2009 Vela Norte Cir GSRS20-0068 gas permitOWNER:ADDRESS:CITY:STATE:ZIP:
Kevin Bridger 2009 VELA NORTE CIR JACKSONVILLE FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
FLORIDA PROPANE-Griffis
Gas 461 TRESCA RD JACKSONVILLE FL 32225
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169506 1110 SELVA NORTE UNIT 01
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
2009 VELA NORTE CIR MECHANICAL RESIDENTIAL GAS GAS PIPING - 200 lb TANK
AND LINE TO GENERATOR $500.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
GAS PIPING OUTLETS 455-0000-322-1000 1 $10.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TANKS GAS OR LIQUEFIED PETROLEUM 455-0000-322-1000 200 $20.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/8/2020
PERMIT NUMBER
GSRS20-0068
ISSUED: 10/8/2020
EXPIRES: 4/6/2021
MECHANICAL RESIDENTIAL GAS
PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
TOTAL: $89.00
2 of 2Issued Date: 10/8/2020
PERMIT NUMBER
GSRS20-0068
ISSUED: 10/8/2020
EXPIRES: 4/6/2021
MECHANICAL RESIDENTIAL GAS
PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
GSRS20-0068
Revision Request/Correction to Comments ALL INFORMATION
HIGHLIGHTED IN
City of Atlantic Beach Building Department GRAY IS REQUIRED.
T. .tet_.'%I
i) 800 Seminole Rd, Atlantic Beach,6FL32233C5ZD-a4, e
Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT n:
ElRevision to Issued Permit OR n Corrections to Comments Date: 227 // 20Z-l--)
Project Address: 2-061 V¢/et Ade. e/gek
Contractor/Contact Name: 612/may/Y KA S
Contact Phone: ?29- 761/- 934 Email: j„, 1,5
Description of Proposed Revision/Corrections:
72-?. - ioO 47,#A1 7:---,14/f /M.
M 14. !'
I affirm the revision/correction to comments is inclusive of the proposed changes.
printed name)
Will proposed revision/corrections add additional square footage to original submittal?
No Q Yes(additional s.f.to be added:
ill proposed revision/corrections add additional increase in building value to original submittal?
No Q*Yes (additional increase in building value: $ Contractor must sign if increase in valuation)
01
Signature of Contractor/Agent:
Office Use Only)
Approved Denied Not Applicable to Department Permit Fee Due$
Revision/Plan Review Comments
Department Review Required:
Building
Planning&Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities
Public Safety Date
Fire Services Updated 10/17/18
MAP SHOWING BOUNDARY SURVEY OF
z LOTC55, ACCORDINGRDING TO THE PLAT OF
SEL V/A NO 1-
TEs UNIT ONE
AS RECORDED IN PLAT BOOK 39, PAGE(S) 94,94A AND 94B, OF THE CURRENT
PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.
O
4 . v
W a
C-5 • W
z VELA NORTE CIRCLEGTriQciso•R/Kf
OG
cn N 04'39'18" E N 04'16'48" E o"'/A.
R48.31 'R) 18.00' (R)
W W N 04'38.20' E 46.30' (M) N 03'32.23• E 17.76• (M)N
E, 593 ,,`tel
t 5 R R-1375.00' L-17. 76' (M)
GT4 F E- 4, ` `44, vi,
IRON PIPE 1/2
0,,•(. `.. LB
1048
CONC IRON PIPE
IRON PIPE
A E"' p`'1- -{ y PT . DRIVE LBPLC48 (
CNR)
H-H O4 O A41.'
a < 1--H ot)
P'ryy.
o
E TCOE- E- a]
Z 5
W PAD
HN GO - 10' ..IEAW1--1 0-I r--1 CONC
G CD ,-1 E- WALK EASEMENT
OCI
O O. IRON PIPE •
LOT I1'
E-
aW4
LB 1o48
55
A PC
W A BRICK
1--1 WWALLS 1 CK WALLS
TA.
O 23.0•b 15.6• I 12.6• AND COLUMNS
E 12.9'c • ND ' 12.3•16.o 'mIKo7.3' COVD CMONCED.IX
PORCH
7. 0• E1o.. A ( YONW/14.'
CC WALLS wood . 1—STORY X
PA
o
o Fh
DECK o
a, 5.5•BRICK
3 a' NO. 2009N20.1•.
Lli'
W M1o
3.6• 23.0'1 12.1' i--La./ 54
tt z i'5.
COVD
1 ..:1 CONC PATO BRICK O.a
NO ACCESS WALL Cr)
y 3; To lens M
s
Ix
f .6. 2.1 AREA
p_W
f
F/ _SCREENED
Y CONC
0 OD akilCONC ,o A F,00
N E
ti DRIVE N POOL a N
tel 10•. 21.1: 24.6'AGA1 R c'TO'R
1. o BLOCK ca2 -
D PATIO AC PEO WALLS
10'%10• JEA —I- BLOCKS PAD PAD
EASEMENT -
N 0 1'
25• EASEMENT
TINTCLOSUREUNE
11:1••• • -•• • -
CONC
4.*
1/2- HEADWALL 15•* OPEN DITCR
i/2' 25' EASEMENT FOR
IRON PIPE 13 REBAR DRAINAGE.UTIUTIES
CHR) LB 5488 AND SEWERS
SUBO(NSIOn BOUNDARY RACE
S 00'29 15 W 87.00' (R) CORNER
SEL VA NORTE' UNIT TWO
LOT
PLAT BOOK 40, PAGES 37 AND 37A
56
FLOOD LONE "A'. - AREAS DETERMINED TO BE OUTSIDE THE 02% ANNUAL CHANCE FLOOD PLAIN /MOOD ZONE -X (SHADE)' - AREAS OF 0.2% ANNUAL CHANCE FLOOD. AREAS OF IS ANNUAL
OH ANCE MTH AVERAGE DEPTHS OF LESS THAN I FOOT OR MTH DRAINAGE AREAS LESS THAN 1 SQUARE MILE; AND AREAS PROTECTED BY LEVEES FROM 131 ANNUAL CHANCE FLOOD.
E Y O ,
Q GENERAL NOTES:
I. BEARINGS ARE BASED ON PUT BOOK 3B. PAGE 946
2. STRUCTURE NO. 91OMN HEREON LIES MOAN FLOOD ZONE ALAS BEST DETERMINED
FROM F.E.M.A FLOOD MAPS PANEL NO.40) DATED 06- 0)-2013ASSOCIATEDSURVEYORSINC.
3. THIS IS1A
If
ACE
DEY
ONLY THE EXTENT OF GNOEJRQROU"° `°°"" PIPES AND
C3 URSDIC, K ANY, NOT OE HEION D.4.
THISSSURVEYTONAL
AND/OR
LEN
EGAL DESCRIPTIONSSER9TNE AREAS IF ANY, NOT TOUTED BY THIS SURVEY
Ell ".
LAND & ENGINEERING SURVEYS 5. THIS SURVEY BASED 014 LEGAL OEStOR EAS FURNISHED. THE MANTIC RECORDS MEREELI %
NOT SEARCHED BY THIS sIAR..ETOR FOR EASEANENT,, TILE, COVENANTS, B.RL.'S
RI
I- 3846 BLANDING BOULEVARD RES
6. THE HEEww UNE SSURMI ONNN,MAAY NOT INDICATE ETC.ACTOvwERsw.L JACKSONVILLE, FLORIDA 32210 T UNI ESS OTHER MSF STATED Al1 IRON PIPES FOUND NAVE NO IDEITWICA TION
iJ
904-771-6468
L SRL BURIL IDRESIN IC T ION LINE0S5V
CERTIFICATE OF AUTHORIZATION NO. LB 0005488 E BE BUILDING TIE PSN MRff'ESS[ONAL SIRVEYOR t NAPPER
6 II TN BETMEEN R RADIUS
E (C) COMPUTED FROM RECORD R) RECORD
N R/W RIGHT OF WAY
CW COVENANTS L INRESTRICTIONSRLSREGISTEREDLANDSIIVVEY
I HEREBY CERTIFY THIS SURVEY WAS DONE UNDER MY p COMI CAN NOT READ TYP) TYPICAL
DIRECT SUPERVISION AND MEETS THE MINIMUM TECHNICAL CONC CONCRETE o SET IRON PPE(P) CR RES AR
STANDARDS FOR LAND SURVEYING PURSUANT TO CHAPTER 5J-17.050 a COVD COVERED ASSOC SURV aR LB 548e
Ea
THROUGH 17.052• FLORIDA ADMINISTRATIVE CODE, CHAPTER 472, F.S. ET E CTTRIC
T1R
NSFORMER L PAD
X FOUND waw PLP[(IP) OR PIN
A _Jr., RAJACKSONVILLEELECTRICAUTHORITY
w fOl1ND CONCRETE MONUMENT (CM)
a L LENGTH Or ARC 6 aDss CLT OR DRILL HOLE
B LB LICENSED BUSINESS x—%— -8—%—B_B— Nllwp(NNc FENCE
R LS LICENSED SURVEYOR I-1—I--1— METAL FE/CE
BY:i A
E NLD NAIL L DISC MRE FENCEPENCE
CHAR S B. HATCHER FLORIDA CERTI CATE NO. 3 V DRB OFFICIAL RECORDS BOOKVH°K° na.4 cE
CHARLES L. STARUNG FLORIDA CER'FICATE NO. 4579
I
PCPCV
PPO
INTI
OOFF CURVEVE°s VOL UMEOVERHEAD DTIUTYANT
RAYMOND J. SCHAEFER FLORIDA CC' IFICATE NO. 6132 T PCC POINT DF CONFOUD CURVE I .PHO/NIRENENRISER
I PEO POOL EOU IPNENT PAD RA TOR METER
PI POINT OF INTERSECTION
O PRC PD INT 1W REVERSE CURVE g
VTIIJTY POLE
DIA NEIFRJOBNO. 72598 DATE 08—01-2018 N PRN PERNVVENT aEfEPExE NoaRNONT
SCALE: 1' = 30' DRAFTER MDC S Pis PPRR01F"ESSIONAL. ""LAND SUR VEYDR
ml-Y ANOMER
CFR MAL ANGLE
NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA UCENSED SURVEYOR AND MAPPER
GENERAC
Installation Guidelines
60 Hz Air-Cooled Generators
10 kW to 24 kW
MINNS
WARNING
do.A. Loss of life. This product is not intended to
be used in a critical life support application.
Failure to adhere to this warning could result
in death or serious injury. 000209b)
Register your Generac product at:
V VVW.GENERAC.COM
1-888-GENERAC
888-436-3722)
Para espanol, visita: http://www.generac.com/service-support/product-support-lookup
Pour le franpais, visiter : http://www.generac.com/service-support/product-support-lookup
AVE TRW MANUA 1
Fuel Conversion/Gas Connections
Section 5: Fuel Conversion / Gas Connections
Fuel Requirements and NOTE: All pipe sizing, construction, and layout must
Recommendations comply with NFPA 54 for NG applications and NFPA 58
or ICC IFGC for LP gas applications. Verify fuel pressure
NEVER drops below required specification once genera-
A DANGER tor is installed. See the NFPA website at www.nfpa.org
Explosion and fire. Fuel and vapors are extremely for further information regarding NFPA requirements.
flammable and explosive. No leakage of fuel is
Always contact local fuel suppliers or fire marshal to ver-permitted. Keep fire and spark away. Failure to do
ify codes and regulations for correct installation. Localsowillresultindeathorseriousinjury. (000192) codes will mandate correct routing of gaseous fuel line
piping around gardens, shrubs, and other landscaping.NOTE: NG is lighter than air and will collect in high
Piping strength and connections should be given specialareas. LP gas is heavier than air and will settle in low
consideration for installations in areas at risk for flooding,areas.
tornadoes, hurricanes, earthquakes, and unstable
LP gas should only use a vapor withdrawal system. This ground.
type of system uses vapors formed above liquid propane IMPORTANT NOTE: Use an approved pipe sealant orinthestoragetank.
joint compound on all threaded NPT fittings.
The unit will run on NG or LP gas, but has been factory-
configured to run on NG. NOTE: All installed gaseous fuel piping must be purged
and leak tested prior to initial startup in accordance withNOTE: Should the primary fuel need to be changed to local codes, standards, and regulations.
LP gas, the fuel system must be reconfigured. See Fuel
Conversion for instructions on converting the fuel sys- Fuel Conversiontern.
Proceed as follows to convert from NG configuration to
BTU Content LP gas.
Recommended fuels should have a BTU content of at See Figure 5-1 for fuel conversion knob (A) locations.
least 1,000 BTU/ft3 (37.26 MJ/m3) for NG; or at least The orange fuel conversion knob is located beneath the
2,500 BTU/ft3 (93.15 MJ/m3) for LP gas. fuel mixer on 10 kW units (B)and above the fuel mixer on
NOTE: BTU fuel content information is available from
13 kW-24 kW units (C).
fuel supplier. To select fuel type, turn fuel conversion knob towards
marked fuel source arrow until it stops. Fuel conversion
Fuel Pressure knob will rotate 180° and slide into mixer body when con-
Required fuel pressure for NG is 3.5-7.0 in water column
verting to LP gas.
0.87-1.74 kPa) at generator fuel inlet. Required fuel NOTE: The fuel selection (LP/NG) must be entered on
pressure for LP gas is 10-12 in water column (2.49-2.99 the controller during initial startup using the Install Wiz-
kPa) at generator fuel inlet. and navigation menu, or in EDIT menu under "Fuel
NOTE: The primary regulator for LP gas supply is NOT
Selection."
INCLUDED with generator.
O mita iii,/ 0
c` 1!'VIIIII .i
Cl::::1/1111611Alli'lkollid« 110,1UVA Muni Ilk::1.-1. - i
I.,-,Hv V.kit
001878
Figure 5-1. Fuel Conversion Knob Locations
installation Guidelines for 60 Hz Air-Cooled Generators 21
Fuel Conversion / Gas Connections
Fuel Consumption
Natural Gas*
Propane**
Generator
112 Load Full Load 112 Load Full Load
10 kW 2.86 / 101 3.60 / 127 0.97 / 3.66 / 36 1.48 l 5.62 1 54
13 kW 4.36 1154 6.37!225 1.54 / 5.83/ 56 2.45/ 9.28 /90
16 kW 5.15/ 182 6.94 /245 1.70/6.45 /62 2.99/ 11.32/ 109
20 kW 4.64/ 164 8.13/287 2.36 / 8.95 / 86 3.74/ 14.15/ 136
22 kW 5.75/203 8.66/306 2.53 / 9.57 / 92 3.90/ 14.77 / 142
24 kW 5.58/ 197 8.86 /313 2.28/ 8.61 /83 3.68 113.94 1134
Natural gas is in m3/h /ft3/h
Propane is in gal/h (LP) / L/h (LP) /ft3/h (LPV)
Values given are approximate
These are approximate values. Use the appropriate spec sheet or fuel data decal for specific values.
Verify gas meter is capable of providing enough fuel flow to include household appliances and all other loads.
NOTE: The fuel supply and pipe MUST be sized at 100% load BTU/h (Megajoule/h) rating.
Always see fuel data decal for the correct BTU/h or Megajoule/h, and required fuel pressures:
Natural Gas:
BTU/h = ft3/h x 1000
Megajoules/h = m3/h x 37.26
Liquid Propane Gas (Vapor):
BTU/h = ft3/h x 2500
Megajoules/h = m3/h x 93.15
Fuel Line Sizing
Selecting the correct size fuel line is crucial to correct
operation of the unit.
IMPORTANT NOTE: Generator inlet size DOES NOT
dictate size of gas pipe to be used!
For further information, see NFPA 54 for NG, or NFPA 58
or ICC IFGC for LP.
Measure distance from generator to fuel source on a low
pressure gas system.
IMPORTANT NOTE: Generator should be plumbed
directly from the fuel source through an appropri-
ately sized and correctly placed fuel pressure regula-
tor, not off the end of an existing low pressure
system.
Installation Guidelines for 60 Hz Air-Cooled Generators
22
Fuel Conversion/Gas Connections
Natural Gas Pipe Sizing
To determine correct NG pipe size, find the kW rating of NOTE: See Table B.3.2 in NFPA 54 or Table A.2.2 in the
generator in the left column, and trace to the right. The ICC IFGC, Equivalent Lengths of Pipe Fittings and
number to the right is maximum length (measured in ft / Valves for the correct values to be added to overall fuel
m) allowed for the pipe sizes on top. Pipe sizes are mea- piping length. Tables are based on schedule 40 black
sured by trade size diameter to include any fittings, pipe. If installing any other piping system, follow pipe siz-
valves (must be full flow), elbows, tees, or angles.in g chafor selected piping system.
Table 5-1. NG Pipe
Sizingrts
For 5-7 in Water Column For 3. 5-5 in Water Column
1.24-1.74 kPa) 0.87-1.24 kPa)
Pipe Size
in I mm)
Allowable Pipe Distances (ft/m)
0.51 13 0.75119 1 125 1.25/32 1.5138 0.75/19 1 125 1.25132 1.5138
10 kW 10/3.1 60/ 18.3 200/61 750/228.6 -20/6.1 60/18.3 175/53.3 -
13116 kW -10/3.1 55/16.7 200/60.9 450/ 137.1 -30/9.1 125/38.1 200/61
20 kW 10/3.1 35/ 10.7 140142.3 300191.4 -10/3.1 60/ 18.3 125/38.1
22/24 kW -10/3.1 30/9.1 115/35.1 250/76.2 -10/3.1 60/ 18.3 125/38.1
LP Gas Pipe Sizing
To determine correct LP gas pipe size, find the kW rating NOTE: Pipe sizes are from the outlet of the second
of generator in the left column, and trace to the right. The stage regulator to the fuel shutoff valve. Table is based
number to the right is maximum length (measured in ft / on schedule 40 black pipe. If installing any other piping
m) allowed for pipe sizes on top. Pipe sizes are mea- system, follow the pipe size charts for the selected piping
sured by trade size diameter to include any fittings, system.
valves (must be full flow), elbows, tees, or angles. See NOTE: Recommended minimum LP tank size is 250 gal
Table B.3.2 in NFPA 54 or Table A.2.2 in the ICC IFGC, (
946 L). Contact LP provider to correctly size LP tank to
Equivalent Lengths of Pipe Fittings and Valves for the generator. Vertical tanks, which are measured in pounds
correct values to be added to overall fuel piping length.or kilograms), are permitted if correctly sized for the gen-
erator. Do not connect generator to a 20 or 30 lbs LP
tank.
Table 5-2. LP Gas Pipe Sizing
For 10-12 in Water Column
2.49-2.99 kPa)
Pipe Size (in/mm) Allowable Pipe Distances (ft I m)
0.5113 0.75119 1 125 1.25 1 32
10 kW 30/9.1 175/53.3 400/ 121.9
13/16 kW
80/24.4 350/ 106.7 600/ 182.9
20122/24 kW
40/ 12.2 175/53.3 550/ 167.6
23
Installation Guidelines for 00 H?Air-Cooled Generators
Fuel Conversion/ Gas Connections
Installing and Connecting Fuel Lines
dDANGER441Explosionandfire. Fuel and vapors are extremely Iflammableandexplosive. No leakage of fuel isI.
permitted. Keep fire and spark away. Failure to do
Oil:
so will result in death or serious in u
I
P11
1ry' (000192)
ii` 11r1hihlvola- S.. . 1/
Mi
IMPORTANT NOTE: NG and LP gas areg y
tile substances. Strictly adhere to all safety proce-
dures, standards and regulationscodes, s g J
Fuel line connections should be made by a certified con- Figure 5-3. Fuel Shutoff Valve with Manometer Port
tractor familiar with local codes. Always use AGA-
approved gas pipe and a quality pipe sealant or joint Fuel shutoff valves available through an IASD:
compound. 1/2 in ball valve, part number OK8752
Verify capacity of NG meter or LP tank to provide suffi- 3/4 in ball valve, part number OK8754
cient fuel for both the generator and other operating 1 in ball valve, part number OK8184
appliances.1- 1/4 in ball valve, part number OL2844
Fuel Shutoff Valve 1-1/2 in ball valve, part number OL2845
See Figure 5-2. Thegenerator will require an external
Flexible Fuel Linemanualfuelshutoffvalve (A) on the fuel line.
NOTE: Fuel shutoff valve must be installed at a readily
See Figure 5-2. When connecting flexible fuel line (B) to
accessible location, and within 6 ft (1.8 m) of generator
generator, use a listed assembly meeting the require-
ments of ANSI Z21.75/ CSA 6.27—Connectors for Out-
fuel inlet. door Gas Appliances and Manufactured Homes or AGA-
approved flexible fuel line in accordance with local regu-
0 Oil
lations.
1 ..,^,i O i Flexible fuel line must not be connected directly to gener-
i•
O 1 re ator fuel inlet. Always connect flexible fuel line to an
s''-.= i approved gas fitting.
t..i_r The purpose of flexible fuel line is to isolate vibration from
A the generator to reduce possibility of a gas leak at one of
1I, the connection points. Installation of a flexible fuel line is
a fuelgas code and installation requirement.
NOTE: Follow all installation instructions and warnings
provided with the flexible fuel line. Do not remove any
DD1816 labels or tags. Flexible fuel line must be installed horizon-
Figure 5-2. Sediment Trap, Fuel Shutoff Valve with tally, and must be installed between fuel shutoff valve and
Manometer Port, and Flexible Fuel Line generator fuel inlet.
Figure 5-3 illustrates a fuel shutoff valve with a Sediment Trap
manometer port for making fuel pressure checks. This See Figure 5-2. Some local codes require a sediment
optional accessory fuel shutoff valve permits making trap (C). The fuel regulator connection has an integrated
pressure checks for diagnostic purposes without going sediment trap.
into the generator enclosure.The sediment trap must be cleaned periodically accord-
ing to local codes. See owner's manual for more informa-
tion,
24
Installation Guidelines for 60 Hz Air-Cooled Generators
6.
Fuel Conversion /Gas Connections
Checking Fuel Line Connections
Performing Fuel System Leak Test
Checking Fuel Pressure
ADANGER
Proceed as follows to check fuel pressure at fuel regula- Explosionamand
andfire.
expexplosive.
and
No
pornkaare
e of fuel is
for in the generator.permitted. Keep fire and spark away. Failure to do
1. Close fuel supply valve.
so will result in death or serious injury. (000192)
2. See Figure 5-4. Remove top fuel pressure test port
from fuel regulator and install fuel pressure tester All products are factorytested before shipping to verify
manometer). the performance and integrity of the fuel system. How-
ever, it is important to perform a final fuel system leak test
before starting the generator. The entire fuel system
I to regulator.
1/1*_,should be tested from supply 9
See Figure 5- 5. Perform a final fuel system leak test
6.--,..0.1 •,Iafter generator installation. The test will identify possible
w—i .! leaks at all connection points (A).e11%.. F iz,111.1..0.
111
It is best practice to perform a fuel system leak testiiiduringnormally-scheduled maintenance.
001807
O
1
Figure 5-4. Checking Pressure with Manometer 1=
it
3. Open fuel supply valve and verify fuel pressure is Q i
within specified values.
4. Record static fuel pressure: I111 Vii:
NOTE: Fuel pressure can also be tested at manometer
port on fuel shutoff valve shown in Figure 5- 2.111)
Via
NOTE: See fuel data decal or spec sheet for correct fuel
111'pressure specifications. Contact local fuel supplier if fuel
1pressureisnotwithinspecifications. iii5. Close fuel supply valve when completed. Keepjmanometerconnectedforfuturetestsofgenerator
1111:
1r'
while starting, running, and under loads. 0 e;
vivo I 004038
Figure 5-5. Connection Points to Leak Check
I
Inspect for leaks by spraying all connection points with a
non-corrosive gas leak detection fluid. The solution
should not be blown away or form bubbles.
25
Installation Guidelines for 60 Hz Air-Cooled Generators
LP Gas (Vapor) Installation (Typical)
0
o
o
l 0
4 H 0 00
O p .
G
j,;i;
il,0004 J
Iii. c 1.41 1-.
I m0 fit, 1. "(
1 ar 0 i
11111111111ftmeummum ji,
008966
Megajouleslh = m31h X 93.15
LPG BTU/h=ft3/h X 2500
isFuel data decal
EllMinimum distance from rear obstruction—see Distance Requirem
Manual fuel shutoff valve (pressure port optional)I away from fuel inlet.Must be located no more than 6 ft(1.83 m)
allPipe fittings (field supplied)
ents
Flexible fuel line to local gas codes.
mft 1.5 m) from generator. Local codes and regulatorVerifyminimumdistance
requirements for regulator vent according
Regulator should be a minim
manufacturer may have further clearance requirements.
el Clamp
Secondary fuel pressure regulator
IIII Manual shutoff valve
Fuel tank—sized
mary fuel pressure
regulator
operating
large enough to provide
required MJ/BTU for genorevorationt
FULL
111
lFuel
and ALL connected appliance loads. Be sure to correct for weather
Figure 5-7. LP Gas (Vapor) Installation (typical)
27
Installation Guidelines for 60 Hz Air-Cooled Generators
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $89.00
GSRS20-0068 Address: 2009 VELA NORTE CIR APN: 169506 1110 $89.00
MECHANICAL $85.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
GAS PIPING OUTLETS 455-0000-322-1000 1 $10.00
TANKS GAS OR LIQUEFIED PETROLEUM 455-0000-322-1000 200 $20.00
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R13727 $89.00
Printed: Thursday, October 8, 2020 4:01 PM
Date Paid: Thursday, October 08, 2020
Paid By: MIKE TROWBRIDGE
Pay Method: CREDIT CARD 384662986
1 of 1
Cashier: JJ
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R13727