2233 Seminole Rd Unit 12 ACRS20-0274 PermitOWNER:ADDRESS:CITY:STATE:ZIP:
PETWAY BRETTE 1535 UPLAND AVE BOULDER CO 80304
COMPANY:ADDRESS:CITY:STATE:ZIP:
SNYDER HEATING & AIR P O BOX 16826 JACKSONVILLE FL 32245
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169519 0124 OCEAN VILLAGE ONE
CONDO
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
2233 SEMINOLE RD UNIT 12 MECHANICAL RESIDENTIAL
HVAC
HVAC - 1 A/C, 1 AHU, 2.5
TON $5310.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
AC AND REFRIGERATION 455-0000-322-1000 2.5 $16.00
FURNACES AND HEATING 455-0000-322-1000 30000 $24.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/23/2020
PERMIT NUMBER
ACRS20-0274
ISSUED: 10/23/2020
EXPIRES: 4/21/2021
MECHANICAL RESIDENTIAL HVAC
PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
TOTAL: $99.00
2 of 2Issued Date: 10/23/2020
PERMIT NUMBER
ACRS20-0274
ISSUED: 10/23/2020
EXPIRES: 4/21/2021
MECHANICAL RESIDENTIAL HVAC
PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $99.00
ACRS20-0274 Address: 2233 SEMINOLE RD UNIT 12 APN: 169519 0124 $99.00
MECHANICAL $95.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
AC AND REFRIGERATION 455-0000-322-1000 3 $16.00
FURNACES AND HEATING 455-0000-322-1000 30000 $24.00
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R13920 $99.00
Printed: Friday, October 23, 2020 10:59 AM
Date Paid: Friday, October 23, 2020
Paid By: SNYDER HEATING & AIR
Pay Method: CREDIT CARD 388920352
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R13920
Meghanical Permit Application
City of Atlantic Beach Building Department
800 Seminole Rd, Atlantic Beach, FL32233
P h o n e : ( 9 04 ) 247 5826 E m a i | : n tll riif*ji:lJl-gj3i{-b.-i1i
IoB ADDRE 55' hLZZ .1 :no Io AJ # I Z- PROJECT VALUE 5 <3 fo.co
D Condenser Only
Tons per Unit
I air Handling IJnit & Condenser
Seer Rating (REQUIRED)
Seer Rating (REQU]RED/ l'1
.LtKnrpmcEMENT AtR coNDrnoNrNG & HEATTNG sysrEM tNsrALLATroN ARt # (REeutREDj ?qq6?6'(
' I Air'Handling Equipment Only t] Condenser Only * Air Handting lJnit & Condenser
Air Conditioning: Unit Quantity t Tons per Unit 7.5
Heat:
Duct Systems:
l-leat:
Duct Systems:
Irrnr PREVENTToN
Fire Sprinkler System
Fire Standpipe 'I
Underground Fire Main
Fire Hose Cabinets
Commercial Hoods
Fire Suppression Systems
Irrne PLAcES
Quantity
Quantity
Value
Quantity
Quantity
Quantity
(Requires 3 sets of plarrs)
(Requires 3 sets of plans)
(Requires 3 sets of plans)
(Requires 3 sets of plans)
{Requires 3 sets of plans)
(Requires 3 sets of plans)
Prefabricated Fireplace
Gas Piping Outlets
LIALL OTHER GAS PIPING
Quantity of Outlets
ll Vented Wall Furnaces
# Water Heaters
(Qtv1--
BTUs
BTUs
x MTScELLANEOUS:
Automobile Lifts
Bo ile rs
Elevators/Esca lators
Heet Fvr^henoer
Pumps
Ref rige rator Condenser
Solar Collection Systems
Tanks (gallons)
Wells
**ALL INFORMATION
HIGHLIGHTED IN
GRAY IS REQUIRED.
PERMIT #:
f] new AIR coNDtroNrNG & HEATTNG sysrEM rNsrALLATroN ARt # (REeutRED) _
J Air Hondling Equipment Anly
Air Conditioning: Unit Quantity
Unit Quantity _ BTUs per Unit
Total CFM
Unit Quantity \ BTU's Per Unit ?9OOD
Total CFM
OTHER:
Permit becomes void if work.does not commence within a six month period or work is suspended or abandoned for six months. I hereby
certify that I have read this-application and know the same to be true and correct. All provisions of laws and ordlnances governing this
'worl< wili be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or
local law regulation constructi6n or the performance of construction.
owner Nu^", Broflq, /af,nov Phone Number: -?llL'63?6
(l , / n . \ /. \ -Mcchanical Company: _ Otfrce Phone: (3o-UJ-{!aAW0 _Fax80j(o4r't@
Co. Addrcss ; 5.,,-Lc:orrt.rilla State:?t- Zip: jvV15
License Holder:crtification/Rcgistration # WClSllbo+
Naterized Signature of License Holder
Thc fr-.rregoing inslrunre'rrt was ackrro+rledged befoie me t
countv o"f 6wA is\day of
-E4Pt=. ,-, 20 AD in the state of Florida,
_$du^ r.stt_
----"-u-_v-_-'** Cour*rbn#G0$tgS2
Signature of Notary Public
[ ] Personally.Known OR I I Produced Identification?I4{S E4rlr€.xry2t,az{-sorFlr Edtddf|ntg0dg.$ldrys.nlo.3
Type of ldentification:
Updored I 0/9/18
ACRS20-0274
ffiww$$$$mmWm w$ Wx-m#wm* ffimK$ffimffi
AHRI Certified Reference
AftRl Type : HRCU-A-CB
Series : DZ14SN
Number : 7998784b
(Split System: Heat Pump with
Date : 09-02-2020
Remote Outdoor Unit-Air-Source)
Model Status : Active
Outdoor Unit Brand Name : DAIKIN
Outdooi Unit Model Nunrber (Condenser or S.ingle Package) . DZ1aSN030iAj
Indoor Unit Model Number (Evaporator and/or Air Handler) : ARUF31B144.
The manifacturer of this DAIKIN product is responsible for the rating of this system combination
Rated as {ollows in accordance with the latesteditron of AHR] 21Ol240 with Addenoum
Arr-Conditioning & Air-Source Heat Pump Equipment and subject to rating accuracy_by-I
Cooling Capacity (A2) - Single or High Stage (95F), btuh . 28000
SEER 14.00
1, Performance Rating of Unitary
AHRI-sponsored. independent, third party testing:
EER (A2) - Single or High Stage (95F) : 12.00
Heating Capacity lntZi- Singte or High Stage (47F):27800
fISPF (Region lV) : 8.20
t"Active" Model Status are lhose that an AHRI Ceitificationirogram Participant is curently producing AND selling or offering for sale; OR new models that are Detng
marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certificataon Program Parlicipant is no longer producing BUT is still
or offering for sale
J.
DISCLAIM ER
AHRI does not endorse the product(s) Iislqd on this Certificate and makes no represeitations, warianties or gubrantees a.s'to, and assumes no responsibility for.
the product(s) listed on this Certificate- AHRI expressly disilaims all liabiliiy for damages of any kind arising out ol the use or performance of the product(s), or the
unauthorized alteratiolt of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at r\'., .r. sttr;{j" { rt(}r\ .,! r}:.
If :H,il3,"t"T?,'J'::L:',, are proprietary products or AHRI. This certiricare shatr onty be used tor indivrduat, personat anct ffi ffi"affiffiU
::ii',i:T?"T:TilTJii?ilf;l;lil,"Llliilli,X'Jffi:;:lf'::f,Iil,iil,J"l#lij'"iiii;3ii."Jiii,i'#',i"J;".1iTffillffii'' ffiM mm *ffi
pcrsonal and confidential referencc.
CERTIFICATE VERIFICATION
Thc itlformation for thd nrodel cited on this certificatc can be verified at $n,w.ahrid;fecio{}.{}{&, click on "Vririiy Cr.rrtili*;*1*" link
and enter the AHRI Certified Reference Number and the date on which the certificate was issued.
whrch rs listed atove. and the Certificate No.. which is listed at bottom right.
@2020Air-Conditioning, Heating, and Refrigeratiori lnstitute CERTIFICATE NO,:
.{ {ii,c$il$tTtoNlNG, t{EATING.
& HEf Ri{itrRAlrON ti!iiTtTUTE
.1 I ,, i i,. :.. ii!.r'
1 32435401 026498 1 00