Loading...
1690 Atlantic Beach Dr ERES20-0090 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: URBACH JUDITH 1690 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: A1A SOLAR CONTRACTING INC 10418 NEW BERLIN 223 JACKSONVILLE FL 32226 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1710 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1690 ATLANTIC BEACH DR ELECTRICAL RESIDENTIAL 300 amps/240 volts/first phase - install 3 tesla chargers $500.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/10/2020 PERMIT NUMBER ERES20-0090 ISSUED: 7/10/2020 EXPIRES: 1/6/2021 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $94.00 2 of 2Issued Date: 7/10/2020 PERMIT NUMBER ERES20-0090 ISSUED: 7/10/2020 EXPIRES: 1/6/2021 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $94.00 ERES20-0090 Address: 1690 ATLANTIC BEACH DR APN: 169505 1710 $94.00 ELECTRICAL $90.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R12296 $94.00 Printed: Friday, July 10, 2020 1:48 PM Date Paid: Friday, July 10, 2020 Paid By: A1A SOLAR CONTRACTING INC Pay Method: CREDIT CARD 344207437 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R12296 Electrical Permit Application City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone : {904) 247 -5825 Ema i I : I u i I d i ng- De g! @ coa b. uS s ,:' **ALLlHfORMATlOlt r' .. : Hl6tftt6f{f.gD:Ifil: '' r.,GRJ\Y.15,,REQUIRED;,: PERMIT f: PROJECT VALUE $ JEA TNFORMATTON REQUTRED ON ArL pERMrrs: .:3&-arvrps 2$slotrs 'r,,1,,,, PHASE f,3 rurw sERVtcE:floverhead frUnderground ffiUnderground up Pole trSesidential (Main) Service: E0-1O0amps 8.01-150amps ECommercial (Main| Seruice: ffio-too amps Ehot-t5oamps il rerrrpoRARY PoLE:amps E senvrcE upGRADE: [-l amps ECT Service - amps E nrew FEEDER {ADDrnoNS, AccEssoRy srRucruREs, ETC.}: ffi1-00 amps Etsoamps fl2o0amps fi amps ffiT service amps E noorrtoNs, REMoDEts, REpAIRS, BUTLD-ours, AccEssoRY STRUCTURES, ETC: E orrr* ELE.TRT.AL PR'JECTS: flswimming pool[Sign Bmoke Detectors {Qty) flfransformers KVA [Motors I nne AIARM SYSTEM (Requires 3 sets of plans]: ffi nunatns/MrscEllANEgus: Conductor Type ElMulti-Family (Main) Seruice: ffi-tooamps Etot-lsoamps E151-2O0amps ffitst-zooamps Size frtst-zooamps FlI amps fl amps ffi-amps # of Meters flCT Service _ amps # of Unit Meters Outlets/Switches: Appliances: A/C Circuits: 0-30amps 0-30amps O-60amps Heat Circuits: # circuits @-kw Number of Lighting Outlets, lncluding Fixtures: 31-100amps 31-100amps 61-10Oamps 101-20Oamps 101-200amps HP Sd uraor"a ro/12/1e iermit becomes void if work does not commence within a six month period or work is suspended or abandonedTor six months. I hereby certifu that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Name:Phone Number: Electrical Company:p r, o,., Q..&{-,=\a {#, -3&t#{'.. lr Fax: Co. Address:city, J$ $mvlil!e:;.,state: 2,p,'.*',W:.?;,& License Holder:State Certification/Registration #: lt3 l ,,\75 Notarized Signrture of License before me this lL 0", ature of Notary Public ally Known OR [ ] Produced ldentification fiReplace Bur4t/Dqm Ebtr'"., \f\Sts\\Esafety lnspectioq Epa Qhapqe toU rsgFJrr.€:l sr$r#E [F lfiaAffi Ao$,#u, ;-i 6H :,: MYCOIMMISSION#FFSS15-,?bffiSt:' EXPiRES Mav 11,202c t407)398-0153 Flo.idaNor€ryServ@.com The of ldentification: in the State of Florida, County of Flut*ri Generation Panel Outdoor/Lockable PowerWall #1 PowerWall #2 PowerWall #3 Fused Disconnect ELECTRICAL SINGLE LINE – PowerWall + SunPower PV Installation PROJECT | Urbach 1690 Atlantic Beach Drive | Atlantic Beach, FL 32233 A1A Solar Contracting, Inc. PowerWall Gateway Elec Panel #2 Elec Panel #1 M (12) SunPower 360w AC Modules (12) SunPower 360w AC Modules SunPower Monitoring Gateway Existing PV System (8.6kW) - - - - - - - - - - - - - - - - - - - - - - - - #10 AWG #10 AWG #4/0 AWG (CE) #4/0 AWG (CE) TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, time-based control, and backup. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240 V Feed-In Type Split Phase Grid Frequency 60 Hz Total Energy1 14 kWh Usable Energy1 13.5 kWh Real Power, max continuous2 5 kW (charge and discharge) Real Power, peak (10 s, off-grid/backup)2 7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10 s, off-grid/backup)7.2 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor Range (full-rated power)+/– 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency1,3 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Optimum Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m <  40 dBA at 30°C (86°F) MECHANICAL SPECIFICATIONS Dimensions 1150 mm x 755 mm x 155 mm (45.3 in x 29.7 in x 6.1 in) Weight 125 kg (276 lbs) Mounting options Floor or wall mount 1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2 In Backup mode, grid charge power is limited to 3.3 kW. 3 AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) 155 mm (6.1 in) 1150 mm (45.3 in) 755 mm (29.7 in) TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS PARTIAL HOME BACKUP WHOLE HOME BACKUP Main panelSub panel Solar Home loads Solar inverter Utility meter GridBackup Gateway Powerwall Backup loads Optional NA - BACKUP - 2018-11-01 Utility meter GridBackup Gateway including service disconnect Main panel Solar Whole home backup Solar inverter Powerwall Optional