Loading...
587 Timber bridge Lane-RES20-0116 Hardie Soffit Panel Evaluation Guide-ESR-2273 14 of 17A Subsidiary of 0 000 Most Widely Accepted and Trusted ICC-ES Report ESR-2273 Issued 06/2016 This report is subject to renewal 06/2017. ICC-ES | (800) 423-6587 | (562) 699-0543 | www.icc-es.org ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. “2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence” Look for the trusted marks of Conformity! DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 06 12 13—CEMENTITIOUS REINFORCED PANELS DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 45 00—FIBER-REINFORCED CEMENTITIOUS PANELS REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CALIFORNIA 92337 EVALUATION SUBJECT: HARDIESOFFIT® AND CEMSOFFIT® EXTERIOR SOFFIT PANEL ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 3 1000 ICC-ES Evaluation Report ESR-2273 Issued June 2016 This report is subject to renewal June 2017. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council® DIVISION 06 00 00—WOOD, PLASTICS AND COMPOSITES Section 06 12 13—Cementitious Reinforced Panels DIVISION 07 00 00—THERMAL AND MOISTURE PROTECTION Section 07 45 00—Fiber-Reinforced Cementitious Panels REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CALIFORNIA 92337 (800) 942-7343 info@jameshardie.com EVALUATION SUBJECT: HARDIESOFFIT® AND CEMSOFFIT® EXTERIOR SOFFIT PANEL 1.0 EVALUATION SCOPE Compliance with the following codes:  2015, 2012 and 2009 International Building Code® (IBC)  2015, 2012 and 2009 International Residential Code® (IRC) Properties evaluated:  Physical Properties  Structural  Noncombustible Construction  Surface-burning characteristics  Thermal Resistance  Weather Protection 2.0 USES Hardiesoffit® and Cemsoffit® panels are used as exterior soffit covering of buildings of non-fire-resistance-rated construction. 3.0 DESCRIPTION Hardiesoffit® and Cemsoffit® panels are single-faced, cellulose fiber-reinforced cement (fiber-cement) sheets manufactured by the Hatschek process and cured by high-pressure steam autoclaving. The exterior soffit panels are identified as Hardiesoffit® (Cemsoffit®) panels and may be vented or unvented. The fiber-cement sheets comply with ASTM C1186 as Type A, Grade II, and have a flame-spread index of 0 and a smoke developed index of 5 when tested in accordance with ASTM E84. The sheets are classified as noncombustible when tested in accordance with ASTM E136. Thermal conductivity (K) and thermal resistance (R) values for the unvented products are shown in Table 2 based on ASTM C177 tests. When tested in accordance with ASTM E96, unvented products with a thickness of ¼ inch (6.4 mm) have demonstrated the permeance value given in Table 3 of this report. Soffit panels are available with either a woodgrain texture or a smooth unsanded surface. The exterior soffit products may be supplied unprimed or primed for subsequent application of a compatible primer and/or exterior-grade topcoat(s). Nominal soffit dimensions are noted in Table 1. 4.0 DESIGN AND INSTALLATION 4.1 Design: The maximum wind speeds, building heights and exposure categories applicable for Hardiesoffit® and Cemsoffit® panels are noted in Table 5. Vented soffit panels provide net free ventilation area as presented in Table 4 of this report. 4.2 Installation: Installation shall comply with this report and the manufacturer’s published installation instructions. A copy of the manufacturer’s published installation instructions this report must be available at the job site during installation. All panel edges must be supported be framing members. Panels must be attached with corrosion-resistant fasteners installed with a minimum 3/8 inch (9.5 mm) edge distance and minimum 2-inch (51 mm) clearance from corners. The panels must be installed with the long edge of the panel perpendicular to the joist framing and must be attached with fastener types, lengths, and spacings described in Table 5. Framing must include a subfascia, blocking, and/or ledger board to provide a nailing base along the dimension of the soffit. 5.0 CONDITIONS OF USE The Hardiesoffit® and Cemsoffit® exterior soffit panels described in this report comply with, or are suitable alternatives to what is specified in those codes listed in Section 1.0 of his report, subject to the following conditions: ESR-2273 | Most Widely Accepted and Trusted Page 2 of 3 5.1 The Hardiesoffit® and Cemsoffit® panels must be installed in accordance with this report and the manufacturer’s published installation instructions. In the event of a conflict between this report and the manufacturer’s published installation instructions, this report governs. 5.2 The Hardiesoffit® and Cemsoffit® soffit panel are manufactured under a quality control program with inspections by ICC-ES at the following locations: 5.2.1 Pulaski, Virginia 5.2.2 Tacoma, Washington 5.2.3 Waxahachie,Texas 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Fiber Cement Siding Used as Exterior Wall Siding (AC90), dated June 2012 (editorially revised September 2015). 7.0 IDENTIFICATION Hardiesoffit® and Cemsoffit® panels shall be identified by a stamp or label on the board bearing the name and address of the report holder (James Hardie Building Products), the product name (Hardiesoffit® or Cemsoffit®), and the evaluation report number (ESR-2273). TABLE 3—WATER VAPOR PERMEANCE VALUES FOR UNVENTED SOFFIT PRODUCTS Product Thickness (inch) Permeance (perms) 1/4 1.75 1 inch = 25.4 mm, 1 perm = 57 mg/(s•m2•Pa) TABLE 4—VENTILATION RATES FOR VENTED SOFFIT PRODUCTS Width (inch) NET FREE VENTILATION (in2 / linear ft) 53/4 and over 5.0 (64 cm2/m) 51/4 4.0 (64 cm2/m) 4 3.0 (64 cm2/m) 1 inch = 25.4 mm TABLE 1—STANDARD NOMINAL SOFFIT DIMENSIONS Product Type Width (inches) Length (feet) Thickness (inches) Hardiesoffit® Smooth (unvented) 4, 5, 6, 10, 12, 16, 24, 36 & 48 8, 9, 10 & 12 1/4 Hardiesoffit® Woodgrain (unvented) 4, 51/4 , 53/4, 6, 61/4, 71/4, 8, 81/4, 91/2, 10, 111/4, 111/2, 12, 151/4, 16, 24, 36 & 48 8, 9, 10 & 12 1/4 Hardiesoffit® Smooth (vented) 4, 6, 91/2, 10, 111/2, 12, 16 & 24 8 & 12 1/4 Hardiesoffit® Woodgrain (vented) 4, 51/4, 53/4, 6, 61/4, 71/4, 8, 81/4, 91/2, 111/2, 12, 16 & 24 8 & 12 1/4 Cemsoffit® Woodgrain (unvented) 4, 5, 6, 10, 12, 16, 24, 36 & 48 8, 9, 10 & 12 1/4 Cemsoffit® Woodgrain (vented) 4, 51/2, 53/4, 6, 61/2, 71/4, 8, 81/4, 91/2, 111/2, 12, 16 & 24 8 & 12 1/4 1 inch = 25.4 mm, 1 ft = 304.8 mm TABLE 2—K and R VALUES FOR UNVENTED SOFFIT PRODUCTS Product Thickness (inch) Actual Thermal Conductivity (Keff) Actual Thermal Resistance(Btu/h-ft2-°F) 1/4 7.80 0.13 1 inch = 25.4 mm, 1 Btu/h-ft2-°F = 5.678 W/m2-K ESR-2273 | Most Widely Accepted and Trusted Page 3 of 3 TABLE 5—MAXIMUM WIND SPEEDS FOR EXPOSURE CATEGORY (mph)2 2012 IRC, 2009 IBC/IRC, 2006 IBC/IRC (Basic Wind Speed, Vasd1,4,7 ) 2015 IBC/IRC, 2012 IBC (Ultimate Design Wind Speed, Vult5,6) EXPOSURE CATEGORY EXPOSURE CATEGORY Product Product Dimensions (in.) Fastener Type Fastener Spacing (in.) Frame Type Stud Spacing (in.) Building Height8 (ft.) B C D B C D Thick Max. Width Hardiesoffit® 1/4 48 4d common, 1½-in long 8 2 x 4 wood3 16 0-15 20 40 60 111 111 106 100 100 98 91 87 91 89 - - 143 143 137 130 130 126 117 112 118 115 - - Hardiesoffit® 1/4 48 4d common, 1½-in long 8 2 x 4 wood3 24 0-15 20 40 60 94 94 90 86 86 - - - - - - - 122 122 117 110 110 - - - - - - - Hardiesoffit® 1/4 48 6d siding nail 0.092-in shank x 2-in long x 0.235-in HD 4 2 x 4 wood3 24 0-15 20 40 60 139 139 133 126 126 122 114 109 114 112 105 101 179 179 172 162 162 158 147 141 147 144 135 131 Hardiesoffit® 1/4 16 0.083-in shank x 0.187” HD x 11/2--in long ring shank nail 8 2 x 4 wood3 16 0-15 20 40 60 185 185 177 168 168 163 152 146 152 149 140 135 239 239 229 217 217 211 196 188 197 192 181 175 Hardiesoffit® 1/4 16 0.083-in shank x 0.187” HD x 11/2--in long ring shank nail 8 2 x 4 wood3 24 0-15 20 40 60 186 186 178 169 169 164 152 146 153 150 141 136 240 240 230 218 218 211 197 189 198 193 182 175 Hardiesoffit® 1/4 24 0.083 shank x 0.187” HD x 11/2--in long ring shank nail 8 2 x 4 wood3 22.5 max 0-15 20 40 60 106 106 102 96 96 93 87 83 87 85 80 - 137 137 131 124 124 121 112 108 113 110 104 - Hardiesoffit® 1/4 24 6d siding nail 0.092-in shank x 2-in long x 0.235-in HD 4 2 x 4 wood3 24 0-15 20 40 60 144 144 138 131 131 127 118 113 119 116 109 105 186 186 178 169 169 164 152 146 153 150 141 136 Hardiesoffit® 1/4 24 6d common nail 0.113-in shank x 2-in long x 0.266-in HD 4 2 x 4 wood3 24 0-15 20 40 60 150 150 144 136 136 132 123 118 123 121 113 109 193 193 186 175 175 171 159 152 159 156 146 141 Hardiesoffit® 1/4 48 No 8 x 1-in long x 0.323 in HD ribbed bugle head screw 6 20 ga Min 35/8 in x 13/8 in metal C-stud 16 0-15 20 40 60 116 116 112 106 106 103 95 92 96 94 88 85 150 150 144 136 136 133 123 118 124 121 114 110 1 ft = 305 mm, 1 inch = 25.4 mm, 1 mph = 0.44 m/s. 1Wind speed design assumptions per Section 6.5, Method 2, of ASCE 7-05: I = 1.0, Kzt = 1, Kd = 0.85, GCpi = 0.18, GCp = -1.4. 2Installation must be in accordance with Section 4.2 of this report. 3Values are for species of wood having a specific gravity of 0.42 or greater. 4Vasd = nominal design wind speed. 5Vult = ultimate design wind speed 6Wind speed design assumptions per Section 30.4, of ASCE 7-10: Kzt = 1, Kd = 0.85, GCpi = 0.18, GCp = -1.4. 72015 and 2012 IBC Section 1609.3.1, Eq. 16-33, Vasd = Vult √0.6 8Building height equals the mean roof height (in feet) of a building, except that eave height shall be used for roof angle Θ less than or equal to 10° (2-12 roof slope).