Loading...
763 Atlantic Blvd COMM20-0012 6 of 26 A005_life safetyREPLACE EXI' BROKEN DUI ENCLOSURE (UNDER SEPE -A�LIFE SAFETY PLAN - AU SCALE: 114"= I'-0" CONSTRUCTION TYPE OF CONSTRUCTION: 2B SPRINKLERED OR NON-SPRINKLERED: NON-SPRINKLERED MAX HEIGHT: 2 STORIES ACTUAL BUILDING HEIGHT: I STORY MAX FLOOR AREA: .............................. 12,500 S.F. PER TABLE 506.2 A. AREA MODIFICATION INCREASE ................ 0 S.F. (20' OPEN SIDES ON 4 SIDES OF BUILDING) B. OCCUPANCY AREA MODIFICATION .............N/A TOTAL ALLOWABLE AREA : MAX. FLOOR AREA + THE SMALLER OF A OR B: 12,500 FIRE PROTECTION MINIMUM INTERIOR FINISH CLASS MINIMUM FIRE PROTECTIVE EXITS: A EXIT ACCESS: B OTHER: C RESISTANCE OPENING FIRE WALLS & BARRIERS: I -HOUR I HOUR 2 -HOUR 1-1/2 HOUR 3 -HOUR 3 HOUR 4 -HOUR 3 HOUR FIRE PARTITIONS: I -HOUR 45 MINUTE* (*20 MINUTE IN RATED CORRIDORS) APPLICABLE CODES 6th EDITION (2017) FLORIDA BUILDING CODE - BUILDING 6th EDITION (2017) FLORIDA BUILDING CODE - EXISTING BUILDING 6th EDITION (2017) FLORIDA BUILDING CODE - ACCESSIBILITY 6th EDITION (2017) FLORIDA BUILDING CODE - ENERGY CONSERVATION 6th EDITION (2017) FLORIDA BUILDING CODE - FUEL - GAS 6th EDITION (2017) FLORIDA BUILDING CODE - MECHANICAL 6th EDITION (2017) FLORIDA BUILDING CODE - PLUMBING 6th EDITION (2017) FLORIDA FIRE PREVENTION CODE 2014 EDITION NATIONAL ELECTRICAL CODE OCCUPANCY OCCUPANCY / GROUP CLASSIFICATION: GROUP M (MERCANTILE) & GROUP B (BUSINESS) GROUP M (MERCANTILE): I PERSON PER 30 SF GROSS/ 714 SF = 23.8 PERSONS GROUP B (BUSINESS): I PERSON PER 100 SF GROSS/ 826 SF = 8.26 PERSONS GROUP S -I (BUSINESS): I PERSON PER 300 SF GROSS/ 595 SF = 1.98 PERSONS TOTAL = 34.04 PERSONS EXITS MINIMUM NUMBER OF EXITS: 2 PER FLOOR MAXIMUM TRAVEL DISTANCE: 75'-0" MAX FOR SINGLE EXITS 200'-0" MAX FOR 2 OR MORE EXITS MAXIMUM DEAD END CORRIDOR: 20'-0" MIN. CORRIDOR/ AISLE WIDTH: 44" IS A SEPARATE OR EMERGENCY SOURCE OF LIGHT REQUIRED? YES IS SPECIAL EGRESS PANIC HARDWARE REQUIRED? NO IS A MANUAL FIRE ALARM REQUIRED? NO OCCUPANCY TABLE SYMBOL GROUP AREA SF SF/PERSON PEOPLE GROUP M; MERCANTILE 714 SF @ 30 SF PER PERSON = 23.8 GROUP B; BUSINESS 826 SF @ 100 SF PER PERSON= 8.26 GROUP S-1; STORAGE 595 SF @ 300 SF PER PERSON = 1,98 OMITTED AREAS 173 SF TOTAL OCCUPANTS = 34,04 PERSONS GENERAL NOTES ALL GENERAL & SUB -CONTRACTORS TO FIELD VERIFY ALL DIMENSIONS, ELECTRICAL, WATER, SEWER AND GAS SERVICE LOCATIONS. ALL WORK MUST COMPLY WITH THE 2017 EDITION (EXPOSURE "B") OF THE FLORIDA BUILDING CODE SECT. 1609/ 137 MPH WIND LOAD N AND THE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION ALL DOOR & WINDOW OPENINGS TO MEET OR EXCEED DESIGN PRESSURE RANGE AS SPECIFIED ON SHEET TBL THE BUILDING RISK CATEGORY IS "11" E INTERNAL PRESSURE COEFFICIENT IS .18 IN ACCORDANCE WITH ASCE 7-10 r ALL GLAZING IS TO BE NON -IMPACT RESISTANT J REVISIONS LIFE SAFETY LEGEND NFPA COMPLIANCE FXQ CERTIFIED FIRE EXTINGUISHER 101:36.3.5.3 V EMERGENCY LIGHTING W/ BATT. BACKUP 101: 36.2.9 & 101: 7.9 NEW EXIT WI ILLUM. EXIT SIGN & 101: 36.2.8 & 101: 7.8 o EMERGENCY LIGHT COMBO 00 C0 o NEW WI ILLUM, EXIT SIGN & 101: 36.2.8 & 101: 7.8 EMERGENCY LIGHT COMBO o J AND MARKING MEANS OF EGRESS z (N) = NEW FIXTURE; (X) = EXISTING FIXTURE GENERAL NOTES ALL GENERAL & SUB -CONTRACTORS TO FIELD VERIFY ALL DIMENSIONS, ELECTRICAL, WATER, SEWER AND GAS SERVICE LOCATIONS. ALL WORK MUST COMPLY WITH THE 2017 EDITION (EXPOSURE "B") OF THE FLORIDA BUILDING CODE SECT. 1609/ 137 MPH WIND LOAD N AND THE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION ALL DOOR & WINDOW OPENINGS TO MEET OR EXCEED DESIGN PRESSURE RANGE AS SPECIFIED ON SHEET TBL THE BUILDING RISK CATEGORY IS "11" E INTERNAL PRESSURE COEFFICIENT IS .18 IN ACCORDANCE WITH ASCE 7-10 r ALL GLAZING IS TO BE NON -IMPACT RESISTANT J REVISIONS 0 0 00 Z J o z Q 00 C0 o Q � Q o J z � Oo W_ cn _ ( ' v J � WLAA Q cc ~ W z � Q � w V LAA O M V M CV cV W J Q = Q Q W _. 00 ~ V Z w � Z w Q L7 J Q � Z Q Q ~ V z w_ O 10 cC Cx__ oC L.L__ Q O w cC J � O W � V D Q Z m Q V Q Q 0 DO J DO pC M �C v '-p O z V w O o � � •'•w O V D � J � V Lj_j W W p z w O � � DESIGN INCORPORATED ARCHITECTURE, DESIGN, & DRAWING SERVICES # AA 26001108 BRIAN P, FREDLEY, ASSOC. AIA, PROJECT MANAGER DALLAS B. PEACOCK, AIA, ARCHITECT # AR 0009706 207 FAIRVIEW AVENUE, DAYTONA BEACH, FL 32114 PH: (386) 257-0502 FX: (386) 257.1050 E-MAIL; BFredley@BPFDesign,com WEBSITE; bpfdesign,com IRWITYKAN DATE; MARCH 11, 2020 SCALE; 114"=1' 0" 0 1' 3' 7' 10' ARCHITECT'S I ENGINEER'S SEAL SOF F�09 Digitally signed .�P.• �' B. PF . /� � 0.% by Dallas B. • ° — * — " • Peacock 13% AROW9706 :V �. �STFgED Date: AP��� 2020.04.23 10:06:29 —04'00'