Loading...
94 Oceanside Dr RES20-0261 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: BRADLEY HELEN G 94 OCEANSIDE DR ATLANTIC BEACH FL 32233-5927 COMPANY:ADDRESS:CITY:STATE:ZIP: Renewal by Andersen of Florida 997 W Kennedy Blvd Orlando Fl 32810 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 168846 5160 OCEAN SIDE JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 94 OCEANSIDE DR RESIDENTIAL WINDOWS/DOORS ONE DOOR $5749.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $124.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 9/25/2020 PERMIT NUMBER RES20-0261 ISSUED: 9/25/2020 EXPIRES: 3/24/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 9/25/2020 PERMIT NUMBER RES20-0261 ISSUED: 9/25/2020 EXPIRES: 3/24/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 RES20-0261 Building Permit Application City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (904) 247-5845 Job Address: 94 Oceanside Drive, Atlantic Beach, FL 32233 Permit Number: Updated 12/8/17 ------------ Legal Description 44-34 37-2S-29E OCEAN SIDE LOT 12 Valuation of Work (Replacement Cost) $ ,S: 7 Lf q Heated/Cooled SF Non-Heated/Cooled ----------- • • Class of Work (Circle one): New Addition Alteration Repair Move Demo Use of existing/proposed structure(s) (Circle one): Commercial ~ Pool ~r • If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Repl ae1'n_1 I c.lcnr 51-uL ~r siv0 Florida Product Approval # _ _,/_t..{-+-L/..,__=lS_ff---'---'.'""S..__ ____________ for multiple products use product approval form Property Owner Information Name: Bradley, Helen C Address: 94 Oceanside Drive City Atlantic Beach E-Mail __________________________________________ _ State FL Zip 32233 Phone 9oY-,;,..y, -337 7 Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) ___________________ _ Contractor Information Name of Company: Renewal by Andersen of Florida Address 997 W Kennedy Blvd Office Phone 407-803-4723 State Certification/Registration # CGC 1527613 Architect Name & Phone # Qualifying Agent: Jared Mellick ----------------City Orlando State FL Zip 32810 --- Job Site/Contact Number _______________ _ E-Mail Permitting@rbafla.com ------------------------------------ Engineer's Name & Phone#------------------------------------ Workers Compensation-------------,-----------,------------------ Exempt I Insurer/ Lease Employees/ Expirati on Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may b e additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. t) (including contr Signed and sworn to (or affi · )l.. day of ~L« b ' ;)..();) ~~~~~=------ ( ] Personally Known OR fM Produced ldentificati~ _ f ype of Identificat ion: .f1...P Sign and sworn to (or affirmed) before me this ~ day of ~ .<w=>o . by ..:11tfd M./LU (JA. ~~ (Signature of Notary) RES20-0261 Doc# 2020184776, OR BK 19341 Page 1033, Number Pages: 1, Recorded 08/24/2020 02:36 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 NOTICE OF COMMENCEMENT lf'l'EPAAE IN OUPUCATE) Tax Folio No. 168846-5160 Countyof __ Dwai ___________ _ PermltNo._.,... ________ _ s~.~-~---------- To whom It lnllY WOC9m: The unCMrslgMd hereby Informs you that lmprowm.nts will .,. mac» to c.natn ruJ p,opwty, and In •cc:ordan~ with ~on 713 of the Fl~ 8tatutes, the following lnfomlatlon 15 stated In ttlls NOTICE Of' COMNENC:eMENT. Legal de$~ or~ bei1g 1,nprovec1: 44-34 37-2S-29E OCEAN SIDE LOT 12 Acttess or property~ Improved: 94 OCEANSIDE DRIVE, Atlantk Beach, FL 32233 General c1esa1p11or1 of Improvements: Replacing windows/doors size for size owner BRADLEY, HELEN G MdtMs 94 OCEANSIDE DRIVE. Atlantic Beach, FL 32233 OWner'slnterest In site of the ~ovemenc_owne __ r ________________ _ Fee 8i11Jie Titleholder (if olheTtianowner) __________________ _ Name ____________________________ _ Address ___________________________ _ Contractor ReMwal by Andersen of Florida /Jared Melick Addres, 997 w kennedy etlld. Ortaodo, R. 32810 Phone No. 407~723 Fax No. ____________ _ Svrety(lfany) __________________________ _ Address _______________ __,Amountof bond$..,.. _____ _ Phor-.. No. ___________ Fax No. ____________ _ Name Ind 1ddress of any Pfll'IOfl meksio a loan for tie c;onstrucllon of the imp(ovements. Namo ____________________________ _ Address ___________________________ _ Phone No. ___________ Fex No. ____________ _ Name of person wtttm !!le Stec. or Aortde, other t!'len llimser. designated by O',o1llf upcn wtlom notices or other doa.iments may be served: Name ____________________________ _ Addreu ___________________________ _ Phooe No. ___________ FuNo .. ____________ _ In addition ,o hlmself, ~ dfflgnatH the fo/lowilg person to receive • copy ot the Uenor's Notice 11S providecl In Section 713.06 (21 (b}, Florida StaMes. (Fll In et CMner's optlon). Name ____________________________ _ Address ___________________________ _ PhoneNo. __________ FaxNo. _____________ _ Expiration o,te of Notice of Commenc:emeot (11\e expiration d•~ Is OM (1) year from the elate or ,-cording unlass a different date ilspldfitd): _______________________ _ THIS IPAC! l'Oft ft OPU>!ft'S USI! ONLY I ;151 1!11 ~-"'_f::) __ ,_, _._eouvy __ «_P_u_w_,_Of__. °' Renewal byAndersen. WINDOW REPLACEMENT Order Summary dba: RENEWAL BY ANDERSEN OF FLORJDA Legal Name: JLM Windows, LLC I License# CGC1527613 997 West Kennedy Blvd. Ste A-18 I Orlando, FL 32810 Phone: 407-803-4723 I Fax : 407-386-8262 I concierge@rbafla.com Measure Tech : Johnny Lee, HELEN BRADLEY 94 Oceanside Dr ive Atlantic Beach. FL 32233 H: (904)247-3377 IC : ID# ROOM SIZE DETAILS JOB 101 Office 70-3/4" 70-3/4" 78-3/4" 78-3/4" Patio Door: Gliding, 200 Series Per ma-Shield, 2 Panel, Stationary/ Act i ve, Exterior White, Interior White Glass: Al l Sash : Tempered High Perf . SmartSun Glass Hardware: Albany, White, Auxil iary Foot Lock Color Matched Screen: No Screen Grille Style: No Grille Misc: None Construction: None Material: Caulk -White Exterior (1), 2.25" x 5/8" L-Trim , (12 ft), White (3) PRODUCTS: 1 WINDOWS: 0 PATIO DOORS: 1 SPECIALTY: 0 MISC: 0 Updated 8113120 JOB NOTES Estimated Duration: FLOORPLAN -1ST FLOOR UNIT NOTES FRONT JOB PHOTOS 08/1 3/20 Pa g e2 /6 RES20-0261 Doc# 2020184776, OR BK 19341 Page 1033, Number Pages: 1 , Recorded 08/24/2020 02:36 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 NOTICE OF COMMENCEMENT lf"f'EPAAE IN OUPUCAff'.) Tax Folto No. 168846-S l 60 Countyof __ bwi ____________ _ PermltNo . .....,. _________ _ Stated_flalldl __________ _ To whom H lllll)' concern: The undersign.cl hereby Informs you that lmprov.ments will i,. mam to certain rul property, and In •ccordance with Se¢tlon 713 of the Florida. Statutes, lhe following Information Is stat~ In thf5 NOTICE Of COMIIENCl!MENT. Leoaldesetllllonofp,operty being Improved: 44-34 37-2S-29E OCEAN SIDE LOT 12 Address of property being Improved: 94 OCEANSIDE DRIVE, Atlantic Beach, FL 32233 General description of lmp«>Vements: Replacing windows/doors size for size OWner BRADLEY, HELEN G Addtess 94 OCEANSIDE DRIVE, Atlantic Beach, FL 32233 OWner's Interest In site of the 1rr1>rovemen1_aw_ne_r _________________ _ Fee~ Tillehofder(lf olherflan owner) ___________________ _ Namo ______________________________ _ Address ____________________________ _ contractor ReMwal by Andersen of Florida /.Jalfd Mellick Address 997 W Kennedy Blvd. Orlando, R. 32810 Phone No. 407.aoum Fax No. _____________ _ SVrety(lfany) ___________________________ _ Addtes$ __________________ Amountof bond$ ______ _ PhoneNo. ____________ FaxNo. _____________ _ Name and address of any pel'SQII maklnD a loan for lhe c;onslJUcllon of 1he impfovements. Namo ______________________________ _ A~ress ____________________________ _ !'hone No. ____________ Fax No. _____________ _ Name of person withil tile s1-i. d Aortde. other tnan n1ms.r. deslgnai.11 by O',\IMf UPon Wh0m notices or OCher doannantsmay ba served: Name ______________________________ _ Address ____________________________ _ Pf'loM No. ____________ Fax No .. _____________ _ In addition to tllmself, o-designates the fOllowr,g pal'lon 1D receive• copy oftha Uenor·s Notice es provided ln section 713.06 (21 (b), Florida statutes. <A• In et~, O!)tion). N11m1t _____________________________ _ Address ____________________________ _ PhoneNo. ___________ FaxNo. ______________ _ Explratton cs,te of Notice ot Commencement (the expltatlon datA! ls one (1) year from the date or ~ng unless • dift'arentdatets~): ________________________ _ THIS IPAC! l'Oft ft ORDll''S UH ONI. Y Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2017.10.20 20:52:38 -04'00' ANDERSEN CORPORATION INSTALLATION NOTES: 200 SERIES PERMA-SHIELD GLIDING PA TIO DOOR NON-IMPACT 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN, UNLESS OTHERWISE STATED. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF ±1/2 INCH OF THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. THROUGH FRAME: FOR INSTALLATION INTO 2X BUCK OR FRAMING USE #10 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 11/2 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE AND MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 5. THROUGH FRAME: FOR INSTALLATION THROUGH lX BUCK TO CONCRETE/MASONRY, OR DIRECTLY INTO CONCRETE/MASONRY, USE ½6" ITW TAPCONS OF SUFFICIENT LENGTH TO ACHIEVE 11/4 INCH MINIMUM EMBEDMENT AND MAINTAIN MINIMUM 2" EDGE DISTANCE. 10. THROUGH FRAME: FOR INSTALLATION INTO METAL SUBSTRATES USE #10 GRADE 5 SELF-DRILLING OR SELF-TAPPING SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL FRAME SUBSTRATE AND MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 11. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 12. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 13. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 14. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 15. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD -MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. C. MASONRY -STRENGTH CONFORMANCE TO ASTM C-90. MIN BLOCK COMPRESSIVE STRENGTH 2000 PSI. D. STEEL -MINIMUM YIELD STRENGTH OF 33 KSI. MINIMUM WALL THICKNESS OF 33 MILS (20 GAUGE). E. ALUMINUM -MINIMUM 6063-TS ALLOY. MINIMUM WALL THICKNESS OF 1/8". GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC), EXCWDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • AAMA/WDMA/CSA 101/I.S.2/A440-08/11 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X AND METAL STUD FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. lX AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED TO PROTECT THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. DOOR MATERIAL: WOOD AND VINYL 7. GLASS MEETS THE REQUIREMENTS OF ASTM E1300 GLASS CHARTS. SEE SHEET 8 FOR GLAZING DETAILS. 8. DESIGNATIONS "X" AND "O" STAND FOR THE FOLLOWING: X: ACTIVE PANEL 0: STATIONARY PANEL 9. CUSTOM SIZES AVAILABLE UPON REQUEST. CUSTOM DESIGN PRESSURE WILL BE ASSIGNED EQUAL TO NEXT LARGER STANDARD SIZE. SHEET 1 2 3 4 5 6 PRODUCT PSGPD4380S IG PSGPD8180AS IG PSGPD81611AS DPUP IG TABLE OF CONTENTS REVISION SHEET DESCRIPTION -GENERAL AND INSTALLATION NOTES -ELEVATIONS & ANCHOR LAYOUTS -VERTICAL SECTIONS -VERTICAL SECTIONS & GLAZING DETAILS -HORIZONTAL SECTIONS -SIDELITE MULLIONS DESIGN PRESSURE RATING O.A. SIZE CONFIGURATION DESIGN PRESSURE 501/s"X95½" 0 +45.0 / -45.0 PSF 96" X95½" XO +25.0 / -25.0 PSF 96"X82¾" XO +40.0 / -40.0 PSF MISSILE IMPACT RATING NON-IMPACT Andersen Wit.I DOWS • DOORS 100 FOURTH AVE NORTH BAYPORT, MN 55003-1096 PH: j651) 264-5150 FX: (651) 264-5485 V'l u:11 0 w ~": E i:i'.l a:: 0 ~ ~ ~ 8 z :i: g z ~ ~::i~ i!! l 0 o'"'_.j.i:i, ~o ~ O:"'"-:Jc ~o Cl i5::c!!2.~;ii -' ~~~ii~ a:: j::: ~ z:!!:!!;:~i ~~ -~z a....._ ~ 0 c~ m !nl!> ::::! "' ~ C :::, !li -~ z a:: -<C ~a:i LI.IS -' V) .... < C ~ g l!> a: w w -~ z a:: w f w ID -I w I-a:: j::: 0.. REMARKS BY DATE IS DOCUMENT IS TliE PROPEJITT' OF BUILDIN!i DROPS, I AND SHAU. NOT BE REPRODUCED IN WHOLE 011 PART WITHOUT WRITTEN CONSENT OF BUIUJING DROPS, INC. AL TERATlONS, ADDITIONS, HIGHLIGHTING. OR CJTliER MARKINGS TO THIS DOaJMENT ARE NOT PERMITTED AND INVALIDATE OUR CElmFICATIDN. FL#: FL14429 DATE: lQ.16.17 DWG.BY: CHK. BY: SM HFN SCALE: NTS DWG.#: AWD191 SHEET: 4] OF 7 UNIT MAX. WIDTH 96.00" PANEL MAX. ----~...,,_ D.L.O. MAX. WIDTH 48.375" WIDTH 43.125" UNIT PANEL MAX. MAX. HEIGHT HEIGHT 95.50" 92.25" D.L.O MAX. HEIGHT 86.875" 10" MAX. FROM CORNERS --1-•-•-1 10"MAX. F / FROM CORNERS t 12.5" MAX. O.C. l X 0 I ELEVATION ~, •---1•-l-1-19" MAX. O.C. I X 0 ANCHOR LAYOUT THROUGH FRAME INSTALLATION UNIT MAX. HEIGHT 95.50" PANEL MAX. HEIGHT 92.25" D.L.O MAX. HEIGHT 86.875" UNIT MAX. WIDTH 50.375" PANEL MAX. WIDTH 48.375" D.L.O. MAX. WIDTH 43.125" I 0 ~ ELEVATION 10" MAX. FROM----i---1 CORNERS I : 10" MAX. -FROM CORNERS t 19" MAX.O.C. l SET ENTIRE SILL IN BED OF STRUCTURAL SILICONE SEALANT, (MIN THREE½" BEADS) - - - - I I I 0 ' /f ANCHOR LAVOU THROUGH FRAME INSTALLATION - - - T W I NDOWS• D O ORS 100 FOURTH AVE NORTH BAYPORT, MN 55003-1096 PH: (651) 264·5150 FX: (6511264•5485 Q ~ u:ii ::, ~ ~ E i:i:l0::: 0 'I;;§ 8 -o ; ~, m~a_ ~o C t'r1...,. 0 0 ~ '.'.: i""i. 'Q a:: cc: ... _ ::i= ~o 0 oo~ ... i::-.:2 :I: ~;~iJ.~ ~~ u z z:!!:!!;;~d < c~~A.~ oll Cc ,i:i ~\.!) II) ....I ... i -:c:: z 5 g: 0:::-0 >cc"' ~§ ~ al 8 \.!) 0 ~ UJ w ...J tr. -~ UJ c( UJ Q,,, ...J w I-tr. i== Q,,, REMARKS BY DATE AND SHAU NOT BE REPRODUCED IN WHOLE OR PART WITHOUT WRITTEN CONSENT OF BUIIDING DROPS, INC. ALTERATIONS, ADDITIONS. HIGHLIGHTING, OR antER MARKINGS TO THIS DOCUMENT ARE NOT PERMIITTDAND INVALIDATE OUR CERTIFICATION. FL#: FL14429 DATE: 10.16.17 DWG.BY: CHK. BY: SM HFN SCALE: NTS DWG.#: AWD191 SHEET: OF 7 #10 WOOD SCREW INSTALLATION ANCHOR CONCRETE/ MASONRY BY OTHERS SEALANT BETWEEN CONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS 2XWOOD BUCK BY OTHERS EXTERIOR FINISH BY OTHERS SEALANT BETWEEN FLANGE AND 2X WOOD PERIMETER SEALANT BY OTHERS O.A. UNIT HEIGHT l EXTERIOR NOTE: FLANGE MAY BE TRIMMED/CUT DOWN TO FIT WOOD BUCK OR REMOVED FOR DIRECT TO MASONRY INSTALLATION. 1-1/2" MIN. EMBEDMENT 3/8" MAX. SHIM SPACE ,---SEE GLAZING DETAILS, SHEET 8 INTERIOR ffi VERTICAL SECTION 3 HEAD -2X WOOD/CONCRETE/MASONRY THROUGH FRAME EXTERIOR 1 INTERIOR I EXTERIOR O.A. UNIT HEIGHT SET SILL IN BED OF STRUCTURAL SILICONE SEALANT (MIN THREE½" BEADS) SEE GLAZING DETAILS, O.A. SEE GLAZING SHEETS UNIT HEIGHT SET SILL IN BED OF STRUCTURAL SILICONE SEALANT (MIN THREE½" BEADS) EXTERIOR DETAILS, SHEETS #10 WOOD SCREW INSTALLATION ANCHOR 2X WOOD FRAMING & SHEATHING BY OTHERS EXTERIOR FINISH BY OTHERS SEALANT BETWEEN FLANGE AND SUBSTRATE PERIMETER SEALANT BY OTHERS I O.A. UNIT HEIGHT l EXTERIOR SEE GLAZING DETAILS, SHEET 8 INTERIOR VERTICAL SECTION HEAD· 2X WOOD FRAMING THROUGH FRAME INTERIOR I EXTERIOR O.A. SEE GLAZING UNIT HEIGHT SET SILL IN BED OF STRUCTURAL SILICONE SEALANT (MIN THREE½" BEADS) EXTERIOR DETAILS, SHEETS 3/4" MIN EDGE DISTANCE 1-1/2" MIN. EMBEDMENT 3/8" MAX. SHIM SPACE INTERIOR CONCRETE/ MASON RY BY OTHERS FINISH/BLOCKING/DECKING .....,ic;.:_;_:..:..:.;;.;..:..:~c..::::::::::.... _____ __::::::::..1 FINISH/BLOCKING/DECKING .....,ic;.:_;_:..:..:.;;.;..:..:-:;, ,..;..;i _c:;; _:::: _::::: _-_-_-_-_-_-_-_-_-_-_-_-_..: _::: -~ ffi VERT~~;;!,~TION THROUGH FRAME BY OTHERS 2X WOOD FRAMING BY OTHERS Ci) VERTICAL SECTION STANDARD SIU.-2X WOOD THROUGH FRAME BY OTHERS 2X WOOD FRAMING BY OTHERS (]) SEE DP TABLE, SHEET 1, FOR RATINGS REQUIRING DPUP SILL VERTICAL SECTION DPUP SIU.· 2X WOOD THROUGH FRAME Andersen WINDOWS• D OO RS 100 FOURTH AVE NORTH BAYPORT, MN 5S003-1096 PH: j651) 264-5150 FX: (651) 264-5485 REMARKS BY DATE I UMENT I THE PEIITT' f BUILDIN D I AND SHAil NOT BE REPRODUCED IN WHOl.E OR PAl!T WITHOUT WRITTEN CONSENT OF BUIIDING DROPS, INC. ALTERATIONS, ADDmONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOaJMENT ARE NOT PERMITTED AND INVALIDATE OUR CEl!TlFICATION. FL#: FL14429 DATE: lQ.16.17 DWG. BY: CHK. BY: SM HFN SCALE: NTS DWG. #: AWD191 SHEET: OF 7 METAL STUD & SHEATHING FRAMING BY OTHERS #10 SELF-DRILLING SCREW INSTALLATION ANCHOR SEALANT BETWEEN FLANGE AND SUBSTRATE EXTERIOR FINISH BY OTHERS PERIMETER SEALANT BY OTHERS O.A. UNIT HEIGHT EXTERIOR SEE GLAZING DETAILS, SHEET 8 1 O.A. UNIT HEIGHT SET SI LL IN BED OF STRUCTURAL SILICONE SEALANT (MIN THREE½" BEADS) CONCRETE/ MASONRY BY OTHERS EXTERIOR CI) 3 4" MIN ED E DISTANCE INTERIOR VERTICAL SECTION HEAD -METAL SUBSTRATE THROUGH FRAME INTERIOR VERTICAL SECTION SILL -CONCRETE THROUGH FRAME THREE THREADS MIN. PENETRATION BEYOND METAL 3/8" MAX. SHIM SPACE 3/4" 0.A. INSULATED TEMPERED GLASS EXTERIOR INTERIOR ' ' \ 3/4" GLASS BITE DESICCANT FILLED SILICONE BACK BED METAL SPACER GLAZING DETAIL 1 NOTE: GLASS THICKNESS SHALL COMPLY WITH ASTM E1300 REQUIREMENTS WIN D OW S • D OOR S 100 FOURTH AVE NORTH BAYPORT, MN S5003-1096 PH: (651) 264-5150 FX: (651) 264-5485 REMARKS BY DATE HI D ClJMENT I THE PERTY F BUIIDIN D INC AND SHAU. NDT BE REPRODUCED IN WHOLE OIi PART WIJHOUT WRITTEN CONSENT OF BUILDING DROPS, INC. AL TERATlONS, ADDITIONS, HIGHLIGHTING, OR OTliER MARKINGS TO THIS DOCUMENT ARENDT PERMITTED AND INVALIDATE OUR CElnlFICATION. FL#: FL14429 DATE: lQ.16.17 DWG. BY: CHK. BY: SM HFN SCALE: NTS DWG.#: AWD191 SHEET: OF 7 3 THREADS MIN. PENETRATION BEYOND METAL METAL STUD FRAMING BY OTHERS 3/8" MAX. .....:...--,~-.iii, r SHIM SPACE #10 SELF-DRILLING SCREW ~ INSTALLATION ANCHOR ! 1....&hl .. / .. ~ 3/4" MIN. EDGE DISTANCE SHEATHING BY OTHERS SEALANT BETWEEN FLANGE AND SUBSTRATE EXTERIOR FINISH BY OTHERS PERIMETER SEALANT BY OTHERS O.A. UNIT WIDTH HORIZONTAL SECTION 3/8" MAX. SHIM SPACE 1-1/2" MIN. EMBEDMENT . . . : . . ~·- JAMB -METAL 51\JD FRAME THROUGH FRAME INTERIOR SEE GLAZING DETAILS, SHEET 8 EXTERIOR INTERIOR SEE GLAZING DETAILS, SHEET 8 EXTERIOR t ,.. ., .. : .. : INTERIOR 2" MIN EDGE DISTANCE t ffi .. -. · .. •. O.A. UNIT WIDTH HORIZONTAL SECTION JAMB -1X WOOD/CONCRETE/MASONRY THROUGH FRAME SEE GLAZING DETAILS, SHEET 8 EXTERIOR SEE GLAZING DETAILS, SHEET 8 NOTE: FLANGE MAY BE TRIMMED/CUT DOWN TO FIT lX BUCK OR REMOVED FOR DIRECT TO MASONRY INSTALLATION. 3/8" MAX. SHIM SPACE / O.A. UNIT WIDTH 1-1/2" MIN. EMBEDMENT SEALANT BETWEEN CONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS 3/4" MIN. EDGE DISTANCE • , • #10 WOOD SCREW .: . • INSTALLATION ANCHOR :.·. < 2XWOOD BUCK . :. BY OTHERS : : . : . . . SEALANT BETWEEN l& FLANGE AND SUBSTRATE . : -:-: . EXTERIOR FINISH . . . . . . . . BYOTHERS PERIMETER SEALANT BY OTHERS HORIZONTAL SECTION JAMB -ZX WOOD BUCK THROUGH FRAME INTERIOR EXTERIOR HORIZONTAL SECTION INTERLOCK WIN D OW S • D OOR S 100 FOURTH AVE NORTH BAYPORT, MN S5003-1096 PH: (651) 264-5150 FX: (651) 264-5485 REMARKS BY DATE HI D ClJMENT I THE PERTY F BUIIDIN D INC AND SH,l,ll. NOT BE REPRODUCED IN WHOLE Of\ PART WIJHOUT WRITTEN CONSENT OF BUILDING DROPS, INC. ALTERAllC)tjS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVAUDATE OUR a1mF1CATION. FL#: FL14429 DATE: lQ.16.17 DWG. BY: CHK. BY: SM HFN SCALE: NTS DWG.#: AWD191 SHEET: OF 7 L-MULL W -TRIBUTARY WIDTH (IN) LENGTH (IN) 18.0 21.0 24.0 27.0 30.0 "-0 36.0 39.0 42.0 45.0 48.0 36.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 42.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 48.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 54.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 60.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 66.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.8 47.8 46.1 44.8 72.0 50.0 50.0 50.0 50.0 50.0 49.3 46.5 44.1 42.2 40.6 39.2 78.0 50.0 50.0 50.0 50.0 47.8 44.5 41.8 39.6 37.7 36.2 34.8 B4.0 50.0 50.0 50.0 47.5 43.6 40.6 38.0 35.9 34.1 32.6 31.4 90.0 50.0 50.0 48.3 43.7 40.1 37.2 34.8 32.9 31.2 29.7 28.5 96.0 50.0 50.0 44.8 40.6 37.2 34.4 32.2 30.3 28.7 27.3 26.1 NOTE: 1) MULLION CHART APPLIES TO MULLION ASSEMBLIES, SEE TYP. DETAILA/9, WHEN USED TO MULL DOORS IN CONFIGURATIONS SHOWN IN TYP. ELEVATION A AT RIGHT (2 PANEL XO ONLY), 2) DESIGN PRESSURE VALUES ARE POSITIVE AND NEGATIVE IN PSF. 3) MAXIMUM DEFLECTION HAS BEEN LIMITED TO L/175. 4) DESIGN PRESSURE OF ASSEMBLY IS LIMITED TO THE LESSER DESIGN PRESSURE OF THE JAMB-TO-JAMB WOOD MUWON OR THE INDIVIDUAL DOOR UNIT OF INSTALLATION. 5) MULLION CHART ABOVE APPLIES TO MULLED ASSEMBLIES CONSISTING OF 200 SERIES PERMA-SHIELD GLIDING PATIO DOOR ACT-STAT UNITS AND STAT UNITS. 6) ADJACENT DOORS SHALL BE FASTENED TO THE ROUGH OPENING WITH ADDITIONAL ANCHORS IN ACCORDANCE WITH DETAILS A/7 & B/7, SHEET 7. 200 SERIES PSGPD r L A OORX ELEVATION A TRIBUTARY WIDTH = W = (A+B)/2 #10 X 1 5/8" SCREWS 15" MAX. O.C., THROUGH EA. JAMB 1" OFFSET EXTERIOR VINYL TRIM STRIP BEAD OF SILICONE ORIZONTAL SECTION PSGPD STAT-PSGPD 200 SERIES PSGPD STAT WIN D OW S • D OOR S 100 FOURTH AVE NORTH BAYPORT, MN S5003-1096 PH: (651) 264-5150 FX: (651) 264-5485 REMARKS ~ ~ C z 0 ::J .... :::, :ii: BY DATE HI D ClJMENT I THE PERTY F BUIIDIN D INC AND SH,l,ll. NOT BE REPRODUCED IN WHOLE Of\ PART WIJHDUT WRITTEN CONSENT DF BUILDING DROPS. INC. ALTERATIC)tj5_ ADDITIONS. HIGHLIGHTING, DR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVAUDATE OUR a1mF1CATION. FL#: FL14429 DATE: lQ.16.17 DWG. BY: CHK. BY: SM HFN SCALE: NTS DWG. #: AWD191 SHEET: OF 7 9"MAX. 3" MIN. O.C. 200 SERIES PSGPD 200 SERIES PSGPD 311 MIN.O.C. 9"MAX. (!) 9"MAX. 3" MIN.O.C. EXTERIOR VIEW MULUON ANCHOR DETAIL· HEAD THROUGH FRAME -TVP. THREE (3) INSTALLATION ANCHORS THROUGH EA. FRAME SEE SHEET 1,INSTALLATION NOTES 4, S, OR 6 WHERE APPLICABLE 200 SERIES PSGPD STAT 200 SERIES PSGPD STAT THREE (3) INSTALLATION ANCHORS THROUGH EA. FRAME SEE SHEETl,INSTALLATION NOTES 4, 5, OR 6 WHERE APPLICABLE 3" MIN.O.C. 9"MAX. EXTERIOR VIEW MULLION ANCHOR DETAIL• SILL THROUGH FRAME -TVP. WIN D OW S • D OOR S 100 FOURTH AVE NORTH BAYPORT, MN S5003-1096 PH: (651) 264-5150 FX: (651) 264-5485 REMARKS ~ ii: 0 ::c u z < z 0 ::J .... ::, ::E BY DATE HI D ClJMENT I THE PERTY F BUIIDIN D INC AND SW.U. NOT BE REPRODUCED IN WHOLE Of\ PART WIJHDUT WRITTEN CONSENT OF BUILDING DROPS, INC. ALTERAllC)tjS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVAUDATE OUR a1mF1CATION. FL#: FL14429 DATE: lQ.16.17 DWG. BY: CHK. BY: SM HFN SCALE: NTS DWG. #: AWD191 SHEET: 71 OF 7 7/4/2018 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquiKNpeAsu%2bZPP3j%2ba4esDUpCg99bjsFkZi4GyBlTrjlg%3d%3d 1/3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL14429-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Andersen Corporation Address/Phone/Email 100 Fourth Avenue North Bayport, MN 55003 (651) 264-5308 alan.barstad@AndersenCorp.com Authorized Signature Alan Barstad alan.barstad@AndersenCorp.com Technical Representative Address/Phone/Email Quality Assurance Representative Alan Barstad Address/Phone/Email 100 Fourth Avenue North Bayport, MN 55003 (651) 264-5308 abarstad@andersencorp.com Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Hermes F. Norero, P.E. Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL14429_R6_COI_COI Andersen SS 2015-08-31.pdf Referenced Standard and Year (of Standard)Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 AAMA/WDMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E 1886 2002 ASTM E 1886 2005 ASTM E 1996 2012 ASTM E 1996 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 RES20-0261 FLCAIQA CGPARTMINT OF Business & Professional Regulation ► OFFICE OF THE SECRETARY D D ~ 7/4/2018 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquiKNpeAsu%2bZPP3j%2ba4esDUpCg99bjsFkZi4GyBlTrjlg%3d%3d 2/3 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/21/2017 Date Validated 10/21/2017 Date Pending FBC Approval 10/26/2017 Date Approved 12/12/2017 Summary of Products FL #Model, Number or Name Description 14429.1 100 Series Gliding Patio Doors Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Refer to pressure tables on drawing AWD120 (Note: All pressures meet water infiltration requirements) Installation Instructions FL14429_R6_II_AWD120 SS 2017-10-20.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. #73778 Created by Independent Third Party: Yes Evaluation Reports FL14429_R6_AE_PER4968 SS 2017-10-20.pdf Created by Independent Third Party: Yes 14429.2 200 Series Narroline Gliding Patio Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to pressure tables on drawing AWD112 (Note: All pressures meet water infiltration requirements) Installation Instructions FL14429_R6_II_AWD112 SS 2017-10-20.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14429_R6_AE_PER5174 SS 2017-10-20.pdf Created by Independent Third Party: Yes 14429.3 200 Series Perma-Shield Gliding Patio Doors Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to pressure tables on drawing AWD191 (Note: All pressures meet water infiltration requirements) Installation Instructions FL14429_R6_II_AWD191 SS 2017-10-20.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14429_R6_AE_PER5175 SS 2017-10-20.pdf Created by Independent Third Party: Yes 14429.4 400 Series Frenchwood Gliding Patio Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to pressure tables on drawing AWD117 (Note: All pressures meet water infiltration requirements) Installation Instructions FL14429_R6_II_AWD117 SS 2017-10-20.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. #73778 Created by Independent Third Party: Yes Evaluation Reports FL14429_R6_AE_PER4965 SS 2017-10-20.pdf Created by Independent Third Party: Yes 14429.5 A Series FWGPD Gliding Patio Doors Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Refer to pressure tables on drawing AWD118 (Note: All pressures meet water infiltration requirements). Plastic Material Certification of laminated glazing interlayers are listed under current Miami-Dade NOAs. Installation Instructions FL14429_R6_II_AWD118 SS 2017-10-20.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. #73778 Created by Independent Third Party: Yes Evaluation Reports FL14429_R6_AE_PER4966 SS 2017-10-20.pdf Created by Independent Third Party: Yes 14429.6 A Series FWGPD DP Upgrade Gliding Patio Doors Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Installation Instructions FL14429_R6_II_AWD119 SS 2017-10-20.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports Renewal byAndersen . Order Summary dba: RENEWAL BY ANDERSEN OF FLORIDA Legal Name: JLM W indows. LLC I License# CGC 1527613 997 West Kenne dy Blvd. Ste A-18 I Orland o. FL 3 2810 Phone: 407-8 03-4723 I Fax : 407-386-8262 I concier ge@rba f la.com Measure Tech: Johnny Lee. HELEN BRADLEY 94 Oceanside Drive Atlantic Beach. FL 32233 H: (904)247-3377 IC: ID# ROOM SIZE DETAILS JOB 101 Office 70-3/4" 70-3/4" 78-3/4 " 78-3/4" Patio Door: Gliding, 200 Ser i es Perma-Shield, 2 Panel, St ationary I Active, Exterior White, In t erior White Glass: All Sas h : Tempe red High Pert. SmartS u n Glass Hardware: Alb any, Whit e, Auxilia ry Foot Lock Color Matched Screen: No Screen Grille Style: No Grille Misc: None Construction: None Material: Caulk-White Exterior (1), 2.25" x 5/8" L-Trim, (12 f t), White (3) PRODUCTS: 1 WINDOWS: 0 PATIO DOORS: 1 SPEC I ALTY: 0 MISC: 0 Updated 8/13/20 JOB NOTES Estimated Duration: FLOORPLAN -1ST FLOOR ,-------------------., ✓ 101 1..------... UNIT NOTES FRONT JOB PHOTOS 0 8 /1 3 /2 0 Page 2 / 6