569 Timber Bridge Ln ACC20-0053 Outdoor Kitchen PermitOWNER:ADDRESS:CITY:STATE:ZIP:
WHITEHEAD TERRY E 569 Timber Bridge Lane Atlantic Beach Fl 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
Pratt Guys, Inc.6967 Phillips HWY JACKSONVILLE FL 32216
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169505 2055 ATLANTIC BEACH
COUNTRY CLUB UNIT 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
569 TIMBER BRIDGE LN
RESIDENTIAL OTHER SINGLE OR
TWO FAMILY RESIDENTIAL
OTHER
OUTDOOR KITCHEN $7500.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 8/27/2020
PERMIT NUMBER
ACC20-0053
ISSUED: 8/27/2020
EXPIRES: 2/23/2021
RESIDENTIAL OTHER PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $90.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00
PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00
TOTAL: $264.03
2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
4 PUBLIC WORKS RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site. Cannot raise lot elevation.
5 PUBLIC WORKS DECKING REMOVED INFORMATIONAL
Notes:
All old decking and debris must be removed from job site by Contractor.
2 of 2Issued Date: 8/27/2020
PERMIT NUMBER
ACC20-0053
ISSUED: 8/27/2020
EXPIRES: 2/23/2021
RESIDENTIAL OTHER PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $264.03
ACC20-0053 Address: 569 TIMBER BRIDGE LN APN: 169505 2055 $264.03
BUILDING $90.00
BUILDING PERMIT 455-0000-322-1000 0 $90.00
BUILDING PLAN REVIEW $45.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00
PUBLIC WORKS PLAN REVIEW $25.00
PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00
STATE SURCHARGES $4.03
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
ZONING PLAN REVIEW $100.00
ZONING REVIEW SINGLE AND TWO FAMILY
USES 001-0000-329-1003 0 $100.00
TOTAL FEES PAID BY RECEIPT: R12993 $264.03
Printed: Thursday, August 27, 2020 8:16 AM
Date Paid: Wednesday, August 26, 2020
Paid By: Justin Belichis
Pay Method: CREDIT CARD 356553597
1 of 1
Cashier: JJ
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R12993
1
IMPORTANT
PERMIT AND INSPECTION NOTES
BUILDING.
1. The City Sea Turtle Protection Ordinance applies where land either has frontage on Beach Avenue, the
Cloister Condominium, or is located eastward of Seminole Road from 20th Street northward to the City Limits.
2. No fill dirt can be delivered without prior approval from Public Works. Per COAB, 24-68.
3. The bottom of all foundation footings must be minimum 12 inches below existing grade, per COAB, 24-68
and FBC-B, Section 403.1.4. Site conditions may require footings to be deeper or higher above finished grade.
Please review COAB Bulletin 1-16 to ensure minimum Finished Floor Elevation (FFE).
4. Fill dirt inside foundation walls must be compacted in 8-inch lifts, per FBC-R506.2.1. Please submit
compaction tests, from a third-party testing agency, for every 16 inches of fill or fraction thereof.
5. At Final Inspection, a 6-inch clearance between exterior wall coverings and final grade (top of sod or mulch)
will be required, per FBC-R318.7. Please plan FFE and lot grading accordingly.
6. Where questionable soils are found, during inspection, soil and compaction tests may be required, per FBC-
R401.
7. Please provide a form-board or stem wall elevation form, from a licensed surveyor, for slab inspection.
8. Please review COAB Bulletin 2-18 to determine if a survey with setbacks and dimensions to property lines is
required for slab inspection.
9. The placement and protection of steel reinforcement (Rebar) must comply with FBC-R606 (Masonry) and
R608 (Concrete), including required Standard Hooks at top and bottom of vertical rebar.
10. Inspections:
a. In-Progress Inspections are required for Exterior Siding and Window and Door Inspections and
should be scheduled for the first day of work.
b. A Scratch-Coat Inspection is required for stucco work. If you intend to apply a double-up, brown-
coat, please call the Building Department to schedule a same-day Scratch-Coat Inspection.
c. All roofing projects require an In-Progress Inspection, Residential and Commercial.
d. The roof must be complete and the building dried in before scheduling rough trades inspections.
11. The joint tape for ZIP Board products is considered the dry-in or House Wrap for the building and must be
inspected before covering over. All holes and penetrations in the sheathing and overdriven nails must be
sealed.
12. Please post the building permit documents in a conspicuous location, before start of construction,
including the Building Permit, Notice Of Commencement (NOC), and Construction Site Management Plan. The
Police Department may review the management plan for compliance and parking.
13. Blocking any sidewalk or street is prohibited without prior approval from the Police Department and City
Manager.
2
14. All work must match the approved plans. All changes to the approved plans must be re-submitted for plan
review and approved before it can be inspected. Building inspectors are not authorized to approve changes to
the approved plans in the field. (See Mechanical)
15. Where excavation is required for new construction, the provisions of FBC-B, Section 3307 will apply,
including a 10-Day prior notice to adjoining property owners and protection of adjoining properties. Where
the excavation exceeds 24 inches, temporary retaining walls must designed by the Engineer Of Record (EOR)
and installed during or immediately after excavation.
EXISTING BUILDINGS – REMODELS, RENOVATIONS, ADDITIONS, CHANGE OF OCCUPANCY.
1. Existing buildings are reviewed and permitted under the Florida Building Code-Existing Buildings (FBC-
EB). The applicant must specify the method of compliance, per FBC-EB 301.1, and include that
information on the plans, with the Design Criteria and Code Analysis.
2. The requirements for the method specified will be found in the corresponding FBC-EB Chapter.
3. When it is discovered during construction that the Compliance Method is not correct, or the project
has expanded into another Compliance Method, revised plans will be required to update the Permit.
No inspections will be conducted until the approved revisions are on site.
4. Any wall opened by removing interior or exterior wall coverings is considered a Work Area, and current
provisions for Energy Conservation, including weatherproofing and insulation will apply.
5. Building inspectors are not authorized to approve changes to the approved plans in the field.
ROOFING.
a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing
Inspection is approved.
b. All roofing projects require an In-Progress Inspection.
c. Sheathing installation and replacement guidelines per APA.
d. Underlayment must conform to FBC-R Table 905.1.1
e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F
ELECTRICAL.
1. Electrical work must comply with the provisions of the 2014 NEC.
2. Anti-Oxidant Compound is required on all exterior aluminum wiring connections, unless the Listing
Approval Documents for the conductors and the termination points, at each end, specifically allow
connection without the compound. (Three documents will be required)
PLUMBING.
1. Water supply and drain pipes must be insulated outside of conditioned areas, per FBC-R, P2603.5.
2. Where the entire sanitary drainage system is replaced, the existing building drain and building sewer
3
must be internally examined to verify proper size and slope and that piping is not broken or obstructed,
per FBC-R, P2502.1.
3. COAB requires an additional sewer cleanout near the sewer tap with a T-1 concrete box for protection.
4. Water service piping must be properly supported and covered by a minimum of 12 inches of soil, per
FBC-R, P2604.3.
MECHANICAL.
1. All equipment and duct work must match the approved plans and Energy Sheets.
The Manual S is the approved duct plan, and the as-built duct work must match the approved plans, or
a revised Manual S or equivalent must be submitted for review. An equivalent must include duct and
trunk layout and sizes, available static pressure, actual air flow, and total effective length, signed by the
Mechanical Contractor with State License Number.
FUEL GAS.
1. Fuel gas systems from the regulator to the appliances must comply with the FBC-Gas.
2. LP gas storage systems and outside piping must comply with NFPA 58.
3. All underground gas piping and tubing must be buried with 12-inches of cover.
4. CSST gas piping must comply with the manufacturer’s installation instructions and terms of approval.
4
01/23/20, 02/13/20
ACC20-0053
ACC20-0053
6'-7"
96
'
-
4
"
43'-9"
39
'
-
4
"
PROPOSED
OUTDOOR
KITCHEN
*** SETBACKS MEASURED TO WALLS ***
*** PROPOSED STRUCTURE NOT TO
IMPACT LOT COVERAGE BY BUILDINGS
OR IMPERVIOUS SURFACES***
ACC20-0053
DESIGN GUIDE PROJECT NO.
20026
A3
Dori & Terry Whitehead
569 Timberbridge Lane
Atlantic Beach, Fl 32233
PATIO MATERIAL OVERVIEW
KITCHEN APPLIANCES03SCALE: 1" = 1'-0"
�WALL BLOCK
Material: Stonegate
Color: Sierra
Quantity: ~12 LN FT
�COUNTERTOP
Material: Granite
Color: Uba Tuba
Quantity: ~26 SQ FT
WALL BLOCK OVERHEAD01SCALE: 1" = 1'-0"
COUNTERTOP CUTOUTS04SCALE: 1" = 1'-0"
WALL BLOCK ELEVATIONS02SCALE: 1" = 1'-0"
NOTE: ALL COUNTERTOPS TO BE TEMPLETATED
IN FIELD PRIOR TO BEING CUT
KITCHEN MATERIALS
�DELTA HEAT
- 32" Grill (2020)
- 32" Vinyl Cover
- 30" Door & Two Drawer Combo
- 18" Single Access Door
�POLARIS
- 21"x16" Undermount Sink & Faucet
�TRUE
- Outdoor Refrigerator (Solid Door)
KITCHEN APPLIANCES
EXISTING COLUMN
RESIDENCE WALL
EDGE OF EXISTING LANAI
2'-6"
NOTCH WALL BLOCK
FOR SINK
3'-0"
9 1/4"1'-4 1/4"9 7/8"2'-5 1/4"
9'-1 3/8"
9'-1 3/8"
6 5/8"
10 5/8"2'-1/8"10"
1'-7"
6 5/8"
1'-7"
8 1/4"
POLARIS 21x16 UNDERMOUNT
SINK & FAUCET
DELTA HEAT
18" SINGLE ACCESS DOOR
DELTA HEAT
32" GRILL
DELTA HEAT
30" DOOR & TWO DRAWER COMBO TRUE
24" REFRIGERATOR (SOLID DOOR)
1'-7 1/2"
7 5/8"
4"
3"
2'-10 3/4"2'-6 1/2"
9'-2 3/8"
2'-8 3/4"
11"
7 7/8"
7 3/4"
1'-7"
NOTCH AROUND
EXISTING COLUMN
ACC20-0053
ACC20-0053