Loading...
1240 Seminole Rd ACRS20-0136 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: NEIDHOLD SCOTT T 1627 BRICKELL AVE #2804 MIAMI FL 33129 COMPANY:ADDRESS:CITY:STATE:ZIP: A/C MASTERS HVAC INC 445 TRESCA ROAD #306 JACKSONVILLE FL 32225 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171937 0005 SELVA MARINA UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1240 SEMINOLE RD MECHANICAL RESIDENTIAL HVAC HVAC - 2 A/C, 2 AHU, 2 & 5 TON $15650.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT AC AND REFRIGERATION 455-0000-322-1000 7 $56.00 FURNACES AND HEATING 455-0000-322-1000 84000 $28.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.09 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $143.09 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/8/2020 PERMIT NUMBER ACRS20-0136 ISSUED: 10/8/2020 EXPIRES: 4/6/2021 MECHANICAL RESIDENTIAL HVAC PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD 2 of 2Issued Date: 10/8/2020 PERMIT NUMBER ACRS20-0136 ISSUED: 10/8/2020 EXPIRES: 4/6/2021 MECHANICAL RESIDENTIAL HVAC PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD DESCRIPTION ACCOUNT QTY PAID PermitTRAK $143.09 ACRS20-0136 Address: 1240 SEMINOLE RD APN: 171937 0005 $143.09 MECHANICAL $139.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 AC AND REFRIGERATION 455-0000-322-1000 7 $56.00 FURNACES AND HEATING 455-0000-322-1000 84000 $28.00 STATE SURCHARGES $4.09 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.09 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R13722 $143.09 Printed: Thursday, October 8, 2020 3:09 PM Date Paid: Thursday, October 08, 2020 Paid By: A/C MASTERS HVAC INC Pay Method: CREDIT CARD 384766103 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R13722 Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 19-0102 06/04/2020 1240 Seminole Road Riverside Homes of N. FL (904) 503-7055 LBishop@myriversidehome.com Revised Manual D duct layout for carriage house Riverside Homes of N. FL 4 4 4 ACRS20-0136 Bed 2 WIC 2 Bath 2 Bath 1 WIC 1 Bed 1 Living Room/Nook Kitchen Laundry Air Ha ndl er i s i n t he Hall way atti c ar ea. 141 cfm 137 cfm 141 cfm 141 cfm 144 cfm 25 cfm 30 cfm 27 cfm 35 cfm 23 cfm 7 " 7 " 14 " 7 " 7 " 149 cfm 7 " 226 cfm 4 " 12 " 4 " 4 " 4 " 4 " 7 " 420 cfm 320 cfm 14 " 10 " 10 " 12 " ACRS20-0136 2020-Jun-02 09:22:47 Right-Suite® Universal 2019 19.0.18 RSU13256 Page 1 ...iverside Homes\MISC\1240 Seminole Rd(Man D).rup Calc = MJ8 Front Door faces: SE RIVER870Job:Duct System Summary 06/02/20Date:Entire House By: A/C Masters HVAC, Inc. 445 Tresca Road, Suite #306, Jacksonville, FL 32225 Phone: 904.722.8995 Fax: 904.722.8944 Project Information Riverside HomesFor: 12276 San Jose Boulevard, Suite #120, Jacksonville, FL 32223 Phone: 904.503.7055 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0.16in H2O0.16 Available static pressure in H2O0.34in H2O0.34 Supply / return available pressure 0.214 / 0.126 in H2O in H2O0.214 / 0.126 Lowest friction rate in/100ft0.060in/100ft0.060 Actual air flow cfm928cfm928 Total effective length (TEL)ft285 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st2135.025.4VlFx0x04.00.0602230706hBath 1 st2140.025.6VlFx0x04.00.0602127648hBath 2 st1115.019.1VlFx0x07.00.0601271443421hBed 1-A st2140.025.3VlFx0x07.00.0601331493552hBed 2 st2135.017.3VlFx0x07.00.060137893235cKitchen st2135.019.6VlFx0x04.00.0602315540cLaundry st1115.013.6VlFx0x07.00.0601411383314cLiving Room/Nook st1115.012.9VlFx0x07.00.0601411383314cLiving Room/Nook-A st1115.011.3VlFx0x07.00.0601411383314cLiving Room/Nook-B st2145.033.9VlFx0x04.00.0601925583hWIC 1 st2140.029.4VlFx0x04.00.0602335822hWIC 2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 370 379 0.060 483 12.0 0x0 VinlFlx st1 st1 Peak AVF 928 928 0.060 868 14.0 0x0 VinlFlx ACRS20-0136 2020-Jun-02 09:22:47 Right-Suite® Universal 2019 19.0.18 RSU13256 Page 2 ...iverside Homes\MISC\1240 Seminole Rd(Man D).rup Calc = MJ8 Front Door faces: SE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb3 0x 2820 320 93.8 0.060 407 12.0 x0 0 VlFx rt1 rb1 0x 2260 200 105.7 0.060 415 10.0 x0 0 VlFx rt1 rb2 0x 4200 408 88.1 0.060 770 10.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 928 928 0.060 868 14.0 0x0 VinlFlx