Loading...
315 3rd St RESA20-0009 15 of 20 metal roof report_1Metal Roof Certification & Listing Program Certification Report 11030-004-KCI 145 Limekiln Road, Suite 100B Issue Dated: 6/19/2018 New Cumberland, PA 17070 Revision Date: 3/12/2019 www.keystonecerts.com Expiration Date: 6/19/2023 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Construction Specifications Institute (CSI) Category: Division: 07 00 00 – Thermal & Moisture Protection Section: 07 41 13 – Metal roof and wall panels 1.Program Licensee: 1st Coast Metal Roofing Supply 186 SR 207 East Palatka, FL 32131 386-325-0242 http://www.1stcoastmrs.com/ 2.Certified Roof Covering: 1st Coast Metal Roofing Supply’s Model Armour Loc 26 Ga. non-structural nailstrip standing seam metal roof and wall panels installed over plywood sheathing roof deck for use in new construction and re-roofing applications. 3.Scope of Certification: This Certification Report provides technical data substantiating that the use of the certified roof covering and the evaluated roof systems are in compliance with the following: •2017 Florida Building Code - Building, 6th Edition, Section 1504.3.2. •Florida Product Approval Rule 61G20-3. Properties Evaluated: •Wind Uplift Resistance This Certification Report was used to qualify Florida Product Approval FL 24397. 4.Evaluated Roof System Description: 4.1. Roof Covering: Armour Loc 26 Ga. metal roof and wall panels are cold roll-formed from minimum 26 gauge ASTM A792 Grade 50 steel sheet. The panels are aluminum-zinc alloy coated per ASTM A792 (AZ50), and shall be installed in accordance with the manufacturer’s instructions and this Certification Report. 4.2. Roof Deck: Armour Loc 26 Ga. metal roof and wall panels are certified for use over solid or closely- spaced, nominal 15/32” B-C 4 ply CDX plywood sheathing complying with 2017 Florida Building Code, Section 2303.1.5, with a minimum slope of 2% (1/4:12). 4.3. Anchorage: Armour Loc 26 Ga. metal roof and wall panels shall be fastened to the roof deck using ST Fastening System ST Clip Screws #12 x 1” pancake-head wood screws (or equivalent) through the nailstrip at ½” from each end, then spaced 4-3/4” OC as specified in Table 1 and illustrated in Appendix 1. Metal Roof Certification & Listing Program Certification Report 11030-004-KCI Page 2 of 4 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. 5. Installation Armour Loc 26 Ga. metal roof and wall panels in new construction applications shall be installed in accordance with the 2017 Florida Building Code Section 1507.4, the manufacturer’s published installation instructions and this Certification Report. Armour Loc 26 Ga. metal roof and wall panels in re- roofing applications shall be installed in accordance with the 2017 Florida Building Code Sections 1507.4 & 1511, the manufacturer’s published installation instructions and this Certification Report. The manufacturer’s installation instructions shall be made available at the time of installation. If there are differences between this report and the manufacturer’s installation instructions, this report shall take precedence. 6.Product Performance The performance of the Armour Loc 26 Ga. metal roof and wall panels described in this Certification Report has been determined in accordance with: •UL 580-06, Tests for Uplift Resistance of Roof Assemblies. As tested & reported by the following independent accredited laboratory: Laboratory Report Ref. Intertek I2151.03-450-44-R1 6.1. Wind Resistance The allowable design uplift pressures for Armour Loc 26 Ga. anchored as illustrated in Appendix 1, when tested in accordance with the referenced standards with an applied safety factor of 2.0 are found in Table 1. Table 1 Description Anchor Pattern Anchor Man’f & Model Max Design Uplift Pressure Over 15/32” 4 Ply Plywood At ½” From Each End and 4-3/4” O.C. ST Fastening System ST Clip Screws #12 x 1” 86.0 psf 7.Conditions of Use Armour Loc 26 Ga. metal roof and wall panels must be insulated against other materials or metals including concrete, lead, copper and treated lumber that contains corrosive materials. 8.Limitations of Use Armour Loc 26 Ga. metal roof and wall panels are not qualified for use in the High Velocity Hurricane Zone (HVHZ). Fire classification, shear diaphragm design, roof deck design & attachment to supporting members are not within the scope of this Certification Report. Roof support framing shall comply with 2017 Florida Building Code Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. Metal Roof Certification & Listing Program Certification Report 11030-004-KCI Page 3 of 4 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. 9.Licensed Manufacturing Facilities This Certification Report is applicable only to Armour Loc 26 Ga. nailstrip standing seam metal roof and wall panels manufactured at the following locations: 1st Coast Metal Roofing Supply 186 State Rd 207 East Palatka, Florida 32131 Each licensed facility is subject to periodic inspection by Keystone Certifications to verify conformance with Keystone Roof Covering Certification & Listing Program requirements. 10.Identification Armour Loc 26 Ga. metal roof and wall panels represented by this report shall be identified with Keystone Roof Covering Certification & Listing Program certification labeling illustrated below, to be applied to individual panels, packaging, invoicing or bills of lading: keystonecerts.com 11030-004-KCI Aaron Shultz Validations Manager Date: 2019.03.12 10:52:59 -04'00' Metal Roof Certification & Listing Program Certification Report 11030-004-KCI Page 4 of 4 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Appendix 1 Note: In all cases (new construction and re-roofing), the anchors shall fully penetrate the plywood roof deck. Metal Roof Certification & Listing Program Certification Report 11030-004-KCI 145 Limekiln Road, Suite 100B Issue Dated: 6/19/2018 New Cumberland, PA 17070 Revision Date: 3/12/2019 www.keystonecerts.com Expiration Date: 6/19/2023 Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Certificate Revisions Rev # Date Description 0 6/19/2018 Initial issuance. 1 3/12/2019 Updated Model name to include metal roof "and wall panels"