Loading...
606 Coastal Oak Ln POOL20-0013 8 of8 Engineering ANSI 7 15 digital signed[2]_1?fr~~!l!~E!:'!r'i!t!!!~/NG / CLIENT AQUA DESIGN NAME DA VID ARNOLD ADDRESS 606 COASTAL OAK LN LOT: 143 AREA: ATLANTIC BEACH COUNTRY CLUB POOL MODE SPA MODE Suction Pressure Equipment Suction Pressure Equipment Pipe Size (in.) 2.5" 2" 2" 2.5" 2" 2" Pipe Length (100% flow) 32 16 15 60 50 15 #ELfittings 5 5 5 4 4 4 #T Run fittings 3 3 3 2 2 3 #T Branch f ittings 2 2 2 2 2 2 Gate Valves a a a a a a # 3 Way valves 0 a 2 0 0 3 ThiS calculatIOn assumes worst case with 100% suction from dram and none from skimmer. This calculation is conservative in that it omits the velocity head on the pressure side beyond the first split of return lines. Pump Curve J ANDY ePUMP VSSHP270AUT Filter: J ANDY CS250 250SF Heater: J ANDY JXI Return Fittings [TIPOOI + [TIspa Spa Jet Fittings[D Head loss based on Hazen-Williams equation, where c=150 Head Loss per 100 ft =0.2083 (l Oa/c) 1.852 *q 1.852 /d h 4.8655 DETAILED TDH POOL MODE DETAILED TDH SPA MODE Sum of Pipe Friction 2.2 B.O 17.0 29.0 43.B 61.4 2.6 9.3 19.7 33.5 50.6 Filter(s) 0.0 0.4 1.7 3.7 6.5 9.3 0.0 0.4 1.7 3.7 6.5 Return Fitting(s) 0.0 1.0 2.0 3.B 5.0 7.4 0.0 1.0 2.0 3.B 5.0 Salt System 0.0 0.7 1.4 2.3 3.3 4.3 0.0 0.7 1.4 2.3 3.3 Heater(s) 12.3 13.0 14.2 15.6 17.5 19.7 12.3 13.0 14.2 15.6 17.5 Sum TDH (FT H 2 O) 14.5 23.1 36.3 54.4 76.1 102.1 14.9 24.4 39.0 58.9 82.9 Flow (GPM) 20 40 60 BO 100 120 20 40 60 BO 100 300 ~)4 )l ~ ~I)I)I 1 4~ 250 350 300 .F A III ~( '[lE 71.0 9.3 7.4 4.3 19.7 111.7 120 if ~~ .It ~, 200 250 200 ,,~ 150 t:: 100 ~ c 50 I- o o I ~" ~~ ~, 50 ~~~ w ~ .~ 100 150 200 GPM 150 f100 ~~ ~~ It' ~ 50 c I- 0 ~~ .... ~~ 250 o 50 100 150 200 GPM 250 ~Sum TOH Pool _Pump Curve Pool • MAX FLOW _Sum TDH Spa _Pump Curve Spa • MAX FLOW POOL MODE SPA MODE MAXIMUM: 95 GPM @ 71' TDH 91 GPM @ 72' TDH RECOMMENDED MIN. BRANCH SUCTION RECOMMENDED MIN. TRUNK SUCT/ON TO EQUIP: 2.5" 2.5" --For Client Use Only - © 2019 Kimes Engineering and Management Services, Inc. 3990 SR 64 E I Bradenton, Florida 34208 I ph: (941)749-0311 kent@kimesengineering.com I P.E. 33678, CA. 27189 2.5" 2.5"