Loading...
1878 Seminole Rd RESA20-0016 Addition, Reno PermitOWNER:ADDRESS:CITY:STATE:ZIP: MIDDLETON CATHERINE W 1878 SEMINOLE RD ATLANTIC BEACH FL 32233-5916 COMPANY:ADDRESS:CITY:STATE:ZIP: PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUINA PLACE ATLANTIC BEACH FL 32233 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172020 0522 SELVA MARINA UNIT 09 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1878 SEMINOLE RD RESIDENTIAL ADDITION SINGLE OR TWO FAMILY RESIDENTIAL ADDITION ADDITION AND RENOVATION $7000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/23/2020 PERMIT NUMBER RESA20-0016 ISSUED: 10/23/2020 EXPIRES: 4/21/2021 RESIDENTIAL ADDITION PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00 BUILDING PERMIT 455-0000-322-1000 0 $90.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.90 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.60 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $466.50 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 5 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 6 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Contractor. 2 of 2Issued Date: 10/23/2020 PERMIT NUMBER RESA20-0016 ISSUED: 10/23/2020 EXPIRES: 4/21/2021 RESIDENTIAL ADDITION PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $466.50 RESA20-0016 Address: 1878 SEMINOLE RD APN: 172020 0522 $466.50 BLDG SUBSEQUENT PLAN REVIEW FEES $125.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00 BUILDING $90.00 BUILDING PERMIT 455-0000-322-1000 0 $90.00 BUILDING PLAN REVIEW $45.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00 PUBLIC WORKS PLAN REVIEW $100.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE SURCHARGES $6.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.90 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.60 ZONING PLAN REVIEW $100.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL FEES PAID BY RECEIPT: R13919 $466.50 Printed: Friday, October 23, 2020 10:45 AM Date Paid: Friday, October 23, 2020 Paid By: PETER COALSON DESIGN FOR FLORIDA LLC Pay Method: CREDIT CARD 388918416 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R13919 RESA20-0016 10-2-2020 RESA20-0016 SHED 207 SQ.FT. RESIDENCE W/ ADDITION 3,639 SQ.FT.TOTAL IMPERMEABLE 40%COVERAGE % PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 TOTAL LOT 9100 SQ.FT. MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 106/21/20 JOB DESCRIPTION INDEX OF DRAWINGS 1 SITE PLAN 2 FLOOR PLAN KITCHEN PLAN 4 FOUNDATION PLAN PLAN 5 ROOF PLAN 6 ELEVATION 7 ELEVATION 8 ELEVATON 9 ELEVATION 10 GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS TO THE DESIGNER & OWNER PRIOR TO COMMENCING WORK. 2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORK. 3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE. FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 3,000 PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO THE DESIGNER & OWNER PRIOR TO COMMENCING WORK. 5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATION AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. 6. ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING NAILS, SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL. CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES, WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS AND CONNECTORS AS SPECIFIED HEREIN. 7. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED WITH DEVICE OF EQUAL OR GREATER CAPACITY. 8. THE INSTALLATION OF THE FASTENERS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. WIND BRACING (1ST AND 2ND FLOORS) 4'-0" X 8'-0" x 1/2" EXTERIOR GRADE PLYWOOD SIDING. NAIL 6" 0.C. FIELD AND EDGE. 19. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUIDES, OR TIE DOWNS. 214 SQ.FT.REMOVE WALKS LOT COVERAGE 2,275 SQ.FT. WALKS & DRIVE 1,451SQ.FT. 3 BUILDING SECTION / ENGINEERING ELECTRICAL / DETAILS & NOTES TYPICAL WALL SECTION & SPECIFICIATIONS 11 RENOVATE SINGLE STORY RESIDENCE. CONSTRUCT ADDITION ON WEST SIDE OF RESIDENCE. EXPAND EXISTING FLOOR PLAN INTO GARAGE AN FRONT PORCH UNDER EXISTING ROOF LINE. CREATE VAULTED CEILING IN MAIN LIVING AREA. UPGRADE ELECTRIC & PLUMBING INSTALL NEW HVAC SYSTEM. REPLACE ALL WINDOWS. INSTALL NEW BOARD & BATTON SIDING ON EXTERIOR REPAINT EXTERIOR & INTERIOR OF RESIDENCE. INSTALL NEW WOOD & TILE FLOORING PER ALLOWANCE. PROVIDE AND INSTALL WITH TOPS & APPLIANCES ELECTRICAL CODE WIND SPEED 130 MPH IMPORTANCE FACTOR 1 TYPE OF CONSTRUCTIO N OCCUPANCY CLASS Type V-B R-3 EXPOSURE C ENCLOSEDWIND EXPOSURE FLORIDA BUILDING CODE 6th Addition 2017 RISK LEVEL II BUILDING CODE REMODEL CATAGORY ALTERATION LEVEL 3 NATIONAL ELECTRICAL CODE 2014 GOVERNING CODES ENGINEERNG SPECIFICATIONS TAKE PRECEDENCE OVER ARCHITECTUAL WRITTEN DIMENSIONS TAKE PRESENDENCE OVER SCALED DRAWINGS NOTE: CONTRACT SET ENGINEERING FRONT PORCH 120 Sq.Ft. NET CHANGE TO IMPERMABLE AREA -67 SQ.FT 1" = 30' SCALE A 1 FOUNDATION PLAN 20.5' OPEN PORCH NEW 5' 24 ' 5' AD D I T I O N AD D T I O N REMOVE CONCRETE REMOVE WALK OPTIONAL FRONT PORCH INCLUDED IN COVERAGE CLCULATIONS PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 206/21/20 KITCHEN PLANSCALE 1/4" =1'-0" SCALE 1/8" = 1'-0" A 4 3 2 A4 A 4 1 A4 VA U L T E D A R E A KITCHEN PANTRY LAUNDRY GARAGE EXISTING CONCRETE SUNROOM LIVING DINNING SITTING FLOOR PLAN 6068 SGD 6068 SGD 6o 2 o W D RE F 12" COUNTER DW DW NEW WALL EXISTING WALL 4020 3050 3050 3050 3050 9'X7' OHD 6020 60 6 8 S G D 3050 20 3 0 20 3 0 NO CHANGE TO BEDROOM & MASTER BATH NEW SLIDING GLASS DOOR IN PLACE OF WINDOW NO CHANGES TO BEDROOM #3 C L 3 A5 2-6 2-6 TILE FLOOR WOOD FLOOR WOOD FLOOR WO O D F L O O R WOOD FLOOR wh GAS 2-8 2- 8 2-8 24"30"24"30"18" 2O 2O RE F DW DW 21"21" VENT ABOVE 4 SHELVES SH E L F SH E L F 36 " DINING KITCHEN LAUNDRY GARAGE SI D E B O A R D BY o W N E R 36" WOOD DECK 30" 20"16" 12 " HW 36 " PANTRY 12 " OVERHANG COUNTER HEIGHT HORIZONTAL PLANKS SIDES AND BACK 2X6 FRAME TILE FLOOR Skylight 5 A 4 5 NOTE: NEW WINDOWS AMERICAN CRAFTSMAN OR EQUAL CONTRACT SET GAS LINE TOTAL HEATED SQ FT. 2,214 2630 ADDITION FLOOR AREA 384 SQ.FT. SEE ENGONEERING SHEET FOR FRONT PORCH DETAILS PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 306/21/20 BUILDING SECTION 1/4" SCALE 5 A3 Duct to new room Spray Foam SPRAY FOAM 2X8 #2 y.p. 24" O.C. 5/8" ROOF Decking SPRAY FOAM R22 NEW 2X4 WALL FRAMING 16" O.C. SUM ROOM EXISTING WOOD TRUSS 2X10 #2 YP NAILED TO EXISTING TRUSS TOP CORD (BOTTOM CORD REMOVED) TIE 48" O.C. EXISTING 7/16" OSB WITH 30 YR SHINGLE (TYPICAL) EXISTING 2X4 WALL HVAC DUCT NEW MONOLITHIC FOUNDATION NEW MONOLITHIC FOUNDATION EXISTING SLAB ON GRADE ASSUME TRUSS BEARING ON WALL TO BE REMOVED 3'-0" NEW 2X4 WALL MONOLITHIC EDGE MONOLITHIC EDGE EXISTING STEM WALL CONSTRUCTION EXISTING STEM WALL FOUNDATION COMPACTED FILL EXISTING GRADE 1/2" DRYWALL CEILING 1X6 TRIM1X6 TRIM 2-2X10 HEADER CONTRACT SET SEE ENGINEERING SH S2.O1 NOTE: SEE ENGINEERING SH S2.O2 6" HOOK 6" HOOK R-13 INSULATION R13 INSULATION 1/2" CDX PLYWOOD SPRAY FO A M INSU L A T I O N R 2 2 INSULA T I O N R 2 2 SPRA Y F O A M SPRAY FOAM INSULATION R22 2X6 PT jOIST 2X6 SELECT PT DECKING 6X6 POST TYPICAL 2X6 #2 YP 2X6 #2 YP 2X4 #2 YP 3/4" PLYWOOD CEILING NAIL 3" O.C. 1/2" OSB 18" 2X6 PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 406/21/20 22' 0" 8 ' 9 " 5 A4 1 EXISTING SLAB NEW 4" CONCRETE SLAB NEW SLAB NEW SLAB NEW FOUNDATION 1 A4 2 A4 A4 FOUNDATION PLAN 1/8" SCALE A 1 5 A4 5 A4 FOUNDATION SECTIONS FIREPLACE HEARTH SECTION A4 3 A4 3 A 4 A4 2 1 A4 CONTRACT SET 4 A4 1 A4 FIREPLACE NEW CONCRETE HEARTH EXISTING CONCRETE SLAB MONOLITHIC EDGE EDGE AT GARAGE EDGE AT EXISTING SLAB ADDITIONAL HEATED AREA 610 SQ.FT. 5/8" BAR 48" O.C. TYPICAL SEE ENGINEERING SH SO.O1 NOTE: PETER COALSON DESIGN FOR FLORIDA LLC MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 51614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 1/8" SCALE A 1 ROOF FRAMING PLAN EXISTING TRUSS & CEILING VAULT EXISTING TRUSS & CEILING EXISTING TRUSS & CEILING EXISTING ROOF REMAINS EXISTING TRUSSES WITH 2X10 ATTACHED RIDGE LINE 2X8 RAFTERS 24" O.C. 06/21/20CONTRACT SET SEE ENGINEERING SH S2.O2 NOTE: NO INSULATION R-30 R-30 R-30 TOTAL AREA R-30 BEDROOM/ PANTRY/ LAUNDRY R-22 FOAM KITCHEN/ LIVING //SUNROOM NON INSULATED GARAGE ATTIC VENTILIATION A B C SEE ATTACHED ENGINEERING SHEETS FOR PORCH FRAMING DETAILS PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 6 VINYL SGD EASTH ELEVATION 1/4" SCALE A 1 EXISTING 5/8" PLYWOOD NAILED OFF 12" FIELD & 6" EDGE HARDIE 4X8 PANEL W/ 3" HARDI BATTONS APPLIED OVER NEW VAPOR BARRIER INSTALL ACCORDING MANUF. SPECEIFACTIONS TYPICAL EXTERIOR SIDING PRIME PAINT ALL NEW SIDING & TRIM . CAULK AS REQUIRED PRIME & PAINT ALL EXISTING FASCIA AND SOFFIT SEAL ALL NEW WINDOWS TO NEW VAPOR BARRIER. EXISTING (NEW) 30 YR ROOF SHINGLES VAULT NEW OHD NEW ENTRY DOOR 5/4" X 31/2" HARDI TRIM NEW VINYL WINDOW NEW VINYL WINDOW30503050305030504020 06/21/20CONTRACT SET 24'OPTIONSL FRONT PORCH PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 7 NORTH ELEVATION 1/4" SCALE A 1 EXISTING (NEW) 30 YR ROOF SHINGLES EXISTING 5/8" PLYWOOD NAILED OFF 12" FIELD & 6" EDGE HARDIE 4X8 PANEL W/ 3" BATTONS PPLIED OVER NEW VAPOR BARRIER 6020 RELOCATED DOOR EXISTING (NEW) 30 YR ROOF SHINGLES EXISTING (NEW) 30 YR ROOF SHINGLES NEW FLAT ROOF 5/4 X 31/2 " EXISTING FASCIA NEW VINYL WINDOW 3/4 X 3" BATTON 4X8 SHEET "HARDIE" [ANEL 06/21/20CONTRACT SET OPTIONAL PORCH SEE ENGINEERING SHEETS WOOD DECK PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 8 WEST ELEVATION 1/4" SCALE A 1 EXISTING 5/8" PLYWOOD NAILED OFF 12" FIELD & 6" EDGE HARDIE 4X8 PANEL W/ 3" BATTONS PPLIED OVER NEW VAPOR BARRIER NEW HARDIE APPLIED OVER NEW 1/2 " CDX EXISTING (NEW) 30 YR ROOF SHINGLES 6068 6068 6020 EXISTING 5/8" PLYWOOD NAILED OFF 12" FIELD & 6" EDGE HARDIE 4X8 PANEL W/ 3" BATTONS PPLIED OVER NEW VAPOR BARRIER EXISTING (NEW) 30 YR ROOF SHINGLES 06/21/20CONTRACT SET PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 9 SOUTH ELEVATION 1/4" SCALE A 1 EXISTING 5/8" PLYWOOD NAILED OFF 12" FIELD & 6" EDGE HARDIE 4X8 PANEL W/ 3" BATTONS PPLIED OVER NEW VAPOR BARRIER NEW SGD 5/4 X 3 1/2" TRIM EACH WINDOW TYPICAL EXISTING (NEW) 30 YR ROOF SHINGLES EXISTING 5/8" PLYWOOD NAILED OFF 12" FIELD & 6" EDGE HARDIE 4X8 PANEL W/ 3" BATTONS PPLIED OVER NEW VAPOR BARRIER 5/4 X 3 1/2" TRIM EACH BUILDING CORNER 06/21/20CONTRACT SET OPTIONAL PORCH SEE ENGINEERING SHEETS WOOD DECK PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD CONCRETE: 1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE. PLACEMENT SHALL BE IN ACCORDANCE WITH ACI 318. 2. ALL CONCRETE SLABS ON GRADE SHALL BE THE THICKNESS INDICATED ON THE DRAWINGS, OVER MINIMUM 6 MIL POLYETHYLENE VAPOR BARRIERS. SUCH SLABS SHALL BE REINFORCED WITH 6" X 6" #10/10 WELDED WIRE FABRIC LAPPED 8" AT EDGES AND ENDS. OR FIBERMESH REINFORCED CONCRETE 3. FILL UNDER CONCRETE SLABS SHALL BE CLEAN SAND OR ROCK AND FREE OF DEBRIS AND OTHER DELETERIOUS MATERIAL. FILL SHALL BE COMPACTED TO A DENSITY OF AT LEAST 95% OF STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D1557). 4. FOOTINGS SHALL BEAR UPON UNDISTURBED TREATED SOIL OR UPON SOIL COMPACTED TO AT LEAST 95% OF STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D1557: FOR A DEPTH OF AT LEAST THREE (3') FEET BELOW THE BOTTOM OF THE FOOTING. 5. WHERE SHOWN, CORES OF BLOCK MASONRY SHALL BE FILLED WITH GROUT OR PEA GRAVEL CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS AND REINFORCING STEEL AS INDICATED ON THE DRAWINGS. 6. REINFORCING STEEL SHALL BE ASTM A-615 GRADE 60 DEFORMED NEW BILLET STEEL CONFORMING TO ACI 301, ACI 315, ACI 318 AND CRSI MANUAL OF STANDARD PRACTICE LATEST EDITIONS. MINIMUM LAP SPLICES SHALL BE 48 BAR DIAMETER. 7. ALL CONTINUOUS VERTICAL AND HORIZONTAL REINFORCING STEEL IN FOOTING, BEAMS AND COLUMNS SHALL BE SPLICED A MINIMUM OF 48 BAR DIAMETERS OR 24", WHICHEVER IS GREATER. 8. CONCRETE COVER OF REINFORCING STEEL SHALL BE AS FOLLOWS: A. FOOTINGS: 3" BOTTOMS AND SIDES, 2" TOP. B. BEAMS 1 1 /2" BOTTOM, SIDES AND TOP. C. COLUMNS: 1 1/2". D. SLABS ON GRADE: 2" BOTTOM, 1" TOP. E. OTHERS PER ACI 318. 9. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A- 185, FREE FROM OIL, SCALE AND RUST AND PLACED IN ACCORDANCE WITH THE TYPICAL PLACING DETAILS, OF ACI STANDARDS AND SPECIFICATIONS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. 10. CONCRETE TESTING IF REQUIRED: TESTING LABORATORY SHALL PERFORM THE FOLLOWING TESTS ON CAST-IN-PLACE CONCRETE. A. ASTM C143 "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT CONCRETE." SLUMP RANGE SHALL BE 4-6 INCHES. B. ASTM C39 “STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS.” A SEPARATE TEST SHALL BE CONDUCTED FOR EACH CLASS, FOR EVERY 50 CUBIC YARDS (OR FRACTION THEREOF), PLACED PER DAY, REQUIRED CYLINDER (S) QUANTITIES AND TEST AGE AS FOLLOWS: 1 A T 7 D A Y S 2 A T 2 8 D A Y S ONE ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER THE DIRECTION OF THE ENGINEER, IF REQUIRED. IF 28 DAY STRENGTH IS ACHIEVED, THE ADDITIONAL CYLINDER CAN BE DISCARDED. WOOD FRAMING: 1. ALL WOOD FRAMING SHALL BE FABRICATED AND INSTALLED PER AITC AND TPI AND NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. IN ACCORDANCE WITH TABLE 2304.6.1 & 2304.10.1 (UNLESS OTHERWISE NOTED) 2. ALL STRUCTURAL WOOD MEMBERS SHALL BE SOUTHERN YELLOW PINE. UNLESS NOTED OTHERWISE. 3. UNLESS NOTED OTHERWISE THE FOLLOWING MINIMUM GRADES SHALL BE USED: A. STRUCTURAL LIGHT FRAMING SIZE 2" TO 4" THICK X 2" TO 4" WIDE; NO. 2 NON-DENSE OR BETTER. B. STUDS SIZE 2" TO 4" THICK X 2" TO 6" WIDE; NO. 2 DENSE OR BETTER. C. STRUCTURAL JOIST AND PLANKS SIZE 2" TO 4" THICK X 5" TO 8" WIDE; NO. 2 OR BETTER; 9" TO 12" WIDE; NO. 1 OR BETTER. D. LIGHT FRAMING SIZE 2" TO 4" THICK X 3" TO 4" WIDE; NO. 2 NON- DENSE OR BETTER. E. STUD GRADE S.P.F. CAN BE USED IN LIEU OF SOUTHERN YELLOW PINE FOR STUDS ONLY 4. PLYWOOD SHEETING SHALL BE APA STRUCTURAL 1., GROUP 1 SIZE AND SPAN RATING AS SHOWN ON THE DRAWINGS. NAIL WITH 8D NAILS (COMMON OR GUN) AT 6" O.C. ALONG PANEL EDGE AND 6" O.C. AT INTERMEDIATE SUPPORTS. 5. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH MASONRY, CONCRETE OR SOIL SHALL BE PRESSURE TREATED. 6. CONTRACTOR SHALL PROVIDE ALL FASTENING DEVICES AS SHOWN ON THE DRAWINGS AND AS NECESSARY AND SUITED FOR EACH APPLICATION. FASTENINGS SUBJECT TO MOISTURE SHALL BE HOTDIP GALVANIZED TO ASTM A-153-80, OR STAINLESS STEEL. 7. ALL METAL CONNECTIONS AND FABRICATIONS SHALL COMPLY WITH AISC SPECIFICATIONS. MANUFACTURED BY SIMPSON STRONG TIE. 8. SOLID BLOCK ALL JOISTS AND RAFTERS AT POINTS OF SUPPORT. 9. PREFABRICATED STRUCTURAL TRUSSES SHALL COMPLY WITH NFPA NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, TPI DESIGN SPECIFICATIONS FOR METAL PLATE-CONNECTED WOOD TRUSSES AND AITC 100. 10. ALL TRUSSES SHALL BE DESIGNED AND CERTIFIED BY THE TRUSS MANUFACTURER'S STATE OF FLORIDA REGISTERED ENGINEER. 11. CONTRACTOR SHALL CORRELATE WITH TRUSS MANUFACTURER TO ENSURE THAT ADEQUATE BEARING IS PROVIDED AT END REACTIONS OF ALL GIRDER TRUSSES. 12. TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS TO THE CONTRACTOR AND DESIGNER FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF DIMENSIONS, MATERIALS AND CONDITIONS. 13. BRACE TRUSSES DURING ERECTION AND AFTER PERMANENT INSTALLATION TO COMPLY WITH TPI BWT-76. 14. MICROLLAMS (OR EQUAL PARALAMS, LVL'S, ETC) SHALL BE USED WHERE SPECIFIED ON ENGINEERED PLANS AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ANY EDGES OR ENDS EXPOSED TO THE WEATHER SHALL BE PROTECTED BY THE INSTALLATION OF 36 GA., MIN., GALVANIZED STEEL FLASHING. 16. SPLICES IN MULTI -BOARD CONTINUOUS BEAMS SHALL BE ALLOWED FOR ONE BOARD ONLY PER SPAN AND ONLY AT THE QUARTER POINT OF THE SPAN, UNLESS SHOWN OTHERWISE. TYPICALWALL SECTION SCALE 3/4" SCALE 2X4#2 SPF STUDS 1/2" DRYWALL R-13 iNSULATION (2) 2X10 #2 YP HEADER 1X6 BAND 2X4 BACKING STRIP LIGHTING 1/2" PLYWOOD 1X3 BATTON 4X8 "HARDIE" PANEL HOUSE WRAP SEAL ALL PENETRATIONS 2X6 PT BASE PLATE 1X6 BASE MOLD 1/2" SHOE MOLD 1/2" CDX SHEETING 2X10 RAFTER 2X4 TRUSS TOP CORD (2) 2X4 TP #2 TOP PLATES EXISTING SOFFIT MATCH ASPHALT SHINGLES MONOLITHIC FOUNDATION 5/8" BAR 5/8" BAR 6" 4" CONCRETE SLAB SH 10 06/21/20CONTRACT SET SPECIFICATIONS SPECIFICATIONS SEE ENGINEERING SH S3.O1 NOTE: PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 11 06/21/20CONTRACT SET SEE ENGINEERING SH S3.O1 NOTE: SSSS S S S S S S S S SS SS R R R RR R R S R R 4" 4" S R S S S SSSS S S S S S S S S SS SS PRESSURE SWITCH R R R RR R R S R R 4" S R S S S GFI WP WP WPWP CATV CATV FL FL PERIMETER LINE OF FUTURE PORCH S S SUBPANEL MAIN PANEL DOOR OPERATOR GAS TANK ELECTRICAL PLAN 1/8" SCALE A 1 JUNCTION BOX CEILING FAN FL FAN LIGHT FLOOR OUTLET BRACKET LIGHT CEILING FIXTURE DUPLEX RECEPTICAL WALL SWITCH RECESSED CAN NOTE: PROVIDE FOR GFI PROTRCTION IN OUTLETS LOCATED IN KITCHEN / BATHROOM/ GARAGE & WATER PROOF OUTLETS ON EXTERIOR. ELECTRICAL INDEX Skylight VELUX SKYLIGHTS MODEL C08 WITH LIGHT FILTERING SOLAR OPERATED BLIND & CUSTOM FACTORY FLASHING GLAZING: LOW E3 ALUMNIUM CLAD INTERIOR FINISH PAINTED WOOD (WHITE) FACTORY INSTALLED BLIND TRACK 1/2" DRYWALL HEAD FLASHING LOW E GLAZING *NTS scale 1 A8 SKYLIGHT SECTIONS 4 1/2" 4 1/2" PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 12 06/21/20CONTRACT SET GFI A12 1 A12 2 A12 3 A12 4 REMOVE BOTOM CORD OF EXISTING TRUSS 2X4 #2 SPF STUDS 1/2" THREADED ROD TAIL OF EXISTING ENGINEERED TRUSS 2X10 #2 Y.P. ATTACHED TO TOP CORD OF EXISTING TRUSS 1/2" DRYWALL NAIL 5/8" EXISTING SHEETING 6" FIELD EDGE 2X4 #2 PTYP 12" MI N 2 0 " 12" MI N 2 0 " NEW MONOLITHIC FOUNDATION EXISTING 1/2" SHEETING EXISTING SOFFIT NEW 1/2" PLYWOOD SHEATING NAIL 6" O.C. FIELD & EDGE 4X8 HARDIE PANEL WITH 3" BATTONS 2X8 FASCIA 2X8 #2 Y.P. RAFTER FOAM INSULATION NEW MONOLITHIC FOUNDATION 1/2" DRYWALL 1/2" CEILING BOARD 5/8" PLYWOOD SHEATING NEW CONCRETE OVER EXISTING SLAB 1/2" DRYWALL 2X4 #2 SPF 1/2" DRYWALL 2X4 #2 PTYP 1/2" X 8" J BOLT 48" O.C. R 13 BATT INSULATION EXISTING 1/2" DRYWALL EXISTING TRUSS NEW 2-2X8 HEADER 2X4 WALL TO CEILING R 13 BATT INSULATION EXISTING TRUSS REMOVE INTERIOR 2X4 NON BEARING WALL ADD 1/2" BAR 32" O.C. 12"1/2" BENT BAR 48" O.C. WITH SET WITH 2 PART EPOXY EXISTING GARAGE SLABEXISTING FOUNDATION EXISTING 1/2" DRYWALL NEW 1/2" DRYWALL THICKNESS VARIES SECTION SECTION SECTION SECTION SHED 207 SQ.FT. RESIDENCE W/ ADDITION 3,639 SQ.FT.TOTAL IMPERMEABLE 40%COVERAGE % PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 TOTAL LOT 9100 SQ.FT. MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 106/21/20 JOB DESCRIPTION INDEX OF DRAWINGS 1 SITE PLAN 2 FLOOR PLAN KITCHEN PLAN 4 FOUNDATION PLAN PLAN 5 ROOF PLAN 6 ELEVATION 7 ELEVATION 8 ELEVATON 9 ELEVATION 10 GENERAL NOTES: 1.THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS TO THE DESIGNER & OWNER PRIOR TO COMMENCING WORK. 2.THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORK. 3.ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 4.SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE. FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 3,000 PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO THE DESIGNER & OWNER PRIOR TO COMMENCING WORK. 5.STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATION AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. 6.ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING NAILS, SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL. CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES, WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS AND CONNECTORS AS SPECIFIED HEREIN. 7.ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED WITH DEVICE OF EQUAL OR GREATER CAPACITY. 8.THE INSTALLATION OF THE FASTENERS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. WIND BRACING (1ST AND 2ND FLOORS) 4'-0" X 8'-0" x 1/2" EXTERIOR GRADE PLYWOOD SIDING. NAIL 6" 0.C. FIELD AND EDGE. 19.THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUIDES, OR TIE DOWNS. 214 SQ.FT.REMOVE WALKS LOT COVERAGE 2,275 SQ.FT. WALKS & DRIVE 1,451SQ.FT. 3 BUILDING SECTION / ENGINEERING ELECTRICAL / DETAILS & NOTES TYPICAL WALL SECTION & SPECIFICIATIONS 11 RENOVATE SINGLE STORY RESIDENCE. CONSTRUCT ADDITION ON WEST SIDE OF RESIDENCE. EXPAND EXISTING FLOOR PLAN INTO GARAGE AN FRONT PORCH UNDER EXISTING ROOF LINE. CREATE VAULTED CEILING IN MAIN LIVING AREA. UPGRADE ELECTRIC & PLUMBING INSTALL NEW HVAC SYSTEM. REPLACE ALL WINDOWS. INSTALL NEW BOARD & BATTON SIDING ON EXTERIOR REPAINT EXTERIOR & INTERIOR OF RESIDENCE. INSTALL NEW WOOD & TILE FLOORING PER ALLOWANCE. PROVIDE AND INSTALL WITH TOPS & APPLIANCES ELECTRICAL CODE WIND SPEED 130 MPH IMPORTANCE FACTOR 1 TYPE OF CONSTRUCTIO N OCCUPANCY CLASS Type V-B R-3 EXPOSURE C ENCLOSEDWIND EXPOSURE FLORIDA BUILDING CODE 6th Addition 2017 RISK LEVEL II BUILDING CODE REMODEL CATAGORY ALTERATION LEVEL 3 NATIONAL ELECTRICAL CODE 2014 GOVERNING CODES ENGINEERNG SPECIFICATIONS TAKE PRECEDENCE OVER ARCHITECTUAL WRITTEN DIMENSIONS TAKE PRESENDENCE OVER SCALED DRAWINGS NOTE: CONTRACT SET ENGINEERING FRONT PORCH 120 Sq.Ft. NET CHANGE TO IMPERMABLE AREA -67 SQ.FT 1" = 30' SCALE A 1 FOUNDATION PLAN 21' OPEN PORCH NEW 4.5' 2 4 ' A D D I T I O N A D D T I O N REMOVE CONCRETE REMOVE WALK OPTIONAL FRONT PORCH INCLUDED IN COVERAGE CLCULATIONS 4.5' CORRECTION CORRECTION 10/09/2020 PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUIA PLACE ATLANTIC BEACH FLORIDA TELEHONE 904-759-2556 FLORIDA CERTIFICATION CBC 060273 MIDDLETON RESIDENCE 1878 SEMINOLE ROAD SH 206/21/20 KITCHEN PLANSCALE 1/4" =1'-0" SCALE 1/8" = 1'-0" A 4 3 2 A4 A 4 1 A4 V A U L T E D A R E A KITCHEN PANTRY LAUNDRY GARAGE EXISTING CONCRETE SUNROOM LIVING DINNING SITTING FLOOR PLAN 6068 SGD 6068 SGD 6 o 2 o W D R E F 12" COUNTER DW DW NEW WALL EXISTING WALL 4040 3050 3050 3050 3050 9'X7' OHD 6020 6 0 6 8 S G D 3050 2 0 3 0 2 0 3 0 NO CHANGE TO BEDROOM & MASTER BATH NEW SLIDING GLASS DOOR IN PLACE OF WINDOW NO CHANGES TO BEDROOM #3 C L 3 A5 2-6 2-6 TILE FLOOR WOOD FLOOR WOOD FLOOR W O O D F L O O R WOOD FLOOR wh GAS 2-8 2 -8 2-8 24"30"24"30"18" 2O 2O R E F DW DW 21"21" VENT ABOVE 4 SHELVES S H E L F S H E L F 3 6 " DINING KITCHEN LAUNDRY GARAGE S I D E B O A R D B Y o W N E R 36" WOOD DECK 30" 20"16" 1 2 " HW 3 6 " PANTRY 12 " OVERHANG COUNTER HEIGHT HORIZONTAL PLANKS SIDES AND BACK 2X6 FRAME TILE FLOOR Skylight 5 A 4 5 NOTE: NEW WINDOWS AMERICAN CRAFTSMAN OR EQUAL CONTRACT SET GAS LINE TOTAL HEATED SQ FT. 2,214 2630 ADDITION FLOOR AREA 384 SQ.FT. SEE ENGNEERING SHEET FOR FRONT PORCH SECTION M A X 4 '-6 " M A X 4 '-6 " 24' CORRECTIONS10/9/2020 RESA0-0016 SLOPES TO STREET SLOPES TO STREET TOILET PARKING MATERIAL STORAGE DUMP MIDDELTON RESIDENCE 1878 SEMINOLE ROAD ATLANTIC BEACH FL. SITE MANAGEMENT PLAN SILT FENCE AS REQURED