Loading...
490 Levy Rd ROW20-0026 right of way permitOWNER:ADDRESS:CITY:STATE:ZIP: MS TRACT LLC 1059 MIMOSA COVE CT E ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: Lee Engineering & Construction P.O. Box 69-8406 Valdosta Hwy Dupont GA 31630 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171074 0000 ATLANTIC BEACH SEC H JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 490 LEVY RD UNIT 1 RIGHT OF WAY SINGLE OR TWO FAMILY RIGHT OF WAY approx. 660-ft. directional boring for fiber optic cable $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 9/17/2020 PERMIT NUMBER ROW20-0026 ISSUED: 9/17/2020 EXPIRES: 12/16/2020 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS UTILITY ROAD CUT INFORMATIONAL Notes: Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the plans.\r\r\r\r\r\r 5 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 6 PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 7 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: 2 of 2Issued Date: 9/17/2020 PERMIT NUMBER ROW20-0026 ISSUED: 9/17/2020 EXPIRES: 12/16/2020 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 APPLICATION REVIEW AND TRACKING FORM Property Address: ______________________________ Applicant: ____________________________________ Project: _______________________________________ Review fee $________________ Dept Signature __________________ APPLICATION STATUS Reviewing Department (Circle one.) BUILDING PLANNING & ZONING TREE ADMIN. PUBLIC WORKS PUBLIC UTILITIES PUBLIC SAFETY FIRE SERVICES First Review: Approved. Denied. Not applicable Comments: Reviewed by:__________________________ Date:______________ Second Review: Approved as revised. Denied. Not applicable Comments: Reviewed by:__________________________ Date:______________ Third Review: Approved as revised. Denied. Not applicable Comments: Reviewed by:__________________________ Date:______________ Revised 05/19/2017 Department review required Yes No Building Planning & Zoning Tree Administrator Public Works Public Works Public Utilities Public Safety Fire Services Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: _________________________________ City of Atlantic Beach Building Department 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone (904) 247-5826 · Fax (904) 247-5845 E-mail: building-dept@coab.us City web-site: http://www.coab.us APPLICATION NUMBER (To be assigned by the Building Department.) ________________________ Date routed: _______________________ PUBLIC UTILITIES PLAN REVIEW COMMENTS Date: Application #: Project Address: APPLICATION TRACKING COMMENTS Check Box to Add Comment Check Box to Print Underground Water Sewer Utilities Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5878.   Meter Boxes Sewer Cleanout Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible.   RT1 Sewer Cleanout A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible.   RPZ Backflow A reduced pressure zone backflow preventer must be installed if irrigation will be provided or if there is a private well on the property. Backflow preventer must be tested by a certified tester and a copy of the results sent to Public Utilities.   Sensus Touch-Read Meter Plans note the building will be unsprinkled. If plans change, any fire line installed must be metered with a Sensus touch-read meter in a properly sized vault and an appropriate backflow preventer installed. Backflow preventer must be tested by a certified tester and a copy of the results sent to Public Utilities.   Fire Sprinkler Backflow Requirement If fire sprinkler system is provided, call 247-5878 for backflow requirements. At a minimum, will require a double check backflow preventer.   Fire Line Meter Fire lines must be metered with a Sensus touch-read meter. Meters larger than 2” must be installed in a vault as noted in JEA specifications.   Utility Map See attached Utility Map.   Disconnect & Cap Disconnect and cap water and sewer lines.   Inspection Prior MUST call the Inspection Line at 247-5814 to request an inspection of the disconnected and capped water and sewer lines PRIOR to demolition.   Utility Inspections All water & sewer utility connections must be inspected prior to cover up. Please call the inspection line at 247-5814 to schedule inspections 24 hours in advance. Failure to schedule utility connections may result in failed inspections and additional fees, and delays in utility services.   System Development Fees All fees must be paid for water & sewer connections before meters will be set. Please call the finance department customer service line 247-5816 to coordinate payment of fees.     AUGUST 24, 2020APPROVED:HAPPY TRAILS 4X4 ATLANTIC BEACH#490 LEVY ROAD - ATLANTIC BEACH, FLFIBER OPTIC INSTALLATIONPLANS FOR PROPOSED PROJECT:AERIAL FIBERUNDERGROUND FIBEREXISTING VICINITY MAPFERNANDINA BEACHATLANTIC BEACHJACKSONVILLEPONTE VEDRA BEACHJOB INFORMATIONDATE:JOB #UNDERGROUND CONDUIT:AERIAL:TOTAL FIBER:CPE-419480EST - 666' / ACT - EST - 0' / ACT - EST. - 966' / ACT. - RPROJECT LOCATION08/20/20 HAPPY-1 UNDERGROUND - LEVY RDBOB MENSCHING - (904) 718-8152TRAVIS GEORGE - (251) 487-7225TABITHA WELCH - (251) 391-3240ASHLEY BAKER - (251) 402-0066CONTACT LISTAS-BUILTDESCRIPTIONDWG. NAMEDIRECTORYATTENTION PERMITTING DEPARTMENTPROJECT MANAGER:ENGINEER:PROJECT CONTACT:CPE LOCATION: HTTPS://UNITI.MY.SALESFORCE.COM/A083X00001C88JDEND PROJECTBEGIN PROJECT 2'4'5'3'1'6'0'7'8'9'2'4'5'3'1'6'0'7'8'9'DWG. NO:DRAWN BY:DATE:CONTACT Southern Light: 877-652-2321DATE:REVISIONSINDEX REF.:SCALE:VERSION:SPLICE DWG.:PROJ. NO.:ENG: ALL UTILITY LOCATIONS SHOWN ARE APPROXIMATE.CONTRACTOR IS RESPONSIBLE FOR ALL LOCATINGPRIOR TO ANY WORK PERFORMED.office: 251.662.1170 fax: 251.662.1297107 St. Francis St. - Suite 1800Mobile, AL 36603www.slfiber.comATLANTIC BEACH, FL#490 LEVY ROADDEPTH TO BE A MINIMUM OF 60" BELOW GRADE2 - 1.25"HDPE5' MIN FIBERCABLE- EOP5+21 - EOP5+47 PULL FIBERDIR. BORE 2-1.25"- 0+00 EX. HH/BORE PIT - PLACE MMP HH6+66PROPOSED HDPEBELOW GRADESPEEDLIMIT25EST = 966'EST = 666'EOPC/LROWEOPEOPROWROWC/LEOPEOP54' 27' 27' 24' 15' 15' 12' 12'SPEC SHEET150' SLACKPL. H.H.ROW2'13'2-1.25" HDPE144ct FIBERNOTE:SOUTHERN LIGHT HAS LOCATED ALL EXISTING UTILITIES.AN EXTENSIVE LOCATE WILL BE PERFORMED PRIOR TO CONSTRUCTION.SOUTHERN LIGHT WILL MAINTAIN 18" FROM EXISTING UTILITIES.NO BACK REAMER REQUIRED DUE TO SIZE OF 4" BIT.5'15'GROUNDPROPOSED DUCT13'ASPHALT SURFACE36"x24"x36"150' SLACKEXIST. H.H.2' 13' MMP - PED6+54 - PED6+46 S- SEWER MH5+38S WTR WTR WTR WTR WTR WTR WTR- WATER LINE5+14W- END FENCE5+07 - CULVERT5+03 - PED3+95 - BORE PIT3+74 - CULVERT3+48 - CULVERT3+31 -CULVERT3+13 - WOOD FENCE3+08 - COMM PED2+99 - EOP2+62 - EOP2+91 - SEWER LINE2+79 SWR SWR SWR SWR SWR SWR SWR - D/W2+06 - D/W2+35 - CULVERT2+39 - CULVERT2+50 - COMM PED2+40 DRIVEWAY DRIVEWAY 6' 2' 13'DIG 4'x4'x5'BORE PIT3' 3' 6' 6' - CULVERT1+99 - CULVERT1+38- WOOD FENCE1+70- WOOD FENCE1+34 S- SEWER MH1+35- D/W1+00- D/W1+31 6'- CULVERT0+83- CULVERT0+56- POLE0+68- FLUME0+80 SIDEWALK- BACK OF SW0+47- EOP0+10- EOP0+39 SWR SWR SWR SWR SWR SWRWTRWTRWTRWTRWTRWTRSSW- SEWER MH0+25- WATER LINE0+30- POLE0+07 RPC248OCEANWAVESDRIVEWAY HAPPYTRAILS490