Loading...
1085 Atlantic Blvd 82 COMM20-0020 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: NCM LLC ET AL P.O.BOX 309 BRIDGEPORT CT 06601 COMPANY:ADDRESS:CITY:STATE:ZIP: Southeastern Construction and Rehab Specialists 8219 Ulmerton Rd Unit A4 Largo FL 33771 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 177391 0000 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1085 ATLANTIC BLVD COMMERCIAL ALTERATION COMMERCIAL Unit 82 - apartment remodel from 4/1 to 3/2 $35000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $230.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $115.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.18 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.45 TOTAL: $353.63 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 8/31/2020 PERMIT NUMBER COMM20-0020 ISSUED: 8/31/2020 EXPIRES: 2/27/2021 COMMERCIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 8/31/2020 PERMIT NUMBER COMM20-0020 ISSUED: 8/31/2020 EXPIRES: 2/27/2021 COMMERCIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $353.63 COMM20-0020 Address: 1085 ATLANTIC BLVD APN: 177391 0000 $353.63 BUILDING $230.00 BUILDING PERMIT 455-0000-322-1000 0 $230.00 BUILDING PLAN REVIEW $115.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $115.00 STATE SURCHARGES $8.63 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.18 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.45 TOTAL FEES PAID BY RECEIPT: R13044 $353.63 Printed: Monday, August 31, 2020 10:09 AM Date Paid: Monday, August 31, 2020 Paid By: Southeastern Construction and Rehab Specialists Pay Method: CREDIT CARD 357678452 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R13044 1111!! ·~ TRAKiT ~:,, Building Permit Application ((. -ti} City of Atlantic Beach Building Department ' ,; ___ /) 800 Seminole Road, Atlantic Beach, FL 32233 ··.?~J]~i':,!!-= -Phone: (904) 247-5826 Email: Building-Dept(a>coab.us Updar,•d 10/9/18 **ALL INFORMATION HIGHLll3 HTED IN GRAY IS ~EQUIRED. Job Address: 1085 Atlantic Blvd. Atlantic Beach, FL 32233 -Unit:82 Permit Number: __________ _ Legal Description 38-2S-29E 6.374 BOE CASTRO Y FE RRER GRANT PT RECD O/R 18730-1316 177391-0001) RE# _________ _ Valuation of Work (Replacement Cost) $ 35,000.00 Heated/Cooled SF ·--~ Non-Heated/Cooled C • Class of Work : □New □Addition IXlAlteration □Repair □Move □Demo □Pool □Window/Door • Use of existing/proposed structure(s): □Commercia l !29Residential/ Multi Family Ai;:artme11t If an existing stru cture. is a fire sprinkler system installed?: □Yes ®No • Will t reelsl be removed in association with nronosed nroiect? □Yes /must submit senarate Tree Removal Pe rmit\ ~No Describe in detail the type of work to be performed: Remodel Apartment Unit from a 4bedroom/1bath to a 3bedroom/2 bath. Including new kitchen cabinets and appliances. new bathroom fix tur es. new bathroom window. Floor Finishes. & Pair.I Florida Product Approval/# _____________ _ _ __ for multiple products use product a~lproval form Property Owner Information Name NMC. LLC Address _ _..;__P_O_Bo_x_J_0_9 __________ , ___ _ City Bridgeport State _c_T __ Zip 06601 Phone ________ --'---- E-Ma il _________________________________________ _ Owner o r Agent (If Agent, Power of Attorney or Agency Letter Required) ___________________ _ Contractor Information \.-.... ___ :,.li~ l-LL , LL' · Name of Company ~~tQW~~o.o{ ~ ::,(JC',ll"Qualifying Agent Qvt ~bu:: fu1 ~1~,t/ Address 3J.\q U\C'f\etton M~i\:f!.Y City Lo...r(jt> State Ek ZiP3 ~-71 I Office Phone <o,B c,q l lc:H4 Job Site Contact Number j>?d--;n,i-sc~~ State Certification/Registration It CGC\ S'J}0J \ E-Mail Heac:\WY@~O"O>O~m>C;tjOO ;u)l't) Architect Name & Phone II Jimmy L Powers 210 4081860 Engineer's Name & Phone II _N_t_A-=------------------------------------ Workers Compensation Insu r er A:mtr:;c.n,:, S\i,rl.tt':) OR Exempt U Expira tion Date OJ_\ 01 j ..2 O,I. \ Application is h ereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed lo meet the sta ndards of all the laws re1:ulating con5lruction in this Jurisdiction. I u nderstand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, !>IGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requireme!n ts of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agE!ncies, or federal agencies . OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that a ll work will be done in compl iance w ith all applicable laws regulating con struction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE ;:i<f'Personally Kriown OR [ I Produced Identification Typa of ldent ific:atinn : __ _ KIMBERLY A. MICHAUD Notary-Pobltc, Connectrclit My Commission Expires Nov. 30, 2024 NOTICE TO CONTRACTORS: ALL CONTRACTORS PRIOR TO BID SUBMISSION PROCESS SHALL VISIT PROPOSED IAIORK SITE AND FIELD VERIFY ALL EXISTIN& CONDITIONS. ANY CONDITION THAT DIFFERS FROM THAT SHOWN ON THESE PLANS SHALL BE REPORTED TO THE TENANT'S ARCHITECT/EN&INEER SO THAT NEY'! AND REVISED BID DRAY'IIN&S OR INFORMATION MAY BE ISSUED. MODIFICATIONS TO THE SCOPE OF WORK WHICH RESULTS FROM THE CONTRACTORS NE&LECT TO VISIT THE SITE PRIOR TO SUBMITTING BID, SHALL BE THE CONTRACTORS SOLE RESPONSIBILITY. LEGEND EXISTIN5 Y¼LLS AND ITEMS TO 61:: l':EMOYED EXl5TIN5 Y'lAl.1..5 AND ITEMS TO F:EMAIN ~ EXISTINIS DOOR ~ N!:l'lDOOR ,o KITCHEN ,--·-··-------- 1 ® I _________ _ q JI 71 II / / II / LIVING / DINING / U/ Cc==~l l " ;,, ✓ " :? -/ ' C / / BEDROOM HALL "'· II , --------~"" • J BEDROOM q)---~ I / II / II // II/ CD ~~~s.s.~~~ON PLAN -FOUR BEDROOM 1 1 BA TH UNIT . \2/ EX. ~v·1 0 1 ·-01-+~~ \_~ (D I SEE SHEET />800 FOR _ _L----1[0 p , 1 0 g~ 1 TYP.r;;'\ ® -"\V '=='1:31 "' © M'.-B"A-T-"H~ ~ 11 ~ BEDROOM BEDROOM EX. @( KITCHEN ELEVATIONS 1i7" / O KITCHEN _ . -.:..:J \ '\ '-'1 (:j)@ '---........... r--.. MASTER BEDROOM ....____..f'js'}---, (D LIVING/ DINING -....__-<ISJ----.... l i EX. u BEDROOM '----{'is'}--~ EX. -~ BEDROOM '----''is'\--- EX. ® ~~:;~;:~~D PLAr\J -THREE BEDROOM / 2 BATH UNIT @ DEMOLITION KEYED NOTES: I. 1'1.EMOVE ALL Y'IALLS OR PORTIONS OF Y'IALLS SHOv-lN DASHED. FIELD VERIFY' THAT Y'IALL IS A NON-6EARIN<& Y'IALL BEFORE STARTIN<& v-lORK. NOTIFY ARCHITECT FOR Dl"'-ECTION IF Y'IALL IS A BEARIN<& Y'IALL. 2. REMOVE ALL DOORS SHOv-lN DASHED, INCLUDIN<& ALL HARDY'IARE, ETC. 9. REMOVE ALL KITCHEN CA61NETS, APPLIANCES, PLUMBIN6 FIXTURES, ETC. FIELD VERIFY' v-llTH Ov-lNER. ANY ITEMS THAT NEED TO BE SALVA<&ED FOR 1'1.EUSE. 4. PROTECT EXISTIN6 Y'IATER HEATER AND PIPIN<& DUR.IN6 CONSTRUCTION. 5. REMOVE v-llNDOv-1 AND FR.AME. b. 1'1.EMOVE PORTION OF Y'IALL FOR NEv-1 DOOR., PROVIDE NEv-1 (2) 2xe HEADER. i. PROTECT EXISTIN6 AIR HANDLIN6 UNIT, DUCTv-lORK, PIPIN<& ETC. DUR.IN6 CONSTRUCTION. e. 1'1.EMOVE PLUMBIN6 FIXTU"'-ES FOR 1'1.EPLACEMENT. 'l. 1'1.EMOVE ALL FLOOR.IN6 FOR REPLACEMENT. DEMOLITION NOTES: I. ALI. l"lORK SHALL BE DONE IN ACCORDANCE l'IITH ALL APPLICABLE CODES, l'WLES AND 1<.E..ULATIONS. 2. ALI. DEMOLITION MATERIAL AND ITEMS (UNLESS NOTED TO SAVED) SHALL BE l<.EMOVED OFF SITE AND LE6ALJ. '1" DISPOSED OF. 5TOl'1.A<SE OR SALE OF l<.EMOVED ITEMS ON SITE !'!ILL NOT BE PEl<MITTED. S. P"'-OVIDE INTE"'-IOR AND EXTE"'-IOR SHORING, BRACING, OR SUPPORT TO Pl'1.EVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF STl'WCT\JF<E OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR !'!ORK TO 1'1.EMAIN. 4. 1'1.EMOVE ALL EXISTING FINISH FLOORING AND DAMAGED l'IALJ. BASE TO AL.LOI'! FOR NE[III FLOORING. 5. Pl'1.0TECT F"'-OM DAMAGE EXISTING FINISH l"lORK THAT 15 TO 1'1.EMAIN IN PLACE AND BECOMES EXPOSED DURING DEMOLITION OPEAATIONS. P"'-OMPTL '1" 1'1.EPAIR DAMAGES CAU5ED TO ADJACENT FACILITIES BY' DEMOLITION l"lORK AT NO COST TO Ol'!NE:1'1.. e>. CONDUCT SELECTIVE DEMOLITION OPEAATIONS AND DEBRIS 1'1.EMOVAL IN A MANNER TO EN5Ul'1.E MINIMUM INTERFE1'1.ENCE l'IITI-I !'1.0ADS, 5Tl<.EET5, l'!ALKS, AND OTHE:1'1. ADJACENT OCCUPIED OR USED FACILITIES. i. IF HAZARDOUS MA TE1'1.IAL5 Al'1.E ENCOUNTE:1'1.ED DURING DEMOLITION OPEAATIONS, COMPLY' [1111TH APPLICABLE 1'1.EGULATIONS, L.Al'!S, AND ORDINANCES CONCERNING 1'1.EMOVAL, HANDLING AND PROTECTION AGAINST EXPOSU"'-E OR ENVl"'-ONMENT AL POLLUTION, e. UPON COMPLETION OF DEMOLITION l"<ORK, 1'1.EMOVE TOOLS, EQUIPMENT AND DEMOLISHED MATERIALS F"'-OM SITE. l<.EMOVE Pl'1.0TECTION5 AND LEAVE INTERIOR Al'1.EAS B"'-OOM CLEAN. @ PROPOSED PLAN KEYED NOTES: I. PROVIDE NEv-1 KITCHEN CABINETS, COUNTER.TOPS, APPLIANCES, SINK/FAUCET, AND Ll6HTIN6 FIXTURES AS SELECTED BY Ov-lNER.. PROVIDE NEv-1 c&FIC RECEPTACLES P REQUl"'-ED BY CODE. 2. PROVIDE NEv-1 FULL SIZE STACKABLE v-lASHER/DR.YER. UNITe PROVIDE PLUMBIN6 AND ELECTRICAL HOOK-UPS AS REQUIRED. 5. EXISTIN6 AIR HANDLIN$ UNIT, SERVICE AS REQUIRED. REPLACE AT THE COMPLETION OF CONSTRUCTION. 4. EXIS~IN~ vZ,,~R. ~EA~~ T,; REMAIN, INSPECT AND SERV1d'.' AS 1'1.EQUIRED TO ASSURE PROPER OPERATION. ) '---\1/ 5. NEv-1 INTERIOR. v-lALLS SHALL BE 2x4 v-lOOD STUDS @ lb" Oci ' v-llTH I /2" 6YP. BD. EACH SIDE. USE PRESSURE TREATED s1L ON SLAB, U5E MOISTURE RESISTANT 6YP. SD. IN BATHROOtv AND BEHIND KITCHEN SINK. b. FILL 1~ OPENINc&VF~MVRE~o~D v-ilNDOv-1 v.tTH v,i;oD s~r::\ AND BRICK VENEER TO MATCH EXISTIN6. PROVIDE Y'IALL INSULATION AND VAPOR BARRIER AS REQUIRED. 2 --... & ----;J- i. PROVIDE NEv-1 BATHROOM PLUMBIN<& FIXTURES, Ll6HT FIXTURES, FINISHE5, AND EXHAU5T FAN AS SELECTED BY Ov-lNER B. PROVIDE NEv-1 DOORS AS SELECTED BY OJ/'INER 'i. FILL IN REMOVED DOOR. OPENIN6 TO MATCH EXISTIN<& CONS TR.UC TION. 10. PROVIDE lb" DEEP METAL RACK SHELF $ ROD IN NEv-1 CLOSETS. II. PROVIDE NEv-1 6AR.N TYPE SLIDIN6 DOORS AS SELECTED ["' Ov-lNER 12. FIELD VERIFY EXITIN6 Y'IALL OPENIN6 AND PROVIDE FOR NEv-1 SLIDIN6 DOOR EP6E TO ED6E. 15. PROVIDE NEv-1 FLOOR.IN6 AND v-lALL BASE AS SELECTED B Ov-lNER. 14. INSTAL,.L--...NE,,..v-l-.,,,VTU.-----.6,,..--$.,,, VT-IL'E---v-i'Av""L'-.L,,..S_SU.,..RR"·.,,.o-u'vN"~D-,..,,.c-A"u~L---1<.,,.A~S~RE-vraQ' TO v-llNDOv-1 FR.AME. PROVIDE 'DAL TILE' 5"xb" CERAMIC ~- TILE, BR.16HT v-lHITE. • • . ------& & ~-\3/ 15. PROVIDE NEv-1 100 CFM CEILIN6 MTD. EXHAUST FAN, DUCT ' v-llTHIN NEv-1 SOFFIT ALON6 v-lALL AND UP THROU6H CHASE 0 ROOF. lb. REMOVE NC RE61STER. THAT FALLS INTO CLOSET AND COM61NE CFM CAPACITY v-llTH BEDROOM RE61STER.. MODlf DUCTv-lORK AND REPLACE RE61STER. AS REQUIRED. Ii. REMOVE A/C RE61STER. IN SOFFIT OVER SINK AND MOVE ·:Y· Y'IALL OVER NEv-1 KIT. ISLAND. MODIFY DUCTv-lOR.K AS 1'1.EQUIRED. lel. PROVIDE NEv-1 LED Y'IALL SCONCE AS SELECTED BY Ov-lNEF v-llTH SJ/'IITCH ADJACENT TO BEDROOM ENTRANCE DOOR c.o ....... N I-00 r-- en (._) p 0::: w 0 I-w --:z $ :::c 0 (._) I- 0 :z a... 0::: <( <( :z • <( _J I-en >-(._) -:::::s:::: ~ w C> ~ --, ~ 0 -0 --, 0::: C> a... LO C"') 0 N ~1/ --' en u.. -z en UJ 0 --' I---' --> I-z :z ~ w 0 ~ en :::::s:::: 0 I-C> <( z 0::: ...., w <( I 0::: a... . I-<( 0 > z w --' co w Cl C> ~ --en I- I-:z 0::: <( ::5 w <( en ~ a... LO <( 00 0 ....... I --:~t===tl ==========:I --+---+----------11 I ~-f------ll----------11 I 2 3.13.2020 REV. AS PER OWNER _1 . 3.5_).Q_2.Q_LR~-BATHROOM Wlt-100'/f REV DATE DESCRIPTION ISSUE DATE: 11.05.19 PROJECT NUMBER: 63919 DRAWN BY: JD CHECKED BY: CG Copyright (c) by C.G.A, LLC. All Rights Reserved. SHEET TITLE: DEMO & FLOOR PLANS. SHEET NUMBER: A100 ELECTRICAL GENERAL NOTES: AS APPLICABLE I. PROVIDE COMPLETE 5Y5TEM5 A5 DEFINED ON PLAN5 AND/OR A5 REQUIRED. ALL i"lORK 5HALL COMPLY V'llTH THE NATIONAL ELECTRIC CODE, ANY LOCAL CODE5, AND ALL UTILITY REQUIREMENTS. ELECTRICAL CONTRACTOR 5HALL PROCURE AND PAY FOR ALL REQUIRED PERMITS AND UTILITY CHAR6E5. 2. CONTRACTOR 15 RE5PON51BLE FOR Yl51TIN6 THE 51TE PRIOR TO 5UBMl5510N OF BID5 TO INSPECT EXl5TIN6 CONDITIONS. NO EXTRAS i"llLL BE ALLOV'lED AFTER Ai"lARD OF THl5 CONTRACT FOR EXl5TIN6 CONDITIONS. 9. ALL ELECTRICAL i"lORK 5HOV'lN AND REQUIRED 5HALL BE BY TENANT'S ELECTRICAL CONTRACTOR UNLE55 OTHERY'll5E STATED AND 5HALL INCLUDE, BUT 15 NOT LIMITED TO THE FOLLOV'llN6, CONDUIT, i"llRE, Dl5CONNECTIN6 MEAN5, 5i"llTCHE5, RECEPTACLES, JUNCTION BOXE5, BREAKERS, LABOR, COORDINATION, ETC. 4. THESE DRAV'llN65 ARE DIA6RAMMATIC AND ARE NOT INTENDED TO 5HOV'l EXACT LOCATIONS UNLE55 DIMENSIONED. COORDINATE V'llTH HYAC, PLIJMBIN6 AND FIRE PROTECTION TRADES. COORDINATE LOCATION OF ALL ROU6H-IN'5 JIIIITH ARCHITECTURAL DETAILS. PROVIDE ALL REQUIRED ELECTRICAL 5ERYICE5. 5. ALL BRANCH CIRCUIT DEVICES ARE TO BE NEV'l, U.L. LISTED. AND OF THE FOLLOV'llN6 RATIN65, 5V'llTCHE5-l20/2ii Y.A.C., 20A; DISCONNECT 5JIIIITCHE5-A5 REQUIRED; ALL AALL PLATES SHALL BE TYPE AND COLOR A5 SELEG TED BY ARCHITECT/OJIIINER. 6. ALL EQUIPMENT 5HALL BE NEV'l, U.L. LISTED, COMMERCIAL 6RADE AND JIIIEATHERPROOF IF EXPOSED TO i"lEATHER. i. THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY 6UARANTEE Hl5 i"lORKMAN5HIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF COMPLETION. MAKE NECE55ARY REPAIRS AT NO COST TO Oil'INER. 8. ALL BRANCH CIRCUIT il'IIRIN6 TO BE 2 # 12, COPPER, IN 9/4" C. UNLE55 OTHERY'll5E NOTED. PROVIDE FULL 51ZE 6ROUND il'IIRE FOR ALL BRANCH CIRCUITS. TYPE THHN OR THll'IN il'IIRIN6 15 TO BE UTILIZED. ALL il'IIRIN6 SHALL BE CONCEALED UNLE55 5PECIFICALL Y APPROVED BY THE ARCHITECT. "I. THE EXl5TIN6 ELECTRICAL SERVICE 15 TO BE MAINTAINED. VERIFY EXl5TIN6 EQUIPMENT, FEEDERS, AND CONDITIONS PRIOR TO 5UBMl55ION OF BIDS. 10. PROVIDE ANY REQUIRED CIRCUIT BREAKERS IN EXl5TIN6 PANELS TO M!':!':T N!':i"l BRANCH CIRCUIT REQUIR!':M!':NT5. II. REMOVE ALL EXl5TIN6 ELECTRICAL EQUIPMENT, FIXTURES, 5Y5TEM5, CONDUIT AND il'IIRE ETC. NOT BEING, REUSED (UNLE55 NOTED). DO NOT JU5T ABANDON. MECHANICAL GENERAL NOTES: AS APPLICABLE I. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LABOR ANl? MATERIALS TO PROVIDE A COMPLETE ANl? 1"40RKIN6 5Y5TEM. ALL ViORK SHALL COMPLY VilTH THE 5TATE MECHANICAL CODE, ANY LOCAL CODES. MECHANICAL CONTRACTOR SHALL PROCURE ANl? PAY FOR ALL REQUIREP PERMITS. 2. ANY NEVi DUCTViORK SHALL BE CONSTRUCTED AND INSTALLED PER ASHRAE ANl? SMACNA STANDARDS AND THE STATE MECHANICAL CODE. 5. ALL DUCTil'IORK SHALL BE CONSTRUCTED OF ,S,ALVANIZED SHEETMET AL. 4. REPLACE ANY MISSING, OR DEFECTIVE INSULATION. S. PROVIPE FIRE RESISTANT TYPE FLEXIBLE PUCT CONNECTORS ON THE INLET ANl? DISCHAR6E DUCT CONNECTIONS OF ALL EQUIPMENT CONTAINING, FANS. 6. CONDENSATE DRAIN PIPING SHALL BE TYPE "L" OR "M" HARD PRAViN COPPER VilTH ViROU,S,HT COPPER FITTIN,S,S. INSULATE CONl?EN5ATE PIPING, VilTH I" THICK FIBER,S,LA5S VilTH ASJ OR 1/2 ARMAFLEX. PLUMBING GENERAL NOTES: AS APPLICABLE I. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LABOR AND MATERIALS TO PROVIDE A COMPLETE AND il'IORKIN,S, 5Y5TEM. ALL l'lORK SHALL COMPLY VilTH THE STATE PLUMBING, CODE, ANY LOCAL CODES. MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL REQUIRED PERMITS. 2. AASTI:, DRAIN AND VENT PIPING, SHALL 6E SCHEDULE 40 FOAM CORE DY>!V PIPE COMPLYING Y>!ITH ASTM F8ql Y>!ITH SCHEDULE 40 PVC FITTINGS. 9. A60VE GROUND POTA6LE AATl:R PIPING SHALL 6E TYPE CFVC SCHEDULE 40 Y>!ITH SCHEDULE 40 CFVv FITTINGS. 4. INSULATI: HOT, COLD, AND CONDENSATI: PIPING i'llTH I" THlvK Oi'lENS CORNING, Fl6ERGLASS 55!.II, OR APPROVED EQUAL INSTALLED FER MANUFACTUFI.EFl.5 REQUIREMENTS. INSULATION SHALL SE vONTINUOUS THROUGH i'lALLS, FLOORS, CEILINGS, ETC. 5, PROVIDE SHUTOFF VALVES AT INLET OF EACH PLUM61NG EQUIPMENT IT!:M, AND AT INLET OF EACH PLUM61N6 FIXTURE, AND ELSEl'lHERE A5 REQUIRED. &. THE DOMESTIC AATl:R PIPING> SYSTl:M SHALL 6E ST!:RILIZED PER HEALTH CODE. 1. UPON COMPLETION OF PIPING> INSTALLATION, ENTIRE SYSTEM SHALL 6E THOFI.OU6HLY FLUSHED OF ALL FOREIGN MATl:RIAL. PIPING SHALL 6E HYDFI.OSTATlvALL Y Tl:STED AT 100 P516 FOR Ti'lO HOURS AND SHALL SE i'llTNE55ED SY THE OViNERS REPRESENTATIVE. 8, INSTALL CLEANOUT5 IN DRAIN PIPING> AS REQUIRED 6Y ALL PLUM61NG CODES, AT EAC,H vHAN6E IN DIREvTION OF PIPING> 6REATl:R THAN 4S DEG>, AND AT 6A5E OF EAC,H C,ONDUC,TOR, INSTALL FLOOR AND AALL CLEANou· COVERS FOR CONvEALED PIPING>, SELECT TYPE TO MATC,H ADJACENT 6UILDING FINISH /VERIFY SELEvTION Y>!ITH Oi'lNER PRIOR TO ORDERING>J. q_ PROVIDE vHROME ESCUTvHEONS i'llTH SET SCREl'l, DEEP TYPE, TO COVER SLEEVES OR OF A SIZE TO COVER FITTING PFI.OJEC,TIONS. PROVIDE ESCUTCHEONS FOR ALL FOR ALL EXPOSED PIPING THROU6H i'lALLS AND FLOORS. 10. MINIMUM SLOPE OF HORIZONTAL MST!:, VENT, AND STORM LINES TO 6E 1/4" PER FOOT. APARTMENT ITEM LIST: Item Description Quantity Internet SKU# Model Light Switches (lOpk) 20204204 Three-way Switches 203737026 CA-3PS-WH Switch Covers (Single) (lOpk) 100356780 M52-0PJ26-0WM Switch Covers (2-Gang) 100356912 R52-P J262-00W Switch Cover (3-gang) · 203492609 P J263W-SP-L Switch/Blank Cover 301701277 80708-W Outlets (lOpk) 100684055 Outlet Covers (lOpk) 100356780 M52-0P J26-0WM GFCI Outlet (4pk) 305340161 M42-GFTR1-04W Cable Jack 203717887 Phone Jack 202698769 76197 Deadbolt 202099363 Passage Door Knob (6pk) 1002708057 Privacy/Bath Door Knob 305049639 Dummy Knob 309724945 32TGX240B Smoke Detector 300228968 Hinges (12pk) 202045487 Bifold Door Knobs 202023241 P11747V-SN-C Toilet (with seat) 100676582 N2316 Ceiling Fan 300937534 AG524-BN 18" Ceiling Fan Downrod 206432683 QC0336025 36" Ceiling Fan Downrod 100075313 26022 Shower Bar 202043924 CSR2160BN Bath Light Fixture (4 Light) 202352118 HB2077-35 Closet/Kitchen Light 206748716 EVLED502-35 Wall Sconse 202022515 X124501 Light Bulbs (16pk) 206200382 52698 Showerhead 205739880 N2920CH Drip Pans (1 set of 6" & 8") 307638925 Thermostat 309440676 RTHLlllBlOOl/Kl Bath Light Fixture (3 Light) 202352121 HB2076-35 Door Stops (5pk) 301015627 15580 Harbor Grey (5 Gallon) (Sandy) Trim Paint (1 Gallon) (Sandy) Paint (Ceiling) (Sandy) 36x80 (Jeld-Wen Two Panel) 202084013 THDJW1370D0551 30X80 (Jeld-Wen Two Panel) 202205186 TWDJW137000550 28X30 (Jeld-Wen Two Panel) 202205185 TWDJW137000549 24x30 (Jeld-Wen Two Panel) 202205184 TWDJW137000548 GENERAL NOTES: I. ALL i"lORK ON THl5 PROJECT 5HALL BE IN ACCORDANCE i"llTH ALL CODE5, 5UB-CODE5 AND BUILDING, DEPARTMENTS AND HEAL TH DEPARTMENTS, IF APPLICABLE HAYING, JURISDICTION. 2. ALL RULE5 AND RE6ULATION5, 5COPE OF i"lORK AND PROCEDUR.1;5 INDICATED il'IILL BE PERFORMED BY THE 6ENERAL CONTRACTOR, THEIR A6ENT5, 5UBCONTRACTOR5, AND 5UPPLIER5 TO PROVIDE A TOTAL AND COMPLETE PROJECT FOR THE Oi"lNER. i"lORK 5HOll'IN IN THESE NOTES 15 TO BE PERl"ORMED BY THE 6ENERAL CONTRACTOR OR 5UBCONTRACTOR5, A6!':NT5 AND / OR 5UPPLIER5 ONLY, i"lHETHER Of<. NOT THE i"lORK 15 DELINEATED PROPERLY. 9. THE 6ENERAL CONTRACTOR AND THE 5UBCONTRACTOR5 FOR THE 6ENERAL CONTRACTOR 5HALL PAY FOR AND OBTAIN ALL. PERMITS REQUIRED FOR THE il'IORK NOTED ON THESE PLAN5. 4. QUALITY 5TANDARD5, ALL 5UCH i"lORK SHALL BE PERFORMED IN A FIR5T-CLA55 il'IORKMANLIKE MANNER AND SHALL BE IN 600D AND USABLE CONDITION AT THE DATE OF COMPLS:TION THEREOF. 6ENERAL CONTRACTOR SHALL REQUIRE ANY PERSON PERFORMING, ANY SUCH i"lORK TO 6UARANTElll THE 5AME TO BE FREE FROM ANY AND ALL DEFECTS IN i"lORKMAN5HIF AND MATERIALS FOR ONE (I) YEAR FROM THE DATE OF 155UANCE OF THE CERTIFICATE OF OCCUPANCY. Oil'INER 5HALL AL50 REQUIRE ANY 5UCH PERSON TO BE RE5FON516LE FOR THE REPLACEMENT OR REPAIR il'IITHOUT ADDITIONAL CHAR6E, OF ANY AND ALL i"lORK DONl;c OR FURNISHED BY OR THROU6H 5UCH PERSON, i"lHICH 5HAL.L BECOME DEFECTIVE il'IITHIN ONE (I) YEAR AFTER COMPLETION OF THE i"lORK. THE CORRECTION OF SUCH i"lORK SHALL INCLUDE, il'IITHOUT ADDITIONAL CHAR6E, ALL EXPEN!aE'5 AND DAMA6E5 IN CONNECTION il'IITH 5UCH REMOVAL, REPLACEMENT OR REPAIR OF ANY PART OF THE il'IORK il'IHICH MAY BE DAMA6ED OR DISTURBED THEREBY. ALL il'IARRANTIE5 OR 6UARANTEE5 A5 TO MATERIALS OR il'IORKMANSHIP ON OR il'IITH RE5PEC T TO THE il'IORK 5HALL BE CONTAINED IN THE CONTRACT OR SUBCONTRACT i"lHICH SHALL INURI: TO THE BENEFIT OF THE Oil'INER. 6ENERAL CONTRACTOR TO HAYE THIS CLAUSE IN EVERY SUBCONTRACTOR A6REEMENT FOR THE PROJECT AND IF SUCH CLAUSE 15 NOT INCLUDED, IT il'IILL NOT RELIEVE THE 6ENERAL CONTRACTOR OF THE REQUIREMENTS OR il'IORK STATED HEREIN. 5. ALL FINISH AND EXPOSED V'lOOD 5HALL BE KILN DRIED, MILL QUALITY FINISH AND SHALL RECEIVE A FIRE RETARDANT COATIN6 OR TREATMENT IF REQUIRED BY CODE OR THE LOCAL FIRE MARSHALL. PROVIDE ADEQUATE NUMBER OF FA5TENIN6 AND FINISH NAILIN6. RECE55, FILL, AND 5AND ALL FINISH NAIL5 TO RECEIVE PAINTIN6. CAULK TRIM TO il'IALL AND FLOOR FINISHES A5 REQUIRED TO ELIMINATE ANY 11GAPS11 6. ALL 6YP5UM BOARD TO BE 1/2" THICK, /AATER RE515TANT IN TOILET ROOMS). PROVIDE 5/8" TYFE 'X' FIRECODE 6YP5UM BOARD ON ANY FIRE/DEMl5IN6 AALL5, OR i"lHERE REQUIRED TO MATCH EXl5TIN6. i. ALL 6YP5UM BOARD TO BE TAPED AND 5PACKLED THREE (9) COATS, SANDED AND READY TO RECEIVE FAINT OR i"lALL COVERIN6. ALL EXl5TIN6 $YP5UM BOARD OR PLASTER TO BE REPAIRED TO "LIKE NEV'l" CONDITION. 8. ALL THE FL.OOR FINl5HE5, i"llTHIN THE PREMl5E5, OR AT THE TRANSITION BETll'IEEN EXl5TIN6 AND NEll'I FLOOR FINl5H!':5 ARE TO Bia SMOOTH AND LEVEL TO AVOID TRIPPING, HAZARDS AND BE il'IITHIN THE REQUIREMENTS OF BARRIER FREE DE510N. IF THE EXl5TIN6 5LA65 ARE NOT LEVEL, THE 6ENERAL CONTRACTOR 15 REQUIRED TO COMPLETE EXTENSIVE FLASH PATCHING, THROU6HOUT TO OBTAIN A SMOOTH AND LEVEL CONCRETE 5LAB. "I. THE 6ENERAL CONTRACTOR 15 RESPONSIBLE FOR FURNl5HIN<:> AND IN5TALLIN6 ALL TOIL!':T ACCE550RIE5, A5 il'IELL A5 THE NEV'l TOILET ROOM. 10. THE MECHANICAL AND PLUMBING, 5UBCONTRACTOR5 ARE RE5PON51BLE FOR Yl51TIN6 THE 51TE PRIOR TO 5U6MITTIN6 A BID FOR THE JIIIORK ON TH15 PROJECT. THE CONTRACTOR MUST BECOME FAMILIARIZED il'IITH THE FIELD CONDITION5, AND THE SCOPE OF i"lORK. EQUIPMENT, fRIM, AND FINISH NOTES: NO SUBSTITUTIONS ALLtWED WITHOUT OWNER WRITTEN APPROVAL: 6ENERAL I. LEVEL AND PATCH E>eTIN6 FLOORS A5 REQUIRED FOR NEll'I FLOORING,. 2. REMOVE EXl5TIN6 -p.pYIDE LIFEPROOF VINYL PLANK FLOORIN6 THROU6Ho[i/AYAILABLE AT THE HOME DEPOT). COLOR -5TERLIN6 oil(. 9. PROVIDE FAUX i"lOOD3LIND5 FOR ALL i"llNDOi1'15. 4. V'llNDOil'I 51LL5-REMOl:i TILE AND ADD NEll'I V'lOOD i"llNDOV'l SILL. 5. REPLACE ALL EXl5TINcil'IITH NEV'l SMOKE DETECTOR, MATCH EXl5TIN6 TYFE. 6. PROVIDE NEll'I lx4 li'IO@ BASEBOARD, PTD. THROU6HOUT. 1. PROVIDE ALL NEV'l lx:'J"IOOD CA5IN6, PTD. AT ALL DOOR5 AND i"llNDOil'l5. 8. PROVIDE NEll'I VENTEr::DOOR FOR MECHANICAL CLOSET. "I. CHAN6E TO ALL Ll6H,FIXTURE5 TO LED Ll6HT5 IN A BRUSHED NICKEL FINIS' KITCHEN: I. PROVIDE NEll'I 5HAKEfsPTYLE BA5E AND AALL CABINETS i"llTH 50FT CLOSE HINGC5 AND BAR5TYLE PULL HARDAARE. 2. INSTALL NEV'l ABOVE f!-N6E MICROAAYE. 9. INSTALL NEV'l Dl5HAAsJ=R. 4. INSTALL NEV'l REFRl6EA TOR. 5. INSTALL NEll'I OVEN/4J~RNER RAN6E. \l7-6. N O T U 5 E D. i. ALL APPLIANCES sH,"/c BE 5TAINLE55, SUPPLIED BY Oi"lNER. 8. PROVIDE NEV'l FULL H~HT CABINETS il'IITH CROV'lN MOLDING, TO MEET CEILIN6. "I. PROVIDE NEV'l BUD6E·pRANITE OR QUARTZ COUNTERTOP5 - BLACK OR DARK 6Rf. COLOR. 10. PROVIDE NEV'l BACK5r-A5H -il'IHITE 5UBll'IAY TILE. II. REPLACE ALL 6FCI 6TLET5. BATHROOMS \1~ I. REMOVE EXl5TIN6 -p.pVIDE NEV'l TUB -'BOOTZ INDUSTRIES' ,, "ALOHA bO", LEFT HA!< DRAIN, il'IHITE (AVAILABLE AT THE HOME DEPOT), INCLUDl6 CERAMIC TILE il'IALL5 SURROUND. 2. PROVIDE NEV'l 9-PIEC£YORNER 5HOV'lER A5 MF6. BY DELTA /AVAILABLE AT THE 8ME DEPOT) BASE-MODEL #6ill'iii38::l8 -V'!HITE, AALL5-MODEL #66i"ll,se,9e-i"lHITE, FRAMELE55 CORNEFPOOR-MODEL #6"111"111-9898-55 9. PROVIDE NEV'l 51N6LEiANDLE DIYERTER / MIXING, VALVE. 4. PROVIDE NEV'l YANln/5HAKER 5TYLE, V'lHITE FINISH). 5. PROVIDE NEV'l BATHR.if'M HARDAARE-TOil'lcL. AND 50AP HOLDER. 6. NEV'l 6FCI OUTLET Mn::@ 42" AFF. 1. PROVIDE NEV'l il'IATER>AYIN6 TOILET INCLUDING, 51.JPPLY LINE -il'IHITE FINISH. DOORS AND HARJIAIARE, I. ALL INTERIOR DOORef'O BE CHANGED TO ONE PANEL SHAKER 5TYLE. 2. HARDAARE TO BE Cl'fJ'l6ED TO BRUSHED NICKEL INCLUDING, HANDLE, HIN6E5, AND700R 5TOP5 /ADD IF NOT PRESENT). FAINT I. PATCH AND REPAIR j,,!Y HOLES OR OLD REPAIRS. 2. REPAIR KITCHEN CEIIL'"" TO UNIFORM TEXTURE. 9. PAINT ALL i"lALL5 V'lli:BEHR MARQUEE 5ATIN SILVER MINE OR DRIZZLE 6RAY. 4. TRIM TO BE SANDED ·o UNIFORM AND FAINTED il'IITH SEMI 6L055 il'IHITE. 5. CEILIN65 SHALL BE p)NTED i"lHITE. 6. PAINT ALL CLOSET 5j:LYIN6 il'IHITE. MECHANIC.AL I. CLEAN ALL EXl5TIN6~615TER5, 6RILLE5, ETC. 2. VERIFY THERMOSTATS IN PROPER i"lORKIN6 ORDER, REPAIR OR REPLACf:~5 REQUIRED. 9. REPLACE FIL TER5 A1THE COMPLETION OF CONSTRUCTION. FLUMBIN6 I. PROVIDE ALL FIXTUf<.?, FIPIN6, FITTIN65, ETC. FOR NEV'l BATHROOM AND RENifATED KITCHEN t BATHROOM. ELECTRIC.AL I. REMOVE ALL i"lALL 5'jTCHE5, RECEFTACLE5, AND PHONE/ DATA OUTLETS AND FPLACE il'IITH DECORA DEVICES - i"lHITE FINISH. 2. U5E "ALUMICONN" cotlJ=CTOR5, Nb\CE TO CONTRACTORS: ALL @NTRACTOR5 PRIOR TO BID SUBMISSION PROCESS SHALLYISIT PROPOSED l'lORK SITE AND FIELD VERIFY ALL l'::ISTIN0 CONDITIONS. ANY GONDITION THAT DIFFERS FROt-THAT SHOl'lN ON THESE PLANS SHALL BE REPORTED TO Ti':TENANT'S ARGHITECT/EN&INEER SO THAT NEl'l AND REVl\'P BID DRAl"llN0S OR INFORMATION MAY BE ISSUED. MODIIGATIONS TO THE SCOPE OF l"lORK l"lHICH RESULTS FROtTHE GONTRAvTORS NE0LEGT TO VISIT THE SITE PRlorTO SIJBMITTIN0 BID, SHALL BE THE GONTRACTORS 501£'..ESPONSIBILITY. U) 0::: w $ 0 a_ --:, U) z: 0 -I- ~ 0 z: w 0:: I-z: w :2: I- 0::: <( a_ <( t; w I--:c (._) 0::: <( I- (._) w -:, 0 0::: a_ (0 ....... N 00 r-- ~ 0 -z 0 1-z <( z <( en -~ (.) ~ 0 (.) LO M C> N /A ......I u.. - U) w ......I I-......I -> z: z w 0 :2: en ~ I-(.) <( 0::: --:> <'( I a_ . <( 0 :::j w cc Cl (.) --U) I-:z: <( <( w ......I U) ~ LO 00 C> ....... I 1-,_L_ ___ ---~--------111 -----~-----~----Ill ~-~""--+------------ 'iil-v•· 3. n.2020 REV. AS PER OWNER ro; . DATE: D RIPTIMN ISSUE DATE: 11.05.19 PROJECT NUMBER: 63919 DRAWN BY: JD CHECKED BY: CG Copyright (c) by C.G.A, LLC. All Rights Reserved. SHEET TITLE: EQUIPMENT LISTS AND NOTES SHEET NUMBER: A200 ~ --" co ....- N -00 r~ V V V ' V V V V V V V V V V V . . . . . . . . . V V V V V V V V V V V V V V V V V V V V . . . . . . V V V V . . . V V V V V V V 'i I-....... ' u p 111-011 51-611' • U) ' • 0::: w - ' 0 • I-w -' ::z: • - ' ~ :c 0 • ' u I- • 0 ::z: / "'-7 ' , ' / "'-w/4 'w£ ~: a\ I / "'-0::: <( /, "' \ /v E,ias w'3s • a.. • 3b: / \3ll ' 3 3 / I 3'2 ' / ' ' ' <( ' / n / ' n ' ::z: "'-H / I "'-/ I/ ~ " X X j , "'-/ • <( ' \ " ,, ......J I/ i\ ' I-en ' / ' \i "' / ii I \ I \ \ \i ' >-u I I/ - ' :::is:::: . ' ' ' -~ ~ w (..) ' 11-011 ' - ' j ;:., ~ ---:, ~ w I ' 0 ·' ' ,... ~ ,... I • -0 ---:, 0::: ' (..) ~ ' ' = I= @@1 -' I ' J 1= @@I = = = a.. ~ I "-LO " / " / " ' / ' //I '7 -C"? / I I ~ / n ~ / I I ~ I ('' ' ~ " X b S' X \ b / ' / / ) I/ _, , _, / ) ' B12 ' 3 DW24 S36/ <fl m S31/ (0 ' s: 0 / i:o ,, s: 4 • REFRIG I " / " B B.I.OVEN r ' ' ~ / ~ / ~ / ' / . ' • .. / ' / ' ----"> / Ill ' • ' 0 --fl ·~ • SEALO ?'--~ ~---~~() 1 ' ~'fA.,~---·t~-~ '» ' ' p I>) .•;i,,-l. ' :i'? JJ , '" .,. ' "' * :~'o/i ."p·,. ,lr J ' ~ :::, -* -''': . 1 ' ' ~ ~ \ .6.HOO 7748 / ,0 :J • , . . ,!,J., ' CD ~l~~~l~O"ELEVATION (q) SINK WALL ® ~l~~~l~O"ELEVATION ® OVEN WALL ® ~l~~~l~~ .. ELEVATION ISLAND CA31NETS 0 Q ··.. .... f~ <fl' @l • I ,...& ••• ..· ,_-.,, ,,, ,, l-i""••········ """'.,. , .Iii 1:t" .,. • 1, fD t-:·_: , ''"'"'"''"-» ' , ' , ,w ' - . . . . . . . . . . . . . . . -. -. -. -. -. -. . . . . -. . . . . . . . . . . -. . . ---. . . . . . . . . . . -' . . . . . . . - .....J U) LL -:z CJ) w 0 .....J .....J I---> ~ :z ::z: w 0 ~ en :::is:::: 0 I-(..) <( :z 0::: -, w <( I 0::: a.. . I-<( 0 > :z w .....J co w Cl (..) ~ --U) I- I-<( ::z: 0::: <( w .....J <( U) ~ a.. LO <( 00 C) ....- - -- ···----·--I I I ·~··--·-·-·· -+ ·-· ______ ,, I I I I I I I I I I I . . ----..... ,_._ --·-- 1 3.13:ilfzQ jREV. A5 PER OWNER ornc· -DESCRIPTION --·-·-~··· ISSUE DATE: 11.05.19 PROJECT NUMBER: 63919 DRAWN BY: JD NOICE TO CONTRACTORS: CHECKED BY: CG ALL QNTRACTORS PRIOR TO BID SUBMISSION PROCESS Copyright (c) by C.G.A, LLC. All Rights Reserved. SHAUVISIT PROPOSED WORK SITE AND FIELD VERIFY SHEET TITLE: ALL j(ISTIN0 CONDITIONS, ANY CONDITION THAT DIFFERS FROtvTHAT SHOWN ON THESE PLANS SHALL BE REPORTED KITCHEN PLAN TO TF. TENANT'S ARCHITECT/EN&INEER SO THAT NEW AND REVl§D BID DRAWIN&S OR INFORMATION MAY BE ISSUED. AND ELEVATIONS MODi\CATIONS TO THE SCOPE OF JAlORK WHICH RESULTS FROl'THE CONTRACTORS NE6LECT TO VISIT THE SITE PRIOFJO SUBMITTIN0 BID, SHALL BE THE CONTRACTORS SHEET NUMBER: SOLE<l=SPONSIBILITY. A300