Loading...
49 Dudley St RES20-0172 17 of 17 energy calcs signatures_1FORM 8405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: PINN1891(GR) BuilderName: Pinnacle Homes Corp. Street: 49 Dudley Street Permit Office: City of Atlantic Beach City, State, Zip: Atlantic Beach , FL , PermitNumber Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville County: Duval (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9, Wall Types (2318.8 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame- Wood, Exterior R=13.0 2071.30 ft' b. Frame - Wood, Adjacent R=13.0 247.50 ft' 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft' 10. Ceiling Types (1167.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 1167.00 ft' 6. Conditioned floor area above grade (ft') 1891 b. N/A R= ftz Conditioned floor area below grade (ft') 0 c. NIA R= 11. Ducts R ft' 7. Windows(210.5 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 380.2 a. U -Factor: Dbl, U=0.33 170.50 ftz SHGC: SHGC=0.21 b. U -Factor: Dbl, U=0.32 40,00 ftz 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=O 23 a. Central Unit 36.0 SEER:14.00 c. U -Factor: NIA ftz SHGC: 13. Heating systems kStu)hr Efficiency d. U -Factor. NIA ft' a. Electric Heat Pump 36.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.361 ft. Area Weighted Average SHGC: 0,214 14. Hot water systems a. Electric Cap: 50 gallons ypes (1899.0 s ft. 8. FloorT q ) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 798.DD ftz b. Conservation features b. Floor Over Other Space R=0.0 796.00 ft' None c. other (see details) R= 297.00 ft' 15. Credits Pstat Glass/Floor Area: 0.11 1 Total Proposed Modified Loads: 54.01 PASS Total Baseline Loads: 55.05 �7�7 I hereby certify that the plans and specifications covered by Review of the plans ands S-r4� this calculation are in compliance with the Florida Energy specifications covered by this Code. Digitally signed by Douglas R. Calculation indicates compliance Douglas R. SiIClSIe5 statues with the Florida Energy Code. ,r,,.t = �- ..� ;, �0� PREPARED BY: _ Date: 2020.02.05 11:45:+k8-05'04' Before construction is completed tic __It DATE: _ - this building will be inspected for j Al__ compliance with Section 553.908 a -a I hereby certify that this building, as designed, is in compliance Florida Statutes. rt,S with the Florida EQ=y Code_ --- -- C4D WIE OWNERIAGENT. - BUILDING OFFICIAL. DATE: _ DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). 2/612020 10:44 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page t of 5 2017 EPL DISPLAY CARD 7e� ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location 2nd Floor 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13, Cooling system: Capacity 36.0 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Groundfwater source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1891 d) Room unitJPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.328 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.214 14. Heating system: Capacity 36.0 c) Area 7C. 210.5 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace. LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R -value) 9a. 0.0 b) Wood, raised (R -value) 9b. 19.0 15. Water heating system c) Concrete, raised (R -value) 9c, a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R -value) 10A1. 13.0 e) dedicated heat pump with tank EF 2. Masonry (insulation R -value) 10A2. f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame {Insulation R -value) 10131. 13.0 2. Masonry (Insulation R -value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 38.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: date: Address of New Home: _49 Dudley Street City/FL Zip: Atlantic Beach, FL 21512020 10:45:21 AM EnergyGaugeO USA6.0.04 (Rev. 1) - FlaRes2017 FBG 8th Edition (2417) Compliant Software Page 1 of 1