1356 Linkside Dr RESA20-0011 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP:
Andrew McCrary 1356 LINKSIDE DR ATLANTIC BEACH FL 32233-4388
COMPANY:ADDRESS:CITY:STATE:ZIP:
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
172374 5145 SELVA LINKSIDE UNIT 01
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1356 LINKSIDE DR
RESIDENTIAL ADDITION SINGLE
OR TWO FAMILY RESIDENTIAL
ADDITION
ENCLOSING PATIO AND
ADDING A BATHROOM $47850.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
2 PUBLIC WORKS POST CONSTRUCTION TOPO SURVEY INFORMATIONAL
Notes:
If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to
retention area and retention overflow must run to street.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/27/2020
PERMIT NUMBER
RESA20-0011
ISSUED: 10/27/2020
EXPIRES: 4/25/2021
RESIDENTIAL ADDITION PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00
BUILDING PERMIT 455-0000-322-1000 0 $290.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $145.00
PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $8.40
STATE DCA SURCHARGE 455-0000-208-0600 0 $5.60
ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00
TOTAL: $774.00
3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
5 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL
Notes:
Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of-
way for construction parking.
6 PUBLIC WORKS RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site. Cannot raise lot elevation.
7 PUBLIC WORKS DECKING REMOVED INFORMATIONAL
Notes:
All old decking and debris must be removed from job site by Contractor.
2 of 2Issued Date: 10/27/2020
PERMIT NUMBER
RESA20-0011
ISSUED: 10/27/2020
EXPIRES: 4/25/2021
RESIDENTIAL ADDITION PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $774.00
RESA20-0011 Address: 1356 LINKSIDE DR APN: 172374 5145 $774.00
BLDG SUBSEQUENT PLAN REVIEW FEES $125.00
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00
BUILDING $290.00
BUILDING PERMIT 455-0000-322-1000 0 $290.00
BUILDING PLAN REVIEW $145.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $145.00
PUBLIC WORKS PLAN REVIEW $100.00
PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00
STATE SURCHARGES $14.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $8.40
STATE DCA SURCHARGE 455-0000-208-0600 0 $5.60
ZONING PLAN REVIEW $100.00
ZONING REVIEW SINGLE AND TWO FAMILY
USES 001-0000-329-1003 0 $100.00
TOTAL FEES PAID BY RECEIPT: R13957 $774.00
Printed: Tuesday, October 27, 2020 2:33 PM
Date Paid: Tuesday, October 27, 2020
Paid By: Andrew McCrary
Pay Method: CREDIT CARD 390054115
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R13957
1
IMPORTANT
PERMIT AND INSPECTION NOTES
BUILDING.
1. The City Sea Turtle Protection Ordinance applies where land either has frontage on Beach Avenue, the
Cloister Condominium, or is located eastward of Seminole Road from 20th Street northward to the City Limits.
2. No fill dirt can be delivered without prior approval from Public Works. Per COAB, 24-68.
3. The bottom of all foundation footings must be minimum 12 inches below existing grade, per COAB, 24-68
and FBC-B, Section 403.1.4. Site conditions may require footings to be deeper or higher above finished grade.
Please review COAB Bulletin 1-16 to ensure minimum Finished Floor Elevation (FFE).
4. Fill dirt inside foundation walls must be compacted in 8-inch lifts, per FBC-R506.2.1. Please submit
compaction tests, from a third-party testing agency, for every 16 inches of fill or fraction thereof.
5. At Final Inspection, a 6-inch clearance between exterior wall coverings and final grade (top of sod or mulch)
will be required, per FBC-R318.7. Please plan FFE and lot grading accordingly.
6. Where questionable soils are found, during inspection, soil and compaction tests may be required, per FBC-
R401.
7. Please provide a form-board or stem wall elevation form, from a licensed surveyor, for slab inspection.
8. Please review COAB Bulletin 2-18 to determine if a survey with setbacks and dimensions to property lines is
required for slab inspection.
9. The placement and protection of steel reinforcement (Rebar) must comply with FBC-R606 (Masonry) and
R608 (Concrete), including required Standard Hooks at top and bottom of vertical rebar.
10. Inspections:
a. In-Progress Inspections are required for Exterior Siding and Window and Door Inspections and
should be scheduled for the first day of work.
b. A Scratch-Coat Inspection is required for stucco work. If you intend to apply a double-up, brown-
coat, please call the Building Department to schedule a same-day Scratch-Coat Inspection.
c. All roofing projects require an In-Progress Inspection, Residential and Commercial.
d. The roof must be complete and the building dried in before scheduling rough trades inspections.
11. The joint tape for ZIP Board products is considered the dry-in or House Wrap for the building and must be
inspected before covering over. All holes and penetrations in the sheathing and overdriven nails must be
sealed.
12. Please post the building permit documents in a conspicuous location, before start of construction,
including the Building Permit, Notice Of Commencement (NOC), and Construction Site Management Plan. The
Police Department may review the management plan for compliance and parking.
13. Blocking any sidewalk or street is prohibited without prior approval from the Police Department and City
Manager.
2
14. All work must match the approved plans. All changes to the approved plans must be re-submitted for plan
review and approved before it can be inspected. Building inspectors are not authorized to approve changes to
the approved plans in the field. (See Mechanical)
15. Where excavation is required for new construction, the provisions of FBC-B, Section 3307 will apply,
including a 10-Day prior notice to adjoining property owners and protection of adjoining properties. Where
the excavation exceeds 24 inches, temporary retaining walls must designed by the Engineer Of Record (EOR)
and installed during or immediately after excavation.
EXISTING BUILDINGS – REMODELS, RENOVATIONS, ADDITIONS, CHANGE OF OCCUPANCY.
1. Existing buildings are reviewed and permitted under the Florida Building Code-Existing Buildings (FBC-
EB). The applicant must specify the method of compliance, per FBC-EB 301.1, and include that
information on the plans, with the Design Criteria and Code Analysis.
2. The requirements for the method specified will be found in the corresponding FBC-EB Chapter.
3. When it is discovered during construction that the Compliance Method is not correct, or the project
has expanded into another Compliance Method, revised plans will be required to update the Permit.
No inspections will be conducted until the approved revisions are on site.
4. Any wall opened by removing interior or exterior wall coverings is considered a Work Area, and current
provisions for Energy Conservation, including weatherproofing and insulation will apply.
5. Building inspectors are not authorized to approve changes to the approved plans in the field.
ROOFING.
a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing
Inspection is approved.
b. All roofing projects require an In-Progress Inspection.
c. Sheathing installation and replacement guidelines per APA.
d. Underlayment must conform to FBC-R Table 905.1.1
e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F
ELECTRICAL.
1. Electrical work must comply with the provisions of the 2014 NEC.
2. Anti-Oxidant Compound is required on all exterior aluminum wiring connections, unless the Listing
Approval Documents for the conductors and the termination points, at each end, specifically allow
connection without the compound. (Three documents will be required)
PLUMBING.
1. Water supply and drain pipes must be insulated outside of conditioned areas, per FBC-R, P2603.5.
2. Where the entire sanitary drainage system is replaced, the existing building drain and building sewer
3
must be internally examined to verify proper size and slope and that piping is not broken or obstructed,
per FBC-R, P2502.1.
3. COAB requires an additional sewer cleanout near the sewer tap with a T-1 concrete box for protection.
4. Water service piping must be properly supported and covered by a minimum of 12 inches of soil, per
FBC-R, P2604.3.
MECHANICAL.
1. All equipment and duct work must match the approved plans and Energy Sheets.
The Manual S is the approved duct plan, and the as-built duct work must match the approved plans, or
a revised Manual S or equivalent must be submitted for review. An equivalent must include duct and
trunk layout and sizes, available static pressure, actual air flow, and total effective length, signed by the
Mechanical Contractor with State License Number.
FUEL GAS.
1. Fuel gas systems from the regulator to the appliances must comply with the FBC-Gas.
2. LP gas storage systems and outside piping must comply with NFPA 58.
3. All underground gas piping and tubing must be buried with 12-inches of cover.
4. CSST gas piping must comply with the manufacturer’s installation instructions and terms of approval.
4
01/23/20, 02/13/20
RESA20-0011
Revision Request/Correction to Comments **ALL INFORMATION
HIGHLIGHTED IN
GRAY IS REQUIRED. City of Atlantic Beach Building Department
800 Seminole Rd, Atlantic Beach, FL 32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________
Revision to Issued Permit OR Corrections to Comments Date: ________________
Project Address: ____________________________________________________________________________________
Contractor/Contact Name: ____________________________________________________________________________
Contact Phone: ______________________________ Email: _________________________________________________
Description of Proposed Revision / Corrections:
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes.
(printed name)
Will proposed revision/corrections add additional square footage to original submittal?
No Yes (additional s.f. to be added: _____________________________)
Will proposed revision/corrections add additional increase in building value to original submittal?
No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation)
*Signature of Contractor/Agent: _______________________________________________________
__________________________________________________________________________________________________
(Office Use Only)
Approved Denied Not Applicable to Department Permit Fee Due $_______________
Revision/Plan Review Comments_______________________________________________________________________
__________________________________________________________________________________________________
Department Review Required:
Building _____________________________________________
Planning & Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities _____________________________________________
Public Safety Date
Fire Services Updated 10/17/18
1356 Linkside Dr. Atlantic Beach, FL
9/1/2020
RESA20-0011
Will Cronin
904-566-7993 KandcConstructioninc@gmail.com
Will Cronin
Add bathroom to downstairs living area. Enclose porch area on back of house.
RESA20-0011