Loading...
1411 Hibiscus St FIRE18-0005 Fire Alarm •SrLyr %v CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 FIRE - ALARM MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: FIRE18-0005 Description: install fire & burglar alarm system Estimated Value: 4100 Issue Date: 8/29/2018 Expiration Date: 2/25/2019 PROPERTY ADDRESS: Address: 1411 HIBISCUS ST RE Number: 171072 0000 PROPERTY OWNER: Name: 1411 HIBISCUS ST LLC Address: 399 BEACH AVE ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: LIFE SAFETY DESIGNS INC Address: 3038 LENOX AVE DARRYL ELKSNIS JACKSONVILLE, FL 32254 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. YS.=1`Jjj�� City of Atlantic Beach APPLICATION NUMBER �S / Building Department (To be assigned by the Building Department.) � 800 Seminole Road n 1_ R ��''^^ ;-• .& V —O O� �,� s Atlantic Beach, Florida 32233-5445 {{�� I \ .� Phone(904)247-5826 • Fax(904)247-5845 i N'�01-0 E-mail: building-dept@coab.us Date routed: l City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: { U l bl S C-tit S 5 . Department review required Yes No Building Applicant: U �L &L((����c'L4N PitSt gv Planning &Zoning (('' i Tree Administrator Project: 1, 1\ S+C (I rl r L G1 �Glr In 4- b(,t.004V Public Works Public Utilities cacti-I A sq 54e11-) Public Safety dire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By L- 6- Florida Dept. of Environmental Protection (— Florida Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: T�Approved. ❑Denied. fNot applicable (Circle one.) Comments: BUILDING 1� Q ) PLANNING &ZONING Reviewed by: \_ Date: `�!16 )15' TREE ADMIN. Second Review: ['Approved as revised. Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: )i yl Ht bis 4,5 s -/ftc-I- PERMIT# F V.E-I cxc I't 1 1- p isupLs St - TO PowA as . JEA INFORMATION REQUIRED ON ALL PERMITS AMPS VOLTS PHASE VALUE OF WORK$ NEW SERVICE ❑ Overhead n Underground ❑T Underground up Pole ❑Residential(Main)Service 00-100 amps ❑101-150amps Li 151-200amps amps # of Meters ❑Commercial(Main) Service .:0-100 amps ❑101-150amps - 151-200amps amps CT Service amps Conductor Type Size Multi-Family(Main)Service ❑0-100 amps :101-150amps 151-200amps amps # of Unit Meters ❑Temporary Pole L amps SERVICE UPGRADE L amps - CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) 100 amps ❑150amps 7200amps amps OCT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS ❑Swimming Pool ❑ Sign ❑Smoke Detectors_Qty ❑Transformers KVA Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans) Qty 1 volts/amps /;6‘,/3-1015 VALUE OF WORK$ y'UU' U 6 REPAIRS/MISCELLANEOUS ❑Replace Burnt/Damaged// Meter Can ❑Safety Inspection [Panel Change 0O to UG C LI L sh.�/ (r,s'o w.tr S�ppIJeol r; z UFESAFETY DESIGNS W W W . L I F E S A F E T Y D E S I G N S . C O M SUBMITTAL DATA FOR AMSEC 1141 HIBISCUS STREET 1141 HIBISCUS STREET ATLANTIC BEACH, FLORIDA JOB No. 218193OFF10E COPY June 20,2018 Approved By Permit Desk ELECTRICAL CONTRACTOR: Building Department TABLE OF CONTENTS: City of Atlantic Beach, FL I FIRE ALARM MANUFACTURERS CATALOG DATA + DESCRIPTION MANUFACTURER PART# PAGE# a)COMBINATION BURGLAR/FIRE ALARM CONTROL PANEL HONEYWELL VISTA-32FB 1-4 b)ISOLATOR HONEYWELL ECP-ISO 5 c)8-ZONE EXPANDER HONEYWELL 4208U 6-9 b)REMOTE POWER SUPPLY HONEYWELL HPF602ULADA 10-11 b)MANUAL PULL STATION ADEMCO 5140MPS-1 12-13 c)PHOTOELECTRIC SMOKE DETECTOR SYSTEM SENSOR 2W-B 14-15 d)KEYPAD(FIRE) HONEYWELL 6160CR-2 16 e)KEYPAD(BURGLAR) HONEYWELL 6160 17 f)MOTION SENSOR HONEYWELL DT8035 18-21 g)WALL MOUNTED HORN/STROBE SYSTEM SENSOR P2RL 22-25 h)CEILING MOUNTED STROBE SYSTEM SENSOR SCRL 26-29 h)120VAC SURGE SUPPRESSOR DITEK DTK-120SRD 30 II BATTERY CALCULATION DATA a) HONEYWELL(VISTA-32FB)BURGLER/FIRE ALARM CONTROL PANEL 1) BATTERY CALCULATIONS 31-33 b) HONEYWELL(HPF602ULADA)REMOTE POWER SUPPLY 1) BATTERY CALCULATIONS 34 3038 LENOX AVE. • Jacksonville • Florida 32254 • 904-388-1700 • Fax 904-388-1718 FL - EF000B78 FL CONTRACTOR 1 - 13235500011993 GA - 1-V0004677 Honeywell VISTA-32FB COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ` k. Now UL864 9th Edition Approved Designed to integrate seamlessly with CCN, access control initiating devices, notification circuits, communication devices, and Honeywell's full range of fire and burglary components, keypads, RF receivers and relays are also supported. the new VISTA-32FB provides the ultimate protection of life The VISTA-32FB has been designed to mount quickly and property.The UL Listed commercial fire and burglary and easily. control panel supports up to two partitions and up to 32 zones/points using hardwired, wireless and V-Plea® addressable technologies.A diverse line of Honeywell FEATURES • Supports addressable V-flex access •Automatic smoke detector sensitivity • False alarm reduction features: control points using VistaKey maintenance testing -Exit error logic (One to Four doors) -Exit delay reset • Commercial Wireless Fire and - • Supports eight hardwired zones, Burglary Cross zoning -Call waiting defeat 24 V Plex addressable points/zones, • Notification Appliance Circuits(two): -Recent close report or 32 wireless points/zones -Programmable • Can control two separate areas -Individually silenceable • Supports commercial hardwired, addressable V-Plex polling loop (partitions)independently • Carbon monoxide(CO)zone support and wireless zones • Stores up to 512 events and can (Rev 5 and higher) accommodate 75 user codes • Listed to UL864 9th Edition(Rev 5 • Programmable on-board auxiliary and higher) • Easily programmed and maintained relay with newly upgraded Compass Downloader Software 1 of 34 VISTA-32FB Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Hardwired zones -Two-wire smoke detector • Up to four doors using VistaKey -Provides nine style B hardwired zone/group expansion module V-Plex Access Control zones adds two or four zones •Stored events for one call retrieval -EOLR supervised for Fire and UL -Eight zone-Class A and B •Communication burglary installations extender module -Panel operation during download -Supports N.O. or N.C. sensors -Eight zone-Class B extender -Individually assignable to one of module -Split/Dual Reporting Applications eight partitions -One zone supervised contact -Up to 16 two wire smoke detectors monitor module The VISTA-32FB control is well suited for a variety of applications as an each on zone one and two(32 total) • UL Listed wireless expansion integrated fire and burglary control. -Supports up to 32 wireless zones/ • Patented addressable V-Plex polling Some of the applications supported are: points using 5881 ENHC or loop technology medical and professional buildings, 5883H Receiver -Supports up to 24 two-wire V-Plex churches or synagogues, office zones/points -Supervised by control for buildings, schools, strip malls, -Global polling technology for check-in signals residences and factory or warehouse faster processing -Tamper protection for transmitters environments. -Supervised by panel -Individually assignable up to Installation -Individually assignable to partitions, eight partitions The VISTA-32FB alarm system has notification circuit(bell)output or -Supports wireless smoke detectors been designed to mount both quickly aux relay and easily. It meets all applicable • Event reporting requirements for UL commercial fire -4,000 ft.capability without the use • Local printer for access or and burglary installations. of shielded cable VISTA related event -Extender/Isolation bus modules 2 of 34 Honeywell SPECIFICATIONS Electrical Main Dialer Agency Listings • Primary power: 18VAC @ 72VA • Line seize: Double Pole • FCC Part 15, Class B; FCC Part 68 ADEMCO No. 1451 • Ringer equiv.: 0.7B • UL864/NFPA 72, Central Station and •Quiescent current draw: 300mA • Formats: ADEMCO Low Speed, Remote Station(Fire) • Backup battery: ADEMCO 4+2 Express, ADEMCO • UL609 Local Mercantile -12VDC, 7AH min to 34.4AH max High Speed, ADEMCO Contact ID, Premises/Mercantile Safe&Vault -Lead acid battery(gel type) Sescoa and Radionics • UL365 police station connected •Alarm power: 12VDC, 1.7A max for Cabinet dimensions burglar alarm each notification(bell)circuit output • 14.5" H X 12.5"W X 3" D • UL610 Central Station •Aux. standby pwr: 12VDC, 1 A max Burglar Alarm Environmental •Total power: 2.3A at 12VDC, . Storage temp: 14° F to 158° F • California State Fire Marshal 3.4A at 24VDC from all sources (-10°C to 70°C) • FM • 24 hours with 1A standby load •Operating temp: 32° F to 122°F • CAN/ULC S304-Central and Fusing (0°C to 50°C) Monitoring Station Burglar Alarm Unit • Battery input, aux. and notification • Humidity: 85% RH • CAN/ULC S527-Central Unit for (bell)circuit outputs are protected • EMI: Meets or exceeds the Fire Alarm Systems using PTC circuit protectors. All following requirements: • CAN/ULC S303-Local Burglar outputs are power limited. -FCC Part 15, Class B Device Alarm Unit -FCC Part 68 • CAN/ULC S525-Audible Signal -IEC EMC Directive Appliances 3 of 34 VISTA-32FB COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices • 4190WH AlarmNet Communicators • 4204-Relay Module, • 4193SN Two Zone Serial • 7545i-ENT-Internet/Intranet four form C contacts Interface Module Communicator • 4204CF-Two supervised •• 4208U Loop Expansion Module N 7845GSM-Digital Cellular output circuits -eight zones Communicator •5140DLM-Supervised Dialer •4208SNF Eight Zone/2 Class A/6 • 7845i-GSM-Internet and Digital • 5881 ENHC-RF Receiver Class B Expander Module Cellular Communicator •5883H-RF Receiver • 4293SN One Zone Serial Access Control •6160CR-2-Red Alpha Keypad Interface Module •VistaKey V Plex(addressable) • 6160-Burglary Keypad • 4297 Isolator/Extender Module Access Control •6220S-System printer used with •V-flex VSI Isolator Module •VistaKeySK Starter Kit 4100SM serial module V-Plex Smoke Detectors •VistaKey-EX Expansion Kit Two-Wire Smoke Detectors •5193SD Commercial Wireless Devices Conventional •5193SDT •5808W3-Photoelectronic • System Sensor V-Plex Passive Infrared Detectors Smoke/Heat Detector • ESL • 998MX • 5806W3-Photoelectric Smoke • DSC • IS2500SN Detector Horn/Strobes • DT7500SN • 5809-Wireless Heat Detector •System Sensor •QUEST2260SN • 5817CB-Wireless •Wheelock V-Plex Contacts Commercial Transmitter •Gentex •4194WH • 5869-Hold-Up Transmitter Manual Pull Stations • 4939SN-WH • 5881 ENHC-RF Receiver •5140MPS-1 • 4944SN-WH • 5883H-RF Receiver •5140MPS-2 •4959SN V-Plex(Addressable) Devices V-Plex Glassbreak Detectors • 4101 SN Relay Zone Module • FG1625SN • 4190SN Remote Point Module -two zones Product specifications subject to change. ORDERING VISTA-32FB Commercial Fire and Partitioned Burglary Alarm Platform V32FB-9 UL864 Rev 9 Version (Rev 5 and higher) Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 LNIST32FB/D October 2010 www.honeywell.com C 2010 Honeywell International Inc. 4 of 34 N ECP-ISO + v°ut 2 60ema ECP ISOLATOR ` J x c t vaut 1 seems _ GND Data In(Gm) E ca t 9 • [(� ') ... Data Out(Yel) THI t 5 o u • r p t V TRZI The ECP Isolator is designed to isolate burglary devices devices. It can also be used in any system to prevent from fire devices on the ECP bus, so that a trouble on the wire shorts or grounds from interfering with operation on burglary side of the bus will not affect the operation of fire another wired branch on the bus. FEATURES • Helps to maintain the operation of near-side isolated • Required for commercial fire alarm systems installed as equipment such as fire keypads and communicators in combination fire/burglary systems, or other high-security the event of shorts or grounds on the extended ECP bus. applications where isolation is required. SPECIFICATIONS Mounting: Power: V,°ui meal V,01(5001,) .Dousaa i • Mount inside the control panel 12VDC nominal BUNG AT GAD peck-) SAD enclosure DEVICES GlGreenl Temperature: - t Compatibility: le a al • 32° F to 122° F(0°C to 50°C) • VISTA-32FBP o a > • VISTA-128FBP Humidity: • VISTA-250FBP • 0-86% non-condensing • FA1670C • FA1700C Listings: PANEL KEW.PO"T 0 0 0 0 Product Dimensions: • Listed to UL864 9th Edition • 3" W X 2-3/4" H x 1" D Product specifications subject to change. nedn ORDERING GND(.) '°FIRE N I"ea.) OEVO IGE9 ECP-ISO ECP Isolator For more information:www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 L/ECPISOD/D September 2009 www.honeywell.com c 2009 Honeywell International Inc. 5 of 34 N8215V7 3/09 Rev. A ADEMCO 4208U Honeywell Universal V-Plex® Eight Zone Expander INSTALLATION AND SETUP GUIDE FEATURES Keep in mind that connections to the polling loop are always The ADEMCO 4208U is a V-Plex®eight-zone expander for use required,while power supply connections are optional. with ADEMCO controls that support V-Plex (polling loop) r� devices. Characteristics of this device include: ` • Can be optionally powered from the control panel aux. power supply to reduce the amount of current draw from the polling loop.NOTE:The 4208U cannot be used with an external power supply for commercial fire applications. �I -®rte a • Uniquely identifies 8 EOLR supervised zones(all zones use ��G� i7 10k resistors,supplied). ,,- • DIP Switches can be used to set zone numbers or serial 00 I numbers. When used in the serial number mode,each serial number I, --- 2.ENGAGE TOP WITH CLIP. 1.INSERT BOTTO1A TABS • $ in the selected group can be assigned to any zone number. Figure 1.Tamper Magnet Installation • Loops A & B can be programmed for fast (lOmsec) Compatibility with Honeywell FBII Control Panels response. • Tamper protected. When using this module with a Honeywell FBII XL4 control panel,it is necessary to cut the two wire jumpers as shown below 1.For all fire(NFPA)and UL Commercial Burglary in Figure 2 and set dip switch 6 to the"ON"position. installations,the 4208U must be tamper protected or When using this module with a Honeywell FBII Security Umounted in a tamper-protected cabinet. Dimensions control panel, it is necessary to cut the two wire L2.Refer to the control panel installation instructions for jumpers as shown below in Figure 3 and set dip switch 7 to the specific programming/installation requirements. "ON"position and dip switch 6 to the"OFF"position. 3.All circuits are supervised and power-limited. JUMPERS 2 AND DIP 4.Use only 14-22 AWG wire. CUT SWITCHES MOUNTING /\ 1. Power should be disconnected before proceeding. 2. Be sure to mount the 4208U before making any wiring 7\ connections. \, 0019 GN When mounted remotely,tamper protection is required. Holes ®® % 13 on the back of the module's housing permit it to be mounted horizontally or vertically. Wires can exit from the side or the Figure 2. Making Module Compatible with Honeywell FBII breakout on the back of the housing. To enable tamper XL4 Control Panels protection, set DIP Switch 8 to OFF and attach the tamper JUMPERS I DIP magnet (provided) (Figure 1) to the module inside cover. Be CUT' SNATCHES sure to enable the expansion zone tamper option at the control (program field*24 = 0). If the module's cover is removed, the ® magnet attached to the cover(positioned near the reed switch) `® will cause a tamper signal to be sent to the control for every active zone on the 4208U module. When the installation is complete, install the cover and affix the Serial Number and , �\ Zone Assignment Tables to the inside cover of the control. ®� When mounted inside the cabinet with the control, the 4208U Figure 3. Making Module Compatible with Honeywell FBII should be mounted horizontally and does not need tamper Security Dimensions Control Panels protection, provided the cabinet is supervised. Insert two DIP SWITCH SETTINGS screws into the raised metal tabs leaving the heads app. 1/8" exposed, and then hang the 4208U using the two slots on the Zone Assignment Mode: back. In the zone assignment mode,the DIP Switches on the 4208U are WIRING used to assign the unit to a group of 8 consecutive zones. These zone numbers,once designated for the 4208U,cannot be used for Cbead is required. Refer to the N6361 Installation For CE installations ADEMCO N6361 EMI suppression anything else,even if you don't use all 8. Follow the steps below E using Table 1 for DIP Switch settings. Instructions for wire routing instructions. Polling loop and protection loop wires can be brought in either Serial Number Mode: through the back or front of the unit by removing the In the serial number mode, the DIP Switches on the 4208U are knockouts. used to assign the unit to a group of 8 serial numbers. You can Use 22 gauge twisted pair wire for polling loop connections. All assign any serial number to any zone number (except hardwire protection loops use 10k EOL resistors(included). A maximum zone numbers of the control)and you do not lose zone numbers if resistance of 300 ohms is allowed on protection loops(excluding you dont use all eight loops on the 4208U. Follow steps below EOLR). See Figure 4 for all connections. using Table 2 for DIP Switch settings. 6 of 34 • 4208U - ON POSITION 1: SELECT RESPONSE TIME - TB2 FOR LOOPS A and B DIP Switches qo--(� �r�,�• (SHOWN ON=SLOW). GNOPTIONAL AUX. �_, �POSITIONS 2-5:SELECT THE 8 SENSOR POWER INPUT. DEVICE GROUP ADDRESS ® o--(,)12v SEE NOTE I. (SHOWN ON,ON,ON, C)--(1)- _, / OFF=2nd GROUP SELECTION). E TYPE(SHOWN _.�REED(TAMPER)SWITCH ��,�) (USE TWISTEDO POLLING PAIR)IR) y / POSITION 6: DEVON=1CSERIAL NUMBER MODE). �J � — (FBII XL4 PANELS SET SWITCH 6 TO ON). mss. POSITION 7: NORMALLY SET TO*OFF'UNLESS 1.IF USING AUXILIARY POWER ON COMMECRICAL OFF ON USED WITH FBII SECURITY TB1 FIRE/BURG COMBINATION SYSTEMS Ie.g.vISTA-12BFBPI,DO NOT CONNECTTNEDIMENSION PANELS 0®0 0®0 0®0 0 m®I 'LOOP GROUND ONTERMNAL 2 ILJJ ancwRY PQYER CAN ONLY BE USED IN ?. 8: SELECT TAMPER PROTECTION g BURGLAR(APPLICATIONS SIDE VIEW3 SETTING(SHOWN 2.FORCE INSTALLATIONS A N6363 EMI "OFF" ENABLED). SUPPRESSION BEAD IS REQUIRED10 �� EACH LOOPS MAX LOOPS:Ak 1Bk 1Ck 1Dk 10kE1Fk 10kG1Hk 300ohnANCE: AzasUsocvc Figure 5. DIP Switch Settings ohms,10k EOLR) Figure 4. Summary of Connections Note:For Commercial and Residential Fire installations,no Table 1. 4208U Zone Assignments more than one(1)wire per terminal may be connected. For"Zone Assignment"mode,DIP Switch position 6 must be off. When using this mode,program each zone's"Input Type"as"DIP Switch Polling Loop Device"(DP),where applicable. THIS SWITCH SETTING PRESETS THE LOOPS TO THESE ZONE NUMBERS DIP Switch Position Loop Designations (-'Means"off) 2 3 4 5 6 A BCD EF G H • On On On On - 1 2 3 4 5 6 7 8 On On On - - 9 10 11 12 13 14 15 16 On On - On - 17 18 19 20 21 22 23 24 N On On - - - 25 26 27 28 29 30 31 32 Q On - On On - 33 34 35 36 37 38 39 40 m On - On - - 41 42 43 44 45 46 47 48 z On - - On - 49 50 51 52 53 54 55 56 On - - - - 57 58 59 60 61 62 63 64 3 3 - On On On - 65 66 67 68 69 70 71 72 N - On On - - 73 74 75 76 77 78 79 80 - On - On - 81 82 83 84 85 86 87 88 - On - - - 89 90 91 92 93 94 95 96 - On On - 97 98 99 100 101 102 103 104 - - On - - 105 106 107 108 109 110 111 112 - - - On - 113 114 115 116 117 118 119 120 "' - - - - - 121 122 123 124 125 126 127 N/A *Do not select 1-8 for VISTA controls. **If 9-16 is selected for controls that have 9 hardwire zones.Loop A(Zone 9)will be inactive. ***Accommodates option"ONE 4208 IN USE"if referred to in control programming. NOTE: Consult the Control Panel Instructions to determine the valid zone numbers for that control panel. Table 2. 4208U Serial Number Assignments THIS SWITCH SETTING PRESETS THE LOOP TO THESE SERIAL NUMBERS DIP Switch Position ("-"Means"off") Loop Designation 2 3 4 5 6 LOOP A LOOP B LOOP C LOOP D LOOP E LOOP F LOOP G LOOP H ON ON ON ON ON 000-4116 000-4117 000-4118 000-4119 000-4124 000-4125 000-4126 000-4127 ON ON ON - ON 006-9908 006-9909 006-9910 006-9911 006-9916 006-9917 006-9918 006-9919 ON ON - ON ON 013-9812 013-9813 013-9814 013-9815 013-9820 013-9821 013-9822 013-9823 ON ON - - ON 020-9716 020-9717 020-9718 020-9719 020-9724 020-9725 020-9726 020-9727 ON - ON ON ON 027-9620 027-9621 027-9622 027-9623 027-9628 027-9629 027-9630 027-9631 ON - ON - ON 034-9524 034-9525 034-9526 034-9527 034-9532 034-9533 034-9534 034-9535 ON - - ON ON 041-9428 041-9429 041-9430 041-9431 041-9436 041-9437 041-9438 041-9439 ON - - - ON 048-9332 048-9333 048-9334 048-9335 048-9340 048-9341 048-9342 048-9343 - ON ON ON ON 055-9236 055-9237 055-9238 055-9239 055-9244 055-9245 055-9246 055-9247 - ON ON - ON 062-9140 062-9141 062-9142 062-9143 062-9148 062-9149 062-9150 062-9151 - ON - ON ON 069-9044 069-9045 069-9046 069-9047 069-9052 069-9053 069-9054 069-9055 - ON - - ON 076-8948 076-8949 076-8950 076-8951 076-8956 076-8957 076-8958 076-8959 - - ON ON ON 083-8852 083-8853 083-8854 083-8855 083-8860 083-8861 083-8862 083-8863 - - ON - ON 090-8756 090-8757 090-8758 090-8759 090-8764 090-8765 090-8766 090-8767 - - - ON ON 097-8660 097-8661 097-8662 097-8663 097-8668 097-8669 097-8670 097-8671 - - - - ON 104-8564 104-8565 104-8566 104-8567 104-8572 104-8573 104-8574 104-8575 -2- 7 of 34 4 Set the DIP switches on the 4208U as instructed below (see Polling Loop Device). Loops can be learned in any order and Figure 5): assigned to any legitimate zone number. 1. Select fast/slow response for loops A and B using DIP When prompted to learn the serial number for a particular Switch 1: Fast=OFF(10msec)Slow=ON(400msec). zone, you may either enter it manually through the keypad, 2. Select mode of operation (serial number or zone through COMPASS Downloader, or "learn" it by momentarily faulting(shorting)the terminals of that zone as required by the assignment mode) using DIP Switch 6: Serial Number =ON;Zone Assignment mode= use with control. If entering a serial number manually through the mode=Xpanels,DIP switch 6 must= set OFF.t (ForON. keypad, enter it and press"*" to advance to the next prompt, FBIwhich will ask you for the loop number. Entering a"1"for each 3. Select the group setting using DIP Switches 2,3,4,and 5. serial number entered. See Table 1 for zone assignments or Table 2 for serial If learning or entering a serial number,"Duplicate of Zone XX" number assignments. If using more than one 4208U, be sure to set each one to a different group setting. Duplicate of Zone XX" is displayed; another device with that same serial number is already in the system. In that case,use 4. DIP Switch 7: For use with FBII Security Dimension a different serial number group setting on the 4208U. panels, DIP Switch 7 must be set to ON. For all other panels set DIP Switch 7 to"OFF". If learning a serial number by faulting its associated loop,make sure that other V-Plex 5. Select the 4208U Tamper Protection setting using DIP A devices are not activated,as they may interfere Switch 8: Tamper Disabled=ON Tamper Enabled=OFF. with the device being learned. Tamper will report for every active zone on the 4208U module. VERIFICATION OF PROGRAMMING PROGRAMMING To verify proper programming, the following test should be When setting the 4208U to a group of zone numbers,each zone performed: must be programmed as follows: 1. Be sure to enable expansion zone tamper protection at the • On ADEMCO 4140XMP and earlier controls, these zones control(program field*24=0). must be programmed as Left Loop Polling Loop Zones. 2. Set DIP Switch 8 to OFF(tamper enabled). • On ADEMCO VISTA-40 and later controls, these zones 3. Replace the 4208U cover and clear the keypad of any must be programmed in the #93 Menu Mode Zone faulted zones. Programming as INPUT TYPE "7" -- DIP Switch type 4. Remove the 4208U's cover and verify(on the keypad)that polling device(DP). only the zones you designated for this 4208U are indicating When setting the 4208U to a group of serial numbers,each zone a check(or trouble)condition. must be programmed as INPUT TYPE"6"--SL(Serial Number Table 3. Current Draw Calculations Power Input Source Current Draw (Input Voltage: 8—11VDC) (All zones shorted) From Polling Loop From Control Panel Aux.Power Polling Loop Only 28.6 mA Polling Loop and Auxiliary 0.6 mA 28 mA Power Input SPECIFICATIONS Sensor Loop Response: Physical: Slow: 400 msec(all loops) Width: 6-7/16"(163mm) Fast: 10 msec(option for loops A and B) Height: 4-1/4"(108mm) Sensor Loop Current: Depth: 1-1/4"(32nun) (@ Polling loop input=8-11VDC,no external power input): Electrical: 0.52mA(normal) Polling loop input: 8—11 VDC 1.3mA(shorted) Current draw: 28.6mA max.Aux. Power and Polling loop (see Sensor Loop Max.Resistance: Table 3) Up to 300 ohms of wire resistance+ 10k EOLR. Power Input(optional):Burr.Applications Only Compliance: 12VDC @ 28mA(from control panel's auxiliary power) NFPA-72 Compliant NOTE: Do not use a remote power supply. For UL Listed Commercial Fire Usage: Use N.O.contacts. Style B,supervise these loops using Model#EOL 100 fire listed 10k EOLRs(purchased separately). For UL Listed Commercial Burglary Usage: Use N.O.or N.C.contacts. Supervise using EOLRs supplied. -3- 8 of 34 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA(IC)STATEMENTS This device complies with RSS210 of Industry Canada. Operation is subject to the following two conditions: (1)This device may not cause harmful interference,and(2)This device must accept any interference received,including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada. SEE THE CONTROL PANEL'S INSTALLATION INSTRUCTIONS FOR COMPLETE INFORMATION REGARDING THE LIMITATIONS OF THE ENTIRE SECURITY SYSTEM. For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa Honeywell 2 Corporate Center Drive,Suite 100 P.O.Box 9040, Melville, NY 11747 Copyright©2009 Honeywell International Inc. www.security.honeywell.com III I1IIIIIIIIIIIFIU1111111ill N8215V7 Rev.A 3/09 9 of 34 Honeywell HPF602ULADA a Fire Alarm Power Supplyi$ , z t2Lifil Description �� N The HPF602ULADA Fire Alarm Power Supply from Honeywell I ', it ;C ' Power Products offers the highest value among power sup- . .11:2-1'4,''1;72 ,,,,,,::',4'41, _ plies available today. It delivers 6.0 A of notification appliance -1..,; circuit power and built-in synchronization for appliances from `¢ # ,,f ,.71 ` System Sensor, Gentex, Wheelock, and Faraday. Our design represents the state-of-the-art in fire alarm supplies.Yet for all w v ars rfiniari?iarifiti its sophistication, it is an extremely cost-effective notification power supply. The HPF602ULADA is a 6.0 A notification power expander that provides its own AC power connection, battery charging circuit,and backup battery space,for use with fire and security controls. It is ideal for powering notification appliances t required by the Americans with Disabilities Act (ADA). It con- tains a builtin ANSI cadence pattern,which can upgrade older o control panels that lack cadence capability. Benefits • Extends and supports power for additional fire alarm -One unit can be connected to each notification circuit on devices. the control panel and still provide full supervision of the • Instantaneous switchover to standby battery (if equipped) notification circuits all the way to the control panel. when AC fails, maintaining power to all attached devices • Supervision for a variety of functions,including: without intervention. -Low AC power. • Strobe signal "passes through" allowing syncing of large -Low battery condition. systems. - • LED lights for quick and easy diagnosis, troubleshooting, Earth ground fault. and status indication. -Auxiliary output power limit condition. -EOL supervision trouble or power-limited condition at an Features output. • 6.0 A of notification power. -Form-C trouble relay. • 24 VDC filtered output voltage. Specifications • DIP switches for easy reconfiguration. • Power supply has advanced switch-mode design. AC input: 120 VAC at 2.0 A. • Four power limited notification outputs:two Class A,or four • Output: 24 VDC @ 6.0 A (6.0 A total from all notification • Class B,or one Class A and two Class B. • circuits and auxiliary circuit). • Additional continuous auxiliary output. Amps per output circuit:3.0 A. • 3.0 A per output circuit. • Current draw of unit on battery: 75 mA standby; 175 mA in alarm. • Two inputs,two Class B or two Class A. • Auxiliary power circuits:4. • Ground fault detector/indicator. • Output configuration options:2 Class A(Style Z),4 Class B • Independent trouble relay. (Style Y),or 1 Class A and 2 Class B. • AC loss delay option shuts off power to nonessential high- • Notification circuit output:20.4 to 27.3 VDC @ 3.0 A each. current accessories,such as magnetic door holders. • Inputs:2,with configuration 2 Class B or 2 Class A. • Built-in synchronization for appliances from System Sensor, . Input voltage range:9-32 VDC. Gentex,Wheelock and Faraday. • Stand-alone operation. • Battery charging capacity:33.0 AH. • Lightweight design adds to ease of installation and reduces Ambient temperature rating:32°F to 120°F(0°C to 49°C). • shipping costs. • Relative humidity:85%non-condensing maximum. • Operates with most polarized, UL-Listed notification • Indicator lights: AC Power On (green), Battery Trouble devices. (yellow), Ground Fault (yellow), Auxiliary Trouble (yellow), • Complies with UL 864,UL 1481,and NFPA 72. Output Troubles(1-4 yellow). • Built-in ANSI cadence pattern output capability. • Dimensions: 16.0" H x 12.25" W x 3.0" D (cm: 40.64 H x 30.88 W x 7.62 D). • Connection to local fire control: -May be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. 10 of 34 Listings • Listings and approvals below apply to the basic HPF602ULADA panel. In some cases, certain modules may not be listed by certain approval agencies,or listing may be in process.Consult factory for latest listing status. •UL Listed:file S6677 •CSFM:7300-1637 This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR Northford,CT 06472-1610 hpp_techsery@honeywell.com www.honeywellpower.com DH-1011:B May 2010 Madein the U.S.A. I® U.S.Registered Trademark 2010 Honeywell International Inc. MEM S11/11 Page of QUALITY SYSTEMS 11 of 34 6160CR-2C tt COMMERCIAL FIRE ALPHA KEYPAD UL864 REV 9 LISTED i'' IrhiEk, I I The 6160CR-2 is an addressable remote keypad intended is backlit only when a key is depressed*, or when the for use in commercial fire applications with Honeywell's system is in alarm or trouble condition. commercial fire control panels.The keys are continuously Note:The LCD may be programmed to remain on at all times(see panel backlit for convenience and easy visibility. The LCD display instructions for details). FEATURES • Four programmable • Seven Status LEDs • Large easy-to-read display function keys —Armed (Red) • Red removable door —Ready (Green) • Built-in sounder — Power(Green) • Physical — Fire Alarm (Red) 5.250"W x 7.437" H x 1.312" D —Silenced (Yellow) —Supervisory(Yellow) —Trouble (Yellow) SPECIFICATIONS Sounder Compatibility • High-quality speaker • Supports Control Panels Electrical —VISTA-32FB Rev 5 and higher —VISTA-128FBP Rev 4 and higher • 45mA standby 160mA in alarm (sounder, back light and —VISTA-250FBP Rev 4 and higher LED on) ULJCUL and residential Listed for commercial fire and burglary installations. To be employed with manufacturer's listed control units as indicated in the installation instructions. Product specifications subject to change. NORDERING 6160CR-2 Commercial Fire Alpha Keypad For more information:www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 U6160CR2D/D September 2009 www.honeywell.com a 2009 Honeywell International Inc. 12 of 34 6160 ALPHA DISPLAY KEYPAD ..1 WITH DOOR ATTACHED •- t . ft- l,�i iS _ if w. if WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to The oversized function keys are easily accessed even when use. The attractive white console blends with any decor and the keypad door is closed, and can be programmed for fire, features a contoured, removable door that conceals burglary, personal emergencies and other operations. Colored illuminated soft-touch keys.The 6160 also features a new self-adhesive labels are included. larger and brighter 32-character display with easy-to-read plain-English status messages. FEATURES • Large, easy-to-use keypad •Zones and system events displayed •System functions clearly labeled • Keys continuously backlit for greater in plain English • Functions performed by just entering visibility • No confusing blinking lights security code plus command •Speaker with audible beeps • Four programmable function keys •White with removable door blends to indicate: with any decor - System status - Entry/exit delay -Other alarm situations SPECIFICATIONS Physical Wiring Compatibility • 5-5/16"H x 7-3/8"W x 1-3/16"D • - (Black): Ground • Fully compatible with all (135mm x 190mm x 30mm) VISTA controls. • +(Red): +12 VDC(Aux. Power) Current • D1 (Green): "Data in"to control panel •Standby-40mA • DO(Yellow):"Data out"from •Activated Transmission-160mA control panel NORDERING 6160 Alpha Display Keypad Honeywell Security&Custom Electronics Honeywell Honeywell International Inc. t■ PO Box 9035 cco6oio Syosset, NY 11791 v6160/D September 2006 www.honeywell.com ©2006 Honeywell International Inc. 13 of 34 514OMPS-1 /514OMPS-2 ::: Manual Pull Stations -a ADEMCO COMMERCIAL SECURITY SOLUTIONS PRIMARY FEATURES • ADA COMPLIANT FIRE 0 FIRE • KEY TEST OR ALLEN RESET FIRE 0 FIRE • KEYED TO ADEMCO CONTROLS • STYLIZED HIGH TECH DESIGN • ALUMINUM DIE CAST HOUSING nnt:m:7,A • TERMINAL BLOCK OR WIRE LEADS ,nciLM-=�' • GOLD CONTACTS 11 ® ® 11 • UL LISTED 11 11 11 II 123 11 ME • GENERAL DESCRIPTION provide a neat and distinctive appearance. The housing Ademco's manual fire alarm stations are designed to is finished in red with white raised lettering and the T be non-code single action devices for use in UL listed bar" handle is white with raised red lettering for fire alarm applications. The attractive die-cast alu enhanced visibility. The units are adaptable to both sur- minum-alloy housing meets ADA pull requirements and face and semi flush mounting configurations. has been tested at Underwriter's Laboratory. • MOUNTING For ADA compliance, manual stations must be mount- SEMI-FLUSH MOUNT ed less than 48" above the floor for front wheelchair Most semi-flush mount installations can be attached to access and less than 54" above the floor for side wheelchair access. a standard single-gang switch box using two 6-32 screws inserted through the slots that are centered on A key reset feature on the 514OMPS-1 is designed for the unit's metal mounting plate. positive authorized resetting action. The key is designed to operate and match Ademco controls.The 5140MPS-1 SURFACE MOUNT utilizes a terminal block for secure terminations. The Use Ademco Backbox model number 514OMPS-BB for 5140MPS-2 is furnished with an Allen hex fitting and is surface mount installations. The Backbox has four pre- equipped with wire leads. drilled mounting holes of 0.187 inch diameter and con- Two alarm deterrent break tubes are supplied with each duit knockouts. Secure the Backbox to a wall with manual station; one tube is visible from the front, and screws of size 8 or smaller. After the Backbox is in the spare is stored in a compartment within the unit. place, attach the conduit. • OPERATION The housing is locked by using a key or Allen wrench lock. Unlock the housing by turning the key clockwise Pulling the handle down causes the manual stations to and swinging down the front of the housing to make latch in the down position and to close the normally the sheet metal mounting plate accessible. Mount the open switch. The handle is restored manually by using metal plate to the Backbox using the four 1/4" long, the key to unlock the station and pivot the station for- 8-32 screws (supplied). ward for resetting the pull handle to its normal posi- tion. The crush tube is then inserted in the cavity and • DIMENSIONS the station assembly is then locked in the normal 4.75" H x 3.12" W x 2" D upright position. • CONSTRUCTION The 514OMFS-1 and 514OMPS-2 manual stations are constructed of a durable die-cast aluminum-alloy and ADEMCO The Technology Leader 14 of 34 i7£40 • iapea-I ABolouyoal ail SO/Z- sdw/l o0wRad 1 -luau a 3e 'pele.iedo se 'papoaiep Afensut eq o3 se os -pawn sapaleuogeq s,Ja2wnnJapun ;iasT uoi puoo Jleo13ewoxne ileys uoga s pale-dodo uv eq !legs suoiieas lenueyy;-xoq Bue6-ai6uls pjepuels •SIO 4uoo oowapd e uo Bupunow yang-pee "xogiioee Buiyo ew pJepue3s Ile 34 days al-LL •(youeJM wally)Ae i uo Bulunow ade},ans,in4 aigers eqllegs suorjeas e asn A(q Idaoxe uoraeuadp A ue&aew3 asiq lenooe .sJa33a1 pas±e.i Lit suopms 943 Jo 4110.11 aye uo Jeadde us -awe paJolseJ eq zouueo uoraeJado tet.wou 1.e1p Ile4s 31j-J pJOM ayj;•Janco eye uo pepinoJd suorr os pau6isap eq pegs Ita41. -(goua.uu uaiid) Aa)l e tplArt -ondIsut BupeJado alglsu►Almelo.qv%Aope wnu!wnie Bursa3 BuuwoUe looi 3asa.aisel paleJado agn3 adA3 3seo alp ;o pa33n.13suoo eq pus%Jowls ienueyy -iieaaq,e apniou± pus papoo-uou aq liege(d-sdV110b 1,g) •apls 3o 3u04 'Zea}paapunq auo#o aoue3slp tunes V SdW0b1,g lapoyy uope1S WJepy anj 'snug/kJ SNOLLVOHHIO3dS ON11133N1ON3/11/1dr 1,.031SHOdV sieuluue4 E1013 11013 •!DAUM JO aomap aolnep 4.1111 auoz louaioMall of 01 e3inepsno lnaJd snou�aid of s9eel j ai M ` saell!WJaj Ma33s llnd Z-SdWOV LS l-Sh1101S WVHJ`dIO 9NIHIM ■ xoq)10e9 eoejan3 •88-SdYVOff69 spew aim pue 3sal laseH ua fd XBH uor3e3s lenueyu :0-SjWOb6S iiooIe IewwJal pue Ise].3esaa Aa>i uoi3e3S ienueini :j-SdYVObLS NOIldWtiO3Ni SNId3O1:1O ■ SYSTEM SENSOR j A 3 Photoelectric HIs g Smoke Detectors System Sensor i3'"series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles:installation ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,P boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base Intelligence.P detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Builtin remote maintenance signaling smoothing algorithms are standard with the P line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the P •Wide-angle,dual color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings GI) MEA MSFM cC\ us LISTED ® approved approved S911 3011446 7272-1653:152 290-01-E 2093 3180932 16 of 34 (jy Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number ,listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 25 percent-per-foot nominal as measured in the UL smoke box The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 85 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 MA maximum average;4-wire:50 MA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 0;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 63 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.596/ft nominal Input Terminals 14 to 22 AWG Mounting 31/-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM02009 System Sensor. 38250hioAvenue•St.Charles,IL60174 Product spec-Morasswbieamchange without noticeAsitsyscemsensoccomfor SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 current product information.ina"di'gthe latest version ofthis data sheet. A05-0318.007.6/09.07169 17 of 34 Honeywell IS3OOand DT8000 Series 1S3035, 1S3050, DT8035 AND DT8050 WIRED PIR AND DUAL TEC MOTION DL I ECTORS Designed with the installer in mind, these high performance optics,look down,cover and wall tamper,and selectable pet small form factor motion detectors offer a trouble-free,out of immunity.Leading edge sensing technologies and a wide the box experience to simplify the install process and reduce range of models to suit the requirements of most applications, install time.With the passive infrared IS3035 and IS3050 and Honeywell's family of I53000 and DT8000 motion detectors DUAL TEC DT8035 and 018050.optimum performance is will maximize intruder detection while diminishing false alarms. achieved using custom developed extended range Fresnel FEATURES •Sleek,Sturdy Housing •Wall-to-Wall Coverage •Selectable Look Down The sleek,sturdy housing blends‘wen Wide and tong detection coverage with Provides better coveiage up close with any residential or commercial interior look•down zone for coverage range multiple zones in the look-down area. and is constructed of ABS plastic for protection that exceeds similar products Look down is switch selectable. superior shock and linpact protection. in the market. •PIR White Light Immunity It contains a convenient wiring channel, knockouts for mounting and wring •Advanced DualCore Signal A patented black bug guard reduces , arid easy access to terminals.Mounting Processing(DUAL TEC) false alarms by providing 6.500 lux of screws are located in the rear cover— DualCore signal processing white light immunity.This helps reduce enabling s analyzes P1R and microwave false alarm problems caused by lights. eaier:nstallat:on. signals through the microcontroller, flashlights or reflective oblects. •Sealed Optics and Electronics It supports a multitude of advanced • The optics and electronics are functions,including concurrent Flashlight Walk Test assembled into the front enclosure and diagnostics,digital fluorescent Reduces installation time as the sealed with a protective cover to prevent light interference filter,digital walk test can be enabled by simply t damage during installation.The sealed adaptive microwave thresholdwaving a flasnlighat the detector, , Auly optical chamber also prevents drafts adaptive baselines and bidirectional tomaticaItimes out. and insects teen affecting the detector. temperature compensation. •Flexible Mountings The IS3000 arid DT8000 motion •Integrated Screw Retention Features • Superior Detection and i To mount the detector on the wail, False Alarm Immunity detectors mount on walls or n corners, ' "- the installer will insert the screw in the The 5300)and 018000 detectors with heionts from 6 9 89 integrated mounting feature where it will provide superior protection against (2,1 m 2.7 mi.The IS3000 and family works with the SMB10 be automatically held in place,making false alarms without sacrificing mounting tne detector easy and quick. catch performance, family of swivel brackets, •Uniform Sensitivity Optics • Pet-friendly Selectivity The custom designed Fresnel lens installers can turn pet immunity on or provides the same sensitivity for human off with the flip of a DIP switch.When targets at the edge of the pattern as pet immunity is enabled, the detector exists directly in front of the detector, can distinguish between signals giving these detectors consistent caused by humans and signals caused coverage throughout Me protected area. by pets up to lefts. Shoiter precision focal lengths mean superior optics arid detection. 18 of 34 1S3000 and DT8000 Series IS3035 AND DT8035 WIRED PIR AND DUAL TEC MOTION DE I ECTORS Specifications 1S3035(PIR) DT8035(DUAL TEC) Range 9,0-15 WC,11 rnA typical,13 mA maximum; 9,0-15 VDC: 15 rh.A.typocal, 17 mA maxrnum; Power AG Ripple;3 V pea(oto-peak at nominal 12 VDC AC Rpole.3 V peak-to-peak at norninai 12 VDC Energized Form A;30 mA.25 VDC Energized Form A;30;TA,25 VDC, Alarm Relay 22 Ohms resiF,tanoe rnavmton, 22 Ohms resistance inwornum, Aladin Relay Durahun 3 seconds, Alamo Relay Duration-3 seconds Tampers Cover&Viall;(NC with cover installed)Form A, Cover&Wall;(NC vvitn cover installed)Form A; pe 30 rnA,25 VDC 30 mA,25 VDC Microwave Frequency - Ii RF1 Immunity 20Wrn 10-1000 MHz, 15Wm 1000-2700 MHz 20Virn 10-1(X)0 MHz, 15V,fr 1C00'2700 MHz PIR White Light Immunity , . ,• ,., Fluorescent Light Filter - 1 50 Hi./60 Hz Operating Temperature I : 1-t,: 1 i' , -I..(..;' 1'. 1,z 1 ,:. • Relative Humidity 5 to 93%;non-condensr,g 5 to 93%;non-condensing Temperature Compensation Ar.,;,.;,;;1....;:,;; Sq.;+, ;;;,;,;.r 3,86"H x 2.24 W11'DI 3.86°H x224"Wx 1.71*Di Dimensions 9,8 crn H x 5,7 cm W x 4.35 cm D 9,8 cm H x 5 7 crn W x.4 35 cm D Weight ,- 'P,: ,`, Pet Immunity s 801bs136kg --,100 ts;45kg IS3035/DT8035 DETECTION PATTERNS 33ft Top View (loo) Side View 27ft (8m) 7ft 13ft 20ft 27ft 33ft 40ft 20ft 7.5ft (2m (4m) (Cm)Arni(1 Om)(12rn) i6m) (nm) (0m) lir -view- 7ft _4_,....... . PLAN VIEW (2m) 4:_..., •••••0100011.11111 ,,,___........... . 1 ALL ZONES .4 -- ------- pm) .,..-,,,,,,,,-,....---.......„,0,,,mmui=imeimmi! ift Zones (2m) - 13ft A 2 Look-down T. *::4711.441.,%***:. ; (am) 20ft B 18 Lower (6m) 27ft (Sm) C 46 Intermediate _ 3311 (10r1-)Oft 7ft 13ft 20ft 278 33ft 4Qft D 36 Long (Cm) (2m) (4m) (6m) (8m)(10mX12m) 19 of 34 1S3000 and DT8000 Series 183050 AND DT8050 WIRED PIR AND DUAL TEC MOTION DL I ECTORS Specifications IS3050(PIR) DT8050(DUAL TEC) Range i ".",s. 7. 1 i, 1 ,..:;' `. ---.- 90-15 VOC,11 mA typical.13 rnA rraximurn; 90-15 WC:15 mA twical.17 mA maximum: Power AC Rople:3V peak-(o-peak at normal 12VDC AC Rpole:3 V peak-to-pea*at nominal¶2 VDC ! Energized Form A 30 mA,25 VDC. Energized Form A 30 rnA.25 VDC. Alarm Relay 22 Ohms resistance maximum. 22 Ohms resistance maximum Alarm Relay Duration:3 seconds Alarm Relay Duration:3 seconds Cover&Wall:(NC with cover installed()Form A. Covei&Wall.(NC witi cover installed)F0011 A: Tampers 30 rnA 25 VDC 30 m.A.25 VDC I Microwave Frequency RFI Immunity 20V.m 10-100C)MHz. 15Vim 1000-270n MHz 20Virn 10-1(X)0 MHz.15Vim 1000-2700 MHz PIR White Light Immunity ! i ' . .. ... _ — Fluorescent Light Filter 50 H7:60 Hi Operating Temperature H + i ' ,1 ,- -1 ,,, . ......, Relative Humidity 5 to 93%;non-condonsing 5 to 93%:non-condensog - — Temperature Compensation ; .:'..,.,, tr,_•,.1...„i.il S.,-.I...(.. 3.86"H x 2.24"W x 1,71"II' 3,86"H x2.24°W x 17Y 3 Dimensions 9.5 cm H x5.7 cm W x 4.35 cm ID 9.8 ern H x57 cm W x 435 cm 0 ! Weight 3,),,,,65 g ok.,1.4egiv, 3.6 oz;1 02 u(not we.gli:, iS3050/DT8050 DETECTION PATTERNS daft Top View 12 m Side View 331t la m ; 7ft 13ft 20ft 27ft 33ft 405 4711 53ft 27ft 7,511 (2m) (4m) (6m) (8m)(10rn)(12m)(14m)(1610) Sm (2 3m) ,., ..., 6 m "00,000- 00 i ''''''"!*•.,. .,, .., ._-"-"---,.......: Oft . - 1 13tt t'r 00000 .., j .00,00.00008° 4 m „.7.00000000000,10 ! B C D A PLAN VIEW ....... . 1", ALL ZONES ..7-....-..-7--.-- <,:.-.. ."""'''' ..,„,..... ....a.." Tft \...... _ 'N., Vftdiy, 13ft , Zones , A 2 Look-down 27ft B 18 Lower 8 m 33ft 10 m C 20 Intermediate daft 12 m 0 itt 1311 20ft 2711 33ft 4011 465 5311 D 54 Long 2m 4m 6m ern 10,112m14 mlern 20 of 34 1S3000 and DT8000 Series 183035, 183050, DT8035 AND DT8050 WIRED PIR AND DUAL TEC MOTION DE I ECTORS APPROVAL LISTINGS •UL 639 •ULC S306-03 •SIA PIP-01-2000 •FCC part 15,Class B verified • IC ICES-003.Class B verified ORDERING IS3035 PIR Motion Detector,35 foot IS3050 PIR Motion Detector, 50 foot DT8035 DUAL TEC Motion Detector, 35 foot DT8050 DUAL TEC Motion Detector, 50 foot Accessories" SM810 Swivel Mount Bracket(0,000-110-01) SM810C Swivel Mount Ceiling Bracket(0-0000-111,01) SMB1OT Swivel Mount Bracket with Tamper(0-000-155-01) DT8G2LENS5PK Replacement Fresnel Lens Kit -5 Pack 2103 Riser Rated Cable. Solid 22 AWG, 4 Conductor 3103 Plenum Rated Cable. Solid 22 AWG, 4 Conductor Note: Honeywell reserves the right to aler the specification of products without prior notice. 'Accessories not evaluated by UL. For more information: www hone,ywell.corn/sect Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr, Suite 100 Honeywell P0. Box 9040 Melville.NY 11747 1 600 467,5675 ifis3o7KmaG SerAertwir:CP A www.honeywellwn ea Hnnevwk4 21 of 34 T SYSTEM � SENSOR`: : t 1.1.1.1. 1 I1l11 Indoor Selectable- Output Horns, 1 Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification y products are rich with features guaranteed to cut -_ installation times and maximize profits with lower ell �,. 1 — current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L•Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING ,,- UL ® (c)--„) ) LISTED APPROVED 55512 FM approved except 7125-16539504 04011 for ALERT models 7135-16530503 3057383.3057072 22 of 34 • L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PhysicaUElectrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(Including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. 23 of 34 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on the 2-wire horn strobes. 24 of 34 L-Series Dimensions - _ = 1.91 = 3.46 = 1.25 3.46 1.25 r--.:4:41Ke.:: I101 fIlli wne�hnt,_l111It%:' itlettla';III o°o°ogo�o°o' 000.101i1. 0000O0 5.27 /i' 5.27 doo0 oQoo0.. VIII aa-, reI." y•. .irr r ail J_.t. I til ,. =.oJ til Compact Strobe/Horn Strobe Compact Horn 4.70 —E.- 1.91 = 4.70 = 1.25 _= 1.25 _,..._ /3 : ..4.z7 : ,. 5.67 ...>� 67 :.:3 iiddd" 1..., LI lik%.,... 16.1%.__,,..7.1;....„:.4 ..) 44M� Strobe/Horn Strobe Horn \\I L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT"marking on cover 0----_ $}# 7'EM 3825 Ohio Avenue•St.Charles,IL 60174 ®2017 System Sensor. ✓ •7 Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without nolice.Visit systemsensor.com � SENSOR* www.systemsensor.com for current product infoma VDSB S003 03117st version�����sheet. 25 of 34 • SYSTEM „.„ SENSOR , Indoor Selectable- frol Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower 01, current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNAUNG APP® LISTED 55512 FM approved except 7125-16539504 S4011 for ALERT models 7135-16539503 3057363 26 of 34 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit" Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86SOO 27 of 34 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 75cd 30cd 75cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 75cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86600 28 of 34 L-Series Dimensions - 2.47 1.37 = 0 6.92 ® 2.50 06.83 77.40 iiij 1 1 C gao ®g _ Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Al4 co _ 4 1 n 0 „Nor Nik ;,-.\(ki,0 4 ;fit``,',. Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White SYSTEM 02017 System Sensor. `` 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensorcom .y' SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product inforrnatbn,including the latestversion of this data sheet. AVDS86801•03/17 29 of 34 4 1„,,,in --', -120SR, a , �. �, ,0 :1 Pc. with Dry Contacts -:� x y,. DlTEK B�"° DITEK's DTK-I20SRD protects dedicated 120VAC ► - power circuits that feed control panels and other critical 0. -t equipment. The hybrid series design provides maximum ' 4� AP: critical load protection, and includes dry contacts for remote notification of surge protection status. EMI/RFI filtering ensures clean power for connected equipment. Technical Specifications Service Voltage: 120VAC Single Phase Product Features MCOV: 150VAC • Series design for fast response and best protection Protection Modes: All modes—L-G, L-N,N-G • Compact design fits in a variety of control Voltage Protection Rating: 600VAC panels • Suitable for use on circuit breakers rated at Surge Current Rating: 54,000 Amps per phase 10kA AIC Max.Continuous Current: 20 Amps • Multi-stage hybrid circuit design SCCR: 10kA ■ UL1283 EMI/RFI filtering Nominal Discharge Current 3kA • LED indicates protection status Rating (In): ■ Form C Dry Contact circuit Operation Frequency: 40Hz—400Hz EMI/RFI Filtering Attenuation: Up to 35dB, 100kHz-100MHz Application Mechanical Characteristics ■ Fire Alarm Panels Connection Method: Hardwired, series configuration • Control Panels Housing: ABS ■ 120VAC Single Phase Critical Loads Operating Temperature: -40°F-185°F(-40°C-85°C) • UL Listed Control Panels where UL Recognized Maximum Humidity: 95%non-condensing Components are Required Dimensions: 6.87"L x 3.5W x 2.5"H ___-____._._______._._ ..____..-_______ ___ (174050mm x88.90mmx63.50mm) Accessories Weight: 12.16 oz(0.35kg) • DIN Rail Mounting Kit—Part Number DTK-DRK Quality, Standards &Approval Agency Approvals: UL1449, cUL, UL1283 SPD Type: Type 2 Component Assembly Standards Compliance: IEEE C62.41.1 —2, IEEE C62.45 Warranty: Ten Year Limited Warranty Every precaution has been taken to ensure that this literature is accurate and complete.DITEK Corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information or for any errors or omissions. One DITEK Center 1720 Starkey Road-Largo,FL 33771 Doc.Number:SPS-100007-005 Rev 3 03/16 MADE IN Phone:1-800-753-2345 Direct:727-812-5000 ©2016 DITEK Corp. Tnlu Technical Support 1-888-472-6100 Page 1 of 1 ClUS NFP'O' www.ditekcorp.com u. G. A. 30 of 34 Battery Honeywell Security Conri prey Facility Information Enter Standby and Alarm Times Location: 1141 HIBISCUS STREET Battery Standby(hours): 24 — 2201020i1 lm�ucrhy z�'Er,Alr ,5 nr=�� Account 2181939 Alarm Duration(minutes): 5 ni Apply lit Rower Errnrts''(Requiree to ma;otaie IALisdn9�rdud,n9 Model: HONEYWELL VISTA 32FB 516841 Engineer: Recommended ❑cnrnmerou fire triFialialson 13.1 Date: 6/20/2018 Battery(AH) 0Canmeroel Burg I,dalab0vl SELECTED PANEL MAXIMUM OUTPUT RATINGS Polling Standby Alar Auxiliary Panel PMA Bell#1 Bell a2 Maximum Panel Maximum Panel 'Max Benny Auxiliary Standby Output Output lit Supported y Select Panel from pulldown list: Loop Power(nW Power(mA) (ma Alarm(mA) (mA) etd.mN Standby output Alarm Output su Pannee/db 128 1000 1700 300 470 1700 1700 1300 2800 34.4 I Total Standby :total Alarm Calculated Current Draw 27 3 135 440 Calculated Belt Draw 01 0 162 Standby Budget Alarm Budget Power Budget 660.0 Bell Power Budget 1700 1,,I _ 1137 7 _ - ❑Remove Unused Cees,Ran 2s External Bell Power Req'd(mA): Eat.UL Power Req'd(mA). Greyed-out devices)are not supported by selected panel How many moral Enter powered Standby,u,-x Alum TCL>I Polling Stanway Total Ertemal KEYPADS INTERFACES Quantify ernnedy? pn,r Curren,(Aur) Palling Loop Loop Current Total Alar Current Current Regimen 0 0 _ 0 0 0 ,:,;i— . ._ 0 0 L `...., 1 0 0 0 6162 1 0 40 12'.' 40 120 0 6162V 0 0 60 15: a< 0 0 0 6162RF 0 0 120 211 ;o ` 0 0 0 6139/6139R 0 0 40 101 0 0 0 0 0 j 0 0 0 6160/6160CR 1 0 45 150 ] 45 150 0 6160CR-2 1 0 45 160 ]? 1 45 160 0 6160PX _ 0 0 40 165 '".. 1. 0 0 0 6160RF 0 0 50 150t',7] , 0 0 0 6160V 0 0 60 190 ]: 1 0 0 0 6164US ❑using Relay? 0 0 55 210 1 0 0 0 6165EX 0 0 40 70- � It 0 0 0 6460S 0 0 40 150 : iii}. 0 0 0 6460W 0 0 40 150 ',), 1 0 0 0 Tuxedo Family: TUXW/TUXS ❑exlagnt One 0 0 140 340 1 0 0 0 Tux WiFi Family:TUXWIFIW/TUXSWIFI ❑Bacignt On, 0 0 140 350 1 [ 0 0 0 FSA-8 Fire Zone Annunciator 0 0 35 65 ,. 0 0 0 FSA-24 Fire Zone Annunciator 0 0 35 130 1 I 0 0 0 Add?Keypd(Enter#and Currents) 0 0 0 0 'i 1{ 0 _ 0 0 Add?Keypd(Enter#and Currents) 0 0 0 0-, 10 0 0 Add?Keypd(Enter#and Currents) 0 0 00, 7 0 0 0 Add',Keypd(Enter II and Currents) 0 0 0 0"in 0 0 0 • How many Toter 2 WIRE 8 4 WIRE SMOKE DETECTORS(except Vplex Enter powered Standby(aux Alarm Total Polling Standby Total External Polling Loop detectors) Quantify externally? pwr) Conant(And Potting Loop Loop Current Total Alarm Current Current Required 2 wire smoke detector(zone powered) 2 wire smoke detector(zone powered) 0 � 1 rme se err ca ep a rel rim, r,,,,,,, emrs _____. 2 wire smoke detector(zone powered) 0 ngk�" 2 wire smoke detector(zone powered) 12V 4 wire Smoke(Ont y 8 Current 0 0 0 0 _ NA 12V 4 wire Smoke(Ont.),8 Currents) 0 0 0 _ i0 0 0 ti 12V 4 wire Smoke(Only 8 Currents) 0 0 0 �\�AVA� 0 0 0 12V 4 wire Smoke(Ont'r 8 Currents) 0 0 0 0 0 r; Now many Total Enter powered Standby(r 0_i . Tiny Standby Elternal MULTI-POWER DEVICES Quantify .,externally? par) rnr , o:-5:0, Loop Current moral Alarnr Current _ et. 4208U[powered by polling loop] 1 0 0.'3 4208U[powered by panel aux power] 0 ] 4208U[powered externally] 0 _—_____ _ — 4208SN[powered by polling loop] 0 _': 4208SN[powered by panel aux power] 0;. 4208SN[powered externally] 0, 4208SNF[powered by polling loop] 0 4208SNF[powered by panel aux power] 0 ii& 4208SNF[powered externally] 0 IW 4208SNF(Class B to A Zone Converter) 0 __- '_ 4209U Grouped Zone Mux.Module 0 4209U[powered externally] 0 On ( _ 4297 Polling Loop Extender 0 _—_ L_ _� _ ._. _4,__ __ Add?DeviceQenter quant 8 currents) 0 0 _ -- ' ( S Add?Device(enter quant.8 currents) 0 0 010 0 0 S Add?Device(enter quant.8 currents) 0 0 0 c 0 0 0 0 Add'I Device(enter quant.&currents) 0 0 0 --_ 0 0 0 0 How many total Enter powered Standby(aux Alarm ..,,1,,Polling Standby Total External AUXILIARY POWERED DEVICES Quantity externally? pard Cumnt(Aux) Pourng too, .:,nu Current Total Alarm Current Current Regurred PS24 24 volt Power Supply Module 0 0 0 100 j) ;'' 0 0 0 .' 4100SM(no more than one per system) 0 0 25 25 _ 0 0 0 4204:Enter no.of relays used 0 0 40 40� 0 0 0 4204CF:Enter no.of relays used 0 0 80 80 1` ,. ..—I o o 0 4286 with warning speakers 0 0 220 30(: — ---) ___ 0 0 0 5140DLM Backup Dialer Module 1 0 5 1' J 5 15 0 31 of 34 5800RP wireless repeater module 0 0 80 80 _.a, 0 0 0 - 5881EN receiver 0 0 60 60 ,,"'' 0 0 0 5883 hi-security receiver 0 0 80 80 0 0 0 VA8200 Panel Linking Module 0 0 88 88 0 0 0 Add!Device enter quant.&currents) 0 0 0 0 0 0 0 Add'l Device(enter quant.&currents) 0 0 0 0 s0 ? ` 0 0 0 Add'I Device te (enr quant.&currents) 0 0 0 0 .t-. 0 0 0 Add?Device enter.uant.&currents 0 0 0 0 xx 0 o ..„,,,,,,. o r A Communicators _ 7845GSM/7845i-GSM 0 0 10 10 i a\:; 0 0 0z1+ s 7845i/7845i-ENT 0 0 10 10 ': : 0 z :' 0 0 --' GSMX4G 0 0 65 250 S- 0 0 GSMV4G 0 0 10 10 >`,' ;" • � 0 0 0 a iGSMV4G 0 0 10 11) r` 0 0 0 IPGSM-4G 0 0 0 ` 0 0 0 GSMCF/iGSMCF Fire Communicator 0 0 10 10 .. oo�,�;." 0 0 0v �r Vista-GSM4GNista-GSM4GCN Vista-211P onl 0 0 10 10 _ 0 0 0 78471/7847i-E Internet Communicator 0 0 75 75 . ',. 0 0 0 - �. Add?Device enter.uant.&currents 0 0 0 0 a-.. 0 0 0 Add!Device enter.uant.&currents 0 0 0 0 0 0 0 PIR Motion Detectors(non Vplex) IS215T 0 LEDAcove? 0 0 10 7 n•ny '' 0 0 IS215TCE 0 0 18 18 :,fir 0 0 0( IS2260/IS2260T U LED Ache, 0 0 4 4all ""V 0 0 0 IS2460 0 0 9 9_; 0 0 0 IS2500LT 0 0 25 25 i,1%, I 0 0 0 IS2535/IS2535T 0 0 20 20 _._. 0 0 IS2560/IS2560T 0 0 20 20 0 0 0 k IS2560TC 0 0 25 25 -4 0 0 0 ' "" _ i yl IS310/IS320 Request to Exit(RTE) 0 0 35 35'a I 0 0 0 " 997 Ceiling Mount PIR ['LED Awe? 0 0 17 12 n 0 0 0 998 Wall Mount PIR U LED��? 0 0 13 13 0 0 0 Motion Detctrs(enter quant.&currents) 0 0 0 0 '1.1 " o 0 0 Motion Detctrs(enter quant.&currents) 0 0 0 0 AIM -�'i 0 0 0 Motion Detctrs(enter quant.&currents) 0 0 0 0 ' *`i 0 0 0 Motion Detctrs enter.uant.&currents) 0 0 0 0 M. (;. 0 0 0 Dual Tech Motion Detectors(non Vp/ex) DT-515 0 0 20 20 f 0 0 0 DT-6100STC 0 0 35 35._) 0 0 0 DT-7235T 0 0 20 20 .: 0 0 0 DT-7435/DT-7435C 0 0 30 30 0 0 0 DT-7450/DT-7450MIC 0 0 35 35 0 0 0 DT-7550 0 0 40 40 p 0 0 0 DT8035 PIR 5 0 001. 0 0.085 0 Motion Detctrs enter.uant.&currents 0 0 0 0 (. 0 0 0 Motion Detctrs(enter quant.&currents) 0 0 0 0 c A 0 0 0 Motion Detctrs ante-::n -rt;l 0 0 0 0 IMO 0.. r 0� rota; Enter powered by _tan day(a:,x Alarm ,tat Polling S'.andby 7.,ral Lxtenal POLLING LOOP DEVICES Quantity 42977 re:iArr - c Loop ,.,enr rota!Ararrn a.rronr cn -t-ngu,rnd 4101SN Single Output Relay Module 0 0 7 0��:_f. 4190SN Two Zone SIM 0 0 2 0 1 4191SN-WH 0 0). p 0.5 0 4193SN Two Zone SIM 0 0 j;' __ 1.5 0 4193SNP Two Zone SIM 0 0 1.5 0 _ 4209U 0 0 _ 15.5 0 DT7500SN L.)LED AcO`R, 0 0 2.6 0 .: 4293SN 0 0?,. 1 4939SN W H/BR/GY Surf Mt.Cntct. 0 0 1 4944SN Recessed Contact 0 0 , 1 0'� 4945SN-WH 0 0 0.5 0;., 4959SN Overhead Door Contact 0 0 3` ��— 0.5 0 LED Active? —�—. r. 5192SD Smoke Detector ❑ 0 0 1.2 0 �' 5192SDT Smoke w/Heat U LED w? 0 0 1.2 0 `t 5193SD Smoke Detector U LED Amve? 0 0' 1.2 0.?�. 1 5193SDT Smoke w/Heat U LED wow? 0 0€ 1.2 0 '; - _ 998MX PIR U LED Awe 0 a': 1 0 ' ) IS2500SN PIR U LED ad"e? o 0> 1.6 0 \ E FG-1625SN Glass Break Detector 0 0°. 1 0 rte- 1 Quest2260SN U LED Actve? 0 0 c. 6 0 Vplex-VSI Short Isolator 0 0 5 0 Vistakey 0 0= 2 0 Add!VPlex(enter qnt'y&current) 0 0 0 0 Add'I VPlex(enter qnt'y&current) 0 0 g: 0 0 Add'I VPlex(enter qnt'y&current) 0 0 0 c111 AdelV�lex(enter qnt y&cum-nn 0 0 12V NOTIFICATION DEVICES ON HowmanyTotal Tnt Sounder Enter powered _" n,xrn :rel Polling Standby Current!rpm Panel Total Sounder tar ra-. BELL OUTPUT#1 Quantity extamaNy? c Pe, ............... .........1/.,op t.cop Current tW/et current(oxzemaq WAVE2 BELL SIREN 0 0 ' 0 0 Enter device name,quant.,&current 0 0 ' 0 0 Enter device name,quant.,&current 0 0 ; 0 0 Enter device name,quant.,&current 0 0 0 0 Enter device name.quant..&current 0 0 0 0 How many rota; Total Sounder 12V NOTIFICATION DEVICES ON Enter powered Standby iii, A'em Total Polling standby current from Pana Total Sounder BELL OUTPUT#2(IF USED) Quantity externally? pwp -'Ars, hnumg Loop I antero nen w2 current/e,ternan Enter device name,quant.,&current 0 0 tt _ 0 _ Enter device name,quant.,&current 0 0 ii 0 -! Enter device name,quant.,&current 0 0 1 0_ �� Enter device name,quant.,&current 0 0 µ~ 0 0 Enter device name,quant.,&current 0 01 0,, 1,a\LIZ& 4 0 0 32 of 34 Actual Ohms per Alarm Current Resistance Voltage Drop 12V AUX POWER AND BELL CIRCUIT WIRE RUN DATA Una:, Wire Gauge(AWG) 1000 ft Draw(MA) Run Length (twinleads) Whig.At EDL (Peroeng Panel Aux Power Wire Run(twin lead) i,.• . e14 AWG Stranded 3.26 445.09 30 0.20 11.91 0.73 Panel Bell 1 Wire Run(twin lead) =:r1 . rt4AwG Stranded • 3 26 0.00 60 0.39 12.00 0.00 Panel Bell 2 Wire Run(twin lead) ,...ii, xx ,5.4,1 W.,Couae. "" 0.00 0 0 0.00 12.00 0.00 PS24 Power Supply Standby/Alarm Durations(from top) Battery Standby(hours): 24 Alarm Duration(minutes): 5 Required Capacity(AN) 1.059 Use TWO identical batteries w)this AN capacity 7.0 PS24 POWER SUPPLY MODULE,MAXIMUM CAPACITIES I Panel 12V Panel 12V Output A Output A Output B Output B PS24 PC Maximum Total Marimum Total Max.Battery Standby(mA) Alarm(mA) Standby(mA) Alarm(old) Standby(mA) ,,,A) Board(mA) Standby Output Alarm Output Capac:ry ❑using PS24 to back up Cmmtrd Patel 462 942 570 1700 570 1700 40 610 4180 34.4 Total Standby Total Alarm Equivalent panel load @ 24V 0.0 0.0 0 0 0 0 40 40 40 ( H ., ., i" �.�,a Alarm Budget converted to 12VDC from 24V full-wave! StandbyBudget Power Bud et ods 9.10 4 7__ i-�n, -.. )i1 4'4r n 1. Devfos 24V NOTIFICATION APPLIANCES Enter Which PS24 Standby Load Device Alarm Subtotal A Subtotal A Enter Device Names&Specifications ouanuty Output? (MA( Cued(MA) Standby Aram subtotal B Standby Subtotal B Alarm 24V Notification Appliance 01 01 0 0 <_ 0 u 0 0 24V Notification Appliance 01 01 00 %.0 0 0 0 0 24V Notification Appliance OI 0 0 0 0 0 0 0 24V Notification Appliance OI 0 0 0 V; 0 0 0 0 f 24V Notification Appliance 01 0 0 0 _ 0 0 0 0 24V Notification Appliance OI 01 00 P. 0 0 0 0 24V Notification Appliance 01 0 0 0„,, 0 0 0 0 24V Notification Appliance 0,Diet t , 00 1 0 0 Total Alarm Actual Ohms Per (,`arrant Draw Resistance Voltage Drop 24V BELL CIRCUIT WIRE RUN DATA (Jetts wire Gauge(A60) 1000 ft IMA) Run Length (twin reads) Voltage At POOL (Percent) PS24 Output A Wire Run(twin lead) ii,, (Wee Gauge" _• 0.00 0.00 0 0.00 24.00 0.00 e PS24 Output B Wire Run(twin lead) 0.00 0.00 0 0.00 24.00 0.00 33 of 34 Honeywell System Current Draw- HPF602ULADA Total Current Standb 0.075 A Alarm 0.775 A Cl-Non-Alarm Current C2-Alarm Current Device Qty Draw Non-Alarm Qty Draw Alarm 1.System Modules HPF602ULADA Distributed Power Module I 1 I x I 0.07500 I 0.07500 I 1 x I 0.17500 I 0.17500 2.NAC#1 P2R30 1 _ x 0.00000 0.00000 1 , x 0.11600 0.11600 P2R75 2 x 0.00000 0.00000 2 x 0.17600 0.35200 SR15 _ 2 _ x 0.00000 0.00000 2 _ x . 0.06600 - 0.13200 O x 0.00000 0 x 0.00000 O x 0.00000 0 x , 0.00000 _ O x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#1 Totals(Max 3 Amps): 0.00000 0.60000 3.NAC#2 O x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#2 Totals(Max 3 Amps) 0.00000 0.00000 4.NAC#3 0 , x 0.00000 _ 0 x 0.00000 0 , x . 0.00000 0 x 0.00000 0 x 0.00000 _ 0 x 0.00000 0 x 0.00000 0 _ x 0.00000 0 . x 0.00000 0 , x 0.00000 0 . x _ 0.00000 , 0 _ x 0.00000 0 x 0.00000 - 0 x 0.00000 0 x 0.00000 , 0 x 0.00000 NAC#3 Totals(Max 3 Amps) 0.00000 0.00000 5.NAC#4 O x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#4 Totals(Max 3 Amps) 0.00000 0.00000 6.Auxiliary Power Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 _ x 0.00000 _ 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 Auxiliary Device 0 x 0.00000 0 x 0.00000 7.Compatible Devices not listed Other compatible devices 0 , x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Other compatible devices 0 x 0.00000 0 x 0.00000 Total Non-Alarm Load: 0.075 Total Alarm Load: 0.775 34 of 34 • ,p REVIEWED Jacksonville Fire Prevention Div AUG 1 8 2018 co r D C) cn -11 0 " o o z „� ❑ NO EXCEPTIONS m m o _ coo m D D ❑ EXCEPTIONS AS NOTED ci) m m r SHEET# o rn C) -H c7 > z C7 r N O < 2> C r —I N fm D r D 0 , OFFICE Permit Desk APProvetl®y 0 Building n®pertrn®nt Gity of Menne 86seht FL x x ACTUATE BUILDING FIRE ALARM NOTIFICATION APPLIANCES m ACTUATE FACP & FAAP x x ALARM INDICATORS _ ACTUATE FACP & FAAP SUPERVISORY INDICATORS z 0c zz x x x x ACTUATE FACP & FAAP D TROUBLE INDICATORS 0 xxxx x x DEVICE INDICATION AT FACP AND REMOTE ANNUNCIATOR TRANSMIT ALARM SIGNAL TO x CENTRAL MONITORING STATION 0 D � z xxxx TRANSMIT TROUBLE SIGNAL TO N CENTRAL MONITORING STATION z N O TRANSMIT SUPERVISORY SIGNAL TO `1 z CENTRAL MONITORING STATION