Loading...
610 Begonia St RES19-0016 Permit Inspection ReportLIST OF INSPECTIONS SEQ ID SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS CO BUILDING Mike Jones Notes: 5/2/2019 5/2/2019 BUILDING FOUNDATION FOOTING Mike Jones CANCELLED Notes: 237-0523 Structural drawings not stamp by building department. Cancelled inspection per Dan A. 5/10/2019 5/10/2019 BUILDING FOOTER Dan Arlington FAILED WITH FEE Notes: JOE 237-0523 per dan 5/13/2019 5/13/2019 BUILDING FOOTER Dan Arlington PASSED Notes: Joe 904-230-0523 5/31/2019 5/31/2019 BUILDING MASONRY WALLS Rick Bell PASSED Notes: Joe: 237-0523 6/3/2019 6/3/2019 BUILDING MASONRY WALLS Rick Bell CANCELLED Notes: *Cancel if passed on 5/31/19* Joe: 237-0523 6/14/2019 6/14/2019 BUILDING SLAB Mike Jones FAILED WITH FEE Notes: Joe: 237-0523 Permit Number: RES19-0016 Site Address: 610 BEGONIA City, State Zip Code: ATLANTIC BEACH, FL 32233 Applied: 1/15/2019 Approved: 2/12/2019 Issued: 2/20/2019 Parent Permit: Parent Project: Applicant: <NONE> Owner: HOLSTAR LLC Contractor: <NONE> Description: new single-family home Finaled: Status: ISSUED Details: Printed: Thursday, 18 June, 2020 1 of 6 Permit Inspections City of Atlantic Beach 1. A form board survey is needed for the slab inspection. 2. The placement of rebar at the step down area at the garage was not installed according to C2/S3.2. 3. Footers were not cut into soil correctly according to detail C2/S3.2. 4. Rebar placement at south garage floor to wall was not placed correctly. 5. Soil needs to be cleaned off of perimeter top course of blockwork. 6. #4 horizontal steel at perimeter needs to be removed and place on top of bent over vertical wall steel. where it is place now concrete is unable to get around and cover it. 6/18/2019 Any 6/18/2019 BUILDING SLAB Mike Jones CANCELLED eTRAKiT Inspection Request Notes: 6/17/2019 3:25 PM North Florida Construction Company, LLC Joe 904-237-0523 Contact Name: North Florida Construction Company, LLC Site Address: 610 BEGONIA Phone: 9042370523 e-Mail: northfloridallc@gmail.com not ready 6/19/2019 Any 6/19/2019 BUILDING SLAB Mike Jones PASSED eTRAKiT Inspection Request Notes: 6/18/2019 3:27 PM North Florida Construction Company, LLC 904-237-0523 Contact Name: North Florida Construction Company, LLC Site Address: 610 BEGONIA Phone: 9042370523 e-Mail: northfloridallc@gmail.com 6/28/2019 6/28/2019 BUILDING WALL SHEATHING Dan Arlington FAILED NO FEE Notes: Verify engineering detail S3.2/C-3 at garage door. OK to house wrap and windows. 6/28/2019 6/28/2019 ROOF SHEATHING Dan Arlington CANCELLED Notes: Joe: 237-0523 PM 7/9/2019 7/10/2019 ROOF SHEATHING Rick Bell CANCELLED Notes: Joe: 237-0523 7/12/2019 7/12/2019 ROOF SHEATHING Rick Bell PASSED Notes: AM 7/23/2019 7/23/2019 BUILDING WALL SHEATHING Dan Arlington FAILED WITH FEE Notes: Joe: 237-0523 Not per plan first inspection. Not per revised detail second inspection. 7/29/2019 7/29/2019 BUILDING WALL SHEATHING Rick Bell PASSED Notes: Joe: 237-0523 Printed: Thursday, 18 June, 2020 2 of 6 Permit Inspections City of Atlantic Beach 7/29/2019 7/29/2019 ROOF IN PROGRESS Rick Bell PASSED Notes: 8/19/2019 8/19/2019 BUILDING HOUSE WRAP Dan Arlington FAILED WITH FEE Notes: 237-0523 TI VACK WINDOW & DOORS Improper laps over windows. Does not comply with window detail in plans. 8/22/2019 8/22/2019 BUILDING TIE DOWN FRAMING Dan Arlington PASSED Notes: 237-0523 8/22/2019 8/22/2019 BUILDING WINDOW DOOR INSTALL Dan Arlington PARTIALLY PASSED Notes: Back ordered - rear SGDr. OK to install siding. 8/22/2019 8/22/2019 BUILDING HOUSE WRAP Dan Arlington PASSED Notes: 237-0523 8/26/2019 8/26/2019 BUILDING WINDOW DOOR FINAL** Dan Arlington PASSED Notes: 8/26/2019 8/26/2019 BUILDING WINDOW DOOR INSTALL Dan Arlington PASSED Notes: 8/26/2019 8/26/2019 BUILDING SIDING IN PROGRESS Dan Arlington PASSED Notes: Joe: 237-0523 8/28/2019 8/28/2019 BUILDING FRAMING ROUGH Rick Bell PASSED Notes: Joe: 237-0523 Printed: Thursday, 18 June, 2020 3 of 6 Permit Inspections City of Atlantic Beach 9/3/2019 9/5/2019 BUILDING INSULATION CEILING Rick Bell PASSED Notes: Joe: 237-0523 9/3/2019 9/5/2019 BUILDING INSULATION WALLS Rick Bell PASSED Notes: Joe: 237-0523 2/10/2020 2/10/2020 BUILDING FINAL**Rick Bell FAILED WITH FEE Notes: Joe 904-237-0523 lock box code - 4976 front steps >7.75" gar steps > 3/8" diff stove anti tip missing back deck bottom step >7.75" strikes in fr dr need 2.5" screws 2/28/2020 2/28/2020 BUILDING FINAL**Dan Arlington FAILED WITH FEE Notes: Joe 904-237-0523 lock box code - 4976 Two items on previous correction list not done. Hand rail and screws in strike plates. 3/4/2020 3/4/2020 BUILDING FINAL**Rick Bell FAILED WITH FEE Notes: Joe 904-237-0523 lock box code - 4976 Needs greppable handrail with returned ends in gar & back deck 3/6/2020 3/6/2020 BUILDING FINAL**Dan Arlington PASSED Notes: Stephen: 891-6080 lock box code - 4976 3/10/2020 3/10/2020 CO PUBLIC UTILITIES BACKFLOW Malcolm Clemons PASSED Notes: Stephen: 891-6080 lock box code - 4976 Backflow RPZ present Printed: Thursday, 18 June, 2020 4 of 6 Permit Inspections City of Atlantic Beach 3/10/2020 3/11/2020 CO ZONING Brian Broedell PASSED Notes: 3/10/2020 3/12/2020 CO PUBLIC WORKS Scott Williams FAILED NO FEE Notes: Side swells have not been put in according to the civil plan submitted at permitting time. Need to put in the side swells and have a topo to show them. 3/10/2020 3/13/2020 CO PUBLIC UTILITIES Emanuel Brown FAILED NO FEE Notes: Did not see tie in for this property 6/4/2020 6/4/2020 CO PUBLIC UTILITIES Emanuel Brown PASSED Notes: Joe: 237-0523 6/4/2020 6/4/2020 CO PUBLIC WORKS Scott Williams FAILED WITH FEE Notes: Joe: 237-0523 1. Need a TOPO showing elevations of swales on both sides of house. 2. Swale on the South side is not even on this property. 3. Does not appear that the swales are deep enough. 6/8/2020 6/5/2020 CO BUILDING Mike Jones PASSED Notes: Joe: 237-0523 Pending all departments approve their CO inspections 6/8/2020 6/8/2020 CO PUBLIC WORKS Scott Williams FAILED NO FEE Notes: Joe: 237-0523 Steve – I reviewed the drawing. You are asking for a modification of the grading plan approved by the City as shown on the attached drawings signed 08 -21-19. The drawing you submitted is only for Lot 5. Since the grading on Lot 6 is going to change, you need to submit a modified plan for that too. I think we talked about that last week. – Steve 6/11/2020 6/11/2020 CO ZONING Brian Broedell PASSED Notes: NEW SUREVEY 6-11-20 6/11/2020 CO BUILDING Dan Arlington Notes: NEW SURVEY 6-11-20 6/11/2020 6/12/2020 CO PUBLIC WORKS Scott Williams PASSED Notes: NEW SURVEY 6-11-20 6/15/2020 6/12/2020 CO PUBLIC WORKS Scott Williams PASSED Notes: Did this one Last Friday. Approved Printed: Thursday, 18 June, 2020 5 of 6 Permit Inspections City of Atlantic Beach 6/17/2020 CO PUBLIC WORKS Scott Williams Notes: final survey 6-16-20 6/17/2020 6/17/2020 CO ZONING Brian Broedell PASSED Notes: final survey 6-16-20 6/17/2020 6/18/2020 CO BUILDING Mike Jones FAILED NO FEE Notes: final survey 6-16-20 Fences installed with out permits. Printed: Thursday, 18 June, 2020 6 of 6 Permit Inspections City of Atlantic Beach