Loading...
369 10th St ROOF20-0036 Metal RoofOWNER:ADDRESS:CITY:STATE:ZIP: AYERS JOSEPH A & AMY L 369 10TH ST ATLANTIC BEACH FL 32233-5529 COMPANY:ADDRESS:CITY:STATE:ZIP: TOWNSEND ROOFING & CONSTRUCTIONS SERVICE 10418 New Berlin Rd #115 JACKSONVILLE FL 32226 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170086 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 369 10TH ST ROOF NON SHINGLE METAL ROOF $10000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $161.86 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 6/29/2020 PERMIT NUMBER ROOF20-0036 ISSUED: 6/29/2020 EXPIRES: 12/26/2020 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 6/29/2020 PERMIT NUMBER ROOF20-0036 ISSUED: 6/29/2020 EXPIRES: 12/26/2020 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $161.86 ROOF20-0036 Address: 369 10TH ST APN: 170086 0000 $161.86 BUILDING $105.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN REVIEW $52.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE SURCHARGES $4.36 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R12193 $161.86 Printed: Monday, June 29, 2020 4:31 PM Date Paid: Monday, June 29, 2020 Paid By: TOWNSEND ROOFING & CONSTRUCTIONS SERVICE Pay Method: CHECK 9930 1 of 1 Cashier: LE Cash Register Receipt City of Atlantic Beach Receipt Number R12193 Revision Request/Correction to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 ··AlL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Phone: (904) 247-5826 Email: Bui lding-Dept@coab.us PERMIT #; ROOF20-0036 o Revision to Issued Permit OR o Corrections to Comments Date:06f09/2020 Project Address: ::3~69:...:.'~OT:.:H..:.::S~T ________________________________ _ Contractor/Contact Name: Townsend Roofing and Construction Services, Inc. I Chris Townsend Contact Phone: ,(:.90:.4,,).:.4.:.7,,2-4.:..:.47,,9'---________ Email: chris@townsendroofing.com Description of Proposed Revision / Corrections: I'm uploading metal roof instructions and evaluation report to your FTP site Underlayment is Polyglass Polystick TU-Max FL52S9 .1 I ,_ '-__ ---'_~_-__ -__ ~-"~_'-_____ affirm the revision/correction to comments is inclusive of the proposed changes . (printed name) • Will proposed revision/corrections add additional square footage to original submittal? EJNo D Yes (additional s.f. to be added: ) .~ill propose~ revision~c.orrec~ions ad~ add~ti~nal increase in building value to original submittal? ~No DYes (additional Increase In bUilding value: $ A ) {Contractor must sign if increase in valuation) *Signature of Contractor/Agent: ~ 2Z. (Office Use Only) D Approved o Denied o Not Applicable to Department Pennit Fee Due $, _____ _ Revision/Plan Review Comments' _______________________________ _ Department Review Required: Building Planning & Zoning Tr ee Administrator Public Works Public Utilities Public Safety Fire Services Reviewed By Date Updated 10/17/18 © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 1 RESIDENTIAL DESIGN GUIDE SAFETY STUDY APPLICABLE OSHA AND OTHER SAFETY REQUIREMENTS BEFORE FOLLOWING THESE INSTRUCTIONS. The installation of metal roof systems is a dangerous procedure and should be supervised by trained knowledgeable erectors. USE EXTREME CARE WHILE INSTALLING ROOF PANELS. It is not possible for Metal Sales to be aware of all the possible job site situations that could cause an unsafe condition to exist. The erector of the roof system is responsible for reading these instructions and determining the safest way to install the roof system. These instructions are provided only as a guide to show a knowledgeable, trained erector the correct relationship of parts to one another. If following any of the installation steps would endanger a worker, the erector should stop work and decide upon a corrective action. Provide required safety railing, netting, or safety lines for crew members working on the roof. Do not use the roof panel as a walking platform. The roof panels will not withstand the weight of a person standing at the edge of the panel. Do not stand on any roof panels until the panels have been attached. The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects should conform to applicable building codes for that particular area. It is recommended to follow all building regulations and standard industry practices. Metal Sales Manufacturing Corporation is not responsible for the performance of the roof system if it is not installed in accordance with the suggested instructions referenced in this manual. If there is a conflict between this manual and the actual erection drawings, the erection drawings are to take precedence. Prior to ordering and installing materials, all dimensions should be verified by field measurements. Metal Sales reserves the right to modify, without notice, any details, recommendations or suggestions. Any questions you may have regarding proper installation of these Residential roofing systems should be directed to your local Metal Sales representative, (see pages 2 and 3). Oil canning is not a cause for rejection. Oil canning can be described as the amount of waviness found in the flat areas of metal panels. Oil canning is an inherent characteristic of light gauge cold formed metal products, particularly those with broad flat areas. There are many factors which may contribute to oil canning that Metal Sales is not able to control. These factors include: misalignment of the support system, over driving of fasteners used on the panels, stress (whether inherent in the panel or induced), thermal expansion and contraction of the panel, improper material handling, width, gauge, length, color of panels, and improper installation (reference Metal Construction Association "Oil Canning Position Paper"- Appendix A). Consult your local Metal Sales Branch for any additional information not outlined in this manual. This manual is designed to be utilized as a guide when installing a Residential roofing system. It is the responsibility of the erector to ensure the safe installation of this product system. Important Information © Metal Sales Manufacturing Corporation / Subject to change without notice 4/172 RESIDENTIAL DESIGN GUIDE 15 14 5,101 9 8 13 4 11 18 6 17 3 12 7 19 2 16 20 21 Branch Territory Map Important Information .........................................1 Branch Territory Map ..........................................2 Branch Locations ................................................3 Vertical Seam Panel Options ..............................4 Vertical Seam Design Information .......................5 Image II Panel Options .......................................6 Image II Design Information ................................7 Flashing Profiles ............................................8-12 Accessories .......................................................13 Tools .................................................................14 Fasteners ..........................................................15 VERTICAL SEAM DETAILS Eave ..................................................................16 Extended Eave ..................................................17 W-Valley ...........................................................18 Residential Rake ...............................................19 Rakewall with Counter .......................................20 Rakewall with Counter and Receiver.................21 Rakewall ............................................................22 Ridge/Hip ...........................................................23 Ridge/Hip Notch Detail ......................................24 Hip End Cap Detail ............................................25 Pitch Break ........................................................26 Vented Peak .....................................................27 Peak ..................................................................28 Peak Flashing Lap Details ................................29 IMAGE II DETAILS Eave ..................................................................30 Extended Eave ..................................................31 W-Valley ...........................................................32 Residential Rake ...............................................33 Rakewall with Counter .......................................34 Rakewall with Counter and Receiver.................35 Rakewall ............................................................36 Ridge/Hip ...........................................................37 Ridge/Hip Notch Detail ......................................38 Hip End Cap Detail ............................................39 Pitch Break ........................................................40 Vented Peak .....................................................41 Peak ..................................................................42 Peak Flashing Lap Details ................................43 Skylight/Chimney Details ..............................44-45 Care and Maintenance ......................................46 Notes .........................................................47-48 TABLE OF CONTENTS NOTE: Shaded areas represent regions served by each location. * © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 3 RESIDENTIAL DESIGN GUIDE 1.) DENVER BRANCH 7990 East I-25 Frontage Road Longmont, CO 80504 303.702.5440 Phone 800.289.7663 Toll Free 800.289.1617 Toll Free Fax 2.) JACKSONVILLE BRANCH 7110 Stuart Avenue Jacksonville, FL 32254 904.783.3660 Phone 800.394.4419 Toll Free 904.783.9175 Fax 800.413.3292 Toll Free Fax 3.) JEFFERSON BRANCH 352 East Erie Street Jefferson, OH 44047 440.576.9070 Phone 800.321.5833 Toll Free 440.576.9242 Fax 800.233.5719 Toll Free Fax 4.) INDEPENDENCE BRANCH 1306 South Powell Road Independence, MO 64057 816.796.0900 Phone 800.747.0012 Toll Free 816.796.0906 Fax 5.) SELLERSBURG BRANCH 7800 State Road 60 Sellersburg, IN 47172 812.246.1866 Phone 800.999.7777 Toll Free 812.246.0893 Fax 800.477.9318 Toll Free Fax 6.) ROGERS BRANCH 22651 Industrial Boulevard Rogers, MN 55374 763.428.8080 Phone 800.328.9316 Toll Free 763.428.8525 Fax 800.938.9119 Toll Free Fax 7.) NASHVILLE BRANCH 4314 Hurricane Creek Boulevard Antioch, TN 37013 615.641.7100 Phone 800.251.8508 Toll Free 615.641.7118 Fax 800.419.4372 Toll Free Fax 8.) SPOKANE BRANCH 2727 East Trent Avenue Spokane, WA 99202 509.536.6000 Phone 800.572.6565 Toll Free 509.534.4427 Fax 9.) SEATTLE BRANCH 20213 84th Avenue, South Kent, WA 98032 253.872.5750 Phone 800.431.3470 Toll Free (Outside WA) 800.742.7900 Toll Free (Inside WA) 253.872.2008 Fax 10.) NEW ALBANY BRANCH 999 Park Place New Albany, IN 47150 812.944.2733 Phone 812.944.1418 Fax 11.) ROCK ISLAND BRANCH 8111 West 29th Street Rock Island, IL 61201 309.787.1200 Phone 800.747.1206 Toll Free 309.787.1833 Fax 12.) DEER LAKE BRANCH 29 Pinedale Industrial Road Orwigsburg, PA 17961 570.366.2020 Phone 800.544.2577 Toll Free 570.366.1648 Fax 800.544.2574 Toll Free Fax 13.) TEMPLE BRANCH 3838 North General Bruce Drive Temple, TX 76501 254.791.6650 Phone 800.543.4415 Toll Free 254.791.6655 Fax 800.543.4473 Toll Free Fax 14.) WOODLAND BRANCH 1326 Paddock Place Woodland, CA 95776 530.668.5690 Phone 800.759.6019 Toll Free 530.668.0901 Fax 15.) FONTANA BRANCH 14213 Whittram Avenue Fontana, CA 92335 909.829.8618 Phone 800.782.7953 Toll Free 909.829.9083 Fax 16.) ANCHORAGE BRANCH 4637 Old Seward Highway Anchorage, AK 99503 907.646.7663 Phone 866.640.7663 Toll Free 907.646.7664 Fax 17.) BAY CITY BRANCH 5209 Mackinaw Road Bay City, MI 48706 989.686.5879 Phone 888.777.7640 Toll Free 989.686.5870 Fax 888.777.0112 Toll Free Fax 18.) DETROIT LAKES BRANCH 1435 Egret Avenue Detroit Lakes, MN 56501 218.847.2988 Phone 888.594.1394 Toll Free 218.847.4835 Fax 888.594.1454 Toll Free Fax 19.) MOCKSVILLE BRANCH 188 Quality Drive Mocksville, NC 27028 336.751.6381 Phone 800.228.6119 Toll Free 336.751.6301 Fax 800.228.7916 Toll Free Fax 20.) FORT SMITH BRANCH 7510 Ball Road Fort Smith, AR 72908 479.646.1176 Phone 877.452.3915 Toll Free 479.646.5204 Fax 21.) SIOUX FALLS BRANCH 2700 West 3rd Street, Suite 4 Sioux Falls, SD 57104 605.335.2745 Phone 888.299.0024 Toll Free TECHNICAL SERVICES 545 South 3rd Street, Suite 200 Louisville, KY 40202 502.855.4300 Phone 800.406.7387 Toll Free 502.855.4290 Fax 800.944.6884 Toll Free Fax TECHNICAL SUPPORT Branch Locations © Metal Sales Manufacturing Corporation / Subject to change without notice 4/174 RESIDENTIAL DESIGN GUIDE Product No.Coverage Description Gauge Finish 2543941 12"Striated 26 Galvalume® (ACG) 25439XX 12"Striated 26 MS Colorfast45® Painted (CF45) 26439XX 12"Striated 26 PVDF (Kynar 500®) Painted 2743841 12"Flat 24 Galvalume® (ACG) 2743941 12"Striated 24 Galvalume® (ACG) 28438XX 12"Flat 24 PVDF (Kynar 500®) Painted 28439XX 12"Striated 24 PVDF (Kynar 500®) Painted 2545941 16"Striated 26 Galvalume® (ACG) 25459XX 16"Striated 26 MS Colorfast45® Painted (CF45) 26459XX 16"Striated 26 PVDF (Kynar 500®) Painted 2745641 16"Flat 24 Galvalume® (ACG) 2745941 16"Striated 24 Galvalume® (ACG) 28456XX 16"Flat 24 PVDF (Kynar 500®) Painted 28456XX 16"Striated 24 PVDF (Kynar 500®) Painted 2546241 18"Striated 26 Galvalume® (ACG) 25462XX 18"Striated 26 MS Colorfast45® Painted (CF45) 26462XX 18"Striated 26 PVDF (Kynar 500®) Painted 2746041 18"Flat 24 Galvalume® (ACG) 2746241 18"Striated 24 Galvalume® (ACG) 28460XX 18"Flat 24 PVDF (Kynar 500®) Painted 28462XX 18"Striated 24 PVDF (Kynar 500®) Painted Vertical Seam Panels 12",1 6" or 18" Coverage with Striations Factory-Applied Sealant 1-3/4" 12",1 6" or 18" Coverage Flat Pan Factory-Applied Sealant 1-3/4" 12", 16", or 18" Coverage 12", 16", or 18" Coverage 13/4" 13/4" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 5 RESIDENTIAL DESIGN GUIDE 1. Theoretical section properties have been calculated per AISI 2012 'North American Specification for the Design of Cold- Formed Steel Structural Members'. Ixx and Sxx are effective section properties for deflection and bending. 2. Allowable loads are calculated in accordance with AISI 2012 specifications considering bending, shear, combined bend- ing and shear, deflection and ASTM E 1592 uplift testing for 24 ga and UL 580 uplift testing for 26 ga. Allowable loads consider the 3 or more equal spans condition. Allowable loads do not address web crippling, fasteners or support material. Panel weight is not considered. 3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span. 4. Allowable loads do not include a 1/3 stress increase for wind. - indicates testing is not available for the application. SECTION PROPERTIES ALLOWABLE UNIFORM LOADS, psf For various fastener spacings Ga.Width in Yield ksi Weight psf Top In Compression Bottom In Compression Inward Load Outward LoadIxx in4/ft Sxx in3/ft Ixx in4/ft Sxx in3/ft 2.5'3'3.5'4'4.5'5'2.5'3'3.5'4'4.5'5' 26 12 50 1.06 0.0781 0.0530 0.0377 0.0408 148 104 77 59 --55 49 42 36 -- 26 16 50 0.97 0.0614 0.0402 0.0283 0.0306 114 79 58 45 --55 49 42 36 -- 26 18 50 0.94 0.0553 0.0358 0.0253 0.0273 ------------ 24 12 50 1.38 0.1118 0.0774 0.0533 0.0557 204 143 105 81 64 52 44 43 42 41 40 39 24 16 50 1.26 0.0885 0.0589 0.0398 0.0419 153 107 79 61 48 39 42 38 34 30 27 24 24 18 50 1.22 0.0800 0.0526 0.0353 0.0372 136 95 70 54 43 35 33 30 27 24 20 19 ATTACHMENT DETAIL PANEL CLIPS Clip Vertical Seam Panel  Slope  Clips  Coverage  Lengths  Fasteners  Availability GENERAL INFORMATION The minimum recommended slope for the Vertical Seam roof panel is 3:12 over open framing and 1:12 over solid substrate. Clip spacing is based upon the spacing of structural framing members and loading requirements. Vertical Seam panels are available in a 13/4" seam height with a 12", 16", or 18" width coverage. Minimum factory cut length is 5'-0". Maximum recommended panel length is 45'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult Metal Sales for recommendations. The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements. NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. Finishes: in PVDF (Kynar 500®), MS Colorfast45®, and Acrylic Coated Galvalume®. Gauges: 24 gauge or 26 gauge Pancake Head Fastener Factory-Applied Sealant Base Vertical Tab UL90 Clip - 2 Fasteners Vertical Seam Design Information © Metal Sales Manufacturing Corporation / Subject to change without notice 4/176 RESIDENTIAL DESIGN GUIDE Product No.Coverage Description Gauge Finish 2544141 12"Striated 26 Galvalume® (ACG) 2514641 12"Minor Rib 26 Galvalume® (ACG) 25441XX 12"Striated 26 MS Colorfast45® Painted (CF45) 25146XX 12"Minor Rib 26 MS Colorfast45® Painted (CF45) 26441XX 12"Striated 26 PVDF (Kynar 500®) Painted 2718841 12"Striated 24 Galvalume® (ACG) 2718641 12"Minor Rib 24 Galvalume® (ACG) 27188XX 12"Striated 24 PVDF (Kynar 500®) Painted 27186XX 12"Minor Rib 24 PVDF (Kynar 500®) Painted 2534641 16"Minor Rib 26 Galvalume® (ACG) 25444XX 16"Striated 26 MS Colorfast45® Painted (CF45) 25346XX 16"Minor Rib 26 MS Colorfast45® Painted (CF45) 26444XX 16"Striated 26 PVDF (Kynar 500) Painted 2718741 16"Striated 24 Galvalume® (ACG) 2718941 16"Minor Rib 24 Galvalume® (ACG) 27187XX 16"Striated 24 PVDF (Kynar 500®) Painted 27189XX 16"Minor Rib 24 PVDF (Kynar 500®) Painted Image II Panels 12" or 16" Coverage 1"with Striations Flat Pan 12" or 16" Coverage 1" 16" Coverage 1"with Minor Ribs 1"with Minor Ribs 12" Coverage 12" or 16" Coverage 1"with Striations Flat Pan 12" or 16" Coverage 1" 16" Coverage 1"with Minor Ribs 1"with Minor Ribs 12" Coverage 16" Coverage 1" 16" Coverage 1" 12" Coverage 1" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 7 RESIDENTIAL DESIGN GUIDE SECTION PROPERTIES ALLOWABLE UNIFORM LOADS, psf For various fastener spacings Ga.Width in Yield ksi Weight psf Top In Compression Bottom In Compression Outward LoadIxx in4/ft Sxx in3/ft Ixx in4/ft Sxx in3/ft 0'-6"1'-0"1'-6"2'-0" 26 16 50 0.92 0.0165 0.0174 0.0165 0.0177 103 96 90 84 24 16 50 1.19 0.0210 0.0226 0.0210 0.0226 103 96 90 84  Slope  Substructure  Coverage  Length  Fasteners  Availability GENERAL INFORMATION The minimum recommended slope for the Image II roof panel is 3:12. Image II is designed to be utilized over a solid substrate. To avoid panel distortion use a properly aligned and uniform substructure. NOTE: Image II roof panels are not recommended for use over open structural framing. Image II panels are available in a 1" seam height with a 12" or 16" width coverage. Minimum factory cut length is 5'-0". Maximum recommended panel length is 30'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult Metal Sales for recommendations. The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements. NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. Finishes: Acrylic Coated Galvalume®, MS Colorfast45®, or various PVDF (Kynar 500®) colors. Gauges: 26 gauge or 24 gauge ATTACHMENT DETAIL FASTENING PATTERN Image II Panel Woodscrew Image II Design Information 1. Theoretical section properties have been calculated per AISI 2012 'North American Specification for the Design of Cold- Formed Steel Structural Members'. Ixx and Sxx are effective section properties for deflection and bending. 2. Allowable loads are calculated in accordance with AISI 2012 specifications considering bending, shear, combined bending and shear, deflection and UL 580 uplift testing for 26 ga using #10-12x1" Pancakehead Wood Screw into 5/8" plywood. Allowable loads consider the 3 or more equal spans condition. Allowable loads do not address web crippling, fasteners or support material. Panel weight is not considered. 3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span. 4. Allowable loads do not include a 1/3 stress increase for wind. Panel Fasteners © Metal Sales Manufacturing Corporation / Subject to change without notice 4/178 RESIDENTIAL DESIGN GUIDE VERTICAL SEAM RESIDENTIAL PEAK Product No.Length Gauge Finish 5013341 10'-2"26 Galvalume (ACG) 50133XX 10'-2"26 CF45 Painted 51133XX 10'-2"26 PVDF Painted 5213341 10'-2"24 Galvalume (ACG) 52133XX 10'-2"24 PVDF Painted Flashing Stretch Out = 13" 7" RIDGE/HIP COVER Product No.Length Gauge Finish 5013141 10'-2"26 Galvalume (ACG) 50131XX 10'-2"26 CF45 Painted 51131XX 10'-2"26 PVDF Painted 5213141 10'-2"24 Galvalume (ACG) 52131XX 10'-2"24 PVDF Painted Flashing Stretch Out = 16" 5" RIDGE/HIP COVER Product No.Length Gauge Finish 5013041 10'-2"26 Galvalume (ACG) 50130XX 10'-2"26 CF45 Painted 51130XX 10'-2"26 PVDF Painted 5213041 10'-2"24 Galvalume (ACG) 52130XX 10'-2"24 PVDF Painted Flashing Stretch Out = 12" C 1" 7" 37/8" 5/8" Open Hem Open Hem 1/2" IMAGE II RESIDENTIAL PEAK Product No.Length Gauge Finish 5013441 10'-2"26 Galvalume (ACG) 50134XX 10'-2"26 CF45 Painted 51134XX 10'-2"26 PVDF Painted 5213441 10'-2"24 Galvalume (ACG) 52134XX 10'-2"24 PVDF Painted Flashing Stretch Out = 121/8" C 1" 7" 3" 5/8" Open Hem Open Hem 1/2" C C 7" 5" Open Hem Open Hem 1" 1" 135º 135º Flashing Profiles Specify Pitch Specify Pitch Specify Pitch Specify Pitch © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 9 RESIDENTIAL DESIGN GUIDE RESIDENTIAL PITCH BREAK Product No.Length Gauge Finish 5394341 10'-2"26 Galvalume (ACG) 53943XX 10'-2"26 CF45 Painted 51143XX 10'-2"26 PVDF Painted 5294341 10'-2"24 Galvalume (ACG) 52943XX 10'-2"24 PVDF Painted Flashing Stretch Out = 11"C 1" 6" NOTE: 6" dimension will not work in all applications. Provide slopes of adjoining planes 4" Open Hem Specify Pitch RESIDENTIAL RAKE CLEAT Product No.Length Gauge Finish 5013241 10'-2"26 Galvalume (ACG) 50132XX 10'-2"26 CF45 Painted 51132XX 10'-2"26 PVDF Painted 5213241 10'-2"24 Galvalume (ACG) 52132XX 10'-2"24 PVDF Painted Flashing Stretch Out = 5" VERTICAL SEAM RESIDENTIAL RAKE Product No.Length Gauge Finish 5012741 10'-2"26 Galvalume (ACG) 50127XX 10'-2"26 CF45 Painted 51127XX 10'-2"26 PVDF Painted 5212741 10'-2"24 Galvalume (ACG) 52127XX 10'-2"24 PVDF Painted Flashing Stretch Out = 61/4" C13/4" 33/8" 5/8" 1/2" IMAGE II RESIDENTIAL RAKE Product No.Length Gauge Finish 5012641 10'-2"26 Galvalume (ACG) 51026XX 10'-2"26 CF45 Painted 51126XX 10'-2"26 PVDF Painted 5212641 10'-2"24 Galvalume (ACG) 52126XX 10'-2"24 PVDF Painted Flashing Stretch Out = 43/4" C C 1" 25/8" 11/2" 27/8" 5/8" 5/8" 135º 1/2" 135º 135º Flashing Profiles 45º 45º © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1710 RESIDENTIAL DESIGN GUIDE Flashing Profiles FLAT CLEAT (Field Cut to 1" Pieces)Product No.Length Gauge Finish 5506199 10'-2"26 Varies 5806199 10'-2"24 Varies 1" 23/4" 3/4" COUNTER FLASHING FLAT Product No.Length Gauge Finish 5552841 10'-2"26 Galvalume (ACG) 55528XX 10'-2"26 CF45 Painted 56528XX 10'-2"26 PVDF Painted 5852841 10'-2"24 Galvalume (ACG) 58528XX 10'-2"24 PVDF Painted Flashing Stretch Out = 47/8" REGLET FLASHING Product No.Length Gauge Finish 5552641 10'-2"26 Galvalume (ACG) 55526XX 10'-2"26 CF45 Painted 56526XX 10'-2"26 PVDF Painted 5852641 10'-2"24 Galvalume (ACG) 58526XX 10'-2"24 PVDF Painted Flashing Stretch Out = 55/8" COUNTER FLASHING Product No.Length Gauge Finish 5552741 10'-2"26 Galvalume (ACG) 55527XX 10'-2"26 CF45 Painted 56527XX 10'-2"26 PVDF Painted 5852741 10'-2"24 Galvalume (ACG) 58527XX 10'-2"24 PVDF Painted Flashing Stretch Out = 6" COUNTER FLASHING RECEIVER Product No.Length Gauge Finish 5552941 10'-2"26 Galvalume (ACG) 55529XX 10'-2"26 CF45 Painted 56529XX 10'-2"26 PVDF Painted 5852941 10'-2"24 Galvalume (ACG) 58529XX 10'-2"24 PVDF Painted Flashing Stretch Out = 93/8" 1" Open Hem 3/4" 2" 1/2" 5/8" 45° Open Hem 1/2" 5/8" 1/2"1" 3" 82° 135° Open Hem 1/2" 5/8" 1" Open Hem 3/4" 2" 1/2" 5/8" 118° 135° 135° 135° 118° 137° 135° 1/2" 21/2" Open Pocket13/4" 5/8" 21/2" 11/2" 95° 165° 95° Flashing Stretch Out = 31/2" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 11 RESIDENTIAL DESIGN GUIDE RESIDENTIAL EAVE Product No.Length Gauge Finish 5002241 10'-2"26 Galvalume (ACG) 50022XX 10'-2"26 CF45 Painted 51122XX 10'-2"26 PVDF Painted 5202241 10'-2"24 Galvalume (ACG) 52022XX 10'-2"24 PVDF Painted Flashing Stretch Out = 81/2" RESIDENTIAL CLEAT Product No.Length Gauge Finish 5013599 10'-2"26 Varies 5213599 10'-2"24 Varies Flashing Stretch Out = 3" RESIDENTIAL W-VALLEY Product No.Length Gauge Finish 5013641 10'-2"26 Galvalume (ACG) 50136XX 10'-2"26 CF45 Painted 51136XX 10'-2"26 PVDF Painted 5213641 10'-2"24 Galvalume (ACG) 52136XX 10'-2"24 PVDF Painted Flashing Stretch Out = 233/4" RESIDENTIAL EXTENDED EAVE Product No.Length Gauge Finish 5102441 10'-2"26 Galvalume (ACG) 51024XX 10'-2"26 CF45 Painted 51124XX 10'-2"26 PVDF Painted 5212441 10'-2"24 Galvalume (ACG) 52124XX 10'-2"24 PVDF Painted Flashing Stretch Out = 10" C C C Open Hem 1/2" 5/8" 5" 10" 1" 7/8" 5/8" 17/8" 1/2" Open Hem Open Hem 11/2" 7/8" Specify Pitch C Open Hem 1/2" 5/8" 5" Open Hem 11/2"11/2" 7/8" 135º 135º 135º 70º Specify Pitch Specify Pitch 160º Flashing Profiles RESIDENTIAL RAKEWALL Product No.Length Gauge Finish 5012941 10'-2"26 Galvalume (ACG) 50129XX 10'-2"26 CF45 Painted 51129XX 10'-2"26 PVDF Painted 5212941 10'-2"24 Galvalume (ACG) 52129XX 10'-2"24 PVDF Painted Flashing Stretch Out = 87/8" C Open Hem 11/2" 6" Open Hem 13/8" 135º 135º © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1712 RESIDENTIAL DESIGN GUIDE VERTICAL SEAM END CAP Product No.Length Gauge Finish 5011041 10'-2"26 Galvalume (ACG) 50110XX 10'-2"26 CF45 Painted 51110XX 10'-2"26 PVDF Painted 5211041 10'-2"24 Galvalume (ACG) 52110XX 10'-2"24 PVDF Painted Flashing Stretch Out = 4" IMAGE II END CAP Product No.Length Gauge Finish 5011141 10'-2"26 Galvalume (ACG) 50111XX 10'-2"26 CF45 Painted 51111XX 10'-2"26 PVDF Painted 5211141 10'-2"24 Galvalume (ACG) 52111XX 10'-2"24 PVDF Painted Flashing Stretch Out = 31/4" 2" 1" 1" 11/4" 1" 1" OFFSET CLEAT Product No.Length Gauge Finish 5506499 10'-2"26 Varies 5806499 10'-2"24 Varies Flashing Stretch Out = 3" C 11/2"1" 1/2" Flashing Profiles VERTICAL SEAM Z-CLOSURE Product No.Length Gauge Finish 5570241 10'-2"26 Galvalume (ACG) 55702XX 10'-2"26 CF45 Painted 56702XX 10'-2"26 PVDF Painted 5870241 10'-2"24 Galvalume (ACG) 58702XX 10'-2"24 PVDF Painted Flashing Stretch Out = 33/4" IMAGE II Z-CLOSURE Product No.Length Gauge Finish 5560341 10'-2"26 Galvalume (ACG) 55603XX 10'-2"26 CF45 Painted 56603XX 10'-2"26 PVDF Painted 5860341 10'-2"24 Galvalume (ACG) 58603XX 10'-2"24 PVDF Painted Flashing Stretch Out = 3" C C 1" 1" 1" 1" 1" 13/4" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 13 RESIDENTIAL DESIGN GUIDE Accessories TUBE SEALANT Product No.Length Weight Finish 6403200 Acrylic Tube Sealant 3.31 lbs Clear 64032XX Tube Sealant 3.31 lbs Color Match DOUBLE BEAD TAPE SEALANT Product No.Length Weight Color 6403899 25'-0"1.75 lbs Gray PROFILE VENT Product No.Panel Profile Length Type 6462118 16" Vertical Seam 100'Notched 6462119 18" Vertical Seam 100'Notched 6441799 12" Image II 100'Notched 6441898 16" Image II 50'Notched 6441899 16" Image II 100'Notched PROFILE VENT CLIPS Product No.Length Height Finish 6541000 Vertical Seam 13/4"Black 6540000 Image II 1"Black VERTICAL SEAM CLIP Product No.Height Weight/Ea Finish 4923565 13/4"0.15 lbs Galvanized © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1714 RESIDENTIAL DESIGN GUIDE Tools TURBO SHEARS Product No. 6534599 VERSA HEMMER Product No. 6531499 20" DUAL BAR FOLDER/HEMMER Product No. 6531299 VERSA BENDER DOUBLE STATION Product No. 6531699 VERSA BENDER SINGLE Product No. 6531599 © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 15 RESIDENTIAL DESIGN GUIDE POP RIVET Product No.Description WT/250 Finish 8240901 1/8" x 3/16" Stainless Steel 0.75 lbs Bare 82409XX 1/8" x 3/16" Stainless Steel 0.75 lbs Painted PANCAKE HEAD WOOD SCREW Product No.Description WT/250 Finish 8243100 #10-12 x 1" PH Wood Screw 1.90 lbs Plated TRUSS HEAD WOOD SCREW Product No.Description WT/250 Finish 8243300 #8-15 x 1" TH Wood Screw 1.90 lbs Plated WOOD SCREW Product No.Description WT/250 Finish 82103XX #10-14 x 11/2" Wood Screw 2.75 lbs Painted WOOD SCREW XL Product No.Description WT/250 Finish 8212300 #10-14 x 11/2" Wood Screw XL 3.75 lbs Plated 82123XX #10-14 x 11/2" Wood Screw XL 3.75 lbs Painted STITCH Product No.Description WT/250 Finish 82348XX 1/4"-14 x 7/8" Stitch 3.85 lbs Painted STITCH XL Product No.Description WT/250 Finish 8236800 1/4"-14 x 7/8" Stitch XL 5.25 lbs Plated 82368XX 1/4"-14 x 7/8" Stitch XL 5.25 lbs Painted METALWOOD SCREW Product No.Description WT/250 Finish 8215100 #14 x 11/2" Metalwood screw 3.75 lbs Plated 82151XX #14 x 11/2" Metalwood screw 3.75 lbs Painted Fasteners © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1716 RESIDENTIAL PRODUCT GUIDE Vertical Seam Eave u v x y z Hem flat pan of panel to accept Offset Cleat Part Description Product No.Length Installation Information 1 Residential Eave 50022XX 26 Gauge 10'-2" Wrap cardboard around panel hem when crimping closed to the Offset Cleat. Telescope notch the Eave flashing 3" at all lap locations. 2 Offset Cleat 5506499 26 Gauge 10'-2" Offset Cleat should be installed so that the edge aligns with the fascia board. 3 Pancake Head Wood Screw 8243100 1" 1 every 6" fastened through the Offset Cleat and Double Bead Tape Sealant. 4 Double Bead Tape Sealant 6403899 25'Continuous Double Bead Tape Sealant under Offset Cleat. 5 Tube Sealant 6403200 64032XX Apply 2 continuous vertical beads of Tube Sealant to the male leg of the panel as shown. 6 Tube Sealant 6403200 64032XX Apply continuous bead of Tube Sealant to the open hem of the panel. C C Tube Sealant on top of the male rib 6" up from the end of the panel w © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 17 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Residential Extended Eave 51024XX 26 Gauge 10'-2" Wrap cardboard around panel hem when crimping closed to the Extended Eave. Telescope notch the Extended Eave flashing 3" at all lap locations. 2 Pancake Head Wood Screw 8243100 1" Fasten 6" o.c. to hold Extended Eave Flashing in place. 3 Double Bead Tape Sealant 6403899 25' Apply continuous Double Bead Tape Sealant on Extended Eave below Pancake Head Wood Screws. 4 Tube Sealant 6403200 64032XX Apply 2 continuous beads of Tube Sealant to the male leg of the panel as shown. Vertical Seam Extended Eave C u w u Hem flat of panel to accept Extended Eave Flashing Tube Sealant on top of the male rib 6" up from the end of the panel v x © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1718 RESIDENTIAL DESIGN GUIDE Vertical Seam Residential Valley u Part Description Product No.Length Installation Information 1 Residential W-Valley 50136XX 26 Gauge 10'-2" Always install W-Valley Flashing working from eave up slope. 2 Offset Cleat 5506499 26 Gauge 10'-2" Install Offset Cleat in a straight line from eave to high end of the valley, 6" from the center of the valley on each side. 3 Pancake Head Wood Screw 8243100 1"4 per 10' of length, to secure flashing in place. 4 Pancake Head Wood Screw 8243100 1"6" on center. Fasten through Double Bead Tape Sealant. 5 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant between Offset Cleat and Valley. 6 Tube Sealant 6403200 64032XX Apply 2 continuous vertical beads of Tube Sealant to the male leg of the panel and along the top of the rib. 7 Tube Sealant 6403200 64032XX Apply continuous bead of Tube Sealant to the open hem of the panel. C x z C { Bend the flat pan of panel around to accept offset cleat 6" v w y Tube Sealant on top of the male rib 6" up from the end of the panel © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 19 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Vertical Seam Residential Rake 50127XX 26 Gauge 10'-2" Rake Flashing hooked over the panel edge. Attach to the Rake Cleat. Pinch hem closed along the entire rake edge. 2 Residential Rake Cleat 50132XX 26 Gauge 10'-2" Fasten Rake Cleat to substrate with either Truss Head or Pancake Head Wood Screw. 3 Flat Cleat 5506199 26 Gauge 10'-2" Field cut to 1" wide cleats. Installed over panel edge spaced 18" o.c. or to match panel fastener spacing. Fasten with Pancake Head Wood Screws. 4 Pancake Head Wood Screw 8243100 1"1 per lineal foot of condition to 18" o.c. 5 Pancake Head Wood Screw 8243100 1" 1 per Flat Cleat. 18" o.c. or to match panel fastener spacing. 6 1/8" x 3/16" Pop Rivet 82409XX Install single Pop Rivet through the Rake into the Rake Cleat. Vertical Seam Residential Rake u v w x C C y Turn panel up 13/4" along rake edge 3" 2" Field telescope notch Vertical Seam Residential Rake Flashing Lap Detail z 1" 23/4" 3/4" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1720 RESIDENTIAL DESIGN GUIDE Rakewall w/ Counter Flashing Description Installation Information 1 Tube Sealant Fill the space between the Counter Flashing and the wall. 2 Fastener by Others Fasten as shown 3 Residential Counter Flashing Fasten to wall over Residential Rakewall flashing. 4 Fastener by Others Fasten as shown 5 Residential Rakewall Slide Residential Rakewall over the Image II panel edge. 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket. 7 Tube Sealant Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing. Push flashing down over the panel turn-up and into the sealant. Wipe away excess sealant with finger or plastic caulk smoothing tool. 8 Vertical Seam Panel Turn up panel 13/8" for Rakewall Slip Pocket © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 21 RESIDENTIAL DESIGN GUIDE Rakewall w/ Counter & Receiver Detail for Installation of Siding Prior to Panels Description Installation Information 1 Residential Counter Flashing Receiver Install bottom edge of flashing 51/2" up from the substrate. 2 Fastener by Others Fasten as shown 3 Pop Rivet Fasten Receiver to the Counter Flashing 12" o.c. 4 Residential Counter Flashing Flat Slide into open hem of Counter Flashing Receiver 5 Residential Rakewall Slide Residential Rakewall over the Image II panel edge. 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket. 7 Tube Sealant Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing. Push flashing down over the panel turn-up and into the sealant. Wipe away excess sealant with finger or plastic caulk smoothing tool. 8 Vertical Seam Panel Turn up panel 13/8" for Rakewall Slip Pocket 51/2" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1722 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Residential Rakewall 50129XX 26 Gauge 10'-2" Slide Residential Rakewall over the Vertical Seam panel edge. 2 Tube Sealant 6403200 64032XX Apply a continuous bead of Tube Sealant to the slip pocket. 3 Tube Sealant 6403200 64032XX Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing. Push flashing down over the panel turn-up and into the sealant. Wipe away excess sealant with finger or plastic caulk smoothing tool. Vertical Seam Rakewall u v Vertical Seam Panel turn up 1-3/8" C 3" 2" Field telescope notch Residential Rakewall Flashing Lap Detail Slip Pocket w © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 23 RESIDENTIAL PRODUCT GUIDE Vertical Seam Hip / Non-Vented Ridge u v x w Part Description Product No.Length Installation Information 1 7" Ridge/Hip Cover 5" Ridge/Hip Cover 50131XX 26 Gauge 50130XX 26 Gauge 10'-2"Slide Ridge/Hip Cover over top flange of Z-Closures. 2 Vertical Seam Z-Closure 55702XX 26 Gauge 10'-2"1" end tabs on Z-Closure. 3 Pancake Head Wood Screw 8243100 1" 4 required at every Z-Closure fastening through the Z-Closure and Double Bead Tape Sealant. 4 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant required over face of panels and up and over ribs. C C C7" 5" Section A-A Turn up flat pan of each panel 45° at the ridge/hip condition © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1724 RESIDENTIAL PRODUCT GUIDE Vertical Seam Ridge/Hip Notch Detail Description Installation Information 1 Ridge/Hip Cover Telescope notch each piece 3" at high side and fasten to the adjacent Ridge/Hip Flashing with a Pop Rivet on each side. 2 Pop Rivet 2 Pop Rivets per notched tab, attaching the flashings. 3 Tube Sealant Apply two rows of Tube Sealant between the two lapped flashings. u v w © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 25 RESIDENTIAL PRODUCT GUIDE Vertical Seam Hip End Cap Detail u v w y Description Installation Information 1 Ridge/Hip Cover Open hems of the Hip Flashing slide onto 1" top flanges of Z-Closure. Fold 1" hems over top flashings of Vertical Seam end cap. Attach high side of flashing as shown on page 24. 2 Vertical Seam Z-Closure Z-Closures over continuous Double Bead Tape Sealant. 3 Pancake Head Wood Screw Attach Vertical Seam Z-Closures with Pancake Head Wood Screws or Truss Head Wood Screws. 4 Double Bead Tape Sealant Double Bead Tape Sealant required under Z-Closures and over panel ribs. A weep hole/gap in the Double Bead Tape Sealant is required at the low side of the Z-Closure, along the panel rib. 5 Vertical Seam Panel Turn the Vertical Seam panel ends turned up to vertical 1" at the hip. 6 Vertical Seam End Cap Lower flange of End Cap covers the panel hem. 7 Pop Rivet 2 Pop Rivets per miter, attaching End Caps to the Z-Closures. A A x z v u z{{ 1/2"-1" miter, depending on slope © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1726 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Residential Pitch Break 53943XX 26 Gauge 10'-2"Open hem hooks onto Z-Closure. 2 Vertical Seam Z-Closure 55702XX 26 Gauge 10'-2"1" end tabs on Z-Closure. 3 Pancake Head Wood Screw 8243100 1" 4 required at every Z-Closure fastening through the Double Bead Tape Sealant. 4 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant required over face of panels and up and over ribs. Continuous Double Bead Tape Sealant required over top of Z-Closures. C C u v w x Fastener by Others Vertical Seam Pitch Break u © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 27 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Vertical Seam Residential Peak 50133XX 26 Gauge 10'-2" Peak flashing face can be attached directly to substrate or hooked on optional Residential Cleat. 2 Profile Vent Notched 16" 6462118 Notched 18" 6462119 100'Lay over panel ribs between Peak Flashing and panel. 3 Vertical Seam Profile Vent Clip 6541000 31/8" Place over Profile Vent and fasten with two 11/2" Metalwood screws. Install 2 clips per panel. 4 #14-11/2" Metalwood Screw 8215100 11/2" 2 per Profile Vent Clip. Fasten through Double Bead Tape Sealant on the low side. 5 #10-14 x 11/2" Wood Screw 82103XX 11/2" 1 per lineal foot of condition. *Optional Pancake Head Wood Screw can be used with Residential Cleat. 6 1/8" x 3/16" Pop Rivet 82409XX Fasten Pop Rivet through the Peak into the Profile Vent Clip. *Optional install Stitch Screw. C u w u Vertical Seam Vented Peak RESIDENTIAL CLEAT OPTIONAL INSTALLATION z { { vx y x © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1728 RESIDENTIAL PRODUCT GUIDE A B u v Vertical Seam Peak x y Part Description Product No.Length Installation Information 1 Vertical Seam Residential Peak 50133XX 26 Gauge 10'-2" Peak flashing face can be attached directly to substrate or hooked on Residential Cleat. 2 Vertical Seam Z-Closure 55702XX 26 Gauge 10'-2"1" end tabs on Z-Closure. 3 Residential Cleat 5013599 26 Gauge 10'-2" Optional concealed fastener installation. Fasten with Pancake Head Wood Screws 1 per lineal foot. 4 #10-14 x 11/2" Wood Screw 82103XX 11/2" 1 per lineal foot Not used if optional Residential Cleat is installed. 5 Pancake Head Wood Screw 8243100 1" 4 at every Z-Closure fastening through the Double Bead Tape Sealant. 6 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant required over face of panels and up and over ribs. u z C C C w y OPTIONAL CLEAT INSTALLATION y © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 29 RESIDENTIAL DESIGN GUIDE Peak Flashing Lap Details Panel Rib Z-Closure Pop Rivet 2 Rows of Tube Sealant Panel Rib Z-Closure Fastener Open Hem on Peak Flashing over Z-Closure Front of Residential Peak Pop Rivet 2 Rows of Tube Sealant Residential Cleat Open Hem on Peak Flashing over Z-Closure Top of Residential Peak A B Peak Flashing Lap - Front View Peak Flashing Lap - Top View Telescope Notch 3" Telescope Notch 3" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1730 RESIDENTIAL PRODUCT GUIDE Image II Eave u v x y z Bend flat pan of panel around to accept offset cleat Part Description Product No.Length Installation Information 1 Residential Eave 50022XX 26 Gauge 10'-2" Wrap cardboard around panel hem when crimping closed to the Offset Cleat. Telescope notch the Eave flashing 3" at all lap locations. 2 Offset Cleat 5506499 26 Gauge 10'-2" Offset Cleat should be installed so that the edge aligns with the fascia board. 3 Pancake Head Wood Screw 8243100 1" 1 required every 6" fastened through the offset Cleat and Double Bead Tape Sealant. 4 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant required under Offset Cleat. 5 Tube Sealant 6403200 64032XX Apply 2 continuous beads of Tube Sealant to the female leg of the panel as shown. 6 Tube Sealant 6403200 64032XX Fill in open hem of the panel with a continuous bead of Tube Sealant. C C Tube Sealant on top of the male rib 6" up from eave w © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 31 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Residential Extended Eave 51024XX 26 Gauge 10'-2" Wrap cardboard around panel hem when crimping closed to the Extended Eave. Telescope notch the Extended Eave flashing 3" at all lap locations. 2 Pancake Head Wood Screw 8243100 1" Fasten 6" o.c. to hold Extended Eave Flashing in place. 3 Double Bead Tape Sealant 6403899 25' Apply continuous line of Double Bead Tape Sealant on Extended Eave below Pancake Head Wood Screws. 4 Tube Sealant 6403200 64032XX Apply 2 continuous beads of Tube Sealant to the female leg of the panel as shown. Image II Extended Eave C u w u Bend flat pan of panel around to accept Extended Eave Flashing Tube Sealant on top of the male rib 6" up from eave v x © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1732 RESIDENTIAL PRODUCT GUIDE Image II Residential Valley u Part Description Product No.Length Installation Information 1 Residential W-Valley 50136XX 26 Gauge 10'-2" Always install W-Valley Flashing working from eave up slope. 2 Offset Cleat 5506499 26 Gauge 10'-2" Install Offset Cleat in a straight line from eave to high end of the valley, 6" from the center of the valley on each side. 3 Pancake Head Wood Screw 8243100 1"4 per 10' of length, to secure flashing in place. 4 Pancake Head Wood Screw 8243100 1"6" on center. Fasten through Double Bead Tape Sealant. 5 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant between Offset Cleat and Valley. 6 Tube Sealant 6403200 64032XX Apply 2 continuous vertical beads of Tube Sealant to the male leg of the panel and along the top of the rib. 7 Tube Sealant 6403200 64032XX Apply continuous bead of Tube Sealant to the open hem of the panel. C x z C { Bend the flat pan of panel around to accept offset cleat 6" v w y Tube Sealant on top of the male rib 6" up from eave © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 33 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Image II Residential Rake 50126XX 26 Gauge 10'-2" Rake Flashing hooked over the panel edge. Attach to the Rake Cleat. Pinch hem closed along the entire rake edge. 2 Residential Rake Cleat 50132XX 26 Gauge 10'-2" Fasten Rake Cleat to substrate with either Truss Head or Pancake Head Wood Screw. 3 Flat Cleat 5506199 26 Gauge 10'-2" Field cut to 1" wide cleats. Installed over panel edge spaced 18" o.c. or to match panel fastener spacing. Fasten with Pancake Head Wood Screws. 4 Pancake Head Wood Screw 8243100 1"1 per lineal foot of condition to 18" o.c. 5 Pancake Head Wood Screw 8243100 1" 1 per Flat Cleat, 18" o.c. or to match panel fastener spacing. 6 1/8" x 3/16" Pop Rivet 82409XX Install single Pop Rivet through the Rake into the Rake Cleat. Image II Residential Rake u v w x C C y Turn panel up 1" along rake edge 3" 2" Field telescope notch Image II Residential Rake Flashing Lap Detail z 1" 23/4" 3/4" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1734 RESIDENTIAL DESIGN GUIDE Rakewall w/ Counter Flashing Description Installation Information 1 Tube Sealant Fill the space between the Counter Flashing and the wall. 2 Fastener by Others Fasten as shown 3 Residential Counter Flashing Fasten to wall over Residential Rakewall flashing. 4 Fastener by Others Fasten as shown 5 Residential Rakewall Slide Residential Rakewall over the Image II panel edge. 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket. 7 Tube Sealant Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing. Push flashing down over the panel turn-up and into the sealant. Wipe away excess sealant with finger or plastic caulk smoothing tool. 8 Image II Panel Turn up panel 13/8" for Rakewall Slip Pocket © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 35 RESIDENTIAL DESIGN GUIDE Rakewall w/ Counter & Receiver Detail for Installation of Siding Prior to Panels Description Installation Information 1 Residential Counter Flashing Receiver Install bottom edge of flashing 51/2" up from the substrate. 2 Fastener by Others Fasten as shown 3 Pop Rivet Fasten Receiver to the Counter Flashing 12" o.c. 4 Residential Counter Flashing Flat Slide into open hem of Counter Flashing Receiver 5 Residential Rakewall Slide Residential Rakewall over the Image II panel edge. 6 Tube Sealant Apply a continuous bead of Tube Sealant to the slip pocket. 7 Tube Sealant Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing. Push flashing down over the panel turn-up and into the sealant. Wipe away excess sealant with finger or plastic caulk smoothing tool. 8 Image II Panel Turn up panel 13/8" for Rakewall Slip Pocket 51/2" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1736 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Residential Rakewall 50129XX 26 Gauge 10'-2"Slide Residential Rakewall over the Image II panel edge. 2 Tube Sealant 6403200 64032XX Apply a continuous bead of Tube Sealant to the slip pocket. 3 Tube Sealant 6403200 64032XX Apply a continuous bead of Tube Sealant to the inside corner of the panel prior to attaching the flashing. Push flashing down over the panel turn-up and into the sealant. Wipe away excess sealant with finger or plastic caulk smoothing tool. Image II Rakewall u v Image II Panel turn up 1-3/8" C 3" 2" Field telescope notch Residential Rakewall Flashing Lap Detail w © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 37 RESIDENTIAL PRODUCT GUIDE Image II Hip/Non-Vented Ridge u v x w Part Description Product No.Length Installation Information 1 7" Ridge/Hip Cover 5" Ridge/Hip Cover 50131XX 26 Gauge 50130XX 26 Gauge 10'-2"Slide Ridge/Hip Cover over top flange of Z-Closures. 2 Image II Z-Closure 55603XX 26 Gauge 10'-2"1" end tabs on Z-Closure. 3 Pancake Head Wood Screw 8243100 1" 4 at every Z-Closure fastening through the Z-Closure and Double Bead Tape Sealant. 4 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant required over face of panels and up and over ribs. C C C7" 5" Section A-A Turn up flat pan of each panel 45° at the ridge/hip condition © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1738 RESIDENTIAL PRODUCT GUIDE Image II Hip/Ridge Notch Detail Description Installation Information 1 Ridge/Hip Cover Telescope notch each piece 3" at high side and fasten to the adjacent Ridge/Hip Flashing with a Pop Rivet on each side. 2 Pop Rivet 2 Pop Rivets per notched tab, attaching the flashings. 3 Tube Sealant Apply two rows of Tube Sealant between the two lapped flashings. u v w © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 39 RESIDENTIAL PRODUCT GUIDE Image II Hip End Cap Detail u v w y Description Installation Information 1 Ridge/Hip Cover Open hems of the Hip Flashing slide onto 1" top flanges of Z-Closure. Fold 1" hems over top flashings of Image II end cap. Attach high side of flashing as shown on page 38. 2 Image II Z-Closure Z-Closures over continuous Double Bead Tape Sealant. 3 Pancake Head Wood Screw Attach Image II Z-Closures with Pancake Head Wood Screws or Truss Head Wood Screws. 4 Double Bead Tape Sealant Double Bead Tape Sealant required under Z-Closures and over panel ribs. A weep hole/gap in the Double Bead Tape Sealant is required at the low side of the Z-Closure, along the panel rib. 5 Image II Panel Turn the Image II panel ends turned up to vertical 1" at the hip. 6 Image II End Cap Lower flange of End Cap covers the panel hem. 7 Pop Rivet 2 Pop Rivets per miter, attaching End Caps to the Z-Closures. A A x z v u z{{ 1/2"-1" miter, depending on slope © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1740 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Residential Pitch Break 53943XX 26 Gauge 10'-2"Open hem hooks onto Z-Closure. 2 Image II Z-Closure 55603XX 26 Gauge 10'-2"1" end tabs on Z-Closure 3 Pancake Head Wood Screw 8243100 1" 4 required at every Z-Closure fastening through the Double Bead Tape Sealant. 4 Double Bead Tape Sealant 6403899 25'-0" Continuous Double Bead Tape Sealant required over face of panels and up and over ribs. Continuous Double Bead Tape Sealant required over top of Z-Closures. C C u v w x Fastener by Others Image II Pitch Break u © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 41 RESIDENTIAL PRODUCT GUIDE Part Description Product No.Length Installation Information 1 Residential Peak 50134XX 26 Gauge 10'-2" Peak flashing face can be attached directly to substrate or hooked on optional Residential Cleat. 2 Profile Vent Notched 12" 6441799 Notched 16" 6441899 100'Lay over panel ribs between Peak Flashing and panel. 3 Image II Profile Vent Clip 6540000 31/8" Place over Profile Vent and fasten with two 11/2" Metalwood screws. Install 2 clips per panel. 4 #14-11/2" Metalwood Screw 8215100 11/2" 2 per Profile Vent Clip. Fasten through Double Bead Tape Sealant on the low side. 5 #10-14 x 11/2" Wood Screw 82103XX 11/2" 1 per lineal foot of condition. *Optional Pancake Head Wood Screw can be used with Residential Cleat. 6 1/8" x 3/16" Pop Rivet 82409XX Fasten Pop Rivet through the Peak into the Profile Vent Clip. *Optional install Stitch Screw. C u v w x u Image II Vented Peak y RESIDENTIAL CLEAT OPTIONAL INSTALLATION z { x { © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1742 RESIDENTIAL PRODUCT GUIDE A B u v Image II Peak x y Part Description Product No.Length Installation Information 1 Residential Peak 50134XX 26 Gauge 10'-2" Peak flashing face can be attached directly to substrate or hooked on Residential Cleat. 2 Image II Z-Closure 55603XX 26 Gauge 10'-2"1" tabs required on Z-Closure. 3 Residential Cleat 5013599 26 Gauge 10'-2" Optional concealed fastener installation. Fasten with Pancake Head Wood Screws 1 per lineal foot. 4 #10-14 x 11/2" Wood Screw 82103XX 11/2" 1 per lineal foot of condition. Not used if optional Residential Cleat is installed. 5 Pancake Head Wood Screw 8243100 1" 4 required at every Z-Closure fastening through the Double Bead Tape Sealant. 1 per lineal foot of Offset Cleat. 6 Double Bead Tape Sealant 6403899 25' Continuous Double Bead Tape Sealant required over face of panels and up and over ribs. u z C C C w y OPTIONAL CLEAT INSTALLATION y © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 43 RESIDENTIAL DESIGN GUIDE Peak Flashing Lap Details Panel Rib Z-Closure Pop Rivet 2 Rows of Tube Sealant Panel Rib Z-Closure Fastener below Open Hem on Peak Flashing over Z-Closure Front of Residential Peak Pop Rivet 2 Rows of Tube Sealant Residential Cleat Open Hem on Peak Flashing over Z-Closure Top of Residential Peak A B Peak Flashing Lap - Front View Peak Flashing Lap - Top View Telescope Notch 3" Telescope Notch 3" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1744 RESIDENTIAL PRODUCT GUIDE Skylight/Chimney Detail SKYLIGHT INSTALLATION CHIMNEY INSTALLATION Part Description Product No.Length Installation Information LO W S I D E O F S K Y L I G H T / C H I M N E Y Residential Pitch Break 53943XX 26 Gauge 10'-2"Cut 2'-0" longer than the width of the Skylight or Chimney. Vertical Seam Z-Closure Image II Z-Closure 55702XX 26 Gauge 55603XX 26 Gauge 10'-2"1" end tabs on Z-Closure. Pancake Head Wood Screw 8243100 1" 4 required at every Z-Closure fastening through the Double Bead Tape Sealant. Double Bead Tape Sealant 6403899 25'-0" Continuous Double Bead Tape Sealant over face of panels and up and over ribs. Continuous Double Bead Tape Sealant over top of Z-Closures. Tube Sealant 6403200 64032XX Fill in gaps as needed. C C © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 45 RESIDENTIAL DESIGN GUIDE Skylight/Chimney Detail cont. Part Description Product No.Length Installation Information RI G H T A N D L E F T S I D E Residential Rakewall 50129XX 26 Gauge 10'-2" Cut the Residential Rakewall 2'-0" longer than the length of the Skylight or Chimney. Use a single flashing, no laps. Slide Residential Rakewall over the vertical panel edge. Tube Sealant 6403200 64032XX Apply a continuous bead of Tube Sealant to the slip pocket and inside corner of panel (see rakewall detail). C Part Description Product No.Length Installation Information HI G H S I D E O F S K Y L I G H T / C H I M N E Y Flat Sheet 25683XX 26 Gauge 10'-2" Flat pan only - Use full sheet for fabrication of cricket. 12" plus height up the Skylight/Chimney. x Dimension from full panel rib on each side of the Skylight/Chimney. Offset Cleat 5506499 26 Gauge 10'-2" Cut the Offset Cleat 4'-0" longer than the width of the Skylight or Chimney. Pancake Head Wood Screw 8243100 1" 1 Pancake Head Wood Screw every 6" of the Offset Cleat. Fasten through the Double Bead Tape Sealant. Double Bead Tape Sealant 6403899 25'-0"Apply to the panel before attaching the Offset Cleat. Tube Sealant 6403200 64032XX Apply under flat pan or cricket and at the corners of the penetration. C 4' 10'-2" © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1746 RESIDENTIAL DESIGN GUIDE Care and Maintenance Though factory applied pre-painted finishes are very durable and will last many years, eventually it may be desirable to thoroughly clean or repaint them. Dirt pickup may cause apparent discoloration of the paint when it has been exposed in some dirt laded atmospheres for long periods of time. In areas of strong sunlight, slight chalking may cause some change in appearance. A good clean- ing will often restore the appearance of these buildings and render repainting unnecessary. An occasional light cleaning will help maintain a good appearance. In many cases, simply washing the building with plain water using a hose or pressure sprayer will be adequate. In areas where heavy dirt deposits dull the surface, a cloth or soft bristle brush and solution of water and detergent (1/3 cup of laundry detergent per gallon of water for example) may be used. This should be followed by an adequate rinse of water. Do not use wire brushes, abrasives, or cleaning tools which will scratch the coating surface. Mildew may occur in areas subject to high humidity but is not normally a problem due to the high inherent mildew resis- tance of the baked finish that is used. However, mildew can grow on dirt and spore deposits in some cases. To remove mildew along with the dirt, the following solution is recommended. 1/3 cup detergent (Tide® or equivalent) 2/3 cup trisodium phosphate (Solex® or equivalent) 1 quart of 5% sodium hypochlorite solution (Clorox® or equivalent) 3 quarts of water Strong solvents and abrasive type cleaners should be avoided. Most organic solvents are flammable and toxic, and must be handled accordingly. When using a solvent, consult maintenance professionals and label instructions for proper handling and disposal of washings. If required, a mild solvent such as mineral spirits can be used to remove caulking compounds, oil, grease, tars, wax, and similar substances. Use a cloth dampened with mineral spirits and apply only to areas which are contaminated. Follow up the use of this mild solvent with detergent cleaning and rinsing. DO NOT USE A WIRE BRUSH USE MILD DETERGENT AND WATER FOR HEAVY DIRT DEPOSITS HOSE OR PRESSURE SPRAY FOR ADEQUATE CLEANING © Metal Sales Manufacturing Corporation / Subject to change without notice 4/17 47 RESIDENTIAL DESIGN GUIDE Notes © Metal Sales Manufacturing Corporation / Subject to change without notice 4/1748 RESIDENTIAL DESIGN GUIDE Notes FL 11560.2-R3 C2181-2 9.8.2017 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Aluminum Image II Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Nom. 0.032" thick 3004-H14 or 3105-H24 Alloy (ASTM B209). Deck Description: Min. 7/16" thick OSB, min. 15/32" thick Plywood or min. ¾" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the deck field and edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 22.5 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) 107.4 psf @ fastener spacing of 6" o.c. Fastener Pattern: #10-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of ¼". Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) ‘Uplift Resistance of Roof Assemblies’ & UL1897-98 ‘Uplift Tests for Roof Covering Systems’. Test Equivalency: The test procedures in UL 580-94 comply with test procedures prescribed in UL 580-06. The test procedures in UL 1897-98 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be FL 11560.2-R3 C2181-2 9.8.2017 Page 3 of 3 computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T209-11, Reporting Date 5/27/11 FY 2020 Permit Number Provider Service (2)Contact Phone #Permit Expiration Date (1)Advanced Disposal C&R Jessica Dempsey 904-566-8447 N/A 20-05 Realco Recycling C Jean Baker 904-757-7311 1/12/2021 20-03 Shapells, Inc.C Tammy Lachapelle 904-786-5503 11/14/2020 20-01 Republic Services C Dan Walsh 904-443-2021 9/4/2020 20-07 All American Roll Off C Stacie Wilkinson 904-515-8418 3/9/2021 20-06 WCA Waste Corporation C Jake Pack 1-800-535-9533 3/1/2021 20-02 Phillips Containers C Michael Phillips 904-246-1500 10/30/2020 20-04 Donovan Dumpsters C Kyle Donovan 904-241-3785 12/26/2020 (1) City's Franchise Service Provider (2) C - Construction & Demolition Debris R - Commercial Recycling City Approved Franchised Construction and Demolition Roll-Off and/or Commercial Recycling Service Providers Prepared by: Brittany Percell Prepared Date: 3/10/2020 File Location: O:\Finance\Franchise permits fees\Approved Franchise Permit and Fee Information