587 Timber Bridge Ln RES20-0116 6 of 10 HVAC load calculations_6 of 17Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-06 16:59:25Right-Suite® Universal 2019 19.0.18 RSU21735 Page 1 ...culations\Pujadas Residence (Air2Air Model).rup Calc = MJ8 Front Door faces: S 2020.002389Job:Project Summary 04-01-2020Date:Entire House Jose R. Flores Jr.By: Pujadas ResidencePlan:Apex 9000 Regency Square Boulevard, Suite 100, Jacksonville, FL 32211 Phone: (904) 821-5200 Fax: (904) 992-8700 Email: jose.flores@apextechnology.com Web: www.apextechnology.com Project Information John Merrill HomesFor: 11555 Central Parkway, Suite 1103, Jacksonville, FL 32224 Phone: 904-626-5100 587 Timber Bridge Lane Atlantic Beach, Fl. 32233 Lot 162 Atlantic Beach Country Clud Notes: Design Information Jacksonville IAP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F33 Outside db °F93Inside db °F70 Inside db °F75 Design TD °F37 Design TD °F18 Daily range M Relative humidity %50 Moisture difference gr/lb50 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh39849 Structure Btuh28345DuctsBtuh8964DuctsBtuh5953 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 Humidification Btuh0 Blower Btuh0PipingBtuh0 Equipment load Btuh48812 Use manufacturer's data yRate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh34298 Method Latent Cooling Equipment Load SizingBlower doorShielding / stories 3 (partial) / 1 50 Pa / 3446 cfmPressure / AVF Structure Btuh6332DuctsBtuh3868Central vent (0 cfm)Btuh0 CoolingHeating29242924Area (ft²)Equipment latent load Btuh10200 2953529535Volume (ft³)Air changes/hour 0.310.55 Equipment Total Load (Sen+Lat)Btuh44498 Equiv. AVF (cfm)151269 Req. total capacity at 0.70 SHR ton4.1 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTrade n/a Trade n/a Model n/a Cond n/aAHRI ref. n/a Coil n/a AHRI ref. n/aEfficiencyn/a Efficiency n/a Heating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 2020-Apr-06 16:59:25 Right-Suite® Universal 2019 19.0.18 RSU21735 Page 1 ...culations\Pujadas Residence (Air2Air Model).rup Calc = MJ8 Front Door faces: S 2020.002389Job:Building Analysis 04-01-2020Date:Entire House Jose R. Flores Jr.By: Pujadas ResidencePlan:Apex 9000 Regency Square Boulevard, Suite 100, Jacksonville, FL 32211 Phone: (904) 821-5200 Fax: (904) 992-8700 Email: jose.flores@apextechnology.com Web: www.apextechnology.com Project Information John Merrill HomesFor: 11555 Central Parkway, Suite 1103, Jacksonville, FL 32224 Phone: 904-626-5100 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Jacksonville IAP, FL, US 1837Design TD (°F)ft33Elevation: 5050Relative humidity (%)°N30Latitude: Outdoor:50.032.7Moisture difference (gr/lb)CoolingHeating Infiltration:9333Dry bulb (°F) Blower doorMethod)M(20-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 3446 cfmPressure / AVF7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 14.369942.1Walls 9.5464312.5Glazing 2.813856.5Doors 12.661271.7Ceilings 20.097582.72.7Floors 22.4109423.3Infiltration 18.48964Ducts 00Piping 00Humidification 00Ventilation 0Adjustments 100.048812Total Cooling Walls Glazing Doors Ceilings Infiltration Ducts Internal Gains % of loadBtuhBtuh/ft²Component 10.836961.1Walls 27.6947925.5Glazing 3.211045.2Doors 13.144981.2Ceilings 000Floors 8.729880.9Infiltration 17.45953Ducts 00Ventilation 19.26580Internal gains 00Blower 0Adjustments 100.034298Total Latent Cooling Load = 10200 Btuh Overall U-value = 0.206 Btuh/ft²-°F Data entries checked. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-06 16:59:26 Right-Suite® Universal 2019 19.0.18 RSU21735 Page 1 ...culations\Pujadas Residence (Air2Air Model).rup Calc = MJ8 Front Door faces: S 2020.002389Job:Load Short Form 04-01-2020Date: Entire House Jose R. Flores Jr.By: Pujadas ResidencePlan:Apex 9000 Regency Square Boulevard, Suite 100, Jacksonville, FL 32211 Phone: (904) 821-5200 Fax: (904) 992-8700 Email: jose.flores@apextechnology.com Web: www.apextechnology.com Project Information John Merrill HomesFor: 11555 Central Parkway, Suite 1103, Jacksonville, FL 32224 Phone: 904-626-5100 Design Information InfiltrationClgHtg Blower doorMethod9333Outside db (°F) 3 (partial) / 1Shielding / stories7570Inside db (°F) 50 Pa / 3446 cfmPressure / AVF1837Design TD (°F) M-Daily range 5050Inside humidity (%) 5033Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) (Rest of House)2924 48812 34298 1900 1900 (Unconditioned)745 0 0 0 0 Entire House 3669 48812 34298 1900 1900 Other equip loads 0 0 Equip. @ 1.00 RSM 34298 Latent cooling 10200 TOTALS 3669 48812 44498 1900 1900 2020-Apr-06 16:59:26 Right-Suite® Universal 2019 19.0.18 RSU21735 Page 1 ...culations\Pujadas Residence (Air2Air Model).rup Calc = MJ8 Front Door faces: S 2020.002389Job:Load Multizone Summary Report 04-01-2020Date: Jose R. Flores Jr.By: Pujadas ResidencePlan:Apex 9000 Regency Square Boulevard, Suite 100, Jacksonville, FL 32211 Phone: (904) 821-5200 Fax: (904) 992-8700 Email: jose.flores@apextechnology.com Web: www.apextechnology.com Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM ft³cfm Btuh/ft²ft³cfm Btuh/ft² 1.11510.31295354.02690.5529535(Rest of House) 00000000(Unconditioned) Entire House 29535 0.55 269 4.0 29535 0.31 151 1.1 Load and AVF Summary ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft²Btuh Btuh cfm cfm 619011062321152Mater Bath 54509741282109Bill's Closet 657311671881160Joy's Closet 93971676249183Laundry 94161689413161Kitchen 6611316263Pantry 375400677210280529Living 1179521172434264Dining 18110232762625205Bedroom 2 18811933873060218Bedroom 3 16617030054359161Study 8815221785Bath 2 9416716894279138Gallery 50599021503165Mud Room 791131417289498Foyer 6611316263Powder 26332947438447272Master Suite 1900190034298488122924(Rest of House) 00007452 Car Garage 0000745(Unconditioned) Entire House 3669 48812 34298 1900 1900 2020-Apr-06 16:59:26 Right-Suite® Universal 2019 19.0.18 RSU21735 Page 1 ...culations\Pujadas Residence (Air2Air Model).rup Calc = MJ8 Front Door faces: S 2020.002389Job:Component Constructions 04-01-2020Date:Entire House Jose R. Flores Jr.By: Pujadas ResidencePlan:Apex 9000 Regency Square Boulevard, Suite 100, Jacksonville, FL 32211 Phone: (904) 821-5200 Fax: (904) 992-8700 Email: jose.flores@apextechnology.com Web: www.apextechnology.com Project Information John Merrill HomesFor: 11555 Central Parkway, Suite 1103, Jacksonville, FL 32224 Phone: 904-626-5100 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Jacksonville IAP, FL, US 1837Design TD (°F)ft33Elevation: 5050Relative humidity (%)°N30Latitude: Outdoor:50.032.7Moisture difference (gr/lb)CoolingHeating Infiltration:9333Dry bulb (°F) Blower doorMethod)M(20-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 3446 cfmPressure / AVF7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12E-0sw: Frm wall, r-19 cav ins, 2"x6" wood frm, 16" o.c. stud 2.5219.00.068355n 4921.39893 7860.8914251.6219.00.068880e 2630.934771.6919.00.068283s 10081.3018282.3519.00.068777w 25491.1146242.0219.00.0682295all 16X19-13md: Knee wall, mtl roof mat, r-13 kw ins 0.07040n 370.92501.2532.0 1920.922611.2532.00.070208e 370.92501.2532.00.07040s 1920.922611.2532.00.070208w 4570.926221.2532.00.070496all Partitions 12C-0sw: Frm wall, r-13 cav ins, 2"x4" wood frm, 16" o.c. stud 3.3713.00.091519 6901.331748 Windows JM Homes Glass: 1 glazing, clr glz, Vinyl frm - Non impact, (U=0.33, SHGC=0.28); NFRC rated (SHGC=0.28); 8 ft head ht 63511.865912.200.33054n 146032.854312.200.33045e 41213.736612.200.33030s 482232.8179512.200.330147w 732926.6336412.200.330276all JM Homes SGD: 2 glazing, clr glz, Vinyl frm - Non impact, SGD (U=0.36, SHGC=0.28); NFRC rated (SHGC=0.28); 8 ft head ht 118112.3127913.300.36096n Doors 11G0: Door, wd pnl type 76515.995920.000.54048s 34015.942620.000.54021n 110415.9138520.000.54069all 11J0: Door, ovhd mtl type 00006.30.600144s Ceilings 16X19-0md: Attic ceiling, mtl roof mat, r-18 roof ins 0.4083669 44981.2361271.6719.0 Floors 22A-tpm: Bg floor, heavy dry or light damp soil, on grade depth 34.501.180283 009758 2020-Apr-06 16:59:26 Right-Suite® Universal 2019 19.0.18 RSU21735 Page 2 ...culations\Pujadas Residence (Air2Air Model).rup Calc = MJ8 Front Door faces: S