1545 MAIN ST ROW20-0028 812565_9JK0554B_SA
tnxTower Report - version 8.0.7.4
Date: August 04, 2020
Stephanie Lipscomb Paul J. Ford and Company
Crown Castle 250 E. Broad St., Ste 600
370 Mallory Station Rd Columbus, OH 43215
Franklin, TN 37067 614-221-6679
Subject: Structural Analysis Report
Carrier Designation: T-Mobile Co-Locate
Carrier Site Number: 9JK0554B
Carrier Site Name: ATLANTIC BEACH
Crown Castle Designation: Crown Castle BU Number: 812565
Crown Castle Site Name: MAYPORT
Crown Castle JDE Job Number: 616092
Crown Castle Work Order Number: 1874352
Crown Castle Order Number: 525878 Rev. 0
Engineering Firm Designation: Paul J. Ford and Company Project Number: 37520-0618.003.8700
Site Data: 1545 Main Street, Atlantic Beach, Duval County, FL
Latitude 30° 20' 13'', Longitude -81° 25' 12''
190 Foot - Self Support Tower
Dear Stephanie Lipscomb,
Paul J. Ford and Company is pleased to submit this “Structural Analysis Report” to determine the structural
integrity of the above mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC5: Proposed Equipment Configuration Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 129 mph as required by the 2017 Florida Building
Code, 6th Edition. Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria.
Respectfully submitted by:
Sara Mansoori
Structural Designer
smansoori@pauljford.com
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 2
tnxTower Report - version 8.0.7.4
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Equipment Configuration
Table 2 - Other Considered Equipment
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Table 5 – Tower Component Stresses vs. Capacity – LC5
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Base Level Drawing
7) APPENDIX C
Additional Calculations
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 3
tnxTower Report - version 8.0.7.4
1) INTRODUCTION
This tower is a 190 ft Self Support tower designed by ROHN in November of 1990.
The tower has been modified per reinforcement drawings prepared by PJF in July of 2011. Reinforcement
consist of replacing diagonals, redundant diagonals and adding half sleeves to existing diagonals.
2) ANALYSIS CRITERIA
TIA-222 Revision: TIA-222-H
Risk Category: II
Wind Speed: 129 mph
Exposure Category: C
Topographic Factor: 1
Ice Thickness: 0 in
Wind Speed with Ice: 30 mph
Service Wind Speed: 60 mph
Table 1 - Proposed Equipment Configuration
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
131.0 131.0
3 tower mounts C10857001C V-Boom
8
3
1
1
1-5/8
1-3/5
1-1/2
1-1/4
3 commscope FFHH-65C-R3_T-MOBILE
w/ Mount Pipe
1 commscope HCS 2.0
3 nokia AEHC w/ Mount Pipe
3 nokia AHFIG
3 nokia AHLOA_T-MOBILE
3 raycap RNSDC-7771-PF-48
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 4
tnxTower Report - version 8.0.7.4
Table 2 - Other Considered Equipment
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
187.0
190.0
3 andrew DBXNH-6565B-R2M w/
Mount Pipe
12
6
3
3
1-5/8
3/4
3/8
5/16
6 andrew SBNHH-1D65B w/ Mount
Pipe
3 commscope NNHH-65B-R4 w/ Mount
Pipe
3 ericsson RRUS 4449 B5/B12
3 ericsson RRUS 4478 B14
187.0
6 tower mounts 1.9" OD sched. 40 Pipe
6 andrew E15S09P78
2 commscope WCS-IMFQ-AMT-43
3 ericsson RRUS 32
3 ericsson RRUS 32 B2
3 ericsson RRUS 32 B66
6 raycap DC2-48-60-0-9E
1 raycap DC6-48-60-18-8C
2 raycap DC6-48-60-18-8F
1 tower mounts Sector Mount [SM 504-3]
178.0
184.0 1 andrew VHLP2-11
3
3
1
1-3/16
1/2
7/8
conduit
183.0 2 andrew VHLP2-18
178.0
3 tower mounts Connect-it PVFM-12-3-4-
96
3 dragonwave Horizon DUO
3 ericsson RRUS 31 B25
3 ericsson RRUS 82 W/SOLAR
SHIELD
6 ericsson RRUS-11 800MHz
3 kmw
communications
ETCR-654L12H6 w/
Mount Pipe
3 nokia RADAR FILTER
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
Document Remarks Reference Source
4-GEOTECHNICAL REPORTS ATEC, 12/03/1990 111139 CCISITES
4-TOWER FOUNDATION
DRAWINGS/DESIGN/SPECS Rohn, 04/07/1993 816089 CCISITES
4-TOWER MANUFACTURER
DRAWINGS Rohn, 11/06/1990 225932 CCISITES
4-TOWER REINFORCEMENT
DESIGN/DRAWINGS/DATA PJF, 07/05/2011 3009343 CCISITES
4-POST-MODIFICATION
INSPECTION TEP, 01/12/2012 3062154 CCISITES
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 5
tnxTower Report - version 8.0.7.4
3.1) Analysis Method
tnxTower (version 8.0.7.4), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has
calculated and provided the effective area for panel antennas using approved methods following the
intent of the TIA-222 Standard.
tnxTower was used to determine the loads on the modified structure. Additional calculations were
performed to determine the stresses in the reinforced sections. These calculations are presented in
Appendix C.
3.2) Assumptions
1) Tower and structures were maintained in accordance with the TIA-222 Standard.
2) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
This analysis may be affected if any assumptions are not valid or have been made in error. Paul J.
Ford and Company should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow
(K) %
Capacity Pass / Fail
T1 190 - 180 Leg Pipe 2.875" x 0.276" (2.5
XS) 3 -4.34 78.23 5.5 Pass
T2 180 - 160 Leg Pipe 3.5" x 0.300" (3 XS) 29 -30.61 99.18 30.9 Pass
T3 160 - 140 Leg Pipe 4.5" x 0.337" (4 XS) 67 -61.88 167.90 36.9 Pass
T4 140 - 120 Leg Pipe 5.563" x 0.375" (5
XS) 106 -92.29 251.35 36.7 Pass
T5 120 - 100 Leg Pipe 6.625" x 0.340" (6
EHS) 145 -119.10 256.22 46.5 Pass
T6 100 - 80 Leg Pipe 6.625" x 0.432" (6
XS) 172 -148.45 318.80 46.6 Pass
T7 80 - 60 Leg Pipe 6.625" x 0.432" (6
XS) 199 -175.36 318.76 55.0 Pass
T8 60 - 40 Leg Pipe 8.625" x 0.375" (8
EHS) 226 -201.68 405.62 49.7 Pass
T9 40 - 20 Leg Pipe 8.625" x 0.375" (8
EHS) 253 -228.38 405.62 56.3 Pass
T10 20 - 0 Leg Pipe 8.625" x 0.500" (8
XS) 280 -241.00 530.71 45.4 Pass
T1 190 - 180 Diagonal Pipe 2.375" x 0.154" (2
STD) 11 -3.87 25.36 15.2 Pass
T2 180 - 160 Diagonal Pipe 2.375" x 0.218" (2
XS) 32 -8.66 24.29 35.6 Pass
T3 160 - 140 Diagonal Pipe 2.375" x 0.154" (2
STD) 71 -7.70 16.10 47.8 Pass
T4 140 - 120 Diagonal Pipe 2.375" x 0.154" (2
STD) 110 -9.44 13.83 68.3 Pass
T5 120 - 100 Diagonal Pipe 2.875" x 0.203" (2.5
STD) 149 -11.70 17.33 67.5 Pass
T6 100 - 80 Diagonal Pipe 3.5" x 0.216" (3 STD) 176 -11.27 29.92 37.6 Pass
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 6
tnxTower Report - version 8.0.7.4
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow
(K) %
Capacity Pass / Fail
T7 80 - 60 Diagonal Pipe 3.5" x 0.216" (3 STD) 203 -11.24 26.02 43.2 Pass
T8 60 - 40 Diagonal Pipe 3.5" x 0.216" (3 STD) 230 -12.15 23.18 52.4 Pass
T9 40 - 20 Diagonal Pipe 3.5" x 0.216" (3 STD) 257 -12.51 20.36 61.4 Pass
T10 20 - 0 Diagonal (37515-2715) 2.875" x
.276" Pipe w/ 3.5" x .300"
Half Sleeve 284 -19.12 31.19 58.6 Pass
T1 190 - 180 Horizontal Pipe 1.9" x 0.145" (1.5
STD) 10 -2.69 23.71 11.4 Pass
T2 180 - 160 Horizontal Pipe 1.9" x 0.145" (1.5
STD) 31 -4.64 23.65 19.6 Pass
T3 160 - 140 Horizontal Pipe 1.9" x 0.145" (1.5
STD) 70 -4.89 20.10 24.3 Pass
T4 140 - 120 Horizontal Pipe 2.375" x 0.154" (2
STD) 109 -6.72 28.57 23.5 Pass
T5 120 - 100 Horizontal Pipe 2.375" x 0.154" (2
STD) 148 -7.16 23.77 30.1 Pass
T6 100 - 80 Horizontal Pipe 2.375" x 0.154" (2
STD) 175 -7.48 17.71 42.2 Pass
T7 80 - 60 Horizontal Pipe 2.875" x 0.203" (2.5
STD) 202 -7.95 30.07 26.4
27.5 (b) Pass
T8 60 - 40 Horizontal Pipe 2.875" x 0.203" (2.5
STD) 229 -9.01 23.50 38.3 Pass
T9 40 - 20 Horizontal Pipe 2.875" x 0.203" (2.5
STD) 256 -9.39 18.71 50.2 Pass
T10 20 - 0 Horizontal Pipe 2.875" x 0.203" (2.5
STD) 283 -10.56 16.85 62.7 Pass
T1 190 - 180 Top Girt Pipe 1.9" x 0.145" (1.5
STD) 5 -0.78 23.77 3.3 Pass
T10 20 - 0 Redund Horz 1
Bracing Pipe 1.9" x 0.145" (1.5
STD) 285 -4.18 13.53 30.9 Pass
T10 20 - 0 Redund Diag 1
Bracing Pipe 2.375" x 0.154" (2
STD) 305 -3.82 9.45 40.5 Pass
T10 20 - 0 Redund Hip 1
Bracing Pipe 1.9" x 0.145" (1.5
STD) 308 -0.03 12.45 0.2 Pass
T10 20 - 0 Redund Hip
Diagonal 1
Bracing
Pipe 2.875" x 0.203" (2.5
STD) 298 -0.06 11.09 0.6 Pass
T1 190 - 180 Inner Bracing L 2 x 2 x 1/8 25 -0.01 8.84 0.2 Pass
T2 180 - 160 Inner Bracing L 2 x 2 x 1/8 41 -0.00 8.65 0.1 Pass
T3 160 - 140 Inner Bracing L 2 x 2 x 1/8 81 -0.00 6.37 0.1 Pass
T4 140 - 120 Inner Bracing L 2 x 2 x 1/8 120 -0.01 4.37 0.2 Pass
T5 120 - 100 Inner Bracing L 2 x 2 x 1/8 159 -0.01 3.30 0.2 Pass
T6 100 - 80 Inner Bracing L 2.5 x 2.5 x 3/16 186 -0.01 6.95 0.2 Pass
T7 80 - 60 Inner Bracing L 3 x 3 x 3/16 213 -0.01 9.09 0.1 Pass
T8 60 - 40 Inner Bracing L 3.5 x 3.5 x 1/4 240 -0.01 14.80 0.2 Pass
T9 40 - 20 Inner Bracing L 3.5 x 3.5 x 1/4 267 -0.01 11.87 0.2 Pass
T10 20 - 0 Inner Bracing Pipe 2.375" x 0.154" (2
STD) 312 -0.01 6.92 0.3 Pass
Summary
Leg (T9) 56.3 Pass
Diagonal
(T4) 68.3 Pass
Horizontal
(T10) 62.7 Pass
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 7
tnxTower Report - version 8.0.7.4
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow
(K) %
Capacity Pass / Fail
Top Girt
(T1) 3.3 Pass
Redund
Horz 1
Bracing
(T10)
30.9 Pass
Redund
Diag 1
Bracing
(T10)
40.5 Pass
Redund Hip
1 Bracing
(T10) 0.2 Pass
Redund Hip
Diagonal 1
Bracing
(T10)
0.6 Pass
Inner
Bracing
(T10) 0.3 Pass
Bolt Checks 44.0 Pass
Rating = 68.3 Pass
Table 5 - Tower Component Stresses vs. Capacity – LC5
Notes Component Elevation (ft) % Capacity Pass / Fail
1 Anchor Rods - 16.7 Pass
1 Base Foundation
Structural - 8.8 Pass
1 Base Foundation
Soil Interaction - 46.5 Pass
Structure Rating (max from all components) = 68.3%
Notes:
• All structural ratings are per TIA-222-H Section 15.5
1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity
consumed.
4.1) Recommendations
The tower and its foundation have sufficient capacity to carry the proposed load configuration. No
modifications are required at this time.
Paul J. Ford and Company
250 E. Broad St., Ste 600
Columbus, OH 43215
Phone: 614-221-6679
FAX:
Job: 190-ft Self Support Tower Atlantic Beach, FL
Project: PJF# 37520-0618.003.8700 (BU# 812565)
Client: Crown Castle Drawn by: Sara Mansoori App'd:
Code: TIA-222-H Date: 08/04/20 Scale: NTS
Path:
G:\TOWER\375_Crown_Castle\2020\37520-0618_812565_MAYPORT\37520-0618.003.8700_SA_1874352\37520-0618.003.8700.eri
Dwg No. E-1
190.0 ft
180.0 ft
160.0 ft
140.0 ft
120.0 ft
100.0 ft
80.0 ft
60.0 ft
40.0 ft
20.0 ft
0.0 ft
REACTIONS - 129 mph WIND
TORQUE 147 kip-ft
55 K
SHEAR
5968 kip-ft
MOMENT
62 K
AXIAL
SHEAR: 30 K
UPLIFT: -233 K
SHEAR: 33 K
DOWN: 266 K
MAX. CORNER REACTIONS AT BASE:
ARE FACTORED
ALL REACTIONS
S
e
c
t
i
o
n
T1
T2
T3
T4
T5
T6
T7
T8
T9
T1
0
L
e
g
s
A
Pi
p
e
3
.
5
"
x
0
.
3
0
0
"
(
3
X
S
)
Pi
p
e
4
.
5
"
x
0
.
3
3
7
"
(
4
X
S
)
B
C
Pi
p
e
6
.
6
2
5
"
x
0
.
4
3
2
"
(
6
X
S
)
Pi
p
e
8
.
6
2
5
"
x
0
.
3
7
5
"
(
8
E
H
S
)
D
L
e
g
G
r
a
d
e
A6
1
8
-
5
0
D
i
a
g
o
n
a
l
s
E
F
Pi
p
e
2
.
3
7
5
"
x
0
.
1
5
4
"
(
2
S
T
D
)
G
Pi
p
e
3
.
5
"
x
0
.
2
1
6
"
(
3
S
T
D
)
H
D
i
a
g
o
n
a
l
G
r
a
d
e
A6
1
8
-
5
0
A5
3
-
B
-
3
5
T
o
p
G
i
r
t
s
I
N.
A
.
H
o
r
i
z
o
n
t
a
l
s
Pi
p
e
1
.
9
"
x
0
.
1
4
5
"
(
1
.
5
S
T
D
)
Pi
p
e
2
.
3
7
5
"
x
0
.
1
5
4
"
(
2
S
T
D
)
Pi
p
e
2
.
8
7
5
"
x
0
.
2
0
3
"
(
2
.
5
S
T
D
)
R
e
d
.
H
o
r
i
z
o
n
t
a
l
s
N.
A
.
I
R
e
d
.
D
i
a
g
o
n
a
l
s
N.
A
.
E
R
e
d
.
H
i
p
s
N.
A
.
I
I
n
n
e
r
B
r
a
c
i
n
g
L
2
x
2
x
1
/
8
L
2
.
5
x
2
.
5
x
3
/
1
6
L
3
x
3
x
3
/
1
6
L
3
.
5
x
3
.
5
x
1
/
4
E
F
a
c
e
W
i
d
t
h
(
f
t
)
8.
5
8.
5
4
1
6
7
8.
6
2
5
10
.
7
0
8
3
12
.
7
9
1
7
15
.
0
4
1
7
17
.
5
4
1
7
20
.
1
7
7
1
22
.
6
7
7
1
25
.
1
7
7
1
27
.
6
7
7
1
#
P
a
n
e
l
s
@
(
f
t
)
2
@
5
9
@
6
.
6
6
6
6
7
10
@
1
0
1
@
2
0
W
e
i
g
h
t
(
K
)
0.
8
1.
8
1.
9
2.
5
2.
9
3.
7
4.
2
4.
9
5.
1
6.
3
34
.
1
SYMBOL LIST
MARK MARKSIZE SIZE
A Pipe 2.875" x 0.276" (2.5 XS)
B Pipe 5.563" x 0.375" (5 XS)
C Pipe 6.625" x 0.340" (6 EHS)
D Pipe 8.625" x 0.500" (8 XS)
E Pipe 2.375" x 0.154" (2 STD)
F Pipe 2.375" x 0.218" (2 XS)
G Pipe 2.875" x 0.203" (2.5 STD)
H (37515-2715) 2.875" x .276" Pipe w/ 3.5" x .300"
Half Sleeve
I Pipe 1.9" x 0.145" (1.5 STD)
MATERIAL STRENGTH
GRADE GRADEFy FyFu Fu
A618-50 50 ksi 70 ksi A53-B-35 35 ksi 60 ksi
TOWER DESIGN NOTES
1. Tower is located in Duval County, Florida.
2. Tower designed for Exposure C to the TIA-222-H Standard.
3. Tower designed for a 129 mph basic wind in accordance with the TIA-222-H Standard.
4. Deflections are based upon a 60 mph wind.
5. Tower Risk Category II.
6. Topographic Category 1 with Crest Height of 0.00 ft
7. TIA-222-H Annex S
8. TOWER RATING: 68.3%
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 8
tnxTower Report - version 8.0.7.4
APPENDIX A
TNXTOWER OUTPUT
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 9
tnxTower Report - version 8.0.7.4
Tower Input Data
The main tower is a 3x free standing tower with an overall height of 190.00 ft above the ground line.
The base of the tower is set at an elevation of 0.00 ft above the ground line.
The face width of the tower is 8.50 ft at the top and 27.68 ft at the base.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
3) Tower is located in Duval County, Florida.
4) Tower base elevation above sea level: 12.00 ft.
5) Basic wind speed of 129 mph.
6) Risk Category II.
7) Exposure Category C.
8) Simplified Topographic Factor Procedure for wind speed-up calculations is used.
9) Topographic Category: 1.
10) Crest Height: 0.00 ft.
11) Deflections calculated using a wind speed of 60 mph.
12) TIA-222-H Annex S.
13) Pressures are calculated at each section.
14) Tower analysis based on target reliabilities in accordance with Annex S.
15) Load Modification Factors used: Kes(Fw) = 0.95.
16) Stress ratio used in tower member design is 1.05.
17) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are
not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules
Consider Moments - Horizontals Assume Legs Pinned √ Calculate Redundant Bracing Forces
Consider Moments - Diagonals Assume Rigid Index Plate Ignore Redundant Members in FEA
Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
Use Code Stress Ratios √ Use Clear Spans For KL/r All Leg Panels Have Same Allowable
√ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation
Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque
Always Use Max Kz √ Use Azimuth Dish Coefficients √ Include Angle Block Shear Check
Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.
Exemption
√ Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice
Exemption
Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles
√ Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Include Shear-Torsion Interaction
Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow
SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets
SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments
Pole With Shroud Or No
Appurtenances
Outside and Inside Corner Radii Are
Known
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 10
tnxTower Report - version 8.0.7.4
Leg B Leg C
Leg A
F a c e A F
a
c
e
B
Face C
Triangular Tower
Wind Normal
Wind 90
Wind 180
Z
X
Tower Section Geometry
Tower
Section
Tower
Elevation
ft
Assembly
Database
Description Section
Width
ft
Number
of
Sections
Section
Length
ft
T1 190.00-180.00 8.50 1 10.00
T2 180.00-160.00 8.54 1 20.00
T3 160.00-140.00 8.63 1 20.00
T4 140.00-120.00 10.71 1 20.00
T5 120.00-100.00 12.79 1 20.00
T6 100.00-80.00 15.04 1 20.00
T7 80.00-60.00 17.54 1 20.00
T8 60.00-40.00 20.18 1 20.00
T9 40.00-20.00 22.68 1 20.00
T10 20.00-0.00 25.18 1 20.00
Tower Section Geometry (cont’d)
Tower
Section
Tower
Elevation
ft
Diagonal
Spacing
ft
Bracing
Type
Has
K Brace
End
Panels
Has
Horizontals
Top Girt
Offset
in
Bottom Girt
Offset
in
T1 190.00-180.00 5.00 K Brace Down No Yes 0.0000 0.0000
T2 180.00-160.00 6.67 K Brace Down No Yes 0.0000 0.0000
T3 160.00-140.00 6.67 K Brace Down No Yes 0.0000 0.0000
T4 140.00-120.00 6.67 K Brace Down No Yes 0.0000 0.0000
T5 120.00-100.00 10.00 K Brace Down No Yes 0.0000 0.0000
T6 100.00-80.00 10.00 K Brace Down No Yes 0.0000 0.0000
T7 80.00-60.00 10.00 K Brace Down No Yes 0.0000 0.0000
T8 60.00-40.00 10.00 K Brace Down No Yes 0.0000 0.0000
T9 40.00-20.00 10.00 K Brace Down No Yes 0.0000 0.0000
T10 20.00-0.00 20.00 K1 Down No Yes 0.0000 0.0000
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 11
tnxTower Report - version 8.0.7.4
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Leg
Type
Leg
Size
Leg
Grade
Diagonal
Type
Diagonal
Size
Diagonal
Grade
T1 190.00-
180.00
Pipe Pipe 2.875'' x 0.276'' (2.5
XS)
A618-50
(50 ksi)
Pipe Pipe 2.375'' x 0.154'' (2
STD)
A618-50
(50 ksi)
T2 180.00-
160.00
Pipe Pipe 3.5'' x 0.300'' (3 XS) A618-50
(50 ksi)
Pipe Pipe 2.375'' x 0.218'' (2 XS) A618-50
(50 ksi)
T3 160.00-
140.00
Pipe Pipe 4.5'' x 0.337'' (4 XS) A618-50
(50 ksi)
Pipe Pipe 2.375'' x 0.154'' (2
STD)
A618-50
(50 ksi)
T4 140.00-
120.00
Pipe Pipe 5.563'' x 0.375'' (5 XS) A618-50
(50 ksi)
Pipe Pipe 2.375'' x 0.154'' (2
STD)
A618-50
(50 ksi)
T5 120.00-
100.00
Pipe Pipe 6.625'' x 0.340'' (6
EHS)
A618-50
(50 ksi)
Pipe Pipe 2.875'' x 0.203'' (2.5
STD)
A618-50
(50 ksi)
T6 100.00-
80.00
Pipe Pipe 6.625'' x 0.432'' (6 XS) A618-50
(50 ksi)
Pipe Pipe 3.5'' x 0.216'' (3 STD) A618-50
(50 ksi)
T7 80.00-60.00 Pipe Pipe 6.625'' x 0.432'' (6 XS) A618-50
(50 ksi)
Pipe Pipe 3.5'' x 0.216'' (3 STD) A618-50
(50 ksi)
T8 60.00-40.00 Pipe Pipe 8.625'' x 0.375'' (8
EHS)
A618-50
(50 ksi)
Pipe Pipe 3.5'' x 0.216'' (3 STD) A618-50
(50 ksi)
T9 40.00-20.00 Pipe Pipe 8.625'' x 0.375'' (8
EHS)
A618-50
(50 ksi)
Pipe Pipe 3.5'' x 0.216'' (3 STD) A618-50
(50 ksi)
T10 20.00-0.00 Pipe Pipe 8.625'' x 0.500'' (8 XS) A618-50
(50 ksi)
Arbitrary
Shape
(37515-2715) 2.875'' x .276''
Pipe w/ 3.5'' x .300'' Half
Sleeve
A53-B-35
(35 ksi)
Tower Section Geometry (cont’d)
Tower
Elevation
ft
No.
of
Mid
Girts
Mid Girt
Type
Mid Girt
Size
Mid Girt
Grade
Horizontal
Type
Horizontal
Size
Horizontal
Grade
T1 190.00-
180.00
None Flat Bar A36
(36 ksi)
Pipe Pipe 1.9'' x 0.145''
(1.5 STD)
A618-50
(50 ksi)
T2 180.00-
160.00
None Flat Bar A36
(36 ksi)
Pipe Pipe 1.9'' x 0.145''
(1.5 STD)
A618-50
(50 ksi)
T3 160.00-
140.00
None Flat Bar A36
(36 ksi)
Pipe Pipe 1.9'' x 0.145''
(1.5 STD)
A618-50
(50 ksi)
T4 140.00-
120.00
None Flat Bar A36
(36 ksi)
Pipe Pipe 2.375'' x 0.154''
(2 STD)
A618-50
(50 ksi)
T5 120.00-
100.00
None Flat Bar A36
(36 ksi)
Pipe Pipe 2.375'' x 0.154''
(2 STD)
A618-50
(50 ksi)
T6 100.00-
80.00
None Flat Bar A36
(36 ksi)
Pipe Pipe 2.375'' x 0.154''
(2 STD)
A618-50
(50 ksi)
T7 80.00-60.00 None Flat Bar A36
(36 ksi)
Pipe Pipe 2.875'' x 0.203''
(2.5 STD)
A618-50
(50 ksi)
T8 60.00-40.00 None Flat Bar A36
(36 ksi)
Pipe Pipe 2.875'' x 0.203''
(2.5 STD)
A618-50
(50 ksi)
T9 40.00-20.00 None Flat Bar A36
(36 ksi)
Pipe Pipe 2.875'' x 0.203''
(2.5 STD)
A618-50
(50 ksi)
T10 20.00-0.00 None Flat Bar A36
(36 ksi)
Pipe Pipe 2.875'' x 0.203''
(2.5 STD)
A618-50
(50 ksi)
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Secondary
Horizontal Type
Secondary Horizontal
Size
Secondary
Horizontal
Grade
Inner Bracing
Type
Inner Bracing Size
Inner Bracing
Grade
T1 190.00-
180.00
Solid Round A572-50
(50 ksi)
Equal Angle L 2 x 2 x 1/8 A36
(36 ksi)
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 12
tnxTower Report - version 8.0.7.4
Tower
Elevation
ft
Secondary
Horizontal Type
Secondary Horizontal
Size
Secondary
Horizontal
Grade
Inner Bracing
Type
Inner Bracing Size
Inner Bracing
Grade
T2 180.00-
160.00
Solid Round A572-50
(50 ksi)
Equal Angle L 2 x 2 x 1/8 A36
(36 ksi)
T3 160.00-
140.00
Solid Round A572-50
(50 ksi)
Equal Angle L 2 x 2 x 1/8 A36
(36 ksi)
T4 140.00-
120.00
Solid Round A572-50
(50 ksi)
Equal Angle L 2 x 2 x 1/8 A36
(36 ksi)
T5 120.00-
100.00
Solid Round A572-50
(50 ksi)
Equal Angle L 2 x 2 x 1/8 A36
(36 ksi)
T6 100.00-
80.00
Solid Round A572-50
(50 ksi)
Equal Angle L 2.5 x 2.5 x 3/16 A36
(36 ksi)
T7 80.00-60.00 Solid Round A572-50
(50 ksi)
Equal Angle L 3 x 3 x 3/16 A572-50
(50 ksi)
T8 60.00-40.00 Solid Round A572-50
(50 ksi)
Equal Angle L 3.5 x 3.5 x 1/4 A572-50
(50 ksi)
T9 40.00-20.00 Solid Round A572-50
(50 ksi)
Equal Angle L 3.5 x 3.5 x 1/4 A572-50
(50 ksi)
T10 20.00-0.00 Solid Round A572-50
(50 ksi)
Pipe Pipe 2.375'' x 0.154'' (2
STD)
A618-50
(50 ksi)
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Redundant
Bracing
Grade
Redundant
Type
Redundant
Size
K Factor
T10 20.00-
0.00
A53-B-35
(35 ksi)
Horizontal (1)
Diagonal (1)
Hip (1)
Hip Diagonal
(1)
Pipe
Pipe
Pipe
Pipe
Pipe 1.9'' x 0.145'' (1.5
STD)
Pipe 2.375'' x 0.154'' (2
STD)
Pipe 1.9'' x 0.145'' (1.5
STD)
Pipe 2.875'' x 0.203'' (2.5
STD)
1
1
1
1
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Gusset
Area
(per face)
ft2
Gusset
Thickness
in
Gusset Grade Adjust. Factor
Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle
Stitch Bolt
Spacing
Diagonals
in
Double Angle
Stitch Bolt
Spacing
Horizontals
in
Double Angle
Stitch Bolt
Spacing
Redundants
in
T1 190.00-
180.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T2 180.00-
160.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T3 160.00-
140.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T4 140.00-
120.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T5 120.00-
100.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T6 100.00-
80.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T7 80.00-
60.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T8 60.00-
40.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T9 40.00-
20.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
T10 20.00-
0.00
0.00 0.3750 A36
(36 ksi)
1.03 1 1.1 0.0000 0.0000 36.0000
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 13
tnxTower Report - version 8.0.7.4
Tower Section Geometry (cont’d)
K Factors1
Tower
Elevation
ft
Calc
K
Single
Angles
Calc
K
Solid
Rounds
Legs X
Brace
Diags
X
Y
K
Brace
Diags
X
Y
Single
Diags
X
Y
Girts
X
Y
Horiz.
X
Y
Sec.
Horiz.
X
Y
Inner
Brace
X
Y
T1 190.00-
180.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T2 180.00-
160.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T3 160.00-
140.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T4 140.00-
120.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T5 120.00-
100.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T6 100.00-
80.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T7 80.00-
60.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T8 60.00-
40.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T9 40.00-
20.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T10 20.00-
0.00
Yes No 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
1Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the out-of-
plane direction applied to the overall length.
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Net Width
Deduct
in
U
Net
Width
Deduct
in
U
Net Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
T1 190.00-
180.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T2 180.00-
160.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T3 160.00-
140.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T4 140.00-
120.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T5 120.00-
100.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T6 100.00-
80.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T7 80.00-
60.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T8 60.00-
40.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T9 40.00-
20.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T10 20.00-
0.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 14
tnxTower Report - version 8.0.7.4
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Leg
Connection
Type
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short
Horizontal
Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No.
T1 190.00-
180.00
Flange 0.8750
A325N
4 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T2 180.00-
160.00
Flange 0.8750
A325N
4 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T3 160.00-
140.00
Flange 1.0000
A325N
4 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T4 140.00-
120.00
Flange 1.0000
A325N
6 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T5 120.00-
100.00
Flange 1.0000
A325N
6 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T6 100.00-
80.00
Flange 1.0000
A325N
6 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T7 80.00-
60.00
Flange 1.0000
A325N
8 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T8 60.00-
40.00
Flange 1.0000
A325N
8 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T9 40.00-
20.00
Flange 1.0000
A325N
8 0.6250
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.6250
A325N
2 0.6250
A325N
0
T10 20.00-
0.00
Flange 1.0000
A354-BC
0 0.7500
A325N
3 0.0000
A325N
0 0.0000
A325N
0 0.6250
A325N
0 0.7500
A325N
2 0.6250
A325N
0
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Face
Offset
in
Lateral
Offset
(Frac FW)
# #
Per
Row
Clear
Spacin
g
in
Width or
Diameter
in
Perimete
r
in
Weight
plf
** Face A **
LDF7-50A(1-
5/8'')
A No No Ar (CaAa) 131.00 -
0.00
0.0000 0.38 13 7 0.5200
0.5000
1.9800 0.82
1.5'' flat
Cable Ladder
Rail
A No No Af (CaAa) 131.00 -
0.00
0.0000 0.4 2 2 24.000
0
1.5000
1.5000 1.80
** Face B **
HJ7-50A(1-
5/8'')
B No No Ar (CaAa) 187.00 -
0.00
-
2.0000
0.4 11 11 0.5200
0.5000
1.9800 1.04
HJ7-50A(1-
5/8'')
C No No Ar (CaAa) 187.00 -
0.00
-
2.0000
-0.4 1 1 0.5200
0.5000
1.9800 1.04
ATCB-
B01(5/16)
B No No Ar (CaAa) 187.00 -
0.00
-
2.0000
0.4 3 3 2.1900
0.5000
0.3150 0.07
WR-
VG86ST-
BRD( 3/4)
B No No Ar (CaAa) 187.00 -
0.00
-
2.0000
0.4 5 5 0.7740 0.7740 0.59
WR-
VG86ST-
BRD( 3/4)
C No No Ar (CaAa) 187.00 -
0.00
-
2.0000
-0.4 1 1 0.7740 0.7740 0.59
LDF2-50
(3/8'' foam)
B No No Ar (CaAa) 187.00 -
0.00
-
2.0000
0.4 2 2 0.4400 0.4400 0.08
LDF2-50
(3/8'' foam)
C No No Ar (CaAa) 187.00 -
0.00
-
2.0000
-0.4 1 1 0.4400 0.4400 0.08
1.5'' flat
Cable Ladder
Rail
B No No Af (CaAa) 187.00 -
0.00
-
2.0000
0.4 2 2 32.000
0
1.5000
1.5000 1.80
***
***
** Face C **
LDF4-
50A(1/2'')
C No No Ar (CaAa) 178.00 -
0.00
-
2.0000
-0.47 3 2 0.5200
0.5000
0.6300 0.15
2-1/4''
(Nominal)
C No No Ar (CaAa) 178.00 -
0.00
-
2.0000
-0.48 3 3 2.5000 2.5000 0.72
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 15
tnxTower Report - version 8.0.7.4
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Face
Offset
in
Lateral
Offset
(Frac FW)
# #
Per
Row
Clear
Spacin
g
in
Width or
Diameter
in
Perimete
r
in
Weight
plf
Conduit
TSZ 999
067/XXXM-
8AWG(1-
3/16)
C No No Ar (CaAa) 178.00 -
0.00
-
2.0000
-0.45 3 3 1.1900 1.1900 1.07
FIBER ONLY
CABLE
48(7/8)
C No No Ar (CaAa) 178.00 -
0.00
-
2.0000
-0.45 1 1 0.8670 0.8670 0.25
1.5'' flat
Cable Ladder
Rail
C No No Af (CaAa) 178.00 -
0.00
-
2.0000
-0.45 2 2 24.000
0
1.5000
1.5000 1.80
Safety Line
3/8
C No No Ar (CaAa) 190.00 -
0.00
0.0000 -0.5 1 1 0.3750 0.3750 0.22
3/4'' lighting
conduit (1/2''
EMT)
C No No Ar (CaAa) 190.00 -
0.00
0.0000 -0.5 1 1 0.7060 0.7060 0.30
Feed Line/Linear Appurtenances - Entered As Area
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Total
Number
CAAA
ft2/ft
Weight
plf
***
***
Feed Line/Linear Appurtenances Section Areas
Tower
Sectio
n
Tower
Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
T1 190.00-180.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
22.733
3.317
0.000
0.000
0.000
0.00
0.13
0.02
T2 180.00-160.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
64.950
42.439
0.000
0.000
0.000
0.00
0.37
0.22
T3 160.00-140.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
64.950
46.204
0.000
0.000
0.000
0.00
0.37
0.24
T4 140.00-120.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
33.814
64.950
46.204
0.000
0.000
0.000
0.16
0.37
0.24
T5 120.00-100.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
61.480
64.950
46.204
0.000
0.000
0.000
0.29
0.37
0.24
T6 100.00-80.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
61.480
64.950
46.204
0.000
0.000
0.000
0.29
0.37
0.24
T7 80.00-60.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
61.480
64.950
46.204
0.000
0.000
0.000
0.29
0.37
0.24
T8 60.00-40.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
61.480
64.950
46.204
0.000
0.000
0.000
0.29
0.37
0.24
T9 40.00-20.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
61.480
64.950
46.204
0.000
0.000
0.000
0.29
0.37
0.24
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 16
tnxTower Report - version 8.0.7.4
Tower
Sectio
n
Tower
Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
T10 20.00-0.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
61.480
64.950
46.204
0.000
0.000
0.000
0.29
0.37
0.24
Feed Line Center of Pressure
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
T1 190.00-180.00 15.0519 10.0704 15.0519 10.0704
T2 180.00-160.00 24.3594 13.4233 24.1444 13.3138
T3 160.00-140.00 26.7514 14.5583 25.9076 14.1273
T4 140.00-120.00 26.6173 5.4180 25.1775 5.1516
T5 120.00-100.00 28.1979 -1.3397 26.0070 -1.2470
T6 100.00-80.00 31.3167 -1.4888 28.8491 -1.3836
T7 80.00-60.00 34.5265 -1.6429 31.9488 -1.5325
T8 60.00-40.00 36.2311 -1.7324 33.1073 -1.5967
T9 40.00-20.00 39.3057 -1.8799 35.9318 -1.7329
T10 20.00-0.00 44.6432 -2.1250 40.4899 -1.9452
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment
Elev.
Ka
No Ice
Ka
Ice
T1 8 HJ7-50A(1-5/8") 180.00 -
187.00
0.6000 0.6000
T1 9 HJ7-50A(1-5/8") 180.00 -
187.00
0.6000 0.6000
T1 10 ATCB-B01(5/16) 180.00 -
187.00
0.6000 0.6000
T1 11 WR-VG86ST-BRD( 3/4) 180.00 -
187.00
0.6000 0.6000
T1 12 WR-VG86ST-BRD( 3/4) 180.00 -
187.00
0.6000 0.6000
T1 13 LDF2-50 (3/8" foam) 180.00 -
187.00
0.6000 0.6000
T1 14 LDF2-50 (3/8" foam) 180.00 -
187.00
0.6000 0.6000
T1 15 1.5" flat Cable Ladder Rail 180.00 -
187.00
0.6000 0.6000
T1 24 Safety Line 3/8 180.00 -
190.00
0.6000 0.6000
T1 25 3/4" lighting conduit (1/2"
EMT)
180.00 -
190.00
0.6000 0.6000
T2 8 HJ7-50A(1-5/8") 160.00 -
180.00
0.6000 0.6000
T2 9 HJ7-50A(1-5/8") 160.00 -
180.00
0.6000 0.6000
T2 10 ATCB-B01(5/16) 160.00 -
180.00
0.6000 0.6000
T2 11 WR-VG86ST-BRD( 3/4) 160.00 -
180.00
0.6000 0.6000
T2 12 WR-VG86ST-BRD( 3/4) 160.00 -
180.00
0.6000 0.6000
T2 13 LDF2-50 (3/8" foam) 160.00 -
180.00
0.6000 0.6000
T2 14 LDF2-50 (3/8" foam) 160.00 -
180.00
0.6000 0.6000
T2 15 1.5" flat Cable Ladder Rail 160.00 -
180.00
0.6000 0.6000
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 17
tnxTower Report - version 8.0.7.4
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment
Elev.
Ka
No Ice
Ka
Ice
T2 19 LDF4-50A(1/2") 160.00 -
178.00
0.6000 0.6000
T2 20 2-1/4" (Nominal) Conduit 160.00 -
178.00
0.6000 0.6000
T2 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
160.00 -
178.00
0.0000 0.0000
T2 22 FIBER ONLY CABLE
48(7/8)
160.00 -
178.00
0.0000 0.0000
T2 23 1.5" flat Cable Ladder Rail 160.00 -
178.00
0.6000 0.6000
T2 24 Safety Line 3/8 160.00 -
180.00
0.6000 0.6000
T2 25 3/4" lighting conduit (1/2"
EMT)
160.00 -
180.00
0.6000 0.6000
T3 8 HJ7-50A(1-5/8") 140.00 -
160.00
0.6000 0.6000
T3 9 HJ7-50A(1-5/8") 140.00 -
160.00
0.6000 0.6000
T3 10 ATCB-B01(5/16) 140.00 -
160.00
0.6000 0.6000
T3 11 WR-VG86ST-BRD( 3/4) 140.00 -
160.00
0.6000 0.6000
T3 12 WR-VG86ST-BRD( 3/4) 140.00 -
160.00
0.6000 0.6000
T3 13 LDF2-50 (3/8" foam) 140.00 -
160.00
0.6000 0.6000
T3 14 LDF2-50 (3/8" foam) 140.00 -
160.00
0.6000 0.6000
T3 15 1.5" flat Cable Ladder Rail 140.00 -
160.00
0.6000 0.6000
T3 19 LDF4-50A(1/2") 140.00 -
160.00
0.6000 0.6000
T3 20 2-1/4" (Nominal) Conduit 140.00 -
160.00
0.6000 0.6000
T3 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
140.00 -
160.00
0.0000 0.0000
T3 22 FIBER ONLY CABLE
48(7/8)
140.00 -
160.00
0.0000 0.0000
T3 23 1.5" flat Cable Ladder Rail 140.00 -
160.00
0.6000 0.6000
T3 24 Safety Line 3/8 140.00 -
160.00
0.6000 0.6000
T3 25 3/4" lighting conduit (1/2"
EMT)
140.00 -
160.00
0.6000 0.6000
T4 3 LDF7-50A(1-5/8") 120.00 -
131.00
0.6000 0.6000
T4 5 1.5" flat Cable Ladder Rail 120.00 -
131.00
0.6000 0.6000
T4 8 HJ7-50A(1-5/8") 120.00 -
140.00
0.6000 0.6000
T4 9 HJ7-50A(1-5/8") 120.00 -
140.00
0.6000 0.6000
T4 10 ATCB-B01(5/16) 120.00 -
140.00
0.6000 0.6000
T4 11 WR-VG86ST-BRD( 3/4) 120.00 -
140.00
0.6000 0.6000
T4 12 WR-VG86ST-BRD( 3/4) 120.00 -
140.00
0.6000 0.6000
T4 13 LDF2-50 (3/8" foam) 120.00 -
140.00
0.6000 0.6000
T4 14 LDF2-50 (3/8" foam) 120.00 -
140.00
0.6000 0.6000
T4 15 1.5" flat Cable Ladder Rail 120.00 -
140.00
0.6000 0.6000
T4 19 LDF4-50A(1/2") 120.00 -
140.00
0.6000 0.6000
T4 20 2-1/4" (Nominal) Conduit 120.00 -
140.00
0.6000 0.6000
T4 21 TSZ 999 067/XXXM-120.00 - 0.0000 0.0000
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 18
tnxTower Report - version 8.0.7.4
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment
Elev.
Ka
No Ice
Ka
Ice
8AWG(1-3/16) 140.00
T4 22 FIBER ONLY CABLE
48(7/8)
120.00 -
140.00
0.0000 0.0000
T4 23 1.5" flat Cable Ladder Rail 120.00 -
140.00
0.6000 0.6000
T4 24 Safety Line 3/8 120.00 -
140.00
0.6000 0.6000
T4 25 3/4" lighting conduit (1/2"
EMT)
120.00 -
140.00
0.6000 0.6000
T5 3 LDF7-50A(1-5/8") 100.00 -
120.00
0.6000 0.6000
T5 5 1.5" flat Cable Ladder Rail 100.00 -
120.00
0.6000 0.6000
T5 8 HJ7-50A(1-5/8") 100.00 -
120.00
0.6000 0.6000
T5 9 HJ7-50A(1-5/8") 100.00 -
120.00
0.6000 0.6000
T5 10 ATCB-B01(5/16) 100.00 -
120.00
0.6000 0.6000
T5 11 WR-VG86ST-BRD( 3/4) 100.00 -
120.00
0.6000 0.6000
T5 12 WR-VG86ST-BRD( 3/4) 100.00 -
120.00
0.6000 0.6000
T5 13 LDF2-50 (3/8" foam) 100.00 -
120.00
0.6000 0.6000
T5 14 LDF2-50 (3/8" foam) 100.00 -
120.00
0.6000 0.6000
T5 15 1.5" flat Cable Ladder Rail 100.00 -
120.00
0.6000 0.6000
T5 19 LDF4-50A(1/2") 100.00 -
120.00
0.6000 0.6000
T5 20 2-1/4" (Nominal) Conduit 100.00 -
120.00
0.6000 0.6000
T5 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
100.00 -
120.00
0.0000 0.0000
T5 22 FIBER ONLY CABLE
48(7/8)
100.00 -
120.00
0.0000 0.0000
T5 23 1.5" flat Cable Ladder Rail 100.00 -
120.00
0.6000 0.6000
T5 24 Safety Line 3/8 100.00 -
120.00
0.6000 0.6000
T5 25 3/4" lighting conduit (1/2"
EMT)
100.00 -
120.00
0.6000 0.6000
T6 3 LDF7-50A(1-5/8") 80.00 -
100.00
0.6000 0.6000
T6 5 1.5" flat Cable Ladder Rail 80.00 -
100.00
0.6000 0.6000
T6 8 HJ7-50A(1-5/8") 80.00 -
100.00
0.6000 0.6000
T6 9 HJ7-50A(1-5/8") 80.00 -
100.00
0.6000 0.6000
T6 10 ATCB-B01(5/16) 80.00 -
100.00
0.6000 0.6000
T6 11 WR-VG86ST-BRD( 3/4) 80.00 -
100.00
0.6000 0.6000
T6 12 WR-VG86ST-BRD( 3/4) 80.00 -
100.00
0.6000 0.6000
T6 13 LDF2-50 (3/8" foam) 80.00 -
100.00
0.6000 0.6000
T6 14 LDF2-50 (3/8" foam) 80.00 -
100.00
0.6000 0.6000
T6 15 1.5" flat Cable Ladder Rail 80.00 -
100.00
0.6000 0.6000
T6 19 LDF4-50A(1/2") 80.00 -
100.00
0.6000 0.6000
T6 20 2-1/4" (Nominal) Conduit 80.00 -
100.00
0.6000 0.6000
T6 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
80.00 -
100.00
0.0000 0.0000
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 19
tnxTower Report - version 8.0.7.4
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment
Elev.
Ka
No Ice
Ka
Ice
T6 22 FIBER ONLY CABLE
48(7/8)
80.00 -
100.00
0.0000 0.0000
T6 23 1.5" flat Cable Ladder Rail 80.00 -
100.00
0.6000 0.6000
T6 24 Safety Line 3/8 80.00 -
100.00
0.6000 0.6000
T6 25 3/4" lighting conduit (1/2"
EMT)
80.00 -
100.00
0.6000 0.6000
T7 3 LDF7-50A(1-5/8") 60.00 -
80.00
0.6000 0.6000
T7 5 1.5" flat Cable Ladder Rail 60.00 -
80.00
0.6000 0.6000
T7 8 HJ7-50A(1-5/8") 60.00 -
80.00
0.6000 0.6000
T7 9 HJ7-50A(1-5/8") 60.00 -
80.00
0.6000 0.6000
T7 10 ATCB-B01(5/16) 60.00 -
80.00
0.6000 0.6000
T7 11 WR-VG86ST-BRD( 3/4) 60.00 -
80.00
0.6000 0.6000
T7 12 WR-VG86ST-BRD( 3/4) 60.00 -
80.00
0.6000 0.6000
T7 13 LDF2-50 (3/8" foam) 60.00 -
80.00
0.6000 0.6000
T7 14 LDF2-50 (3/8" foam) 60.00 -
80.00
0.6000 0.6000
T7 15 1.5" flat Cable Ladder Rail 60.00 -
80.00
0.6000 0.6000
T7 19 LDF4-50A(1/2") 60.00 -
80.00
0.6000 0.6000
T7 20 2-1/4" (Nominal) Conduit 60.00 -
80.00
0.6000 0.6000
T7 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
60.00 -
80.00
0.0000 0.0000
T7 22 FIBER ONLY CABLE
48(7/8)
60.00 -
80.00
0.0000 0.0000
T7 23 1.5" flat Cable Ladder Rail 60.00 -
80.00
0.6000 0.6000
T7 24 Safety Line 3/8 60.00 -
80.00
0.6000 0.6000
T7 25 3/4" lighting conduit (1/2"
EMT)
60.00 -
80.00
0.6000 0.6000
T8 3 LDF7-50A(1-5/8") 40.00 -
60.00
0.6000 0.6000
T8 5 1.5" flat Cable Ladder Rail 40.00 -
60.00
0.6000 0.6000
T8 8 HJ7-50A(1-5/8") 40.00 -
60.00
0.6000 0.6000
T8 9 HJ7-50A(1-5/8") 40.00 -
60.00
0.6000 0.6000
T8 10 ATCB-B01(5/16) 40.00 -
60.00
0.6000 0.6000
T8 11 WR-VG86ST-BRD( 3/4) 40.00 -
60.00
0.6000 0.6000
T8 12 WR-VG86ST-BRD( 3/4) 40.00 -
60.00
0.6000 0.6000
T8 13 LDF2-50 (3/8" foam) 40.00 -
60.00
0.6000 0.6000
T8 14 LDF2-50 (3/8" foam) 40.00 -
60.00
0.6000 0.6000
T8 15 1.5" flat Cable Ladder Rail 40.00 -
60.00
0.6000 0.6000
T8 19 LDF4-50A(1/2") 40.00 -
60.00
0.6000 0.6000
T8 20 2-1/4" (Nominal) Conduit 40.00 -
60.00
0.6000 0.6000
T8 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
40.00 -
60.00
0.0000 0.0000
T8 22 FIBER ONLY CABLE 40.00 - 0.0000 0.0000
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 20
tnxTower Report - version 8.0.7.4
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment
Elev.
Ka
No Ice
Ka
Ice
48(7/8) 60.00
T8 23 1.5" flat Cable Ladder Rail 40.00 -
60.00
0.6000 0.6000
T8 24 Safety Line 3/8 40.00 -
60.00
0.6000 0.6000
T8 25 3/4" lighting conduit (1/2"
EMT)
40.00 -
60.00
0.6000 0.6000
T9 3 LDF7-50A(1-5/8") 20.00 -
40.00
0.6000 0.6000
T9 5 1.5" flat Cable Ladder Rail 20.00 -
40.00
0.6000 0.6000
T9 8 HJ7-50A(1-5/8") 20.00 -
40.00
0.6000 0.6000
T9 9 HJ7-50A(1-5/8") 20.00 -
40.00
0.6000 0.6000
T9 10 ATCB-B01(5/16) 20.00 -
40.00
0.6000 0.6000
T9 11 WR-VG86ST-BRD( 3/4) 20.00 -
40.00
0.6000 0.6000
T9 12 WR-VG86ST-BRD( 3/4) 20.00 -
40.00
0.6000 0.6000
T9 13 LDF2-50 (3/8" foam) 20.00 -
40.00
0.6000 0.6000
T9 14 LDF2-50 (3/8" foam) 20.00 -
40.00
0.6000 0.6000
T9 15 1.5" flat Cable Ladder Rail 20.00 -
40.00
0.6000 0.6000
T9 19 LDF4-50A(1/2") 20.00 -
40.00
0.6000 0.6000
T9 20 2-1/4" (Nominal) Conduit 20.00 -
40.00
0.6000 0.6000
T9 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
20.00 -
40.00
0.0000 0.0000
T9 22 FIBER ONLY CABLE
48(7/8)
20.00 -
40.00
0.0000 0.0000
T9 23 1.5" flat Cable Ladder Rail 20.00 -
40.00
0.6000 0.6000
T9 24 Safety Line 3/8 20.00 -
40.00
0.6000 0.6000
T9 25 3/4" lighting conduit (1/2"
EMT)
20.00 -
40.00
0.6000 0.6000
T10 3 LDF7-50A(1-5/8") 0.00 - 20.00 0.6000 0.6000
T10 5 1.5" flat Cable Ladder Rail 0.00 - 20.00 0.6000 0.6000
T10 8 HJ7-50A(1-5/8") 0.00 - 20.00 0.6000 0.6000
T10 9 HJ7-50A(1-5/8") 0.00 - 20.00 0.6000 0.6000
T10 10 ATCB-B01(5/16) 0.00 - 20.00 0.6000 0.6000
T10 11 WR-VG86ST-BRD( 3/4) 0.00 - 20.00 0.6000 0.6000
T10 12 WR-VG86ST-BRD( 3/4) 0.00 - 20.00 0.6000 0.6000
T10 13 LDF2-50 (3/8" foam) 0.00 - 20.00 0.6000 0.6000
T10 14 LDF2-50 (3/8" foam) 0.00 - 20.00 0.6000 0.6000
T10 15 1.5" flat Cable Ladder Rail 0.00 - 20.00 0.6000 0.6000
T10 19 LDF4-50A(1/2") 0.00 - 20.00 0.6000 0.6000
T10 20 2-1/4" (Nominal) Conduit 0.00 - 20.00 0.6000 0.6000
T10 21 TSZ 999 067/XXXM-
8AWG(1-3/16)
0.00 - 20.00 0.0000 0.0000
T10 22 FIBER ONLY CABLE
48(7/8)
0.00 - 20.00 0.0000 0.0000
T10 23 1.5" flat Cable Ladder Rail 0.00 - 20.00 0.6000 0.6000
T10 24 Safety Line 3/8 0.00 - 20.00 0.6000 0.6000
T10 25 3/4" lighting conduit (1/2"
EMT)
0.00 - 20.00 0.6000 0.6000
Discrete Tower Loads
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 21
tnxTower Report - version 8.0.7.4
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
Flash Beacon Lighting B From Leg 0.00
0.00
0.00
0.0000 190.00 No Ice 2.70 2.70 0.05
***
DBXNH-6565B-R2M w/
Mount Pipe
A From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 4.09 3.30 0.07
(2) E15S09P78 A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.75 0.34 0.02
(2) SBNHH-1D65B w/
Mount Pipe
A From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 4.09 3.30 0.07
WCS-IMFQ-AMT-43 A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.55 0.39 0.02
RRUS 32 B2 A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.74 1.67 0.05
RRUS 32 A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.86 1.78 0.06
RRUS 32 B66 A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.74 1.67 0.05
(2) DC2-48-60-0-9E A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.93 0.56 0.02
DC6-48-60-18-8F A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 1.21 1.21 0.03
DBXNH-6565B-R2M w/
Mount Pipe
B From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 4.09 3.30 0.07
(2) E15S09P78 B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.75 0.34 0.02
(2) SBNHH-1D65B w/
Mount Pipe
B From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 4.09 3.30 0.07
WCS-IMFQ-AMT-43 B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.55 0.39 0.02
RRUS 32 B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.86 1.78 0.06
RRUS 32 B2 B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.74 1.67 0.05
RRUS 32 B66 B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.74 1.67 0.05
(2) DC2-48-60-0-9E B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.93 0.56 0.02
DC6-48-60-18-8C B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.74 2.74 0.03
DBXNH-6565B-R2M w/
Mount Pipe
C From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 4.09 3.30 0.07
(2) E15S09P78 C From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.75 0.34 0.02
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 22
tnxTower Report - version 8.0.7.4
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
(2) SBNHH-1D65B w/
Mount Pipe
C From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 4.09 3.30 0.07
RRUS 32 C From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.86 1.78 0.06
RRUS 32 B2 C From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.74 1.67 0.05
RRUS 32 B66 C From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 2.74 1.67 0.05
(2) DC2-48-60-0-9E C From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 0.93 0.56 0.02
DC6-48-60-18-8F C From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 1.21 1.21 0.03
Sector Mount [SM 504-3] C None 0.0000 187.00 No Ice 31.05 31.05 1.71
(2) 1.9'' OD sched. 40
Pipe
A From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 1.71 1.71 0.03
(2) 1.9'' OD sched. 40
Pipe
B From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 1.71 1.71 0.03
(2) 1.9'' OD sched. 40
Pipe
C From Leg 4.00
0.00
0.00
0.0000 187.00 No Ice 1.71 1.71 0.03
NNHH-65B-R4 w/ Mount
Pipe
A From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 7.55 4.23 0.11
RRUS 4449 B5/B12 A From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 1.97 1.41 0.07
(3) RRUS 4478 B14 A From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 2.02 1.25 0.06
NNHH-65B-R4 w/ Mount
Pipe
B From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 7.55 4.23 0.11
(2) RRUS 4449 B5/B12 B From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 1.97 1.41 0.07
NNHH-65B-R4 w/ Mount
Pipe
C From Leg 4.00
0.00
3.00
0.0000 187.00 No Ice 7.55 4.23 0.11
***
Horizon DUO A From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 0.47 0.29 0.01
Horizon DUO B From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 0.47 0.29 0.01
Horizon DUO C From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 0.47 0.29 0.01
RRUS 31 B25 A From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 1.62 1.28 0.06
RRUS 82 W/SOLAR
SHIELD
A From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.98 1.43 0.06
(2) RRUS-11 800MHz A From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.52 1.30 0.05
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 23
tnxTower Report - version 8.0.7.4
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
ETCR-654L12H6 w/ Mount
Pipe
A From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 10.90 4.61 0.10
RADAR FILTER A From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 1.07 0.27 0.02
RRUS 31 B25 B From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 1.62 1.28 0.06
RRUS 82 W/SOLAR
SHIELD
B From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.98 1.43 0.06
(2) RRUS-11 800MHz B From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.52 1.30 0.05
ETCR-654L12H6 w/ Mount
Pipe
B From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 10.90 4.61 0.10
RADAR FILTER B From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 1.07 0.27 0.02
RRUS 31 B25 C From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 1.62 1.28 0.06
RRUS 82 W/SOLAR
SHIELD
C From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.98 1.43 0.06
(2) RRUS-11 800MHz C From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.52 1.30 0.05
ETCR-654L12H6 w/ Mount
Pipe
C From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 10.90 4.61 0.10
RADAR FILTER C From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 1.07 0.27 0.02
Connect-it PVFM-12-3-4-
96
C None 0.0000 178.00 No Ice 33.02 33.02 1.67
(2) 7'x2 1/2'' Pipe Mount A From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.01 2.01 0.04
(2) 7'x2 1/2'' Pipe Mount B From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.01 2.01 0.04
(2) 7'x2 1/2'' Pipe Mount C From Leg 4.00
0.00
0.00
0.0000 178.00 No Ice 2.01 2.01 0.04
*******
******
*******
FFHH-65C-R3_T-MOBILE
w/ Mount Pipe
A From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 12.97 6.20 0.16
AEHC w/ Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 6.96 3.45 0.11
AHFIG A From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 3.08 1.40 0.08
AHLOA_T-MOBILE A From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 2.86 1.85 0.08
HCS 2.0 A From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 0.94 0.70 0.00
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 24
tnxTower Report - version 8.0.7.4
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
(3) RNSDC-7771-PF-48 A From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 3.18 1.20 0.02
FFHH-65C-R3_T-MOBILE
w/ Mount Pipe
B From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 12.97 6.20 0.16
AEHC w/ Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 6.96 3.45 0.11
AHFIG B From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 3.08 1.40 0.08
AHLOA_T-MOBILE B From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 2.86 1.85 0.08
FFHH-65C-R3_T-MOBILE
w/ Mount Pipe
C From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 12.97 6.20 0.16
AEHC w/ Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 6.96 3.45 0.11
AHFIG C From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 3.08 1.40 0.08
AHLOA_T-MOBILE C From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 2.86 1.85 0.08
6' x 2'' Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 1.43 1.43 0.02
6' x 2'' Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 1.43 1.43 0.02
6' x 2'' Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 131.00 No Ice 1.43 1.43 0.02
C10857001C V-Boom C None 0.0000 131.00 No Ice 29.82 29.82 1.67
Dishes
Description Face
or
Leg
Dish
Type
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
Azimuth
Adjustment
°
3 dB
Beam
Width
°
Elevation
ft
Outside
Diameter
ft
Aperture
Area
ft2
Weight
K
VHLP2-18 A Paraboloid
w/Shroud (HP)
From
Leg
4.00
1.00
5.00
-60.0000 178.00 2.17 No Ice 3.72 0.03
VHLP2-11 B Paraboloid
w/Shroud (HP)
From
Leg
4.00
1.00
6.00
-90.0000 178.00 2.17 No Ice 3.72 0.03
VHLP2-18 C Paraboloid
w/Shroud (HP)
From
Leg
4.00
1.00
5.00
-15.0000 178.00 2.17 No Ice 3.72 0.03
***
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 25
tnxTower Report - version 8.0.7.4
Load Combinations
Comb.
No.
Description
1 Dead Only
2 1.2 Dead+1.0 Wind 0 deg - No Ice
3 0.9 Dead+1.0 Wind 0 deg - No Ice
4 1.2 Dead+1.0 Wind 30 deg - No Ice
5 0.9 Dead+1.0 Wind 30 deg - No Ice
6 1.2 Dead+1.0 Wind 60 deg - No Ice
7 0.9 Dead+1.0 Wind 60 deg - No Ice
8 1.2 Dead+1.0 Wind 90 deg - No Ice
9 0.9 Dead+1.0 Wind 90 deg - No Ice
10 1.2 Dead+1.0 Wind 120 deg - No Ice
11 0.9 Dead+1.0 Wind 120 deg - No Ice
12 1.2 Dead+1.0 Wind 150 deg - No Ice
13 0.9 Dead+1.0 Wind 150 deg - No Ice
14 1.2 Dead+1.0 Wind 180 deg - No Ice
15 0.9 Dead+1.0 Wind 180 deg - No Ice
16 1.2 Dead+1.0 Wind 210 deg - No Ice
17 0.9 Dead+1.0 Wind 210 deg - No Ice
18 1.2 Dead+1.0 Wind 240 deg - No Ice
19 0.9 Dead+1.0 Wind 240 deg - No Ice
20 1.2 Dead+1.0 Wind 270 deg - No Ice
21 0.9 Dead+1.0 Wind 270 deg - No Ice
22 1.2 Dead+1.0 Wind 300 deg - No Ice
23 0.9 Dead+1.0 Wind 300 deg - No Ice
24 1.2 Dead+1.0 Wind 330 deg - No Ice
25 0.9 Dead+1.0 Wind 330 deg - No Ice
26 Dead+Wind 0 deg - Service
27 Dead+Wind 30 deg - Service
28 Dead+Wind 60 deg - Service
29 Dead+Wind 90 deg - Service
30 Dead+Wind 120 deg - Service
31 Dead+Wind 150 deg - Service
32 Dead+Wind 180 deg - Service
33 Dead+Wind 210 deg - Service
34 Dead+Wind 240 deg - Service
35 Dead+Wind 270 deg - Service
36 Dead+Wind 300 deg - Service
37 Dead+Wind 330 deg - Service
Maximum Reactions
Location Condition Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Leg C Max. Vert 18 266.24 29.84 -14.90
Max. Hx 18 266.24 29.84 -14.90
Max. Hz 7 -233.03 -27.12 13.38
Min. Vert 7 -233.03 -27.12 13.38
Min. Hx 7 -233.03 -27.12 13.38
Min. Hz 18 266.24 29.84 -14.90
Leg B Max. Vert 10 257.91 -27.26 -17.12
Max. Hx 23 -218.28 24.46 15.47
Max. Hz 23 -218.28 24.46 15.47
Min. Vert 23 -218.28 24.46 15.47
Min. Hx 10 257.91 -27.26 -17.12
Min. Hz 10 257.91 -27.26 -17.12
Leg A Max. Vert 2 250.85 2.19 30.92
Max. Hx 22 138.76 5.54 17.02
Max. Hz 2 250.85 2.19 30.92
Min. Vert 15 -214.93 -2.15 -27.76
Min. Hx 11 -102.54 -5.48 -13.84
Min. Hz 15 -214.93 -2.15 -27.76
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 26
tnxTower Report - version 8.0.7.4
Tower Mast Reaction Summary
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
Dead Only 51.78 0.00 0.00 1.96 -40.03 0.00
1.2 Dead+1.0 Wind 0 deg -
No Ice
62.14 0.06 -50.65 -5516.17 -58.81 103.35
0.9 Dead+1.0 Wind 0 deg -
No Ice
46.61 0.06 -50.65 -5516.76 -46.80 103.35
1.2 Dead+1.0 Wind 30 deg -
No Ice
62.14 26.76 -46.59 -5090.55 -2967.45 146.31
0.9 Dead+1.0 Wind 30 deg -
No Ice
46.61 26.76 -46.59 -5091.13 -2955.44 146.31
1.2 Dead+1.0 Wind 60 deg -
No Ice
62.14 47.54 -27.55 -2972.91 -5174.77 95.29
0.9 Dead+1.0 Wind 60 deg -
No Ice
46.61 47.54 -27.55 -2973.50 -5162.76 95.29
1.2 Dead+1.0 Wind 90 deg -
No Ice
62.14 54.58 -0.07 -10.30 -5885.87 5.07
0.9 Dead+1.0 Wind 90 deg -
No Ice
46.61 54.58 -0.07 -10.88 -5873.86 5.07
1.2 Dead+1.0 Wind 120 deg
- No Ice
62.14 45.87 26.56 2830.83 -4930.56 -56.30
0.9 Dead+1.0 Wind 120 deg
- No Ice
46.61 45.87 26.56 2830.24 -4918.55 -56.30
1.2 Dead+1.0 Wind 150 deg
- No Ice
62.14 23.43 40.97 4451.46 -2580.57 -64.05
0.9 Dead+1.0 Wind 150 deg
- No Ice
46.61 23.43 40.97 4450.87 -2568.56 -64.05
1.2 Dead+1.0 Wind 180 deg
- No Ice
62.14 -0.01 50.67 5524.69 -45.98 -104.14
0.9 Dead+1.0 Wind 180 deg
- No Ice
46.61 -0.01 50.67 5524.10 -33.97 -104.14
1.2 Dead+1.0 Wind 210 deg
- No Ice
62.14 -26.78 46.57 5092.50 2875.13 -146.51
0.9 Dead+1.0 Wind 210 deg
- No Ice
46.61 -26.78 46.57 5091.91 2887.14 -146.51
1.2 Dead+1.0 Wind 240 deg
- No Ice
62.14 -47.51 27.58 2982.99 5073.25 -96.07
0.9 Dead+1.0 Wind 240 deg
- No Ice
46.61 -47.51 27.58 2982.40 5085.26 -96.07
1.2 Dead+1.0 Wind 270 deg
- No Ice
62.14 -54.52 0.10 19.93 5779.32 -5.88
0.9 Dead+1.0 Wind 270 deg
- No Ice
46.61 -54.52 0.10 19.34 5791.33 -5.88
1.2 Dead+1.0 Wind 300 deg
- No Ice
62.14 -45.82 -26.58 -2829.43 4825.37 56.20
0.9 Dead+1.0 Wind 300 deg
- No Ice
46.61 -45.82 -26.58 -2830.02 4837.38 56.20
1.2 Dead+1.0 Wind 330 deg
- No Ice
62.14 -23.42 -40.92 -4436.72 2482.79 63.47
0.9 Dead+1.0 Wind 330 deg
- No Ice
46.61 -23.42 -40.92 -4437.30 2494.80 63.47
Dead+Wind 0 deg - Service 51.78 0.01 -11.53 -1254.71 -42.48 23.54
Dead+Wind 30 deg - Service 51.78 6.09 -10.61 -1157.79 -704.84 33.32
Dead+Wind 60 deg - Service 51.78 10.82 -6.27 -675.56 -1207.48 21.70
Dead+Wind 90 deg - Service 51.78 12.43 -0.02 -0.92 -1369.41 1.16
Dead+Wind 120 deg -
Service
51.78 10.44 6.05 646.06 -1151.87 -12.82
Dead+Wind 150 deg -
Service
51.78 5.34 9.33 1015.11 -616.73 -14.59
Dead+Wind 180 deg -
Service
51.78 -0.00 11.54 1259.50 -39.56 -23.71
Dead+Wind 210 deg -
Service
51.78 -6.10 10.61 1161.08 625.63 -33.36
Dead+Wind 240 deg -
Service
51.78 -10.82 6.28 680.71 1126.19 -21.88
Dead+Wind 270 deg -
Service
51.78 -12.41 0.02 5.97 1286.97 -1.34
Dead+Wind 300 deg - 51.78 -10.43 -6.05 -642.89 1069.74 12.80
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 27
tnxTower Report - version 8.0.7.4
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
Service
Dead+Wind 330 deg -
Service
51.78 -5.33 -9.32 -1008.90 536.29 14.45
Solution Summary
Load
Comb.
Sum of Applied Forces Sum of Reactions
% Error PX
K
PY
K
PZ
K
PX
K
PY
K
PZ
K
1 0.00 -51.78 0.00 0.00 51.78 0.00 0.000%
2 0.06 -62.14 -50.65 -0.06 62.14 50.65 0.000%
3 0.06 -46.61 -50.65 -0.06 46.61 50.65 0.000%
4 26.76 -62.14 -46.59 -26.76 62.14 46.59 0.000%
5 26.76 -46.61 -46.59 -26.76 46.61 46.59 0.000%
6 47.54 -62.14 -27.55 -47.54 62.14 27.55 0.000%
7 47.54 -46.61 -27.55 -47.54 46.61 27.55 0.000%
8 54.58 -62.14 -0.07 -54.58 62.14 0.07 0.000%
9 54.58 -46.61 -0.07 -54.58 46.61 0.07 0.000%
10 45.87 -62.14 26.56 -45.87 62.14 -26.56 0.000%
11 45.87 -46.61 26.56 -45.87 46.61 -26.56 0.000%
12 23.43 -62.14 40.97 -23.43 62.14 -40.97 0.000%
13 23.43 -46.61 40.97 -23.43 46.61 -40.97 0.000%
14 -0.01 -62.14 50.67 0.01 62.14 -50.67 0.000%
15 -0.01 -46.61 50.67 0.01 46.61 -50.67 0.000%
16 -26.78 -62.14 46.57 26.78 62.14 -46.57 0.000%
17 -26.78 -46.61 46.57 26.78 46.61 -46.57 0.000%
18 -47.51 -62.14 27.58 47.51 62.14 -27.58 0.000%
19 -47.51 -46.61 27.58 47.51 46.61 -27.58 0.000%
20 -54.52 -62.14 0.10 54.52 62.14 -0.10 0.000%
21 -54.52 -46.61 0.10 54.52 46.61 -0.10 0.000%
22 -45.82 -62.14 -26.58 45.82 62.14 26.58 0.000%
23 -45.82 -46.61 -26.58 45.82 46.61 26.58 0.000%
24 -23.42 -62.14 -40.92 23.42 62.14 40.92 0.000%
25 -23.42 -46.61 -40.92 23.42 46.61 40.92 0.000%
26 0.01 -51.78 -11.53 -0.01 51.78 11.53 0.000%
27 6.09 -51.78 -10.61 -6.09 51.78 10.61 0.000%
28 10.82 -51.78 -6.27 -10.82 51.78 6.27 0.000%
29 12.43 -51.78 -0.02 -12.43 51.78 0.02 0.000%
30 10.44 -51.78 6.05 -10.44 51.78 -6.05 0.000%
31 5.34 -51.78 9.33 -5.34 51.78 -9.33 0.000%
32 -0.00 -51.78 11.54 0.00 51.78 -11.54 0.000%
33 -6.10 -51.78 10.61 6.10 51.78 -10.61 0.000%
34 -10.82 -51.78 6.28 10.82 51.78 -6.28 0.000%
35 -12.41 -51.78 0.02 12.41 51.78 -0.02 0.000%
36 -10.43 -51.78 -6.05 10.43 51.78 6.05 0.000%
37 -5.33 -51.78 -9.32 5.33 51.78 9.32 0.000%
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
T1 190 - 180 2.812 28 0.1325 0.0940
T2 180 - 160 2.530 28 0.1316 0.0927
T3 160 - 140 1.977 28 0.1207 0.0844
T4 140 - 120 1.488 28 0.1032 0.0669
T5 120 - 100 1.065 28 0.0870 0.0506
T6 100 - 80 0.724 28 0.0695 0.0378
T7 80 - 60 0.456 28 0.0542 0.0280
T8 60 - 40 0.256 28 0.0383 0.0201
T9 40 - 20 0.112 28 0.0246 0.0126
T10 20 - 0 0.025 35 0.0107 0.0054
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 28
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
190.00 Flash Beacon Lighting 28 2.812 0.1325 0.0940 556378
187.00 DBXNH-6565B-R2M w/ Mount
Pipe
28 2.727 0.1324 0.0937 556378
184.00 VHLP2-11 28 2.643 0.1322 0.0933 465509
183.00 VHLP2-18 28 2.615 0.1321 0.0932 408589
178.00 Horizon DUO 28 2.474 0.1311 0.0923 666368
131.00 FFHH-65C-R3_T-MOBILE w/
Mount Pipe
28 1.288 0.0958 0.0591 66261
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
T1 190 - 180 12.085 6 0.5631 0.4127
T2 180 - 160 10.886 6 0.5604 0.4070
T3 160 - 140 8.521 6 0.5161 0.3704
T4 140 - 120 6.419 6 0.4420 0.2935
T5 120 - 100 4.603 6 0.3733 0.2222
T6 100 - 80 3.134 6 0.2985 0.1659
T7 80 - 60 1.977 6 0.2330 0.1229
T8 60 - 40 1.113 6 0.1648 0.0883
T9 40 - 20 0.491 6 0.1057 0.0553
T10 20 - 0 0.107 20 0.0458 0.0237
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
190.00 Flash Beacon Lighting 6 12.085 0.5631 0.4127 161688
187.00 DBXNH-6565B-R2M w/ Mount
Pipe
6 11.726 0.5631 0.4113 161688
184.00 VHLP2-11 6 11.366 0.5626 0.4098 135388
183.00 VHLP2-18 6 11.246 0.5622 0.4091 119409
178.00 Horizon DUO 6 10.645 0.5585 0.4051 309293
131.00 FFHH-65C-R3_T-MOBILE w/
Mount Pipe
6 5.563 0.4109 0.2593 15525
Bolt Design Data
Section
No.
Elevation
ft
Component
Type
Bolt
Grade
Bolt Size
in
Number
Of
Bolts
Maximum
Load
per Bolt
K
Allowable
Load
per Bolt
K
Ratio
Load
Allowable
Allowable
Ratio
Criteria
T1 190 Leg A325N 0.8750 4 0.36 41.56 0.009 1.05 Bolt Tension
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 29
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Component
Type
Bolt
Grade
Bolt Size
in
Number
Of
Bolts
Maximum
Load
per Bolt
K
Allowable
Load
per Bolt
K
Ratio
Load
Allowable
Allowable
Ratio
Criteria
Diagonal A325N 0.6250 3 1.29 13.81 0.093 1.05 Bolt Shear
Horizontal A325N 0.6250 2 1.39 13.81 0.101 1.05 Bolt Shear
T2 180 Leg A325N 0.8750 4 6.06 41.56 0.146 1.05 Bolt Tension
Diagonal A325N 0.6250 3 2.89 13.81 0.209 1.05 Bolt Shear
Horizontal A325N 0.6250 2 2.34 13.81 0.170 1.05 Bolt Shear
T3 160 Leg A325N 1.0000 4 13.62 54.52 0.250 1.05 Bolt Tension
Diagonal A325N 0.6250 3 2.57 13.81 0.186 1.05 Bolt Shear
Horizontal A325N 0.6250 2 2.45 13.81 0.177 1.05 Bolt Shear
T4 140 Leg A325N 1.0000 6 13.47 54.52 0.247 1.05 Bolt Tension
Diagonal A325N 0.6250 3 3.15 13.81 0.228 1.05 Bolt Shear
Horizontal A325N 0.6250 2 3.36 13.81 0.244 1.05 Bolt Shear
T5 120 Leg A325N 1.0000 6 17.61 54.52 0.323 1.05 Bolt Tension
Diagonal A325N 0.6250 3 3.90 13.81 0.283 1.05 Bolt Shear
Horizontal A325N 0.6250 2 3.58 13.81 0.259 1.05 Bolt Shear
T6 100 Leg A325N 1.0000 6 22.04 54.52 0.404 1.05 Bolt Tension
Diagonal A325N 0.6250 3 3.76 13.81 0.272 1.05 Bolt Shear
Horizontal A325N 0.6250 2 3.74 13.81 0.271 1.05 Bolt Shear
T7 80 Leg A325N 1.0000 8 19.49 54.52 0.358 1.05 Bolt Tension
Diagonal A325N 0.6250 3 3.75 13.81 0.271 1.05 Bolt Shear
Horizontal A325N 0.6250 2 3.99 13.81 0.289 1.05 Bolt Shear
T8 60 Leg A325N 1.0000 8 22.33 54.52 0.410 1.05 Bolt Tension
Diagonal A325N 0.6250 3 4.05 13.81 0.293 1.05 Bolt Shear
Horizontal A325N 0.6250 2 4.56 13.81 0.330 1.05 Bolt Shear
T9 40 Leg A325N 1.0000 8 25.18 54.52 0.462 1.05 Bolt Tension
Diagonal A325N 0.6250 3 4.17 13.81 0.302 1.05 Bolt Shear
Horizontal A325N 0.6250 2 4.84 13.81 0.351 1.05 Bolt Shear
T10 20 Diagonal A325N 0.7500 3 6.37 19.88 0.321 1.05 Bolt Shear
Horizontal A325N 0.7500 2 5.28 19.88 0.266 1.05 Bolt Shear
Compression Checks
Leg Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 2.875'' x 0.276'' (2.5
XS)
10.00 5.00 64.9
K=1.00
2.2535 -4.34 74.51 0.058 1
T2 180 - 160 Pipe 3.5'' x 0.300'' (3 XS) 20.00 6.67 70.4
K=1.00
3.0159 -30.61 94.46 0.324 1
T3 160 - 140 Pipe 4.5'' x 0.337'' (4 XS) 20.04 6.68 54.3
K=1.00
4.4074 -61.88 159.90 0.387 1
T4 140 - 120 Pipe 5.563'' x 0.375'' (5
XS)
20.04 6.68 43.6
K=1.00
6.1120 -92.29 239.38 0.386 1
T5 120 - 100 Pipe 6.625'' x 0.340'' (6 20.04 10.02 54.0 6.7133 -119.10 244.02 0.488 1
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 30
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
EHS) K=1.00 T6 100 - 80 Pipe 6.625'' x 0.432'' (6
XS)
20.05 10.03 54.8
K=1.00
8.4049 -148.45 303.62 0.489 1
T7 80 - 60 Pipe 6.625'' x 0.432'' (6
XS)
20.06 10.03 54.8
K=1.00
8.4049 -175.36 303.58 0.578 1
T8 60 - 40 Pipe 8.625'' x 0.375'' (8
EHS)
20.05 10.03 41.2
K=1.00
9.7193 -201.68 386.31 0.522 1
T9 40 - 20 Pipe 8.625'' x 0.375'' (8
EHS)
20.05 10.03 41.2
K=1.00
9.7193 -228.38 386.31 0.591 1
T10 20 - 0 Pipe 8.625'' x 0.500'' (8
XS)
20.05 10.03 41.8
K=1.00
12.762
7
-241.00 505.43 0.477 1
1 P u / fPn controls
Diagonal Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 2.375'' x 0.154'' (2
STD)
6.58 6.39 97.4
K=1.00
1.0745 -3.87 24.15 0.160 1
T2 180 - 160 Pipe 2.375'' x 0.218'' (2
XS)
7.94 7.67 120.1
K=1.00
1.4773 -8.66 23.14 0.374 1
T3 160 - 140 Pipe 2.375'' x 0.154'' (2
STD)
8.55 8.25 125.8
K=1.00
1.0745 -7.70 15.33 0.502 1
T4 140 - 120 Pipe 2.375'' x 0.154'' (2
STD)
9.24 8.91 135.8
K=1.00
1.0745 -9.44 13.17 0.717 1
T5 120 - 100 Pipe 2.875'' x 0.203'' (2.5
STD)
12.52 12.06 152.7
K=1.00
1.7040 -11.70 16.50 0.709 1
T6 100 - 80 Pipe 3.5'' x 0.216'' (3
STD)
13.31 12.89 132.9
K=1.00
2.2285 -11.27 28.50 0.395 1
T7 80 - 60 Pipe 3.5'' x 0.216'' (3
STD)
14.21 13.82 142.5
K=1.00
2.2285 -11.24 24.78 0.454 1
T8 60 - 40 Pipe 3.5'' x 0.216'' (3
STD)
15.12 14.64 151.0
K=1.00
2.2285 -12.15 22.07 0.550 1
T9 40 - 20 Pipe 3.5'' x 0.216'' (3
STD)
16.08 15.62 161.1
K=1.00
2.2285 -12.51 19.40 0.645 1
T10 20 - 0 (37515-2715) 2.875'' x
.276'' Pipe w/ 3.5'' x .300''
Half Sleeve
24.33 12.17 158.8
K=1.00
3.7615 -19.12 31.19 0.616 1
1 P u / fPn controls
Horizontal Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 1.9'' x 0.145'' (1.5
STD)
8.52 4.14 79.8
K=1.00
0.7995 -2.69 22.58 0.119 1
T2 180 - 160 Pipe 1.9'' x 0.145'' (1.5
STD)
8.60 4.15 80.0
K=1.00
0.7995 -4.64 22.52 0.206 1
T3 160 - 140 Pipe 1.9'' x 0.145'' (1.5
STD)
10.01 4.82 92.9
K=1.00
0.7995 -4.89 19.14 0.256 1
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 31
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T4 140 - 120 Pipe 2.375'' x 0.154'' (2
STD)
12.10 5.82 88.7
K=1.00
1.0745 -6.72 27.21 0.247 1
T5 120 - 100 Pipe 2.375'' x 0.154'' (2
STD)
13.92 6.68 101.9
K=1.00
1.0745 -7.16 22.64 0.316 1
T6 100 - 80 Pipe 2.375'' x 0.154'' (2
STD)
16.29 7.87 120.0
K=1.00
1.0745 -7.48 16.86 0.444 1
T7 80 - 60 Pipe 2.875'' x 0.203'' (2.5
STD)
18.86 9.15 115.9
K=1.00
1.7040 -7.95 28.64 0.278 1
T8 60 - 40 Pipe 2.875'' x 0.203'' (2.5
STD)
21.43 10.35 131.1
K=1.00
1.7040 -9.01 22.38 0.402 1
T9 40 - 20 Pipe 2.875'' x 0.203'' (2.5
STD)
23.93 11.60 147.0
K=1.00
1.7040 -9.39 17.82 0.527 1
T10 20 - 0 Pipe 2.875'' x 0.203'' (2.5
STD)
25.18 12.23 154.9
K=1.00
1.7040 -10.56 16.05 0.658 1
1 P u / fPn controls
Top Girt Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 1.9'' x 0.145'' (1.5
STD)
8.50 4.13 79.6
K=1.00
0.7995 -0.78 22.63 0.035 1
1 P u / fPn controls
Redundant Horizontal (1) Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 1.9'' x 0.145'' (1.5
STD)
6.29 5.93 114.4
K=1.00
0.7995 -4.18 12.89 0.325 1
1 P u / fPn controls
Redundant Diagonal (1) Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 2.375'' x 0.154'' (2
STD)
11.50 10.77 164.2
K=1.00
1.0745 -3.82 9.00 0.425 1
1 P u / fPn controls
Redundant Hip (1) Design Data (Compression)
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 32
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 1.9'' x 0.145'' (1.5
STD)
6.29 6.29 121.3
K=1.00
0.7995 -0.03 11.86 0.002 1
1 P u / fPn controls
Redundant Hip Diagonal (1) Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 2.875'' x 0.203'' (2.5
STD)
15.07 15.07 190.9
K=1.00
1.7040 -0.06 10.56 0.006 1
1 P u / fPn controls
Inner Bracing Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 L 2 x 2 x 1/8 4.25 4.25 128.3
K=1.00
0.4844 -0.01 8.42 0.002 1
T2 180 - 160 L 2 x 2 x 1/8 4.28 4.28 129.3
K=1.00
0.4844 -0.00 8.29 0.001 1
T3 160 - 140 L 2 x 2 x 1/8 5.01 5.01 151.1
K=1.00
0.4844 -0.00 6.07 0.001 1
T4 140 - 120 L 2 x 2 x 1/8 6.05 6.05 182.6
K=1.00
0.4844 -0.01 4.16 0.002 1
T5 120 - 100 L 2 x 2 x 1/8 6.96 6.96 210.0
K=1.00
0.4844 -0.01 3.14 0.002 1
T6 100 - 80 L 2.5 x 2.5 x 3/16 8.15 8.15 197.5
K=1.00
0.9020 -0.01 6.62 0.001 1
T7 80 - 60 L 3 x 3 x 3/16 9.43 9.43 189.9
K=1.00
1.0900 -0.01 8.65 0.001 1
T8 60 - 40 L 3.5 x 3.5 x 1/4 10.71 10.71 185.2
K=1.00
1.6900 -0.01 14.10 0.001 1
T9 40 - 20 L 3.5 x 3.5 x 1/4 11.96 11.96 206.9
K=1.00
1.6900 -0.01 11.30 0.001 1
T10 20 - 0 Pipe 2.375'' x 0.154'' (2
STD)
12.59 12.59 191.9
K=1.00
1.0745 -0.01 6.59 0.002 1
1 P u / fPn controls
Tension Checks
Leg Design Data (Tension)
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 33
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 2.875'' x 0.276'' (2.5
XS)
10.00 5.00 64.9 2.2535 1.03 101.41 0.010 1
T2 180 - 160 Pipe 3.5'' x 0.300'' (3 XS) 20.00 6.67 70.4 3.0159 24.25 135.72 0.179 1
T3 160 - 140 Pipe 4.5'' x 0.337'' (4 XS) 20.04 6.68 54.3 4.4074 54.47 198.34 0.275 1
T4 140 - 120 Pipe 5.563'' x 0.375'' (5
XS)
20.04 6.68 43.6 6.1120 80.81 275.04 0.294 1
T5 120 - 100 Pipe 6.625'' x 0.340'' (6
EHS)
20.04 10.02 54.0 6.7133 105.67 302.10 0.350 1
T6 100 - 80 Pipe 6.625'' x 0.432'' (6
XS)
20.05 10.03 54.8 8.4049 132.26 378.22 0.350 1
T7 80 - 60 Pipe 6.625'' x 0.432'' (6
XS)
20.06 10.03 54.8 8.4049 155.94 378.22 0.412 1
T8 60 - 40 Pipe 8.625'' x 0.375'' (8
EHS)
20.05 10.03 41.2 9.7193 178.63 437.37 0.408 1
T9 40 - 20 Pipe 8.625'' x 0.375'' (8
EHS)
20.05 10.03 41.2 9.7193 201.44 437.37 0.461 1
T10 20 - 0 Pipe 8.625'' x 0.500'' (8
XS)
20.05 10.03 41.8 12.762
7
211.02 574.32 0.367 1
1 P u / fPn controls
Diagonal Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 2.375'' x 0.154'' (2
STD)
6.58 6.39 97.4 1.0745 3.79 48.35 0.078 1
T2 180 - 160 Pipe 2.375'' x 0.218'' (2
XS)
7.94 7.67 120.1 1.4773 8.57 66.48 0.129 1
T3 160 - 140 Pipe 2.375'' x 0.154'' (2
STD)
8.55 8.25 125.8 1.0745 7.60 48.35 0.157 1
T4 140 - 120 Pipe 2.375'' x 0.154'' (2
STD)
9.24 8.91 135.8 1.0745 9.30 48.35 0.192 1
T5 120 - 100 Pipe 2.875'' x 0.203'' (2.5
STD)
12.19 11.73 148.5 1.7040 11.53 76.68 0.150 1
T6 100 - 80 Pipe 3.5'' x 0.216'' (3
STD)
13.31 12.89 132.9 2.2285 10.98 100.28 0.109 1
T7 80 - 60 Pipe 3.5'' x 0.216'' (3
STD)
14.21 13.82 142.5 2.2285 10.86 100.28 0.108 1
T8 60 - 40 Pipe 3.5'' x 0.216'' (3
STD)
15.12 14.64 151.0 2.2285 11.67 100.28 0.116 1
T9 40 - 20 Pipe 3.5'' x 0.216'' (3
STD)
16.08 15.62 161.1 2.2285 11.96 100.28 0.119 1
T10 20 - 0 (37515-2715) 2.875'' x
.276'' Pipe w/ 3.5'' x .300''
Half Sleeve
24.33 12.17 158.8 3.7615 18.03 118.49 0.152 1
1 P u / fPn controls
Horizontal Design Data (Tension)
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 34
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 1.9'' x 0.145'' (1.5
STD)
8.52 4.14 79.8 0.7995 2.78 35.98 0.077 1
T2 180 - 160 Pipe 1.9'' x 0.145'' (1.5
STD)
8.60 4.15 80.0 0.7995 4.69 35.98 0.130 1
T3 160 - 140 Pipe 1.9'' x 0.145'' (1.5
STD)
10.01 4.82 92.9 0.7995 4.83 35.98 0.134 1
T4 140 - 120 Pipe 2.375'' x 0.154'' (2
STD)
12.10 5.82 88.7 1.0745 6.65 48.35 0.138 1
T5 120 - 100 Pipe 2.375'' x 0.154'' (2
STD)
13.92 6.68 101.9 1.0745 7.10 48.35 0.147 1
T6 100 - 80 Pipe 2.375'' x 0.154'' (2
STD)
16.29 7.87 120.0 1.0745 7.45 48.35 0.154 1
T7 80 - 60 Pipe 2.875'' x 0.203'' (2.5
STD)
18.86 9.15 115.9 1.7040 7.97 76.68 0.104 1
T8 60 - 40 Pipe 2.875'' x 0.203'' (2.5
STD)
21.43 10.35 131.1 1.7040 9.11 76.68 0.119 1
T9 40 - 20 Pipe 2.875'' x 0.203'' (2.5
STD)
23.93 11.60 147.0 1.7040 9.69 76.68 0.126 1
T10 20 - 0 Pipe 2.875'' x 0.203'' (2.5
STD)
25.18 12.23 154.9 1.7040 10.41 76.68 0.136 1
1 P u / fPn controls
Top Girt Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 Pipe 1.9'' x 0.145'' (1.5
STD)
8.50 4.13 79.6 0.7995 0.78 35.98 0.022 1
1 P u / fPn controls
Redundant Horizontal (1) Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 1.9'' x 0.145'' (1.5
STD)
6.29 5.93 114.4 0.7995 4.18 25.18 0.166 1
1 P u / fPn controls
Redundant Diagonal (1) Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 2.375'' x 0.154'' (2
STD)
11.50 10.77 164.2 1.0745 3.82 33.85 0.113 1
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 35
tnxTower Report - version 8.0.7.4
1 P u / fPn controls
Redundant Hip (1) Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 1.9'' x 0.145'' (1.5
STD)
6.29 6.29 121.3 0.7995 0.01 25.18 0.000 1
1 P u / fPn controls
Redundant Hip Diagonal (1) Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T10 20 - 0 Pipe 2.875'' x 0.203'' (2.5
STD)
15.07 15.07 190.9 1.7040 0.06 53.68 0.001 1
1 P u / fPn controls
Inner Bracing Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
fPn
K
Ratio
Pu
fPn
T1 190 - 180 L 2 x 2 x 1/8 4.25 4.25 81.4 0.4844 0.01 15.69 0.001 1
T2 180 - 160 L 2 x 2 x 1/8 4.28 4.28 82.1 0.4844 0.00 15.69 0.000 1
T3 160 - 140 L 2 x 2 x 1/8 4.31 4.31 82.6 0.4844 0.00 15.69 0.000 1
T4 140 - 120 L 2 x 2 x 1/8 5.70 5.70 109.3 0.4844 0.00 15.69 0.000 1
T5 120 - 100 L 2 x 2 x 1/8 6.40 6.40 122.6 0.4844 0.00 15.69 0.000 1
T6 100 - 80 L 2.5 x 2.5 x 3/16 7.52 7.52 116.0 0.9020 0.00 29.22 0.000 1
1 P u / fPn controls
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
T1 190 - 180 Leg Pipe 2.875'' x 0.276'' (2.5 XS) 3 -4.34 78.23 5.5 Pass
T2 180 - 160 Leg Pipe 3.5'' x 0.300'' (3 XS) 29 -30.61 99.18 30.9 Pass
T3 160 - 140 Leg Pipe 4.5'' x 0.337'' (4 XS) 67 -61.88 167.90 36.9 Pass
T4 140 - 120 Leg Pipe 5.563'' x 0.375'' (5 XS) 106 -92.29 251.35 36.7 Pass
T5 120 - 100 Leg Pipe 6.625'' x 0.340'' (6 EHS) 145 -119.10 256.22 46.5 Pass
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 36
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
T6 100 - 80 Leg Pipe 6.625'' x 0.432'' (6 XS) 172 -148.45 318.80 46.6 Pass
T7 80 - 60 Leg Pipe 6.625'' x 0.432'' (6 XS) 199 -175.36 318.76 55.0 Pass
T8 60 - 40 Leg Pipe 8.625'' x 0.375'' (8 EHS) 226 -201.68 405.62 49.7 Pass
T9 40 - 20 Leg Pipe 8.625'' x 0.375'' (8 EHS) 253 -228.38 405.62 56.3 Pass
T10 20 - 0 Leg Pipe 8.625'' x 0.500'' (8 XS) 280 -241.00 530.71 45.4 Pass
T1 190 - 180 Diagonal Pipe 2.375'' x 0.154'' (2 STD) 11 -3.87 25.36 15.2 Pass
T2 180 - 160 Diagonal Pipe 2.375'' x 0.218'' (2 XS) 32 -8.66 24.29 35.6 Pass
T3 160 - 140 Diagonal Pipe 2.375'' x 0.154'' (2 STD) 71 -7.70 16.10 47.8 Pass
T4 140 - 120 Diagonal Pipe 2.375'' x 0.154'' (2 STD) 110 -9.44 13.83 68.3 Pass
T5 120 - 100 Diagonal Pipe 2.875'' x 0.203'' (2.5
STD)
149 -11.70 17.33 67.5 Pass
T6 100 - 80 Diagonal Pipe 3.5'' x 0.216'' (3 STD) 176 -11.27 29.92 37.6 Pass
T7 80 - 60 Diagonal Pipe 3.5'' x 0.216'' (3 STD) 203 -11.24 26.02 43.2 Pass
T8 60 - 40 Diagonal Pipe 3.5'' x 0.216'' (3 STD) 230 -12.15 23.18 52.4 Pass
T9 40 - 20 Diagonal Pipe 3.5'' x 0.216'' (3 STD) 257 -12.51 20.36 61.4 Pass
T10 20 - 0 Diagonal (37515-2715) 2.875'' x .276''
Pipe w/ 3.5'' x .300'' Half
Sleeve
284 -19.12 31.19 58.6 Pass
T1 190 - 180 Horizontal Pipe 1.9'' x 0.145'' (1.5 STD) 10 -2.69 23.71 11.4 Pass
T2 180 - 160 Horizontal Pipe 1.9'' x 0.145'' (1.5 STD) 31 -4.64 23.65 19.6 Pass
T3 160 - 140 Horizontal Pipe 1.9'' x 0.145'' (1.5 STD) 70 -4.89 20.10 24.3 Pass
T4 140 - 120 Horizontal Pipe 2.375'' x 0.154'' (2 STD) 109 -6.72 28.57 23.5 Pass
T5 120 - 100 Horizontal Pipe 2.375'' x 0.154'' (2 STD) 148 -7.16 23.77 30.1 Pass
T6 100 - 80 Horizontal Pipe 2.375'' x 0.154'' (2 STD) 175 -7.48 17.71 42.2 Pass
T7 80 - 60 Horizontal Pipe 2.875'' x 0.203'' (2.5
STD)
202 -7.95 30.07 26.4
27.5 (b)
Pass
T8 60 - 40 Horizontal Pipe 2.875'' x 0.203'' (2.5
STD)
229 -9.01 23.50 38.3 Pass
T9 40 - 20 Horizontal Pipe 2.875'' x 0.203'' (2.5
STD)
256 -9.39 18.71 50.2 Pass
T10 20 - 0 Horizontal Pipe 2.875'' x 0.203'' (2.5
STD)
283 -10.56 16.85 62.7 Pass
T1 190 - 180 Top Girt Pipe 1.9'' x 0.145'' (1.5 STD) 5 -0.78 23.77 3.3 Pass
T10 20 - 0 Redund Horz 1
Bracing
Pipe 1.9'' x 0.145'' (1.5 STD) 285 -4.18 13.53 30.9 Pass
T10 20 - 0 Redund Diag 1
Bracing
Pipe 2.375'' x 0.154'' (2 STD) 305 -3.82 9.45 40.5 Pass
T10 20 - 0 Redund Hip 1
Bracing
Pipe 1.9'' x 0.145'' (1.5 STD) 308 -0.03 12.45 0.2 Pass
T10 20 - 0 Redund Hip
Diagonal 1 Bracing
Pipe 2.875'' x 0.203'' (2.5
STD)
298 -0.06 11.09 0.6 Pass
T1 190 - 180 Inner Bracing L 2 x 2 x 1/8 25 -0.01 8.84 0.2 Pass
T2 180 - 160 Inner Bracing L 2 x 2 x 1/8 41 -0.00 8.65 0.1 Pass
T3 160 - 140 Inner Bracing L 2 x 2 x 1/8 81 -0.00 6.37 0.1 Pass
T4 140 - 120 Inner Bracing L 2 x 2 x 1/8 120 -0.01 4.37 0.2 Pass
T5 120 - 100 Inner Bracing L 2 x 2 x 1/8 159 -0.01 3.30 0.2 Pass
T6 100 - 80 Inner Bracing L 2.5 x 2.5 x 3/16 186 -0.01 6.95 0.2 Pass
T7 80 - 60 Inner Bracing L 3 x 3 x 3/16 213 -0.01 9.09 0.1 Pass
T8 60 - 40 Inner Bracing L 3.5 x 3.5 x 1/4 240 -0.01 14.80 0.2 Pass
T9 40 - 20 Inner Bracing L 3.5 x 3.5 x 1/4 267 -0.01 11.87 0.2 Pass
T10 20 - 0 Inner Bracing Pipe 2.375'' x 0.154'' (2 STD) 312 -0.01 6.92 0.3 Pass
Summary
Leg (T9) 56.3 Pass
Diagonal
(T4)
68.3 Pass
Horizontal
(T10)
62.7 Pass
Top Girt
(T1)
3.3 Pass
Redund
Horz 1
Bracing
(T10)
30.9 Pass
Redund
Diag 1
Bracing
(T10)
40.5 Pass
Redund
Hip 1
Bracing
0.2 Pass
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 37
tnxTower Report - version 8.0.7.4
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
(T10)
Redund
Hip
Diagonal 1
Bracing
(T10)
0.6 Pass
Inner
Bracing
(T10)
0.3 Pass
Bolt
Checks
44.0 Pass
RATING = 68.3 Pass
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 38
tnxTower Report - version 8.0.7.4
APPENDIX B
BASE LEVEL DRAWING
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 39
tnxTower Report - version 8.0.7.4
August 04, 2020
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37520-0618.003.8700, Order 525878, Revision 0 Page 40
tnxTower Report - version 8.0.7.4
APPENDIX C
ADDITIONAL CALCULATIONS
Jo
b
N
u
m
b
e
r
:
Si
t
e
N
u
m
b
e
r
:
Ma
x
r
a
t
i
o
:
1.
0
5
Si
t
e
N
a
m
e
:
Ra
t
i
n
g
i
n
c
l
u
d
e
s
m
a
x
r
a
t
i
o
?
Y
WO
N
o
.
:
Or
d
e
r
N
o
.
:
En
g
i
n
e
e
r
:
v1
.
6
-
E
f
f
e
c
t
i
v
e
6
/
1
8
/
2
0
D
a
t
e
:
0
8
/
0
4
/
2
0
Loads
Bo
t
t
o
m
To
p
L u
Ar
e
a
a i
Ar
e
a
a i /r
i
F'
y
F cr
Co
m
p
.
C
o
p
e
C
r
u
s
h
i
n
g
C
o
m
p
.
ft
f
t
in
in
2
in
in
2
a i /r
ib
ks
i
k
s
i
k
i
p
k
i
p
k
i
p
k
i
p
0
2
0
P
i
p
e
2
.
8
7
5
"
x
0
.
2
7
6
"
1
4
6
.
0
2
.
2
5
1
/
2
S
l
e
e
v
e
3
.
5
0
0
"
x
0
.
3
0
0
"
2
4
.
0
1
.
5
1
B
o
l
t
e
d
4
8
.
2
3
1
5
7
.
8
6
1
6
5
.
0
6
3
5
.
0
0
9
.
2
1
3
1
.
1
9
N
/
A
N
/
A
1
9
.
2
0
58.6%
P
A
S
S
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
#N
/
A
#N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#
N
/
A
#N/A
#
N
/
A
37
5
2
0
-
0
6
1
8
.
0
0
3
.
8
7
0
0
81
2
5
6
5
MA
Y
P
O
R
T
18
7
4
3
5
2
52
5
8
7
8
R
e
v
0
SF
M
Rating
Mo
d
i
f
i
e
d
M
e
m
b
e
r
C
a
l
c
u
l
a
t
i
o
n
S
u
m
m
a
r
y
-
T
I
A
-
2
2
2
-
H
Ty
p
e
Ty
p
e
Re
i
n
f
o
r
c
e
m
e
n
t
Ex
i
s
t
i
n
g
M
e
m
b
e
r
El
e
v
a
t
i
o
n
s
Bu
i
l
t
-
u
p
M
e
m
b
e
r
C
a
p
a
c
i
t
y
:
ɸ
P
n
(K
L
/
r
)
m
(K
L
/
r
)
o
Co
n
n
e
c
t
i
o
n
Ty
p
e
Self Support Anchor Rod Capacity
*TIA-222-H Section 15.5 Applied
Anchor Rod Data Anchor Rod Summary (units of kips, kip-in)
(10) 1" ø bolts (A354-BC N; Fy=109 ksi, Fu=125 ksi) Pu_t = 23.3 φPn_t = 56.81 Stress Rating
l ar (in):0 Vu = 3 φVn = 36.82 16.7%
Mu = n/a φMn = n/a Pass
Uplift
233.00
30.00
Total Eccentricity (in) 0.000
Connection Properties Analysis Results
Axial Force (kips) 0.00
Shear Force (kips) 33.00
Considered Eccentricity
Leg Mod Eccentricity (in) 0.000
*Anchor Rod Eccentricity Applied
Anchor Rod N.A Shift (in) 0.000
Comp.
Applied Loads
Grout Considered:No
Site Info
BU # 812565
Site Name MAYPORT
Order # 525878 Rev. 0
Analysis Considerations
TIA-222 Revision H
Analysis Date: 8/4/2020CCIplate - Version 3.7.1
5968 ft-kips Capacity Demand Rating* Check
62 kips 381.09 55.00 13.7% Pass
55 kips 3.75 1.54 39.1% Pass
266 kips 14103.70 6561.55 46.5% Pass
33 kips 1600.23 49.50 2.9% Pass
233 kips 1041.61 45.00 4.1% Pass
30 kips 7637.76 270.32 3.4% Pass
190 ft 17293.20 267.79 1.5% Pass
27.677083 ft 1990.28 23.34 1.1% Pass
2.5 in 0.164 0.015 8.8% Pass
in 8379.89 29.70 0.3% Pass
0.164 0.014 8.2% Pass
8379.89 27.00 0.3% Pass
Square
4.0 ft
0.50 ft Soil Rating*:46.5%
9 Structural Rating*:8.8%
16
3
4
Tie
3 in
6.00 ft
36.50 ft
5.00 ft
9
72
3 in
60 ksi
3 ksi
150 pcf
110 pcf
5.000 ksf <-- Toggle between Gross and Net
0.000 ksf
30 degrees
5
3.0 ft
No
4.5 ft
Top & Bot. Pad Rein. Different?:
Anchor Bolt Circle, BC:Flexural 2-way (Comp) (kip*ft)
Flexural 2-way (Tension) (kip*ft)
*Rating per TIA-222-H Section
15.5
Pad Flexure (kip*ft)
Pad Shear - Tension 2-way (ksi)
Lateral (Sliding) (kips)
Foundation Analysis Checks
Tower Centroid Offset?:
Pier Properties
Global Moment, M:
Leg Uplift. Shear, Vu_uplift:
BP Dist. Above Fdn, bpdist:
Block Foundation?:
Pad Shear - Comp 2-way (ksi)
Pier Compression (kip)
Pier Flexure (Comp.) (kip*ft)
Pad Shear - 1-way (kips)
Tower Height, H:
Base Face Width, BW:
Leg Uplift, Puplift:Pier Flexure (Tension) (kip*ft)
Bearing Pressure (ksf)
Overturning (kip*ft)
SST Unit Base Foundation
BU # :
Site Name:
Leg Compression, Pcomp:
TIA-222 Revision:
App. Number:
Superstructure Analysis Reactions
H
Global Axial, P:
Global Shear, V:
812565
MAYPORT
525878 Rev.0
Leg Comp. Shear, Vu_comp:
Pier Diameter, dpier:
Pier Rebar Quantity, mc:
Pier Tie/Spiral Size, St:
Pier Clear Cover, ccpier:
Neglected Depth, N:
Pier Shape:
Pier Rebar Size, Sc:
Pier Reinforcement Type:
Ext. Above Grade, E:
Pier Tie/Spiral Quantity, mt:
Pad Width, W:
Pad Thickness, T:
Pad Rebar Size (Bottom), Sp:
Foundation Bearing on Rock?
Pad Properties
Groundwater Depth, gw:
Base Friction, µ:
Cohesion, Cu:
Friction Angle, :
Total Soil Unit Weight, γ:
Ultimate Gross Bearing, Qult:
SPT Blow Count, Nblows:
Soil Properties
Depth, D:
Pad Clear Cover, ccpad:
Dry Concrete Density, δc:
Pad Rebar Quantity (Bottom), mp:
Rebar Grade, Fy:
Concrete Compressive Strength, F'c:
Material Properties
Version 3.2.1