610 Begonia St RES19-0016 Permit Inspection ReportLIST OF INSPECTIONS
SEQ
ID SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS
CO BUILDING Mike Jones
Notes:
5/2/2019 5/2/2019
BUILDING
FOUNDATION
FOOTING
Mike Jones CANCELLED
Notes:
237-0523
Structural drawings not stamp by building department. Cancelled inspection per Dan A.
5/10/2019 5/10/2019 BUILDING FOOTER Dan Arlington FAILED WITH
FEE
Notes:
JOE 237-0523
per dan
5/13/2019 5/13/2019 BUILDING FOOTER Dan Arlington PASSED
Notes:
Joe
904-230-0523
5/31/2019 5/31/2019 BUILDING
MASONRY WALLS Rick Bell PASSED
Notes:
Joe: 237-0523
6/3/2019 6/3/2019 BUILDING
MASONRY WALLS Rick Bell CANCELLED
Notes:
*Cancel if passed on 5/31/19*
Joe: 237-0523
6/14/2019 6/14/2019 BUILDING SLAB Mike Jones FAILED WITH
FEE
Notes:
Joe: 237-0523
Permit Number: RES19-0016
Site Address: 610 BEGONIA
City, State Zip Code: ATLANTIC BEACH, FL 32233
Applied: 1/15/2019 Approved: 2/12/2019
Issued: 2/20/2019
Parent Permit:
Parent Project:
Applicant: <NONE>
Owner: HOLSTAR LLC
Contractor: <NONE>
Description: new single-family home
Finaled:
Status: ISSUED
Details:
Printed: Thursday, 18 June, 2020 1 of 6
Permit Inspections
City of Atlantic Beach
1. A form board survey is needed for the slab inspection. 2. The placement of rebar at the step down area at the garage was not installed according to
C2/S3.2. 3. Footers were not cut into soil correctly according to detail C2/S3.2. 4. Rebar placement at south garage floor to wall was not placed
correctly. 5. Soil needs to be cleaned off of perimeter top course of blockwork. 6. #4 horizontal steel at perimeter needs to be removed and place on
top of bent over vertical wall steel. where it is place now concrete is unable to get around and cover it.
6/18/2019 Any 6/18/2019 BUILDING SLAB Mike Jones CANCELLED eTRAKiT Inspection Request
Notes:
6/17/2019 3:25 PM North Florida Construction Company, LLC
Joe
904-237-0523
Contact Name: North Florida Construction Company, LLC
Site Address: 610 BEGONIA
Phone: 9042370523
e-Mail: northfloridallc@gmail.com
not ready
6/19/2019 Any 6/19/2019 BUILDING SLAB Mike Jones PASSED eTRAKiT Inspection Request
Notes:
6/18/2019 3:27 PM North Florida Construction Company, LLC
904-237-0523
Contact Name: North Florida Construction Company, LLC
Site Address: 610 BEGONIA
Phone: 9042370523
e-Mail: northfloridallc@gmail.com
6/28/2019 6/28/2019 BUILDING WALL
SHEATHING Dan Arlington FAILED NO FEE
Notes:
Verify engineering detail S3.2/C-3 at garage door.
OK to house wrap and windows.
6/28/2019 6/28/2019 ROOF SHEATHING Dan Arlington CANCELLED
Notes:
Joe: 237-0523
PM
7/9/2019 7/10/2019 ROOF SHEATHING Rick Bell CANCELLED
Notes:
Joe: 237-0523
7/12/2019 7/12/2019 ROOF SHEATHING Rick Bell PASSED
Notes:
AM
7/23/2019 7/23/2019 BUILDING WALL
SHEATHING Dan Arlington FAILED WITH
FEE
Notes:
Joe: 237-0523
Not per plan first inspection.
Not per revised detail second inspection.
7/29/2019 7/29/2019 BUILDING WALL
SHEATHING Rick Bell PASSED
Notes:
Joe: 237-0523
Printed: Thursday, 18 June, 2020 2 of 6
Permit Inspections
City of Atlantic Beach
7/29/2019 7/29/2019 ROOF IN
PROGRESS Rick Bell PASSED
Notes:
8/19/2019 8/19/2019 BUILDING HOUSE
WRAP Dan Arlington FAILED WITH
FEE
Notes:
237-0523
TI VACK
WINDOW & DOORS
Improper laps over windows.
Does not comply with window detail in plans.
8/22/2019 8/22/2019 BUILDING TIE
DOWN FRAMING Dan Arlington PASSED
Notes:
237-0523
8/22/2019 8/22/2019
BUILDING
WINDOW DOOR
INSTALL
Dan Arlington PARTIALLY
PASSED
Notes:
Back ordered - rear SGDr.
OK to install siding.
8/22/2019 8/22/2019 BUILDING HOUSE
WRAP Dan Arlington PASSED
Notes:
237-0523
8/26/2019 8/26/2019
BUILDING
WINDOW DOOR
FINAL**
Dan Arlington PASSED
Notes:
8/26/2019 8/26/2019
BUILDING
WINDOW DOOR
INSTALL
Dan Arlington PASSED
Notes:
8/26/2019 8/26/2019 BUILDING SIDING
IN PROGRESS Dan Arlington PASSED
Notes:
Joe: 237-0523
8/28/2019 8/28/2019 BUILDING
FRAMING ROUGH Rick Bell PASSED
Notes:
Joe: 237-0523
Printed: Thursday, 18 June, 2020 3 of 6
Permit Inspections
City of Atlantic Beach
9/3/2019 9/5/2019
BUILDING
INSULATION
CEILING
Rick Bell PASSED
Notes:
Joe: 237-0523
9/3/2019 9/5/2019
BUILDING
INSULATION
WALLS
Rick Bell PASSED
Notes:
Joe: 237-0523
2/10/2020 2/10/2020 BUILDING FINAL**Rick Bell FAILED WITH
FEE
Notes:
Joe
904-237-0523
lock box code - 4976
front steps >7.75"
gar steps > 3/8" diff
stove anti tip missing
back deck bottom step >7.75"
strikes in fr dr need 2.5" screws
2/28/2020 2/28/2020 BUILDING FINAL**Dan Arlington FAILED WITH
FEE
Notes:
Joe
904-237-0523
lock box code - 4976
Two items on previous correction list not done.
Hand rail and screws in strike plates.
3/4/2020 3/4/2020 BUILDING FINAL**Rick Bell FAILED WITH
FEE
Notes:
Joe
904-237-0523
lock box code - 4976
Needs greppable handrail with returned ends in gar & back deck
3/6/2020 3/6/2020 BUILDING FINAL**Dan Arlington PASSED
Notes:
Stephen: 891-6080
lock box code - 4976
3/10/2020 3/10/2020
CO PUBLIC
UTILITIES
BACKFLOW
Malcolm
Clemons PASSED
Notes:
Stephen: 891-6080
lock box code - 4976
Backflow RPZ present
Printed: Thursday, 18 June, 2020 4 of 6
Permit Inspections
City of Atlantic Beach
3/10/2020 3/11/2020 CO ZONING Brian Broedell PASSED
Notes:
3/10/2020 3/12/2020 CO PUBLIC WORKS Scott Williams FAILED NO FEE
Notes:
Side swells have not been put in according to the civil plan submitted at permitting time. Need to put in the side swells and have a topo to show them.
3/10/2020 3/13/2020 CO PUBLIC
UTILITIES Emanuel Brown FAILED NO FEE
Notes:
Did not see tie in for this property
6/4/2020 6/4/2020 CO PUBLIC
UTILITIES Emanuel Brown PASSED
Notes:
Joe: 237-0523
6/4/2020 6/4/2020 CO PUBLIC WORKS Scott Williams FAILED WITH
FEE
Notes:
Joe: 237-0523
1. Need a TOPO showing elevations of swales on both sides of house.
2. Swale on the South side is not even on this property.
3. Does not appear that the swales are deep enough.
6/8/2020 6/5/2020 CO BUILDING Mike Jones PASSED
Notes:
Joe: 237-0523
Pending all departments approve their CO inspections
6/8/2020 6/8/2020 CO PUBLIC WORKS Scott Williams FAILED NO FEE
Notes:
Joe: 237-0523
Steve – I reviewed the drawing. You are asking for a modification of the grading plan approved by the City as shown on the attached drawings signed 08
-21-19. The drawing you submitted is only for Lot 5. Since the grading on Lot 6 is going to change, you need to submit a modified plan for that too. I
think we talked about that last week. – Steve
6/11/2020 6/11/2020 CO ZONING Brian Broedell PASSED
Notes:
NEW SUREVEY 6-11-20
6/11/2020 CO BUILDING Dan Arlington
Notes:
NEW SURVEY 6-11-20
6/11/2020 6/12/2020 CO PUBLIC WORKS Scott Williams PASSED
Notes:
NEW SURVEY 6-11-20
6/15/2020 6/12/2020 CO PUBLIC WORKS Scott Williams PASSED
Notes:
Did this one Last Friday. Approved
Printed: Thursday, 18 June, 2020 5 of 6
Permit Inspections
City of Atlantic Beach
6/17/2020 CO PUBLIC WORKS Scott Williams
Notes:
final survey 6-16-20
6/17/2020 6/17/2020 CO ZONING Brian Broedell PASSED
Notes:
final survey 6-16-20
6/17/2020 6/18/2020 CO BUILDING Mike Jones FAILED NO FEE
Notes:
final survey 6-16-20
Fences installed with out permits.
Printed: Thursday, 18 June, 2020 6 of 6
Permit Inspections
City of Atlantic Beach