WATER INFILTRATION REQUIREMENTS FOR THE "HVHZ" SHALL BE INSTALLED ONLY IN NON-HABITABLE AREAS OR HABITABLE LOCATIONS PROTECTED BY AN OVERHANG OR CANOPY SUCH THAT THE ANGLE BETWEEN THE EDGE OF CANOPY OR OVERHANG TO SILL IS LESS THAN 45 DEGREES. 10.OTHER DOOR PANEL CONFIGURATIONS AVAILABLE PER REQUEST TO MANUFACTURE NOTES: EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. OVERALL FRAME SIZE WIDTH HEIGHT 52"100" DESIGN PRESSURE (PSF) POSITIVE NEGATIVE +65.0 -65.0 SEE SHEET 9 FOR ADDITIONAL DESIGN PRESSURE REQUIREMENTS DUE TO HARDWARE COMPONENT SELECTION c::: (1)0 WO a:: 0 W....1 Cl) w = w I- 1-w Cl) ::J (!) ::, z � 3: Cl) I­:, u_jO _J 1- MESKER DOOR INC. 3440 Standwood Blvd. Huntsville, AL 35811 PH: (256) 851-6670 enwl­o z ....I w z w (.') cd z 0 ....I en z w >­OJ Cl) z 0 z Cl) > w 0 j::: Ct'. (.) Cl) w 0 �--... DWG#: MDI013 SHEET: 1 OF 11