Loading...
2434 SEMINOLE RD - SOLR19-0002 '3 C.--)L- — 0 C)C) --Z- 01^1.Lyr„ City of Atlantic Beach APPLICATION NUMBER is ***,,,A Building Department (To be a ned by the Building Department.) ¢ 800 Seminole Road ial _/'i'Z 07 1s' Atlantic Beach, Florida 32233-5445 \ l Phone(904)247-5826 Fax(904)247-5845 CO / z' �9 ,.Ti�, E-mail: building-dept@coab.us Date routed: � I ( l City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Z4 3 q— -S J / vtp (-1Department review required Yes No Lcti) uilding� Applicant: e7 OuSr-t [nS9 &Zoning ,Tree Administrator Project: C7) CU- 1'2[� IV ( S�2m Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By -- Florida Dept. of Environmental Protection C3) - Florida Florida Dept. of Transportation )' St. Johns River Water Management District ,,,�,� Army Corps of Engineers ` � v Division of Hotels and Restaurants V Division of Alcoholic Beverages and Tobacco Vim` Other: APPLICATION STATUS Reviewing Department First Review: ['Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING y� Reviewed by: /y< <� Date:7'a''q TREE ADMIN. Second Review: A roved as revised. ❑ pp ['Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: iiiipprCej ply ['Denied. fNot applicable Comments: J O Approved By Permit Desk Building Department City of AttantipaipJ. Date: Revised 05/19/2017 I1.,..A1'j;; ` ' \S, CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD \ ' .r ATLANTIC BEACH, FL 32233 (904) 247-5800 `---_-0.2191" BUILDING REVIEW COMMENTS Date: 7/2/2019 Permit#: RES19-0207 Site Address: 2434 SEMINOLE RD Review Status: denied RE#: 168354 0150 Applicant: SOLAR ENERGY LABS INC Property Owner: RICHARD BOEHME Email: MIKE.NEWMAN@ENERGYLABSINC.COM Email: navycat67@gmail.com Phone: 9046934555 Phone: 2484205445 9046934555 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Submit 2 copies of JEA's approval of the PV project. 2. Application will have to be resubmitted by the CVC License holder for this project. 3. Submit all information cut sheets/engineering reports for all attachments of the solar panels and their hardware for attachments. 4. Submit electrical schematics for the pv system. 5. Submit all information pertaining the pv equipment to be used for this project, including the signage and its placement required by JEA at equipment. 6. 2 copies required for all submittals. 7. There may be other request after resubmittals are submitted. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us � �'►''A, � .o� Cin vY�P✓1 TS 1.L•(c/ l�'� Resubmittal Notes: LAN I e, .41#4*-::�24.�5 f CITY OF ATLANTIC BEACH A s) 800 SEMINOLE ROAD J. ATLANTIC BEACH, FL 32233 ..- (904) 247-5800 1. 1-0.1119 .....,,,) BUILDING REVIEW COMMENTS Date: 7/22/2019 Permit#: SOLR19-0002 Site Address: 2434 SEMINOLE RD Review Status: denied RE#: 168354 0150 Applicant: SOLAR ENERGY LABS INC Property Owner: RICHARD BOEHME Email: MIKE.NEWMAN@ENERGYLABSINC.COM Email: Ity/VAVf(af 6) ©' Grnai.cdw+ Phone: 9046934555 Phone: 2484205445 9046934555 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Please submit 2 copies of the JEA Approval of solar system documents. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us �( -Ern ed Pcv) e a, ,- Co r- ,^'-e 'I\41- `7. 2 2 / 5 U Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. OFFICE COPY f/::_•----. .-,, Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHUGHTED IN GRAY .'5)7'':'-' IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 2434 Se minole Rd Atlantic Beach FL 32233 Permit Number: Legal Description 37-2S-29E 1.00 S/D Dewees Grant PT LOT 2 RECD O/R 17997-18 RE# R-168354-01S0 • Valuation of Work(Replacement Cost)$ 46644.00 Heated/Cooled SF Non-Heated/Cooled • Class of Work: DiNew ❑Addition DAlteration LiRepair ❑Move ❑Demo ❑Pool ❑Window/Door 1.1.1 • Use of existing/proposed structure(s): ❑Commercial f1SResidentlal 0 Z N • If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No 'd i Q ZZ • Will tree(s) ❑Y be removed in association with proposed oroiect? es(must submit separate Tree Removal Permit) ONo t2 z h Describe In detail the type of work to be performed: adding 15600 watts solar pv system 0 0 in Z U a0 ' zLI Fes'. a 0 I Florida Product Approval# for multiple products use product approval fore z cr Z Property Owner Information U u. Name Richard&Ingrid Boehme Address 2434 Seminole Rd CC Q Fes) Z • City Atlantic Beach State FL Zip 32233 Phone 248-420-5445 Q W E-Mail navycat67@gmail.com u'• Owner or Agent(If Agent,Power of Attorneyor Agency Letter Required) 0 w W g cY q )— LU }. 0. I Contractor Information r I- w o i Name of Company Solar Energy Labs Inc Qualifying Agent Michael D Newman U v) W • Address 1057 Ellis Rd#17 City Jax State FL Zip 32254 > CC t Office Phone 904-693-4555 Job Site Contact Number 1.1.1 i State Certification/Registration# CVC56672 E-Mail mike.newmannenerevlabsinc.com Architect Name& Phone# Engineer's Name&Phone# Workers Compensation Insurer American Insterstate OR Exempt❑ Expiration Date 05/26/2020 Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that ail work will be done in compliance with ail N r U.. applicable laws regulating construction and zoning. CL 0 m u `= Eal WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY O m fl cp RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND U o TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN TTORNEY BEFORE cp Q fco RECORDING Y NO CE OF COMMENCEMENT. f 'oma= o (Signature of 0 er or Agent) ` , ' nature of Contractor) ^ < V / / I Signed and sworn to(or affirme )before me th//' "' day of Sigrted and swyrn to(or affirmed)before me this/T day of A • t ,��,(_.��' i S b , :Cif it.e l L I.A;-�c�,),c-- -' A. -�1, / �� b -hay,, (fr. •.' vt.,'-c .-.-'i1- _2.-� le � + y�r Notary Public soli or r Notary Public State of Florida y Jennifer Bostic Jennifer Bostic My GG 292988 / My Commission GG 292988 personal) Known .R� A. ExprM 01/2i/2023� 'Personally Known OR •dj«w4 Expires 01212023 1 y cow t ]Produced Identification [ )Produced Identific. Type of Identification: Type of Identification: _-___., � I-ILI uur- r Doc # 2019106117 , OR BK 18783 Page 2350, Number Pages : 1 , Recorded 05/08/2019 09:51 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10. 00 NOTICE OF COMMENCEMENT / R C� (PREPARE IN DUPLICATE) Permit Nc. S OL 1 r �C Z" Tax Folio No. State of County of 0 i(VQ 1 _ To whom It may concern: The undersigned hereby Informs you that Improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information Is stated In this NOTICE OF COMMENCEMENT. • Legal description of property being improved: L E 4 /to 5'5 5`f- " 1.5•c, 3 7-.3, E (.oo, ,5 n6weES GRANT Ltr RECD cpq 1 .7 99 7 - l rs Address of property being Improved c9s.q- 3 4 S e/ki,t i C. Read -t A+1a11+(r✓ (death Ft _3 33 General description of improvements: adding 15600 watts grid tied solar system Owner N(C taei !3O e h rYi t _ Address `f 3 41- cS e fn i 17 c(r✓ Read A+Iclvt-FL &A Ft 3 3 Owner's interest in site of the improvement Homeowner Fee Simple Titleholder(if other than owner) Name Address Contractor Michad D.Newman CVC56672 Address 1057 Ellis Rd./t17 Jacksonville FL 32254 Phone No. 9o4-6a3-4555 Fax No.004-300-0773 Surety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienors Notice as provided in Section 713 06(2)0),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signeci, DATE 1/Z Before me this f7tday of . p L 01 in the Co.mty of vaL sl a of Fbr da,has pe Lu1� rp����at� _ • �ereinDy IIiseir/hersetf and affirms a i- .10 ��ein / are true arc accurate f VVidtr\ STATE OF FLORIDA L Corm*GG039483 " Expires 10/1712020 aaw. a Notary Public M Large.Stale of CorWy of�• My commission expires' Personally Known - or Produced IdenN/lcallon ---- P4 AFFIDAVIT OF ASSIGNMENT OF AGENT I .k�u42141) nx� Print Owner Name doing business as follows: X Individual Home Owner Entity: Print entity name Entity Tax ID#: Apt. Name: Owner tax id# I declare that I am the owner of the property located at: Unit address Cit ,state Zi. code I further state that I have authorized: Michael D. Newman State License #CVC56672 X Agent only Agent/Payee: 59-3269624 Agent Tax ID# 904-693-4555 mike.newman@energylabsinc.com Agent phone number Agent Email Address This authorization includes only the right to sign any and all papers necessary for acquiring permits for performing solar power installation work at the property located at the address above. My agent should be contacted with regard to any permitting requirements needed during the term of the solar project. This authorization shall remain in full force and effect for the duration of the solar power project associated with my address. This authorization shall expire within 30 days of all final inspections for permits pulled by my agent. ✓l diuird, e0K0 tef- Owner's Email Address 76,12/eta,--- 31z �o/I wner Signature Date NOTARIZED FORM SIGNED BEFORE ME, the undersigned authority, on this day I /ZI ?et<:y personally appeared known to me to be the person who has signed the foregoing document, and after being duly sworn, acknowledged to me that he/she had executed the same for the purposes and considerations therein expressed. SUBSCRIBED AND SWORN TO BEFORE ME THIS f;;l 1- DAY OF 41(11 20 1`t County of.. p,, Notary Signature: f' I MARK E.HOLLER 10)'State of. Florida Seal: NOTARY PUBLIC ` -STATE OF FLORIDA Cornm#GG039493 Expires 10/17/2020 Energy Laboratories, Inc. 1057 Ellis Road North, Jacksonville, Florida 32254 Solar Designs Mike Newman May 10,2019 Solar Energy Labs, Inc. 5191 Shawland Road Jacksonville, FL 32254 RE: Wind Load Certification: Boehme residence at 2434 Seminole Rd. Atlantic Beach FL Panasonic solar panels installed with IronRidge mounts and XR-100 rails Florida Building Code 2017 and ASCE7 compliance Dear Mike, The following factors were used in my calculations: I 1. Wind Speed= 130 mph, Risk Category=II 2. Wind Exposure=B or C Z<_ 30 ft. II Velocity Pressure: qz= .00256(1.16)(1)(.85) (.77)(130)2 =32.8 psf Force on collectors: F= .85(1.4)(32.8)=39.1 psf III Solar panels are certified to above 50 psf by the manufacturer. IV After careful review and analysis of the above system and the roof at the above address, I have determined that this system is capable of withstanding a 130 MPH wind loading and the added weight of 2.7 lbs./sq.ft. that the solar array will add to the roof. With this letter, I certify that the above PV system and the framing/roofing system of this location will be structurally adequate and will satisfy the FBC 2017 and ASCE7 for wind speeds up to 130 MPH. Digitally signed by Nelson Nelson Hellmuth •�`''='` n` `�C Hellmuth Date:2019.05.10 Sine: 1 4,4 7 15:23:50-04'00' ' , C, y' GC i Nels ;i. ' llr�tu4h I3' 14' `�l c,l/.f Flori ,dig1 8ec;7,1 15t 1738 Kingsley Ave. Orange Park, FL 32073 (904)269-8380 OFFICE COPY Solar Designs Mike Newman May 10,2019 Solar Energy Labs,Inc. 5191 Shawland Road Jacksonville, FL 32254 RE: Wind Load Certification: Boehme residence at 2434 Seminole Rd.Atlantic Beach FL Panasonic solar panels installed with IronRidge mounts and XR-100 rails Florida Building Code 2017 and ASCE7 compliance Dear Mike, The following factors were used in my calculations: I 1. Wind Speed= 130 mph, Risk Category =II 2. Wind Exposure=B or C Z<_ 30 ft. II Velocity Pressure: qz= .00256(1.16)(1) (.85) (.77X130) 2 = 32.8 psf Force on collectors: F= .85(1.4)(32.8)=39.1 psf III Solar panels are certified to above 50 psf by the manufacturer. IV After careful review and analysis of the above system and the roof at the above address, I have determined that this system is capable of withstanding a 130 MPH wind loading and the added weight of 2.7 lbs./sq.ft. that the solar array will add to the roof. With this letter, I certify that the above PV system and the framing/roofing system of this location will be structurally adequate and will satisfy the FBC 2017 and ASCE7 for wind speeds up to 130 MPH. Nelson Digitally signed by Nelson Hellmuth 0'F� sinc F 41.9 -1.7 1 , 4�IHellmuthDate:2019.05.10 15:23:50-04'00' `-.., • "") " ` r i� '' ' ,• ''• Nel obi 1738 Kingsley Ave. Orange Park, FL 32073 (904)269-8380 OFFICE COPY 8A irC sm 11111 01 §5 k R i 5 1 I k§ I A`'‘2 I mi2a I n.,tDsNSgyS Vp5p � J� p 80 g„,',, 1, --r'S ,k0 Z p,,; I D Z p ZNm m P< Smom I ?gmT m Q D D iL'';'-',V, I pIr T"'="9, s C ' i p ti v A Z 1� i F ri Zm 2 it iii! D 3:21 (y'� Z m m - .. o >�m m I r'A A° —_. i ID! z g -Di - II a a I I XX I a ys I Q I F.3 it I 25 p I M... 1 1 4111 P 1 a K N 1 Z I 1 S 4 I I II 'II' 1 P° c,I q gm gm SAE THE THOUGHTS ANO DEASREVISION DATE BY CND BOEHME Residence EXPRESSED HERE WYHN Solar Ene3rgy labs SCALE. NTS A1C( Y%% XXX X%% 5 - g x 2434 North Seminole Road, SOLAR A:ELr'E DIE AC,usr,T PROPERTY 6 EPEBSY DATE OL0&19 Atlantic Beach, Florida E LABS.ND TME USE oP 1057 Bits Road North#17 a 2 ENERGY LABS THESE PROTECTS JACKSONVILLE,E,FLORIDA 32254 DRAWN CPR WITHOUT THE WRITTEN BY PV Array Field Wiring Diagram CONSENT Of ENERGY LASS 19041693-4555 APPROVED NN OCOPVAWOR AE ENERGY LABORATORIES NC. INC..IS NOT PERALTTED 9Y OFFICE COPY Enphase AC Combiner Box En p hase AC Combiner Box . _ ,..- _ ,,,,-,,-.,...i!,*.,6:„."-::-.lit,r,'-- 0 , , ,. . . . . . e enphase 1I 1 "---"' ., t. ; M< 41 0111; '- Y1!I. L.nii i . i iP / ,• \, The Enphase \C Combiner Box with Envoy-S consolidates interconnection equipment into a single enclosure and streamlines PV installations by providing a consistent, pre-wired solution for residential applications. SMART SIMPLE RELIABLE - Includes Envoy-S for communication - Three pre-installed 20 A/240 VAC - Durable NRTL-certified NEMA type and control circuit breakers 3R enclosure - Flexible networking supports Wi-Fi, - Pre-configured revenue-grade - Five-year warranty Ethernet,or cellular metering available 43 eENPHAsE LISTED OFFICE COPY Enphase AC Combiner Box II DATA MODEL NUMBER AC Combiner Box XAM1-120 AC combiner with Enphase Envoy-S Metered'for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%,pending)and optional consumption monitoring(+/-2.5%). ACCESSORIES(Order Separately) Enphase Mobile Connect' Plug and play industrial grade cellular modem with five-year data plan for systems up to 60 CELLMODEM-01 microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, where there is adequate cellular service in the installation area.) Consumption Monitoring CT Split core current transformers enable whole home consumption metering(+/-2.5%). CT-200-SPLIT ELECTRICAL SPECIFICATIONS Maximum system size 11.5 kW at 240 VAC Rating Continuous duty Maximum system voltage 240 VAC Rated output current 48 A Rated input current,each input 16 A Maximum fuse/circuit breaker rating(output) 60 A Solar branch circuit breakers Three 2-pole 20A/240 VAC DIN rail-mounted breakers Production Metering CT 200A solid core pre-installed on solar busbar and wired to Envoy-S MECHANICAL DATA Dimensions(WxHxD) 38.0 x 38.7 x 20.3 cm(15.0"x 15.3"x 8.0") Weight 5.1 kg(11.2 lbs) Ambient temperature range -40°C to+46°C(-40°to 115°F) Cooling Vented,natural convection Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire size 10 AWG for branch inputs 4 AWG for combined output(3 circuits) 6 AWG for combined output(2 circuits) Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Cellular Optional,CELLMODEM-01 (not included) COMPLIANCE Compliance,Combiner Box UL 1741 Compliance,Envoy-S UL 916 CAN/CSA C22.2 No.61010-1 47 CFR,Part 15,Class B,ICES 003 IEC/EN 61010-1:2010, EN50065-1,EN61000-4-5,EN61000-6-1,EN61000-6-2 Metering:ANSI C12.20 accuracy class 0.5 To learn more about Enphase Microinverter technology, E N P H AS E., visit enphase.com u ©2016 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. February 2016 OFFICE V AFFIDAVIT OF ASSIGNMENT OF AGENT 121cuAQb • Print Owner Name doing business as follows: X Individual Home Owner Entity: Print entity name Entity Tax ID#: Apt. Name: Owner tax id# I declare that I am the owner of the property located at: Unit address Ci ,state Zi.code I further state that I have authorized: Michael D. Newman State License #CVC56672 X Agent only Agent/Payee: 59-3269624 Agent Tax ID# 904-693-4555 mike.newman a©energylabsinc.com Agent phone number Agent Email Address This authorization includes only the right to sign any and all papers necessary for acquiring permits for performing solar power installation work at the property located at the address above. My agent should be contacted with regard to any permitting requirements needed during the term of the solar project. This authorization shall remain in full force and effect for the duration of the solar power project associated with my address. This authorization shall expire within 30 days of all final inspections for permits pulled by my agent. ►'1 6L bcelyx etiev •- in5Ai Joie., bet / Owner's Email Address ✓/�l . — 3/Z-4 ZW? Owner Signature Date NOTARIZED FORM SIGNED BEFORE ME, the undersigned authority, on this day jy: , / /2-i z e l y personally appeared known to me to be the person who has signed the foregoing document, and after being duly sworn, acknowledged to me that he/she had executed the same for the purposes and considerations therein expressed. SUBSCRIBED AND SWORN TO BEFORE ME THIS 11 Ir, DAY OF 4(r,1 20 1`1 County of. 77,,v« Notary Signature: 4.4 MARK E.HOLLER Florida NOTARY PUBLIC State of Seal: • ; STATE OF FLORIDA Comm#GG039493 ' Expires 10/17/2020 Energy Laboratories. Inc. 1057 Ellis Road North. Jacksonville. Florida 32254 OFFICE COPY Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7X Micro' dramatically simplifies the IQ 7X M icroinverter installation process while achieving the highest system efficiency for systems with 96-cell modules. Part of the Enphase IQ System,the IQ 7X Micro integrates with the Enphase IQ Envoy'", Enphase IQ BatteryCTM,and the Enphase Enlighten'" monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install ' • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) I Efficient and Reliable • Optimized for high powered 96-cell*modules • Highest CEC efficiency of 97.5% • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7X Is required to support 96-cell modules. CERTIFIED WM'usCA E341165 ENPHASE. E. To learn more about Enphase offerings,visit enphase.com a OFFICE COPY Enphase IQ 7X Microinverter INPUT DATA(DC) IQ7X-96-2-US and IQ7X-96-B-US Commonly used module pairings' 320 W-460 W+ Module compatibility 96-cell PV modules Maximum input DC voltage 80 V Peak power tracking voltage 53 V-64 V Operating range 25 V-80 V Min/Max start voltage 30 V/80 V Max DC short circuit current(module Ise) 10 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) Peak output power 320 VA Maximum continuous output power 315 VA Nominal(L-L)voltage/range2 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 1.31 A(240 VAC) 1.51 A(208 VAC) Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 12(240 VAC) 10(208 VAC) Overvoltage class AC port III AC port backfeed current 0 A Power factor setting 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V CEC weighted efficiency 97.5% 96.5% MECHANICAL DATA Ambient temperature range -40°C to+60°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7X-96-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7X-96-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 -PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator athttps://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com a EN PHAS E. c)2018 Enphase Energy.All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc 2018-05-24 OFFILt GUr HIT Panasonic Photovoltaic Module N330/N325 1 ELECTRICAL SPECIFICATIONS l PERFORMANCE WARRANTY A VBHN330SA16 VBHN325SA16 len ' MI I Rated Power IPmaxl' 330W 325W rete i Maximum Power Voltage IVpml 58.0V 57.6V xtea res Maximum Power Current IIpml 5.70A 5.65A wee... Open Circuit Voltage(Von( 69.7V 69.6V say. ewrxgene • Short Circuit Current Ilscl 6.07A 6.03A ws SW Temperature Coefficient IPmaxI -0.258%/°C -0.258%/°C 7. Temperature Coefficient IVocl -0.16V/°C -0.16V/°C Temperature Coefficient hscl SII 3.34mA/°C 3.32mA/°C e s vu Is to a NOCT 44.0°C 44.0°C wlettemmic •Cera et. I CEC PTC Rating 311.3W 306.5W Cell Efficiency 22.09% 21.76% DIMENSIONS IT Module Efficiency 19.7% 19.4% I it810531 1.335 =MB = 0'IF -75 Watts per Ft? 18.3W 18.0W 1 __-- r --- • Maximum System Voltage 600V 600V I■■■■■■■■I i' \ ♦r 3 Series Fuse Rating 15A 15A ■■■■■■■■ r -Ifo ,407 i Warranted Tolerance I-/+I +10%/-0%• +109L/-0%• i A 1,111.11,11,B1111111,111.11,11,B111111 '4 .■.■■..■ p MECHANICAL SPECIFICATI�N� - ■. I.MES. ■. VBHN3305A16,VBHN3255A76 .■■■■■■■ e ®' Internal Bypass Diodes 4 Bypass Diodes .■■■■U�■ Module Area 18.02 Ft.'(1.67m'I ',.......■ 39.71tne ' Weight • 40.81 Lbs.118.5kg1I g Q Dimensions LxWxH 62.6x41.5xt.4 in.11590x1053x35 mml 'i.■■■-■.■1 I Cable Length+Male/-Female 40.2/40.2 in.11020/1020 mml _ • Cable Size/Type No.12 AWG/PV Cable A 171 Connector Type' Multi-Contact.Type IV IMC4Tel g w °? 1U 5990252N Static Wind/Snow Load - H am12o�IL4 o 50 PSF 12400 Pal Pallet Dimensions LxWxH 63.7x42.2x65.4 in, L 12601321 I i I f 4571371 Quantity per Pallet/Pallet Weight 1 40 pcs./1719 Lbs.1780 kgl Unit:inches Imml Section A-A' Section B-13.Quantity per 40'Container 560 pcs. \ J Quantity per 20'Container 1 240 pcs. DEPENDENCE ON IRRADIANCE \ - 7.00 ( \ t000wnd OPERATING CONDITIONS&SAFETY RATIN(," 8.00 6HN330SA16.VBHN325SA16 5.00 0041/n1 - - Q Operating Temperature -40°F to 185°F 1-40°C to 85°CI � 4.00 woW/ni m Hail Safety Impact Velocity 1'hailstone 125mm1 at 52 mph 123m/s1 co 3.00 a00W/rd Safety&Rating Certifications UL 1703.cUL.CEC _ UL 1703 Fire Classification Type 2 2.00 20DW/rd Limited Warranty 25"Yrs Workmanship and Power Output'Lineal-I"' 1.00 - - 0.00 NOTE:Standard Test Conditions:Air mass 1.5;irradiance=1000W/m°;cell temp.25°C 0 10 20 30 40 50 e0 70 80 •Maximum power at delivery.For guarantee conditions,please check our guarantee document. Voltage(VI "Installation need to be registered through our website wwwatrantx.cem within 60 days Reference data for model:VBHN3305A16 w.� in order to receive twenty-five 1251 year Product workmanship Otherwise.Product Workmanship will be Well temperature:25°CI only fifteen 1151 years. ---- "81st year 97%,after 2nd year 0.26%annual degradation to year 25. &CAUTION!Please read the installation manual carefully before using the products. 'STC:Cell temp.25°C.AM1.5,1000W/m° Used electrical and electronic products must not be mixed with general household waste.For proper treatment, ,Safety locking clip IPV-SSH4I is not supplied with the module. recovery and recycling of old products,please take them to applicable collection points in accordance with NOTE:Specifications and information above may change without notice. your national legislation. Panasonic Eco Solutions of North America All Rights Reserved 02017 COPYRIGHT Panasonic Corporation Two Riverfront Plaza,5th Floor,Newark,NJ 07102 Specifications are subject to change without notice Panasonic panasonicHlT@us.panasonic.com 04/2017 business.panasonic.com/solarpanets RS17170_OS OFFICE COPY HIT Panasonic Photovoltaic Module N330/N325 Panasonic's unique heterojunction technology uses ultra-thin amorphous silicon layers.These thin dual layers reduce losses, — resulting in higher energy output than conventional panels. ..r=_'� likill. ah � u wIIII � 110011110101111111l ooIIIIIIIIIIII . .. .o-,Yw<VO,O.».ir<oh..sa.�M.aw�k. o ' 11101101111111111111morphoto...MOO.ewerI Tr sparamelectrodeITCCIm Eiiii �ak�.�Y�.K�.a.. I E4cVOMa Advanced bifacial cell designed for increased energy output. 1jIffh1IIIhffh!II Ii The cell utilizes sunlight reflected back from the rear side 1111111Mmaterial which captures more light and converted into energy. ili Panasonic a... u.. III , 1I Illlaim mini ll flack Sheri B.lck Sheet Our competitive advantages ,‘ .,4High Efficiency at High Temperatures 25 Year Product and Performance Warranty** increases, ® leading yeoduct workmanship � As performtemperature at high levels due to HITthe industrycontinues leadingto and performanceIndustry25 warrantyarpris backed by a century temperature coefficient of-0.258%/°C. No other old company- Panasonic. Power output is module even comes close to our temperature guaranteed to 90.76%after 25 years,far greater characteristics. That means more energy than other companies. throughout the day. 0 %j'Quality and Reliability Higher Efficiency 19.7% Panasonic's vertical integration,20 years of �', Enables higher power output and greater energy W experience manufacturing HIT®and 20 internal yields. HIT®provides maximum production for your tests beyond those mandated by current limited roof space. standards provides extreme quality assurance. COD Low Degradation Unique water drainage ` ` clopHIT"N-type" cells result in extremely Low Light !//.J The water drainage system give rain,water and Induced Degradation (LID) and zero Potential _ snow melt a place to go,reducing water stains and Induced Degradation (PID)which supports soiling on the panel. Less dirt on the panel means reliability and longevity.This technology reduces more sunlight getting through to generate power. annual degradation to 0.26%compare to 0.70% in conventional panels,guaranteeing more power for the long haul. HIT•is a registered trademark of Panasonic Group OFFICE COPY Intertek AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: IronRidge, Inc. 1495 Zephyr Ave 1435 Baechtel Road Address: Hayward, CA 94544 Address: Willits, CA 95490 Country: USA Country: USA Contact: Yann Schwarz Contact: Jim Norsworthy Phone: (800)227-9523 Phone: (800)227-9523 FAX: (707)459-1833 FAX: (707)459-1833 Email: yschwarz@ironridge.com Email: jnorsworthy@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CAC_Okcj-61/4.A9._. 5�QIC Control Number: 4007559 Authorized by: for Thomas J. Patterson, Certification Manager Ell.CLASSIFIED ruS o Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any partyother than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.initial Factory Assessments and Follow up Services are for the purpose of assuring appropnate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat-Plate Standard(s): Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: IronRidge Roof Mount Models: XR Rails ATM for Report 101541132LAX-002 Page 1 of 3 ATM Issued: 24-Apr-2015 ED 16.3.15(1-Jan-13)Mandatory nPPIrl= r°,11 0.4v Intertek AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: IronRidge, Inc. 1495 Zephyr Ave 1495 Zephyr Ave Address: Hayward, CA 94544 Address: Hayward, CA 94544 Country: USA Country: USA Contact: Yann Schwarz Contact: Jim Norsworthy Or Dave Taggart Phone: (800)227-9523 Phone: (707)363-3025 FAX: (707)459-1833 FAX: (510)225-0975 Email: yschwarz@ironridge.com Email: jnorsworthy@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA / . # Control Number: 40.08377 Authorized by: for Thomas J. Patterson, Certification Manager ETL CLASSIFIED (CPUS Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any partyother than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material.product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat-Plate Standard(s): Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: Iron Ridge Roof Mount Models: XR Rails ATM for Report 101541132LAX-002 Page 2 of 3 ATM Issued: 24-Apr-2015 ED 16.3.15(1-Jan-13)Mandatory OFFICE COP s Intertek AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: Precision Die&Stamping, Inc. 1495 Zephyr Ave 1704 W. 10th Street Address: Address: Hayward, CA 94544 Tempe, AZ 85281 Country: USA Country: USA Contact: Yann Schwarz Contact: Andy Frola Phone: (800)227-9523 Phone: (480)967-2038 FAX: (707)459-1833 FAX: (480)829-0838 Email: yschwarz@ironridge.com Email: andy@precisiondie.com Party Authorized To Apply Mark: Same as Manufacturer jjz}J\9_. pmReport Issuing Office: Lake Forest, CA 92 ` Control Number: 4008083 Authorized by: for Thomas J. Patterson, Certification Manager ETL CLASSIFIED CD Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any partyother than to the Client in accordance with the agreement.for any lossexpense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested matenal.product or service must first be approved in writing by Intertek Initial Factory Assessments and Follow up Services are for the purpose of assuring appropnate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat-Plate Standard(s). Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: IronRidge Roof Mount Models: XR Rails ATM for Report 101541132LAX-002 Page 3 of 3 ATM Issued: 24-Apr-2015 ED 16 3.15(1-Jan-13)Mandatory OFFICE Ca- f Tech Brief // IRONRIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless '---..,,,, ,, extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing f ,,,,....,,,, -- r 1 enough to buckle a panel frame. XR Rails are the structural backbone preventing it .„ 7- ,,..t.....,4 these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. - Their superior spanning capability4110 requires fewer roof attachments, reducing the number of roof !...,% penetrations and the amount of installation time. •• ti a`�w / / ' Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them iiyi to bend and twist.The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat& Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of marine-grade compatible with a range of tilt leg aluminum alloy,then protected with an roN FlashFoot and options for flat anodized finish.Anodizing prevents surface111 1 J other pitched roof root mounting and structural corrosion,while also providing attachmentsapplicationsa more attractive appearance. -111 OFFICE COP= � Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail. It supports a range of solar mounting rails. It's built to handle no snow. It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or remaining light and economical. maximizing spans up to 8 feet. more for commercial applications. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Rail Span Snow (PSF) Wind (MPH) 4' 5'4" 6' 1111311111._ 10' 12' 100 120 None 140 XR10 XR100 XR1000 160 100 120 10-20 140 160 100 30 160 100 40 160 50-70 160 80-90 160 60 2014 IronRidge,Inc.All nghts reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.12 /��_ OFFICE COPY S-5-6 Top 2,617gc) I O M8-1.25 Threaded Holelilt _ • =sEi:1-.: ler .53in 94in _i_ NhAz Scale 2:1 �- .24in•-- .50in Back Left Front Right i (2x) 3/8-24 Threaded Hole l.00inW ' lijii ; ; 25in OF --1 1.00inH 1.89in �.38inj F+ 25in 1.64in 2 FOR STANDING SEAM SPECIFIC MECHANICAL LOAD TEST ic— INFORMATION AND CLAMP INSTALLATION INFORMATION PLEASE VISIT:WWW.S-5.COM 1 «YdYI ILI INN BRASS METAL W T BU WITT VD LTD. SW WEN... C 11: COLORADO SPRINGS.Co 110906 General Notes: �3 0512 rneFtight w.y! "°3-°m'° )19-10590051E 1.S-S-B Clamp 4 "PP`n � 2.M8-1.25 Stainless Steel Hex Flange Bolt(13mm Socket) J """ �"�" , s S-B 3.3/8-24 Stainless Steel Round Point Setscrew(3/16 Hex Drive) ,�E - °OSA �- add°' �'"'"D16 4.Example roof SelAcnn.r.0.011:0 be :°.0 LMOREZIGOIMINTS ��.........:,a,acraDierl R.0.o-..,o,AND..o.R., bR:GAO/5b OFFICE COPY . c,c, s_5! 04-• The right wayTM to attach almost anything to metal roofs! Cl) C The Right Way!TM '� Installation Instructions o6 S-51°Warning!Please use these products responsibly!Visit our website or contact your S-5!distributor for available load test results.The user and/or installer of these At parts is responsible for all necessary engineering and design to ensure the 5-5!clamps e have been properly spaced and configured.Notice to S-51 users:Due to the many variables involved with specific panel products,climates,snow melt phenomena,and Cl)dii ., job particulars,the manufacturer cannot and does not express any opinions as to the C suitability of any S-5!assembly for any specific application and assumes no liability with respect thereto.5-5!products are tested for ultimate holding strength on various W profile types and materials.Visit www.5-5.com for more details.This document is an installation guide only and the photographs and drawings herein are for the purpose21111P7 Ln of illustrating installation,tools and techniques,not system designs.Information f��� contained within is intended to apply to the document as a whole. V! The 5-5-U,S-5-S,S-5-E,S-5-B,and 5-5-V clamps are made for standing seam profiles.For horizontal seam applications,the setscrew(s)must be accessible W from the top for tightening.S-5-U clamps have two bolt holes to accommodate . kali LO either vertical or horizontal seam applications;visit www.S-5.com for more details. WI Tools Needed 3 .. • Screw Gun* `:: Cn • 3/16"Allen Bit Tip(provided) • Dial-Calibrated Torque Wrench Ln (For accurate tension values,do NOT use a clicking torque wrench;inquire with S-5!for proper tool sourcing) To Install the S-5-U, S-5-S, S-5-E, S-5-B, and S-5-V Ln 1. Partially thread the setscrews into the clamp by hand.(The S-5-U has four setscrew Cn locations to make the clamp more versatile;however,only two setscrews are used per 1111 clamp.Both setscrews should always be loaded into the same side of the clamp.) 2. Determine how to position the clamp.When attaching to machine-folded seams (regardless of panel profile and geometry),S-5!clamps are designed to engage the E seam as shown in Illustration A;with setscrew opposite seam fold.On many snap- , together type seams,the setscrews are on the open(or overlap)side of the seam.On 1 - . o some seams,this aspect of clamp orientation is not critical. Above illustrations show S-5-U clamp C) on a vertical seam.Step 2 shows both in 3. Tighten the setscrews using a screw gun*and the included screw gun bit tip. vertical and horizontal applications. Setscrews should be tensioned and re-tensioned as the seam material compresses,i.e. tighten the first setscrew,then the second;then repeat until each setscrew achieves Illustration A the recommended torque.The setscrews will dimple the seam material but will not E(J-L.)31- penetrate it.When relying on published load values,setscrew tension should be - rn. >_ 0.65" verified periodically using a calibrated torque wrench as indicated below to ensure the _, k, 5 tool is consistently achieving the proper torque range. Note: See"Step 3 Note"at bottom of document on fitting S-5-U and S-5-V on certain vertical double-folds. For time-saving tool recommendations,call S-5! N E.`1 ch Specified Torque Inch Pounds Foot Pounds Nm t 22gasteel 160-180 13-15 18-20 ` to M • All other metals and I t thinner gauges of steel 130-150 11-12.5 15-17 (Top)S-S-U clamp on both vertical and horizontal seams. N Once installed correctly,these clamps require no maintenance or re- (Bottom)5-5-Son a snap together seam with blow up CO inspection for the life of the roof. illustrating deformation of seam as setscrew is tightened CO For horizontal seams equal to or greater than.65"use the W 4. For critical attachment applications utilizing an M8-1.25 X 16 mm Hex Flange S-S-U in Its horizontal orientation. CO Bolt,tighten the included M8 bolt to 160 inch pounds(13 foot pounds). For horizontal seams equal to or less than.50"use the S-5-S M mounted vertically. co These instructions are for use by those experienced in the trade.Always follow appropriate safety precautions and use appropriate tools. • FFI E r • “ S-5-U Mini, S-5-S Mini, S-5-E Mini, S-5-B Mini, and S-5-V Mini Installation Instructions To Install the S-5-U Mini, S-5-S Mini, S-5-E Mini, S-5-B Mini, and S-5-V Mini 1. Partially thread the setscrew into the clamp by hand. 2. Determine how to position the clamp.When attaching to machine-folded seams (regardless of panel profile and geometry),S-5!®clamps are designed to engage the seam as shown in Illustration A on the front page;with setscrew opposite seam fold.On many snap-together type seams,the setscrew is on the open(or overlap)side of the seam.On some seams,this aspect of clamp orientation is not critical. 3. Tighten the setscrew using a screw gun*and the included screw gun bit tip. The setscrew will dimple the seam material but will not penetrate it.When relying on published load values, setscrew tension should be verified periodically using a calibrated torque wrench as indicated below to ensure the tool is consistently achieving the proper torque range. Note: See "Step 3 Note"at bottom of document on fitting S-S-U Mini and S-5-V Mini on certain vertical double-folds. 3 `For time-saving tool recommendations,call 5-5! Specified Torque Inch Pounds Foot Pounds Nm 22ga steel 160-180 13-15 18-20 All other metals and 130-150 11-12.5 15-17 thinner gauges of steel Once installed correctly,these clamps require no maintenance or re- , 4 inspection for the life of the roof. 4. For critical attachment applications utilizing an M8-1.25 X 16 mm Hex Flange Bolt,tighten the included M8 bolt to 160 inch pounds(13 foot pounds). Step 3 Note: When installing S-5-U,S-5-V,S-S-U Mini,or S-S-V Mini on 4 a vertical double fold,you may need to lift clamp in a manner that allows the lip of the clamp to engage the bottom of the seam and the setscrew(s)to fully engage the fold while tightening the setscrew(s). See clamp lip engagement in figure below. This will assist in making the clamp sit more vertically on the seam. Above illustrations show S-5-E Mini clamp on a vertical seam.Step 2 shows S-5-E Mini on vertical applications and S-5-U Mini on { horizontal applications. S-5!e Warning!Please use this product responsibly! Products are protected by multiple U.S.and foreign patents.Visit the website at www.S-5.com for complete information on patents and trademarks.For maximum holding strength, setscrews should be tensioned and re-tensioned as the seam material compresses,i.e.tighten the first setscrew,then the second;then repeat until each setscrew achieves the recommended torque.Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel,and between 130 and 150 inch pounds for all other metals and thinner gauges of steel.Consult the 5-51 website at www.5-5.com for published data regarding holding strength. Copyright 2019,Metal Roof Innovations,Ltd.5-5!products are patent protected. S-51 aggressively protects its patents,trademarks,and copyrights.Version 012919. USEBVI-V1.1-0119 /`i '" IRONRIDGE UFO Family of Components Simplified Grounding for Every Application The UFO family of components eliminates the need for Ammar,— separate grounding hardware by bonding solar modules AIMINIMINNN 1101111. Nmius =M. directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. 3 Nulff=mv OUP -"m111111=1111111110w- Stopper Sleeve Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR iiiiiihop onto the UFO,converting it into Rails. It comes assembled and lubricated,and a a bonded end clamp. can fit a wide range of module heights. /. . . . . . - . --.c :. / �9F • /. . , / x i . Bonded Splice '' 4 Each Bonded Splice uses \ y — — ,,)::L self-drilling screws to form a secure connection. No FNn bonding strap needed. Grounding Lug mooo A single Grounding Lug Bonded Attachments �� connects an entire row The bonding bolt attaches of PV modules to the and bonds the L-foot to the 1. grounding conductor. rail. It is installed with the �1 same socket as the rest of the 1 system. OFFICECOPY Tech Brief System Diagram _. O 0- - - I - - -0 a_ _• 0 - - - - - -0 0 0- =