49 Dudley St RES20-0172 17 of 17 energy calcs signatures_1FORM 8405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: PINN1891(GR)
BuilderName: Pinnacle Homes Corp.
Street: 49 Dudley Street
Permit Office: City of Atlantic Beach
City, State, Zip: Atlantic Beach , FL ,
PermitNumber
Owner:
Jurisdiction: 261100
Design Location: FL,Jacksonville
County: Duval (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9, Wall Types (2318.8 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Frame- Wood, Exterior
R=13.0 2071.30 ft'
b. Frame - Wood, Adjacent
R=13.0 247.50 ft'
3. Number of units, if multiple family
1
c. NIA
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft'
10. Ceiling Types (1167.0 sgft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=38.0 1167.00 ft'
6. Conditioned floor area above grade (ft')
1891
b. N/A
R= ftz
Conditioned floor area below grade (ft')
0
c. NIA
R=
11. Ducts
R ft'
7. Windows(210.5 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: 2nd Floor
6 380.2
a. U -Factor: Dbl, U=0.33
170.50 ftz
SHGC: SHGC=0.21
b. U -Factor: Dbl, U=0.32
40,00 ftz
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=O 23
a. Central Unit
36.0 SEER:14.00
c. U -Factor: NIA
ftz
SHGC:
13. Heating systems
kStu)hr Efficiency
d. U -Factor. NIA
ft'
a. Electric Heat Pump
36.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth:
1.361 ft.
Area Weighted Average SHGC:
0,214
14. Hot water systems
a. Electric
Cap: 50 gallons
ypes (1899.0 s ft.
8. FloorT q )
Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation
R=0.0 798.DD ftz
b. Conservation features
b. Floor Over Other Space
R=0.0 796.00 ft'
None
c. other (see details)
R= 297.00 ft'
15. Credits
Pstat
Glass/Floor Area: 0.11 1
Total Proposed Modified Loads: 54.01
PASS
Total Baseline Loads: 55.05
�7�7
I hereby certify that the plans and specifications covered by
Review of the plans ands
S-r4�
this calculation are in compliance with
the Florida Energy
specifications covered by this
Code.
Digitally signed by Douglas R.
Calculation indicates compliance
Douglas R. SiIClSIe5
statues
with the Florida Energy Code.
,r,,.t = �- ..� ;, �0�
PREPARED BY: _
Date: 2020.02.05 11:45:+k8-05'04'
Before construction is completed
tic
__It
DATE: _ -
this building will be inspected for
j Al__
compliance with Section 553.908
a -a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
rt,S
with the Florida EQ=y Code_ ---
--
C4D WIE
OWNERIAGENT.
-
BUILDING OFFICIAL.
DATE:
_
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
2/612020 10:44 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page t of 5
2017 EPL DISPLAY CARD
7e�
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location 2nd
Floor
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13, Cooling system: Capacity
36.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Groundfwater source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1891
d) Room unitJPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.328
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.214
14. Heating system: Capacity
36.0
c) Area
7C.
210.5
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace. LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R -value)
9a.
0.0
b) Wood, raised (R -value)
9b.
19.0
15. Water heating system
c) Concrete, raised (R -value)
9c,
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R -value)
10A1.
13.0
e) dedicated heat pump with tank EF
2. Masonry (insulation R -value)
10A2.
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame {Insulation R -value)
10131.
13.0
2. Masonry (Insulation R -value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
38.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: date:
Address of New Home: _49 Dudley Street City/FL Zip: Atlantic Beach, FL
21512020 10:45:21 AM EnergyGaugeO USA6.0.04 (Rev. 1) - FlaRes2017 FBG 8th Edition (2417) Compliant Software Page 1 of 1