801 Begonia St RES19-0304 Envelope Leakage Envelope Leakage Test Report �U,�FF�°I (Blower Door Test) 0,l �' • R402.4.1.2 Compliance �so�j4 ``��1�~ Tice o �' Permit#: RL;cJ I c� O3d`T Job Information ' 1 Builder: Ashlar Homes Community: ,A1ss\-lc, Q \ Lot: Address: 801 Begonia Street Unit: City: Atlantic Beach State: R Zip: 32233 Air Leakage Test Results Passing results must be 7ACH(50)or less Method for calculating buildingvolume: 987x 60 - 17798.5 = 3.33 0 Retrieved from architectural plans CFM(50) Building Volume ACH(50) OCode software calculated ✓ PASS FAIL O Field measured and calculated When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Certification of Test Results R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure or 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), F.S. or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Testing Company Company Name: Mcgowans Heating and air conditioning Phone: 904-278-0339 I hereby verify that the above Air Leakage results are in accordance with the 5th Edition Florida Building Code Energy Conservation requirements Section R402.4.1.2,Climate Zone 1 and 2. Date of Test: 4/14/2020 Signature of Tester: g Printed Name of Tester: Dennis Harrington License/Certification #: CMC1250075 Issuing Authority: Florida * Attach Cony of Certificate