Loading...
2017 Duna Vista Ct RES20-0228 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: WOLFEL JOHN JR 2017 DUNA VISTA CT ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: Pablo Creek Construction 1911 Penman Road Jacksonville Beach Fl 32250 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169506 1624 SELVA NORTE UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 2017 DUNA VISTA CT RESIDENTIAL ALTERATION RESIDENTIAL REPLACE WINDOWS AND SIDING $30000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $205.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08 TOTAL: $315.19 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/1/2020 PERMIT NUMBER RES20-0228 ISSUED: 10/1/2020 EXPIRES: 3/30/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 10/1/2020 PERMIT NUMBER RES20-0228 ISSUED: 10/1/2020 EXPIRES: 3/30/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $315.19 RES20-0228 Address: 2017 DUNA VISTA CT APN: 169506 1624 $315.19 BUILDING $205.00 BUILDING PERMIT 455-0000-322-1000 0 $205.00 BUILDING PLAN REVIEW $102.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50 STATE SURCHARGES $7.69 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08 TOTAL FEES PAID BY RECEIPT: R13582 $315.19 Printed: Thursday, October 1, 2020 9:13 AM Date Paid: Wednesday, September 30, 2020 Paid By: Leland Blake Jordan Pay Method: CREDIT CARD 382495469 1 of 1 Cashier: JJ Cash Register Receipt City of Atlantic Beach Receipt Number R13582 RES20-0228 NOA No. 20-0401.03 Expiration Date: July 30, 2025 Approval Date: July 23, 2020 7/16/20 Page 1 MIAMI–DADE COUNTY, FLORIDA PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami–Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series “SH-5500” PVC Single Hung Window – L.M.I. APPROVAL DOCUMENT: Drawing No. MD-SH5500-01 titled “Single Hung Window Installation - LM”, sheets 1 through 13 of 13, dated 05/15/15, with revision C dated 03/10/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 17-0630.05 and consists of this page 1 and evidence pages E-1, E-2, E-3 and E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. RES20-0228 Manuel Perez, P.E. Product Control Examiner NOA No. 20-0401.03 Expiration Date: July 30, 2025 Approval Date: July 23, 2020 E - 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 15-0519.05) 2. Drawing No. MD-SH5500-01 titled “Single Hung Window Installation - LM”, sheets 1 through 13 of 13, dated 05/15/15, with revision B dated 06/06/17, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No. 17-0630.05) B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a PVC sliding glass door, a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS spacer system, Duraseal® spacer system, Super Spacer® NXT™ spacer system and XL Edge™ spacer system at insulated glass, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11/16/15, 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No. 16-0714.03) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 5) Large Missile Impact Test per FBC, TAS 201-94 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 5500 PVC single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-7964, dated 11/15/14, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No. 15-0519.05) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 5500 PVC single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-7966, dated 08/21/14, signed and sealed by Idalmis Ortega, P.E. (Submitted under NOA No. 15-0519.05) Manuel Perez, P.E. Product Control Examiner NOA No. 20-0401.03 Expiration Date: July 30, 2025 Approval Date: July 23, 2020 E - 2 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5th Edition (2014), dated 05/15/15 and 08/29/17, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No. 15-0519.05) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their “Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers” dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their “SentryGlas® (Clear and White) Glass Interlayers” dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 16-0712.03 issued to ENERGI Fenestration Solutions USA for their “White Rigid PVC Exterior Extrusions for Windows and Doors” dated 08/10/17, expiring on 02/28/18. 4. Notice of Acceptance No. 16-0712.04 issued to ENERGI Fenestration Solutions USA, Inc. for their “Bronze and Lighter Shades of Cap Coated White Rigid PVC Exterior Extrusions for Windows and Doors” dated 09/15/16, expiring on 04/16/20. 5. Notice of Acceptance No. 16-0712.05 issued to ENERGI Fenestration Solutions USA, Inc. for their “Performance Core Rigid PVC Exterior Extrusions for Windows and Doors” dated 09/15/16, expiring on 04/16/20. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5th Edition (2014) and FBC 6th Edition (2017), dated June 22, 2017, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No. 17-0630.05 2. Statement letter of no financial interest, dated June 22, 2017, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under NOA No. 17-0630.05 3. Proposal No. 16-0125 issued by the Product Control Section, dated March 09, 2016, signed by Ishaq Chanda, P.E. (Submitted under NOA No. 16-0714.03) 4. Proposal issued by Product Control, dated 6/26/14 and revised on 8/19/14, signed by Jaime Gascon, P.E., Supervisor, Product Control Section. (Submitted under NOA No. 15-0519.05) Manuel Perez, P.E. Product Control Examiner NOA No. 20-0401.03 Expiration Date: July 30, 2025 Approval Date: July 23, 2020 E - 3 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED) G. OTHERS 1. Notice of Acceptance No. 16-0714.03, issued to PGT Industries, Inc. for their Series “5500” PVC Single Hung Window - L.M.I. approved on 08/18/16 and expiring on 07/30/20. 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. MD-SH5500-01 titled “Single Hung Window Installation - LM”, sheets 1 through 13 of 13, dated 05/15/15, with revision C dated 03/10/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked-up drawings and installation diagram of all PGT Industries, Inc. representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) dated 07/13/20, all signed and sealed by Idalmis Ortega, P.E C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5th Edition (2014), dated 05/15/15, 08/29/17 and updated on 03/10/20 to the new FBC 7th Edition (2020), prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) Manuel Perez, P.E. Product Control Examiner NOA No. 20-0401.03 Expiration Date: July 30, 2025 Approval Date: July 23, 2020 E - 4 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their “Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers” dated 05/09/19, expiring on 07/08/24. 2. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their “Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer” dated 05/23/19, expiring on 05/23/24. 3. Notice of Acceptance No. 18-0122.02, issued to ENERGI Fenestration Solutions USA, Inc., for their White Rigid PVC Exterior Extrusions for Windows and Doors, approved on 03/08/18, expiring on 02/28/23. 4. Notice of Acceptance No. 18-1217.15, issued to ENERGI Fenestration Solutions USA, Inc., for their Bronze and Lighter Shades of Cap Coated Rigid PVC Exterior Extrusions for Windows and Doors, approved on 01/17/19, expiring on 04/16/20. 5. Notice of Acceptance No. 18-1217.16, issued to ENERGI Fenestration Solutions USA, Inc., for their Performance Core Rigid PVC Exterior Extrusions for Windows and Doors, approved on 01/17/19, expiring on 02/04/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6th Edition (2017) and the FBC 7th Edition (2020), dated March 10, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated March 10, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 17-0630.05, issued to PGT Industries, Inc. for their Series “SH-5500” PVC Single Hung Window - L.M.I. approved on 11/30/17 and expiring on 07/30/20.