886 Ocean Blvd RES19-0279 3rd submittal review comments Permit Reviews City of Atlantic Beach Printed: Thursday, 25 June, 2020 1 of 3 Permit Number: RES19-0279 Description: NEW SINGLE FAMILY HOME Applied: 9/13/2019 Approved: Site Address: 886 OCEAN BLVD Issued: City, State Zip Code: ATLANTIC BEACH, FL 32233 Finaled: Status: AWAITING CORRECTIONS Applicant: <NONE> Parent Permit: Owner: ADAM & JILLIAN EISEMAN Parent Project: Contractor: <NONE> Details: LIST OF REVIEWS SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: 3RD REVIEW 6/11/2020 6/11/2020 SUBMITTAL COMPLETENESS Jennifer Johnston APPROVED W/CONDITIONS Notes: received via FTP with tree permit comments, uploaded as 16 attachments; will need LBTR, GL, & WC prior to permit issuance; recorded NOC required prior to first inspection 6/11/2020 6/19/2020 6/21/2020 ZONING Zoning DENIED Notes: A/C Equipment: The site plan shows the A/C equipment located behind the house but the floor plan shows it located along the north side of the house. Please clarify where the A/C equipment will be located and note that it must be at least 5 feet from property lines. Height of House: Please show that the overall height of the house will not exceed 35 feet from existing (pre-construction) grade of 12.6''. The elevation drawings show grade at 8" below finished floor elevation. However, the spot elevations show existing grade at 12.6'' and FFE at 13.68'', for a difference of 1.08'' in elevation. Please show or note that the height will not exceed 35 feet from the pre-construction grade of 12.6''. 6/11/2020 6/16/2020 6/21/2020 BUILDING Building DENIED Notes: Correction Comments: 1. On page 1 of 5 of the Energy Calculations, the OWNER/AGENT line needs to be filled out and dated. Please correct this page and resubmit. 2. In the Energy Calculation package, the ENERGY PERFORMANCE LEVEL DISPLAY CARD needs to be filled out by the builder and dated. Please correct and resubmit. 6/11/2020 6/12/2020 6/21/2020 PUBLIC WORKS Public Works DENIED Notes: Documentation shows impervious areas are over the 45% allowed by City code. Not enough water retention. Provide a detailed plan of what type of material the driveway is. Review Group: AUTO Permit Reviews City of Atlantic Beach Printed: Thursday, 25 June, 2020 2 of 3 9/13/2019 9/13/2019 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: 9/13/2019 9/24/2019 9/27/2019 BUILDING Building DENIED Notes: Correction Comments: 1. Contractor shall return to the Building Department to complete the permit application by providing the VALUATION OF WORK space which was left blank. Permit application is now incomplete. 2. The Building Department of Atlantic Beach performs plan review on all non-shingled roofs. 2 copies of the manufacturer’s installation instructions and evaluation report are needed for the metal roof system, product approval # 11651.5. 3. This note was added to page A1.1 as a redline note pertaining to the metal stairway system. • R311.7.5.1Risers. The riser height shall be not more than 73/4 inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open risers are permitted provided that the openings located more than 30 inches (762 mm), as measured vertically, to the floor or grade below do not permit the passage of a 4-inch-diameter (102 mm) sphere. 9/13/2019 9/17/2019 9/27/2019 PUBLIC UTILITIES Public Utilities APPROVED W/CONDITIONS Notes: 9/13/2019 9/18/2019 9/27/2019 PUBLIC WORKS Public Works DENIED Received 9/16/19 / Reviewed 9/17/19 Notes: Must file for a Demo Permit before a Residential Permit can be approved. Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1 foot contours. Maximum circular driveway width within the City right-of-way is 12 feet. Circular driveway must have at least a 100 foot frontage. Provide a detailed plan of what type of material the driveway is. Provide a detailed plan of driveway in City right-of-way. Provide detailed plans showing proposed water retention. Submitted water retention is figured off old calculations. Water retention cannot be within 10 feet of house. Documentation shows impervious areas are over the 45% allowed by City code. 9/13/2019 9/25/2019 9/27/2019 ZONING Zoning DENIED Notes: Tree Permit: Please pay for the submitted tree removal permit. Topo Survey: Please submit pre-construction topographical survey of lot. Driveway Width: The Maximum driveway width is 20 feet. Circular Driveway: The minimum lot width for circular driveways is 100 feet. Mechanical Equipment: A/C and other mechanical equipment is not allowed within 5 feet of the property line. Please revise accordingly. Height from Grade: Please show the overall height of the house from pre-construction grade, not finished floor. Side Yard Projections: Roof overhangs and architectural features (i.e. bump-outs) are allowed to project a combined 2 feet into side yard setbacks. The proposed 2 foot bump-outs with 1 foot overhang exceed this allowance by 1 foot. Please revise so that no part of either the bump-out or overhang are more than 2 feet into the side setbacks. Side Wall Features: Please reduce the length of the side wall bump-outs. We allow bump-outs that are similar to bay windows but not complete rooms Permit Reviews City of Atlantic Beach Printed: Thursday, 25 June, 2020 3 of 3 or large areas. Please reduce the lengths of these bump-outs to replicate bay windows or revise similarly. Review Group: 1ST REVIEW 10/2/2019 10/2/2019 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: DETAIL SHOWING ELEVATIONS EMAILED 9/30/19 10/2/2019 10/2/2019 10/16/2019 ZONING Zoning DENIED Notes: Same as first round