Loading...
920 Mayport Rd SIGN20-0007 Permit PacketFinal Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION OWNER:ADDRESS:CITY:STATE:ZIP: JACKREL TED 13707 LITTLE HARBOR CT JACKSONVILLE FL 32225-5424 COMPANY:ADDRESS:CITY:STATE:ZIP: SHARK SIGNS OF NE FL INC 5317 Shen Avenue Jacksonville FL 32205 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170772 0000 ATLANTIC BEACH SEC H JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 920 MAYPORT RD SIGN WALL WALL SIGNS $2140.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $125.00 FREE STANDING SIGN NO ELECTRIC 455-0000-322-1000 0 $0.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 0 $0.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 43.36 $185.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.63 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.75 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/15/2020 PERMIT NUMBER SIGN20-0007 ISSUED: 7/15/2020 EXPIRES: 1/11/2021 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $384.38 2 of 2Issued Date: 7/15/2020 PERMIT NUMBER SIGN20-0007 ISSUED: 7/15/2020 EXPIRES: 1/11/2021 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $384.38 SIGN20-0007 Address: 920 MAYPORT RD APN: 170772 0000 $384.38 BUILDING $250.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 43 $185.00 BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN REVIEW $125.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $125.00 STATE SURCHARGES $9.38 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.63 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.75 TOTAL FEES PAID BY RECEIPT: R12328 $384.38 Printed: Wednesday, July 15, 2020 1:14 PM Date Paid: Wednesday, July 15, 2020 Paid By: SHARK SIGNS OF NE FL INC Pay Method: CREDIT CARD 345335559 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R12328 SIGN20-0007 ELPP20-0020 Sign Allowance: Moto Electric Vehicles 920 Mayport Road Atlantic Beach, FL 32233 1:1 linear ft of unit W: 45.00’ 45.00 Sq Ft 43.36 Sq Ft chris@sharksignsofnefl.com E359831 Review layout thoroughly; errors or omissions are the responsibility of the client once layout has been approved and production initiated. Color appearances on layouts are subject to your computer monitor rendering capability; some colors may not appear as intended and some colors may vary. If s specific PMS, Pantone or other color is required rendering will be as close as possible. If a color match is required client MUST provide specific PMS color. Finished product is dependent on the quality of artwork provided by client. Rendering scaling is representative of finished product; please allow for minor size variances in production or fabrication. We do not reproduce trademarked, copyrighted or other proprietary logos or likenesses without proof of permission of reuse. ALL RENDERINGS & LAYOUTS ARE PROPERTY OF SHARK SIGNS OF NE FL., INC. NO REUSE OR REPRODUCTION WITH EXPRESSES PERMISSION. SIGNATURE REQUIRED Production/permitting cannot initiatewithout signed document N/A White with translucent vinyl overlays Black Raceway Color: Black H: 3.67’ x 8.00’ = 29.36 Sq Ft H: 1.00’ x 7.00’ = 7.00 Sq Ft H: 1.00’ x 7.00’ = 7.00 Sq Ft 8.00’ 45.00’ 4.00’ External Power Cut-Off Switch E359831 Front-Lit Wall Cabinet-Flush Mount GOLF CARTS PARTS SERVICE GOLF CARTS PARTS SERVICE1.00’4.00’ 7.00’ 1.00’ 7.00’ GOLF CARTSGOLF CARTS PARTS SERVICEPARTS SERVICE SIGN20-0007 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 ME #: 48579 (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision 464 N. Hiddenbrook Dr, Advance, NC 27006 Structural Sign Design&Engineering Ser vices Sheet #: 1 OF 4 Date: 6-10-2020 The electronic seal appearing on this document was authorized by Sean M. McFarland, PE on June 10, 2020.(48579) ABInitial Drawing: Client: City/State: Address: ATLANTIC BEACH, FL 920 MAYPORT RD SHARK SIGNS OF NE FL, INC MOTO ELECTRIC Ph: (281) 813-7439 Email: sean@signstructures.com Web: www.signstructures.com ENGINEERING OF ATTACHMENT TO WALL ONLY. NO CABINET ENGINEERING OR EVALUATION OF AS BUILT WALL CONDITIONS PROVIDED OR IMPLIED. ASCE 7-10, 130 mph Wind, Exposure C This design Complies with the High Velocity Hurricane Zone Code and with the 2017 FBC 6th ed. NC Firm Registration: F-1136 Florida License Number: 61049 Florida License Expires: Feb. 28, 2021 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 Connection Specifications - “GOLF CARTS” Attach Cabinet to Wall with Evenly Spaced Connectors. See Drawings for Complete Fabrication Specifications. Don't Overtighten Connectors. Use Oversized Washer Backers for Thru Wall Connectors. Embed Tapcons - 1 1/2" Min. into Solid Wall Kwik Bolts or HY-20 HAS Rods - 1 1/2" Min. Embed. into Solid Wall (or Hollow CMU w/ Screens) Liberty Bolts into Min 3/4" Plywood or Solid Wall Lags into 2X - Full Tip Penetration Thru Bolts Require Continuous 2X or Angle Backers CONNECTION QUANTITY 1 2 3 4 CABINET 1/4” TAPCONS 3/8” HY-20 6 5 6 8 3/8” LIBERTY BOLTS 8 3/8” LAGS (2X4) 6 3/8” THRU BOLTS 4 3/8” KWIK BOLTS 6 THRU BOLT EXTERIOR WALL WALL STRUCTURE STEEL ANGLE BACKER TYPICAL THRU BOLT CONNECTION 3”=1’-0” CABINET BACK TAPCON ANCHOR EXTERIOR MASONRY WALL TYPICAL ANCHOR BOLT CONNECTION 3”=1’-0” CABINET BACK EXPANSION ANCHOR BOLT (KWIK BOLT) EXTERIOR MASONRY WALL TYPICAL EXPANSION BOLT CONNECTION 3”=1’-0” CABINET BACK EXTERIOR MASONRY WALL TYPICAL CHEMICAL ANCHOR CONNECTION 3”=1’-0” CABINET BACK HILTI HY 20 EPOXY W/ HIT-A RODS. LAG BOLT EXTERIOR WALL WALL STRUCTURE TYPICAL LAG BOLT CONNECTION 3”=1’-0” CABINET BACK 2X BLOCKING LIBERTY BOLT EXTERIOR WALL WALL STRUCTURE TYPICAL LIBERTY BOLT CONNECTION 3”=1’-0” CABINET BACK ME #: 48579 (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision 464 N. Hiddenbrook Dr, Advance, NC 27006 Structural Sign Design&Engineering Ser vices Sheet #: 2 OF 4 Date: 6-10-2020 The electronic seal appearing on this document was authorized by Sean M. McFarland, PE on June 10, 2020.(48579) ABInitial Drawing: Client: City/State: Address: ATLANTIC BEACH, FL 920 MAYPORT RD SHARK SIGNS OF NE FL, INC MOTO ELECTRIC Ph: (281) 813-7439 Email: sean@signstructures.com Web: www.signstructures.com ENGINEERING OF ATTACHMENT TO WALL ONLY. NO CABINET ENGINEERING OR EVALUATION OF AS BUILT WALL CONDITIONS PROVIDED OR IMPLIED. ASCE 7-10, 130 mph Wind, Exposure C This design Complies with the High Velocity Hurricane Zone Code and with the 2017 FBC 6th ed. NC Firm Registration: F-1136 Florida License Number: 61049 Florida License Expires: Feb. 28, 2021 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 Connection Specifications - MAIN ID Attach Cabinet to Wall with Evenly Spaced Connectors. See Drawings for Complete Fabrication Specifications. Don't Overtighten Connectors. Use Oversized Washer Backers for Thru Wall Connectors. Embed Tapcons - 1 1/2" Min. into Solid Wall Kwik Bolts or HY-20 HAS Rods - 1 1/2" Min. Embed. into Solid Wall (or Hollow CMU w/ Screens) Liberty Bolts into Min 3/4" Plywood or Solid Wall Lags into 2X - Full Tip Penetration Thru Bolts Require Continuous 2X or Angle Backers CONNECTION QUANTITY 1 2 3 4 CABINET 3/8” TAPCONS 3/8” HY-20 8 5 6 12 3/8” LIBERTY BOLTS 8 3/8” LAGS (2X4) 8 3/8” THRU BOLTS 6 3/8” KWIK BOLTS 8 THRU BOLT EXTERIOR WALL WALL STRUCTURE STEEL ANGLE BACKER TYPICAL THRU BOLT CONNECTION 3”=1’-0” CABINET BACK TAPCON ANCHOR EXTERIOR MASONRY WALL TYPICAL ANCHOR BOLT CONNECTION 3”=1’-0” CABINET BACK EXPANSION ANCHOR BOLT (KWIK BOLT) EXTERIOR MASONRY WALL TYPICAL EXPANSION BOLT CONNECTION 3”=1’-0” CABINET BACK EXTERIOR MASONRY WALL TYPICAL CHEMICAL ANCHOR CONNECTION 3”=1’-0” CABINET BACK HILTI HY 20 EPOXY W/ HIT-A RODS. LAG BOLT EXTERIOR WALL WALL STRUCTURE TYPICAL LAG BOLT CONNECTION 3”=1’-0” CABINET BACK 2X BLOCKING LIBERTY BOLT EXTERIOR WALL WALL STRUCTURE TYPICAL LIBERTY BOLT CONNECTION 3”=1’-0” CABINET BACK ME #: 48579 (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision 464 N. Hiddenbrook Dr, Advance, NC 27006 Structural Sign Design&Engineering Ser vices Sheet #: 3 OF 4 Date: 6-10-2020 The electronic seal appearing on this document was authorized by Sean M. McFarland, PE on June 10, 2020.(48579) ABInitial Drawing: Client: City/State: Address: ATLANTIC BEACH, FL 920 MAYPORT RD SHARK SIGNS OF NE FL, INC MOTO ELECTRIC Ph: (281) 813-7439 Email: sean@signstructures.com Web: www.signstructures.com ENGINEERING OF ATTACHMENT TO WALL ONLY. NO CABINET ENGINEERING OR EVALUATION OF AS BUILT WALL CONDITIONS PROVIDED OR IMPLIED. ASCE 7-10, 130 mph Wind, Exposure C This design Complies with the High Velocity Hurricane Zone Code and with the 2017 FBC 6th ed. NC Firm Registration: F-1136 Florida License Number: 61049 Florida License Expires: Feb. 28, 2021 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595 Connection Specifications - “PARTS - SERVICE” Attach Cabinet to Wall with Evenly Spaced Connectors. See Drawings for Complete Fabrication Specifications. Don't Overtighten Connectors. Use Oversized Washer Backers for Thru Wall Connectors. THRU BOLT EXTERIOR WALL WALL STRUCTURE STEEL ANGLE BACKER TYPICAL THRU BOLT CONNECTION 3”=1’-0” CABINET BACK TAPCON ANCHOR EXTERIOR MASONRY WALL TYPICAL ANCHOR BOLT CONNECTION 3”=1’-0” CABINET BACK EXPANSION ANCHOR BOLT (KWIK BOLT) EXTERIOR MASONRY WALL TYPICAL EXPANSION BOLT CONNECTION 3”=1’-0” CABINET BACK EXTERIOR MASONRY WALL TYPICAL CHEMICAL ANCHOR CONNECTION 3”=1’-0” CABINET BACK HILTI HY 20 EPOXY W/ HIT-A RODS. LAG BOLT EXTERIOR WALL WALL STRUCTURE TYPICAL LAG BOLT CONNECTION 3”=1’-0” CABINET BACK 2X BLOCKING LIBERTY BOLT EXTERIOR WALL WALL STRUCTURE TYPICAL LIBERTY BOLT CONNECTION 3”=1’-0” CABINET BACK Embed Tapcons - 1 1/2" Min. into Solid Wall Kwik Bolts or HY-20 HAS Rods - 1 1/2" Min. Embed. into Solid Wall (or Hollow CMU w/ Screens) Liberty Bolts into Min 3/4" Plywood or Solid Wall Lags into 2X - Full Tip Penetration Thru Bolts Require Continuous 2X or Angle Backers CONNECTION QUANTITY 1 2 3 4 CABINET 1/4” TAPCONS 3/8” HY-20 6 5 6 8 3/8” LIBERTY BOLTS 8 3/8” LAGS (2X4) 6 3/8” THRU BOLTS 4 3/8” KWIK BOLTS 6 ME #: 48579 (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision (XXXX) ABRevision 464 N. Hiddenbrook Dr, Advance, NC 27006 Structural Sign Design&Engineering Ser vices Sheet #: 4 OF 4 Date: 6-10-2020 The electronic seal appearing on this document was authorized by Sean M. McFarland, PE on June 10, 2020.(48579) ABInitial Drawing: Client: City/State: Address: ATLANTIC BEACH, FL 920 MAYPORT RD SHARK SIGNS OF NE FL, INC MOTO ELECTRIC Ph: (281) 813-7439 Email: sean@signstructures.com Web: www.signstructures.com ENGINEERING OF ATTACHMENT TO WALL ONLY. NO CABINET ENGINEERING OR EVALUATION OF AS BUILT WALL CONDITIONS PROVIDED OR IMPLIED. ASCE 7-10, 130 mph Wind, Exposure C This design Complies with the High Velocity Hurricane Zone Code and with the 2017 FBC 6th ed. NC Firm Registration: F-1136 Florida License Number: 61049 Florida License Expires: Feb. 28, 2021 DocuSign Envelope ID: 91CB01FA-C990-42DB-8C77-A35BDCEE7595