Loading...
FL12098_R8_II_2019-08-17 CCRR-0258 G103959975 revision - final (formating)Code Compliance Research Report  CCRR‐0258    Issue Date: 10‐31‐2016  Revision Date: 06‐28‐2019  Renewal Date: 10‐31‐2019  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017      DIVISION: 07 00 00 ‐THERMAL AND MOISTURE PROTECTION  Section: 07 45 00 – Fiber‐reinforced Cementitious Panels    REPORT HOLDER:  Nichiha USA Inc.  6465 E. Johns Crossing, Suite 250  Johns Creek, Georgia 30097  www.nichiha.com    REPORT SUBJECT:  NichiProducts™ Fiber‐Cement Siding Products    1.0 SCOPE OF EVALUATION  1.1 This Research Report addresses compliance with the  following Codes:   2018, 2015, and 2012 International Building Code® (IBC)   2018, 2015, and 2012 International Residential Code®  (IRC)    2017 and 2014 Florida Building Code – Building (FBC) and  Residential (FRC) (including HVHZ) (see Section 9)   2016 and 2013 California Building Code – Building (CBC)  and Residential (CRC) (see Section 9)  NOTE: This report references 2018 Code sections. Section  numbers in earlier editions may be different.  1.2 The NichiProducts™ siding products described in this  report have been evaluated for the following properties (see  Table 1):   Physical properties    Wind resistance   Surface burning characteristics   Noncombustibility   Weather protection   Fire‐resistance‐rated construction  1.3 The  NichiProducts™  siding  products  have  been  evaluated for the following uses (see Table 1):   Use as an exterior wall covering in accordance with IBC  Section 1405.16 and IRC Section R703.10.   Use on exterior walls in Types I, II, III, and IV construction   Use on exterior walls permitted to be of Type V  construction.   Use on walls required to be of fire‐resistance‐rated  construction.    2.0 STATEMENT OF COMPLIANCE    The NichiProducts™ siding products recognized in this report  comply with the Codes listed in Section 1.1, for the properties  stated in Section 1.2, and uses stated in Section 1.3, when  installed as described in this report, including the Conditions  of Use stated in Section 6.  3.0 DESCRIPTION  3.1 NichiProducts™ Fiber Cement Siding Products:  The siding products are used for lap and panel siding. A  description  of  the  siding  products,  their  dimensions  and  their intended application is in Table 2.  4.0 PERFORMANCE CHARACTERISTICS    4.1  Physical Properties: The siding products comply with  ASTM  C1186,  Type  A,  Grade  II,  in  accordance  with  IBC  Section 1403.10 [1404.10] and IRC Section R703.10.    4.2  Wind  Resistance:  The  maximum  allowable  wind  pressure  for  each  of  the  siding  products  is  described  in  Tables 3, 4, 5 and 6.     4.3  Surface  Burning  Characteristics: The siding products  have a flame spread index of 0 and a smoke‐developed index  of 0, when tested in accordance with ASTM E84.     4.4  Noncombustibility: The  siding  products  are  noncombustible building construction materials complying  with IBC Section 703.5 as determined by testing in  accordance with ASTM E136.    4.5  Weather Protection:  Siding products are installed in  accordance with Section 5.2 of this report.        Code Compliance Research Report CCRR‐0258  Page 2 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 4.6  Fire‐resistance‐rated  Construction:  Fire‐resistance‐ rated construction is outside the scope of this report.  5.0 INSTALLATION  5.1 General:   The siding must be installed in accordance with the Nichiha  USA Inc., published installation instructions, the applicable  Code,  and  this  Research  Report.  A  copy  of  the  manufacturer’s instructions must be available on the jobsite  during installation.  5.2  Application:     Under the IBC, the siding products must be installed over a  water‐resistive  barrier  complying  with  Sections  1403.2  [1404.2]  and  1402.5  [1403.5]  and  must  be  attached  as  described for the specific assembly in Tables 3, 4, 5, 6, 7, and  8.    Under the IRC, the siding products must be installed over a  water‐resistive barrier complying with Section R703.2.  Lap  siding and panel siding may be installed as described in Table  R703.3(1), for areas in which the design pressure does not  exceed 30 pounds per square foot and the mean roof height  does not exceed the limits in Table R703.3.1, or as described  in  Tables  3  through  6.  For  conditions  that  exceed  these  limits, the panels must be installed as described in Table 9.  6.0 CONDITIONS OF USE   6.1 Installation must comply with this Research Report, the  manufacturer’s published installation instructions, and the  applicable Code.  In the event of a conflict, this report  governs.     6.2  When  allowable  wind  speed  is  determined  in  accordance with Table 3, the allowable wind speed must be  equal to or greater than the design wind speed calculated in  accordance with the applicable Code.    6.3 When  the  wall  construction  includes  a  combustible  water‐resistive barrier and is required to be of Type I, II, III,  or IV construction, use of the siding products is limited to a  maximum 40 feet in height above grade plane except under  the 2018 [2015] IBC where data has been presented to the  building  official  demonstrating  compliance  with  the  Exception to Section 1402.5 [1403.5].     6.4 The  NichiProducts™  siding  products  are  produced  under a quality control program with inspections by Intertek  Testing Services NA, Inc.  7.0 SUPPORTING EVIDENCE  7.1 Reports of tests in accordance with ASTM C1186, ASTM  E84, ASTM E136, and ASTM E330.   7.2 Data in accordance with the ICC‐ES Acceptance Criteria  for Fiber Cement Siding Used as Exterior Wall Siding (AC90),  dated June 2012 (editorially revised September 2015).   7.3 Intertek Listing Report "Nichiha NichiProducts™ Fiber  Cement  Siding  Products"  on  the Intertek  Directory  of  Building Products.   7.4 Documentation of an Intertek approved quality control  system for the manufacturing of products recognized in this  report.  8.0 IDENTIFICATION    The NichiProducts™ siding products are identified with the  Nichiha USA Inc., name, and address, the product name, the  Intertek  Mark  as  shown  below,  and  the  Code  Compliance  Research Report number (CCRR‐0258).        9.0 OTHER CODES  9.1 California Building Code    9.1.1  Scope of Evaluation:    The  NichiProducts™  siding  products  were  evaluated  for  compliance with the 2016 and 2013 California Building Code,  including  Chapter  7A.  The  siding  products  are  noncombustible materials as defined in CBC Section 202 and  as permitted for use on exterior walls in CBC Section 707A.3.     Code Compliance Research Report CCRR‐0258  Page 3 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 9.1.2  Conclusion:   The siding products, described in Sections 2.0 through 7.0 of  this  report,  comply  with  the  2016  and  2013  California  Building Code, subject to the conditions noted in Section 6.0  of this report. Section numbers for the CBC – Building and  Residential  correspond  to  the  2015  IBC  and  IRC  section  numbers.    9.2  Florida Building Code    9.2.1  Scope of Evaluation:    The  NichiProducts™ siding products  were  evaluated  for  compliance with the 2017 and 2014 Florida Building Code  –  Building,  Florida  Building  Code  –  Residential and  Florida  Building  Code  –  Energy  Conservation.    9.2.2  Conclusion:    The siding products  described  in  Sections  2.0  through  7.0  of  this  report,  comply  with  the  2017  and  2014  Florida Building  Code – Building, Florida Building Code –  Residential and Florida Building Code – Energy, subject to  the following conditions:   Use of the NichiProducts Siding in Types I, II, III or IV  construction, is as permitted in Florida Building Code –  Building, Section 1406.2.1.   Attachment  of  NichiProducts  for  compliance  with  the  High‐Velocity Hurricane Zone (HVHZ) provisions of the  2017 Florida  Building  Code  –  Building and  the Florida  Building Code – Residential is described in Table 8 of this  report.   In HVHZ applications, the NichiProducts siding must be  installed over CBS construction or 5/8 in. (5‐Ply) plywood  supported by 2 by studs or 2 by 6, No. 18 gage metal studs,  spaced at 16 inches on center.    Section numbers for the FBC – Building and Residential  correspond to the 2015 IBC and IRC section numbers.   Intertek is a Florida State Product Evaluation Entity.    10.0 CODE COMPLIANCE RESEARCH REPORT USE  10.1 Approval  of  building  products  and/or  materials  can  only be granted by a building official having legal authority  in the specific jurisdiction where approval is sought.   10.2 Code Compliance Research Reports shall not be used  in any manner that implies an endorsement of the product  by Intertek.   10.3 Reference to the https://bpdirectory.intertek.com is  recommended to ascertain the current version and status of  this report.  This Code Compliance Research Report (“Report”) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and  its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to  the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit  copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner.  Client further agrees and  understands that reliance upon the Report is limited to the representations made therein.  The Report is not an endorsement or recommendation for use of the  subject and/or product described herein.  This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and  this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or  advertisement of the tested material, product or service must first be approved in writing by Intertek. Code Compliance Research Report CCRR‐0258  Page 4 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 TABLE 1 – PROPERTIES EVALUATED  PROPERTY 2018 and 2015  IBC SECTION1  2018 and 2015  IRC SECTION1  2017 and  2014 FBC ‐  Building  2017 and 2014 FBC –  Residential  2016 and 2013 CBC  Physical properties 1403.10  [1404.10] R703.10  1404.10  R703.10  1404.10  Surface burning characteristics 1403.10  [1404.10] R703.10  1404.10  R703.10  1404.10  Noncombustibility  703.5  NA  703.5  NA  202, 703.5  Wind resistance 1404.16  [1405.16] R703.16  1405.16  703.1.2  1405.16  Weather resistance  1403.2 [1404.2] R703.2  1404.2  R703.2  1404.2   1 Section numbers may be different for earlier versions of the International and Florida Codes.        TABLE 2 – NICHIHA SIDING DESCRIPTION    Product Name Nominal Thickness  (in.) Siding Dimensions  Intended Use  Description  NichiBoard™ plank  5/16  Width: 5.25, 6.25, 7.25, 8.25,  9.25 and 12 inches  Length: 12 feet  Lap siding Smooth or Cedar  finish  NichiPanel™ sheets  5/16  4 feet by 8 feet  4 feet by 10 feet  4 feet by 12 feet  Panel siding  Cedar, Smooth, Stucco  and Grooved‐ 8‐in.‐  oc‐ Cedar finish  NichiStraight™ and  NichiStaggered™ lap panels 5/16  16 inches wide by 4 foot long  Lap panel siding  Designed to look like  individual cedar  shakes  NichiShake™ cladding  5/16  Width: 6.25, 8.25 and 12  inches  Length: 18 inches  Lap shingle siding  Designed to look like  individual cedar  shakes  NichiSoffit™  1/4  12, 16 inches wide by 12 feet  long;  24, 48 inches wide by 8 feet  long  Soffit  Vented or Nonvented;  Smooth or Cedar  finish       Code Compliance Research Report CCRR‐0258  Page 5 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Design Loads for Negative Transverse Wind Load (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing Framing Type  Allowable  Design  Pressure (psf)6 Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2 ASCE 7‐10 or ASCE  7‐16 Ultimate  Wind Speed (MPH)3Frame/  Horizontal  (in)    Field (in)  Exp B Exp C Exp D Exp B Exp C Exp D                         5.25” / 6.25"  NichiBoard™                          6d Double HD MAZE Coil Nail                          Face              16        5.25/6.25      SPF      ‐49.5  15 143 130 118 185 168 153  20 143 126 115 185 163 149 25 143 124 113 185 160 146  30 143 121 111 185 156 144 40 138 118 109 178 152 140 50 133 115 106 172 148 137  60 130 113 105 168 146 135      DF      ‐76.5  15 170 162 147 210 209 190 20 170 157 144 210 203 185 25 170 154 141 210 199 182  30 170 151 139 210 195 179 40 170 146 135 210 189 174 50 166 143 132 210 184 171  60 162 140 130 209 181 168              24              5.25/6.25      SPF      ‐33.0  15 117 106 97 151 137 125 20 117 103 94 151 133 122 25 117 101 93 151 130 119 30 117 99 91 151 128 117 40 112 96 89 145 124 114 50 109 94 87 141 121 112 60 106 92 86 137 119 110      DF      ‐51.0  15 146 132 120 188 171 155  20 146 128 117 188 166 151 25 146 126 115 188 162 149 30 146 123 113 188 159 146 40 140 119 110 180 154 142 50 135 117 108 175 151 140 60 132 115 106 171 148 137  5.25” / 6.25"  NichiBoard™  MAZE 8d nail – 2‐1/2 inches  long, 0.279‐inch dia. head,  0.123‐inch dia. shank  16  5.25/6.25 SPF ‐85  15 170 170 155 210 210 200  20 170 166 151 210 210 195  25 170 162 148 210 209 191  30 170 159 146 210 205 188  40 170 154 142 210 199 184  50 170 150 140 210 194 180  60 170 147 137 210 190 177              5.25” / 6.25"  NichiBoard™              6d Double HD MAZE Coil Nail              Blind      16      5.25/6.25      SPF      ‐35.1  15 121 110 100 156 142 129  20 121 107 97 156 138 126 25 121 104 96 156 135 123 30 121 102 94 156 132 121  40 116 99 92 150 128 118 50 112 97 90 145 125 116 60 110 95 88 142 123 114      24      5.25/6.25      SPF      ‐23.4  15 99 90 ‐‐ 127 116 ‐‐ 20 99 87 ‐‐ 127 112 ‐‐ 25 99 85 ‐‐ 127 110 ‐‐ 30 99 ‐‐ ‐‐ 127 108 ‐‐ 40 95 ‐‐ ‐‐ 122 ‐‐‐‐ 50 92 ‐‐ ‐‐ 118 ‐‐‐‐ 60 90 ‐‐ ‐‐ 116 ‐‐ ‐‐    Code Compliance Research Report CCRR‐0258  Page 6 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing  Framing  Type  Allowable Design  Pressure (psf)6  Building  Height  (ft)  ASCE 7‐05 Basic Wind Speed (MPH)2  ASCE 7‐10 Ultimate Wind Speed (MPH)3 Frame/Horizontal (in)    Field (in)Exp B Exp C Exp D Exp B Exp C Exp D                               5.25” / 6.25"  NichiBoard™                              Double HD MAZE  Asphalt & Fiberglass  Shingle Nail                                  Blind      12      5.25/6.25      7/16"  OSB      ‐41.0  15 130 118 108 168 153 139 20 130 115 105 168 149 136 25 130 113 103 168 145 133 30 130 110 101 168 142 131 40 125 107 99 162 138 128 50 121 105 97 157 135 125 60 118 103 95 153 133 123             16              5.25/6.25      7/16"  OSB      ‐30.7  15 113 103 93 146 132 120 20 113 100 91 146 129 117  25 113 98 89 146 126 115  30 113 96 88 146 123 113  40 108 93 86 140 120 111  50 105 91 ‐‐ 136 117 108  60 103 89 ‐‐ 132 115 107      SPF      ‐56.1  15 153 139 126 197 179 163  20 153 135 123 197 174 159 25 153 132 121 197 170 156 30 153 129 119 197 167 153 40 147 125 116 189 162 149  50 142 122 113 183 158 146  60 139 120 112 179 155 144              24              5.25/6.25      7/16"  OSB      ‐20.5  15 92 ‐‐ ‐‐ 119 108 ‐‐  20 92 ‐‐ ‐‐ 119 105 ‐‐  25 92 ‐‐ ‐‐ 119 ‐‐ ‐‐  30 92 ‐‐ ‐‐119 ‐‐‐‐ 40 89 ‐‐ ‐‐114 ‐‐‐‐ 50 86 ‐‐ ‐‐111 ‐‐‐‐ 60 ‐‐ ‐‐ ‐‐ 108 ‐‐ ‐‐      SPF      ‐37.4  15 125 113 103 161 146 133 20 125 110 100 161 142 130  25 125 108 99 161 139 127  30 125 105 97 161 136 125  40 120 102 94 154 132 122  50 116 100 93 150 129 119  60 113 98 91 146 127 118                    5.25” / 6.25"  NichiBoard™                  Aerosmith  Fastening  Systems,  VersaPin              Face      16      5.256.25      20 GA  Steel      ‐136.3  15 170 170 170 210 210 210  20 170 170 170 210 210 210 25 170 170 170 210 210 210 30 170 170 170 210 210 210 40 170 170 170 210 210 210 50 170 170 170 210 210 210  60 170 170 170 210 210 210      24      5.25/6.25      20 GA  Steel      ‐90.9  15 170 170 160 210 210 207  20 170 170 156 210 210 202  25 170 168 154 210 210 198  30 170 164 151 210 210 195 40 170 159 147 210 206 190 50 170 156 144 210 201 186 60 170 153 142 210 197 183        Blind      16      5.25/6.25      20 GA  Steel      ‐27.5  15 107 97 88 138 125 114  20 107 94 86 138 122 111  25 107 92 ‐‐ 138 119 109  30 107 90 ‐‐ 138 117 107  40 103 88 ‐‐ 132 113 ‐‐  50 99 86 ‐‐ 128 111 ‐‐  60 97 ‐‐ ‐‐ 125 109 ‐‐       Code Compliance Research Report CCRR‐0258  Page 7 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing   Framing  Type  Allowable  Design  Pressure (psf)6  Building  Height (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE 7‐10 Ultimate Wind Speed (MPH)3 Frame/Horizontal (in)    Field (in)Exp B Exp C Exp D Exp B Exp C Exp D                               7.25" NichiBoard™                                6d Double HD  MAZE Coil Nail                            Face              16              7.25      SPF      ‐42.7  15 133 121 110 172 156 142 20 133 117 107 172 152 138 25 133 115 105 172 148 136 30 133 113 103 172 145 134 40 128 109 101 165 141 130 50 124 107 99 160 138 128 60 121 105 97 156 135 126     DF   ‐66.0  15 166 150 136 210 194 176 20 166 146 133 210 188 172 25 166 143 131 210 184 169 30 166 140 129 210 181 166 40 159 136 125 205 175 162 50 154 133 123 199 171 159 60 150 130 121 194 168 156             24              7.25      SPF   ‐28.4  15 109 99 90 140 127 116 20 109 96 88 140 124 113 25 109 94 86 140 121 111 30 109 92 ‐‐ 140 119 109 40 104 89 ‐‐ 135 115 106 50 101 87 ‐‐ 130 112 ‐‐ 60 99 86 ‐‐ 127 110 ‐‐     DF ‐44.0  15 135 123 111 175 158 144 20 135 119 109 175 154 140 25 135 117 107 175 151 138 30 135 114 105 175 147 136 40 130 111 102 167 143 132 50 126 108 100 162 140 130 60 123 106 99 158 137 128 Blind        16        7.25      SPF ‐26.1  15 104 95 86 135 122 111 20 104 92 ‐‐ 135 119 108 25 104 90 ‐‐ 135 116 106 30 104 88 ‐‐ 135 114 ‐‐ 40 100 85 ‐‐ 129 110 ‐‐ 50 97 ‐‐ ‐‐ 125 108 ‐‐ 60 95 ‐‐ ‐‐ 122 106 ‐‐ MAZE 8d nail – 2‐1/2  inches long, 0.279‐ inch dia. head, 0.123‐ inch dia. shank  Face  16  7.25  SPF ‐85  15 170 170 155 210 210 200 20 170 166 151 210 210 195 25 170 162 148 210 209 191 30 170 159 146 210 205 188 40 170 154 142 210 199 184 50 170 150 140 210 194 180 60 170 147 137 210 190 177                     Code Compliance Research Report CCRR‐0258  Page 8 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing   Framing  Type  Allowable  Design  Pressure (psf)6  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE 7‐10 Ultimate Wind Speed (MPH)3 Frame/Horizontal (in)    Field (in)Exp B Exp C Exp D Exp B Exp C Exp D                   7.25" NichiBoard™                  Double HD MAZE  Asphalt & Fiberglass  Shingle Nail                    Blind        12        7.25      7/16"  OSB        ‐35.3  15 121 110 100 156 142 129 20 121 107 98 156 138 126 25 121 105 96 156 135 124 30 121 102 94 156 132 122 40 116 99 92 150 128 118 50 113 97 90 145 125 116 60 110 95 89 142 123 114       24        7.25        SPF        ‐25.2  15 102 93 ‐‐ 132 120 109 20 102 90 ‐‐ 132 117 106 25 102 88 ‐‐ 132 114 ‐‐ 30 102 87 ‐‐ 132 112 ‐‐ 40 98 ‐‐ ‐‐ 127 108 ‐‐ 50 95 ‐‐ ‐‐ 123 106 ‐‐ 60 93 ‐‐ ‐‐ 120 ‐‐‐‐ 7.25” NichiBoard  MAZE R‐104 (1‐3/4  in. long, 0.144 in.  shank, 0.326 in.  head)  Blind  16  7.25  SPF ‐53  15 148 135 122 192 174 158  20 148 131 119 192 169 154  25 148 128 117 192 165 151  30 148 125 115 192 162 149  40 142 122 112 184 157 145  50 138 119 110 178 153 142  60 134 116 108 173 150 140       Code Compliance Research Report CCRR‐0258  Page 9 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing  Framing Type  Allowa ble  Desi Building  Height (ft) ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE 7‐10 Ultimate Wind Speed (MPH)3 Frame/Horizontal (in)   Field (in) Exp B Exp C Exp D Exp B Exp C Exp D             7.25"  NichiBoard™            Aerosmith  Fastening  Systems,  VersaPin              Face        16        7.25      20 GA  Steel        ‐117.5  15 170 170 170 210 210 210 20 170 170 170 210 210 210 25 170 170 170 210 210 210 30 170 170 170 210 210 210 40 170 170 167 210 210 210 50 170 170 164 210 210 210 60 170 170 162 210 210 209       24        7.25      20 GA  Steel        ‐78.3  15 170 164 149 210 210 192 20 170 159 145 210 205 188 25 170 156 143 210 201 184 30 170 152 140 210 197 181 40 170 148 137 210 191 176 50 168 145 134 210 187 173 60 164 142 132 210 183 170                         8.25"  NichiBoard™                            6d Double HD  MAZE Coil Nail                          Face              16              8.25        SPF        ‐37.5  15 125 113 103 161 146 133 20 125 110 100 161 142 130 25 125 108 99 161 139 127 30 125 105 97 161 136 125 40 120 102 95 155 132 122 50 116 100 93 150 129 120 60 113 98 91 146 127 118       DF        ‐58.0  15 155 141 128 200 182 165 20 155 137 125 200 177 161 25 155 134 123 200 173 158 30 155 131 121 200 169 156 40 149 127 118 192 164 152 50 144 124 115 186 161 149 60 141 122 113 182 158 146             24              8.25        SPF        ‐25.0  15 102 92 ‐‐132 119 108 20 102 90 ‐‐132 116 106 25 102 88 ‐‐132 114 ‐‐ 30 102 86 ‐‐132 111 ‐‐    40 98 ‐‐ ‐‐126 108 ‐‐ 50 95 ‐‐ ‐‐122 105 ‐‐ 60 92 ‐‐ ‐‐119 ‐‐‐‐       DF        ‐38.6  15 127 115 104 164 148 135 20 127 112 102 164 144 132 25 127 109 100 164 141 129 30 127 107 98 164 138 127 40 122 104 96 157 134 124 50 118 102 94 152 131 121 60 115 100 93 148 129 120 MAZE 8d nail – 2‐ 1/2 inches long,  0.279‐inch dia.  head, 0.123‐inch  dia. shank  Face  16  8.25  SPF ‐85  15 170 170 155 210 210 200  20 170 166 151 210 210 195  25 170 162 148 210 209 191  30 170 159 146 210 205 188  40 170 154 142 210 199 184  50 170 150 140 210 194 180  60 170 147 137 210 190 177            Code Compliance Research Report CCRR‐0258  Page 10 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing Framing Type  Allowa ble  Desi gn  Pressure6 Building  Height (ft) ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE 7‐10 Ultimate  Wind Speed (MPH)3 Frame/Horizontal (in)    Field (in)  Exp B Exp C Exp D Exp B Exp C Exp D             8.25"  NichiBoard™            Double HD MAZE  Asphalt &  Fiberglass Shingle  Nail              Blind        12        8.25      7/16"  OSB        ‐29.5  15 111 100 91 143 130 118 20 111 98 89 143 126 115 25 111 96 87 143 123 113 30 111 94 86 143 121 111 40 106 91 ‐‐137 117 108 50 103 89 ‐‐133 114 106 60 100 87 ‐‐ 130 112 ‐‐  MAZE R‐104, 1‐ 3/4” long, 0.326  in. dia. head,  0.144 in. dia.  shank        16        8.25        SPF        ‐46  15 138 126 114 178 162 147    20 138 122 111 178 157 143 25 138 119 109 178 154 141 30 138 117 107 178 151 139 40 133 113 105 171 146 135 50 128 111 103 166 143 132 60 125 108 101 162 140 130           Aerosmith  Fastening  Systems, VersaPin              Face        16        8.25      20 GA  Steel        ‐103.3  15 170 170 170 210 210 210 20 170 170 167 210 210 210 25 170 170 164 210 210 210 30 170 170 161 210 210 208 40 170 170 157 210 210 203 50 170 166 154 210 210 199 60 170 163 151 210 210 195       24        8.25      20 GA  Steel        ‐68.8  15 169 153 139 210 198 180 20 169 149 136 210 193 176 25 169 146 134 210 188 173 30 169 143 131 210 185 170 40 162 139 128 210 179 165 50 157 136 126 203 175 162 60 153 133 124 198 172 160     Code Compliance Research Report CCRR‐0258  Page 11 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing  Framing  Type  Allowable Design  Pressure (psf)6  Building  Height  (ft)  ASCE 7‐05 Basic Wind Speed (MPH)2  ASCE 7‐10 Ultimate Wind Speed (MPH)3 Frame/Horizontal (in)    Field (in) Exp B Exp C Exp D Exp B Exp C Exp D                         9.25"  NichiBoard™                          6d Double HD  MAZE Coil Nail                            Face              16              9.25        SPF        ‐33.4  15 118 107 97 152 138 125  20 118 104 95 152 134 122  25 118 102 93 152 131 120  30 118 100 92 152 129 118  40 113 97 89 146 125 115 50 110 94 88 141 122 113  60 107 93 86 138 120 111        DF        ‐51.7  15 147 133 121 189 172 156  20 147 129 118 189 167 152  25 147 126 116 189 163 150 30 147 124 114 189 160 147 40 141 120 111 182 155 143  50 136 117 109 176 152 140 60 133 115 107 172 149 138  24   9.25    SPF        ‐22.3  15 96 87 ‐‐ 124 113 ‐‐  20 96 ‐‐ ‐‐ 124 110 ‐‐  25 96 ‐‐ ‐‐ 124 107 ‐‐  30 96 ‐‐ ‐‐124 ‐‐‐‐ 40 92 ‐‐ ‐‐119 ‐‐‐‐ 50 89 ‐‐ ‐‐ 115 ‐‐ ‐‐  60 87 ‐‐ ‐‐ 113 ‐‐ ‐‐        DF        ‐34.5  15 120 109 99 154 140 127 20 120 106 96 154 136 124  25 120 103 95 154 133 122  30 120 101 93 154 131 120  40 115 98 91 148 127 117 50 111 96 89 144 124 115  60 109 94 87 140 122 113  MAZE 8d nail – 2‐1/2  inches long, 0.279‐ inch dia. head, 0.123‐ inch dia. shank  16  9.25  SPF ‐85  15 170 170 155 210 210 200  20 170 166 151 210 210 195  25 170 162 148 210 209 191  30 170 159 146 210 205 188  40 170 154 142 210 199 184  50 170 150 140 210 194 180  60 170 147 137 210 190 177      9.25"  NichiBoard™    Double HD MAZE  Asphalt & Fiberglass  Shingle Nail       Blind        12        9.25      7/16" OSB        ‐23.5  15 99 90 ‐‐ 127 116 105  20 99 87 ‐‐127 112 ‐‐ 25 99 85 ‐‐ 127 110 ‐‐  30 99 ‐‐ ‐‐ 127 108 ‐‐  40 95 ‐‐ ‐‐ 122 ‐‐ ‐‐  50 92 ‐‐ ‐‐118 ‐‐‐‐ 60 90 ‐‐ ‐‐ 116 ‐‐ ‐‐  MAZE R‐104 nail: 1‐ 3/4” long, 0.326 in.  dia. head, 0.144 in.  dia. shank  16  9.25  SPF ‐34  15 119 108 98 153 139 126  20 119 105 96 153 135 123  25 119 102 94 153 132 121  30 119 100 92 153 130 119  40 114 97 90 147 126 116  50 110 95 88 143 123 114  60 108 93 87 139 120 112            Code Compliance Research Report CCRR‐0258  Page 12 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing  Framing  Type  Allowable  Design  Pressure (psf)6  Building  Height  (ft)  ASCE 7‐05 Basic Wind Speed (MPH)2  ASCE 7‐10 Ultimate Wind Speed (MPH)3 Frame/Horizontal (in)    Field (in) Exp B Exp C Exp D Exp B Exp C Exp D             9.25"  NichiBoard™            Aerosmith  Fastening  Systems,  VersaPin              Face        16        9.25      20 GA  Steel        ‐92.1  15 170 170 161 210 210 208  20 170 170 157 210 210 203  25 170 169 155 210 210 200 30 170 165 152 210 210 196  40 170 160 148 210 207 191  50 170 157 145 210 202 188  60 170 154 143 210 199 185        24        9.25      20 GA  Steel        ‐61.4  15 160 145 132 206 187 170  20 160 141 129 206 182 166  25 160 138 126 206 178 163  30 160 135 124 206 174 160 40 153 131 121 198 169 156  50 148 128 119 192 165 153  60 145 126 117 187 162 151    Code Compliance Research Report CCRR‐0258  Page 13 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 3 ‐ Continued (NichiBoard™ Plank)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing Framing  Type  Allowable Design  Pressure (psf)6  Building Height  (ft)  ASCE 7‐05 Basic Wind Speed (MPH)2  ASCE 7‐10 Ultimate Wind Speed (MPH)3 Frame/Horizontal (in) Field (in)Exp B Exp C Exp D Exp B Exp C Exp D                         12" NichiBoard™                          6d Double HD  MAZE Coil Nail                          Face              16              12        SPF        ‐25.8  15 103 94 85 134 121 110 20 103 91 ‐‐ 134 118 108 25 103 89 ‐‐134 115 106 30 103 87 ‐‐134 113 ‐‐ 40 99 ‐‐ ‐‐ 128 110 ‐‐  50 96 ‐‐ ‐‐ 124 107 ‐‐  60 94 ‐‐ ‐‐ 121 105 ‐‐        DF        ‐39.8  15 129 117 106 166 151 137 20 129 113 104 166 147 134 25 129 111 102 166 143 131 30 129 109 100 166 140 129 40 123 106 97 159 136 126 50 120 103 96 154 133 123 60 117 101 94 151 131 121             24              12        SPF        ‐17.2  15 ‐‐ ‐‐ ‐‐109 ‐‐‐‐ 20 ‐‐ ‐‐ ‐‐ 109 ‐‐ ‐‐  25 ‐‐ ‐‐ ‐‐ 109 ‐‐ ‐‐  30 ‐‐ ‐‐ ‐‐ 109 ‐‐ ‐‐  40 ‐‐ ‐‐ ‐‐ ‐‐ ‐‐ ‐‐  50 ‐‐ ‐‐ ‐‐ ‐‐ ‐‐ ‐‐  60 ‐‐ ‐‐ ‐‐ ‐‐ ‐‐ ‐‐        DF        ‐26.6  15 105 95 87 136 123 112 20 105 93 ‐‐136 120 109 25 105 91 ‐‐136 117 107 30 105 89 ‐‐ 136 115 105 40 101 86 ‐‐ 130 111 ‐‐  50 98 ‐‐ ‐‐126 109 ‐‐ 60 95 ‐‐ ‐‐ 123 107 ‐‐              12" NichiBoard™            Aerosmith  Fastening  Systems,  VersaPin              Face        16        12      20 GA  Steel        ‐71.0  15 170 156 142 210 201 183 20 170 151 138 210 196 179 25 170 148 136 210 191 175 30 170 145 133 210 187 172 40 165 141 130 210 182 168 50 160 138 128 206 178 165 60 156 135 126 201 175 162        24        12      20 GA  Steel        ‐47.3  15 140 127 116 181 164 149 20 140 124 113 181 160 146 25 140 121 111 181 156 143  30 140 119 109 181 153 141  40 135 115 106 174 149 137 50 130 112 104 168 145 134  60 127 110 103 164 142 132  Notes:  1. NichiBoard™ fiber cement lap  siding may only be installed on vertical walls. Fasteners  must be installed  in a way that does not damage the board during installation.   Where  necessary,  pre‐drilled  holes may be used in combination with hand‐nailed  fasteners  to avoid damage  to the fiber cement product.  2. ASCE 7‐05 Basic Wind Speeds are based upon occupancy  category II, a wind directionality factor (Kd) equal to 0.85, an internal pressure  coefficient  (GCpi) equal to +/‐0.18,  and an external pressure  coefficient  (GCp) equal to ‐1.4. The effects of topographic  features have not been considered  and the wind speed has been limited to 170mph.  3. ASCE 7‐10 and SCE 7‐16 Ultimate  Wind Speeds are based upon a wind directionality factor (Kd) equal to 0.85, an internal pressure  coefficient  (GCpi) equal to +/‐0.18, and  an external pressure coefficient  (GCp) equal to ‐1.4. Under ASCE 7‐16, the wind speeds are based on Ke = 1.0. The effects of topographic features  have not been considered  and the wind speed has been limited to 210mph.  4. The values in this table are based on testing per ASTM E330 and represent  the allowable  capacity of the siding to resist the wind pressures  associated  with the  corresponding wind  speed.  5. Fastener  specifications for those used in testing are outlined in Table 9 of this Intertek CCRR. These specifications may be used by the designer  of record to determine  the acceptability of alternative fasteners.  6. Allowable  design pressures  in highlighted  cells have been adjusted  based on the listed allowable  withdrawal  capacity of the tested fastener.  7. Framing  and bracing are beyond  the scope of this evaluation report.  8. Allowable design pressures for assemblies described in this table may be applied where the NichiBoard Plank is attached to ASTM C90 fully‐grouted CMU block wall using ITW Ramset TE  Series power actuated fasteners (ICC‐ES ESR‐1799). Minimum fastener embedment is 1 inch; fasteners must be placed a minimum of 5.1 inches from the edge of the wall.  Code Compliance Research Report CCRR‐0258  Page 14 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 4 ‐ Design Loads for Negative Transverse Wind Load (NichiPanel™ Sheet)1,4,7      Panel Fastener5  Fastener Spacing  Framing  Type  Framing  Spacing  Allowable Design  6 Pressure (psf)  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE7‐10Ultimate Wind Speed(MPH) 3 Perimeter  (in)    Field (in) Exp B Exp C Exp D Exp B Exp C Exp D     6d Double HD MAZE Coil  Nail        6        12      SPF Lumber       16''o.c.        ‐28.7  15 109 99 90 141 128 116  20 109 96 88 141 124 113  25 109 94 86 141 122 111  30 109 92 ‐‐ 141 119 109  40 105 90 ‐‐ 135 116 107  50 101 87 ‐‐ 131 113 ‐‐  60 99 86 ‐‐ 128 111 ‐‐              6d Double HD MAZE Coil  Nail                8                8              SPF Lumber       16''o.c.        ‐43.0  15 134 121 110 173 157 142  20 134 118 108 173 152 139  25 134 115 106 173 149 136  30 134 113 104 173 146 134  40 128 110 101 166 142 131  50 124 107 99 160 138 128  60 121 105 98 157 136 126        24''o.c.        ‐30.4  15 112 102 93 145 132 120  20 112 99 91 145 128 117  25 112 97 89 145 125 115  30 112 95 87 145 123 113  40 108 92 85 139 119 110  50 105 90 ‐‐ 135 116 108  60 102 88 ‐‐ 132 114 106      MAZE CEM‐6 nail: 2 in.  long, 0.278 in. head, .119  in. shank                  6                6              SPF Lumber       16''o.c.        ‐75  15 170 160 146 210 207 188  20 170 156 142 210 201 183  25 170 152 139 210 196 180  30 170 149 137 210 192 177  40 169 145 134 210 187 173  50 164 141 131 210 182 169  60 160 139 129 206 179 167          24''o.c.        ‐40.6  15 130 118 107 168 152 138  20 130 115 105 168 148 135  25 130 112 103 168 145 133  30 130 110 101 168 142 130  40 125 107 98 161 138 127  50 121 104 96 156 134 125  60 118 102 95 152 132 123              6d Double HD MAZE Coil  Nail                4                4              SPF Lumber       16''o.c.        ‐85.9  15 170 170 156 210 210 201  20 170 167 152 210 210 196  25 170 163 149 210 210 193  30 170 160 147 210 206 189  40 170 155 143 210 200 185  50 170 151 140 210 195 181  60 170 149 138 210 192 178        24''o.c.        ‐60.9  15 159 144 131 205 186 169  20 159 140 128 205 181 165  25 159 137 126 205 177 162  30 159 134 124 205 174 159  40 153 130 120 197 168 156  50 148 127 118 191 165 152  60 144 125 116 186 162 150    Code Compliance Research Report CCRR‐0258  Page 15 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 4 ‐ Continued (NichiPanel™ Sheet)1,4,7      Panel Fastener5  Fastener Spacing  Framing  Type  Framing  Spacing  Allowable Design  6 Pressure (psf)  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE7‐10Ultimate Wind Speed(MPH) 3 Perimeter  (in)    Field (in) Exp B Exp C Exp D Exp B Exp C Exp D             8d Masonite Siding  Nails                6                12              SPF  Lumber        16''o.c.        ‐39.9  15 129 117 106 166 151 137  20 129 114 104 166 147 134  25 129 111 102 166 143 131  30 129 109 100 166 141 129  40 124 106 98 160 136 126  50 120 103 96 155 133 123  60 117 101 94 151 131 122        24''o.c.        ‐26.6  15 105 95 87 136 123 112  20 105 93 ‐‐ 136 120 109  25 105 91 ‐‐ 136 117 107  30 105 89 ‐‐ 136 115 105  40 101 86 ‐‐ 130 111 ‐‐  50 98 ‐‐ ‐‐ 126 109 ‐‐  60 95 ‐‐ ‐‐ 123 107 ‐‐              8d Masonite Siding  Nails                8                8              SPF  Lumber        16''o.c.        ‐59.9  15 158 143 130 204 185 168  20 158 139 127 204 180 164  25 158 136 125 204 176 161  30 158 133 123 204 172 158  40 151 129 119 195 167 154  50 147 126 117 189 163 151  60 143 124 115 185 160 149        24''o.c.        ‐39.9  15 129 117 106 166 151 137  20 129 114 104 166 147 134  25 129 111 102 166 143 131  30 129 109 100 166 141 129  40 124 106 98 160 136 126  50 120 103 96 155 133 123  60 117 101 94 151 131 122              8d Masonite Siding  Nails                6                6              SPF Lumber       16''o.c.        ‐79.9  15 170 165 150 210 210 194  20 170 161 147 210 207 189  25 170 157 144 210 203 186  30 170 154 142 210 199 183  40 170 149 138 210 193 178  50 169 146 135 210 188 175  60 165 143 133 210 185 172        24''o.c.        ‐53.3  15 149 135 123 192 174 158  20 149 131 120 192 169 155  25 149 128 118 192 166 152  30 149 126 116 192 162 149  40 143 122 113 184 158 145  50 138 119 110 179 154 143  60 135 117 109 174 151 140     Code Compliance Research Report CCRR‐0258  Page 16 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 4 ‐ Continued (NichiPanel™ Sheet)1,4,7      Panel Fastener5  Fastener Spacing  Framing  Type  Framing  Spacing  Allowable Design  6 Pressure (psf)  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE7‐10Ultimate Wind Speed(MPH) 3 Perimeter  (in)    Field (in) Exp B Exp C Exp D Exp B Exp C Exp D             8d Masonite Siding  Nails                4                4              SPF  Lumber        16''o.c.        ‐119.8  15 170 170 170 210 210 210  20 170 170 170 210 210 210  25 170 170 170 210 210 210  30 170 170 170 210 210 210  40 170 170 169 210 210 210  50 170 170 166 210 210 210  60 170 170 163 210 210 210        24''o.c.        ‐79.9  15 170 165 150 210 210 194  20 170 161 147 210 207 189  25 170 157 144 210 203 186  30 170 154 142 210 199 183  40 170 149 138 210 193 178  50 169 146 135 210 188 175  60 165 143 133 210 185 172       Code Compliance Research Report CCRR‐0258  Page 17 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 4 ‐ Continued (NichiPanel™ Sheet)1,4,7      Panel Fastener5  FastenerSpacing  Framing  Type  Framing  Spacing  Allowable Design  6 Pressure (psf)  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE 7‐10 Ultimate  Wind Speed (MPH)3 Perimeter  (in)    Field (in) Exp B Exp C Exp D Exp B Exp C Exp D                           Grabber #8 Flat  Wafer Head Screws                              6                              12              SPF  Lumber        16''o.c.        ‐55.9  15 152 138 126 197 179 162 20 152 134 123 197 173 158 25 152 131 120 197 170 156  30 152 129 118 197 166 153  40 146 125 115 189 161 149  50 142 122 113 183 158 146  60 138 120 111 179 155 144        24''o.c.        ‐37.3  15 124 113 103 161 146 132 20 124 110 100 161 142 129  25 124 107 98 161 139 127  30 124 105 97 161 136 125  40 119 102 94 154 132 122  50 116 100 92 149 129 119 60 113 98 91 146 126 117              20 GA  Steel        16''o.c.        ‐48.5  15 142 129 117 183 166 151 20 142 125 114 183 162 148  25 142 123 112 183 158 145  30 142 120 110 183 155 142  40 136 116 108 176 150 139 50 132 114 105 170 147 136 60 129 112 104 166 144 134        24''o.c.        ‐32.4  15 116 105 96 150 136 123 20 116 102 93 150 132 121  25 116 100 92 150 129 118  30 116 98 90 150 127 116 40 111 95 88 144 123 113 50 108 93 86 139 120 111 60 105 91 ‐‐ 136 118 109                            Grabber #8 Flat  Wafer Head Screws                              8                              8              SPF  Lumber        16''o.c.        ‐83.8  15 170 169 154 210 210 199 20 170 165 150 210 210 194  25 170 161 147 210 208 190 30 170 158 145 210 204 187 40 170 153 141 210 198 182 50 170 149 138 210 193 179 60 169 147 136 210 190 176        24''o.c.        ‐55.9  15 152 138 126 197 179 162 20 152 134 123 197 173 158 25 152 131 120 197 170 156 30 152 129 118 197 166 153 40 146 125 115 189 161 149 50 142 122 113 183 158 146 60 138 120 111 179 155 144              20 GA  Steel        16''o.c.        ‐72.8  15 170 158 143 210 204 185 20 170 153 140 210 198 181 25 170 150 137 210 194 177 30 170 147 135 210 190 174 40 167 143 132 210 184 170 50 162 139 129 209 180 167 60 158 137 127 204 177 164       24''o.c.        ‐48.5  15 142 129 117 183 166 151 20 142 125 114 183 162 148 25 142 123 112 183 158 145 30 142 120 110 183 155 142 40 136 116 108 176 150 139 50 132 114 105 170 147 136 60 129 112 104 166 144 134 Code Compliance Research Report CCRR‐0258  Page 18 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 4 ‐ Continued (NichiPanel™ Sheet)1,4,7        Panel Fastener5  FastenerSpacing  Framing  Type  Framing  Spacing  Allowable Design  6 Pressure (psf)  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE 7‐10 Ultimate  Wind Speed (MPH)3 Perimeter  (in)    Field (in) Exp B Exp C Exp D Exp B Exp C Exp D                           Grabber #8 Flat  Wafer Head Screws                              6                              6              SPF  Lumber        16''o.c.        ‐111.8  15 170 170 170 210 210 210 20 170 170 170 210 210 210 25 170 170 170 210 210 210  30 170 170 167 210 210 210  40 170 170 163 210 210 210  50 170 170 160 210 210 207  60 170 170 158 210 210 203        24''o.c.        ‐74.5  15 170 160 145 210 206 187 20 170 155 142 210 200 183  25 170 152 139 210 196 180  30 170 149 137 210 192 176  40 169 144 133 210 186 172  50 164 141 131 210 182 169 60 160 138 129 206 179 166              20 GA  Steel        16''o.c.        ‐97.0  15 170 170 166 210 210 210 20 170 170 162 210 210 209  25 170 170 159 210 210 205  30 170 170 156 210 210 201  40 170 165 152 210 210 196 50 170 161 149 210 208 192 60 170 158 147 210 204 189        24''o.c.        ‐64.6  15 164 149 135 210 192 174 20 164 145 132 210 187 170  25 164 141 130 210 183 167  30 164 138 127 210 179 164 40 157 134 124 203 174 160 50 152 131 122 197 170 157 60 149 129 12 192 167 155                            Grabber #8 Flat  Wafer Head Screws                              4                              4              SPF  Lumber        16''o.c.        ‐136.0  15 170 170 170 210 210 210 20 170 170 170 210 210 210  25 170 170 170 210 210 210 30 170 170 170 210 210 210 40 170 170 170 210 210 210 50 170 170 170 210 210 210 60 170 170 170 210 210 210        24''o.c.        ‐90.6  15 170 170 160 210 210 207 20 170 170 156 210 210 202 25 170 167 153 210 210 198 30 170 164 151 210 210 195 40 170 159 147 210 206 190 50 170 156 144 210 201 186 60 170 153 142 210 197 183              20 GA  Steel        16''o.c.        ‐136.0  15 170 170 170 210 210 210 20 170 170 170 210 210 210 25 170 170 170 210 210 210 30 170 170 170 210 210 210 40 170 170 170 210 210 210 50 170 170 170 210 210 210 60 170 170 170 210 210 210       24''o.c.        ‐90.6  15 170 170 160 210 210 207 20 170 170 156 210 210 202 25 170 167 153 210 210 198 30 170 164 151 210 210 195 40 170 159 147 210 206 190 50 170 156 144 210 201 186 60 170 153 142 210 197 183 Code Compliance Research Report CCRR‐0258  Page 19 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 4 ‐ Continued (NichiPanel™ Sheet)1,4,7      Panel Fastener5  Fastener Spacing  Framing  Type  Framing  Spacing  Allowable Design  Pressure (psf)6  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE7‐10Ultimate Wind Speed(MPH) 3 Perimeter  (in) Field (in) Exp B Exp C Exp D ExpB ExpC ExpD     Aerosmith Fastening  Systems, VersaPin        6        12      20 GA  Steel        16''o.c.        ‐29.3  15 110 100 91 142 129 117  20 110 97 89 142 126 115  25 110 95 87 142 123 113  30 110 93 86 142 120 111  40 106 90 ‐‐ 137 117 108  50 102 88 ‐‐ 132 114 106  60 100 87 ‐‐ 129 112 ‐‐      Aerosmith Fastening  Systems, VersaPin        8        8      20 GA  Steel        16''o.c.        ‐43.9  15 135 123 111 174 158 144  20 135 119 109 174 154 140  25 135 117 107 174 150 138  30 135 114 105 174 147 135  40 130 111 102 167 143 132  50 126 108 100 162 140 129  60 123 106 99 158 137 127      Aerosmith Fastening  Systems, VersaPin        6        6      20 GA  Steel        16''o.c.        ‐58.5  15 156 141 129 201 183 166  20 156 137 126 201 178 162  25 156 135 123 201 174 159  30 156 132 121 201 170 156  40 150 128 118 193 165 152  50 145 125 116 187 161 149  60 141 123 114 183 158 147              Aerosmith Fastening  Systems, VersaPin                4                4              20 GA  Steel        16''o.c.        ‐87.9  15 170 170 158 210 210 203  20 170 169 154 210 210 199  25 170 165 151 210 210 195  30 170 161 148 210 208 192  40 170 157 145 210 202 187  50 170 153 142 210 198 183  60 170 150 140 210 194 180        24''o.c.        ‐35.6  15 122 110 100 157 143 129  20 122 107 98 157 139 126  25 122 105 96 157 136 124  30 122 103 95 157 133 122  40 117 100 92 151 129 119  50 113 98 90 146 126 117  60 110 96 89 143 124 115  Notes:  1. NichiPanel™ fiber cement flat sheet siding may only be installed on vertical walls. Fasteners must be installed in a way that does not damage the  board during installation.  Where necessary, pre‐drilled holes may be used in combination with hand‐nailed fasteners to avoid damage to the fiber  cement product.  2. ASCE 7‐05 Basic Wind Speeds are based upon occupancy category II, a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (Gcpi) equal to +/‐  0.18, and an external pressure coefficient (GCp) equal to ‐1.4. The effects of topographic features have not been considered and the wind speed has been limited to  170mph.  3. ASCE 7‐10 and ASCE 7‐16 Ultimate Wind Speeds are based upon a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (Gcpi) equal to +/‐0.18,  and an external pressure coefficient (GCp) equal to ‐1.4. Under ASCE 7‐16, the wind speeds are based on Ke = 1.0. The effects of topographic features have not been  considered and the wind speed has been limited to 210mph.  4. The values in this table are based on testing per ASTM E330 and represent the allowable capacity of the siding to resist the wind pressures associated  with the corresponding wind speed.  5. Fastener specifications for those used in testing are outlined in Table 9 of this Intertek CCRR.  These specifications may be used by the designer of record  to determine the acceptability of alternative fasteners.  6. Allowable design pressures in highlighted cells have been adjusted based on the listed allowable withdrawal capacity of the tested fastener.  7. Framing and bracing are beyond the scope of this evaluation report.  8. Allowable design pressures for assemblies described in this table may be applied where the NichiPanel is attached to ASTM C90 fully‐grouted CMU block wall using ITW  Ramset TE Series power actuated fasteners (ICC‐ES ESR‐1799). Minimum fastener embedment is 1 inch; fasteners must be placed a minimum of 5.1 inches from the edge of  the wall.  Code Compliance Research Report CCRR‐0258  Page 20 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 5 ‐ Design Loads for Negative Transverse Wind Load (NichiStraight™/NichiStaggered™ Lap Panel)1,4,7      Siding Type    Siding Fastener5    Face/Blind  Effective Fastener Spacing  Framing  Type  Allowable Design  Pressure (psf)6  Building  Height  (ft)  ASCE 7‐05 Basic Wind Speed (MPH)2  ASCE7‐10Ultimate Wind Speed (MPH)3 Frame/Horizontal  (in) Field (in) Exp B Exp C Exp D Exp B Exp C Exp D                   NichiStraight™/  NichiStaggered™                      6d Double HD MAZE  Coil Nail      Blind        12        8.625      7/16"  OSB        ‐23.5  15 99 90 ‐‐ 128 116 105  20 99 87 ‐‐ 128 113 ‐‐  25 99 85 ‐‐ 128 110 ‐‐  30 99 ‐‐ ‐‐ 128 108 ‐‐  40 95 ‐‐ ‐‐ 122 ‐‐ ‐‐  50 92 ‐‐ ‐‐ 119 ‐‐ ‐‐  60 90 ‐‐ ‐‐ 116 ‐‐ ‐‐        16        8.625        SPF        ‐35.9  15 122 111 101 158 143 130  20 122 108 98 158 139 127  25 122 105 96 158 136 125  30 122 103 95 158 133 122  40 117 100 92 151 129 119  50 113 98 91 146 126 117  60 111 96 89 143 124 115        24        8.625        SPF        ‐23.9  15 100 90 ‐‐ 129 117 106  20 100 88 ‐‐ 129 113 ‐‐  25 100 86 ‐‐ 129 111 ‐‐  30 100 ‐‐ ‐‐ 129 109 ‐‐  40 96 ‐‐ ‐‐ 123 106 ‐‐  50 93 ‐‐ ‐‐ 120 ‐‐ ‐‐  60 90 ‐‐ ‐‐ 117 ‐‐ ‐‐  MAZE 8d nail:  2‐1/2  in. long, 0.279 in. dia.  head, 0.123 in. dia.  shank  Blind  16 8.625 SPF ‐70  15 170 155 141 210 200 181  20 170 150 137 210 194 177  25 170 147 134 210 189 174  30 170 144 132 210 186 171  40 164 140 129 210 180 167  50 158 136 127 205 176 163  60 154 134 125 199 173 161      NichiStraight™/  NichiStaggered™      #8‐18 Wafer Head  ROCK‐ON™ Screws    Blind        24        8.625      20 GA  Steel        ‐49.6  15 144 130 118 185 168 153  20 144 127 116 185 163 149  25 144 124 114 185 160 147  30 144 121 112 185 157 144  40 138 118 109 178 152 140  50 133 115 107 172 149 138  60 130 113 105 168 146 136  Notes:  1. NichiStraight™/NichiStaggered™ Lap Panel fiber cement siding may only be installed on vertical walls. Fasteners must be installed in a way that  does not damage the board during installation. Where necessary, pre‐drilled holes may be used in combination with hand‐nailed fasteners to avoid  damage to the fiber cement product.  2. ASCE 7‐05 Basic Wind Speeds are based upon occupancy category II, a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (Gcpi) equal to +/‐ 0.18, and an external pressure coefficient (GCp) equal to ‐1.4. Under ASCE 7‐16, the wind speeds are based on Ke = 1.0. The effects of topographic features have not been  considered and the wind speed has been limited to 170mph.  3. ASCE 7‐10 and ASCE 7‐16 Ultimate Wind Speeds are based upon a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (Gcpi) equal to +/‐0.18,  and an external pressure coefficient (GCp) equal to ‐1.4. Under ASCE 7‐16, the wind speeds are based on Ke = 1.0.  The effects of topographic features have not been  considered and the wind speed has been limited to 210mph.  4. The values in this table are based on testing per ASTM E330 and represent the allowable capacity of the siding to resist the wind pressures associated  with the corresponding wind speed.  5. Fastener specifications for those used in testing are outlined in Table 9 of this Intertek CCRR. These specifications may be used by the designer of record to  determine the acceptability of alternative fasteners.  6. Allowable design pressures in highlighted cells have been adjusted based on the listed allowable withdrawal capacity of the tested fastener.  7. Framing and bracing are beyond the scope of this evaluation report.  8. Allowable design pressures for assemblies described in this table may be applied where the NichiStraight/NichiStaggered lap panels are attached to ASTM C90 fully‐ grouted CMU block wall using ITW Ramset TE Series power actuated fasteners (ICC‐ES ESR‐1799). Minimum fastener embedment is 1 inch; fasteners must be placed a  minimum of 5.1 inches from the edge of the wall.      Code Compliance Research Report CCRR‐0258  Page 21 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 6 ‐ Design Loads for Negative Transverse Wind Load (NichiShake™ Shingles)1,4,7    Siding  5 Fastener  Fasteners per Shake  Sheathing  Type  Allowable Design Pressure  (psf)6 Building  Height (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2 ASCE 7‐10 Ultimate Wind Speed (MPH)36‐1/4"  Width  8‐1/4"  Width    12" Width Exp B Exp C Exp D Exp B Exp C Exp D     6d Double HD MAZE  Coil Nail        2        2        3        7/16" OSB        ‐30.6  15 113 102 93 146 132 120 20 113 99 91 146 128 117 25 113 97 89 146 126 115 30 113 95 88 146 123 113 40 108 93 85 140 119 110 50 105 90 ‐‐ 135 117 108 60 102 89 ‐‐ 132 115 106 Notes:  1. NichiShake™ fiber‐cement shingle siding may only be installed on vertical walls. Fasteners must be installed in a way that does not damage the  board during installation. Where necessary, pre‐drilled holes may be used in combination with hand‐nailed fasteners to avoid damage to the fiber  cement product.  2. ASCE 7‐05 Basic Wind Speeds are based upon occupancy category II, a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (GCpi) equal to +/‐  0.18, and an external pressure coefficient (GCp) equal to ‐1.4. Under ASCE 7‐16, the wind speeds are based on Ke = 1.0.  The effects of topographic features have not been  considered and the wind speed has been limited to 170mph.  3. ASCE 7‐10 and ASCE 7‐16 Ultimate Wind Speeds are based upon a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (GCpi)  equal to +/‐0.18, and an external pressure coefficient (GCp) equal to ‐1.4. Under ASCE 7‐16, the wind speeds are based on Ke = 1.0. The effects of  topographic features have not been considered and the wind speed has been limited to 210mph.  4. The values in this table are based on testing per ASTM E330 and represent the allowable capacity of the siding to resist the wind pressures  associated with the corresponding wind speed.  5. Fastener specifications for those used in testing are outlined in Table 9 of this Intertek CCRR. These specifications may be used by the designer of  record to determine the acceptability of alternative fasteners.  6. Allowable design pressures in highlighted cells have been adjusted based on the listed allowable withdrawal capacity of the tested fastener.  7. Framing and bracing are beyond the scope of this evaluation report.         Code Compliance Research Report CCRR‐0258  Page 22 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 7 – Design Loads for Negative Transverse Wind Load (NichiSoffit™)      Fastener  Spacing (in.) Framing Type Framing  Spacing (in.)  Allowable  Design  Pressure (psf)  Building  Height  (ft)  ASCE 7‐05 Basic  Wind Speed (MPH)2  ASCE 7‐10 Ultimate  Wind Speed (MPH)3    Exp B Exp C Exp D Exp B Exp C Exp D  1‐3/4‐in.‐long Maze  double hot dipped  galvanized ring‐ shank nails (0.125‐ in. shank dia., 0.365‐ in. head dia.)   8   Wood, 2 x 4,  min. specific  gravity 0.42  12    Max. 16‐inch‐ wide panels  ‐84.4  15 170 169 154 210 210 199  20 170 165 150 210 210 194  25 170 161 147 210 208 190  30 170 158 145 210 204 187  40 170 153 141 210 198 182  50 170 149 138 210 193 179  60 169 147 136 210 190 176  MAZE CEM‐6 nail: 2  in. long, 0.278 in.  dia. head, 0.119 in.  dia. shank  6  Wood, 2 x 4,  min. specific  gravity 0.42  16    Max. 24‐inch‐ wide panels  ‐70  15 170 155 141 210 200 181  20 170 150 137 210 194 177  25 170 147 134 210 189 174  30 170 144 132 210 186 171  40 164 140 129 210 180 167  50 158 136 127 205 176 163  60 154 134 125 199 173 161  1‐1/2‐in.‐long 4d  hot dipped  galvanized ring‐ shank nails (0.120‐ in. shank dia., 0.219‐ in. head dia.)    8    Wood, 2 x 4  min. specific  gravity 0.42  24    Max. 16‐inch‐ wide panels  ‐37.6  15 124 113 103 161 146 132  20 124 110 100 161 142 129  25 124 107 98 161 139 127  30 124 105 97 161 136 125  40 119 102 94 154 132 122  50 116 100 92 149 129 119  60 113 98 91 146 126 117  6d lap siding nails  (0.12‐in shank dia.,  2‐in. long, 17/64‐in.  head dia.)  8  Wood, 2x4, min.  specific gravity  0.42  24    Max. 48‐inch‐ wide panels  ‐18.3  15 ‐‐ ‐‐ ‐‐ 109 ‐‐ ‐‐  20 ‐‐ ‐‐ ‐‐ 109 ‐‐ ‐‐  25 ‐‐ ‐‐ ‐‐ 109 ‐‐ ‐‐  30 ‐‐ ‐‐ ‐‐ 109 ‐‐ ‐‐  40 ‐‐ ‐‐ ‐‐ ‐‐ ‐‐ ‐‐  50 ‐‐ ‐‐ ‐‐ ‐‐ ‐‐ ‐‐  60 ‐‐ ‐‐ ‐‐ ‐‐ ‐‐ ‐‐  #8 x 1‐1/4‐in. self‐ piercing lath screws 8 No. 20 gage  steel  24    Max. 48‐inch‐ wide panels  ‐21.6  15 96 87 ‐‐ 124 113 ‐‐  20 96 ‐‐ ‐‐ 124 110 ‐‐  25 96 ‐‐ ‐‐ 124 107 ‐‐  30 96 ‐‐ ‐‐ 124 ‐‐ ‐‐  40 92 ‐‐ ‐‐ 119 ‐‐ ‐‐  50 89 ‐‐ ‐‐ 115 ‐‐ ‐‐  60 87 ‐‐ ‐‐ 113 ‐‐ ‐‐       Code Compliance Research Report CCRR‐0258  Page 23 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 7 ‐ Continued      Notes:  1. NichiSoffit™ sheets may only be installed on soffits. Fasteners must be installed in a way that does not damage the board during installation.  Where necessary, pre‐drilled holes may be used in combination with hand‐nailed fasteners to avoid damage to the fiber cement product.  2. ASCE 7‐05 Basic Wind Speeds are based upon occupancy category II, a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (GCpi) equal to +/‐  0.18, and an external pressure coefficient (GCp) equal to ‐1.4.  The effects of topographic features have not been considered and the wind speed has been limited to  170mph.  3. ASCE 7‐10 and ASCE 7‐16 Ultimate Wind Speeds are based upon a wind directionality factor (Kd) equal to 0.85, an internal pressure coefficient (GCpi)  equal to +/‐0.18, and an external pressure coefficient (GCp) equal to ‐1.4. Under ASCE 7‐16, the wind speeds are based on Ke = 1.0.  The effects of  topographic features have not been considered and the wind speed has been limited to 210 mph.  4. The values in this table are based on testing per ASTM E330 and represent the allowable capacity of the siding to resist the wind pressures  associated with the corresponding wind speed.  5. Fastener specifications for those used in testing are outlined in Table 9 of this Intertek CCRR. These specifications may be used by the designer of  record to determine the acceptability of alternative fasteners.  6. Allowable design pressures in highlighted cells have been adjusted based on the listed allowable withdrawal capacity of the tested fastener.  7. Framing and bracing are beyond the scope of this evaluation report.             Code Compliance Research Report CCRR‐0258  Page 24 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 8 – Design Loads for Negative TAS 202 and TAS 203 Transverse Load (Florida Building Code)          Notes:  1. NichiPanel products may only be installed on vertical walls. NichiSoffit may only be installed on soffits. Fasteners must be installed in a way that  does not damage the board during installation. Where necessary, pre‐drilled holes may be used in combination with hand‐nailed fasteners to avoid  damage to the fiber cement product.  2. The values in this table are based on testing per TAS 202 and 203 and represent the allowable design pressures of the siding.  3. Framing and bracing are beyond the scope of this evaluation report.  Siding Type  And Nominal  Thickness (in.)  Framing Material Fastening  Method Fasteners and Fastening  Allowable Design Pressure (psf)  NichiBoard up to 9.25”  width (5/16” thick)  2x4 S.P.F. studs  16” o.c.  5/8” APA Plywood  FACE  Nail  MAZE 8d CEM‐8 nail (2‐1/2 in. long, 0.279 in. dia.  head, 0.123 in. dia. shank) through plywood into  studs 16 in. o.c.  ‐85 psf  NichiPanel  (5/16”)  2x4 S.P.F. studs  16” o.c.  5/8” APA Plywood  FACE  Nail  MAZE CEM‐6 nails (2 in. long, 0.278 in. di. Head,  0.119 in. dia. shank) through plywood into studs  every 6 in. perimeter and field  ‐75 psf  NichiStaggered/  NichiStraight  (5/16”)  2x4 S.P.F. studs  16” o.c.  5/8” APA Plywood  BLIND  Nail  MAZE 8d CEM‐8 nail (2‐1/2 in. long, 0.279 in. dia.  head, 0.123 in. dia. shank) through plywood into  studs 16 in. o.c.  ‐70 psf  NichiSoffit up to 24” width  (1/4” thick)  2x4 S.P.F. studs  16” o.c.  FACE  Nail  MAZE CEM‐6 nails (2 in. long, 0.278 in. dia. head,  0.119 in. dia. shank) into studs every 6 in.  perimeter and field  ‐70 psf  Code Compliance Research Report CCRR‐0258  Page 25 of 25  130 Derry Court • York • Pennsylvania • 17406  intertek.com/building  PCA-101 Version: 6 April 2017 Table 9 ‐Specifications of Tested Fasteners        Siding Fastener    Length  (in)  Head  Diameter  (in)  Shank  Diameter  (in)    1,2,3 Material    5 Siding Type  Minimum  Fastener Penetration  into Material (in)  Fastener  Withdrawal  Value (lbs)            6d Double HD MAZE Coil  Nail          2          0.237          0.099      SPF  NichiPanel™  1 11/16 42.2  NichiBoard™(Face) 1 3/8 34.4 NichiBoard™(Blind) 1 11/16 42.2 NichiStraight™/  NichiStaggered™    13/8    34.4    DF  NichiBoard™(Face) 1 3/8 53.1 NichiBoard™(Blind) 1 11/16 65.2   7/16" OSB  NichiStraight™/  NichiStaggered™    7/16    16.9  7/16" OSB  NichiShake™  7/16 16.9    2.5    0.236    0.097    SPF  NichiBoard™(Face) 1 7/8 45.9 NichiBoard™ (Blind)  2 3/16 53.6      6d Ring Shank Double HD MAZE  Coil Nail        2        0.233        0.105  SPF    7/16" OSB    SYP  NichiFrontier™ (Face)  NichiFrontier™ (Blind)  11/8  19/16  29.8  41.4  NichiStraight™/  NichiStaggered™  7/16   17.9        8d Masonite Siding Nails 2.5  0.313  0.118 SPF  NichiPanel™  2 3/16 65.2    Double HD MAZE Asphalt  & Fiberglass Shingle Nail      1.75      0.365      0.125  SPF  NichiBoard™ (Face)  1 1/8 35.5  NichiBoard™(Blind) 1 7/16 45.4 SYP NichiBoard™(Blind) 1 7/16 70.1   7/16" OSB  NichiBoard™ (Face) 7/16 21.3  NichiBoard™ (Blind) 7/16 21.3  Grabber #8 Flat Wafer  Head Screws6 1.625  0.406  0.166  SPF  NichiPanel™  1 5/16 85.0  20GASteel NichiPanel™ ‐‐ 88.3    Aerosmith Fastening  Systems, VersaPin7    1.5    0.301    0.106    20 GA Steel  NichiPanel™ ‐‐ 94.7  NichiBoard™ (Face) ‐‐ 94.7  NichiBoard™(Blind)‐‐ 94.7 1.375  0.251  0.107  20 GA Steel  NichiPanel™ ‐‐ 94.7    #8‐18 Wafer Head ROCK‐ ON™  Screws8    1.625    0.395    0.162    20 GA Steel    NichiStraight™/  NichiStaggered™    ‐‐    95.0    Aerosmith Fastening  Systems, SurePin9    1.25    0.300  0.145  Concrete  Block NichiBoard™ (Face) 3/4 233.1    2    0.300    0.145    Concrete  Block  NichiBoard™ (Blind)  1 1/8 233.8  NichiStraight™/  NichiStaggered™    11/8    233.8  Notes:  1. SPF (Spruce‐Pine‐Fir) framing material is assumed to have a Specific Gravity of 0.42 or greater.  2. DF (Douglas Fir) framing material is assumed to have a Specific Gravity of 0.5 or greater.  3. OSB sheathing material is assumed to have a Specific Gravity of 0.5 or greater.  Where fasteners are installed through OSB sheathing into SPF  studs, a Specific Gravity of 0.42 shall be assumed for the entire fastener penetration depth.  4. SYP (Southern Yellow Pine) framing material is assumed to have a Specific Gravity of 0.5 or greater.  5. Alternative fasteners must meet the minimum head and shank diameters listed in Table 8.  The required length and withdrawal capacity shall be determined  by the design professional of record in accordance with the requirements of Table 3. 4. 5. 6, and 7 of this Intertek CCRR.  6. Fastener pull‐out capacity based on manufacturer (Grabber Construction Products, Inc.) technical data sheet and a safety factor of 3.  7. Fastener pull‐out capacity based on PEI Product Report PER‐06014 and a safety factor of 3.  8. Fastener pull‐out capacity based on ITW Buildex and Illinois Tool Works, Inc. Product Report No. 02722 and a safety factor of 3.  9. Fastener pull‐out capacity based on PEI Product Report PER‐07021 and a safety factor of 5.