49 Dudley St RES20-0172 15 of 17 truss calcs_1Site Information: Customer:Accu-Span Truss Company Job Number: Address:City, State, Zip: 21190 PARCEL 3 DUTTON ISLAND JobDescription:MODEL 1891A /MODEL 1891A -Pinnacle Homes Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone: (800)755-6001 www.alpineitw.com Address:City, State, Zip: Name:License #:State: Name, Address and License # of Structural EOR if one exists for the building: Job Engineering Criteria: ASCE 7-10Wind Standard: FBC 2017 RESDesign Code: 140Wind Speed (mph): 17.02.01.1114.21View Version: 20.00- 7.00- 0.00- 10.00 Roof Load (psf):NoneFloor Load (psf): This package contains a job notes page, 29 truss drawings and 6 details. JRef #:1W dP4080027 Item Seal #Truss Item Seal #Truss A1 A3 A5G B01 B03 CJ2A CJ4A EJ6A FG2 FT1GE FT2A FT3 FT4B HJ6 FT6 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 233.18.1627.19579 233.18.1627.19844 233.18.1627.19749 233.18.1627.20000 233.18.1627.19984 233.18.1627.19830 233.18.1627.19719 233.18.1627.19704 233.18.1627.20030 233.18.1627.19688 233.18.1627.19953 233.18.1627.19985 233.18.1627.19874 233.18.1627.19533 234.18.0815.21983 A2 A4 A6G B02 CJ2 CJ4 EJ6 FG1 FT1 FT2 FT3 FT4 FT4GE HJ6A 2 4 6 8 10 12 14 16 18 20 22 24 26 28 233.18.1627.19625 233.18.1627.19549 233.18.1627.19766 233.18.1627.19954 233.18.1627.19548 233.18.1627.19829 233.18.1627.19594 233.18.1627.20016 233.18.1627.19689 233.18.1627.19845 233.18.1627.19690 233.18.1627.19875 233.18.1627.19532 233.18.1627.19828 Printed 8/22/2018 10:28:32 AMFlorida Certificate of Product Approval #FL1999 08/22/2018 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 413 / 457 / -/ 94 / 5.5 F 975 / 413 / 457 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1657 -2306 C - D 1316 -1885 Chords Tens.Comp. D - E 1316 -1885 E - F 1657 -2306 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2167 -1503 I - H 1372 -873 Chords Tens.Comp. H - F 2167 -1512 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 500 -476 I - D 562 -248 Webs Tens.Comp. D - H 562 -248 H - E 500 -476 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.79 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.113 D 999 240 VERT(TL):0.302 D 999 180 HORZ(LL):0.035 H - - HORZ(TL):0.064 H - - Creep Factor: 2.0 Max TC CSI:0.564 Max BC CSI:0.715 Max W eb CSI:0.214 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A1 Ply: 1 Qty:14 SEQN:106240 /T2 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19579 KM /WHK 08/21/2018 18'7"A B C D E F G HI 4 12 3X4(A1) 2X4 5X6 4X6(R1) 5X6 2X4 3X4(A1) 24'6" 4'5"11 4'5"11 12'3" 7'9"4 20'0"4 7'9"4 24'6" 4'5"12 8' 8' 16'6" 8'6" 24'6" 8'1'1' 3"15 4 '4 "1 5 4 '8 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 413 / 457 / -/ 94 / 5.5 F 975 / 413 / 457 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1657 -2306 C - D 1316 -1885 Chords Tens.Comp. D - E 1316 -1885 E - F 1657 -2306 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2167 -1503 I - H 1372 -873 Chords Tens.Comp. H - F 2167 -1512 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 500 -476 I - D 562 -248 Webs Tens.Comp. D - H 562 -248 H - E 500 -476 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.79 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.113 D 999 240 VERT(TL):0.302 D 999 180 HORZ(LL):0.035 H - - HORZ(TL):0.064 H - - Creep Factor: 2.0 Max TC CSI:0.564 Max BC CSI:0.715 Max W eb CSI:0.214 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A1 Ply: 1 Qty:14 SEQN:106240 /T2 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19579 KM /WHK 08/21/2018 18'7"A B C D E F G HI 4 12 3X4(A1) 2X4 5X6 4X6(R1) 5X6 2X4 3X4(A1) 24'6" 4'5"11 4'5"11 12'3" 7'9"4 20'0"4 7'9"4 24'6" 4'5"12 8' 8' 16'6" 8'6" 24'6" 8'1'1' 3"15 4 '4 "1 5 4 '8 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 406 / 457 / -/ 92 / 5.5 F 975 / 406 / 457 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1639 -2306 C - D 1286 -1885 Chords Tens.Comp. D - E 1286 -1885 E - F 1639 -2306 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2167 -1487 I - H 1372 -845 Chords Tens.Comp. H - F 2167 -1495 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 509 -476 I - D 562 -253 Webs Tens.Comp. D - H 562 -253 H - E 509 -476 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: No FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.113 D 999 240 VERT(TL):0.302 D 999 180 HORZ(LL):0.035 H - - HORZ(TL):0.064 H - - Creep Factor: 2.0 Max TC CSI:0.564 Max BC CSI:0.715 Max W eb CSI:0.214 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A2 Ply: 1 Qty:1 SEQN:106246 /T18 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19625 KM /WHK 08/21/2018 18'7"A B C D E F G HI 4 12 3X4(A1) 2X4 5X6 6X6 5X6 2X4 3X4(A1) 24'6" 4'5"11 4'5"11 12' 7'6"4 20'0"4 8'0"4 24'6" 4'5"12 8' 8' 16'6" 8'6" 24'6" 8'1'1' 3"15 4 '3 "1 5 4 '7 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 406 / 457 / -/ 92 / 5.5 F 975 / 406 / 457 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1639 -2306 C - D 1286 -1885 Chords Tens.Comp. D - E 1286 -1885 E - F 1639 -2306 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2167 -1487 I - H 1372 -845 Chords Tens.Comp. H - F 2167 -1495 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 509 -476 I - D 562 -253 Webs Tens.Comp. D - H 562 -253 H - E 509 -476 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: No FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.113 D 999 240 VERT(TL):0.302 D 999 180 HORZ(LL):0.035 H - - HORZ(TL):0.064 H - - Creep Factor: 2.0 Max TC CSI:0.564 Max BC CSI:0.715 Max W eb CSI:0.214 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A2 Ply: 1 Qty:1 SEQN:106246 /T18 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19625 KM /WHK 08/21/2018 18'7"A B C D E F G HI 4 12 3X4(A1) 2X4 5X6 6X6 5X6 2X4 3X4(A1) 24'6" 4'5"11 4'5"11 12' 7'6"4 20'0"4 8'0"4 24'6" 4'5"12 8' 8' 16'6" 8'6" 24'6" 8'1'1' 3"15 4 '3 "1 5 4 '7 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 406 / 471 / -/ 80 / 5.5 G 975 / 406 / 471 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 G Min Brg Width Req =1.5 Bearings B & G are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1523 -2133 C - D 1215 -1739 D - E 1210 -1613 Chords Tens.Comp. E - F 1208 -1729 F - G 1523 -2130 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1992 -1356 J - I 1611 -964 Chords Tens.Comp. I - G 1990 -1364 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 424 -412 Webs Tens.Comp. I - F 429 -419 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.41 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.105 J 999 240 VERT(TL):0.282 J 999 180 HORZ(LL):0.035 I - - HORZ(TL):0.064 I - - Creep Factor: 2.0 Max TC CSI:0.369 Max BC CSI:0.827 Max W eb CSI:0.210 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A3 Ply: 1 Qty:1 SEQN:106249 /T17 /HIPS FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19844 KM /WHK 08/21/2018 18'7"A B C D E F G H IJ 4 12 3X4(A1) 2X4 4X6 3X4 5X6 4X6 2X4 3X4(A1) 24'6" 5'6"8 5'6"8 10' 4'5"8 14'6" 4'6" 18'11"9 4'5"8 24'6" 5'6"7 10' 10' 14'4"4 4'4"4 24'6" 10'1"121'1' 3"15 3 '7 "1 5 3 '1 1 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 406 / 471 / -/ 80 / 5.5 G 975 / 406 / 471 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 G Min Brg Width Req =1.5 Bearings B & G are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1523 -2133 C - D 1215 -1739 D - E 1210 -1613 Chords Tens.Comp. E - F 1208 -1729 F - G 1523 -2130 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1992 -1356 J - I 1611 -964 Chords Tens.Comp. I - G 1990 -1364 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 424 -412 Webs Tens.Comp. I - F 429 -419 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.41 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.105 J 999 240 VERT(TL):0.282 J 999 180 HORZ(LL):0.035 I - - HORZ(TL):0.064 I - - Creep Factor: 2.0 Max TC CSI:0.369 Max BC CSI:0.827 Max W eb CSI:0.210 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A3 Ply: 1 Qty:1 SEQN:106249 /T17 /HIPS FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19844 KM /WHK 08/21/2018 18'7"A B C D E F G H IJ 4 12 3X4(A1) 2X4 4X6 3X4 5X6 4X6 2X4 3X4(A1) 24'6" 5'6"8 5'6"8 10' 4'5"8 14'6" 4'6" 18'11"9 4'5"8 24'6" 5'6"7 10' 10' 14'4"4 4'4"4 24'6" 10'1"121'1' 3"15 3 '7 "1 5 3 '1 1 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 400 / 480 / -/ 67 / 5.5 F 975 / 400 / 480 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1356 -2031 C - D 1350 -2007 Chords Tens.Comp. D - E 1350 -2007 E - F 1356 -2031 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1872 -1166 J - I 1881 -1167 Chords Tens.Comp. I - H 1881 -1176 H - F 1871 -1174 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.08 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.114 D 999 240 VERT(TL):0.305 D 999 180 HORZ(LL):0.034 H - - HORZ(TL):0.062 H - - Creep Factor: 2.0 Max TC CSI:0.710 Max BC CSI:0.675 Max W eb CSI:0.111 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A4 Ply: 1 Qty:1 SEQN:106252 /T16 /HIPS FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19549 KM /WHK 08/21/2018 18'7"A B C D E F G HIJ 4 12 3X4(A1) 4X8 2X4 2X4 5X6 2X4 4X8 3X4(A1) 24'6" 8' 8' 12'3" 4'3" 16'6" 4'3" 24'6" 8' 8'1"12 8'1"12 12'3" 4'1"4 16'4"4 4'1"4 24'6" 8'1"121'1' 3"15 2 '1 1 "1 5 3 '3 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 975 / 400 / 480 / -/ 67 / 5.5 F 975 / 400 / 480 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1356 -2031 C - D 1350 -2007 Chords Tens.Comp. D - E 1350 -2007 E - F 1356 -2031 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1872 -1166 J - I 1881 -1167 Chords Tens.Comp. I - H 1881 -1176 H - F 1871 -1174 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.08 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.114 D 999 240 VERT(TL):0.305 D 999 180 HORZ(LL):0.034 H - - HORZ(TL):0.062 H - - Creep Factor: 2.0 Max TC CSI:0.710 Max BC CSI:0.675 Max W eb CSI:0.111 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A4 Ply: 1 Qty:1 SEQN:106252 /T16 /HIPS FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19549 KM /WHK 08/21/2018 18'7"A B C D E F G HIJ 4 12 3X4(A1) 4X8 2X4 2X4 5X6 2X4 4X8 3X4(A1) 24'6" 8' 8' 12'3" 4'3" 16'6" 4'3" 24'6" 8' 8'1"12 8'1"12 12'3" 4'1"4 16'4"4 4'1"4 24'6" 8'1"121'1' 3"15 2 '1 1 "1 5 3 '3 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense :T2 2x4 SP #1 Dense: Bot chord 2x4 SP #1 Dense Webs 2x4 SP #3 Loading #1 hip supports 6-0-0 jacks with no webs. Left side jacks have 6-0-0 setback with 0-0-0 cant and 1-0-0 overhang. End jacks have 6-0-0 setback with 0-0-0 cant and 1-0-0 overhang. Right side jacks have 6-0-0 setback with 0-0-0 cant and 1-0-0 overhang. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 1710 / 687 / -/ -/ -/ 5.5 G 1710 / 687 / -/ -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.7 G Min Brg Width Req =1.7 Bearings B & G are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1716 -4358 C - D 2081 -5333 D - E 2081 -5333 Chords Tens.Comp. E - F 2057 -5288 F - G 1716 -4357 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 4088 -1595 L - K 4119 -1598 K - J 5348 -2101 Chords Tens.Comp. J - I 4118 -1599 I - G 4087 -1596 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 431 -46 C - K 1348 -536 D - K 304 -417 Webs Tens.Comp. E - J 308 -431 J - F 1308 -512 I - F 426 -45 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: No FT/RT:0(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.310 E 938 240 VERT(TL):0.842 E 504 180 HORZ(LL):0.070 I - - HORZ(TL):0.130 I - - Creep Factor: 2.0 Max TC CSI:0.814 Max BC CSI:0.885 Max W eb CSI:0.514 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A5G Ply: 1 Qty:1 SEQN:106260 /T20 /HIPS FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19749 KM /WHK 08/21/2018 T2 18'7"A B C D E F G H IJKL 4 12 3X8(A1) 5X8 2X4 2X4 3X10 3X4 H0510 2X4 5X8 3X8(A1) 24'6" 6' 6' 10'2"9 4'2"9 14'1"11 3'11"1 18'6" 4'4"5 24'6" 6' 6'1"12 6'1"12 10'2"9 4'0"13 14'6" 4'3"7 18'4"4 3'10"4 24'6" 6'1"121'1' 3"15 2 '3 "1 5 2 '7 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense :T2 2x4 SP #1 Dense: Bot chord 2x4 SP #1 Dense Webs 2x4 SP #3 Loading #1 hip supports 6-0-0 jacks with no webs. Left side jacks have 6-0-0 setback with 0-0-0 cant and 1-0-0 overhang. End jacks have 6-0-0 setback with 0-0-0 cant and 1-0-0 overhang. Right side jacks have 6-0-0 setback with 0-0-0 cant and 1-0-0 overhang. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 1710 / 687 / -/ -/ -/ 5.5 G 1710 / 687 / -/ -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.7 G Min Brg Width Req =1.7 Bearings B & G are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1716 -4358 C - D 2081 -5333 D - E 2081 -5333 Chords Tens.Comp. E - F 2057 -5288 F - G 1716 -4357 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 4088 -1595 L - K 4119 -1598 K - J 5348 -2101 Chords Tens.Comp. J - I 4118 -1599 I - G 4087 -1596 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 431 -46 C - K 1348 -536 D - K 304 -417 Webs Tens.Comp. E - J 308 -431 J - F 1308 -512 I - F 426 -45 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: No FT/RT:0(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.310 E 938 240 VERT(TL):0.842 E 504 180 HORZ(LL):0.070 I - - HORZ(TL):0.130 I - - Creep Factor: 2.0 Max TC CSI:0.814 Max BC CSI:0.885 Max W eb CSI:0.514 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A5G Ply: 1 Qty:1 SEQN:106260 /T20 /HIPS FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19749 KM /WHK 08/21/2018 T2 18'7"A B C D E F G H IJKL 4 12 3X8(A1) 5X8 2X4 2X4 3X10 3X4 H0510 2X4 5X8 3X8(A1) 24'6" 6' 6' 10'2"9 4'2"9 14'1"11 3'11"1 18'6" 4'4"5 24'6" 6' 6'1"12 6'1"12 10'2"9 4'0"13 14'6" 4'3"7 18'4"4 3'10"4 24'6" 6'1"121'1' 3"15 2 '3 "1 5 2 '7 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense Bot chord 2x6 SP #2 :B2, B4 2x4 SP #1 Dense: :B3 2x6 SP SS: Webs 2x4 SP #3 :W5 2x4 SP #1 Dense: Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 6.03 TC: From 27 plf at 6.03 to 27 plf at 18.47 TC: From 55 plf at 18.47 to 55 plf at 25.50 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 6.03 BC: From 10 plf at 6.03 to 10 plf at 18.47 BC: From 20 plf at 18.47 to 20 plf at 24.50 BC: From 4 plf at 24.50 to 4 plf at 25.50 TC: 286 lb Conc. Load at 6.03,18.47 TC: 142 lb Conc. Load at 8.06,10.06,12.06,12.44 14.44,16.44 BC: 253 lb Conc. Load at 6.03,18.47 BC: 106 lb Conc. Load at 8.06,10.06,12.06,12.44 14.44,16.44 Plating Notes All plates are 2X4 except as noted. (++) - This plate works for both joints covered. Wind Wind loads and reactions based on MWFRS. Additional Notes See DWGS A14030ENC101014 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W V 704 / 289 / -/ -/ -/ 5.5 N 2817 / 1059 / -/ -/ -/ 5.5 J 583 / 243 / -/ -/ -/ 3.5 Wind reactions based on MWFRS V Min Brg Width Req =1.5 N Min Brg Width Req =3.0 J Min Brg Width Req =1.5 Bearings V, N, & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 552 -1494 C - D 472 -1346 D - F 629 -216 Chords Tens.Comp. F - H 632 -217 H - I 250 -769 I - J 423 -1147 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 1397 -507 P - O 1398 -510 O - N 1164 -421 Chords Tens.Comp. N - M 1337 -463 M - L 1053 -380 L - J 1068 -384 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - Q 647 -97 Q - D 547 -58 Q - N 664 -1746 F - S 426 -872 Webs Tens.Comp. N - U 466 -1248 S - N 633 -1210 M - I 188 -432 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.79 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.066 N 999 240 VERT(TL):0.186 N 999 180 HORZ(LL):0.017 E - - HORZ(TL):0.031 E - - Creep Factor: 2.0 Max TC CSI:0.428 Max BC CSI:0.662 Max W eb CSI:0.939 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A6G Ply: 1 Qty:1 SEQN:106267 /T3 /GABL FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19766 KM /WHK 08/21/2018 B2 B3 B4W5(a) 18'7"A B C D F H I J K LMNOP Q S U V 4 12 2X4(A1) 3X4 7X8 3X8(++) 4X6(R1) 4X64X8 3X6(++) 7X8 3X4 2X4(A1) 12'9"4 11'8"12 4'2"6 4'2"6 10'3" 6'0"10 12'3" 2' 14'3" 2' 20'3"10 6'0"10 24'6" 4'2"6 4'0"10 4'0"10 6'1"4 2'0"10 10'3" 4'1"12 12'1"4 1'10"4 14'3" 2'1"12 18'4"12 4'1"12 20'5"6 2'0"10 24'6" 4'0"101'1' 3"15 2 '0 "7 4 '4 "1 5 4 '8 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense Bot chord 2x6 SP #2 :B2, B4 2x4 SP #1 Dense: :B3 2x6 SP SS: Webs 2x4 SP #3 :W5 2x4 SP #1 Dense: Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 6.03 TC: From 27 plf at 6.03 to 27 plf at 18.47 TC: From 55 plf at 18.47 to 55 plf at 25.50 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 6.03 BC: From 10 plf at 6.03 to 10 plf at 18.47 BC: From 20 plf at 18.47 to 20 plf at 24.50 BC: From 4 plf at 24.50 to 4 plf at 25.50 TC: 286 lb Conc. Load at 6.03,18.47 TC: 142 lb Conc. Load at 8.06,10.06,12.06,12.44 14.44,16.44 BC: 253 lb Conc. Load at 6.03,18.47 BC: 106 lb Conc. Load at 8.06,10.06,12.06,12.44 14.44,16.44 Plating Notes All plates are 2X4 except as noted. (++) - This plate works for both joints covered. Wind Wind loads and reactions based on MWFRS. Additional Notes See DWGS A14030ENC101014 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W V 704 / 289 / -/ -/ -/ 5.5 N 2817 / 1059 / -/ -/ -/ 5.5 J 583 / 243 / -/ -/ -/ 3.5 Wind reactions based on MWFRS V Min Brg Width Req =1.5 N Min Brg Width Req =3.0 J Min Brg Width Req =1.5 Bearings V, N, & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 552 -1494 C - D 472 -1346 D - F 629 -216 Chords Tens.Comp. F - H 632 -217 H - I 250 -769 I - J 423 -1147 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 1397 -507 P - O 1398 -510 O - N 1164 -421 Chords Tens.Comp. N - M 1337 -463 M - L 1053 -380 L - J 1068 -384 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - Q 647 -97 Q - D 547 -58 Q - N 664 -1746 F - S 426 -872 Webs Tens.Comp. N - U 466 -1248 S - N 633 -1210 M - I 188 -432 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 20.79 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.066 N 999 240 VERT(TL):0.186 N 999 180 HORZ(LL):0.017 E - - HORZ(TL):0.031 E - - Creep Factor: 2.0 Max TC CSI:0.428 Max BC CSI:0.662 Max W eb CSI:0.939 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:A6G Ply: 1 Qty:1 SEQN:106267 /T3 /GABL FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19766 KM /WHK 08/21/2018 B2 B3 B4W5(a) 18'7"A B C D F H I J K LMNOP Q S U V 4 12 2X4(A1) 3X4 7X8 3X8(++) 4X6(R1) 4X64X8 3X6(++) 7X8 3X4 2X4(A1) 12'9"4 11'8"12 4'2"6 4'2"6 10'3" 6'0"10 12'3" 2' 14'3" 2' 20'3"10 6'0"10 24'6" 4'2"6 4'0"10 4'0"10 6'1"4 2'0"10 10'3" 4'1"12 12'1"4 1'10"4 14'3" 2'1"12 18'4"12 4'1"12 20'5"6 2'0"10 24'6" 4'0"101'1' 3"15 2 '0 "7 4 '4 "1 5 4 '8 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See DWGS A14015ENC101014 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W B 195 / 58 / 114 / -/ 116 / 5.5 L*73 / 22 / 35 / -/ -/ 270 Wind reactions based on MWFRS B Min Brg Width Req =1.5 L Min Brg Width Req =- Bearings B & B are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.002 V 999 240 VERT(TL):0.006 V 999 180 HORZ(LL):0.001 N - - HORZ(TL):0.002 N - - Creep Factor: 2.0 Max TC CSI:0.087 Max BC CSI:0.075 Max W eb CSI:0.052 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:B01 Ply: 1 Qty:1 SEQN:891185 /T23 /GABL FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.20000 KM /DF 08/21/2018 9'1"2A B G L M R 4 12 2X4(A1) 4X4 5X6 2X4(A1) 23' 3'6"2' (TYP) 11'6" 11'6" 23' 11'6" 23' 23'1'1' 3"15 4 '1 "1 5 4 '5 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See DWGS A14015ENC101014 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W B 195 / 58 / 114 / -/ 116 / 5.5 L*73 / 22 / 35 / -/ -/ 270 Wind reactions based on MWFRS B Min Brg Width Req =1.5 L Min Brg Width Req =- Bearings B & B are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.002 V 999 240 VERT(TL):0.006 V 999 180 HORZ(LL):0.001 N - - HORZ(TL):0.002 N - - Creep Factor: 2.0 Max TC CSI:0.087 Max BC CSI:0.075 Max W eb CSI:0.052 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:B01 Ply: 1 Qty:1 SEQN:891185 /T23 /GABL FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.20000 KM /DF 08/21/2018 9'1"2A B G L M R 4 12 2X4(A1) 4X4 5X6 2X4(A1) 23' 3'6"2' (TYP) 11'6" 11'6" 23' 11'6" 23' 23'1'1' 3"15 4 '1 "1 5 4 '5 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 919 / 277 / 511 / -/ 116 / 5.5 F 919 / 277 / 511 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1278 -1978 C - D 1167 -1757 Chords Tens.Comp. D - E 1168 -1756 E - F 1278 -1976 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 1837 -1125 I - H 1255 -713 Chords Tens.Comp. H - F 1837 -1133 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. I - D 541 -305 Webs Tens.Comp. D - H 540 -306 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.092 I 999 240 VERT(TL):0.247 I 999 180 HORZ(LL):0.028 H - - HORZ(TL):0.052 H - - Creep Factor: 2.0 Max TC CSI:0.295 Max BC CSI:0.641 Max W eb CSI:0.206 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:B02 Ply: 1 Qty:4 SEQN:891182 /T11 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19954 KM /DF 08/21/2018 9'1"2A B C D E F G HI 4 12 3X4(A1) 2X4 3X4 4X4 5X6 2X4 3X4(A1) 23' 6'1"14 6'1"14 11'6" 5'4"2 16'10"2 5'4"2 23' 6'1"14 7'11"4 7'11"4 15'0"12 7'1"8 23' 7'11"41'1' 3"15 4 '1 "1 5 4 '5 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 919 / 277 / 511 / -/ 116 / 5.5 F 919 / 277 / 511 / -/ -/ 5.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 F Min Brg Width Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1278 -1978 C - D 1167 -1757 Chords Tens.Comp. D - E 1168 -1756 E - F 1278 -1976 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 1837 -1125 I - H 1255 -713 Chords Tens.Comp. H - F 1837 -1133 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. I - D 541 -305 Webs Tens.Comp. D - H 540 -306 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.092 I 999 240 VERT(TL):0.247 I 999 180 HORZ(LL):0.028 H - - HORZ(TL):0.052 H - - Creep Factor: 2.0 Max TC CSI:0.295 Max BC CSI:0.641 Max W eb CSI:0.206 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:B02 Ply: 1 Qty:4 SEQN:891182 /T11 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19954 KM /DF 08/21/2018 9'1"2A B C D E F G HI 4 12 3X4(A1) 2X4 3X4 4X4 5X6 2X4 3X4(A1) 23' 6'1"14 6'1"14 11'6" 5'4"2 16'10"2 5'4"2 23' 6'1"14 7'11"4 7'11"4 15'0"12 7'1"8 23' 7'11"41'1' 3"15 4 '1 "1 5 4 '5 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense :T2 2x4 SP #2 Dense: Bot chord 2x8 SP SS Webs 2x4 SP #3 :W7 2x4 SP #2 Dense: Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 2 Rows @ 3.00" o.c. (Each Row) Webs : 1 Row @ 4" o.c. Repeat nailing as each layer is applied. Use equal spacing between rows and stagger nails in each row to avoid splitting. In addition, apply (1) 0.22"-0.25" min/max dia. X 6.0" length wood screw at each joint location. 12" o.c. spacing of nails perpendicular and parallel to grain required in area over bearings greater than 12" Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 27 plf at 0.00 to 27 plf at 20.85 TC: From 55 plf at 20.85 to 55 plf at 24.00 BC: From 10 plf at 0.00 to 10 plf at 23.00 BC: From 4 plf at 23.00 to 4 plf at 24.00 BC: 2156 lb Conc. Load at 0.85, 2.85, 4.85, 6.85 BC: 1878 lb Conc. Load at 8.85,10.85,12.85 BC: 1869 lb Conc. Load at 14.85 BC: 1644 lb Conc. Load at 16.85 BC: 1159 lb Conc. Load at 18.85,20.85 Wind Wind loads and reactions based on MWFRS. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W R 12022 / 125 / -/ -/ -/ 5.5 I 9044 / 192 / -/ -/ -/ 5.5 Wind reactions based on MWFRS R Min Brg Width Req =3.5 I Min Brg Width Req =2.7 Bearings R & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 76 -7164 B - C 79 -7311 C - D 67 -5976 D - E 53 -4479 Chords Tens.Comp. E - F 53 -4479 F - G 68 -5628 G - H 80 -6368 H - I 78 -5920 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - Q 6801 -72 Q - P 6814 -72 P - O 6802 -74 O - N 5528 -62 Chords Tens.Comp. N - M 5230 -62 M - L 5974 -75 L - K 5656 -73 K - I 5616 -73 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. P - C 904 0 C - O 14 -1253 O - D 1479 -1 D - N 18 -1627 E - N 2775 -19 Webs Tens.Comp. N - F 18 -1247 F - M 1135 -2 M - G 14 -704 G - L 481 0 L - H 466 -2 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.252 N 999 360 VERT(TL):0.679 N 585 240 HORZ(LL):0.055 K - - HORZ(TL):0.101 K - - Creep Factor: 2.0 Max TC CSI:0.821 Max BC CSI:0.998 Max W eb CSI:0.705 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:B03 Ply: 4 Qty:1 SEQN:891226 /T22 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19984 KM /DF 08/21/2018 4 Complete Trusses Required T2W7 9'1"2 A B C D E F G H I J KLMNOPQR 4 12 4X12(A7R)2X4 3X4 5X6 4X4 5X6 4X6 4X6(R1) 10X12 3X6 4X6 3X4 4X6 3X4 2X4 4X10(A1) 23' 3'1"10 3'1"10 4'10"4 1'8"10 8'3" 3'4"12 11'6" 3'3" 14'9" 3'3" 18'1"12 3'4"12 19'10"6 1'8"10 23' 3'1"10 2'11"14 2'11"14 4'6"12 1'6"14 7'11"8 3'4"12 11'6" 3'6"8 15'0"8 3'6"8 18'5"4 3'4"12 20'0"2 1'6"14 23' 2'11"14 1' 3"15 4 '1 "1 5 4 '5 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense :T2 2x4 SP #2 Dense: Bot chord 2x8 SP SS Webs 2x4 SP #3 :W7 2x4 SP #2 Dense: Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 2 Rows @ 3.00" o.c. (Each Row) Webs : 1 Row @ 4" o.c. Repeat nailing as each layer is applied. Use equal spacing between rows and stagger nails in each row to avoid splitting. In addition, apply (1) 0.22"-0.25" min/max dia. X 6.0" length wood screw at each joint location. 12" o.c. spacing of nails perpendicular and parallel to grain required in area over bearings greater than 12" Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 27 plf at 0.00 to 27 plf at 20.85 TC: From 55 plf at 20.85 to 55 plf at 24.00 BC: From 10 plf at 0.00 to 10 plf at 23.00 BC: From 4 plf at 23.00 to 4 plf at 24.00 BC: 2156 lb Conc. Load at 0.85, 2.85, 4.85, 6.85 BC: 1878 lb Conc. Load at 8.85,10.85,12.85 BC: 1869 lb Conc. Load at 14.85 BC: 1644 lb Conc. Load at 16.85 BC: 1159 lb Conc. Load at 18.85,20.85 Wind Wind loads and reactions based on MWFRS. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W R 12022 / 125 / -/ -/ -/ 5.5 I 9044 / 192 / -/ -/ -/ 5.5 Wind reactions based on MWFRS R Min Brg Width Req =3.5 I Min Brg Width Req =2.7 Bearings R & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 76 -7164 B - C 79 -7311 C - D 67 -5976 D - E 53 -4479 Chords Tens.Comp. E - F 53 -4479 F - G 68 -5628 G - H 80 -6368 H - I 78 -5920 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - Q 6801 -72 Q - P 6814 -72 P - O 6802 -74 O - N 5528 -62 Chords Tens.Comp. N - M 5230 -62 M - L 5974 -75 L - K 5656 -73 K - I 5616 -73 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. P - C 904 0 C - O 14 -1253 O - D 1479 -1 D - N 18 -1627 E - N 2775 -19 Webs Tens.Comp. N - F 18 -1247 F - M 1135 -2 M - G 14 -704 G - L 481 0 L - H 466 -2 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.252 N 999 360 VERT(TL):0.679 N 585 240 HORZ(LL):0.055 K - - HORZ(TL):0.101 K - - Creep Factor: 2.0 Max TC CSI:0.821 Max BC CSI:0.998 Max W eb CSI:0.705 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:B03 Ply: 4 Qty:1 SEQN:891226 /T22 /COMN FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19984 KM /DF 08/21/2018 4 Complete Trusses Required T2W7 9'1"2 A B C D E F G H I J KLMNOPQR 4 12 4X12(A7R)2X4 3X4 5X6 4X4 5X6 4X6 4X6(R1) 10X12 3X6 4X6 3X4 4X6 3X4 2X4 4X10(A1) 23' 3'1"10 3'1"10 4'10"4 1'8"10 8'3" 3'4"12 11'6" 3'3" 14'9" 3'3" 18'1"12 3'4"12 19'10"6 1'8"10 23' 3'1"10 2'11"14 2'11"14 4'6"12 1'6"14 7'11"8 3'4"12 11'6" 3'6"8 15'0"8 3'6"8 18'5"4 3'4"12 20'0"2 1'6"14 23' 2'11"14 1' 3"15 4 '1 "1 5 4 '5 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 160 / 69 / 100 / -/ 39 / 5.5 D 30 / 3 / 25 / -/ -/ 1.5 C 32 / 19 / 9 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.08 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.000 D - - HORZ(TL):0.000 D - - Creep Factor: 2.0 Max TC CSI:0.130 Max BC CSI:0.024 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ2 Ply: 1 Qty:6 SEQN:106183 /T5 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19548 KM /WHK 08/21/2018 18'7" 19'3"7 A B C D 4 12 2X4(A1) 2' 2'1' 3"15 1 1 "1 5 1 '3 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 160 / 69 / 100 / -/ 39 / 5.5 D 30 / 3 / 25 / -/ -/ 1.5 C 32 / 19 / 9 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.08 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.000 D - - HORZ(TL):0.000 D - - Creep Factor: 2.0 Max TC CSI:0.130 Max BC CSI:0.024 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ2 Ply: 1 Qty:6 SEQN:106183 /T5 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19548 KM /WHK 08/21/2018 18'7" 19'3"7 A B C D 4 12 2X4(A1) 2' 2'1' 3"15 1 1 "1 5 1 '3 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 160 / 69 / 100 / -/ 39 / 3.5 D 30 / 3 / 25 / -/ -/ 1.5 C 32 / 19 / 9 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.08 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.000 D - - HORZ(TL):0.000 D - - Creep Factor: 2.0 Max TC CSI:0.130 Max BC CSI:0.024 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ2A Ply: 1 Qty:2 SEQN:106198 /T7 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19830 KM /WHK 08/21/2018 18'7" 19'3"7 A B C D 4 12 2X4(A1) 2' 2'1' 3"15 1 1 "1 5 1 '3 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 160 / 69 / 100 / -/ 39 / 3.5 D 30 / 3 / 25 / -/ -/ 1.5 C 32 / 19 / 9 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.08 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.000 D - - HORZ(TL):0.000 D - - Creep Factor: 2.0 Max TC CSI:0.130 Max BC CSI:0.024 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ2A Ply: 1 Qty:2 SEQN:106198 /T7 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19830 KM /WHK 08/21/2018 18'7" 19'3"7 A B C D 4 12 2X4(A1) 2' 2'1' 3"15 1 1 "1 5 1 '3 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 224 / 85 / 131 / -/ 66 / 5.5 D 69 / 6 / 48 / -/ -/ 1.5 C 89 / 54 / 22 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.41 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.002 D - - HORZ(TL):0.004 D - - Creep Factor: 2.0 Max TC CSI:0.240 Max BC CSI:0.158 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ4 Ply: 1 Qty:6 SEQN:106186 /T4 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19829 KM /WHK 08/21/2018 18'7" 19'11"7 A B C D 4 12 2X4(A1) 4' 4'1' 3"15 1 '7 "1 5 1 '1 1 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 224 / 85 / 131 / -/ 66 / 5.5 D 69 / 6 / 48 / -/ -/ 1.5 C 89 / 54 / 22 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.41 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.002 D - - HORZ(TL):0.004 D - - Creep Factor: 2.0 Max TC CSI:0.240 Max BC CSI:0.158 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ4 Ply: 1 Qty:6 SEQN:106186 /T4 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19829 KM /WHK 08/21/2018 18'7" 19'11"7 A B C D 4 12 2X4(A1) 4' 4'1' 3"15 1 '7 "1 5 1 '1 1 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 224 / 85 / 131 / -/ 66 / 3.5 D 69 / 6 / 48 / -/ -/ 1.5 C 89 / 54 / 22 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.41 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.002 D - - HORZ(TL):0.004 D - - Creep Factor: 2.0 Max TC CSI:0.240 Max BC CSI:0.158 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ4A Ply: 1 Qty:2 SEQN:106195 /T6 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19719 KM /WHK 08/21/2018 18'7" 19'11"7 A B C D 4 12 2X4(A1) 4' 4'1' 3"15 1 '7 "1 5 1 '1 1 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 224 / 85 / 131 / -/ 66 / 3.5 D 69 / 6 / 48 / -/ -/ 1.5 C 89 / 54 / 22 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.41 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.002 D - - HORZ(TL):0.004 D - - Creep Factor: 2.0 Max TC CSI:0.240 Max BC CSI:0.158 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:CJ4A Ply: 1 Qty:2 SEQN:106195 /T6 /JACK FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19719 KM /WHK 08/21/2018 18'7" 19'11"7 A B C D 4 12 2X4(A1) 4' 4'1' 3"15 1 '7 "1 5 1 '1 1 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 295 / 109 / 169 / -/ 93 / 5.5 D 106 / 10 / 74 / -/ -/ 1.5 C 142 / 87 / 35 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.009 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.554 Max BC CSI:0.363 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:EJ6 Ply: 1 Qty:13 SEQN:106189 /T13 /EJAC FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19594 KM /WHK 08/21/2018 18'7" 20'7"7 A B C D 4 12 2X4(A1) 6' 6'1' 3"15 2 '3 "1 5 2 '7 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 295 / 109 / 169 / -/ 93 / 5.5 D 106 / 10 / 74 / -/ -/ 1.5 C 142 / 87 / 35 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.009 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.554 Max BC CSI:0.363 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:EJ6 Ply: 1 Qty:13 SEQN:106189 /T13 /EJAC FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19594 KM /WHK 08/21/2018 18'7" 20'7"7 A B C D 4 12 2X4(A1) 6' 6'1' 3"15 2 '3 "1 5 2 '7 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 295 / 109 / 169 / -/ 93 / 3.5 D 106 / 10 / 74 / -/ -/ 1.5 C 142 / 87 / 35 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.009 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.554 Max BC CSI:0.363 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:EJ6A Ply: 1 Qty:3 SEQN:106192 /T8 /EJAC FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19704 KM /WHK 08/21/2018 18'7" 20'7"7 A B C D 4 12 2X4(A1) 6' 6'1' 3"15 2 '3 "1 5 2 '7 "1 1 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W B 295 / 109 / 169 / -/ 93 / 3.5 D 106 / 10 / 74 / -/ -/ 1.5 C 142 / 87 / 35 / -/ -/ 1.5 Wind reactions based on MWFRS B Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.009 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.554 Max BC CSI:0.363 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:EJ6A Ply: 1 Qty:3 SEQN:106192 /T8 /EJAC FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19704 KM /WHK 08/21/2018 18'7" 20'7"7 A B C D 4 12 2X4(A1) 6' 6'1' 3"15 2 '3 "1 5 2 '7 "1 1 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x6 SP SS Webs 2x4 SP #3 :W1 2x8 SP #2 N: :W 2, W 8 2x4 SP #2 Dense: Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 9.75" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 67 plf at 0.00 to 67 plf at 0.60 TC: From 177 plf at 0.60 to 177 plf at 11.90 BC: From 7 plf at 0.00 to 7 plf at 0.51 BC: From 73 plf at 0.51 to 73 plf at 0.58 BC: From 249 plf at 0.58 to 249 plf at 11.44 BC: From 7 plf at 11.44 to 7 plf at 11.90 TC: 147 lb Conc. Load at 0.00 Purlins The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL J 2476 /-/-/-/-/- K 2416 /-/-/-/-/- J Brg Width = 3.5 Min Req =1.5 K Brg Width = 5.5 Min Req =1.5 Bearings J & K are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -2837 B - C 0 -3647 Chords Tens.Comp. C - D 0 -3647 D - E 0 -2678 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 2991 0 Chords Tens.Comp. H - G 2852 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 0 -1031 A - I 2806 0 I - B 0 -527 B - H 697 0 Webs Tens.Comp. H - D 844 0 D - G 0 -596 G - E 2804 0 E - F 0 -1033 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.107 C 999 360 VERT(CL):0.206 C 694 240 HORZ(LL):0.017 A - - HORZ(TL):0.034 A - - Creep Factor: 2.0 Max TC CSI:0.503 Max BC CSI:0.493 Max W eb CSI:0.713 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FG1 Ply: 2 Qty:1 SEQN:896610 /T14 /FLAT FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.20016 /BAF 08/21/2018 2 Complete Trusses Required W1 W2 W8 9'1"2 A B C D E FGHIJK 4X10 3X4 3X10 3X4 2X4 3X8 3X4 3X10 3X10 2X4 3"8 11'7"4 3'5"2 3'5"2 6'1"4 2'8"2 8'9"6 2'8"2 11'5"12 2'8"6 11'10"12 5" 3'0"2 3'0"2 6'1"4 3'1"2 9'2"6 3'1"2 11'10"12 2'8"6 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x6 SP SS Webs 2x4 SP #3 :W1 2x8 SP #2 N: :W 2, W 8 2x4 SP #2 Dense: Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 9.75" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 67 plf at 0.00 to 67 plf at 0.60 TC: From 177 plf at 0.60 to 177 plf at 11.90 BC: From 7 plf at 0.00 to 7 plf at 0.51 BC: From 73 plf at 0.51 to 73 plf at 0.58 BC: From 249 plf at 0.58 to 249 plf at 11.44 BC: From 7 plf at 11.44 to 7 plf at 11.90 TC: 147 lb Conc. Load at 0.00 Purlins The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL J 2476 /-/-/-/-/- K 2416 /-/-/-/-/- J Brg Width = 3.5 Min Req =1.5 K Brg Width = 5.5 Min Req =1.5 Bearings J & K are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -2837 B - C 0 -3647 Chords Tens.Comp. C - D 0 -3647 D - E 0 -2678 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 2991 0 Chords Tens.Comp. H - G 2852 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 0 -1031 A - I 2806 0 I - B 0 -527 B - H 697 0 Webs Tens.Comp. H - D 844 0 D - G 0 -596 G - E 2804 0 E - F 0 -1033 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.107 C 999 360 VERT(CL):0.206 C 694 240 HORZ(LL):0.017 A - - HORZ(TL):0.034 A - - Creep Factor: 2.0 Max TC CSI:0.503 Max BC CSI:0.493 Max W eb CSI:0.713 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FG1 Ply: 2 Qty:1 SEQN:896610 /T14 /FLAT FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.20016 /BAF 08/21/2018 2 Complete Trusses Required W1 W2 W8 9'1"2 A B C D E FGHIJK 4X10 3X4 3X10 3X4 2X4 3X8 3X4 3X10 3X10 2X4 3"8 11'7"4 3'5"2 3'5"2 6'1"4 2'8"2 8'9"6 2'8"2 11'5"12 2'8"6 11'10"12 5" 3'0"2 3'0"2 6'1"4 3'1"2 9'2"6 3'1"2 11'10"12 2'8"6 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x6 SP #2 Webs 2x4 SP #3 Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @ 7.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 342 plf at 0.00 to 342 plf at 3.85 BC: From 7 plf at 0.00 to 7 plf at 3.85 Purlins The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 671 /-/-/-/-/- D 671 /-/-/-/-/- E Brg Width = 2.7 Min Req =1.5 D Brg Width = 4.8 Min Req =1.5 Bearings E & D are a rigid surface. Members not listed have forces less than 375# Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. E - D 385 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - B 0 -426 Webs Tens.Comp. B - D 0 -426 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.004 B 999 360 VERT(CL):0.005 B 999 240 HORZ(LL):0.001 D - - HORZ(TL):0.002 D - - Creep Factor: 2.0 Max TC CSI:0.163 Max BC CSI:0.087 Max W eb CSI:0.102 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FG2 Ply: 2 Qty:1 SEQN:896612 /T33 /FLAT FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.20030 /BAF 08/21/2018 2 Complete Trusses Required 9'1"2 A B C DE 2X4 3X4 3X4 2X4 3X4 3'10"4 1'11"2 1'11"2 3'10"4 1'11"2 3'10"4 3'10"4 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x6 SP #2 Webs 2x4 SP #3 Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @ 7.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 342 plf at 0.00 to 342 plf at 3.85 BC: From 7 plf at 0.00 to 7 plf at 3.85 Purlins The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E 671 /-/-/-/-/- D 671 /-/-/-/-/- E Brg Width = 2.7 Min Req =1.5 D Brg Width = 4.8 Min Req =1.5 Bearings E & D are a rigid surface. Members not listed have forces less than 375# Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. E - D 385 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - B 0 -426 Webs Tens.Comp. B - D 0 -426 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.004 B 999 360 VERT(CL):0.005 B 999 240 HORZ(LL):0.001 D - - HORZ(TL):0.002 D - - Creep Factor: 2.0 Max TC CSI:0.163 Max BC CSI:0.087 Max W eb CSI:0.102 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FG2 Ply: 2 Qty:1 SEQN:896612 /T33 /FLAT FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.20030 /BAF 08/21/2018 2 Complete Trusses Required 9'1"2 A B C DE 2X4 3X4 3X4 2X4 3X4 3'10"4 1'11"2 1'11"2 3'10"4 1'11"2 3'10"4 3'10"4 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense :B2 4x2 SP #1 Dense: Webs 4x2 SP #2 Dense Plating Notes All plates are 1X3 except as noted. Deflection Max JT VERT DEFL: LL: 0.50" DL: 0.41". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W U 885 / -/ -/ -/ -/ 4.8 N 885 / -/ -/ -/ -/ 4.8 U Min Brg Width Req =1.5 N Min Brg Width Req =1.5 Bearings U & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -2920 C - D 0 -2920 D - E 0 -4260 E - F 0 -4260 F - G 0 -4269 Chords Tens.Comp. G - H 0 -4260 H - I 0 -4260 I - J 0 -2916 J - K 0 -2916 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. U - T 1640 0 T - S 3769 0 S - R 3769 0 R - Q 4271 0 Chords Tens.Comp. Q - P 4269 0 P - O 3772 0 O - N 1639 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. U - B 0 -1823 B - T 1415 0 T - D 0 -938 D - R 543 0 R - F 337 -393 Webs Tens.Comp. P - I 710 0 I - O 0 -946 O - K 1412 0 K - N 0 -1821 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.498 F 574 360 VERT(TL):0.874 F 417 240 HORZ(LL):0.070 B - - HORZ(TL):0.096 B - - Creep Factor: 2.0 Max TC CSI:0.687 Max BC CSI:0.970 Max W eb CSI:0.359 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT1 Ply: 1 Qty:16 SEQN:106291 /T1 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19689 KM /WHK 08/21/2018 B2 ++ 9'1"2 A B C D E F G H I J K L NOPQRSTU 3X8 3X10 3X10 3X6 W=H0312 3X6 3X4 3X4 W=3X43X6 3X10 3X10 3X8 3"8 24'4"8 3"2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 3" 13'1"8 13'1"8 13'10"8 9" 24'4"8 10'6" 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense :B2 4x2 SP #1 Dense: Webs 4x2 SP #2 Dense Plating Notes All plates are 1X3 except as noted. Deflection Max JT VERT DEFL: LL: 0.50" DL: 0.41". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W U 885 / -/ -/ -/ -/ 4.8 N 885 / -/ -/ -/ -/ 4.8 U Min Brg Width Req =1.5 N Min Brg Width Req =1.5 Bearings U & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -2920 C - D 0 -2920 D - E 0 -4260 E - F 0 -4260 F - G 0 -4269 Chords Tens.Comp. G - H 0 -4260 H - I 0 -4260 I - J 0 -2916 J - K 0 -2916 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. U - T 1640 0 T - S 3769 0 S - R 3769 0 R - Q 4271 0 Chords Tens.Comp. Q - P 4269 0 P - O 3772 0 O - N 1639 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. U - B 0 -1823 B - T 1415 0 T - D 0 -938 D - R 543 0 R - F 337 -393 Webs Tens.Comp. P - I 710 0 I - O 0 -946 O - K 1412 0 K - N 0 -1821 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.498 F 574 360 VERT(TL):0.874 F 417 240 HORZ(LL):0.070 B - - HORZ(TL):0.096 B - - Creep Factor: 2.0 Max TC CSI:0.687 Max BC CSI:0.970 Max W eb CSI:0.359 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT1 Ply: 1 Qty:16 SEQN:106291 /T1 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19689 KM /WHK 08/21/2018 B2 ++ 9'1"2 A B C D E F G H I J K L NOPQRSTU 3X8 3X10 3X10 3X6 W=H0312 3X6 3X4 3X4 W=3X43X6 3X10 3X10 3X8 3"8 24'4"8 3"2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 3" 13'1"8 13'1"8 13'10"8 9" 24'4"8 10'6" 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #2 Dense Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1X3 except as noted. Additional Notes Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W V*73 / -/ -/ -/ -/ 292 V Min Brg Width Req =- Bearing AO is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.000 S 999 360 VERT(TL):0.000 S 999 240 HORZ(LL):0.000 T - - HORZ(TL):0.000 T - - Creep Factor: 2.0 Max TC CSI:0.069 Max BC CSI:0.014 Max W eb CSI:0.013 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT1GE Ply: 1 Qty:1 SEQN:106296 /T10 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19688 KM /WHK 08/21/2018 9'1"2 A K M T V WACAEAHANAO 3X4 2X4 3X4 W=3X4 3X4 3X4 3X4 W=3X4 3X4 3X4 2X4 3"8 24'4"8 1'4"12 1'4" (TYP) 1'5"8 1'5"8 24'4"8 22'11" 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #2 Dense Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1X3 except as noted. Additional Notes Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W V*73 / -/ -/ -/ -/ 292 V Min Brg Width Req =- Bearing AO is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.000 S 999 360 VERT(TL):0.000 S 999 240 HORZ(LL):0.000 T - - HORZ(TL):0.000 T - - Creep Factor: 2.0 Max TC CSI:0.069 Max BC CSI:0.014 Max W eb CSI:0.013 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT1GE Ply: 1 Qty:1 SEQN:106296 /T10 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19688 KM /WHK 08/21/2018 9'1"2 A K M T V WACAEAHANAO 3X4 2X4 3X4 W=3X4 3X4 3X4 3X4 W=3X4 3X4 3X4 2X4 3"8 24'4"8 1'4"12 1'4" (TYP) 1'5"8 1'5"8 24'4"8 22'11" 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 24.25 BC: From 10 plf at 0.00 to 10 plf at 24.37 TC: 975 lb Conc. Load at 0.00 TC: 220 lb Conc. Load at 0.13 Plating Notes All plates are 3X6 except as noted. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W U 1878 / -/ -/ -/ -/ - Q 1441 / -/ -/ -/ -/ 3.5 N 619 / -/ -/ -/ -/ 4.8 U Min Brg Width Req =- Q Min Brg Width Req =1.5 N Min Brg Width Req =1.5 Bearings Q & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1363 C - D 0 -1373 D - E 0 -1360 E - F 880 0 F - G 880 0 Chords Tens.Comp. G - H 880 0 H - I 0 -1374 I - J 0 -1385 J - K 0 -1377 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. U - T 877 0 T - S 1373 0 S - R 741 -58 R - Q 741 -58 Chords Tens.Comp. Q - P 864 -126 P - O 1385 0 O - N 1000 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - U 0 -1343 U - B 0 -1227 B - T 539 0 S - E 790 0 E - Q 0 -1337 Webs Tens.Comp. Q - H 0 -1330 H - P 779 0 O - K 456 0 K - N 0 -1112 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.092 C 999 360 VERT(TL):0.233 C 929 240 HORZ(LL):0.019 B - - HORZ(TL):0.033 B - - Creep Factor: 2.0 Max TC CSI:0.770 Max BC CSI:0.602 Max W eb CSI:0.376 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT2 Ply: 1 Qty:3 SEQN:891206 /T30 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19845 KM /DF 08/21/2018 ++ 9'1"2 A B C D E F G H I J K L NOPQRSTU 2X4 3X4 1X3 1X3 3X4 W=3X4 W=3X41X3 3X8 3X4 1X3 1X3 3X4 1X31X3 3"8 12'7"8 11'9" 3"2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 3" 24'4"8 5'4"8 5'4"8 7'5"4 2'0"12 17'9"12 10'4"8 19' 1'2"4 24'4"8 5'4"8 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 24.25 BC: From 10 plf at 0.00 to 10 plf at 24.37 TC: 975 lb Conc. Load at 0.00 TC: 220 lb Conc. Load at 0.13 Plating Notes All plates are 3X6 except as noted. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W U 1878 / -/ -/ -/ -/ - Q 1441 / -/ -/ -/ -/ 3.5 N 619 / -/ -/ -/ -/ 4.8 U Min Brg Width Req =- Q Min Brg Width Req =1.5 N Min Brg Width Req =1.5 Bearings Q & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1363 C - D 0 -1373 D - E 0 -1360 E - F 880 0 F - G 880 0 Chords Tens.Comp. G - H 880 0 H - I 0 -1374 I - J 0 -1385 J - K 0 -1377 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. U - T 877 0 T - S 1373 0 S - R 741 -58 R - Q 741 -58 Chords Tens.Comp. Q - P 864 -126 P - O 1385 0 O - N 1000 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - U 0 -1343 U - B 0 -1227 B - T 539 0 S - E 790 0 E - Q 0 -1337 Webs Tens.Comp. Q - H 0 -1330 H - P 779 0 O - K 456 0 K - N 0 -1112 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.092 C 999 360 VERT(TL):0.233 C 929 240 HORZ(LL):0.019 B - - HORZ(TL):0.033 B - - Creep Factor: 2.0 Max TC CSI:0.770 Max BC CSI:0.602 Max W eb CSI:0.376 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT2 Ply: 1 Qty:3 SEQN:891206 /T30 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19845 KM /DF 08/21/2018 ++ 9'1"2 A B C D E F G H I J K L NOPQRSTU 2X4 3X4 1X3 1X3 3X4 W=3X4 W=3X41X3 3X8 3X4 1X3 1X3 3X4 1X31X3 3"8 12'7"8 11'9" 3"2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 2'6"12 3" 24'4"8 5'4"8 5'4"8 7'5"4 2'0"12 17'9"12 10'4"8 19' 1'2"4 24'4"8 5'4"8 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 24.25 BC: From 10 plf at 0.00 to 10 plf at 24.37 TC: 1195 lb Conc. Load at 0.00 Plating Notes All plates are 3X4 except as noted. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W U 1869 / -/ -/ -/ -/ - N*168 / -/ -/ -/ -/ 142 P / 122 U Min Brg Width Req =- N Min Brg Width Req =- Bearing Q is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1294 C - D 0 -1304 D - E 0 -1290 Chords Tens.Comp. E - F 561 0 F - G 561 0 G - H 561 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. U - T 836 0 T - S 1304 0 Chords Tens.Comp. S - R 645 0 R - Q 645 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - U 0 -1345 U - B 0 -1206 B - T 509 0 S - E 721 0 Webs Tens.Comp. E - Q 0 -1319 P - I 0 -409 O - K 0 -405 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.077 C 999 360 VERT(TL):0.177 C 999 240 HORZ(LL):0.014 B - - HORZ(TL):0.022 B - - Creep Factor: 2.0 Max TC CSI:0.550 Max BC CSI:0.475 Max W eb CSI:0.365 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT2A Ply: 1 Qty:1 SEQN:891204 /T31 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19953 KM /DF 08/21/2018 9'1"2 A B C D E F G H I J K L N OP QRSTU 2X4 3X6 3X6 1X3 1X3 3X6 W=3X4 W=3X41X3 3X8 1X3 3X6 1X3 3X6 1X3 3"8 24'4"8 3"2'6"12 2'6"12 2'6"12 1'3" 2'6"12 2'6"12 3" 5'4"8 5'4"8 7'5"4 2'0"12 24'4"8 16'11"4 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 24.25 BC: From 10 plf at 0.00 to 10 plf at 24.37 TC: 1195 lb Conc. Load at 0.00 Plating Notes All plates are 3X4 except as noted. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W U 1869 / -/ -/ -/ -/ - N*168 / -/ -/ -/ -/ 142 P / 122 U Min Brg Width Req =- N Min Brg Width Req =- Bearing Q is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1294 C - D 0 -1304 D - E 0 -1290 Chords Tens.Comp. E - F 561 0 F - G 561 0 G - H 561 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. U - T 836 0 T - S 1304 0 Chords Tens.Comp. S - R 645 0 R - Q 645 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - U 0 -1345 U - B 0 -1206 B - T 509 0 S - E 721 0 Webs Tens.Comp. E - Q 0 -1319 P - I 0 -409 O - K 0 -405 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.077 C 999 360 VERT(TL):0.177 C 999 240 HORZ(LL):0.014 B - - HORZ(TL):0.022 B - - Creep Factor: 2.0 Max TC CSI:0.550 Max BC CSI:0.475 Max W eb CSI:0.365 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT2A Ply: 1 Qty:1 SEQN:891204 /T31 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19953 KM /DF 08/21/2018 9'1"2 A B C D E F G H I J K L N OP QRSTU 2X4 3X6 3X6 1X3 1X3 3X6 W=3X4 W=3X41X3 3X8 1X3 3X6 1X3 3X6 1X3 3"8 24'4"8 3"2'6"12 2'6"12 2'6"12 1'3" 2'6"12 2'6"12 3" 5'4"8 5'4"8 7'5"4 2'0"12 24'4"8 16'11"4 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #2 Dense Deflection Max JT VERT DEFL: LL: 0.21" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W Q 934 / -/ -/ -/ -/ 4.8 K 932 / -/ -/ -/ -/ 2.7 Q Min Brg Width Req =1.5 K Min Brg Width Req =1.5 Bearings Q & K are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -2735 C - D 0 -2735 D - E 0 -3169 Chords Tens.Comp. E - F 0 -2741 F - G 0 -2741 G - H 0 -2741 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1645 0 P - O 1645 0 O - N 3168 0 Chords Tens.Comp. N - M 3169 0 M - L 3169 0 L - K 1656 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. Q - B 0 -1829 B - O 1204 0 O - D 0 -688 Webs Tens.Comp. E - L 0 -683 L - H 1199 0 H - K 0 -1836 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.210 M 953 360 VERT(TL):0.369 M 692 240 HORZ(LL):0.039 K - - HORZ(TL):0.054 K - - Creep Factor: 2.0 Max TC CSI:0.549 Max BC CSI:0.917 Max W eb CSI:0.330 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT3 Ply: 1 Qty:2 SEQN:106299 /T21 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19690 KM /WHK 08/21/2018 +9'1"2 A B C D E F G H I KLMNOPQ 1X31X3 3X8 3X10 W=3X4 1X3 3X10 3X4 1X3 1X3 3X4 1X3 3X10 W=3X43X10 1X3 3X8 1X3 3"8 17'2"4 3"2'6"12 2'6"12 2'6"12 2'6"12 3" 8' 8' 9'2"4 1'2"4 17'2"4 8' 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #2 Dense Deflection Max JT VERT DEFL: LL: 0.21" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W Q 934 / -/ -/ -/ -/ 4.8 K 932 / -/ -/ -/ -/ 2.7 Q Min Brg Width Req =1.5 K Min Brg Width Req =1.5 Bearings Q & K are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -2735 C - D 0 -2735 D - E 0 -3169 Chords Tens.Comp. E - F 0 -2741 F - G 0 -2741 G - H 0 -2741 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1645 0 P - O 1645 0 O - N 3168 0 Chords Tens.Comp. N - M 3169 0 M - L 3169 0 L - K 1656 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. Q - B 0 -1829 B - O 1204 0 O - D 0 -688 Webs Tens.Comp. E - L 0 -683 L - H 1199 0 H - K 0 -1836 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.210 M 953 360 VERT(TL):0.369 M 692 240 HORZ(LL):0.039 K - - HORZ(TL):0.054 K - - Creep Factor: 2.0 Max TC CSI:0.549 Max BC CSI:0.917 Max W eb CSI:0.330 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT3 Ply: 1 Qty:2 SEQN:106299 /T21 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19690 KM /WHK 08/21/2018 +9'1"2 A B C D E F G H I KLMNOPQ 1X31X3 3X8 3X10 W=3X4 1X3 3X10 3X4 1X3 1X3 3X4 1X3 3X10 W=3X43X10 1X3 3X8 1X3 3"8 17'2"4 3"2'6"12 2'6"12 2'6"12 2'6"12 3" 8' 8' 9'2"4 1'2"4 17'2"4 8' 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense :B2 4x2 SP #1 Dense: Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 17.06 BC: From 10 plf at 0.00 to 10 plf at 17.19 TC: 975 lb Conc. Load at 0.00 TC: 220 lb Conc. Load at 0.25 Deflection Max JT VERT DEFL: LL: 0.18" DL: 0.30". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W Q 2156 / -/ -/ -/ -/ - K 917 / -/ -/ -/ -/ 2.7 Q Min Brg Width Req =- K Min Brg Width Req =1.5 Bearing K is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -2590 C - D 0 -2590 D - E 0 -3067 Chords Tens.Comp. E - F 0 -2679 F - G 0 -2679 G - H 0 -2679 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1472 0 P - O 3066 0 O - N 3066 0 Chords Tens.Comp. N - M 3067 0 M - L 3067 0 L - K 1625 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Q 0 -1345 Q - B 0 -1863 B - P 1236 0 P - D 0 -707 Webs Tens.Comp. E - L 0 -638 L - H 1165 0 H - K 0 -1801 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.179 M 999 360 VERT(TL):0.403 M 688 240 HORZ(LL):0.029 K - - HORZ(TL):0.048 K - - Creep Factor: 2.0 Max TC CSI:0.638 Max BC CSI:0.877 Max W eb CSI:0.589 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT3 Ply: 1 Qty:4 SEQN:891208 /T32 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19985 KM /DF 08/21/2018 B2+9'1"2 A B C D E F G H I KLMNOPQ 2X4 3X8 3X10 1X3 3X10 W=SS0312 3X4 1X3 1X3 3X4W=3X4 1X3 3X8 3X10 1X3 3X8 1X3 3"8 17'2"4 3"2'6"12 2'6"12 2'6"12 2'6"12 3" 8' 8' 9'2"4 1'2"4 17'2"4 8' 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense :B2 4x2 SP #1 Dense: Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 17.06 BC: From 10 plf at 0.00 to 10 plf at 17.19 TC: 975 lb Conc. Load at 0.00 TC: 220 lb Conc. Load at 0.25 Deflection Max JT VERT DEFL: LL: 0.18" DL: 0.30". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W Q 2156 / -/ -/ -/ -/ - K 917 / -/ -/ -/ -/ 2.7 Q Min Brg Width Req =- K Min Brg Width Req =1.5 Bearing K is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -2590 C - D 0 -2590 D - E 0 -3067 Chords Tens.Comp. E - F 0 -2679 F - G 0 -2679 G - H 0 -2679 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1472 0 P - O 3066 0 O - N 3066 0 Chords Tens.Comp. N - M 3067 0 M - L 3067 0 L - K 1625 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Q 0 -1345 Q - B 0 -1863 B - P 1236 0 P - D 0 -707 Webs Tens.Comp. E - L 0 -638 L - H 1165 0 H - K 0 -1801 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.179 M 999 360 VERT(TL):0.403 M 688 240 HORZ(LL):0.029 K - - HORZ(TL):0.048 K - - Creep Factor: 2.0 Max TC CSI:0.638 Max BC CSI:0.877 Max W eb CSI:0.589 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT3 Ply: 1 Qty:4 SEQN:891208 /T32 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19985 KM /DF 08/21/2018 B2+9'1"2 A B C D E F G H I KLMNOPQ 2X4 3X8 3X10 1X3 3X10 W=SS0312 3X4 1X3 1X3 3X4W=3X4 1X3 3X8 3X10 1X3 3X8 1X3 3"8 17'2"4 3"2'6"12 2'6"12 2'6"12 2'6"12 3" 8' 8' 9'2"4 1'2"4 17'2"4 8' 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 12.75 BC: From 10 plf at 0.00 to 10 plf at 12.87 TC: 220 lb Conc. Load at 0.00 TC: 224 lb Conc. Load at 0.13 Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W K 1159 / -/ -/ -/ -/ - H 689 / -/ -/ -/ -/ 4.8 K Min Brg Width Req =- H Min Brg Width Req =1.5 Bearing H is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1679 C - D 0 -1691 Chords Tens.Comp. D - E 0 -1679 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1099 0 J - I 1691 0 Chords Tens.Comp. I - H 1140 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - K 0 -579 K - B 0 -1300 B - J 717 0 Webs Tens.Comp. I - E 676 0 E - H 0 -1267 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.081 C 999 360 VERT(TL):0.266 D 863 240 HORZ(LL):0.017 B - - HORZ(TL):0.034 B - - Creep Factor: 2.0 Max TC CSI:0.737 Max BC CSI:0.709 Max W eb CSI:0.360 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT4 Ply: 1 Qty:2 SEQN:891200 /T29 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19875 KM /DF 08/21/2018 + 9'1"2 A B C D E F HIJK 2X4 3X6 3X6 3X4 1X3 1X3 3X4 3X6 1X3 3X6 1X3 3"8 12'10"8 3"2'6"12 2'6"12 3" 5'4"8 5'4"8 7'6" 2'1"8 12'10"8 5'4"8 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 12.75 BC: From 10 plf at 0.00 to 10 plf at 12.87 TC: 220 lb Conc. Load at 0.00 TC: 224 lb Conc. Load at 0.13 Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W K 1159 / -/ -/ -/ -/ - H 689 / -/ -/ -/ -/ 4.8 K Min Brg Width Req =- H Min Brg Width Req =1.5 Bearing H is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1679 C - D 0 -1691 Chords Tens.Comp. D - E 0 -1679 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1099 0 J - I 1691 0 Chords Tens.Comp. I - H 1140 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - K 0 -579 K - B 0 -1300 B - J 717 0 Webs Tens.Comp. I - E 676 0 E - H 0 -1267 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.081 C 999 360 VERT(TL):0.266 D 863 240 HORZ(LL):0.017 B - - HORZ(TL):0.034 B - - Creep Factor: 2.0 Max TC CSI:0.737 Max BC CSI:0.709 Max W eb CSI:0.360 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT4 Ply: 1 Qty:2 SEQN:891200 /T29 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19875 KM /DF 08/21/2018 + 9'1"2 A B C D E F HIJK 2X4 3X6 3X6 3X4 1X3 1X3 3X4 3X6 1X3 3X6 1X3 3"8 12'10"8 3"2'6"12 2'6"12 3" 5'4"8 5'4"8 7'6" 2'1"8 12'10"8 5'4"8 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 12.75 BC: From 10 plf at 0.00 to 10 plf at 12.87 TC: 220 lb Conc. Load at 0.00 TC: 704 lb Conc. Load at 0.13 Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W K 1644 / -/ -/ -/ -/ - H 684 / -/ -/ -/ -/ 4.8 K Min Brg Width Req =- H Min Brg Width Req =1.5 Bearing H is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1654 C - D 0 -1666 Chords Tens.Comp. D - E 0 -1655 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1059 0 J - I 1666 0 Chords Tens.Comp. I - H 1130 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - K 0 -1064 K - B 0 -1311 B - J 724 0 Webs Tens.Comp. I - E 660 0 E - H 0 -1256 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.080 C 999 360 VERT(TL):0.279 D 856 240 HORZ(LL):0.017 B - - HORZ(TL):0.032 B - - Creep Factor: 2.0 Max TC CSI:0.752 Max BC CSI:0.713 Max W eb CSI:0.363 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT4B Ply: 1 Qty:1 SEQN:891202 /T12 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19874 KM /DF 08/21/2018 + 9'1"2 A B C D E F HIJK 2X4 3X6 3X6 3X4 1X3 1X3 3X4 3X6 1X3 3X6 1X3 3"8 12'10"8 3"2'6"12 2'6"12 3" 5'4"8 5'4"8 7'6" 2'1"8 12'10"8 5'4"8 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 12.75 BC: From 10 plf at 0.00 to 10 plf at 12.87 TC: 220 lb Conc. Load at 0.00 TC: 704 lb Conc. Load at 0.13 Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W K 1644 / -/ -/ -/ -/ - H 684 / -/ -/ -/ -/ 4.8 K Min Brg Width Req =- H Min Brg Width Req =1.5 Bearing H is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1654 C - D 0 -1666 Chords Tens.Comp. D - E 0 -1655 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1059 0 J - I 1666 0 Chords Tens.Comp. I - H 1130 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - K 0 -1064 K - B 0 -1311 B - J 724 0 Webs Tens.Comp. I - E 660 0 E - H 0 -1256 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.080 C 999 360 VERT(TL):0.279 D 856 240 HORZ(LL):0.017 B - - HORZ(TL):0.032 B - - Creep Factor: 2.0 Max TC CSI:0.752 Max BC CSI:0.713 Max W eb CSI:0.363 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT4B Ply: 1 Qty:1 SEQN:891202 /T12 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19874 KM /DF 08/21/2018 + 9'1"2 A B C D E F HIJK 2X4 3X6 3X6 3X4 1X3 1X3 3X4 3X6 1X3 3X6 1X3 3"8 12'10"8 3"2'6"12 2'6"12 3" 5'4"8 5'4"8 7'6" 2'1"8 12'10"8 5'4"8 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #2 Dense Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1X3 except as noted. Additional Notes Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W M*108 / -/ -/ -/ -/ 154 M Min Brg Width Req =- Bearing W is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.000 D 999 360 VERT(TL):0.000 D 999 240 HORZ(LL):0.000 K - - HORZ(TL):0.000 K - - Creep Factor: 2.0 Max TC CSI:0.074 Max BC CSI:0.018 Max W eb CSI:0.018 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT4GE Ply: 1 Qty:1 SEQN:106308 /T15 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19532 KM /WHK 08/21/2018 9'1"2 A E G K M NRV W 3X4 2X4 3X4 3X4 3X4 3X4 3X4 3X4 2X4 3"8 12'10"8 11"12 1'4" (TYP) 3"4'9"8 2'6"8 4'9"8 3" 1'0"8 1'0"8 12'10"8 11'10" 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #2 Dense Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1X3 except as noted. Additional Notes Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Loc R / U / Rw / Rh / RL / W M*108 / -/ -/ -/ -/ 154 M Min Brg Width Req =- Bearing W is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.000 D 999 360 VERT(TL):0.000 D 999 240 HORZ(LL):0.000 K - - HORZ(TL):0.000 K - - Creep Factor: 2.0 Max TC CSI:0.074 Max BC CSI:0.018 Max W eb CSI:0.018 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT4GE Ply: 1 Qty:1 SEQN:106308 /T15 /SY42 FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19532 KM /WHK 08/21/2018 9'1"2 A E G K M NRV W 3X4 2X4 3X4 3X4 3X4 3X4 3X4 3X4 2X4 3"8 12'10"8 11"12 1'4" (TYP) 3"4'9"8 2'6"8 4'9"8 3" 1'0"8 1'0"8 12'10"8 11'10" 1 '4 " 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense Bot chord 2x4 SP #2 Dense Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 plf at -1.41 to 54 plf at 0.00 TC: From 2 plf at 0.00 to 2 plf at 8.42 BC: From 0 plf at -1.41 to 4 plf at 0.00 BC: From 2 plf at 0.00 to 2 plf at 8.42 TC: 64 lb Conc. Load at 2.83 TC: 179 lb Conc. Load at 5.66 BC: 60 lb Conc. Load at 2.83 BC: 137 lb Conc. Load at 5.66 Wind Wind loads and reactions based on MWFRS. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W E 262 / 84 / -/ -/ -/ 7.0 D 147 / 12 / -/ -/ -/ 1.5 C 144 / 64 / -/ -/ -/ 1.5 Wind reactions based on MWFRS E Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing E is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.022 D - - HORZ(TL):0.043 D - - Creep Factor: 2.0 Max TC CSI:0.768 Max BC CSI:0.844 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:HJ6 Ply: 1 Qty:3 SEQN:106177 /T19 /HIP_ FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19533 KM /WHK 08/21/2018 18'7" 20'7"4 A B C DE 2.83 12 2X4(A1) 8'5"1 8'5"11'5" 3"15 2 '3 "1 2 2 '7 "7 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense Bot chord 2x4 SP #2 Dense Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 plf at -1.41 to 54 plf at 0.00 TC: From 2 plf at 0.00 to 2 plf at 8.42 BC: From 0 plf at -1.41 to 4 plf at 0.00 BC: From 2 plf at 0.00 to 2 plf at 8.42 TC: 64 lb Conc. Load at 2.83 TC: 179 lb Conc. Load at 5.66 BC: 60 lb Conc. Load at 2.83 BC: 137 lb Conc. Load at 5.66 Wind Wind loads and reactions based on MWFRS. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W E 262 / 84 / -/ -/ -/ 7.0 D 147 / 12 / -/ -/ -/ 1.5 C 144 / 64 / -/ -/ -/ 1.5 Wind reactions based on MWFRS E Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing E is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.022 D - - HORZ(TL):0.043 D - - Creep Factor: 2.0 Max TC CSI:0.768 Max BC CSI:0.844 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:HJ6 Ply: 1 Qty:3 SEQN:106177 /T19 /HIP_ FROM: MT Cust: R R408 JRef:1WdP4080027 DrwNo:233.18.1627.19533 KM /WHK 08/21/2018 18'7" 20'7"4 A B C DE 2.83 12 2X4(A1) 8'5"1 8'5"11'5" 3"15 2 '3 "1 2 2 '7 "7 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense Bot chord 2x4 SP #2 Dense Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 plf at -1.41 to 54 plf at 0.00 TC: From 2 plf at 0.00 to 2 plf at 8.42 BC: From 0 plf at -1.41 to 4 plf at 0.00 BC: From 2 plf at 0.00 to 2 plf at 8.42 TC: 64 lb Conc. Load at 2.83 TC: 179 lb Conc. Load at 5.66 BC: 60 lb Conc. Load at 2.83 BC: 137 lb Conc. Load at 5.66 Wind Wind loads and reactions based on MWFRS. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W E 262 / 84 / -/ -/ -/ 4.2 D 147 / 12 / -/ -/ -/ 1.5 C 144 / 64 / -/ -/ -/ 1.5 Wind reactions based on MWFRS E Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing E is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.022 D - - HORZ(TL):0.043 D - - Creep Factor: 2.0 Max TC CSI:0.768 Max BC CSI:0.844 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:HJ6A Ply: 1 Qty:1 SEQN:106373 /T9 HIP_ FROM: MT Cust: R 408 JRef:1WdP4080027 DrwNo:233.18.1627.19828 KM /WHK 08/21/2018 18'7" 20'7"4 A B C DE 2.83 12 2X4(A1) 8'5"1 8'5"11'5" 3"15 2 '3 "1 2 2 '7 "7 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 2x4 SP #1 Dense Bot chord 2x4 SP #2 Dense Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 0 plf at -1.41 to 54 plf at 0.00 TC: From 2 plf at 0.00 to 2 plf at 8.42 BC: From 0 plf at -1.41 to 4 plf at 0.00 BC: From 2 plf at 0.00 to 2 plf at 8.42 TC: 64 lb Conc. Load at 2.83 TC: 179 lb Conc. Load at 5.66 BC: 60 lb Conc. Load at 2.83 BC: 137 lb Conc. Load at 5.66 Wind Wind loads and reactions based on MWFRS. Additional Notes Provide (2) 16d common(0.162"x3.5") toe-nails at top chord. Provide (2) 16d common(0.162"x3.5") toe-nails at bottom chord. Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W E 262 / 84 / -/ -/ -/ 4.2 D 147 / 12 / -/ -/ -/ 1.5 C 144 / 64 / -/ -/ -/ 1.5 Wind reactions based on MWFRS E Min Brg Width Req =1.5 D Min Brg Width Req =- C Min Brg Width Req =- Bearing E is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-10 Speed:140 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 19.74 ft TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(TL):NA HORZ(LL):0.022 D - - HORZ(TL):0.043 D - - Creep Factor: 2.0 Max TC CSI:0.768 Max BC CSI:0.844 Max W eb CSI:0.000 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:HJ6A Ply: 1 Qty:1 SEQN:106373 /T9 HIP_ FROM: MT Cust: R 408 JRef:1WdP4080027 DrwNo:233.18.1627.19828 KM /WHK 08/21/2018 18'7" 20'7"4 A B C DE 2.83 12 2X4(A1) 8'5"1 8'5"11'5" 3"15 2 '3 "1 2 2 '7 "7 08/22/2018 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Additional Notes Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL I 404 /-/-/-/-/- F 393 /-/-/-/-/- I Brg Width = 2.8 Min Req =1.5 F Brg Width = 4.8 Min Req =1.5 Bearings I & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -538 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 537 0 H - G 538 0 Chords Tens.Comp. G - F 537 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. I - B 0 -596 Webs Tens.Comp. C - F 0 -597 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.025 H 999 360 VERT(CL):0.041 H 999 240 HORZ(LL):0.009 B - - HORZ(TL):0.014 B - - Creep Factor: 2.0 Max TC CSI:0.390 Max BC CSI:0.296 Max W eb CSI:0.165 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT6 Ply: 1 Qty:1 SEQN:896856 /T24 SY42 FROM: MT Cust: R 408 JRef:1WdP4080027 DrwNo:234.18.0815.21983 KD /WHK 08/22/2018 9'1"2 A B C D FGHI 3X6 2X4 3X4 1X3 1X3 3X4 1X3 3X6 1X3 4" 7'4"4 3"2'6" (TYP) 3" 2'10"8 2'10"8 4'5"12 1'7"4 7'4"4 2'10"8 1 '4 " **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord 4x2 SP #2 Dense Bot chord 4x2 SP #2 Dense Webs 4x2 SP #3 Additional Notes Deflection estimate assumes composite action with single layer of the appropriate span rated glue-nailed wood sheathing. Webs are square cut except dbl diagonals or as otherwise shown. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL I 404 /-/-/-/-/- F 393 /-/-/-/-/- I Brg Width = 2.8 Min Req =1.5 F Brg Width = 4.8 Min Req =1.5 Bearings I & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -538 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 537 0 H - G 538 0 Chords Tens.Comp. G - F 537 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. I - B 0 -596 Webs Tens.Comp. C - F 0 -597 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MW FRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code:FBC 2017 RES TPI Std:2014 Rep Factors Used: Yes FT/RT:0(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.025 H 999 360 VERT(CL):0.041 H 999 240 HORZ(LL):0.009 B - - HORZ(TL):0.014 B - - Creep Factor: 2.0 Max TC CSI:0.390 Max BC CSI:0.296 Max W eb CSI:0.165 VIEW Ver: 17.02.01A.1114.21 Job Number:21190 MODEL 1891A /MODEL 1891A -Pinnacle Homes Truss Label:FT6 Ply: 1 Qty:1 SEQN:896856 /T24 SY42 FROM: MT Cust: R 408 JRef:1WdP4080027 DrwNo:234.18.0815.21983 KD /WHK 08/22/2018 9'1"2 A B C D FGHI 3X6 2X4 3X4 1X3 1X3 3X4 1X3 3X6 1X3 4" 7'4"4 3"2'6" (TYP) 3" 2'10"8 2'10"8 4'5"12 1'7"4 7'4"4 2'10"8 1 '4 " 08/22/2018 COA #0 278 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 08/22/2018COA #0 278 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 08/22/2018COA #0 278 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 08/22/2018COA #0 278 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 08/22/2018COA #0 278 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 08/22/2018COA #0 278 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 08/22/2018COA #0 278