31 Seminole Rd COMM20-0009 interior buildout permitOWNER:ADDRESS:CITY:STATE:ZIP: SOLOMON PROPERTIES INC 14255 BEACH BLVD JACKSONVILLE FL 32250 COMPANY:ADDRESS:CITY:STATE:ZIP: BUILDING DYNAMICS INC.33 FAIRWAY LN JACKSONVILLE BEACH FL 32250 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170667 1000 SALTAIR SEC 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 31 SEMINOLE RD COMMERCIAL ALTERATION COMMERCIAL INTERIOR BUILDOUT - WHITE BOX $50000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $305.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $152.50 FIRE DEPARTMENT FEE 45500002080800 0 $150.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.86 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/5/2020 PERMIT NUMBER COMM20-0009 ISSUED: 10/5/2020 EXPIRES: 4/3/2021 COMMERCIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.58 TOTAL: $618.94 2 of 2Issued Date: 10/5/2020 PERMIT NUMBER COMM20-0009 ISSUED: 10/5/2020 EXPIRES: 4/3/2021 COMMERCIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION 1. SANITARY, WASTE AND VENT PIPE AND FITTINGS SHALL BE SOLID CORE DWV SCH 40 PVC, MATERIAL AS SPECIFIED, UNLESS STATEDOTHERWISE BY LOCAL CODES AND REGULATIONS. PROVIDE APPROVED FIRE RATED JACKET WHERE PIPE PASSES THROUGH RETURNAIR PLENUM.2. OFFSET VENT THRU ROOF'S (VTR'S) AS REQUIRED TO PENETRATE ROOF AT LOCATION AT LEAST 10' FROM AIR CONDITIONING UNITINTAKES AND TERMINATE A MINIMUM OF 12" (INCHES) AWAY FROM ANY VERTICAL SURFACE. COORDINATE EXACT LOCATION OF AIRCONDITIONING UNITS WITH MECHANICAL CONTRACTOR AND ADJUST AS NECESSARY. EXISTING VTR'S MAY BE RE-USED WHERESUITABLE.3. REFER TO RISERS FOR PIPE SIZES NOT SHOWN ON PLAN. REFER TO SCHEDULE FOR SANITARY DRAIN, DOMESTIC WATER ANDINDIVIDUAL VENT CONNECTION SIZES.4. REFER TO ARCHITECTURAL PLANS TO CONFIRM LOCATION OF FIRE RATED WALLS, SMOKE BARRIERS, AND SMOKE PARTITIONS. ALLPENETRATIONS OF RATED WALLS SHALL BE MADE WITH FIRE STOPPING MATERIALS IN ACCORDANCE WITH FLORIDA BUILDING CODEREQUIREMENTS. PENETRATIONS OF ALL FIRE RATED ASSEMBLIES SHALL BE MADE IN ACCORDANCE WITH THE FIRE RATEDASSEMBLY'S UL LISTING, AS APPROVED BY THE AUTHORITY HAVING JURISDICTION.5. SLEEVE ALL FLOOR/WALL PENETRATIONS THAT ARE NOT CORE BORED.6. POTABLE WATER PIPING AND FITTINGS SHALL BE CPVC WITH COMPATIBLE CPVC FITTINGS AND SOLVENT CEMENT, MATERIAL ASSPECIFIED. OR POTABLE WATER PIPING AND FITTINGS SHALL BE TYPE K COPPER BELOW GRADE AND TYPE L COPPER ABOVE GRADEAS SPECIFIED. PROVIDE APPROVED FIRE RATED JACKET WHERE PIPE PASSES THROUGH RETURN AIR PLENUM.7. INSULATE ALL HOT WATER PIPING, AND COLD WATER PIPING IN EXPOSED LOCATIONS, AS SPECIFIED.8. REFER TO WATER HEATER DETAIL FOR EMERGENCY DISCHARGE, DRAIN PAN, AND OTHER PIPING REQUIREMENTS.9. ISOLATION AND SHUTOFF VALVES AND STOP VALVES SHALL BE GATE VALVES, BALL VALVES OR ANGLE STOPS, RATED FOR 150 PSIAT 180°F. REFER TO SPECIFICATIONS.10. PROVIDE WATER HAMMER ARRESTORS FOR ALL FIXTURES IN ACCORDANCE WITH PDI 201 GUIDELINES.11. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND/OR FLOOR SINKS. PROVIDE ADA COVERING OVER TRAP PRIMERS INSTALLEDUNDER ADA LAVATORIES AND SINKS.12. ALL WATER PIPE SHALL BE RUN CONCEALED IN CHASE, WALL, OR ABOVE CEILING EXCEPT IN MECHANICAL ROOMS OR ASOTHERWISE NOTED.13. PRIOR TO ORDERING FIXTURES, CONFIRM DIMENSIONAL FIT-UP REQUIREMENTS FOR DWV PIPING LAYOUTS, FRAMING/MILLWORK,FAUCET TRIM HOLES, ETC. AND COORDINATE ANY REQUIRED ADJUSTMENTS FOR PROPER FIT FORM AND FUNCTION OF EACH FIXTURE.14. PROVIDE ALL REQUIRED FITTINGS FOR COMPLETE INSTALLATION OF EACH FIXTURE INCLUDING, BUT NOT LIMITED TO, 3/8" FLEXIBLESUPPLIES, ESCUTCHEON PLATES, STOP VALVES, DRAINS, TRAPS, MOUNTING HARDWARE, ETC. ALL EXPOSED HARDWARE SHALL BEPOLISHED BRASS OR CHROME FINISH.15. INSTALL ALL FIXTURES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, PLUMB AND LEVEL, PROPERLY SECUREDAND SEALED TO WALL OR FLOOR.16. ALL PLUMBING FIXTURES AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE FLORIDA PLUMBING CODE AND ENERGYCONSERVATION CODE, LATEST EDITION ADOPTED BY AUTHORITY HAVING JURISDICTION.17. ALL PLUMBING FIXTURES AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH FLORIDA ACCESSIBILITY CODE. ENSURESANITARY ROUGH-INS ARE LOCATED TO MAINTAIN ADA CLEARANCES AFTER FIXTURES ARE INSTALLED. REFER TO ARCHITECTURALSHEETS FOR EXACT DIMENSIONS.18. REVIEW PLANS TO CONFIRM ADEQUATE CHASE AND/OR WALL CAVITY CLEARANCE EXISTS PRIOR TO INITIATION OF WORK.19. ALL PIPING, MATERIALS AND EQUIPMENT ARE NEW UNLESS OTHERWISE NOTED.20. REVIEW BUY AMERICA(N) REQUIREMENTS WITH GENERAL CONTRACTOR. IF RELEVANT TO THIS CONTRACT, CONFIRM ALLEQUIPMENT PROVIDED MEETS THESE REQUIREMENTS, REGARDLESS OF MAKE/MODEL INDICATED ON BASIS OF DESIGN EQUIPMENTSCHEDULES.21. ALL WORK AND MATERIAL SHALL BE PERFORMED AND INSTALLED IN COMPLIANCE WITH THE 2017 FLORIDA BUILDING CODE AND ALLCURRENT AMENDMENTS. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES.22. ALL PLUMBING WORK SHALL BE INSTALLED TO AVOID INTERFERENCES WITH ELECTRICAL, MECHANICAL AND STRUCTURAL FRAMING.23. EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.24. BEFORE COMMENCEMENT OF WORK, CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS, AND CHARATERISTICS OFALL UTILITIES AND PIPING. IMMEDIATELY NOTIFY THE ARCHHITECT/ENGINEER OF ANY DISCREPANCIES.25. ALL WASTE AND VENT PIPING SHALL SLOPE AT 1/8" PER FOOT OR 1/4" PER FOOT UNLESS INDICATED OTHERWISE.26. REMOVE ALL FACTORY MARKINGS ON EXPOSED PVC PIPING. USE ACETONE, XYLENE, MEK OR ANOTHER APPROPRIATE SOLVENT.27. FLOOR CLEANOUTS SHALL BE INSTALLED FLUSH TO FINISHED FLOOR, NO DISHING PERMITTED.28. ALL VENT PIPING SHALL BE FULL LINE SIZE IF A WALL CLEANOUT IS SHOWN OR AS INDICATED.29. FLOOR DRAIN LINE SIZE AND VENTING IN ACCORDANCE WITH 2017 FLORIDA PLUMBING CODE INCLUDING LATEST REVISIONS,COMBINATION WASTE AND VENT SYSTEM.30. ALL VENT PIPING SHALL BE LOCATED WITHIN MASONRY WALLS AND OTHER WALL CONSTRUCTION THAT MAY BE USED TO ENCLOSETHE VENT PIPING. PIPING SHOWN ON DRAWINGS MAY NOT REFLECT THIS INSTALLATION METHOD BECAUSE OF THE DEGREE OF DETAILINCONSISTENT WITH 1/8" PLANS. IF PIPING CANNOT BE INSTALLED WITHIN THESE STRUCTURES, APPROVAL OF THE ENGINEER OFANOTHER INSTALLATION METHOD IS REQUIRED. ALL EXPOSED VENT PIPING SHALL BE ATTACHED TO WALL NO FURTHER THAN 3"AWAY.31. PLUMING FIXTURE DESCRIPTION SHALL TAKE PRECEDENCE WHEN EXISTS A CONFLICT WITH THE DESCRIPTION AND MODELNUMBER.PLUMBING LEGENDPROJECT GENERAL NOTESABBREVIATIONSPIPINGPROJECT PIPING NOTES1. PROVIDE TRAPEZE PIPE HANGERS FOR PIPES 3 OR MORE. DOUBLE NUT U-BOLTS EVERY THIRD HANGER. U-BOLT SHALL BE LOOSELYFASTENED. INTENT IS NOT TO BIND OR HOLD PIPE, BUT ONLY TO PROVIDE LATERAL SEPARATION.2. PROVIDE 1" X 1" X 1/8" ANGLE WELDED TO BOTH SIDES OF PIPE OF BAR JOIST IF PIPE HANGAR IS MORE THAN 6" AWAY FROM PANELPOINTS.3. PROVIDE WATER HAMMER ARRESTORS FOR ALL GANG TOILET AREAS OR ANY OTHER SINGLE OR MULTIPLE WATER USING DEVICE.4. FASTEN ALL INSULATION PIPE SHIELDS TO PIPE INSULATION WITH ADHESIVE.5. ALL PIPE SUPPORT SYSTEMS SHALL NOT CRUSH THE INSULATION WHEN RESTING UPON THE SUPPORT. THE USE OF METAL SADDLESIS NECESSARY WHEN THE WEIGHT OF PIPE EXCEEDS THE WEIGHT SUPPORT LIMIT OF THE INSULATION.6. PIPE SIZES MAY BE SHOWN FOR THE SAME PIPING ON MORE THAN ONE PLAN. IN CASE OF PIPE SIZE DISCREPANCY, THE LARGER PIPESIZE SHALL BE CONSIDERED CORRECT DURRING THE BIDDING AND DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED BY THEARCHITECT/ENGINEER OTHERWISE.7. PROVIDE SHUT-OFF VALVES FOR BOTH HOT AND COLD DOMESTIC WATER AT ALL RESTROOM LOCATIONS AND HEAT TRAPS FORWATER HEATERS.8. PROVIDE 3/4" IMCOA INSULATION ON DOMESTIC COLD WATER PIPING ABOVE CEILING.9. PIPE PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS SHALL BE INSULATED AND HAVE SPACE SEALED WITH FIRE STOPMATERIAL.10. PROVIDE A POSI-SET SYSTEM GAS CONNECTION SYSTEM FOR ALL GAS APPLIANCES.NOTE:NO PLUMBING, GAS, MECHANICAL OR ELECTRICAL CONNECTIONS OR INSTALLATIONSSHALL BE MADE UNTIL THE GENERAL CONTRACTOR, SUBCONTRACTOR ANDOWNER/TENANT HAVE FIELD VERIFIED ALL EQUIPMENT REQUIREMENTS WITHEQUIPMENT SUPPLIER.NTS NOT TO SCALEWCOSRCOOGVTRFCOCOTYP.WHAEWCHBHWCWCLEAN-OUT ON GRADESANITARY RISERWALL CLEAN-OUTCLEAN-OUTFLOOR CLEAN-OUTVENT THRU ROOFELECTRIC WATER COOLERTYPICALWATER HAMMER ARRESTORCOLD WATER LINEHOT WATER LINEHOSE BIBBFLOOR DRAINFDFS FLOOR SINKAFF ABOVE FINISHED FLOORHWP HOT WATER RETURN PUMPF FILTERED WATER LINECND CONDENSATE DRAINSAN SANITARY LINEV VENT LINEAS AQUASTATWM WATER METERCFH CUBIC FEET PER HOURMBH THOUSAND BTU'S PER HOURPSI POUNDS PER SQUARE INCHWC WATER COLUMNWR WATER RISERET EXPANSION TANKBTU BRITISH THERMAL UNITAHJ AUTHORITIES HAVING JURISDICTIONTMV TEMPERATURE MIXING VALVEGI GREASE INTERCEPTORLINT INTERCEPTORLIGPF GALLONS PER FLUSHGPM GALLONS PER MINUTETPV TRAP PRIMER VALVEWSV WASTE STACK VENTCA COMPRESSED AIRVS VENT STACKWS WASTE STACKAC AIR COMPRESSORBTS BARRIER TYPE SEAL-TRAP PRIMEREWH ELECTRIC WATER HEATERFUNNEL FLOOR DRAINFNDGR GAS REGULATORGWH GAS WATER HEATERHD HUB DRAININSTANTANEOUS WATER HEATERIWHICE MAKER VALVE BOXIVBPRV PRESSURE REDUCING VALVERVB REFRIGERATOR VALVE BOXRD ROOF DRAINSD SHOWER DRAINSP SUMP PUMPTD TRENCH DRAINWVB CLOTHES WASHER VALVE BOXWALL HYDRANTHYYH YARD HYDRANTPOINT OF CONNECTION TOEXISTINGPOINT OF DISCONNECTIONFROM EXISTINGFORCE MAINFMRL RAIN LEADERAAV AIR ADMITTANCE VALVEHOT WATER RETURN LINEHWRGW GREASE WASTE LINEBFG BELOW FINISHED GRADEBFF BELOW FINISHED FLOORECO EXTERIOR CLEAN-OUTGAS GAS LINEPROJECT DEMOLITION NOTES1. REMOVE EXISTING PLUMBING FIXTURES, EQUIPMENT, AND EQUIPMENT PADS TOTHE EXTENT INDICATED ON THE ING AND ARCHITECTURAL DEMOLITION DRAWINGS.2. REMOVE EXISTING WATER PIPING TO THE EXTENT INDICATED ON THE DRAWINGS.POINTS OF DISCONNECTION/RECONNECTION ON DRAWINGS ARE BASED BESTAVAILABLE INFORMATION AND SHALL BE FIELD LOCATED AND ADJUSTEDACCORDINGLY. UNLESS OTHERWISE INDICATED, INACCESSIBLE EXISTINGUNDERSLAB PIPING NOT INTERFERING WITH NEW CONSTRUCTION MAY BEABANDONED IN PLACE AFTER COMPLETELY DISCONNECTING FROM NEW SYSTEM,DRAINING, CUTTING AND CAPPING BELOW GRADE.3. REMOVE EXISTING SANITARY, WASTE, & VENT PIPING SYSTEMS TO THE EXTENTINDICATED ON THE DRAWINGS. POINTS OF DISCONNECTION/RECONNECTION ONPLANS ARE BASED BEST AVAILABLE INFORMATION AND SHALL BE FIELD LOCATEDAND ADJUSTED ACCORDINGLY. INACCESSIBLE EXISTING UNDERSLAB PIPING NOTINTERFERING WITH NEW CONSTRUCTION MAY BE ABANDONED IN PLACE AFTERCOMPLETELY DISCONNECTING FROM NEW SYSTEM, DRAINING, CUTTING ANDCAPPING BELOW GRADE. EXISTING VTR'S OF REQUIRED SIZE AND ACCEPTABLECONDITION MAY BE RE-USED.4. EXISTING PIPING TO BE RE-USED IS SHOWN FADED.5. RECOVER ALL REFRIGERANT IN ACCORDANCE WITH ALL FEDERAL, STATE ANDLOCAL REQUIREMENTS.6. PROPERLY DISPOSE OF ALL REMOVED MATERIAL OFFSITE.7. ALL EQUIPMENT BEING REUSED SHALL BE INSPECTED FOR PROPER OPERATIONAND REASONABLE CONDITION AND SHALL BE PRESSURE TESTED WITH THE NEWSYSTEM. ALL PIPING BEING REUSED SHALL BE VISUALLY INSPECTED FORREASONABLE CONDITION, SLOPE AND INVERT, AS APPLICABLE; AND SHALL BEFLUSHED AND PRESSURE TESTED.8. EXISTING PLUMBING SYSTEM, WHERE INDICATED, ARE BASED ON BEST AVAILABLEINFORMATION. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING AND FIELDCONFIRM EXTENT OF DEMOLITION, EXISTING INVERTS, ETC. CONTRACTOR SHALLCONFIRM ALL EXISTING CONDITIONS AS DEMOLITION OCCURS. REFER TO ORIGINALCONSTRUCTION DRAWINGS WHERE AVAILABLE FOR ADDITIONAL INFORMATION OFEXISTING CONDITIONS.ELBOW (PLAN, UP, DOWN)SHUT-OFF VALVES (GATE/BALL VALVES)BRANCH CONNECTIONS (TOP, BOTTOM, SIDE)TEE (PLAN, UP, DOWN)TRAP, PLAN VIEWHOT WATERSANITARYVENTCOLD WATERHOT WATER RETURNGASGASNATURAL GAS/PROPANEEXISTING SANITARY (FADED)EXISTING COLD WATER (FADED)EXISTING HOT WATER (FADED)EXISTING HOT WATER RETURN (FADED)CAP FOR FUTURE CONNECTIONGAS BALL OR PLUG VALVEDIRECTION OF FLOWCIRCUIT BALANCING VALVE WITH MEMORY STOPPRESSURE REDUCING VALVEUNIONCLEANOUT IN FLOORCLEANOUT ON END OF PIPEHOSE BIBBFLOOR DRAIN, FLOOR SINKWATER HEATER RELIEFEXISTING VENT (FADED)AACOMPRESSED AIRFILTERED COLD WATERDEMOLITIONREDUCED PRESSURE BACKFLOW PREVENTERHOT WATER RECIRCULATION PUMPPCHECK VALVEWATER METERMCONTINUATIONCAP PIPING FOR FUTURE USEPLUMBING LEGEND AND NOTES P-1SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROAD PLUMBING SCHEDULES P-2SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROAD ..CHM . (TYP.)CHM. M.PLUMBING PLANS AND SANITARY RISER P-3SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROADPARTIAL SANITARY WASTE PLANSCALE: 1/4"= 1'-0"SCALE: 1/4" = 1'-0"0 2' 4' 8'SCALE: N.T.S.SANITARY RISER 1PARTIAL DOMESTIC WATER PLANSCALE: 1/4"= 1'-0"SCALE: N.T.S.SANITARY RISER 2 FLOW TOFIXTUREPLUMBING DETAILS P-4SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROAD SCALE: N.T.S.INSTANTANEOUS ELECTRIC WATER HEATER DETAIL (IWH)SCALE: N.T.S.ANTI-SCALD DEVICE DETAIL (TMV-P)SCALE: N.T.S.FLOOR DRAIN DETAIL (FD)SCALE: N.T.S.TRAP PRIMER DETAIL (TPV)SCALE: N.T.S.WALL CLEANOUT DETAIL (WCO) MECHANICAL GENERAL NOTESSYMBOL LEGENDABBREVIATIONS1. ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, AND TRANSITION AROUNDOBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COSTS.2. LOCATE ALL RTU's, EF's, AND OTHER SERVICEABLE MECHANICAL EQUIPMENT A MINIMUM OF 10 FT FROM THE ROOFEDGE. GUARDS SHALL BE PROVIDED WHERE SERVICEABLE MECHANICAL EQUIPMENT IS LOCATED WITHIN 10 FT. OF AROOF EDGE. THE GUARD SHALL EXTEND NOT LESS THAN 30 IN. BEYOND EACH END OF SUCH EQUIPMENT, AND THE TOPOF THE GUARD SHALL BE LOCATED NOT LESS THAN 42 IN. ABOVE THE ELEVATED SURFACE ADJACENT TO THE GUARD.3. PROVIDE CONICAL TAKE-OFFS FOR ALL TAPS INTO DUCTWORK WITH VOLUME DAMPERS AT EACH TAKE-OFF FOR CFMADJUSTMENT.4. COORDINATE DIFFUSER BOXES, SUPPLY, RETURN GRILLES AND OTHER MECHANICAL DEVICES WITH LIGHT FIXTURESWHERE THE AIR DISCHARGES DIRECTLY ON THE FIXTURE. ENGINEER MUST BE NOTIFIED IN ALL CASES WHERECOORDINATION IS IN QUESTION.5. HORSEPOWER RATINGS ON MOTORS ARE BASED ON SCHEDULED EQUIPMENT AND DESIGN CONDITIONS. ACTUAL FIELDCONDITIONS OR SUBSTITUTIONS FROM SCHEDULED EQUIPMENT MAY REQUIRE DIFFERENT HORSEPOWER. IF LARGERMOTOR SIZES ARE REQUIRED OR CHANGES OCCUR IN VOLTAGES, COORDINATE ELECTRICAL SERVICE TO ENSUREPROPER WIRE SIZES AND DEVICES AT NO ADDITIONAL COMPENSATION (DUE TO THESE CHANGES) ASKED FOR ORREQUESTED BY ANOTHER CONTRACTOR OR TRADE. ADDITIONAL COMPENSATION RESULTING FROM EQUIPMENTSUBMITTED FOR REASONS OF CONTRACTOR PREFERENCE OR AVAILABILITY, SHALL BE PAID BY THIS CONTRACTORWITH NO ADDITIONAL EXPENSE TO THE OWNER.6. CONTRACT DRAWINGS ARE BASED ON THE EQUIPMENT SPECIFIED. MAKE ADJUSTMENTS, MODIFICATIONS OR CHANGESREQUIRED, DUE TO USE OF OTHER EQUIPMENT, WITH NO ADDITIONAL COMPENSATION EXPECTED FOR OR DEMANDEDBY THIS CONTRACTOR OR ANY OTHER CONTRACTOR OR TRADE. ANY ADDITIONAL COMPENSATION AS A RESULT OFCHANGES IN EQUIPMENT, STRUCTURAL FRAMING, CONCRETE FOUNDATION, OR OTHER PHYSICAL CHANGES SHALL BEBORE BY THIS CONTRACTOR, WITH NO ADDITIONAL EXPENSE TO THE OWNER.7. PROVIDE THERMOSTATS FOR ALL RTU's WHETHER SHOWN OR NOT. IF LOCATION IS NOT SHOWN ON DRAWINGS,CHECK WITH ENGINEER FOR EXACT PLACEMENT. LOCATIONS SHOWN ARE APPROXIMATE, AND MAY NEED TO BEADJUSTED DUE TO FURNITURE LOCATIONS OR OTHER OBSTRUCTIONS. THERMOSTATS LOCATED IN PUBLIC AREASSHALL BE IN A LOCKABLE CASE.8. PROVIDE SMOKE DETECTORS IN SUPPLY DUCTS FOR ALL RTU'S THAT DELIVER 2000 CFM OF SUPPLY AIR OR GREATERFOR UNIT SHUTDOWN. CONTRACTOR SHALL PROVIDE AUDIBLE AND VISUAL ALARM IN A CONSTANTLY OCCUPIEDLOCATION. ALARM SHALL BE LABELED "DUCT TROUBLE".9. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2017 FLORIDA MECHANICAL CODE, WITH ALL REVISIONS,NFPA 90A AND ASHRAE 62-2001.10. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AIR BALANCE REPORT, EQUIPMENT AND LABOR WARRANTIESAND PROVIDE A COMPLETE, OPERATIONAL MECHANICAL SYSTEM IN COMPLIANCE WITH ALL APPLICABLE CODES.11. MAINTAIN A MINIMUM OF 10'-0" BETWEEN ALL OUTDOOR INTAKES AND ANY VENTS OR EXHAUSTS.12. ALL DUCTWORK LOCATED IN UNCONDITIONED SPACES SHALL BE INSULATED WITH A MINIMUM R-6.13. RTU's SHALL HAVE AN OUTDOOR AIR INTAKE BALANCED TO SCHEDULED VALUES.14. ROUTE CONDENSATE FROM RTU'S TO NEAREST ROOF DRAINS.15. RTU CONCEALED DUCTWORK SHALL BE CONSTRUCTED WITH SHEET METAL OR DUCTBOARD PER LATEST SMACNASTANDARDS.16. ALL RTU'S AND EF'S SHALL BE INSTALLED ON FACTORY INSULATED ROOF CURBS.17. ALL ROOF CURBS SHALL BE FABRICATED SO THAT THE TOP OF CURB IS LEVEL WITH THE HORIZON REGARDLESS OFROOF PITCH.18. ALL UNITS SHALL HAVE INSULATED DRAIN PANS AND SHALL BE INTERNALLY INSULATED AND WATERPROOFED.CONDENSATE SHALL BE SIZED AND TRAPPED PER MANUFACTURER'S RECOMMENDATIONS.19. RTU CASINGS SHALL BE DIEFORMED STEEL WITH SMOOTH PANEL CONSTRUCTION WITHOUT SHARP ANGLES OR EDGES.ALL COMPONENT SECTIONS SHALL HAVE REMOVABLE PANELS FOR ACCESS TO THE INTERIOR.20. PROVIDE ENGINEER OF RECORD WITH HVAC EQUIPMENT CUT SHEETS. CUT SHEETS SHALL BE APPROVED PRIOR TOINSTALLATION.21. THE MECHANICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID FOR THE PROJECT. THEMECHANICAL CONTRACTOR SHALL COORDINATE DUCTWORK LOCATIONS DESIGNED BY THE MECHANICAL ENGINEERAND FIELD VERIFY ANY OBSTACLES OR CONFLICTS AND NOTE THEM IMMEDIATELY TO THE ENGINEER. NO DUCTWORKSHALL BE FABRICATED PRIOR TO FIELD VERIFYING ALL EXISTING CONDITIONS.NOTE: SOME SYMBOLS SHOWN DO NOT PERTAIN TO THIS PROJECTMECHANICAL DRAWING LISTM-1 MECHANICAL GENERAL NOTES, ABBREVIATIONS AND LEGENDM-2 MECHANICAL SCHEDULES, PLAN AND DETAILSTHERMOSTAT/SENSORSUPPLY AIRFLOWRETURN/ EXHAUST AIRFLOWDEHUMIDISTATAIR DEVICE TYPECFM AMOUNTSMOKE DETECTORDUCT TEMPERATURE SENSORCEILING RETURN AIR GRILLECEILING EXHAUST AIR GRILLEMANUAL VOLUME DAMPERCEILING SUPPLY AIR DIFFUSERNEW RECTANGULAR DUCT(INSIDE DIMENSIONS; WIDTH X DEPTH)FLEX DUCT (INSIDE DIMENSION)NEW ROUND DUCT (INSIDE DIMENSION)EXISTING DUCT TO REMAINEXISTING DUCT TO BE REMOVEDCONNECT NEW DUCT TO EXISTING DUCTTRUNCATE DUCT - LIMIT OF DEMOLITIONVANED ELBOWRADIUS ELBOWTRANSITION - CONCENTRICTRANSITION - ECCENTRICSQUARE TEESUPPLY DUCT (UP & DOWN)RETURN DUCT (UP & DOWN)EXHAUST DUCT (UP & DOWN)ROUND DUCT (UP & DOWN)STANDARD BRANCH TAKE-OFFDUCT / WALL MOUNTED SUPPLY REGISTER / GRILLEDUCT / WALL MOUNTEDRETURN/ EXHAUST REGISTER / GRILLEABV ABOVEAFF ABOVE FINISH FLOORAHU AIR HANDLING UNITBDD BACKDRAFT DAMPERBHP BRAKE HORSEPOWERBTU BRITISH THERMAL UNITCFM CUBIC FEET PER MINUTECIRC CIRCULARCU CONDENSING UNITDCI DUCTLESS CEILING-CASSETTE INDOORDCO DUCTLESS CEILING-CASSETTE OUTDOORDN DOWNDWI DUCTLESS WALL-MOUNTED INDOORDWO DUCTLESS WALL-MOUNTED OUTDOOREAT ENTERING AIR TEMPERATUREEDB ENTERING DRY-BULB (TEMPERATURE)EER ENERGY EFFICIENCY RATIOEF EXHAUST FANESP EXTERNAL STATIC PRESSUREEWB ENTERING WET-BULB (TEMPERATURE)EX EXISTINGFD FIRE DAMPERFF FLY FAN (AIR CURTAIN)FLA FULL LOAD AMPSFPM FEET PER MINUTEFT FEETGPM GALLON PER MINUTEHP HEAT PUMPHP HORSEPOWERHUM HUMIDIFIERIN INCHESIRH INFRARED HEATERSKEF KITCHEN EXHAUST FANKW KILOWATTLLOUVERLAT LEAVING AIR TEMPERATUREMBH THOUSANDS BTUs PER HOURMCA MINIMUM CIRCUIT AMPSMOCP MAXIMUM OVER CURRENT PROTECTIONMOD MOTOR OPERATED CONTROL DAMPERMUA MAKE-UP AIR UNITNA NOT APPLICABLENC NOISE CRITERIANC NORMALLY CLOSEDNO NORMALLY OPENNTS NOT TO SCALEOA OUTSIDE AIROD OUTSIDE DIAMETERPSI POUNDS PER SQUARE INCHRA RETURN AIRRECT RECTANGULARRH RELATIVE HUMIDITYRLA RUN LOAD AMPERERTU ROOFTOP AIR HANDLING UNITRPM REVOLUTION PER MINUTESA SUPPLY AIRSEER SEASONAL ENERGY EFFICIENCY RATIOSF SUPPLY FANSS STAINLESS STEELSP STATIC PRESSURETYP TYPICALUC UNDERCUT DOORUNO UNLESS NOTED OTHERWISEUTR UP THROUGH ROOFV/PH VOLTS/PHASEVCD VOLUME CONTROL DAMPERVAV VARIABLE AIR VOLUMEVD VOLUME DAMPER(MANUAL OPPOSED BLADE)VFD VARIABLE FREQUENCY DRIVEW WATTSWEF WALL EXHAUST FAN SHEET TITLE:SHEETDATE:DRAWN BY:CHECKED BY:DTDCMD07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.CAREN M. DOHERTY, P.E.CAREN M. DOHERTY, P.E. FL P.E. #-55021 NO.REVISIONDATE SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROAD MECHANICAL NOTES, LEGEND AND ABBREVIATIONS M-1 ELECTRIC ROOFTOP UNITSMARKINDOOR FAN DATACOOLING CAPACITYEERMCA(A)MOCP(A)HEATERRATING(KW)ELECTRICAL DATAUNITWEIGHT(LBS)BASIS OF DESIGN NOTESTOTALFLOW(CFM)0/A(CFM)ESP(W.G.)MOTOR(HP)EDB(°F)EWB(°F)AMBIENT(°F)TOTAL(BTU/HR)SENSIBLE(BTU/HR)VOLTS HZ PHASERTU-1 2000 250 0.5 2.9 79.4 66.1 9562,200 44,40012.136.8 45 10.5 208 60 3 631JOHNSON CONTROLSZQE06A2C1AA1C111A31-6RTU-2 1600 130 0.52.478 65.3 9549,200 34,90012.0 23.7 35 6.5 208 60 3 552JOHNSON CONTROLSZQE05A2B1AA1C111A31-2, 4-6 NOTES: 1. UNITS PROVIDED SHALL MEET ALL SCHEDULED VALUES REGARDLESS OF MODEL OR TYPE, UNLESS APPROVED BY THE ENGINEER. 2. PROVIDE PROGRAMMABLE THERMOSTATS FOR ALL RTU'S. MOUNT @ 48" AFF. 3. PROVIDE DUCT MOUNTED SMOKE DETECTOR IN SUPPLY AIR, WIRED TO SHUT DOWN RTU. POWER WIRING BY ELECTRICAL CONTRACTOR, CONTROL (24VAC) WIRING BY MECHANICAL CONTRACTOR. 4. ELECTRICAL CONTRACTOR TO INSTALL DISCONNECT AND CONVENIENCE OUTLETS ON BOTH UNITS. 5. INSTALL AQUAGUARD AG-3180E SENSOR W/ CORRESPONDING AQUAGUARD AUDIO & VISUAL REMOTE ALARM. 6. PROVIDE SYSTEM ECONOMIZER.EXHAUST FAN SCHEDULEMARKSERVICETOTAL AIR(CFM)E.S.P.(W.G)UNIT TYPEDRIVEPOWER (W)FLA VOLTS/PH/HZ MANUFACTURER MODEL NUMBER NOTESEF-1,2TOILET ROOM700.13CEILING DIRECT150.27115/1/60GREENHECK SP-A701,2 NOTES: 1. INTERLOCK WITH LIGHT SWITCH. 2. PROVIDE BACKDRAFT DAMPER.EF-1EF-26"Ø UP T0ROOF W/ CAP6"Ø UP T0ROOF W/ CAPRTU-2RTU-1DUCT DOWNINTO SPACEFOR FUTUREDUCTWORKDUCT DOWNINTO SPACEFOR FUTUREDUCTWORKMERCANTILEOPENAREA101BUSINESSOPENAREA103TOILET102TOILET104SHEET TITLE:SHEETDATE:DRAWN BY:CHECKED BY:DTDCMD07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.CAREN M. DOHERTY, P.E.CAREN M. DOHERTY, P.E. FL P.E. #-55021 NO.REVISIONDATE SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROAD MECHANICAL SCHEDULES, PLAN AND DETAILS M-2SCALE:1/4"=1'-0"MECHANICAL PLANSCALE: N.T.S.RTU CONNECTION DETAILSCALE: N.T.S.TOILET EXHAUST DETAILSCALE: N.T.S.CONDENSATE DRAIN DETAIL UPUPUPUSUSUSOHPOHPOHSOHSSHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:JAGCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROADE-1ELECTRICAL LEGEND & PROJECT GENERAL NOTES EF-1EF-2RTU-2RTU-1SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:JAGCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROADE-2ELECTRICAL PLANSCALE: 3/8"= 1'-0"ELECTRICAL PLAN SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:JAGCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROADE-3POWER RISER DIAGRAM KEY NOTESGENERAL NOTESSCALE: NTSPOWER RISER DIAGRAM SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:JAGCMDREVISIONDATE 07-27-20370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021SHELL SPACE ATLANTIC BEACH, FLORIDA 32233 VANILLA SHELL BUILD-OUT 31 SEMINOLE ROADE-4ELECTRICAL SCHEDULES & DETAILSSCALE: NTSGROUNDING DETAILSCALE: NTSGROUND BAR DETAIL L--____ _ Short Desc: Seminole Rd Store Owner: Addressl: 31 Seminole Road Address2: Type: Retail PROJECT SUMMARY Description: Seminole Rd Store Shell City: Atlantic Beach State: Florida Zip: 32233 Class: Renovation to existing buildi Jurisdiction: ATLANTIC BEACH, DUVAL COUNTY, FL (261100) Conditioned Area: 2226 SF Conditioned & UnConditioned Area: 2226 SF No of Stories: 1 Permit No: 0 Area entered from Plans 2400 SF Max Tonnage 5.2 If different, write in: Building Rotation: 2 Deg Clockwise. Walls & windows will be rotated accordingly EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option 7/27/2020 Page 2 of 24 '------------- Compliance Summary Component Design Criteria Result Gross Energy Cost (in $) 2,640.0 3,140.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVACSYSTEM PASSES PLANT No Entry WATER HEATING SYSTEMS PASSES PIPING SYSTEMS PASSES Met all required compliance from Check List? YeslNolNA IMPORTANT MESSAGE Info 5009 --- --An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option 7/27/2020 Page 3 of24 ~--- CERTIFICATIONS Florida Energy Code d I hereby certify that the plans aLWpecify' .ti9ns covered by this calculation are in compliance with the Prepared By: M. Jh~ Building Official: ______ _ Date: 1 (d.-1 (~ Date I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: ______ _ Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Craig A. Sommers Reg No: AR0016480 Electrical Designer: Caren M. Doherty Reg No: 55021 Lighting Designer: Caren M. Doherty Reg No: 55021 Mechanical Designer: Caren M. Doherty Reg No: 55021 Plumbing Designer: Caren M. Doherty Reg No: 55021 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option 7/27/2020 Page 4 of24 ~---- Project: Seminole Rd Store Title: Seminole Rd Store Shell Type: Retail (WEA File: FL""JACKSONVILLE INTL ARPT.tm3) Building End Uses 1) Proposed 2) Baseline Total 169.40 206.20 $2,640 $3,140 ELECTRICITY(MBtu/kWh/$) 169.40 206.20 49624 60424 $2,640 $3,140 AREA LIGHTS 1.90 59.10 551 17315 $29 $900 MISC EQUIPMT 32.60 32.60 9547 9547 $508 $496 PUMPS & MISC 0.10 0.10 25 41 $1 $2 SPACE COOL 56.10 66.83 16446 19580 $875 $1,018 SPACE HEAT 7.40 20.13 2161 5898 $115 $307 VENT FANS 71.30 27.45 20894 8044 $1,112 $418 Credits Applied: None I PASSES Passing Criteria = 3140 Design (including any credits) = 2640 Passing requires Proposed Building cost to be at most 100% of Baseline cost. This Proposed Building is at 84.1 % EnergyGauge Summit® FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASHRAE 90.1-2013 -Energy Cost Budget Option vnn~ P~5~M I ~---~-~-~ -~ ----------------- Project: Seminole Rd Store Title: Seminole Rd Store Shell Type: Retail ~WEA File: FL JACKSONVILLE INTL ARPT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (WlUnit) or No. of Units (W) (W) (Sqft or ft) Ext Light 1 Canopies (freestanding, attached Yes 0.80 430.0 344 and Overhangs) Ext Light 2 Building facades (by linear foot) No 3.75 lOO.O 375 Tradable Surfaces: 156 (W) Allowance for Tradable: 1094 (W) I PASSES All External Lighting: 276 (W) Complicance check includes a excesslBase allowance of 750.00(W) Project: Seminole Rd Store Title: Seminole Rd Store Shell Type: Retail (WEA File: FL ... JACKSONVILLE INTL ... ARPT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compliance ID (sq.ft) CP CP Shell 25,001 Sales Area 1,310 3 1 PASSES Toilet 25,001 Sales Area 48 1 1 PASSES Shell 25,001 Sales Area 820 3 1 PASSES Toilet 25,001 Sales Area 48 1 1 PASSES I PASSES EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option I 7/27/2020 Page 6 of24 156 120 I L-... __ . Project: Seminole Rd Store Title: Seminole Rd Store Shell Type: Retail (WEAFile: FL JACKSONVILLE INTL ARPT.tm3) System Report Compliance RTU-l RTU-l Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 62200 14.00 14.00 12.90 PASSES Cooled 0 to 65000 Btu/h Cooling Capacity Heating System Electric Furnace 35800 1.00 1.00 PASSES Air Handling Air Handler (Supply) -2000 0.80 0.82 Not Required System -Supply Constant Volume RTU-2 RTU-2 Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 49200 14.00 14.00 14.00 PASSES Cooled 0 to 65000 Btu/h Cooling Capacity Heating System Electric Furnace 22200 1.00 1.00 PASSES Air Handling Air Handler (Supply) -1600 0.80 0.82 PASSES System -Supply Constant Volume I PASSES I Plant Compliance Description Installed Size Design Min Design Min Category No Eff Eff IPLV IPLV I None EnergyGauge Summit® FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASHRAE 90.1-2013 -Energy Cost Budget Option Comp Hance I 7/27/2020 Page 7 of24 Insulation 5.8.1.7.3 Envelope Insulation in contact with the ground has <=0.3% 0 water absorption rate per ASTM C272. Air Leakage 5.4.3.4 Envelope Vestibules are installed where building entrances 0 separate conditioned space from the exterior, and meet exterior envelope requirements. Doors have self-closing devices, and are >=7 ft apart (>= 16 ft apart for adjoinging floor area >= 40000 sq.ft.). Vestibule floor area <=7 50 sq.ft. or 2 percent of the adjoining conditioned floor area. 0 HVAC 6.4.3.4.4 Mechanical Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. HVAC 6.4.3.8 Mechanical Demand control ventilation provided for spaces 0 >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. 0 HVAC 6.4.4.1.4 Mechanical Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. HVAC 6.5.2.3 Mechanical Dehumidification controls provided to prevent 0 reheating, recooling, mixing of hot and cold airstreams or concurrent heating and COOling of the same airstream. SYSTEM_SPECIFIC 6.5.3.1.3 Mechanical Fans have efficiency grade (FEG) >= 67. The total 0 efficiency of the fan at the design point of operation <= 15% of maximum total efficiency of the fan. SYSTEM_SPECIFIC 6.5.3.5 Mechanical Motors for fans >= 1/12 hp and < 1 hp are 0 electronically-commutated motors or have a minimum motor effiCiency of 70%. These motors are also speed adjustable for either balancing or remote control. SYSTEM_SPECIFIC 6.4.3.10 Mechanical DOC system installed and capable of providing 0 control logic including monitoring zone and system demand for fan pressure, pump pressure, heating, and cooling; transferring zone and system demand information from zones to air distribution system controllers and from air distribution systems to heating and cooling plant controllers; automatically detecting and alerting system operator when zones and systems excessively drive the reset logic; allow operator removal of zone(s) from the reset algorithm; AND capable of trending and graphically displaying input and output pOints. 0 SYSTEM_SPECIFIC 6.5.3.2.3 Mechanical Reset static pressure setpoint for DOC controlled VAV boxes reporting to central controller based on the zones requiring the most pressure. Controls provide: zone damper monitoring or indicator of static pressure need; autodetection, alarm, and operator override of zones excessively triggering reset logic. 0 SYSTEM_SPECIFIC 6.5.3.3 Mechanical Multiple zone VAV systems with DOC of individual zone boxes have static pressure setpoint reset controls. SYSTEM_SPECIFIC 6.5.3.4 Mechanical Multiple zone HVAC systems have supply air 0 temperature reset controls. SYSTEM_SPECIFIC 6.5.4.1 Mechanical System turndown requirement met through 0 multiple single-input boilers, one or more modulating boilers, or a combination of single-input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtu/h has 3:1 turndown ratio, boiler input between 5.0 MBtu/h and 10 MBtu/h has 4:1 turndown ratio, boiler input> 10.0 MBtu/h has 5:1 turndown ratio. 0 HVAC 6.5.4.2 Mechanical HVAC pumping systems >10 hp designed for variable fluid flow. SYSTEM_SPECIFIC 6.5.4.3, 6.5.4.3.1, Mechanical Fluid flow shutdown in pumping systems to 0 6.5.4.3.2 multiple chillers or boilers when systems are shut down. EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7/27/2020 Page 11 of24 Insulation 5.8.1.7 Envelope Exterior insulation protected against damage, D D D sunlight, moisture, wind, landscaping and equipment maintenance activities. D D D HVAC 6.4.3.7 Mechanical Freeze protection and snow/ice melting system sensors for future connection to controls. Air Leakage 5.4.3.1 Envelope Continuous air barrier is wrapped, sealed, D D D caulked, gasketed, and/or taped in an approved manner, except in semiheated spaces in climate zones 1-6. Air Leakage 5.4.3.2 Envelope Factory-built and site-assembled fenestration and D D D doors are labeled or certified as meeting air leakage requirements. D D D Fenestration 5.8.2.1, 5.8.2.3, Envelope Fenestration products rated (U-factor, SHGC, and 5.8.2.4, 5.8.2.5 VT) in accordance with NFRC or energy code defaults are used. Fenestration 5.8.2.2 Envelope Fenestration and door products are labeled, or a D D D signed and dated certificate listing the U-factor, SHGC, VT, and air leakage rate has been provided by the manufacturer. D D D SYSTEM_SPECIFIC 7.4.4.1 Mechanical Temperature controls installed on service water heating systems «=120AoF to maximum temperature for intended use). D D D SYSTEM_SPECIFIC 7.4.4.2 Mechanical Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. SYSTEM_SPECIFIC 7.4.6 Mechanical Heat traps installed on non-circulating storage D D D water tanks. HVAC 6.4.1.4, 6.4.1.5 Mechanical HVAC equipment efficiency verified. Non-NAECA D D D HVAC equipment labeled as meeting 90.1. SYSTEM_SPECIFIC 6.4.1.5.2 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. D D D labeled for replacement only. HVAC 6.4.3.4.1 Mechanical Stair and elevator shaft vents have motorized D D D dampers that automatically close. HVAC 6.4.3.4.2, 6.4.3.4.3 Mechanical Outdoor air and exhaust systems have motorized D D D dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. D D D HVAC 6.4.3.4.5 Mechanical Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. D D D HVAC 6.5.3.2.1 Mechanical OX cooling systems >= 75 kBtu/h (>= 65 kBtu/h effective 1/2016) and chilled-water and evaporative cooling fan motor hp >= A~ designed to vary indoor fan airflow as a function of load and comply with operational requirements. 0 0 0 HVAC 6.4.4.1.1 Mechanical Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. D D HVAC 6.4.4.1.2 Mechanical HVAC ducts and plenums insulated. Where ducts 0 or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. D 0 D HVAC 6.4.4.1.3 Mechanical HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. D 0 D HVAC 6.4.4.2.1 Mechanical Ducts and plenums sealed based on static pressure and location. SYSTEM_SPECIFIC 6.4.4.2.2 Mechanical Ductwork operating >3 in. water column requires 0 0 D air leakage testing. SYSTEM_SPECIFIC 6.5.2.1 Mechanical Zone controls can limit simultaneous heating and 0 0 D cooling and sequence heating and cooling to each zone. SYSTEM_SPECIFIC 6.5.2.2.2 Mechanical Two-pipe hydronic systems using a common 0 0 D distribution system have controls to allow a deadband >=15 AOF, allow operation in one mode for at least 4 hrs before changeover, and have rest controls to limit heating and cooling supply temperature to <=30 AOF. EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option 7/27/2020 Page 13 of24 HVAC 6.5.2.4.1 Mechanical Humidifiers with airstream mounted preheating 0 0 0 jackets have preheat auto-shutoff value set to activate when humidification is not required. HVAC 6.5.2.4.2 Mechanical Humidification system dispersion tube hot 0 0 0 surfaces in the airstreams of ducts or air-handling units insulated >= R-0.5. SYSTEM_SPECIFIC 6.5.3.2.2 Mechanical VAV fans have static pressure sensors positioned 0 0 0 so setpoint <=1.2 in. w.c. design pressure. SYSTEM_SPECIFIC 6.5.4.5.1 Mechanical Two-position automatic valve interlocked to shut 0 0 0 off water flow when hydronic heat pump with pumping system >10 hp is off. 0 0 0 SYSTEM_SPECIFIC 6.5.6.2 Mechanical Condenser heat recovery system that can heat water to 85 AOF or provide 60% of peak heat rejection is installed for preheating of service hot water. HVAC 6.5.7.1.5 Mechanical Approved field test used to evaluate design air 0 0 0 flow rates and demonstrate proper capture and containment of kitchen exhaust systems. 0 0 0 SYSTEM_SPECIFIC 6.5.9 Mechanical Hot gas bypass limited to: <=240 kBtu/h s€" 15% >240 kBtu/h s€" 10% HVAC 6.4.3.9 Mechanical Heating for vestibules and air curtains include 0 0 0 automatic controls that shut off the heating system when outdoor air temperatures> 45F. Vestibule heating systems controlled by a thermostat in the vestibule with setpoint <= 60F. Controls 6.5.10 MeChanical Doors separating conditioned space from the 0 0 0 outdoors have controls that disable/reset heating and cooling system when open. 0 0 0 Controls 9.4.1.1 Interior Lighting Automatic control requirements prescribed in Table 9.6.1, for the appropriate space type, are installed. Mandatory lighting controls (labeled as 'REO') and optional choice controls (labeled as 'ADD1' and 'ADD2') are implemented. 0 Controls 9.4.1.1 Interior Lighting Independent lighting controls installed per 0 0 approved lighting plans and all manual controls readily accessible and visible to occupants. 0 0 0 Controls 9.4.1.2 Interior Lighting Parking garage lighting is equipped with required lighting controls and daylight transition zone lighting. 0 0 0 Controls 9.4.1.1f Interior Lighting Daylight areas under skylights and roof monitors that have more than 150 W combined input power for general lighting are controlled by photocontrols. Controls 9.4.1.4 Exterior Lighting Automatic lighting controls for exterior lighting 0 0 0 installed. Controls 9.4.1.3 Interior Lighting Separate lighting control devices for specific uses 0 0 0 installed per approved lighting plans. Wattage 9.6.2 Interior Lighting Additional interior lighting power allowed for 0 0 0 special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Wattage 9.6.4 Interior Lighting Where space LPD requirements are adjusted 0 0 0 based on room cavity ratios, dimensions are consistent with approved plans. 0 0 0 Insulation 5.5.3.1 Envelope Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. 0 Insulation 5.8.1.2, 5.8.1.3 Envelope Roof insulation installed per manufacturers€™s 0 0 instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. 0 0 0 Insulation 5.8.1.1 Envelope Building envelope insulation is labeled with R-value or insulation certificate has been provided listing R-value and other relevant data. 0 0 0 Insulation 5.8.1.9 Envelope Building envelope insulation extends over the full area of the component at the proposed rated R or U value. Insulation 5.8.1.4 Envelope Eaves are baffled to deflect air to above the 0 0 0 insulation. Insulation 5.8.1.5 Envelope Insulation is installed in substantial contact with 0 0 0 the inside surface separating conditioned space from unconditional space. EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition {2017} -Energy Conservation ASHRAE 90.1-2013 -Energy Cost Budget Option 7/27/2020 Page 14 of24 Input Data Report Project Information Project Name: Seminole Rd Store Project Title: Seminole Rd Store Shell Address: 31 Seminole Road State: Florida Zip: 32233 Owner: Building Type: Retail No.of Stories: Building Classification: Renovation to existing building GrossArea (SF): 2,226 Bldg. Rotation: 2 Deg Clockwise. Walls & Windows will be rotated accordingly Zones No Acronym Description Type Area Multi Total Area [sf] [sf] I RTU-I RTU-I CONDITIONED 1358.0 I 1358.0 0 2 RTU-2 RTU-2 CONDITIONED 868.0 I 868.0 0 Spaces No Acronym Description Type Depth Width Height Mult Total Total [ft] [ft] [ft] Area Vol[cf] [sf] In Zone: RTU-l 1 Shell Shell Sales Area 10.00 131.00 10.00 1 1310.0 13100.00 2 Toilet Toilet Sales Area 10.00 4.80 9.00 1 In Zone: RTU-2 1 2 Shell Shell Sales Area 10.00 82.00 10.00 1 Toilet Toilet Sales Area 10.00 4.80 9.00 1 EnergyGauge Summit® FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASHRAE 90.1-2013 -Energy Cost Budget Option 48.0 820.0 48.0 7/27/2020 Page 17 of24 432.0 0 8200.0 0 432.0 0 Lighting No Type Category No. of Watts per Power Control Type Luminaires Luminaire [W] In Zone: RTU-l In Space: Shell 1 LED General Lighting 1 Manual On/Off In Space: Toilet LED General Lighting 50 50 Manual On/Off In Zone: RTU-2 In Space: Shell LED General Lighting 1 Manual On/Off In Space: Toilet LED General Lighting 50 50 Manual On/Off Walls (Walls will be rotated clockwise by building rotation value) No.of Ctrl pts 3 D D 3 D 1 D No Description Type Width H (Effec) Multi Area Orient Cond-Heat Dens. R-Value [ft] [ft] plier [sf] ation uctance Capacity [Ib/cf] [h.sf.FlBtu] rBtu/h.sf.Fl [Btu/sf.F] In Zone: RTU-l 1 East 8"CMU/3/4"ISO 35.00 12.00 420.0 East 0.2642 9.696 BTWN24"oc/5/8 Gyp 2 West 8"CMU/3/4"ISO 35.00 12.00 420.0 West 0.2642 9.696 BTWN24"oc/5/8 Gyp 3 North 8"CMU/3/4"ISO 39.00 12.00 468.0 North 0.2642 9.696 BTWN24"oc/5/8 Gyp In Zone: RTU-2 1 East 8"CMU/3/4"ISO 22.50 12.00 270.0 East 0.2642 9.696 BTWN24"oc/5/8 Gyp 2 South 8"CMU/3/4"ISO 39.00 12.00 468.0 South 0.2642 9.696 BTWN24"oc/5/8 Gyp 3 West 8"CMU/3/4"ISO 35.00 12.00 420.0 West 0.2642 9.696 BTWN24"oc/5/8 Gyp EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option 62.72 62.72 62.72 62.72 62.72 62.72 7/27/2020 Page 18 of24 3.8 0 3.8 0 3.8 0 3.8 0 3.8 0 3.8 0 ---~------------- Systems RTU-l RTU-l Constant Volume Packaged System Component Category Capacity Efficiency IPLV 1 Cooling System 62200.00 14.00 12.90 2 Heating System 35800.00 1.00 3 Air Handling System -Supply 2000.00 0.80 RTU-2 RTU-2 Constant Volume Packaged System Comeonent Category Capacity Efficiency IPLV 1 Cooling System 49200.00 14.00 14.00 2 Heating System 22200.00 1.00 3 Air Handling System -Supply 1600.00 0.80 Plant Equipment Category Size InstN<Eff. Water Heaters W-Heater Description Capacity Cap.Unit I1PRt. Efficiency 1 Electric water heater 1 [Gal] 3 [kW] 0.9700 [Et] EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option No. Of Units 1 D D D No. Of Units 1 D D D IPLV Loss [BtuIh] 0 7/2712020 Page 21 of24 Ext-Lighting Description Category No. of Watts per ArealLenlNo Control Wattage Lumin-Lumin-[sf/ftINo] Type [W] aires aire 1 Ext Light 1 Canopies (freestanding, 6 26 430.00 Photo Sensor contn 'f#### 0 attached and Overhangs) 2 Ext Light 2 Building facades (by linear 3 40 100.00 Photo Sensor contn 'f#### 0 foot) Piping Operating Insulation Nomonal pipe Insulation Is No Type Temp Conductivity Diameter Thickness Runout? [F] [ Btu-inlh.sf.F] [in] [in] 1 Domestic and Service Hot Water 110.00 0.28 0.25 1.00 Systems Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes [Btulh.sf.F] ASHULSgIClrAll User Defined 1 0.4500 0.8200 0.7600 Frm EnergyGauge Summit® FIa/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASHRAE 90.1-2013 -Energy Cost Budget Option 7127/2020 Page 22 of 24 No D Materials Used Mat No Acronym Description Only RValue Thick Cond-Density R-Value [h.sf.F /Btu] [ft] uctivity [Ib/ef] 187 178 265 48 105 269 11 248 Used [Btulb.ftF Matl187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 BOARD,1I2IN Matl178 CARPET WIRUBBER PAD Yes 1.2300 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 Matll05 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 HOLLOW Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 Matl11 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 SLAG1I2IN EnergyGauge Summit® FlaiCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option Sp. Heat [Btullb.F] 0.2000 0.2000 0.2000 0.2000 0.3000 0.2000 0.4000 7/27/2020 Page 23 of 24 0 0 0 D 0 0 0 0 "-------------.. No 1014 No 1045 No 1057 Constructs Used Name Simple Massless Conductance Heat Cap Density Construct Construct [Btulh.sf.F] [Btu/sf.F] [Ib/d] 8"CMU/3/4"ISO BTWN24"oc/5/8 No No 0.26 9.70 62.72 Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 105 CONC BLK HW, 8IN, HOLLOW 0.6667 0.000 2 269 .75" ISO BTWN24" oc 0.0625 0.000 3 187 GYP OR PLAS BOARD,1I2IN 0.0417 0.000 Name Simple Massless Conductance Heat Cap Density Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/d] Built-up GraveV2" ISOIMtl Deck No No 0.15 0.98 12.59 Layer Material Material Thickness Framing No. [ft] Factor 1 248 ROOF GRAVEL OR SLAG 1I2IN 0.0417 0.000 2 11 2 in. Insulation 0.1670 0.000 Name Simple Massless Conductance Heat Cap Density Construct Construct [Btu/h.sf.F] [Btu/sf. F) [lb/d] 1 ft. soil, concrete floor, carpet and No No 0.27 34.00 113.33 rubber pad Layer Material Material Thickness Framing No. [et] Factor 1 265 Soil, 1 ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET WIRUBBER PAD 0.000 EnergyGauge Summil® FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31,2017 Florida Building Code, Sixth Edition (2017) -Energy Conservation ASH RAE 90.1-2013 -Energy Cost Budget Option RValue [h.sf.FIBtu] 3.8 0 0 0 0 RValue [h.sf.FIBtu] 6.7 0 0 0 RValue [h.sf.FIBtu] 3.7 0 0 0 0 7/27/2020 Page 24 of24 1 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 6/11/2020 Permit #: COMM20-0009 Site Address: 31 XX Seminole Road Review: 1 RE#: Applicant: Building Dynamics Inc. Address: 33 Fairway Ln., Jax Bch. Phone: 813-4890 Email: BDIConstruction@att.net THIS BUILDING DEPARTMENT REVIEW IS ONE OF 2 DEPARTMENT REVIEWS. PLEASE FIND ALL DEPARTMENT REVIEWS AND ADDRESS ALL COMMENTS. Correction Comments: Application is disapproved for the following issues: 1. This preliminary submittal was sent to my email address, with plans only. The next submittal will be a revision to the original plan, changing from one space to two. Please go to http://coab.us/799/Building- Dept for information and instructions for uploading your submittal, including a completed Revision Form, enclosed here. 2. Please state the Method of Alteration, in the Code Analysis, per FBC-Existing Building, Section 301.1. The method chosen will correspond to a specific FBC-EB chapter. All provisions of that chapter will apply to this permit. Please review that chapter and provide the required details. 3. Per the Architect’s letter, this space will be a Business Occupancy. Project Data on plans states Mercantile. Please provide a Code Analysis with Mercantile Occupancy. 4. Please provide an approved design (UL or equivalent) for 1-hour fire-resistance rated separation wall, Detail 2/A-3. 5. If used as Mercantile, Hi-Low drinking fountain and service sink will be required. 6. New address numbers will be issued: 31-A and 31-B Seminole Road. 7. Two, independent HVAC and Electrical systems must be provided. Load calculations and Energy Sheets will be required. 8. The revised submittal will be forwarded to the Fire Marshal’s Office for review and may generate additional review comments. The Fire Marshal may require a Life Safety Plan and occupancy load calculations based on the Florida Fire Prevention Code (FPC). Dan Arlington, CBO (904) 247-5813 darlington@coab.us Design Affiliation Architecture 13015 Fort Caroline Road Jacksonville, Florida 32225 (904)476-0320 Thomas H. Perdue, NCARB perduedesign@gmail.com www.designaffiliation.com architecture │ a/e/c project management │ planning │ interior design June 19th, 2020 Mr. Dan Arlington Building Department 800 Seminole Rd. Atlantic Beach, Florida 32233 Reference: Existing Building at 31 Seminole Rd. Subject: Comments to Your Second Building Review Dear Mr. Arlington, First, I was surprised to be notified by the Owner of the Property, you had sent comments, to him and the General Contractor, since I was the Professional who had submitted the Revised Drawings and Letter to your office at the City of Atlantic Beach, Florida. Second, please find enclosed documents, (Drawings and Letter) addressing your comments dated 06/11/2020. Third, since there appears to be confusion to the process for this project, I guess I need to go back to the beginning of this Project, since I became involved, so you have a better understanding of where we a going. 1. From my experience of working on numerous of the old Jiffy Mart Stores in Jacksonville, they were not built cheaply and normally to construction Type 3B. A lot were built in the 1970's, as this was in 1979. They were built under Southern Building Code Requirements, of Tie Columns, Substantial Tie Beams, usually 16” deep and well tied to the foundation. A Steel Beam being located above the Storefront, sitting on Tie Columns. It is obvious, I cannot verify the exact design of the Structural Elements, as I do not have the June 19h, 2020 Mr. Dan Arlington City of Atlantic Beach, FL Page 2 of 4 Design Affiliation Architecture Jacksonville · Savannah (904)894-8329 daa@designaffiliation.com designaffiliation.com original Permit Plans. I am sure the City of Atlantic Beach Building Department can review these plans to verify what I have stated. 2. After King Food closed, the space was leased to the Tenant Salty Paws, which was located in a building behind the old King Food. This was when I was originally involved with the building. After a number of months the Salty Paws owner gave up their Lease and went out of business. 3. The Building Owner then requested that I design a typical "White Box" Plan for the space so he could find another Tenant. He gave me the following criteria; a. A single space designed to be divided into two spaces. b. It was to have two HVAC Units, so if, need be, it could be leased in two parts. c. The Original Permit Plans, which were submitted by the Owner's Contractor, Richard Farmer, was a complete set with Architectural, MEP and Energy Calculations. d. We set the use for the single space at Mercantile, since that was what it had been in the past, and not to put it at the minimum standard of "Business Use". This is how the Building Use was noted on the First Revised Drawings as Mercantile not Business, my fault. e. The only comments I received on the original submission, from the General Contractor, was related to the Toilet Layout, not meeting ADA, we discussed this issue. 4. Not long after this, I was notified by the Owner he had Leased part of the space, now shown on my first Revised Architectural Plans, recently submitted to the City, with the comments I now have. a. On the revised Architectural Plans I submitted to you, we went back to using one of the original Toilets from the King Food, using the Drain, the Vent, and the Floor Drain. Everything else was to be new. The Second Toilet Drain and Floor Drain, would be capped. b. The Toilet for the unleased space was to be a typical ADA Layout, and tied into the Existing Drain Line in the floor, see Floor Plan Drawing. It will be installed June 19h, 2020 Mr. Dan Arlington City of Atlantic Beach, FL Page 3 of 4 Design Affiliation Architecture Jacksonville · Savannah (904)894-8329 daa@designaffiliation.com designaffiliation.com with a future set of Permit Documents since we do not know what will be going into this space, and its requirements. c. The proposed Electrical Service on the Original Permit Plans, will be used for the newTenant, unless the Electrical Sub-contractor deems it to be to be excessive for this tenants needs. If so, he will revise it under his License. Currently there is an existing 400 amp service from the old King Food, to be removed. d. No Electrical Service will be installed in the second space, until a Tenant has Leased the Space. Tenant Improvement Plans will be submitted at that time. 5. Per my Plans, and my Letter submitted within, there ARE NO Major Revisions or alterations to the Existing Building Structure. We are making Minor Alterations for HVAC reinforcement on the Roof, and an addition of a new Entrance Door, in the Existing Storefront. As I do not have any information or plans on the original Building, I am not aware of any issues related to FBC 301.1, especially related to Seismic! I would be more concerned about Wind Loads, being the building is located east of the Intercoastal Waterway. The following revisions are being made on these Plans; a. Additional Minor Framing between the Existing Bar Joist for the New Roof HVAC Curb Support will be Installed, see MEP. This in no way alters the Original Structural Design for the Building Roof, only reinforces it where the New HVAC are to be located. b. The Storefront Subcontractor, will revise the existing Storefront System for the New Entrance Door to be added for the unleased space, and submit a "Means and Method Drawing". There is an Existing Steel Beam above the present Storefront System. It is what the Roof Bar Joist Sit on for the Existing Building (see added notes to my Drawings). I do not have the size, as I cannot get to it. It is part of the Original Design, and Is Not Being Altered! c. One Hour Wall Design has UL Design Number. d. Per last letter, the New Use is Business. e. Fire Exiting Drawing is now Provided, with the required Data. June 19h, 2020 Mr. Dan Arlington City of Atlantic Beach, FL Page 4 of 4 Design Affiliation Architecture Jacksonville · Savannah (904)894-8329 daa@designaffiliation.com designaffiliation.com 6. The General Contractor will provide a Revised Cost to accomplish the New Work on the Revised Architectural Plans, and this Signed and Sealed Letter on the Architect's Letterhead. Hopefully this letter and revised Drawings will clear up any issues, and a Renovation Permit can be issued to the General Contractor. Sincerely, Thomas H. Perdue NCARB Design Affiliation Architecture Enc: Copy of Submitted Energy Calculations Copy of Your Comments, Dated 06/11/2020 Revised Architectural Drawings Permit Number: COMM20-0009 Site Address: 31 SEMINOLE RD City, State Zip Code: Atlantic Beach, Fl 32233 Applied: 3/20/2020 Approved: Issued: Parent Permit: Parent Project: Applicant: <NONE> Owner: SOLOMON PROPERTIES INC Contractor: <NONE> Description: INTERIOR BUILDOUT - WHITE BOX Finaled: Status: RECEIVED Details: LIST OF REVIEWS SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: 2ND REVIEW 7/1/2020 7/1/2020 SUBMITTAL COMPLETENESS Jennifer Johnston APPROVED Notes: received 2nd submittal via email, uploaded as 8 attachments, routed to CBO for Bldg. plan review ADDED REVISION SHEET 7/1/2020 7/6/2020 7/12/2020 BUILDING Dan Arlington DENIED Notes: See attached comments. Review Group: 3RD REVIEW 8/10/2020 8/10/2020 SUBMITTAL COMPLETENESS Jennifer Johnston APPROVED Notes: received 3rd submittal via FTP site, uploaded as 6 attachments - new architect & change in project value 8/10/2020 8/12/2020 8/24/2020 BUILDING Building APPROVED Job Copy attached Notes: Printed: Wednesday, 23 September, 2020 1 of 2 Permit Reviews City of Atlantic Beach 8/10/2020 9/23/2020 8/24/2020 FIRE Fire DENIED Notes: denied via email by Miguel DiPierri, JFRD: NOT APPROVED Returned for Corrections: The plans submitted for review have been returned for corrections. Please correct and or provide the additional requested information to obtain plans approval. When resubmitting corrected sheets, provide a type written itemized narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER “WILL” RESULT IN A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded, clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission please make sure that written narrative is submitted under correspondence along with a “complete set” (not just the revised sheets) of electronic documents. When submitting electronic plans, each discipline shall upload a single PDF file containing multiple sheets rather than separate PDFs for each sheet. Please re-upload in this fashion. Key Plan: Provide key plan of building showing adjacent occupancy type with required separation of occupancies per 6th Edition FFPC, NFPA 101 Table 6.1.14.1.4. (MERCANTILE TO BUS ) REQ 2 HR WALL NEED TO SHOW RATING Required Lightweight Truss Signage: • Location of lightweight truss signage per FAC 69A-60.0081 (if applicable). Please see below for clarification to requirement. http://www.coj.net/Departments/Planning-and-Development/Docs/Building-Inspection-Division/bulletin-f-01-09-light-weight-truss-rule.aspx Review Group: ALL 6/11/2020 6/11/2020 6/11/2020 BUILDING Dan Arlington DENIED Notes: See attached comments. Review Group: AUTO 3/20/2020 3/20/2020 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: 3/20/2020 6/11/2020 4/3/2020 BUILDING Building DENIED Notes: Waiting for new floor plan revision. 3/20/2020 6/11/2020 4/3/2020 FIRE Fire DENIED Notes: Changed one space to two. Waiting for revised plans. Printed: Wednesday, 23 September, 2020 2 of 2 Permit Reviews City of Atlantic Beach 1 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 6/11/2020, 7/06/2020 Permit #: COMM20-0009 Site Address: 31 XX Seminole Road Review: 1, 2 RE#: Applicant: Building Dynamics Inc. Address: 33 Fairway Ln., Jax Bch. Phone: 813-4890 Email: BDIConstruction@att.net THIS BUILDING DEPARTMENT REVIEW IS ONE OF 2 DEPARTMENT REVIEWS. PLEASE FIND ALL DEPARTMENT REVIEWS AND ADDRESS ALL COMMENTS. Correction Comments: Application is disapproved for the following issues: 1. This preliminary submittal was sent to my email address, with plans only. The next submittal will be a revision to the original plan, changing from one space to two. Please go to http://coab.us/799/Building- Dept for information and instructions for uploading your submittal, including a completed Revision Form, enclosed here. 2nd Review: Resubmittal package was not submitted as directed above. Permit staff uploaded package and forwarded to Fire Marshal for review. Resubmittal packages must be submitted as described above to be processed. 2. Please state the Method of Alteration, in the Code Analysis, per FBC-Existing Building, Section 301.1. The method chosen will correspond to a specific FBC-EB chapter. All provisions of that chapter will apply to this permit. Please review that chapter and provide the required details. 2nd Review: Method of Alteration not provided. Architect’s letter indicates his review of FBC-B 301.1. The above reference is FBC-Existing Building 301.1. All existing buildings start design and review with Existing Building Code. Please review and respond accordingly. 3. Per the Architect’s letter, this space will be a Business Occupancy. Project Data on plans states Mercantile. Please provide a Code Analysis with Mercantile Business Occupancy. Complete. 4. Please provide an approved design (UL or equivalent) for 1-hour fire-resistance rated separation wall, Detail 2/A-3. 5. If used as Mercantile, Hi-Low drinking fountain and service sink will be required. 6. New address numbers will be issued: 31-A and 31-B Seminole Road. 2 7. Two, independent HVAC and Electrical systems must be provided. Load calculations and Energy Sheets will be required. 2nd Review: Mechanical and Electrical pages were not provided. Please provide with all requested details. Electrical systems must be separated at this time and new addresses will be assigned to meters. 8. The revised submittal will be forwarded to the Fire Marshal’s Office for review and may generate additional review comments. The Fire Marshal may require a Life Safety Plan and occupancy load calculations based on the Florida Fire Prevention Code (FPC). 2nd Review: Sent to Fire Marshals’ Office for 2nd Review. Dan Arlington, CBO (904) 247-5813 darlington@coab.us APPROVED MIGUEL Di PIERRI Fire Safety Inspector / Plan Reviewer Hispanic Advocate, MHAAB JFRD PREVENTION OFFICE 214 HOGAN UNIT 281 St., Jacksonville, Florida 32202 Office: 904-255-8561 cell: 904-763-1290 – Email: DIPIERRI@COJ.NET From: csommers@dsae.net [mailto:csommers@dsae.net] Sent: Wednesday, September 23, 2020 3:04 PM To: 'Richard Farmer'; Dipierri, Miguel Cc: Padgett, Hardy Subject: RE: 31 Seminole Road EXTERNAL EMAIL: This email originated from a non-COJ email address. Do not click any links or open any attachments unless you trust the sender and know the content is safe. Mr. Di Pierri, Attached are the site plans for this property. The building we are remodeling and the adjacent building are about 6,600 sf, less than 10,000 sf. https://paopropertysearch.coj.net/Basic/Detail.aspx?RE=1706560000 Regarding the fire separation, the footnote at the bottom of table 6.1.14.4.1 (a & b) has an exception for buildings that are mercantile and business and are less than 10,000 sf. It says no separation is required. The adjacent building has 4 tenants: Beauty Spot Salon (B); Ceviche Jax (B) restaurant with less than 50 seats; Paula Drake Dean Insurance (B); and Art of Cigars (M). https://www.google.com/maps/@30.3249169,- 81.4058548,3a,15y,113.12h,90.22t/data=!3m7!1e1!3m5!1sSjkeCxUZ- JrNHnfQ0FnjRA!2e0!6s%2F%2Fgeo0.ggpht.com%2Fcbk%3Fpanoid%3DSjkeCxUZ- JrNHnfQ0FnjRA%26output%3Dthumbnail%26cb_client%3Dmaps_sv.tactile.gps%26thumb%3D2%26w%3 D203%26h%3D100%26yaw%3D95.16993%26pitch%3D0%26thumbfov%3D100!7i16384!8i8192 I think the footnote exception should eliminate the requirement for the two hour fire rated tenant separation wall. Let me know your thoughts. The footnote is noted on my code data sheet G-1. Thanks, Craig Sommers, AIA 370 15th Ave South Jacksonville Beach, FL 32250 904/249-0698 904/241-0691 fax AA26000952/AR0016480 Cert. of Auth 00009393 https://dsae.net/ From: Richard Farmer <richard@bdiconstruct.com> Sent: Tuesday, September 22, 2020 4:42 PM To: csommers@dsae.net Subject: FW: 31 Seminole Road From: Dipierri, Miguel [mailto:DiPierri@coj.net] Sent: Tuesday, September 22, 2020 4:10 PM To: JJohnston@coab.us; 'richard@bdiconstruct.com' Subject: FW: 31 Seminole Road NOT APPROVED Returned for Corrections: The plans submitted for review have been returned for corrections. Please correct and or provide the additional requested information to obtain plans approval. When resubmitting corrected sheets, provide a type written itemized narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER “WILL” RESULT IN A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded, clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission please make sure that written narrative is submitted under correspondence along with a “complete set” (not just the revised sheets) of electronic documents. When submitting electronic plans, each discipline shall upload a single PDF file containing multiple sheets rather than separate PDFs for each sheet. Please re-upload in this fashion. Key Plan: Provide key plan of building showing adjacent occupancy type with required separation of occupancies per 6th Edition FFPC, NFPA 101 Table 6.1.14.1.4. (MERCANTILE TO BUS ) REQ 2 HR WALL NEED TO SHOW RATING Required Lightweight Truss Signage: • Location of lightweight truss signage per FAC 69A-60.0081 (if applicable). Please see below for clarification to requirement. http://www.coj.net/Departments/Planning-and-Development/Docs/Building-Inspection-Division/bulletin-f- 01-09-light-weight-truss-rule.aspx MIGUEL Di PIERRI Fire Safety Inspector / Plan Reviewer Hispanic Advocate, MHAAB JFRD PREVENTION OFFICE 214 HOGAN UNIT 281 St., Jacksonville, Florida 32202 Office: 904-255-8561 cell: 904-763-1290 – Email: DIPIERRI@COJ.NET From: Padgett, Hardy Sent: Tuesday, September 22, 2020 8:48 AM To: Richard Farmer Cc: Dipierri, Miguel Subject: RE: 31 Seminole Road Hello Sir I have forwarded your inquiry to Inspector Dipierri Hardy From: Richard Farmer <richard@bdiconstructcom> Sent: Monday, September 21, 2020 4:33 PM To: Padgett, Hardy <HPadgett@coj.net> Subject: 31 Seminole Road EXTERNAL EMAIL: This email originated from a non-COJ email address. Do not click any links or open any attachments unless you trust the sender and know the content is safe. Hardy, Here are the drawings for 31 Seminole Road in Atlantic Beach. Please confirm receipt. Thank you, Richard Farmer Building Dynamics, Inc CBC1250884 Ph #: (904) 813-4890 Fax #: (904) 241-9206 E-Mail: richard@bdiconstruct.com