Loading...
1883 Beach Ave Siding Permit Submittal r '`L"'i-,,\ Building Permit Application Updated 10/9/18 ,t' : Vj City of Atlantic Beach Building Department **ALL INFORMATION ; 4 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY n 0 IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 188 3 awl, Ave 441a,,4,t. L Foch, R. 32233 Permit Number: Legal Description /,j-O5.7 9-,23- G/4E/N. 4/4144, 6,--4ci ci,,,,.tA?A0/e45 &N7 2E# /694.85- OX1f7 Valuation of Work(Replacement Cost)$ 8o K. Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New ❑Addition Iteration ❑Repair ❑Move ❑Demo DPool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial ,lafiesidential • If an existing structure, is a fire sprinkler system installed?: DYes ,01Vo • Will tree(s) be removed in association with proposed project? ❑Yes (must submit separate Tree Removal Permit) ,.LTNo Describe in detail the type of work to be performed: Re-enc./Al o'C eX041,12 ,y'lvcc.c d'aaeer Afia insf'.t I/ 5.1411 IJA-P•rPApo .,! -r .e -:.,r eF futhias Florida Prodict Approval# for multiple products use product approval form Property Owner Information Name 3 h r-+ X;,,,,ne I Address 1883 Bead A'-e City Af/an ie,. (3eq,cl, State FL. Zip 32233 Phone 901i- 313 - 3487 E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Aurorra (3v,l o/rr; Qualifying Agent /'),'chAc1 /<. Ler,Ahen Address Po iSox 3,29 City Poatc Venlr.q State FL. Zip 3Zooy Office Phone 5'0'1 -.Z tit — 5-4/00 X -/Q7 Job Site Contact Number q/Z — /77- 37013 State Certification/Registration# CSC -1x513'9 I E-Mail j e g a Aur)C4 b ui Idle ri . Gosh N Architect Name& Phone# VA Engineer's Name& Phone# /✓/q Workers Compensation Insurer OR Exempt Expiration Date 1- /C- 2c701 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOU' .'OTIC •F,COM,., ENCEMENT. ... < _k____ A gnature o Owner or Agent) (Signature of Contractor) Signed and sworn to(or affirmed) before me this n1day of S.• ;d and sworn to,(or a irme before me thise13 day of Set ,ZO U b fU la 11(E1 ....A�'�w • a , y o6-16,�.A✓ie _- Terry Hendry �� a o2 (Signa ire of Notary) Notary Public ( '04,', FLORINDA R.CNRISMAN ._ State of Florida �_• �.': Notary Public-State of Florida '-4 My i ion Expires 11/30/2021 ( . Commission r GG 935204 P [ ] rsonally Known OR I or h My Comm.Expires Feb 9,2024 1.4;i1 9� .atioq 172 rof Id ed Idcatio c: n [ Produced Identification f Bonded through National Notary Assn. Type of Identification: fl I�U(�t5 Li Type of Identification: • • , S 3`t • • .�. NOTICE OF COMMENCEMENT State of Flor'tclA Tax Folio No. 169 685- - CO County of D u r,q To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 15 - 057 • a9 E _ /V. 44-14n f<< BeAcI ON,f a Go+ 45 EX ,/ �/z Address of property being improved: 1683 ReAcI Pave Bew t,, FL 3 ZZ 033 _ General description of improvements: 12eiv,ov41 eact3174 , 3+0 cco ve,.)ee, Ar,,J no 3+'A //,q+,o,., 0- 3rd n$ . EJrrice prbo;m y And dee it;n I of p,4+to s _ Owner: S*)Arf lk;mm r I Address: 1633 Brack lave. Mi nik. QewcJ,� R 3 2233 Owner's interest in site of the improvement: Pee 5ra pk Fee Simple Titleholder(if other than owner): Name: Contractor: qurocA 8ui)ale,,5 _ Address: PO c,y. 3.2 9 Poa Vedr#4 F 3ZGUy Telephone No.: 90y- aq G- SyOO Fax No: Surety(if any) /v/,g Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: NV,e) Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: /VA Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2) (b), Florida Statues. (Fill in at Owner's option) Name: w/,g Address: Telephone No: Fax No: Expiration date of Notice of Commencement (the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Terry Hendry Signed: Date: V/7/2-"� A(( Notary Public Before me this 11 frh day of 54)t. 2DL0 in the C9unty of Duval,State J State of Florida 'Of Florida,has personally appeared to e.eut Kl vv11Nle- �i► MyCAmmission Expires 11/30/2021 Notary Public at Large,State of Florida,County of Duval. Conunission No.G('155172 My commission expires: l l' 3a"c9-- Personally Known: or Produced Identification: Or LLY-e.A Lt G_ . •- ., •' • • • • .• , • • ••• . . 4 . • • • '•, ..• • • '; re"01 vroir ).‘) taINIBE. 't vtoi ' Construction Site Management for Exterior Renovation Project: Stuart Kimmel 1883 Beach Ave Atlantic Beach, FL 32233 1. Parking Plan—All vendors will be parking in the public spaces on (18th) street and walking to the site as the dumpster and the chemical toilet will be located in the driveway. 2. No trailers will be on site. Vendors will unload at the site and park in the public spaces at (18th) street. 3. Chemical toilet will be located in the private driveway on the right side. 4. 5 yard dumpster will be located in the private driveway in front of the garage. 5. All deliveries will need to be made to the driveway in front of the dumpster and immediately relocated to the yard. 6. Site is to remain clean 7. Erosion Control- No earth is to be disturbed,there is a 6' fence that surrounds the property. 9/14/2020 Duval Property Map PROPERTIES _ - CL 4 DUVAL MAPS _ 1 . tool IIII! .' t:i 41t... I . .,• / Ii 412 I . . I- W4* - „,_ It. ,: r 401 - - i so , ._ ECG) ,... .. ...mir # ... • , .... • '4 4 •48 4 . ire a I ' i • 1, ..,. ir °ill _j______ 'IN • *4. Ili 4 ,,.... . . . a. iit• .. -, * ...... 4.. .401 . t ..„ .0 0 1 a _Idt-Sap- IPor . 1 r _..........iii r . 24 . ,., .5, 1 I 87 -01.1 , • - - ' ,li ,. r• , . 41)/A I a it __ _ ....._ _ . NW" a iimo - ti , , 111F.e- 1 ... - ' -. ). „rat. et. *I ibillilli a 'lir - _ ... .1 4. votbe r ., 24IP' - iii 1 1 7411142 . . r • -• • i D I 1 1 ,. I '. • 4* ••• ' .1, . • ' . , ,-, 8 er NO 4 it it 4 a' a IP 1885 I 7. daZ til . ii .'' 111A itril'-fitiL • i ip - Ale i .abilitig ,v _ 4 . Vim. r ... . : — liii77-11111'111"" . • • . ... • .. - 7_ .a. ' W II ,I, Or" .0, •_ = 4 o e# °°214113:1 "Ve• o. 4 4 a i •. dt. 1 , " 44 41 it .4.. _ . ... .., . ... . , . . 1004 It- i -• N % wir ..- . NEI , r • .• maps.coi.net/duvalproperty/defaultaspx?img=img&RE=169685-0000 1/1 ft';'- ' �� PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: 1883 Lae, dt Ave c}N4,4.-c. ReArA, FL 3 Z233 Permit#: *Owner/Project Name: 3- Art Kr,,, me I As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s)for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5.Automatic 6. Other B.WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 1 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# _ C. PANEL WALL 1. Siding Cel«+ by Rata!, q„k,1 PVc. 5;d;ng f=L /7037-r23 2.Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7.Glass block 8. Membrane 9. Greenhouse 10.Synthetic stucco 11. Other D. ROOFING PRODUCTS 1.Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7.Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F.STRUCTURAL COMPONENTS 1. Wood connector/anchor 2.Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other jme.,e4 . Ply - U K �,J,rf�p S r/�.K FL /5-o27.2. G. SKYLIGHTS 1. Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. Page 3 of 4 Updated 10/17/18 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name): ���+ Q.r(,�( *Contractor Signature: deeel *Company Name: g3..JJ,..) *Mailing Address: f o Bog 329 *City: itd !/c.,[,,. *State: f . *Zip Code: 32ooy *Telephone Number: 4ale ?De/ 2yt Stioo *E-mail Address: /-o6t/ jelT Gam' .�a��,.,o /40fife Cell Phone Number: y/2 f77 Sva Fax Number: Page 4 of 4 Updated 10/17/18 9/15/2020 Florida Building Code Online M,/i Yww MONICA • OIPAFb INT or - mLV. _ usiness & Professional Regulation ,. , . 411 ,, TDBPR HOME ABOUT DBPR DBPR DIVISIONS CONTACT BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links ! Search d Florida prProduct Approval USER:Public User Product Approval Menu>Application Detail FL# FL17037-R3 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Royal Building Products Address/Phone/Email 91 royal group crescent woodbridge, NON-US 14h1x9 (662) 705-0610 stan.hathorn@axiall.com Authorized Signature Stan Hathorn Stan.Hathorn@royalbuildingproducts.com Technical Representative Stan Hathorn Address/Phone/Email 312 Sloss Circle Trussville,AL 35173 (662) 705-0610 stan.hathorn@axiall.com Quality Assurance Representative Stan Hathorn Address/Phone/Email 312 Sloss Circle Trussville,AL 35173 (662) 705-0610 stan.hathorn@axiall.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity IAPMO Uniform Evaluation Services LLC. Quality Assurance Entity Architectural Testing,Inc.,an Intertek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Steven M. Urich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL17037 R3 COI CERTIFICATE OF INDEPENDENCE IAPMO ES 2014.pf Referenced Standard and Year(of Standard) Standard Year D3679 2011 Equivalence of Product Standards Certified By Sections from the Code haps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpOQe8yj09bhfsig7B3xyQGhq6SZpEuHPboleQ%3d%3d 1/2 9/15/2020 Florida Building Code Online Product Approval Method Method 1 Option C Date Submitted 01/26/2018 Date Validated 01/26/2018 Date Pending FBC Approval Date Approved 01/30/2018 Summary of Products FL# Model,Number or Name Description 17037.1 Celect Cellular Siding 7" Reveal Limits of Use Installation Instructions Approved for use in HVHZ: No FL17037 R3 II Celect Cellular V2 Guide 614.Q.df Approved for use outside HVHZ:Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-110.6 Evaluation Reports Other:Allowable negative design pressure listed.Allowable FL17037 R3 AE E1595 R0368 Royal Buildirlg,Rdf positive design pressures are dependent on the capacity of the solid sheathing substrate to withstand the positive wind forces. 17037.2 Celect Cellular Siding 4" Reveal Limits of Use Installation Instructions Approved for use in HVHZ: No FL17037 R3 II Celect Cellular V2 Guide 614.raf Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-196.5 Evaluation Reports Other:Allowable negative design pressure listed.Allowable FL17037 R3 AE E1595 R0368 Royal Building,Rdf positive design pressures are dependent on the capacity of the solid sheathing substrate to withstand the positive wind forces. 17037.3 Celect Cellular Siding 8" Board and Batten Limits of Use Installation Instructions Approved for use in HVHZ: No FL17037 R3 II Celect Cellular V2 Guide 614.ps f Approved for use outside HVHZ: Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-96.2 Evaluation Reports Other:Allowable negative design pressure listed.Allowable FL17037 R3 AE E1595 R0368 Royal Building,Rdf positive design pressures are dependent on the capacity of the solid sheathing substrate to withstand the positive wind forces. 17037.4 Celect Cellular Siding 7" Perfection Shingle Limits of Use Installation Instructions Approved for use in HVHZ: No FL17037 R3 II Celect Cellular V2 Guide 614.p.a Approved for use outside HVHZ:Yes Verified By: IAPMO Uniform Evaluation Services LLC. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +0/-123.9 Evaluation Reports Other:Allowable negative design pressure listed. Allowable FL17037 R3 AE E1595 R0368 Royal Buildingmlf positive design pressures are dependent on the capacity of the solid sheathing substrate to withstand the positive wind forces. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 phone;850-487-1824 The State of Florida is an AA/EEO employer.Cgpy.nght 2007-2013 State of Florida. ::privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®® ® aC*ck111 Credit Card Safe securitvell_TRIcs https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe8yj09bhfsig7B3xyQGhq6SZpEuHPboleQ%3d%3d 2/2 ' 13 C E L E C T HORIZONTAL SIDING & TRIM INSTALLATION GUIDE Using Padded Out V2 PVC Trim CELLULAR EXTERIORS BY ROYAL Storage Fasteners If bundles are to be stored outside,do not lay them directly on the ground.Lay • Siding them on wood supports(e.g.2X4) • Corrosion-resistant nails(stainless steel nails or galvanized roofing Do not store under tarps. nails)with a minimum head diameter of/a",'/e'shank and length Do not store bundles upright. enough to penetrate framing or furring'/,". Do not store bundles more than 5 high. • Corrosion resistant,#8 truss or pan head screws with a length Keep away from heat sources. sufficient to penetrate a solid nailable surface(framing or furring)a Wall Preparation minimum of 1-1/4"in depth. Celect siding is a rain screen but not intended to be a water resistive barrier. Trim Therefore,Celect siding must be installed over a continuous water-resistive • Celect Cortex screws and plugs are recommended to secure finished barrier with properly integrated flashing. Celect Trim pieces. New Construction • If other trim fasteners are used,they must be fasteners intended for Celect must be applied over rigid nailable sheathing that provides a smooth flat exterior use with PVC trim such as stainless steel or hot dipped surface. Never install Celect siding directly to open framing/studs. galvanize. Re-siding • DO NOT USE staples,small brads,ring shank or wire nails. It may not be necessary to remove existing siding providing all loose boards • For"padding out"finished trim,fasteners should be long enough to are re-secured and any rotten boards are replaced. Install furring strips or wall penetrate the solid wood substrate a minimum of 1 '/2'. leveling siding underlayment to create a flat surface for the siding. • Professional grade PVC adhesive for joining trim pieces. PVC adhesive along with Cyanoacrylate(super glue)and activator as a Cutting "clamp"can be used. Siding Circular or miter saws with a trim or plywood blade. Jig saw,rotary tools(Dremel,router,etc.)can be useful for cutting around obstructions. Trim The use of a compound miter saw with a trim blade is recommended. Key Vocabulary • Course-Row of siding panels,one panel wide,running the length of the wall. • Center Pin-placing a nail at both ends of a nailing slot to force the movement of the panel left and right of that slot. • Pocket-Space created behind the trim to hide or cover the panel ends so as to allow the expansion and contraction of the panel(s)without it being visible. Key Rules • Nail in the center of the nailing slot unless pinning is necessary. • Fasteners must be placed in the center of the nailing slots at approximately 16"spacing leaving about'/32"between the head of the fastener and the nailing hem of the panel.Celect panels expand and contract through temperature changes. • Never face nail the panels. Celect Installation • After preparing the walls for the siding Installation Sequence / Flash g installation(see Wall h Preparation pg. 1), install 1X2 furring 0 Weather Barrier&Flashings - d 21/2"Siding around all windows,doors,outside corners,etc.This must be done 0 Furring strips for trim �� Leve ination M� anywhere the ends of the siding will be �urring Strips—� jX / terminated(Fig 1-2). 0 Inside Corner Posts �//l _ - -,� • Make sure to install the proper flashing Lt.) Window Heade as required by specific local building Q Starter Strip for Panels i I L • ~- codes(Fig 2) I , NOTE:if the furring strips will be completely 0 Celect Siding Panels hidden by the trim, I 1X2 Furring Strip r treated 1X2 furring can be used in place of 0 Window,Door,Etc.Trim I r PVC strips. \ Fig.1 ;, \ , Fig.2 / Secure the furring every 8"- 12". • Install starter strip along the bottom of the wall fastening every 8"-12" ; ` um�9 Strips > Install insiie corners P (Fig.3). In certain situations,it may be necessary to remove a bottom section from of the panels to accommodate variations in the first course ✓ \ ' such as porch floors,etc. In these situations,where the bottom lock is 4" removed,the cut edge of the panel(s)must be covered by trim. Due to the limited expansion and contraction of the panels vertically,the face of r the channel or trim only need be wide enough to cover the cut edge of the panel by 1/2"(Fig 4). 1"gap on courses longer f Min.'/i'gap 1 • than 12',1/2"gap on N, • Install any inside corners.Fasten the inside corners using weather courses shorter than 12' resistant screws placed inside the pocket of the corner no more than 16" w Fig.3 apart(Fig 5). Unlike the other finished trim,inside corners are applied Fig 5 before th siding. NOTE:Make sure not to draw the pocket in when fastening to the wall. The pocket width must remain 3/4". Use a scrap piece of siding as a -� spacer in the pocket.The inside of the corner post should not lay against Min.'/z'co Fig.4 the siding. \ J 91 Royal Group Crescent,Woodbridge,Ontario,Canada L4H 1X9 11.800.387.2789 I royalbuildingproducts.com .A'ROYA L Building Products �: C E L E C T HORIZONTAL SIDING & TRIM QUICK GUIDE (CONT.) CELLULAR EXTERIORS BY ROYAL • Install the Celect siding panels keeping the ends of the __ 7 panels 1"away from the furring strips if the course is over f = —,,,— _.■ 12'long, 1/2"away if the course is less than 12'long. • Fasten the panels by placing a fastener in the center of the 1/2"gap If course is shorter than 12' L' n IIIIII slot approximately every 16"leaving about 1/32"between the and no center oln of course necessary. head of the fastener and the nailing hem of the panel. n Celect panels expand and contract through temperature '1,--.... changes. (Fig.6). `_ • '3 c----__ , ,--.--. a e.. e---, • If the course is longer than 12'pin the center of the course LL ( . (not each panel)by placing a fastener in each side of one �� slot keeping in mind that the"center"of each course will .4— gap if course is longer than 12' change as you work around windows,doors,etc.(Fig.7). and center pin the course. Center pin or box nail Icenter of each course • Celect siding panels can be installed continuously up to Fig.6 over 12' Fig.7 60'.If the siding courses are longer than 60',break the J NOT each panel J course(s)with an expansion joint.This joint can be fabricated using furring strip and 1'X6"(Fig.8). o — ---r---_-__ --- less than 30'�P 4--more than 30.--t• Longer than 60' 4�expansio {center pin cou��e.'/'; PIN PANELS .� THIS END--- �,��„ 1"gap 1X2 Furring Strip \ 1/2"off of i 1 ` 1/2"off roof line - •rooftine i r with no channel. --sem�' ~ii L Less than 30' More than 30' Expansion Joint \` Fig 9 I r Fig.1_0} Fig.8 • Fixture mounts can be field constructed using Cellular PVC,wood,etc.The pocket depth must be 2"for courses over 12'and 3/4"for courses under 12'to allow for the appropriate expansion gap. • For courses under 12'preformed vinyl siding fixture mounts can be used. In this case, o the expansion gap should be 3/8"(Fig 11). Fixture Block Fig.11 /K._ `\ • Depending upon the trim you choose to you use to finish the top of the wall, measure and cut the top course panel to fit. Due to the limited expansion and contraction of the panels vertically,the face of the channel or trim only need be wide enough to cover the cut edge of the panel by W. • Install the panel securing it by placing nails along the cut edge of the panel approximately every 16".DO NOT FACE NAIL THE PANEL.The head of the nails will hold the panel r� back to the wall and the shaft of the nail will keep the panel from raising and becoming Cut top of siding unlocked from the panel below it(Fig 12). Fig. 12 J • Install trim over furring strips(Fig. 13-14). It is easiest to assemble I" ' window and door trims before applying them to the wall.When using ��� Celect trim,be sure to build the trim slightly larger(ur"each side)than the window or door to give the finished frame room to expand and contract „_'i through temperature changes. �'�>�• Cortex screws and matching plugs should be used when installing Celect V �trim.Space the fasteners no more than 16"apart and no closer than 2" • i....,:::,..::: % \\\ \j \from the end of the trim. Make sure not to fasten through the siding or into ; the expansion pocket(Fig 14). 1\ d'f \\ 1 • Fig.13 v/- )./( / Fig 14� 91 Royal Group Crescent,Woodbridge,Ontario,Canada L4H 1X9 11.800.387.2789 I royalbuildingproducts.com %AO ROYAL Building Products 2 EVALUATION REPORT Number 368 TM Originally Issued: 2/01/2015 Revised: 11/15/2017 Valid Through: 2/29/2018 ROYAL BUILDING PRODUCTS capacity of the solid sheathing substrate to withstand the positive wind forces. CELECT CELLULAR SIDING 3.2 Installation: Installation of Royal Building Products' CSI Section: 07 46 33 Plastic Siding Celect Cellular Siding shall be in accordance with the manufacturer's published installation instructions, the 1.0 RECOGNITION applicable code and this report. The siding panels shall be installed in accordance with the installation instructions to Royal Building Products Celect Cellular Siding products allow movement of the siding panels due to temperature described in this report were evaluated for use as exterior changes. The panels shall be fastened at the maximum on- covering materials for walls as part of the weather-resistant center spacing given in Table 1,to minimum 0.42-specific- exterior wall envelope. The exterior veneer,wind resistance, gravity wood substrate. The fasteners shall be corrosion- and installation properties of the Celect Cellular Siding resistant roofing nails having minimum 1/8-inch-diameter products were evaluated.The siding products are satisfactory shanks,3/8-inch-diameter heads, and shall be minimum 11/2 alternatives to those prescribed in the following codes: inches long,or equivalent;or corrosion-resistant No.8 truss- head screws minimum 11/4 inches long, or equivalent, as • 2015, 2012, 2009, and 2006 International Building described in Table 1. Code®(IBC) • 2015, 2012, 2009, and 2006 International 4.0 PRODUCT DESCRIPTION Residential Code®(IRC) • 2017 and 2014 Florida Building Code, Building, Royal Building Products Celect Cellular Siding is an and Florida Building Code, Residential — See alternative siding to those prescribed in IBC Section 1404.9 attached Supplement and IRC Section R703.11.Celect Cellular Siding is made of polyvinyl chloride(PVC)with an expanded core. Celect Cellular Siding is for use in Type V Construction and buildings constructed in accordance with the IRC. Celect Royal Building Products Celect Cellular Siding is available Cellular Siding may also be used in Construction Types I - in 4-inch and 7-inch horizontal clapboard profiles, 7-inch IV in accordance with Section 1406.2 of the IBC. Perfection Shingle shake profile, and 8-inch Board and Batten vertical profile siding. The 7-inch clapboard and 7- 2.0 LIMITATIONS inch shake profiles are similar except for the shake texture. The 4-inch clapboard siding is packaged in 12 foot-6 inch Use of the Royal Building Products Celect Cellular Siding (3.81 m) lengths. The 7-inch clapboard siding is packaged recognized in this report is subject to the following in 12 foot-4 inch (3.76 m) lengths. The Perfection Shingle limitations: is packaged in panels 48 inches(1.22 m)long.The Board& Batten is packaged in 10-foot(3.05 m)lengths. 2.1 The Siding shall be installed in accordance with the applicable code, the manufacturer's published installation 5.0 IDENTIFICATION instructions, and this report. Where there is a conflict, the most restrictive shall govern. A label shall be affixed on the packaging and shall include the Royal Building Products name or trademark, the 2.2 Royal Building Products Celect Cellular Siding shall be manufacturer's address, the product model number, the installed over solid sheathing capable of resisting the design IAPMO Uniform ES Mark of Conformity,and the Evaluation wind pressures. Report Number (ER-368). Either Mark of Conformity may be used as shown below: 2.3 Flashing and water-resistive barrier shall be installed as required by the applicable code. 3.0 PRODUCT USE 3.1 Design: Design wind pressures shall be determined in IAtr\li accordance with Section 1609 of the IBC or R301.2.1 of the IRC, as applicable, and shall not exceed the allowable pressures tabulated in this report for use of Celect Cellular Siding. The allowable negative wind pressures for Royal Or TM Building Products Celect Cellular Siding are shown in Table IAPMO UES ER-368 1. Allowable positive pressures are dependent on the UAW The product described in this Uniform Evaluation Service(UES)Report has been evaluated as an alternative material,design or method of construction in order to satisfy and comply with CNE/ the intent of the provision of the code,as noted in this report,and for at least equivalence to that prescribed in the code in quality,strength,effectiveness,fire resistance,durability and safely, as applicable,in accordance with IBC Section 104.11.This document shall only be reproduced in its entirety. /��/c Copyright®2017 by International Association of Plumbing and Mechanical Officials.All rights reserved.Printed in the United States. Ph:1-877-4IESRPT•Fax:909.472.4171 Nft�7I web:www.unifomes.org•4755 East Philadelphia Street,Ontario,California 91761-2816—USA %II* EVALUATION REPORT Number 368 TM Originally Issued: 2/01/2015 Revised: 11/15/2017 Valid Through: 2/29/2018 6.0 SUBSTANTIATING DATA 7.0 CONTACT INFORMATION 6.1 Reports of testing in accordance with ASTM D3679 as Royal Building Products required by ICC-ES Acceptance Criteria for Vinyl Siding 328 Industrial Drive (AC37),dated February 2014. Bristol,Tennessee 37620 (276)783-8161 6.2 Data in accordance with ICC-ES Acceptance Criteria for Website:www.royalbuildingproducts.com Rigid Cellular PVC Non-load-bearing Exterior Trim (AC227), dated December 2004 (editorially revised June 8.0 STATEMENT OF RECOGNITION 2012)as follows: o Reports of deflection temperature testing in This evaluation report describes the results of research accordance with ASTM D648. carried out by IAPMO Uniform Evaluation Service on o Reports of density properties testing in accordance Royal Building Products Celect Cellular Siding with ASTM D792. manufactured in Bristol, Tennessee to assess its o Reports of flexural properties testing in accordance conformance to the codes shown in Section 1.0 of this with ASTM D790. report, and serves as documentation of the product certification. 6.3 Reports of ASTM D7254 impact resistance testing in accordance with ICC-ES Acceptance Criteria for '? , Polypropylene Siding(AC366),dated April 2007(editorially )/,•p �,1,,fw revised April 2011). Brian Gerber,P.E.,S.E. 6.4 Reports of wind resistance testing in accordance with Vice President,Technical Operations ASTM D5206. Uniform Evaluation Service 6.5 Reports of testing in accordance with Section 3.3 of ICC- ES AC37, dated February 2014 to determine an alternative pressure equalization factor for this siding product. Richard Beck,PE,CBO,MCP Vice President,Uniform Evaluation Service 6.6 Reports of ignitability testing in accordance with NFPA 268. 6.7 Quality control documentation. GP Russ Chane CEO,The IAPMO Group For additional information about this evaluation report please visit www.uniform-es.org or email at info(a)uniform-es.org Page 2 of 4 1144 EVALUATION REPORT Number 368 TM Originally Issued: 2/01/2015 Revised: 11/15/2017 Valid Through: 2/29/2018 T:U13LE 1— MAXIMUM ALLOWABLE NEGATIVE WIND PRESSURES FOR CELECT CELLULAR SIDING Exposure Allowable Negative p 2 Spacing Attachment Siding Profile Fastener Type a Wind Pressures (in.) (in.) Substrate (Ps01 ea 1.25"No.8 truss head screws 16 Into Son,ything 136.8 16 Into Sheathing 72.1 Horizontal 7-inch only Clapboard 7 1.5"smooth-shank roofing 8 Into Sheathing 96.2 nails only 16 Through Sheathing 110.6 into Framing Horizontal 4-inch I.5"smooth-shank roofing Through Sheathing Clapboard 4 nails 16 into Framing 196.5 Horizontal 7-inch 1.5"smooth-shank roofing Through Sheathing Shake 7 nails 16 into Framing 123.9 Vertical 8-inch 1.5"smooth-shank roofing Into Sheathing Board&Batten 8 nails 12 only 96.2 For SI: 1 inch=25.4 mm,1 psf=47.9 N/m2 1. Indicates maximum allowable wind pressures for the siding fastened using the fastener types and on-center spacing indicated in the columns above. 2. The roofing nails shall have minimum 3/g-inch-diameter heads,Vg-inch-diameter shanks,and 1'/4-inch embedment into the substrate. 3. The attachment substrate shall have specific gravity of 0.42 minimum. I 5.411 in. 1 T-? ._... 0.629 in. ----I~ I r/ 0.358in.-1 Horizontal 4-inch Clapboard 8.470 in. II__________, 0.678 in. J 1 S1 0.358 in. Horizontal 7-inch Clapboard&Horizontal 7-inch Shake 9.153 in. I 1 i 0.749 in. -- 1 0.327 in.-1 Vertical 8-inch Board&Batten FIGURE 1—SIDING PROFILES Page 3 of 4 kitt EVALUATION REPORT Numbe 368 rM Originally Issued: 2/01/2015 Revised: 11/15/2017 Valid Through: 2/29/2018 Florida Supplement ROYAL BUILDING PRODUCTS Use of the Royal Building Products Celect Cellular Siding Profiles for compliance with the high-velocity hurricane zone CELECT CELLULAR SIDING (HVHZ) provisions of the FBC, Building and FBC, Residential has not been evaluated and is outside the scope of CSI Section: 07 46 33 Plastic Siding this evaluation report. 1.0 RECOGNITION For products falling under Florida Rule 61G20-3,verification is required that the report holder's quality assurance program Royal Building Products Celect Cellular Siding Profiles is audited by a quality assurance entity, approved by the described in IAPMO UES Evaluation Report ER-368 are Florida Building Commission(or the building official when satisfactory alternatives to the cladding systems prescribed in the report holder does not possess an approval by the the following codes: Commission), to provide oversight and determine that the products are being manufactured as described in this • 2017 and 2014 Florida Building Code, Building evaluation report to establish continual product performance. (FBC,Building) • 2017 and 2014 Florida Building Code, Residential 3.0 CONTACT INFORMATION (FBC,Residential) Royal Building Products 2.0 LIMITATIONS 328 Industrial Drive Bristol,Tennessee 37620 Installation shall be in accordance with ER-368, the (276)783-8161 manufacturer's published installation instructions, and Website: www.royalbuildingproducts.com Section 1405 of the FBC, Building or Section R703 of the FBC, Residential, as applicable. Flashing shall comply with Section 1405.4 of the FBC,Building. For additional information about this evaluation report please visit www.uniform-es.org or email at info(a;uniform-es.org For buildings built in accordance with the FBC, Residential, design wind loads for cladding shall be determined in accordance with Tables R301.2(2)and R301.2(3),as required by Section R301.2.1 of the FBC,Residential;when required, conversion between Vw,(Ultimate Design Wind Speed) and V (Nominal Design Wind Speed) shall be in accordance with R301.2.1.3 of the FBC, Residential. For buildings built in accordance with the FBC,Building,design wind loads for cladding shall be determined in accordance with Section 1609.1.1 of the FBC, Building; when required, conversion between V, and Vasd shall be in accordance with 1609.3.1 of the FBC,Building.Allowable design pressures determined in accordance with the FBC shall not exceed those in Table 1 of ER-368. Page 4 of 4