1660 Beach Ave Unit 5 RES20-0117 Replace Siding, Doors, WindowsOWNER:ADDRESS:CITY:STATE:ZIP:
Young Street Partners 1 Main St Jacksonville FL 32206
COMPANY:ADDRESS:CITY:STATE:ZIP:
OSSI CONTRACTING LLC 1112 3RD ST NEPTUNE BEACH FL 32266
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169576 0100 OCEAN GROVE UNIT 01
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1660 BEACH AVE UNIT #5 RESIDENTIAL ALTERATION
RESIDENTIAL
replace siding, doors, &
windows $38000.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $245.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $122.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.51
STATE DCA SURCHARGE 455-0000-208-0600 0 $3.68
TOTAL: $376.69
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 7/13/2020
PERMIT NUMBER
RES20-0117
ISSUED: 7/13/2020
EXPIRES: 1/9/2021
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
2 of 2Issued Date: 7/13/2020
PERMIT NUMBER
RES20-0117
ISSUED: 7/13/2020
EXPIRES: 1/9/2021
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $376.69
RES20-0117 Address: 1660 BEACH AVE UNIT #5 APN: 169576 0100 $376.69
BUILDING $245.00
BUILDING PERMIT 455-0000-322-1000 0 $245.00
BUILDING PLAN REVIEW $122.50
BUILDING PLAN CHECK 455-0000-322-1001 0 $122.50
STATE SURCHARGES $9.19
STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.51
STATE DCA SURCHARGE 455-0000-208-0600 0 $3.68
TOTAL FEES PAID BY RECEIPT: R12305 $376.69
Printed: Monday, July 13, 2020 10:13 AM
Date Paid: Monday, July 13, 2020
Paid By: OSSI CONTRACTING LLC
Pay Method: CREDIT CARD 343903012
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R12305
Building Permit Application
City of Atlantic Beach Building Department
800 Seminole Road, Atlantic Beach, FL 32233
Phone : (904) 247-5826 Email : Building -Dept@coab.us
Upda red 10/9/18
"All INFORMATION
HIGHLIGHTED IN GRAY
IS REQUIRED .
Job Address : _-+I-''''"'''" .... G'---=() __ B:.:::...IoIe;.:;,...::Jv~h.!..-.:..;t_(/....:8.:....-__ V~,......:I_tL......;S:::;:-;",,-,_ Permit Number: __________ _
Legal Des cription /5 -S=,l.. 04 -J )' .-8. q E . t.J loiS O[ ftw G.I JIIQ REIt _______ _
Va lu atio n of W o rk (Replacement Cost) $ :3 ~ Q ;) Heated/Cooled SF ><. Non-Heated/Co oled_---L>-= __ _
Class or Work : O N ew O Add l t lo ~1tera t ion ~ pair U Move "J Oemo O Pool )2'VNindow/Door
• Use of exist ing/proposed str uctu r e(s): D Commerci al O Res idential
• If an existing structure, is a fire sprinkler sy stem installed?: DYes lJNo
No
City ---\-I-.!..-'~"""'~:::-"~...L---;-=:-"-"=-fl
E-Mail .. L
Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) ___________________ _
Con t ra ctor I n f orm ation ., k
Name of Company 0 ¢a ,', It> I' Ii ;\ ~JI '" J L< l C Qualifying A en t -~ A" L L? c.J );
Address I, " 7(2 f) J Ie <-.!_* City_P;, '.I N ,;; ij" (~S tp t e f'L Zi p IL~ j; 6
Office Phone ,,'. (;> () '31'/ ;J Job Site Co n tact umber _---" ... ..,.·lr4F"'c';.:"'--"t.?'-'J::.JJ~, .-----r-----
State Cert ification/Registrati on II E-Mail ...JA.k~hj.;j.f k "~ I '.or? t-!a i' < !ll?!
Architect Name & Phone /I ------f"~-"---:-..._------------------------
Engineer's Name & Phone It _____ ----'.,.-::....;..:;-'-____________________ -,_+-__
Workers Compensation insurer )/( S OR Exempt 0 Expiration Date --"'-Jt+--I-.'-J;...L-
Application is hereby made to obtain a permit to do the work and instal lations as indicated. I ce rtify that no work or i sta lation has
commenced prior to the issuance of a permit and that all work will be performed to meet th e standards of all the laws regu lati ng
co nst r uctio n in th is juris d ict ion. I understand that a separa t e perm it mu st be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS , POOLS, FURNACES , BOILERS , HEATERS , TANKS , and AIR CONDIT IONERS, et c. NOTICE : In addition to the requirements of this
permit, there may be additional restrictions applicable to this property that may be found in the pub lic records of this county, and
there may be additional permits required from other governmental entities such as water management districts, state agencies, or
federa l agencies,
OWN ER'S AFF IDA VI T: I cer t ify tha t all t he forego ing info rmation is acc urate and th at all work wi ll be done in comp lian ce with all
appl ic able laws regul ating construction and l oning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ~l"l)\nORNEY BEFORE
RECORD~/~~t. ' '6 :..(61V1M ENCEMENT . / j ,
t ~'2 r')()'l c llly KrllH,vfl OR
I ; Prl)duu~d Identlf iLatlOn
Typ~ elf l,j(!ntiF icJ iiol1 :
Kenwyn Diego Harrilal
~ NOTARY PUBLIC
~STATE OF FLORIDA
• -<"'..~ Commt# GG291178
or4\! , ~ Expires 1/14/2023
Sign ed d n
r"-'
m to (or affi r m ed) b efore me this V avof
'J~ '1&1 , VJUJ , by /... I()r;.~r...
M Persn flrl ll y Kno w n OR
I I Pr',du(e d ide ntificatIOn
I'lp e 'Jf :de n tifi(~tjun : ____ _
Kenwyn Diego Harrilal
NOTARY PUBLIC
~ STATE OF FLORIDA
'-~~.~ Commt# GG291178
~~ Expires 1/14/2023
I
,
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED)
*Project Address : , (, & 0 [) e4.ut.. 6,; w,., ~ + S-Permit #: _______ _
*Owner/Project Name : 8~ /f:VI; g~'l A-
As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s) for
the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your
product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product
approval may be obtained at: www.floridabuilding.org.
Category/Subcategory Manufacturer Product Description Umitation of USe State. Local.
A. EXTERIOR DOORS
1. Swinging T"~ 1"'4-Tf V ) l'Y1~u 11. lIN.. ~'-oU • I'\&. J:fvt-a. k-S8-~/. '2-..-)
2. Sliding J
3. Sectional
4. Garage Roll-Up
5. Automatic
6. Other
B.WlNDOWS
1. Single hung Y I< {( "'il\~.AJ~ ~""r.L hoJI" f-.... ~£JJ slk h. '7tf'.5-. I --2. Horizontal slider IJ J
3. Casement
4. Double hung
5. Fixed
6. Awning
7. Pass-through
8. Projected
9. Mullion
10. Wind breaker
11. Dual action
12. Other
Page 1 of4 Updated 10/17/18
category/Subcategory Manufacturer Product Description Umitation of Use State # Local #
C~ PANEL WALL
1. Siding '-J~ tiY:Ja.{):t1 r-llkLoi t sf,;.w I. J;;L A. + L~/'T'2.3 ~
2. Soffits I
3. EIFS
4. Storefronts
s. Curtain walls
6. Wall louvers
7. Glass block
8. Membrane
9. Greenhouse
10. Synthetic stucco
11. Other
D. ROOFING PRODUCTS
1. Asphalt shingles
2. Underlayments I
3. Roofing fasteners
4. Nonstructural metal
roof
5. BUilt-up roofing
6. Modified bitumen
7. Single ply roofing
8. Roofing tiles
9 . Roofing insulation
10. Waterproofing
11. Wood shingles/shakes
12. Roofing slate
13. Liquid applied roofing
14. Cement-adhesive
coats
15. Roof tile adhesive
16. Spray applied
polyurethane roof
17. Other
Page 2 of 4 Updated 10/17/18
51712020
I
Date Validated
Date Pending FBC Approval
Date Approved
s _ ............ _ .. -f Prod ----
Florida Building Code Online
08/25/2017
08/28/2017
10/10/2017
FL # Model, Number or Name Description
13192.1 Cemplank Lap Siding fiber-cement lap siding
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL13192 R5 II CemP lank -Installation .p'df
Approved for use outside HVHZ: Yes FL13192 R5 II ER RIO -2683-17 Plank Wood Metal Frame.p'df
Impact Resistant: N/ A FL13192 R5 II ER RIO-2687-17 Plank Shing le to CMU.p'df
Design Pressure: N/ A FLl3192 R5 II ER RIO-2688-17 Plank WSP Sheathing .p'df
Other: For use in HVHZ install in accordance with NOA 17-FL13192 R5 II NOA 17-0406.06.p'df
0406.06 Verified By: Ronald I. Ogawa 24121
Created by Independent Third Party: No
Evaluation Reports
FL13192 R5 AE ER RlO -2683-17 Plank Wood Metal Frame.p'df
FL13192 R5 AE ER RlO-2687-17 Plank Shin gle to CMU.p'df
FL13192 R5 AE ER RIO -2688-17 Plank WSP Sheathing..:.p'df
FL13192 R5 AE NOA 17-0406.06.p'df
Created by Independent Third Party: Yes
r
13192.2 HardiePlank Lap Siding fiber-cement lap siding
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL13192 R5 II ER RIO-2683-17 Plank Wood Metal Frame.p'df
Approved for use outside HVHZ: Yes FL13192 R5 II ER RIO-2687-17 Plank Shing le to CMU.p'df
Impact Resistant: N/ A FLl3192 R5 II ER RIO-2688-17 Plank WSP Sheathing..:.p'df
Design Pressure: N/ A FLl3192 R5 II HardiePlank-Installation .p'df
Other: For use in HVHZ install in accordance with NOA 17-FL13192 R5 II NOA 17 -0406.06.p'df
0406.06 Verified By: Ronald I. Ogawa 24121
Created by Independent Third Party: No
Evaluation Reports
FL13192 R5 AE ER RIO-2683 -17 Plank Wood Metal Frame .p'df
FL13192 R5 AE ER RIO -2687-17 Plank Shing le to CMU.p'df
FL13192 R5 AE ER RIO-2688-17 Plank WSP Sheathing..:.p'df
FL13192 R5 AE NOA 17-0406.06.p'df
Created by Independent Third Party: Yes
I
13192.3 HardieShingle Individual Shingles fiber-cement individual cladding shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL13192 R5 II ER RIO-2685-17 Shingle Wood Metal
Approved for use outside HVHZ: Yes Frame.p'df
bttps:'iwww.lloridabuilding.org!prl pr_app_dtl .aspx?param:wGEVXQwtDqlsk%2bGn Uu47oqxmaHRltHnoSL 7Rnc9n l-lNP2iZim2vOrA %3d%3d
I
!
315
HardieShingle'h Siding
SINGLE FAMILY INSTALLATION REQUIREMENTS
EFFECTIVE OECEMBER 2019
IMPORTANT: FA ILURE TO FOLLOW JAMES HARDIE WRITIEN INSTALLATION INSTRUCTIONS AND COMPLY WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS, AFFECT
BUILDING ENVELOPE PERFORMANCE AND MAY AFFECT WARRANTY COVERAGE. FAILURE TO COMPLY WITH ALL HEALTH AND SAFETY REGULATIONS WHEN CUTIING AND INSTALLING
TH IS PRODUCT MAY RESULT IN PERSONAL INJURY. BEFORE INSTALILATION, CONFIRM YOU ARE USING THE CORRECT HARDIEZONE® PRODUCT INSTRUCTIONS BY VISI1lNG
HARDIEZONE .COM OR CALL 1-866-942-7343 (866-9-HARDIE)
STORAGE & HANDLING:
Store flat and keep dry and oovered prior to
installation, Installing siding wet or saturated may
resu~ in shrinkage at butt joints, Carry planks on
edge, Protect edges and corners from breakage.
James Hardie is not responsible for damage caused
by improper storage and
handling of the
product.
GENERAL REQUIREMENTS:
~ CUTTING INSTRUCTIONS
OUTDOORS
1 Position cutting station so that airllow blows dust away from the
INDOORS
00 NOT grind or a.Jt with a power saw indoors. Cut using shears (manual, pneumatic or
etectric) or the score and snap method, not recommended lor products thicker than 7/16 in, user an a others near the cutting area,
2, Cut using one of the following methods:
a, Best: Cirullar saw equipped with a Hardi eB lade® saw blade 1----------------------
and attached vacuum dust collection sys tem. Shears
(manual, pneumatic or electric) may also be lI sed, not
recommended for products thicker than 7/16 in.
b, Better: Circular saw eQllipped with a dust co llection feature
(e 9 Rum"' saw) and a HardieBlade saw blade
c. Good: Circular saw 8(1lipped with a HardleB lade saw blade.
DO NOT dry sweep du sl; use wel dusl suppression or vaulum to collecl dust.
For maximum dust reduc tion , James Hardie recommends using the "BesY' u~ting
practices. Alway s follow the equ ipmenl manufactllrer's instructions for prop er ope ration
For best perform ance when (lIlting with a circ ular saw, James Hardie recomm ends
using HardieBlade ' saw blades
Go to jame sha rdiepr os.com for additiona l cuttilg and dust control recommendatioos
IMPORTANT: The Occupational Safety and Heallh Administration (OSHA) r811J1ates workplace exposure 10 silica dust. For construction sites, OSHA has deemed
that cutting liber cement with a circular saw havilg a blade diameter less than 8 indles and connected to a commercia ll y available dust collection system per
manufaclurer's instru ctions results in exposlJ'es below the OSHA Permissible Exposure Limit (PE L) for respirable crystalline si li ca, without ltIe need for add itiona l
respiratory protection.
If you are unsure about how to cornply wrth OSHA silica dust regulations. consult a qualilied industrial hygi enist (J safety professional, or contact your James
Hardie technical sales represenlative for assistance . James Hardie makes no representation or warranty that adopting a particular ullting practice will assure
your compliance with OSHA rules or other app licable laws and safety requirements.
• HardieShingle panels can be installed over braced wood or steel studs, 20 gauge (33 mils) minimum to 16 gauge (54 mils) maximum, spaced a maximum
of 24 in o.c. or directly to minimum 7/16 in thick OSB sheathing. See General Fastening Requirements . Irregularities in framing and sheathing can mirror
through the finished application . Correct irregularities before installing siding.
• Information on installing James Hardie products over non-nailable substrates such as gypsum, foam. etc. can be located in JHTech Bulletin 19 at
www .jamehardie.com
• A water-resistive barrier is required in accordance with local building code requirements. The water-resistive barrier must be appropriately installed with
penetration and junction flashing in accordance with local building code requirements . James Hardie will assume no responsibility for water infiltration.
James Hardie does manufacture HardieWrap ® Weather Barrier, a non-woven non-perforated housewrap 1, which complies with building code requirements.
• When installing James Hardie® products all clearance details in figs. 1 thru 14 must be followed.
• Adjacent finished grade must slope away from the building in accordance with local building codes -typically a minimum of 6in in the first 10ft.
• Do not install James Hardie products, such that they may remain in contact with standing water.
• HardieShingle panels may be installed on vertical wall applications only,
• DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie\~1 Products .
• James Hardie Building Products provides installationlwind load information for buildings with a maximum mean roof height of 85 feet. For information on
installations above 60 feet, please contact JH technical support.
IFOI addltlwal Inlonnatlon on Har.JleWrap® WP.t1 lhtf Bal I1 er. I))05l.l Jam E'S Hardie 111 1-356-,IHard le or wvlWitard6\o\1'ap,(:(1(l1
(?B) JamesHardle-
STAGGERED EDGE PAtoEL I STRAIGHT EDGE PAtoEL I tlDMDUAl. SHINGLES I HALf..ROUNDS PANas
Visit Jamashardlepros.com lor the most recent version. HS11121 P1/8 12119
Trim
HARDIESHINGlE STAGGERED EDGE PANELS INSTAllATION Figure 22
Fastener Requirements
0.083 in x 0.187 in HD x 1 1/2 in long ringshank nails are used for fastening
HardieShingle'" Staggered Edge Panels to both framing and to 7/16 in thick APA
rated sheathing.
HardieShingle" Staggered Edge Panel Installation
Install HardieShingle® panels with joints butted in moderate contact. Due to
overlapping of the joints, caulk is not required except where panels abut trim
boards. (fig. 22 & 24). Ensure keyways do not line up on subsequent courses.
1) Install a 1-1/4 in starter strip, then install a 8-1/4 in wide
HardiePlank" lap siding starter course.
2) Place first panel so that panel end centers over stud. Trim panel as
needed. Butt the cut end into trim as shown (figs 22 & 24). When
installing over a band board or any horizontal surface, leave
1/4 in gap between bottom of siding and flashing.
3) Secure panel, leaving 1/8 in gap for caulk at trim and continue the course
along the wall.
4) Start the second course, by removing the equivalent of one full stud
cavity (16 in or 24 in OC), again abutting the cut end into the trim (figs 22 & 24).
This is to prevent pattern repetition. Repeat step 3.
5) Start the third course, by removing the equivalent of two full stud
cavities (figs 22 & 24) and repeat step 3.
6) Continue up the wall repeating steps 2 through 6 until desired height is reached.
Note: For aesthetic purposes you may trim
the bottom of the panel to create a straight
edge. If doing so, ensure all cuts ends are
properly sealed and painted (fig 23)
Figure 23::'--i~""'_"" __ ~
1/4 in gap. Do not caulk.
!land board
HARDIESHINGlE STAGGERED EDGE PANEl COVERAGE
15 7/B in
panels _J_
sacoild
course
position nails on nail line and secure into fmming . nly when
application is to minimum 7/16 in thick JlJ'A rated slleathing.
position nails on nail line spaced a maximum of 13 3/4 in o,c.
Allow 3/B in from panel edges .
Steps 5 & 6
1/8 in min. gap for caulk
HardleShingle~ Siding
sheathing
Panels for sidewall applications are available in 48 in lengths. Pieces needed for one square (1 OOsq.ft.) of product coverage = approximately 50. based on a
maximum 6 in exposure from the top edge of HardieShingle panels in subsequent courses (refer to Figure 13).
7 IN EXPOSURE HARDIESHINGlE STRAIGHT EDGE PANElS INSTALLATION (For 5 in exposure product please go to page 7)
Maximum Exposure of 7 in
REFER TO STAGGERED EDGE INSTRUCTIONS ABOVE
~
Tr im 1/8 in min. r-16 in or 24 i ~1
gap for o.c .
caulk
-r--
15-114"
panels __ L_
second
course
Figl1'e24
trim first panel BY. In
to hit center of HardiePlank" lap
furthest stud siding
-l--
15-~(.4 in
pa~IS
position nails on nail line and secure into lraming. Only when application is to minimum 7/16 in thick APA rated
sheathing. posilion nails on nail line spaced a maximum of 13 3/4 in 0 c. Allow 3/8 in Irom panel edges .
HARDIESHINGlE STRAIGHT EDGE PANEl COVERAGE
Panels for sidewall applications are available in 48 in lengths. Pieces needed for one square (1 OOsq.ft.) of product coverage = approximately 43, based on maximum 7 in exposure.
HSll121 P4/8 12119
HARDIESHINGLEINDIVIDUAL SHINGLE INSTALLATION
HardieShingle Individual Shingles must be installed with the widest part of the shingle
placed downwards and directly to minimum 7/16 in thick sheathing.
Fastener Requirements
0.091 in x 0.221 in HD x 1 1/2 in or 0.121 in x 0.371 in HD x 11/4 in long corrosion
resistant siding nails are used for fixing HaltlieShingle siding to 7/16 in thickAPA
rated sheathing.
HardieShingle Individual Shingle Installation
Due to overlapping of the joints, caulk is not required except where panels butt trim
boards. Space shingles a maximum 1/4 in apart and leave a minimum lap of 1 1/2 in
between successive courses (fig. 26).
1) Install 1 1/4 in starter strip and a 8114 in wide HardiePlank siding starter course.
2) Install first shingle from the end abutting trim. Install widest part of
shingle placed downwards. (fig. 25).
3) Secure shingle, leaving a 1/8 in gap for caulk at trim and continue the
course along the wall.
4) Start the second course, leaving a minimum lap of 1 1/2 in between
successive courses, again from the end abutting the trim. Repeat step 3.
5) Continue up the wall repeating steps 2 through 5 until desired height
is reached,
HARDIESHINGLE INDIVIDUAL SHINGLE COVERAGE
Individual Shingles for sidewall applications are available in assorted widths
as listed below. Bundles needed for one square (100 sq, ft.) of product coverage:
Shingle Number Pieces
Width of Bundles per Bundle
Flg~e25
Trim
-r--
15-1/4 In
·sh lngle _J __
Flg~e26
o
postion nails on nail line a
minimum of 3/8 in from edges
r--
15-114 in
HardleShingle" Siding
8114 in HardiePlank 1 y, in
lap sieling starter
strip
space
~-+--+-sl'ingles
max 1/4 in
apart
4-3/16 in 3 15
5-112 in 6 15
sl,ingle r ---
1 7 in max. Leave a min. lap
I'Ht-----_+__ of 1-1/2 in between expotsure joints in succesive
_____ '[ ___ -L-__ ~L-__ -' '-_-'L-___ ---" course
6-3/4 in 3 15
7-1/4 in 6 15
10 in 3 15
HARDIESHINGLE HALF-ROUND PANELS INSTALLATION
Fastener Requirements
0.083 in x 0.187 in HD x 1 112 in long ringshank nails are used for
fastening HardieShingle Half-Round Panels to both framing and to 7/16 in
thickAPA rated sheathing,
HardieShingle Half-Round Panel Installation
Install HardieShingle panels with joints butted in moderate contact. Due to
overlapping of the joints, caulk is not required except where panels abutt ttim
boards. (fig. 27). Ensure keyways do not line up on subsequent courses.
1) Install a 1-114 in starter strip, then install a 8-1/4 in wide HardiePlank lap
siding starter course.
2) Place first panel so that panel end centers over stud. Trim panel as needed.
Butt the cut end into trim as shown (figs 18). When installing over a band
board or any horizontal surface, leave 1/4 in gap between bottom of siding
and flashing.
1/8 gap
for
caulk
151/4 in
sl,ingles
1
3) Secure panel, leaving 1/8 in gap for caulk at trim and continue the course along
the wall.
A Install with the widest part of
the shingle placed downwards
4) Start the second course, by removing the equivalent of one full stud cavity (16 in
or 24 in DC), again abutting the cut end into the trim (fig 27). This is to prevent
pattern repetition. Repeat step 3.
CQrrect alignment
posiliOll nails Inlo Imming
through pr e'llous cou[res.
5) Start the third course, by removing the equivalent of two full stud cavities (figs
28 & 30) and repeat step 3.
6) Continue up the wall repeating steps 2 through 6 until desired height is reached,
HARDIESHINGLE HALF-ROUND PANEL COVERAGE
Only when applCa llo n Is to mUl1IHum
t Il 6 In thick ~A rated sheathing ,
position nails at 13 3/4 in o.c
Allow 3/8 in from panel edges
Panels for sidewall applications are available in 48 in lengths, Pieces needed for one square (100 sq. ft,) of product
coverage=43 pieces with 7 in exposure.
8-1/4 in HardiePlank
lap siding
HS11121 P5/8 12119
RES20-0117
RES20-0117